• BUND LINERS • SLURRY LAGOONS • GAS PROTECTION • FABRICATION & COMPONENT MANUFACTURERS • STORMWATER MANAGEMENT SYSTEMS • WATER FEATURES & GEOMEMBRANE LININGS
GeomembranesLINING SOLUTIONS
Keytec Environmental Ltd, Cumberland House, Cumberland Street, Leicester, LE1 4QS
Tel 0116 262 9106 Fax 0116 251 1802 email [email protected]
Welcome to Keytec
www.keytec.co.uk email: [email protected]
“Keytec Geomembrane products can be used in a variety of applications including Golf Courses, Sports Stadia, Shopping Centres, Warehouses, Residential and Commercial environments, plus many more...”
INTRODUCTIONKeytec Geomembranes is a private company, exclusively dedicated to the delivery of quality products and services to the construction and civil engineering industry. We have a wealth of relevant technical knowledge and experience of developing and installing geomembranes and gas protection products. Keytec manufactures gas barriers and components used by the engineering, construction, leisure, and oil and water industries. We also supply and install a wide range of geomembrane-geotextile products that help to protect the environment for the benefit of future generations.
OUR MISSIONKeytec Geomembranes aims to supply and install quality products and services that will benefit our customers and the construction industry.
OUR SERVICESThe company supplies and installs an extensive range of products including: Gas barriers, low and high density polyethylene, EPDM, polypropylene, fpa, pvc, eia, geosynthetic clay liners, adhesive sheet membranes, gas venting systems and geotextiles.
We manufacture Keytec 400 and Keytec multi gas barriers, gas venting systems, pipe sections and steel column cloaks. Our products have the approval of local authority building control, NHBC, the Environment Agency and water companies.
Our accumulated knowledge and engineering expertise, coupled with our enthusiasm for problem solving, enables Keytec Geomembranes to provide an efficient and reliable service, responsive to the needs of our clients.
Call us for a quotation without obligation. We will provide technical support or advice either on site, or from our Leicester office.
KEYTEC 400 GAS BARRIER
KEYFLEX
KEYSEAL
KEYTEC MULTI GAS BARRIER
KEYTEC MULTI GAS BARRIER TAPE SYSTEM
KEYTEC 642
KEYTEC 295
KEYTEC MRC1500
KEYTEC SUDS
KEYTEC GEOMEMBRANES
KEYTEC GEOTEXTILES
KEYTEC PREFABRICATION
CLIENT LIST
04-05
06
07
08
09
10
11
12
13 -14
15
16
17
18 - 19
CONTENTS
Gas Barrier400
Gas Barrier400
COMPOSITION
Scrim reinforced polyethylene and aluminium
MATERIAL SPECIFICATION
PROPERTY UNIT VALUE TEST METHODUnit weight g/m² 415 ASTM D1505Thickness mm 0.46 ASTM D5799Tensile strength k/N/m 9.47 ASTM D 6693.04Methane transmission cm³/h/m² less than 0.005 Oxygen transmission NILMoisture transmission g/m²/day less than 0.01Radon improvement factor 500-1 Puncture resistance N 142.1 ASTM D4833
Keytec 400 can be used in a variety of applications including the protection againt Methane, Radon, CO2 gases and also Hydrocarbon vapours.
www.keytec.co.uk email: [email protected]
Keytec 400 gas barrier: Specification methane and CO²
Keytec 400 gas membrane is loose laid to a prepared substrate. The membrane contains at least 15µ aluminium foil, reinforced with polyester multistrand scrim and encapsulated with polyethylene films. The puncture resistance has a CBR of at least 142N and maximum elongation of 3.3% with a minimum thickness of 0.46mm and a methane transmission of less than < 0.01cm³/m²/h. Keytec 400 is fully hot-air welded and tested for peel and sheer within the application.
