8
1-1200-EN Gerotor, Gear and Cam Pumps The gerotor, gear and cam pumps in this brochure are lubricant pumps that can be used for a large number of tasks. The drives of gear and gerotor pumps must not be subjected to radial or axial loads. The indicated delivery rates apply to an operating viscosity of 140 mm 2 /s and a back pressure of 5 bars. If the operating viscosities or back pressures deviate from these values, the delivery rate and power requirements will change. Permissible operating viscosity: 20 to 1000 mm 2 /s. Filtering The pumps require filtration of the lubricant for a maximum particle size of 100 µm. If the metering elements, valves, flow moni- tors, etc. as well as the friction points to be supplied require finer filtration, that must be provided for in the delivery line (recom- mended value 25 µm). Gerotor pump 143-011-131 Gear pump ZP1 Cam pump 206-100

Gerotor, Gear and Cam Pumps

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Gerotor, Gear and Cam Pumps

1-1200-EN

Gerotor, Gear and Cam Pumps

The gerotor, gear and cam pumps in this brochure are lubricant pumps that can be used for a large number of tasks.

The drives of gear and gerotor pumps must not be subjected to radial or axial loads.

The indicated delivery rates apply to an operating viscosity of 140 mm2/s and a back pressure of 5 bars. If the operating viscosities or back pressures deviate from these values, the delivery rate and power requirements will change.

Permissible operating viscosity: 20 to 1000 mm2/s.

FilteringThe pumps require filtration of the lubricant for a maximum particle size of 100 µm.

If the metering elements, valves, flow moni-tors, etc. as well as the friction points to be supplied require finer filtration, that must be provided for in the delivery line (recom-mended value 25 µm).

Gerotor pump 143-011-131 Gear pump ZP1 Cam pump 206-100

Page 2: Gerotor, Gear and Cam Pumps

Gerotor, Gear and Cam Pumps

2 1-1200-EN

Gerotor pumpsfor clockwise or counterclockwise rotation, but with constant direction of rotation and delivery

Gerotor pumps are distinguished by quiet running and little pulsation. They have an internally geared delivery elemen t (trochoid gearing).

Delivery rate 1) Max. back Required drive power Suction and Max. suction at 1400 rpm pressure at back pressure pressure port head 2) Direction L1 L2 L3 Order No. [l/min] [bar] [kW] [bar] S / P [mm] of rotation [mm] [mm] [mm] Fig.

143-011-131 0.85 30 0.18 30 G 1/4 1000 right 1 1.7 (at 2800 min-1) 30 0.37 30 143-011-151 2.5 50 0.18/0.37 20/50 G 3/8 1000 left 2 143-011-161 5.25 50 0.37/0.75 20/50 G 1/2 1000 right 18.5 56.3 69 143-011-171 9 50 0.55/1.1 20/50 G 1/2 1000 right 20 64.3 77 3 143-011-181-2 12.5 50 0.75/1.5 20/50 G 3/4 1000 right 22 76.3 89 143-011-500 19 20 1.5 20 G 1 1000 right 4

1) related to an operating viscosity of 140 mm2/s at a back pressure of 5 bars

2) with open delivery line at 1400 rpm

Direction of rotation (viewing on the drive shaft) consider. Order adapters with ports tapped for solderless tube connection separately.

pressure port

suctionport

48

12.5

G1/4

ø6.6 (2×)

30°

8.8

G1/440 3

ø60

ø8 ø36

2

49 24.9

h5 h8h7

P

S

Figure 1

143-011-131

pressure port

suction port

ø56

13.5

ø6.6

(2×)

4

ø74

ø12

ø45

G3/8 3

62 2801750

g5

h8h7

S

P

Figure 2

143-011-151

The shaft drive has to be without any radial or axial load. See also the important product usage information on the back cover.

Page 3: Gerotor, Gear and Cam Pumps

Gerotor, Gear and Cam Pumps

31-1200-EN

Gerotor pumpsfor clockwise or counterclockwise rotation, but with constant direction of rotation and delivery

S

P

suction port

pressure port

ø14

ø88

ø56

300L1L2L3

3ø70

16

0

5

ø6.6 (4×)

45°45°

135°

h8h7

g5

Figure 3

143-011-161, 143-011-171, 143-011-181-2

18ø8.5 (4×)

ø80

ø98

100

G1ø40

25 3

30

19

ø56

ø16

h7g5

pressure port

suction port

h8

S

P

5

45°

Figure 4

143-011-500

Page 4: Gerotor, Gear and Cam Pumps

Gerotor, Gear and Cam Pumps

4 1-1200-EN

Gerotor pump for clockwise and counterclockwise rotation,but for constant direction of delivery with changing direction of drive shaft rotation to DIN 69001, Part 17 A

This pump is especially suitable for direct gear drive.

When the pump is used in systems that do not have an open delivery line, e.g. which have a check valve, safety valve or closed bearings, it is necessary to provide for a venting aid.

Delivery rate Max. per revolution 1) Speed range back pressure Suction head 2) Direction Order No. [cm³] [rpm] [bar] [mm] of rotation Figure

143-011-560 4 200-2000 20 1000 any 5

1) Corresponds to 5.4 l/min at 1400 rpm as related to an operating viscosity of 140 mm2/s at a back pressure of 1 bar.

