32
Pure IP-PBX Getting Started for Physical Cards Model No. KX-TDE100 KX-TDE200 Thank you for purchasing a Panasonic Pure IP-PBX. Please read this manual carefully before using this product and save this manual for future use. KX-TDE100/KX-TDE200: PMMPR Software File Version 2.0100 or later

Getting Started for Physical Cards - Panasonic · 1.2 System Connection Diagram ... ü Telephone cable for extension connection: ... on the back board. 12 Getting Started for Physical

  • Upload
    lycong

  • View
    213

  • Download
    0

Embed Size (px)

Citation preview

Pure IP-PBX

Getting Started

for Physical Cards

Model No. KX-TDE100KX-TDE200

Thank you for purchasing a Panasonic Pure IP-PBX.

Please read this manual carefully before using this product and save this manual for future use.

KX-TDE100/KX-TDE200: PMMPR Software File Version 2.0100 or later

Table of Contents1 Before Installation ....................................................................................31.1 Safety Notices ...................................................................................................................41.2 System Connection Diagram ...........................................................................................51.3 Unpacking ..........................................................................................................................6

2 Installation ................................................................................................92.1 Opening/Closing the Front Cover ..................................................................................102.2 Inserting the SD Memory Card to the IPCMPR Card ....................................................112.3 Installing the Option Units .............................................................................................122.4 Installing the Trunk Cards ..............................................................................................142.5 Installing the Extension Cards (DLC8/DLC16/DHLC8/MSLC16/SLC8/SLC16/

CSLC16) ...........................................................................................................................172.6 Connecting Extensions ..................................................................................................172.7 Frame Earth Connection ................................................................................................18

3 Before Programming .............................................................................193.1 Starting the PBX ..............................................................................................................203.2 Connecting the PC ..........................................................................................................213.3 Installing the Maintenance Console ..............................................................................22

4 Programming ..........................................................................................234.1 Programming the PBX ....................................................................................................24

5 Confirming the Connection ...................................................................295.1 Making and Receiving Calls ...........................................................................................30

2 Getting Started for Physical Cards

Table of Contents

Section 1

Before Installation

Getting Started for Physical Cards 3

1.1 Safety NoticesPlease observe the safety notices in this manual in order to avoid danger to users or other people, and preventdamage to property.The notices are classified as follows, according to the severity of injury or damage:

WARNING This notice means that misuse could result in death or serious injury.

CAUTION This notice means that misuse could result in injury or damage to property.

4 Getting Started for Physical Cards

1.1 Safety Notices

1.2 System Connection Diagram

MSLC16(KX-TDA0175)

SLC8(KX-TDA0173)

EXT-CID(KX-TDA0168)

SLC16(KX-TDA0174)

E1(KX-TDA0188)

IP-GW4E(KX-TDA0484)

IP-GW16(KX-TDA0490)

PRI30(KX-TDA0290CE/KX-TDA0290CJ)

PRI23(KX-TDA0290)

BRI4(KX-TDA0284)

BRI8(KX-TDA0288)

T1(KX-TDA0187)

E&M8(KX-TDA0184)

DID8(KX-TDA0182)

PSU-S/PSU-M/PSU-L

(KX-TDA0108/KX-TDA0104/KX-TDA0103)

DLC16(KX-TDA0172)

DLC8(KX-TDA0171)

DHLC8(KX-TDA0170)

LCOT4(KX-TDA0183)

LCOT16(KX-TDA0181)

LCOT8(KX-TDA0180)

CID/PAY8(KX-TDA0189)

CID8(KX-TDA0193)

V-SIPEXT32

V-IPEXT32

CSLC16(KX-TDA0177)

SLTFaxMachine

SLT(DHLC only)

Wireless Phone(DHLC only)

APT(DHLC only)

DPT

Voice Processing System

DSSConsole

PT-interface CS PS

Radio

Amplifier Pager/Speaker

CSIF4(KX-TDA0143)

CSIF8(KX-TDA0144)

CS PS

Private IP Network

Station Message DetailRecording (SMDR)