KEY FEATURES• Five layer process membrane • Exceeds DPM standards • Extremely low gas transmission • Gas barrier for methane, carbon dioxide and radon
• Weldable with conventional hot air equipment • Aluminium foil core • Meets BS standards for DPC • NHBC approved
j40 FLEXIBLE SHEET TANKING/DAMP PROOF MEMBRANES
110. HARDCORE BEDS: Blind with not less than 50mm of soft sand or pulverized fuel ash and consolidated to provide a smooth bed free of sharp projections.
120. POLYETHYLENE DAMP PROOF MEMBRANE / GAS BARRIER: Manufacturer and reference: Keytec 400by Keytec Geomembranes. Telephone 0116 262 9106 Thickness / gauge: O.46mm
Methane transmission less than 0.005cm³/h/m²
Tensile MD 9.47kn/m
Moisture transmission less than 0.01g/m²/day
The membrane is loose laid to the formation with 100mm overlaps welded by hot air fusion at seams and terminated at the edge of the outer leaf of the structure.
Care must be taken to ensure that the gas membrane is not punctured prior to the casting of the concrete floor slab or screed.
All service entries are sealed with proprietary top-hat sections and heat welded to the gas barrier or adhesive methane membrane in the case of multi-ducts. [Keyflex GMA]
310. WORKMANSHIP GENERALLY:
Materials must be applied with care to provide a completely gas impervious and damp proof membrane.
360. JUNCTIONS WITH PROJECTING DPCs/ CAVITY TRAYS:Adjoining surfaces must be clean and dry. Projecting DPCs/ cavity trays: Lap, fully bond and seal with sheeting.
• Laps (minimum): 100mm. • Bonding/sealing: Manufacturers’ recommendations
370. PIPES, DUCTS AND CABLES:
Preformed collars are recommended for the purpose by the membrane manufacturer.
• Sealing: Fully bond to penetrations and sheeting.
• Completed junctions: Impervious.
Standard Detail
LAP & WELD OR KEYSEAL TAPE
LAP & WELD OR KEYSEAL TAPE
Air Brick & Cranked Sleeve
KEYTEC 400 GAS BARRIER Face Brickwork
Beam & Block Flooring
Clean Lap & Seal with Keyseal Tape
Air Bricks spaced to give min. 3000mm2 per metre of wall. Air Bricks to be spaced at centres no greater than 1.5 metres and 450mm from corners
18mm T & G Mositure Resistant Flooring Grade Chipboard on 125 Micron Polythene Vapour Barrier 25mm Flooring Grade Polythene
PARTY WALL
Vertical Keytec 400 Gas Barrier
2 layers 50mm Polystyrene providing insulation and retaining Keytec 400 Gas Barrier
DPC
Min 150mm LapKeytec 400 GasBarrier Lap &Keyseal Tape
2325
Sla
b - u
/s J
oist
s
2520
fin. fl
oor/fl
oor
100mm Cavity
255mm Joists
British Gypsum Dry Lining
50mm Polystyrene Cavity Wall Insulation
Continuous Cavity Tray
65mm Starter Block
Keytec 400 Gas Barrier across Cavity
Air Bricks & Cranked Sleeve
DPC
Continuous Cavity Tray
Air Brick & Straight Sleeve Beam & Block
Flooring
Beam & Block Flooring
DPC
DPC
Min 150
Min. 150mm Lap Clean & Double Tape using Keyseal Tape
DPC
05
Gas Barrier TapeKEYSEAL
Adhesive Gas MembraneKEYFLEX
An integrity testing service is available for all installations on request and third party accreditation.
Keytec 400 gas barrier can be applied to suspended block and beam floors and ground bearing concrete slab floors.
Industrial Housing
KEY FEATURES• Cold applied membrane • Self adhesive • High puncture resistance • Low vapour transmission • Impervious to radon gas • Low methane permeability
APPLICATION
Cut to size, remove backing paper, apply to substrate. Where applying to a friable surface the application of Keyflex primer is required. Apply by brush or roller, ensure primer is dry before fixing membrane to surface. For detailed application, contact our technical support staff.
