69
GEWINN Infra LLP – Company Profile

GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

GEWINN Infra LLP – Company Profile

Page 2: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Introduction

A. GEWINN Infra LLP

B. Head Office – Mumbai

C. Representative offices :

1. Pune

2. Chennai

3. Bangalore

D. Deals in Safety Products & Projects

Page 3: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

We offer:

• Products

a. Innovative Safety Products

i. BONPET – Automatic Fire Extinguisher

ii. Shield – Fire Extinguisher (ABC&F Type)

iii. Fire Trolley – Emergency Fire Fighting System

iv. ELSA, Singapore – Water Leak Detection System

• Projects

a. Fire Suppression Tubing System

b. iBMS in Data Centers

i. Fire Alarm System v. CCTV

ii. Fire Suppression System (FM200 / Novec 1230) vi. Water Leak Detection System

iii. Aspiration System (VESDA) vii. Rodent Repellant

iv. Access Control viii. BMS Integration

Page 4: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

The Need For Rapid Fire Extinguishment - RFE

1

TIME POWER EQUATION

INITIAL STAGE CRITICAL STAGE BLAZE STAGE

TE

MP

ER

AT

UR

E (

in d

eg

re

es

)

50

100

1000

Page 5: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Fire Extinguishment using Water

• The best way to remove heat is to dump water on the fire but,

depending on the type of fire, this is not always the best option.

• The most common agent is water; however, it cannot be used for

class B or C fires because it is conductive.

• Although only effective on only Class A fires, they have the

advantage of being inexpensive to operate and causing minimal

damage and cleanup.

• Water extinguishers or APW extinguishers (air-pressurized water)

are suitable for class A fires only.

• Water cannot be used on grease fires, electrical fires or class D fires

- the flames will spread and make the fire bigger!

• FIRE RE-IGNITION RISK IS HIGH

Page 6: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

6

Fire Extinguishment with X Fire Pro

X-Fire Pro, the most powerful fire-fighting liquid is

Extinguishing time and re-ignition

Puts out fire at a record-breaking time in seconds

No re-ignition effect

• Extensive Coverage

X-Fire can be used for A, B, C, E and F classes of fire.

Eco-friendly

Consumes as less as only 3/4 of water usually used in extinguishing fire

Harmless on skin Non toxic Bio-degradable Stain-free on any surface

Page 7: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

7

Working Principle of X Fire Pro

• Based on Fire Triangle, the combustion process requires three

factors: fuel, heat and oxygen.

• X-Fire extinguishing liquid affects the burning zone in three

ways namely:

• Producing extreme cooling effect

• Emitting of oxygen from fire volume

• Spreading a thin film type liquid layer preventing

further re-ignition

• X-Fire liquid has a shelf life of 10 years.

Page 8: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Working Principle of X-FirePro Extinguishing Liquid

• X-Fire Pro owes its extinguishing efficacy to the joint actuation of 4 main effects:

• Smothering - X-Fire Pro displaces the oxygen

thus producing a smothering effect.

• Cooling: X-Fire Pro which causes instant deep cooling

effect thereby reducing the heat radiation drastically. This

action minimizes the effect of 3rd degree burns.

• Attenuation: X-Fire Pro absorbs a great amount

of radiant heat, thus, avoiding re-ignition and fire re-lapse.

Page 9: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Automatic Fire Extinguisher - BONPET

Page 10: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Automatic fireextinguishing Mobile Extinguishing Dilution with water

How to use

Page 11: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

The BONPET fire extinguisher ampoule's automatic activation

What happens if the fire breaks out in a closed area protected by BONPET?