Router

Batteries

IP-EXT16(KX-TDA0470)

OPB3(KX-TDA0190)

DPH4(KX-TDA0161)

DPH2(KX-TDA0162)

ECHO16(KX-TDA0166)

EIO4(KX-TDA0164)

MSG4(KX-TDA0191)

Doorphone & Door Opener

IP-PT

LAN

External Sensor/External Relay Device

IP Softphone

ISDN BRI LineISDN BRI Line(Digital Trunk)(Digital Trunk)ISDN BRI Line(Digital Trunk)

ISDN PRI LineISDN PRI Line(Digital Trunk)(Digital Trunk)ISDN PRI Line(Digital Trunk)

T1 LineT1 Line(Digital Trunk)(Digital Trunk)

T1 Line(Digital Trunk)

AnalogueAnalogueTrunkTrunk

AnalogueTrunk

E & M LineE & M LineE & M Line

E1 LineE1 Line(Digital Trunk)(Digital Trunk)

E1 Line(Digital Trunk)

TelephoneCompany

Router

PCIP Softphone

LAN

CTI Server

IPCMPR

(Installed by default)

IP-PT SIP Extension

V-SIPGW16

V-IPGW16

Virtual Trunk Slot

Virtual Extension SlotPrivate IP

Network

Mountable Equipment

PC

ITSP*1

Network

DCE*2

(e.g., ADSL

Modem)

Router

WAN

DSP16(KX-TDE0110)

DSP64(KX-TDE0111)

RMT(KX-TDA0196)

ESVM2(KX-TDA0192)

ESVM4(KX-TDA0194)

KX-DT300/KX-T7600 DPT

KX-DT300/KX-T7600DPT

PCKX-DT346/KX-DT343/KX-T7636/KX-T7633 DPT

*1 ITSP: Internet Telephony Service Provider*2 DCE: Data Circuit Terminating Equipment

Getting Started for Physical Cards 5

1.2 System Connection Diagram

1.3 UnpackingCheck the package contents.Main Unit ´ 1CD-ROM (including manuals, etc.) ´ 1

AC Cord*1 ´ 1 Screw A´ 3 (KX-TDE100)´ 4 (KX-TDE200)

Screw B (Black)´ 2 (KX-TDE100)´ 6 (KX-TDE200)

Anchor Plug´ 3 (KX-TDE100)´ 4 (KX-TDE200)

Mini Plug (for pager and musicsource) ´ 4

Ferrite Core (for the IPCMPRcard) ´ 2

for KX-TDE100 for KX-TDE200 SD Memory Card ´ 1

Metal Bracket ´ 1

*1 The type of the AC cord may vary depending on the country/area of use.The KX-TDE100BX/KX-TDE200BX is supplied with 2 types of AC cord. Please use whichever is appropriate for the country/area.In Canada, there is no ferrite core attached to the AC cord.

NoteIn this manual, the suffix of each model number (e.g., KX-TDE100NE) is omitted unless necessary.

6 Getting Started for Physical Cards

1.3 Unpacking

Necessary items (not supplied):ü Telephone cable for extension connection:

Diameter of cable(ø 0.4 mm to ø 0.6 mm) Maximum length of cable

ø 0.5 mm 1128 m for SLT

ø 0.5 mm 720 m for KX-DT300/KX-T7600 series

ø 0.5 mm 229 m for other DPT, APT and DSS Console

The maximum length of the cable may vary depending on the type of cable and installation conditions.ü An RS-232C cross cable or Ethernet straight cable for PC connectionü Connectors (Amphenol/RJ45/BNC) for trunk and extension connections

Note• The Ethernet straight cable should be a 10BASE-T/100BASE-TX CAT 5 (Category 5) or higher cable.• Use a shielded twisted pair cable for the Amphenol connector.• Use a twisted pair cable for the RJ45 connector.

Getting Started for Physical Cards 7

1.3 Unpacking

8 Getting Started for Physical Cards

1.3 Unpacking

Section 2

Installation

Getting Started for Physical Cards 9

2.1 Opening/Closing the Front CoverOpening the Front Cover

1. Insert a flathead screwdriver into the opening (on the left of the screw cover) and unlatch the screw cover.Turn the screw anticlockwise to loosen.