SUGGESTED SPECIFICATION
The adhesive gas membrane, Keyflex AGM, must be applied to the substrate with 150mm overlap and contains the minimum gas transmission properties of < 0.03 ml / m² /24h @ atm and where masonry is friable, the substrate shall be primed with Keyflex primer.
COMPOSITIONAluminium foil reinforced bitumen rubber compound sheet, with biaxually-oriented HDPE film to one side.
PRODUCT• Size : 1.05m x 28.6m per roll • Weight : 1.2 Kg / m²• Thickness : 1.00mm • Water vapour transmission : < 0.1 g / m² / 24h ASTM E96• Methane transmission : < 0.03ml / m² / 24h • Radon diffusion coefficient : 5.0 10-14 m /² s NRPB• Puncture resistance : 250N ASTM E154
PRIMERA solution of bitumen in a blend of aromatic and aliphatic hydrocarbon solvents (OEL 100ppm 8 hrs TWA). Coverage rate 5 to 7 m² per litre, less on more porous substrates.
KEY FEATURES• High shear strength • High movement capability • High peel strength • Chemically resistant to dilute acid and alkalis • Available in five widths • Life expectancy, in excess of 20 years
APPLICATION
Optimum performance will be achieved when applied to clean, dry, dust and grease-free surfaces. Excellent adhesion to plastic, wood, metal and masonry. Recommended size application, 100mm & 70mm for polyethylenes, polypropylenes and butyl. 100mm, 70mm & 50mm for gas barriers. 30mm & 15mm radon barriers.
SUGGESTED SPECIFICATION
Keyseal Tape must be applied to a dry surface into a 150mm overlap of the membrane and pressed down firmly to achieve a gas tight seal. The tape should only be applied at temperatures above 5°C.
COMPOSITIONPolybutene, inert fillers and oil with elastomeric backbone, formed into an homogeneous tape carried on a release paper.
PRODUCT• Cross linked butyl compound • Size : 100mm, 70mm, 50mm, 30mm, 15mm• Colour : Black • Contains : No known toxic ingredients. Solvent free• Recommended service temp : -40°C to +110°C • Density : 1.6 g / cm² • Typical test results : Observed @ 20°C Elongation at break 200% • Force compress by 20% : 220N• Paintability : Good • Resistance to mould : Good• Service life (predicted) : 20 + years • Shrinkage : <0.5%• Shear strength : 16.2N • Slump : Nil• Tack : Very good • UV resistance : Very good• Movement accommodation : 15% • Moisture vapour transmission rate : 0.24g/m² 24 hours
06 07
Multi Gas Barrier Tape System
PROPERTY UNIT VALUE TEST METHOD
Thickness µm 300 EN 1849-2 Dimensions (width x length) m 3 x 50 Folded to 1.5m Roll weight kg 42.3 Colour Blue Radon permeability m2/s 4x10-12 CO2 permeability cm3/(m2 xd xbar) 950 DIN 53380-4 Equivalent air layer Thickness (23Cº 0/75%rf) m > 100 EN ISO 12572 Water vapour permeability (23Cº 0/75%rf) g/m/day 0.16 EN ISO 12572 Tensile strength MD N/mm > 24 EN 12311-2 CD N/mm > 21 Tensile elongation MD % > 500 EN 12311-2 CD % > 600 Tear resistance MD N > 75 EN 12310-2 CD N > 85 Nail tear resistance MD N > 190 EN 12310-1 CD N > 220 Resistance to shear of joints N > 200 EN 12317-2 Dimensional stability MD % -0.9 EN 1107-2 CD % +0.5 Puncture resistance N > 141 ASTM D4833
Multi Gas BarrierDPC
Pipe Cap
Sand Blinding(50mm minimum)
Compacted Hardcore
Radon Sump
100mm Pipe
Keytec Multi Gas Barrier continous fully sealed membrane
Keytec Gas Resisting Membrane
Keytec Multi Gas Barrier continous fully sealed membrane
Min 75mm
Min 75m
m
KEYTEC MULTI GAS BARRIER UNDER FLOATING SLAB WITH COLLECTION SUMP & VENT PIPE
NSAI Agrément Certificate 08/0322
Sealing of a structural steel stanchion penetration seal
COMPOSITIONKeytec multi gas barrier consists of self bonding polymer modified bitumen which is covered on one side by a tough multiply cross laminated polythene film and protected on one side by a backing sheet.