Due to fire the temperature increases and as a result of it the extinguisher

liquid also gets warm and expand in the ampoule. When the temperature of

the liquid gets 85C°+/- 5C° it is converted into vapour and as a result of the

changing of the liquid state pressure is generated/created which breaks the

glass into pieces. The vapour spurts in the area starting endotherm

processes which take energy/power from the fire, thus dousing the fire

instantaneously

How it works

Please play the Video

Page 12: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Advantages of BONPET System

• High efficiency by extinguishing A, B, C and F types of fire

• 10 years warranty, No refilling cost

• Used as a Hand grenade

• The extinguishing liquid mixed with water can be used for Big Fires

• The installation is simple, necessary just 2 screws

• Work even in extreme weather conditions (from -23 C to 80 C) & operates reliably

• Takes up very little place

Page 13: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Advantages of BONPET System

• Doesn’t need to lay a cable, power supply or water pipe

• Doesn’t need any maintenance

• It can be used simply in case of panic situation

• The special glass of the ampoule, broken into pieces without edges

• It doesn't cause damage in electrical systems, machines

• Environment-friendly

• Non toxic effect on humans & other organisms

Page 14: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative
Page 15: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative
Page 16: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative
Page 17: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative
Page 18: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative
Page 19: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative
Page 20: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative
Page 21: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative
Page 22: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative
Page 23: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative
Page 24: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative
Page 25: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative
Page 26: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Comparison of advantages or disadvantages of the different fire classes:A – Common fire (solid flammable substances)C – Flammable gas

B – Burning of flammable liquids (fuel)F - Fire made of vegetable oil and kitchen fat

“The Bonpet ampoule works with great in security in automatic mode of operation by extinguishingELECTRICAL FIRES. It is recommended to install Bonpet ampoules for keep safe and protect electricaldevice, computer centers, transformers and electrical distributor systems (till 60 000 V.)”

HALONS AND

TYPE OF BURNING MATERIAL BONPET WATER THEIR ABC

POWDER SUBSTITUES

A Wooden Material

Paper, Textil, Fabrics

Clothes, Bed linen

Rubber, Celluloid

Hlastic

B

Petrol

Food Greases

Other oils

F

vegetable oil, kitchen fat

very good good bad goodvery good good bad good

very good good bad good

very good good bad good

very good good good good

good bad good good

very good bad good good

very good bad good good

very good bad good good

Comparison

Page 27: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Certifications - BONPET System

Page 28: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Emergency Fire Response Kit - Shield

Page 29: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Facilitate fighting fire from a distance of about 15 – 20 feet indoor

Single Hand Operation and multi-angle discharge facilitating

extinguishment of ceiling height fires

One extinguisher to handle multiple type of fire risk such as Cooking Oil

fire (Class F) & Live Electrical fire (class E), and Class A, B and C.

No Re-ignition of fire as the extinguishing agent forms a thin film on the

surface

Maintenance Free

Bio degradable & negligible residual after use

4 to 6 units of hand-held fire extinguishers are packaged in a strong bag to

facilitate carrying it to the fire spot easily.

Hand Held Fire Extinguisher

Page 30: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Comparison between X-Fire Shield & Conventional Extinguishers

Parameters X-Fire Shield Conventional Extinguishers

Proximity of fighting fire 20 to 25 feet 4 to 7 feet

Ceiling Height Fire Can be used to extinguish

ceiling height fire

Cannot be used to fight ceiling height fire

Ease of operation & training Hand-held Operation with

minimum training

Both hand operation with intensive

training

Multiple threat points

capability

Possible Not possible

Class of Fire A,B,C,E and F A,B and C

Re-ignition Nil Possible

Maintenance Nil Periodic maintenance

Weight 700 gms 3kgs -5kgs

Equipment handling risk Nil Can cause severe damage to the user and

even fatality

Discharge time 30 seconds per Shield 8 seconds

Residue Negligible Noticeable

Page 31: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Certificates & Testimonials

Certifying Agency

TUV, Lloyds,

Underwriter’s Laboratories

Register for Shipping

National Emergency Directorate

Institute of Quality and Metrology

Ministry of Defense

Administration for Civil Protection and Disaster Relief

31

Page 32: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Monday, June 13, 2016 32

Application Areas

Segments Segments

IT Parks Warehousing

Shopping Malls Manufacturing

CollegesSEZ’s

Hospitals Hotels

Page 33: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Emergency Fire Fighting System – Fire Trolley

Page 34: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Emergency Fire Fighting System (Fire Trolley)

Page 35: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

• World’s first Battery OR Petrol Engine operated Emergency Fire Fighting System.