2. Slide the front cover to the right until it stops, then lift the front cover.

Closing the Front Cover1. Hook the front cover onto the shelf (line up the protrusions on the cover with the receptacles on the shelf),

then slide the front cover to the left until it locks.

2. Turn the screw clockwise to tighten, then secure the screw cover.

2

1

10 Getting Started for Physical Cards

2.1 Opening/Closing the Front Cover

2.2 Inserting the SD Memory Card to the IPCMPRCard

The SD Memory Card contains software for all the processes of the PBX and all the customer data.The SD Memory Card must be inserted before startup.

Example: KX-TDE200

IPCMPR Card

SDCARD

2SD

CARD

4 5

SDCARD

SDMemoryCard

3

1

CAUTIONDo not remove the SD Memory Card while power is supplied to the PBX. Doing so may cause the PBX tofail to start when you try to restart the system.

Getting Started for Physical Cards 11

2.2 Inserting the SD Memory Card to the IPCMPR Card

2.3 Installing the Option UnitsSlot Position

Install the power supply unit (PSU) into the PSU slot, and optional service cards into free slots.

KX-TDE100 KX-TDE200

A PSU SlotB Null Slot*1

C Free SlotsD IPCMPR Card*1 Null slot is not available for any optional service card.

CAUTIONTo protect the back board from static electricity, do not touch parts on the back board in the main unit,PSU, and on the optional service cards. To discharge static electricity, touch ground or wear an earthingstrap. Make sure the screws are tightened to earth the card securely.

Installing the Power Supply Unit1. Insert the PSU along the guide rails.2. Push the release lever in the direction of the arrow, so that the PSU engages securely with the connector

on the back board.

12 Getting Started for Physical Cards

2.3 Installing the Option Units

3. Turn the 4 screws clockwise, in the order indicated by the numbers 1 to 4, to fix the PSU.

Guide Rail

Back Board

Release Lever

Screws

1

3 2

4

Installing the Trunk/Extension Cards1. Insert the card along the guide rails.2. Holding the card as shown below, push the release lever in the direction of the arrow so that the card

engages securely with the connector on the back board.3. Turn the 2 screws clockwise to fix the card in place.

Guide Rail

ReleaseLever

Back Board

Screws

Be sure to cover each slot in which no optional service card is installed by using a Blank Slot Cover. For details,refer to "Covering the Blank Slots" in "3.2.7 Installing/Removing the Optional Service Cards" of the InstallationManual.

Getting Started for Physical Cards 13

2.3 Installing the Option Units

2.4 Installing the Trunk CardsLCOT4/LCOT8/LCOT16 Card

Example: LCOT 16 Card

Amphenol

To trunk

Accessories (included): Screws ´ 2User-supplied (not included): Amphenol connector

14 Getting Started for Physical Cards

2.4 Installing the Trunk Cards

BRI4/BRI8 CardExample: BRI8 Card To attach the ferrite core

To NT1

LINE 1 to

LINE 8

RJ45

TX2(-)RX1(-)RX2(+)TX1(+)

When using 1 or 2 cables:

When using 3 or 4 cables:

• For every 4 cables, use 1 ferrite core; aferrite core holds a maximum of 4 cables.

• Attach the ferrite core as close to thecard’s connector as possible.

Accessories (included): Ferrite core(s) ´ 1 (BRI4 card) or 2 (BRI8 card)User-supplied (not included): RJ45 connector

CAUTIONConnect these optional service cards to the trunk through an NT1; do not connect to the U interface of thetrunk directly.

NoticeWhen connecting the RJ45 connector, attach the included ferrite core.

Note• LINE 5 to LINE 8 are for BRI8 card only.• These optional service cards have 100 W of terminal resistance. For use in point to multi-point

connection, the cards must be placed at the end of the bus.