2) with open delivery line

3

(4×)

ø11

o-ring27.3×2.4

feather keyDIN 6885 – A4×4×16

6.8

16

ø80ø65 ±0.1

41-0.3553115

G1/4

G1/4

ø32

j6

13ø1

2 j6

ø7

SP

Figure 5

143-011-560

The shaft drive has to be without any radial or axial load.

S = suction port P = pressure port

Page 5: Gerotor, Gear and Cam Pumps

Gerotor, Gear and Cam Pumps

51-1200-EN

Gear pumpsfor clockwise or counterclockwise rotation, with constant direction of rotation and delivery

Delivery rate Max. Required at 1400 rpm back pressure drive power Suction head 1) Direction Order No. [l/min] [bar] [KW] [mm] of rotation Figure

ZP12-2 1.2 25 0.18 500 right 6 ZP1

2.5 20 0.18 1000 right 7 ZP1-S1 left

1) with open delivery line at 1400 rpm

Direction of rotation (viewing on the drive shaft) consider. Order adapters with ports tapped for solderless tube connection separately.

85

ø48

ø6.6

(2×)

14

360

G1/449

30°

ø60 3

ø10

G1/4

ø36

90°

2.2

11.2

S

P pressure port

suctionport

f7h7h8

Figure 6

ZP12-2

feather keyDIN 6885 3x3x10

82

327

217

58ø70

0.8

ø5.8 (4×)ø60

M12

×11090°ø6

1 9.1 ø5

0

ø10

11.3

ø19j6

h7

45°

P S

PS

1)

2)2)

1)

Figure 7

ZP1, ZP1-S1

1) ZP1: Direction of rotation right (viewing on the drive shaft)

2) ZP1-S1: Direction of rotation left (viewing on the drive shaft)

S = suction portP = pressure port

Page 6: Gerotor, Gear and Cam Pumps

Gerotor, Gear and Cam Pumps

6 1-1200-EN

Cam pumps for clockwise or counterclockwise rotation,but for constant direction of delivery with changching direction of rotation

With these valveless piston pumps the piston is driven directly via a cam so that only three constantly moving elements are involved.

This configuration results in dependable operation and a long service life.

The fluids to be pumped must have enough lubricity for the pump to lubricate itself.

Ext. suction Delivery rate 1) Max. back Permissible Suction and delivery at 1500 rpm pressure speed range head 2) tube diam. Direction Order No. [l/min] [bar] [rpm] [mm] [mm] of rotation Model Figure

206-100 1.3 5 50-1500 1000 8 any with shaft butt 8 206-100-5 2.6 3 10 9 206-100-10 1.3 5 50-1500 1000 8 any with slotted coupling 10 206-100-50 2.6 3 10 11 1) The delivery rate depends on the speed, viscosity, suction and deliveryhead (cf. diagram).

2) With open delivery line; the suction head depends on the speed and viscosity.

Order adapters with ports tapped for solderless tube connection separately.

3

150010005000

1

2

rpm

l/min

I = 206-100 206-100-10

II = 206-100-5 206-100-50

The diagram shows the delivery rate for a suction head of 0.5 m at 3 bars back pressure for a mineral oil with a viscosity of 140 mm2/s.

Page 7: Gerotor, Gear and Cam Pumps

Gerotor, Gear and Cam Pumps

71-1200-EN

M16×1.5P

S

91

Figure 11

206-100-50

108

24

232

4×90°

11.5

12k5

13.614

M14×1.5

6.5

ø63

4194.5

ø6.4

30°

ø50

ø10.4

S

P

10.5

ø25h

9

4

ø36

h9

1.1(4×)

Figure 8

206-100

85

3.44 deep

ø16

6.5 10.5

2115

4.2842

71.5

ø36

h9

M14×1.5

ø8

M35

×1.5

M6

ø25h

9

ø10.4(4×) ø6.4

S

P

H9

+0.1

Figure 10

206-100-10

M16×1.5

91

WAF 19

S

P

Figure 9

206-100-5

Cam pumps for clockwise or counterclockwise rotation,but for constant direction of delivery with changching direction of rotation

S = suction port P = pressure port

Page 8: Gerotor, Gear and Cam Pumps

This brochure was presented by:

Order No. 1-1200-ENSubject to change without notice! (07/2009)

Important product usage informationAll products from SKF may be used only for their intended purpose as described in this brochure and in any instructions. If operating instructions are supplied with the products, they must be read and followed.Not all lubricants are suitable for use in centralized lubrication systems. SKF does offer an inspection service to test customer supplied lubricant to determine if it can be used in a centralized system. SKF lubrication systems or their components are not approved for use with gases, liquefied gases, pressurized gases in solution and fluids with a vapor pressure exceeding normal atmospheric pressure (1013 mbars) by more than 0.5 bar at their maximum permissible temperature.Hazardous materials of any kind, especially the materials classified as hazard-ous by European Community Directive EC 67/548/EEC, Article 2, Par. 2, may only be used to fill SKF centralized lubrication systems and components and delivered and/or distributed with the same after consulting with and receiving written approval from SKF.

SKF Lubrication Systems Germany AG Motzener Strasse 35/37 · 12277 Berlin · Germany PF 970444 · 12704 Berlin · Germany Tel. +49 (0)30 72002-0 · Fax +49 (0)30 72002-111 www.skf.com/lubrication

® SKF is a registered trademark of the SKF Group.

© SKF Group 2009The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.

Further brochures1-9201-EN Transport of Lubricants in Centralized Lubrication Systems