• Would replace 45 conventional extinguishers

• High pressure diaphragm pump with a flow rate of 25 liters per minute

• System capacity of 150 liters would provide 6 minutes of fire fighting equivalent to 45 conventional extinguishers

• Ideal for facilities without sprinkler or hydrant for Emergency Fire Response

• Can lance a distance of 40 feet as against 3 to 5 meters by conventional extinguisher

• Both jet type as well as mist type of spraying is available

• Trolley mounted provides mobility

• Equipment warranty of 5 years and Liquid performance warranty of 7 years

Details of Emergency Fire Fighting System – Fire Trolley

Page 36: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Automatic Fire Suppression Tubing System

Page 37: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Automatic

Fire

Suppression

Tubing

System

Page 38: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Fire Suppression Systems provide Cost-Effective, Stand-Alone,

Automatic Fire Suppression Systems for your Critical Equipment,

Electrical/Technical Systems and various types of enclosures.

The effectiveness of a genuine Firetrace System, happens by utilizing

the proprietary Firetrace Detection Tubing (a Linear Pneumatic Heat

Sensor), which detects a fire due to precise temperature sensitivity,

allowing our systems to react quickly and effectively.

This unique detection can be run through the smallest or most

complex enclosures to ensure detection is always close at hand.

Automatic Fire Suppression Tubing System

Page 39: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

The heart of the system is the Linear Heat Sensitive pneumatic polymer tubing. It

is connected at one end to a Extinguishing Agent Container, which the rest runs

through the risk area, in a predetermined manner. When the flame touches the

tubing and it reaches a temperature of 67 Deg. C, the tubing bursts at it hottest

point (which is nearest to the most vulnerable part of the fire), thus forming a

nozzle .

The pneumatic mechanism then triggers the valve of the extinguisher & sprays

the agent out directly into the fire, thus dousing the fire quicker than any other

technique on the market.

This path breaking system, is entirely automatic, and once installed, requires no

human help. Thus making it the method of choice for “Localized environments”,

or areas which are cordoned off or have an enclosed area (such as panels,

servers..)

Automatic Fire Suppression Tubing System

Page 40: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

DIRECT RELEASE SYSTEMS

Firetrace’s fire protection – direct release systems utilize the

tube as both the “detection device” and “suppressant delivery. As the fire

begins, the portion of the tube nearest the point where the most heat is

detected ruptures, forming an effective spray nozzle.

The pressure will then drop as the Firetrace tube releases the entire

contents of the cylinder through the distribution nozzle to effectively

suppress the fire. More than one Firetrace tube can be used enabling the

system to cover more area. Our fire suppression systems are critical for

safety and protecting your valuable equipments

Automatic Fire Suppression System operates on 2 different Techniques:

Direct & Indirect

Page 41: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

INDIRECT RELEASE SYSTEMS

Once the tubing senses the fire, it ruptures –resulting in a drop of pressure causing the

Indirect Valve to activate

This diverts flow from the detection tube to the larger outlet ports

Then the fire suppression system kicks in – the Extinguishing Agent is discharged from the

cylinder through the diffuser nozzles, flooding the area in a proprietary mix of fire

extinguishing chemicals, effectively suppressing the fire quickly & thoroughly

This system is typically used in larger areas that require a high volume of Extinguishing

Agents, to effectively suppress the fire

Multiple diffuser nozzles may be added to meet the specific Application / requirements

Automatic Fire Suppression System operates on 2 different Techniques:

Direct & Indirect

Page 42: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Entirely automated , does not require any external power supply , thus it functions

perfectly in case an absence of electricity

Instant detection and instant suppression, without any Human involvement

The system is always ready to respond. Hence there is no downtime

Uses Novec 1230,DuPont FE-36 , NAF P IV , NAF S 125 , HCFC 123 and Co2

Flexible tubing allows protection of areas that were otherwise impossible to protect

Simple design. The system gets installed in a few hours, which means minimal labour

and downtime

Rugged design offers outdoor and indoor variants of the tube, and it can withstand

harsh conditions where other types of systems might be rendered inadequate.