Getting Started for Physical Cards 15

2.4 Installing the Trunk Cards

PRI30/PRI23 CardExample: PRI30 Card To attach the ferrite core

To NT1

To NT1

TX-

RX-RX+

RJ45

TX+

TX+

TX-

BNC (TX)

RX-

RX+

BNC (RX)

For RJ45

120Ω

75Ω

120Ω

75ΩOR

For BNC

5 cm

Accessories (included): Ferrite core ´ 1User-supplied (not included): RJ45 or BNC connectors

CAUTIONConnect these optional service cards to the trunk through an NT1; do not connect to the U interface of thetrunk directly.

NoticeWhen connecting the RJ45 connector, attach the included ferrite core (except in Canada, where the ferritecore is not necessarily required).

Note• In some countries/areas, the PRI30 card must not be connected to the Public Switched Telephone

Network.• Use only 1 type of connector (RJ45 or BNC) for connection of PRI30 card; RJ45 and BNC cannot be

used simultaneously. Set the termination switch to 120 W (default) or 75 W for connector type to beused.

16 Getting Started for Physical Cards

2.4 Installing the Trunk Cards

2.5 Installing the Extension Cards (DLC8/DLC16/DHLC8/MSLC16/SLC8/SLC16/CSLC16)

Example: DHLC8 Card To attach the ferrite core

Amphenol

To extensions

3 cm

Accessories (included): Screws ´ 2, Ferrite core ´ 1User-supplied (not included): Amphenol connector

NoteAttach the included ferrite core to the cable.

2.6 Connecting ExtensionsExample: KX-T7600 Series DPT Pin Assignments

To extension card

RJ11

TO MAIN UNIT

/ PABXDPT and DSS Console

KX-T7000 Series SLT

H L

T R

APT

HTRL

H L

Getting Started for Physical Cards 17

2.6 Connecting Extensions

2.7 Frame Earth Connection1. Loosen the screw.2. Insert an earthing wire (user-supplied).3. Tighten the screw.4. Connect the earthing wire to earth.

To earth

Earthing wire

Screw

WARNING• Connect the frame of the PBX to earth.• Proper earthing (connection to earth) is very important to protect the PBX from the bad effects

of external noise or to reduce the risk to the user of electrocution in the case of a lightningstrike.

CAUTION• For earthing wire, green-and-yellow insulation is required, and the cross-sectional area of the conductor

must be more than 0.75 mm2 or 18 AWG.• The earthing wire of the AC cable has an effect against external noise and lightning strikes, but it may

not be enough to protect the PBX. A permanent connection between earth and the earth terminal ofthe PBX must be made.

18 Getting Started for Physical Cards

2.7 Frame Earth Connection

Section 3

Before Programming

Getting Started for Physical Cards 19

3.1 Starting the PBXCAUTION

• Before touching the System Initialise Switch, discharge static electricity by touching ground or wearingan earthing strap.

• Once you have started the PBX and if you unplug the PBX, do not perform the following proceduresto start the PBX again. Otherwise, your programmed data will be cleared.

• The power supply cord is used as the main disconnect device. Ensure that the AC outlet is locatednear the equipment and is easily accessible.

• Use only the AC power cord included with the PBX for the PSU.

NoticeThe SD Memory Card must be inserted in the SD Memory Card slot of the IPCMPR card before startup.

NoteThe PBX will continue to be powered even if the power switch is turned "OFF".

1. Slide the System Initialise Switch to the "SYSTEM INITIALIZE" position.

System Initialise Switch

SYSTEMINITIALIZE

NORMAL

Power

Supply Unit

RUN Indicator

To AC Outlet

2. Plug the AC power cord into the PBX and an AC outlet, and turn on the PBX. The RUN indicator will flash.3. While the RUN indicator is flashing, slide the System Initialise Switch back to the "NORMAL" position.

Depending on the configuration, initialisation takes about 1 min to 3 min. If successfully executed, theRUN indicator will stop flashing and stay lit.

All data will be cleared and the PBX will be initialised to the default values. The DPTs should show the timeas 01:00.

