2
Ambulatory reflux monitoring is the only test that allows for determining the presence of abnormal esophageal acid exposure, reflux frequency and symptom association with reflux episodes 1 Combining impedance and pH monitoring improves the detection and characterization of GERD. The frequency, duration, clearance and extent of reflux can be evaluated 2 The advantages of 24-hour pH-impedance include the ability to simultaneously assess the adequacy of acid suppression, analyze persistent symptom association with acid or non-acid reflux despite heavy acid suppression, and measurement of reflux episode frequency 3 The Digitrapper® pH-Z recorder with combined pH-impedance provides total reflux monitoring, allowing you to differentiate acid and non-acid reflux in patients with an array of symptoms. Combined pH-impedance monitoring

Given Imaging Digitrapper pH-Z monitoring

  • Upload
    acertys

  • View
    321

  • Download
    5

Embed Size (px)

DESCRIPTION

 

Citation preview

Page 1: Given Imaging Digitrapper pH-Z monitoring

Ambulatory refl ux monitoring is the only test that allows for determining the presence of abnormal esophageal acid exposure, refl ux frequency and symptom association with refl ux episodes1

Combining impedance and pH monitoring improves the detection and characterization of GERD. The frequency, duration, clearance and extent of refl ux can be evaluated2

The advantages of 24-hour pH-impedance include the ability to simultaneously assess the adequacy of acid suppression, analyze persistent symptom association with acid or non-acidrefl ux despite heavy acid suppression, and measurement of refl ux episode frequency3

The Digitrapper® pH-Z recorder with combinedpH-impedance provides total refl ux monitoring, allowing you to di� erentiate acid and non-acid refl ux in patients with an array of symptoms.

Combined pH-impedance monitoring

Page 2: Given Imaging Digitrapper pH-Z monitoring

References1Katz et al. Am J Gastroenterol 2013;108:308-328.2Shay et al. Am J Gastroenterol 2004;99(6):1037-1043.3Mainie et al. Gut 2006;55:1398-1402.

Digitrapper pH-Z recorder with combined pH-impedance provides total refl ux monitoring

Dual capability: pH-impedance or pH only

Compact size: light weight (150 gram)

Direct data upload with USB cable

Easy to clean protective carrying case

Easy to use

Fast calibration process

VersaFlex® refl ux catheters set the worldwide standard for reliable pH and pH-impedance measurement and patient comfort

Many confi gurations of pH and pH-impedance catheters

Di� erent diameters available (4.7, 6.0 and 6.4 Fr)

Internal reference

Antimony sensor technology

Latex-free

X-ray visible

Easy intubation due to catheter design

AccuView™ analysis software provides all tools needed to analyze an ambulatory refl ux study

Option to upload either pH or pH-impedance studies

pH-impedance line trace or contour mode available for more convenient study analysis

Backward compatibility: allows for the import of existing studies created with most of the previous software versions (Polygram Net®,GastroTrac®, RAPID® pH)

Copyright ©2001-2013 Given Imaging Ltd. GIVEN, GIVEN & Design, PILLCAM, PILLCAM & Logo, RAPID, RAPID ACCESS, BRAVO, BRAVO PH SYSTEM, DIGITRAPPER, MANOSCAN, MANOSHIELD, MANOVIEW, GASTROTRAC, GEROFLEX, VERSAFLEX, ACCUTRAC, ACCUVIEW, POLYGRAF ID, SMARTPILL, MOTILIGI, SMARTBAR, and THE MEASURE OF GI HEALTH are Trademarks and/or Registered Trademarks of Given Imaging Ltd., its subsidiaries and/or a� liates in the United States and/or other countries. All other company or product names are the trademarks or registered trademarks of their respective holders. All rights not expressly granted are reserved.

5-001-887

Digitrapper pH-Z Recorder

VersaFlex Catheter

AccuView Contour Mode

AccuView Line Trace Mode