Advantages

Page 43: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Installations

Page 44: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Installations

Page 45: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Early Warning Liquid Leak Detection System

Page 46: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Our Expertise and StrengthEarly Warning Liquid Leak Locating Systems

ELSA (Early Leak System Apparatus)

Specialized in Liquid Leak Detection and Locating Systems.(Liquids = water, bases, acids)

Only manufacturer to offer ASIC (Application Specific Integrated Component)

design solution with unique feature – Fail- Safe Loop Back.(Also known as Class A Wiring which is commonly use for Fire Alarm system).

All Control Panels have a Sensitivity adjustment which is easily control at site tothe sense different amount of liquid at sites and to meet various requirement.

Flexible and Customized System solution tailored to individual needs.(eg: custom length of sensing cable no wastage )

No compromise in our Services and Product Quality.

Wide coverage Sales network with local offices or partners in major cities.

Our Expertise and StrengthEarly Warning Liquid Leak Locating System

Page 47: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

3L-TP/12 (12.1 Inch Touch Panel).• Pin-Point Leak Location precisely , tolerance is +/1m .

3L-SP/DP (Supervise Panel): Monitor up to 99 units of 3L-AP/3L-DP /3L-NDP• (3L-SP/DP + 3L-AP/3L-DP/3L-NDP) Systems able to monitor up to an accumulated

Sensing Cable length of 20Km (200m x 100 units).

3L-AP: Advanced Locating Panel + LCD display• 2 x Relays (Leak); 1 x Relay (Cable Break)

optional : (1) Modbus TCP/IP (2) RS485 (3) 4~20mA analogue output (192m)• Sensing Cable Length – up to 200m per module.

3L-DP: (Locating Panel in M36 DIN-Rail or IP65)• 1x Relay (Common Alarm ) and RS485 Communication.• Sensing Cable Length – up to 200m per module.• Visual Alarm by LED light indicator.• NOTE : 3L-NDP addressable module available upon request.

3L-NP: (Non-Locating Panel in M36 DIN-Rail or IP65)• 1 x Relay (Common Alarm)• Sensing Cable Length – up to 60m per module.

• Alarm by Buzzer and LED light indicator

Product at a Glance – Control PanelEarly Warning Liquid Leak Locating System

Page 48: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Product at a Glance – Sensing CableEarly Warning Liquid Leak Locating Systems

3L-LS:

Application:Diameter size:Continuity wires:Sensing wires:Carrier:Fire resistance:

Water and slightly-corrosive conductive liquids.6mm average.White & Red insulated with flame-retardant polymer.2 x Black wires, semi-conductive polymer.Flame-retardant polymer material with greenish color in high visibility.Non-flame propagating and self-extinguishing.

3L-AS:

Application:Diameter size:

Highly-corrosive conductive liquids such as 100% Sulfuric Acid.6mm average.

Continuity wires: White & Red insulated with fire-resistant fluoropolymer.Sensing wires:Carrier:Fire resistance:

2 x Black wires, semi-conductive fire-resistant fluoropolymer.Fire-resistant fluoropolymer material with yellowish color in high visibility.UL910 (NFPA 262), highest Fire/Smoke standard.

Sensing Cable and Joints offer “Cut to Length” cable in Hot-Shrink tube or Male/Female connectors. Ultra sensitive sensing cable (e.g.Dew Point appln) available upon request.

Product at a Glance – Sensing CableEarly Warning Liquid Leak Locating System

Page 49: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

3L-TP/12 – 12.1 Inch Touch PanelEarly Warning Liquid Leak Locating Systems

Pin-Point Leak Location Precisely, tolerance +/-1m.(indication by RED DOT).