20 Getting Started for Physical Cards

3.1 Starting the PBX

3.2 Connecting the PCThe Maintenance Console serves as an overall system programming tool for the PBX. The MaintenanceConsole’s Quick Setup lets you easily configure the PBX to receive intercom and trunk calls, as well as applybasic settings such as time and date.

To programme the PBX, connect it to the PC via the MNT or RS-232C port.

PC ConnectionMNT Port

To LAN Port

To COM Port

RS-232C Port

PC

PC

To attach the ferrite core

3 cm

Pin AssignmentsRS-232C (Cross Cable)

Pin No.

2

34

56

78

Pin No.

2

34

56

78

RS-232C PortCOM Port

Pin No.

1

2

3

6

1

2

3

6

Pin No.

LAN (RJ45 Cable)

LAN Port (PC) MNT Port (PBX)

CAUTIONWhen connecting a PC to the PBX via the RS-232C port, it is necessary to keep the following in mind toprotect the system:1. Make sure that both connector cases (frame ground) of the RS-232C cross cable (shielded cable) are

conductive. If they are not conductive, make sure that both connector cases of the cable are firmlyconnected.

2. If this is not possible, connect the frame of the PBX to the frame of the PC using an earthing wire inorder to prevent difference in the electrical potentials.

NoticeWhen connecting a PC to the PBX via the MNT port, a fixed IP address must be assigned to the PC. Forinformation about fixed IP addresses, ask your network administrator.

Getting Started for Physical Cards 21

3.2 Connecting the PC

3.3 Installing the Maintenance ConsoleFor the system requirements of the PC (e.g., operating system, hardware specifications), referto "4.3.1 Installing and Starting the Maintenance Console" in the Installation Manual.

Note• Make sure to install and use the latest version of the Maintenance Console.• The contents and design of the software are subject to change without notice.• Microsoft product screen shot(s) reprinted with permission from Microsoft Corporation.

1. Copy the setup file of the Maintenance Console to your PC.2. Double-click the setup file to run the installer.3. Follow the on-screen instructions provided by the installation wizard.

22 Getting Started for Physical Cards

3.3 Installing the Maintenance Console

Section 4

Programming

Getting Started for Physical Cards 23

4.1 Programming the PBXStarting the Maintenance Console and Assigning the Basic Items (QuickSetup)

When you start the Maintenance Console with the Installer Level Programmer Code and connect to the PBXfor the first time after initialisation (with the factory default setting), Quick Setup will launch automatically. DuringQuick Setup, you will set up the basic items. For details about the basic items, refer to "2.3.4 Quick Setup" inthe Feature Guide.

1. Connect the PC to the PBX with an Ethernet straight cable or RS-232C cross cable.

2. Start the Maintenance Console from the Start menu.

3. "Information before programming" appears.a. Carefully read this important additional information, which includes updates to this and other

manuals.b. Click OK to close this window.

4. a. Enter the Installer Level Programmer Code (default: INSTALLER).b. Click OK.

5. Click Connect.

6. a. Select KX-TDE100/200 from PBX Model.b. Select the LAN or RS-232C tab, depending on the type of PC connection with the PBX.c. Specify the settings as required.

NoteWhen connecting to the PBX for the first time selecting LAN, the IP Address and PortNumber must be set to 192.168.0.101 and 35300 respectively.

d. Enter the system password for installer (default: 1234).e. Click Connect.

7. When country/area data do not match:a. Click OK to replace the country/area data of the PBX. Replacement may take several minutes to

complete.b. Follow the procedure described in "Section 3 Before Programming" and restart the PBX.c. Repeat step 5 to reconnect the Maintenance Console to the PBX.

8. Follow the instructions of the Quick Setup wizard and assign the basic items (Quick Setup).The system menu appears. You may now begin programming the PBX.

24 Getting Started for Physical Cards

4.1 Programming the PBX

Assigning the BRI Setting (Automatic Configuration)1. a. Under Configuration, click Slot.

b. Move the mouse pointer over the BRI card.A menu will be shown under the mouse pointer.

c. Click Ous to set the card to out-of-service status.

2. Click Tool ® BRI Automatic Configuration from themenu bar.

3. a. Click Check to turn on the BRI card.b. Click OK.