History/Event Log : 5,000 events.

“Freezing” of selected zone(s) during maintenance/repairand no fault message generated.

Readily connect to GSM modem / dialer for SMS fault notification

Modbus/TCP option available.

Ability to Zoom-In onto each floor plan.

Varies sizes of LCD monitor available upon request.

3L-TP/12-12.1 inch Touch PanelEarly Warning Liquid Leak Locating System

Page 50: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

3L-SP/DP – Supervising PanelEarly Warning Liquid Leak Locating Systems

• Monitor up to 99 units (external) :either 3L-AP or 3L-DP or 3L-NDP.

• Max. accumulated length :sensing cable up to 20,000m (200m x 100).

• LCD display :4 lines English characters. Each zone isprogrammable by software (up to 35 characters).

Event –Log (896 time-stamped events stored)

Failed-Safe Loop Back Feature (class A wiring system) :Continue to detect leak if there is a cable break

Sensitivity can be adjusted manually.

Communication interface with BMS/EMS2 x Dry contact relay for leaks2x Dry contact relay for cable-breakHigh Level interface protocol : RS485/Modbus

3L-SP/DP – Supervising PanelEarly Warning Liquid Leak Locating System

Page 51: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

3L-AP – Locating PanelEarly Warning Liquid Leak Locating Systems

3L-AP (Locating Panel with LCD display c/w Backlight):

• Connect up to 192m (4-20mA) or 200m (RS485) ofsensing cable and 300m of jumper cable.

Precision of Leak Location: +/- 1m

LCD display – 2 x 14 characters to display leakedlocation and cable break

• Continue to detect leak if there is a cable break Failed-Safe Loop Back Feature (class A wiring system).

Sensitivity can be adjusted manually.Optional Features:

Modbus TCP/IP.RS485/Modbus (Open Protocol).4 - 20mA Analog Output.

3x Dry contact relays : 2 x leaks and 1x cable-break signals out

3L- AP – Locating PanelEarly Warning Liquid Leak Locating System

Page 52: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

3L·LS-Sensor (S:) 3L·LS Senso CS2)

i i~ ~

@Red

SEN

@n Bladt

ABLE

3L-AP: Sensing cable (S1, S2,… ,Sn) & Belden (8723) jumper (J1, J2,…,Jn) connectionwith end termination.

Note: J1 ·• J2 1 •••• t- Jn ~ 300 m

S1 + S2 -t- •••• t Sn < 192

m

..3L LS·Seruoi (Sn)

i

t,~

Jumler Jn)\ JumJr (J2)

O @White G~e

SING C

Page 53: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Unique feature – Fail-SafeEarly Warning Liquid Leak Locating Systems

Loop Back

Fail-Safe Loop Back Connection Diagram

When there is a cable break, the sensing cable will be cut into 2 separatesections (S1a & S1b).Either S1a or S1b still can continue to detect Liquid Leakage.

Unique Feature – Fail-Safe Loop BackEarly Warning Liquid Leak Locating System

Page 54: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

3L-DP – Locating ModuleEarly Warning Liquid Leak Locating Systems

• Connect up to 200m of sensing cable and 300m ofjumper cable.

Precision of Leak Location: +/- 1m

Continue to detect leak if there is a cable break Failed-Safe Loop Back Feature (class A wiring system).

RS485/Modbus (Open protocol)

1x Dry contact relay output for leak or cable-break

Sensitivity can be adjusted easily at site.

Typical Application:

• Connect 3L-DP directly to 3L-SP orEMS/BMS with sensing cables to monitorlarge areas or multiple floors.

3L- DP– Locating ModuleEarly Warning Liquid Leak Locating System

Page 55: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

3L-NP – Non-Locating ModuleEarly Warning Liquid Leak Locating Systems

S1+S2+…+Sn <= 60m

J1+ J2+…+ Jn <= 100m

Sensitivity can be adjusted manually.