4. a. Enter the subscriber number for the desired ports inSubscriber.

b. Click Execute.

NoteNetwork settings are automatically set.

c. Click Check Box of the desired ports.d. Click Data Apply.e. Click Close.

5. a. Under Configuration, click Slot.b. Move the mouse pointer over the BRI card, then click

INS to set the card to in-service status.

Getting Started for Physical Cards 25

4.1 Programming the PBX

Assigning the Incoming Trunk Call DestinationFor analogue trunk users (DIL Setting):

1. Under CO & Incoming Call, click DIL Table & PortSettings.

2. Confirm that the DIL tab is selected.

3. Configure the settings as required.

4. Click OK.

For ISDN trunk users (DDI Setting):

1. Under CO & Incoming Call, click DDI / DID Table.

2. Configure the settings as required.

3. Click OK.

For ISDN trunk users (MSN Setting):

1. Under CO & Incoming Call, click DIL Table & PortSettings.

2. Click the DDI / DID / TIE / MSN tab.

3. Set the Distribution Method of the desired ports toMSN.

4. Click OK.

5. Click MSN Table.

6. Click the MSN tab.

7. Configure the settings as required.

8. Click OK.

26 Getting Started for Physical Cards

4.1 Programming the PBX

Setting an Extension Port to Use a DSS Console1. Under Configuration, click Slot.

2. Move the mouse pointer over the desired extension cardto display the menu of options.

3. Click Ous to set the card to out-of-service status.

4. Move the mouse pointer over the card again, then clickPort Property.

5. For DPT Type, set the Type to DSS and assign theLocation No.

6. Click OK .

7. Under Extension, click DSS Console.

8. Select the desired pair extension number from PairExtension.

9. Assign features to flexible buttons as required.

10. Click OK.

11. Under Configuration, click Slot.

12. Move the mouse pointer over the card to display the menuof options.

13. Click INS to set the card to in-service status.

14. Click Close.

Getting Started for Physical Cards 27

4.1 Programming the PBX

28 Getting Started for Physical Cards

4.1 Programming the PBX

Section 5

Confirming the Connection

Getting Started for Physical Cards 29

5.1 Making and Receiving CallsMaking Calls

To call another extension

Off-hook. Talk.Dial extension number.

extension no.

To call an outside party

Off-hook. Talk.Dial outside phone number.

Enter automatic line access number.

outsidephone no.9 0/

Receiving Calls

Off-hook. Talk.

30 Getting Started for Physical Cards

5.1 Making and Receiving Calls

The KX-TDE100UK/KX-TDE200UK, the KX-TDE100NE/KX-TDE200NE, the KX-TDE100GR/KX-TDE200GR,

and the KX-TDE100CE/KX-TDE200CE are designed to interwork with the:

• Analogue Public Switched Telephone Network (PSTN) of European countries

• Pan-European Integrated Services Digital Network (ISDN) using ISDN basic rate access

• Pan-European Integrated Services Digital Network (ISDN) using ISDN primary rate

access

• ONP 2048 kbit/s digital structured leased lines (D2048S)

Panasonic Communications Co., Ltd./Panasonic Communications Company (U.K.) Ltd. declares that this equipment is in

compliance with the essential requirements and other relevant provisions of Radio & Telecommunications Terminal

Equipment (R&TTE) Directive 1999/5/EC.

Declarations of Conformity for the relevant Panasonic products described in this manual are available for download by

visiting:

http://www.doc.panasonic.de

Contact to Authorised Representative:

Panasonic Testing Centre

Panasonic Marketing Europe GmbH

Winsbergring 15, 22525 Hamburg, Germany

1-62, 4-chome, Minoshima, Hakata-ku, Fukuoka 812-8531, Japan

PSQX4416XA

Copyright:

This material is copyrighted by Panasonic Communications Co., Ltd., and may be reproduced for internal use

only. All other reproduction, in whole or in part, is prohibited without the written consent of Panasonic

Communications Co., Ltd.

Panasonic Communications Co., Ltd. 2007

KK0607CH2108