• 1x Dry contact relay output for leak or cable-break

Typical Application:

• To monitor small room area (typically 20sqm)

where leak can be located easily such as Pantry room,drip trays.

3L- NP – Non-Locating ModuleEarly Warning Liquid Leak Locating System

Page 56: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

3L-NP – Non-Locating ModuleEarly Warning Liquid Leak Locating Systems

3L- NP –Non-Locating ModuleEarly Warning Liquid Leak Locating System

Page 57: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

((

3L-SP

RcLAV

Typical Schematre Drawing using ELSA3bSP + 3L-DP + 3L-AP Panels

with Cablesconnection

Zone 1 : Server Room 1 (Sensor = 20m)

Zone 2 : Pantry Room 1 (Sensor = 18m)

( _,

Belden cable J

Zone 3: CRAC 36-1 (Sensor= 25m)Wall Mount

•Box IP65: 3L-DP

Zone 4: FCU 36-3 (Sensor = Sm)

Interface 13L-SPl1. Leak: Relay/Dry Contact x 2 pis.

2. Cable Break /Power Fail: Relay/Dry Contact x 2 pts,

3. High Level: RS48S/Modbus.

Interface 13L-DPl1. Leak/Cable Break/Power Fail: Relay/Dry Contact x 1 pt.

2. High Level : RS48S/Modbus.

3L- AP – Locating PanelEarly Warning Liquid Leak Locating System

Page 58: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

(3L-TP/12 + 3L-SP/DP + 3L-AP + 3L-DP + 3L-NDP )system

Locating Systems

Project Schematic Drawing

3L-TP/112 + 3L-SP/DP + 3L-DP + 3L - NDPEarly Warning Liquid Leak Locating System

Page 59: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

(3L-TP/12 + 3L-SP/DP) systemEarly Warning Liquid Leak Locating Systems

3L- TP/12 + 3L-SP/DP) systemEarly Warning Liquid Leak Locating System

Page 60: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Accessories PartsEarly Warning Liquid Leak Locating Systems

3L-T/L50: Labeling Tag (Self adhesive) – 50pcs per stack

3L-HDC/2ST : Hold down clips(Self adhesive) – 100pcs per pack

3L-DS(04) : Distance Spacer – 4 meter of “virtual” length

3L- Connectors : Male/Female connector pair

Wall mount enclosure for 3L-DP or 3L-NDP or 3L-NP : - IP 65 rating.(Custom made enclosure box are available upon request)

AccessoriesEarly Warning Liquid Leak Locating System

Page 61: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

3L-DS ( Distance Spacer or Weighted Length)

Economical Solution for monitoring a few Zoneswith just one Control modules (ie: 3L-AP or 3L-DP)

How it works?• A Spacer Module acts as a distance spacer (eg : 4 meter

spacing) to clearly segregate two Zones under monitoringby using this module.

• Each Zone is segregated by marking the distance withthe Tag.

3L- DS (Distance Spacer or Weighted Length)Early Warning Liquid Leak Locating System

Page 62: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Field of ApplicationsEarly Warning Liquid Lek Locating Systems

Data Centers, Computer /Server/ IT Rooms for Banks, Financial centers,Logistics hubs & etc…

Telecommunication Switching Room

Clean Room and Laboratory build in

• Semiconductor Plants

• LCD Manufacturing Plants

• Wafer Fabrication Plants

• Bio-Medical Plants

••

District Cooling/Heating Systems, ACMV (CHILLED WATER PIPING,

Water Treatment Plants

Underground hot water piping

Tunnel

Library & Museum

CRAC, FCU)

Field of ApplicationsEarly Warning Liquid Leak Locating System

Page 63: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Installation at Chemical PlantEarly Warning Liquid Leak Locating Systems

Installation at Chemical PlantEarly Warning Liquid Leak Locating System

Page 64: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Installation at Data CentreEarly Warning Liquid Leak Locating Systems

Installation at Data CenterEarly Warning Liquid Leak Locating System

Page 65: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Sensing Cable – Chemical PipelineEarly Warning Liquid Leak Locating System

Page 66: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Reference: Banking & FinanceEarly Warning Liquid Leak Locating Systems

Client’s Name CountryMalaysia Bangladesh Malaysia Singapore Hong Kong Singapore Hong Kong Bangladesh Singapore Singapore Singapore Bangladesh Korea Bangladesh Malaysia Singapore Vietnam Hong Kong Singapore Hong Kong Hong Kong Hong Kong Korea Singapore Singapore Singapore

••••••••••••••••••••••••••

Alliance BankBank AsiaBank Negara MalaysiaBank of AmericaBank of China InternationalBank Switzerland InternationalBBVA (Banco Bilbao Vizcaya Argentaria)BRAC BankCitibankDBS (Development Bank of Singapore)Deutsche BankHabib BankHyundai SecuritiesIFIC (Int’nal Finance Invest & Commerce)Kuwait FinanceMerrill LynchNam A BankNewedge GroupNoble ResourcesPolaris SecuritiesPrudential Asset ManagementSamsung SecuritiesSeoul Financial CenterVTB CapitalNomuraHSBC@ Mapletree Business City

Reference: Banking & FinanceEarly Warning Liquid Leak Locating System

Page 67: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Reference: Data Centre Providers, IT, Telco & ManufacturingEarly Warning Liquid Leak Locating Systems

Client’s Name CountrySingapore Hong Kong China Indonesia Hong Kong Singapore Singapore Singapore Singapore Korea Singapore Singapore Singapore Taipei China Singapore Singapore Korea Malaysia Singapore Hong Kong Singapore Singapore Singapore Singapore Malaysia

••••••••••••••••••••••••••

Applied MaterialsAsia Tone (AST)Beijing (Asia Pacific) Data centerCyber CSFEricsson LimitedEquinixGlaxo Smith KlineGlobal SwitchGroup Schneider (APC Datacenter Show Room)Hyundai Steel GroupIntel-Micron FlashJPMorganJurong Datacenter (JDD)

MXIC Wafer FabricationKDDIPacnetREC SolarSamsungSeagateSingTel

Plant

SmarTone Mobile CommunicationSilicon LaboratoriesStarhubSun MicrosystemTata Communication ExchangeTelecom Malaysia

Reference: Data Centre Providers, IT, Telco & ManufacturingEarly Warning Liquid Leak Locating System

Page 68: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

Reference: Insurance, Government Buildings & OthersEarly Warning Liquid Leak Locating Systems

Client’s Name• AIA

CountrySingapore Singapore Singapore Singapore Singapore Hong Kong Hong Kong Singapore Singapore Singapore Hong Kong Singapore Kuwait Malaysia China Singapore Brunei Singapore Malaysia Singapore Singapore Singapore Singapore

Changi Prison•••••••••••••••••••••

Changi AirportChangi Water Reclamation Plant (PUB)FreeportHong Kong AirportING GroupLegoMarina Bay Sands (Casino & Resort)Maple Tree Asset ManagementMayer Brown JSM (Johnson Stokes & Master)Ministry of Home Affair

Ministry of Water & ElectricityPadini Holdings

(District Cooling System)

Phoenix Publishing & Media Group (PPMG)Rio TintoShellSingapore District Cooling (Singapore Power)Symphony HouseTemasek PolytechnicThe Singapore FreeportICAP@MBFCBHP Biliton@MBFC

Reference: Insurance, Government Buildings & OthersEarly Warning Liquid Leak Locating System

Page 69: GEWINN Infra LLP Company Profilegewinn.in/doc/gewinnComProfile.pdf · GEWINN Infra LLP –Company Profile. Introduction A. GEWINN Infra LLP B. Head Office –Mumbai C. Representative

GEWINN Infra LLP

21, Asiatic Arcade,

Pokhran Road No. 01,

Vartak Nagar, Thane – 400 606

Maharashtra, INDIA