PRODUCT• Roll size : 150mm x 20m • Thickness : 1.5mm• Water vapour transmission (25ºC.75% rh) : 0.20g-m² per day• Radon transmission : < 3.2 - 10-10m/s• Radon permeability : < 4.8 - 10-13m/s• Puncture resistance : 220N
Keytec Multi Gas Barrier System can be used for the protection of structures against the ingress of CO2 and Radon gases and as a general purpose DPM.
Keytec multi gas barrier applied to prepared surface
Keytec multi gas barrier tape 150mm wide
SLAB
150mm
Keytec multi gas barrier applied to prepared surface
150mm wide Keyflex Tape
150mm
www.keytec.co.uk email: [email protected] 09
Reinforced Polyethylene Membrane 642
CONSTRUCTIONRaw material reinforcement Polyester multi-split fibreRaw material coating both sides LDPE
A fabric made with polyester reinforcement sandwiched between two polyethylene films.
SUGGESTED SPECIFICATION Keytec 642 is made from low-density polyethylene with 1000 denier polyester scrim reinforcement. The performance values of tensile strength are 24kN/m EN ISO 10319.96 and a drop cone test result in no greater than 8mm.The durability performance to be > 90% UV exposure to BS EN 1224 -2000 and oxidation resistance age test of less than 12% to ISO 13438.
PROPERTY UNIT VALUE TEST METHODUnit weight g/m² 628 BS ISO 965-95Thickness (2 KN/m² pressure) 1.03 BS EN 964-1-95Tensile strength at break MD kN/m 24.7 EN ISO 10319-96 C D kN/m 24.34 EN ISO 10319-96Elongation at strain MD % 33 EN ISO 10319-96 MD % 31 EN ISO 10319-96Trapezoid tear strength MD N 545 A STM D4533-96 C D N 381 A STM D4533-96Puncture resistance N 273.3 A STM D4833Oxidation resistance test age-% 11.58 I SO 13438-2004UV – exposure resistance % 90 BS EN 12224-2000
Keytec 642 is used in the construction of reed beds, lakes, ponds, slurry pits and SUDS.
MATERIAL SPECIFICATION
CONSTRUCTIONRoll size : 1.83m x 150mFabrication to any given size.Contains ultraviolet inhibitors and is suitable for exposed applications.Resistant to Japanese Knotweed.
SUGGESTED SPECIFICATION Keytec 295 is constructed from high density polyethylene tapes coated with low density polyethylene to both faces. It has a mass per unit area of >290gm² and tensile elongation not greater than 24% ASTMD 751.
Polyethylene Coated Woven Polyethylene295
Keytec 295 is suitable for containment and land capping, temporary lining, bio-piles, Japanese Knotweed, wildlife barriers and under pavement drainage lining.
MATERIAL SPECIFICATION
PROPERTY UNIT VALUE TEST METHODUnit weight g/m² 295 ASTM D3776 Thickness (2 KN/m² pressure) 0.6 BS EN 964-1-95Astm tapes 10cm warp 48 ASTM D3776 weft 48 ASTM D3776Tensile grab strength N warp 1180 ASTM D751 weft 1200 ASTM D751Tear strength * (tongue) N warp 300 ASTM D2261 weft 400 ASTM D2261Tensile strength MD kN/m 28 BSEN ISO 10319 CD kN/m 38.6 BSEN ISO 10319Tensile elongation % 23.6 ASTM D751Elongation at strain MD % 14.1 BSEN ISO 10319 CD % 15.4 BSEN ISO 10319Puncture resistance kN 4.13 BSEN ISO 12236Transverse direction mm 33.4 BSEN ISO 12236Scrim colour blackCoating thickness both sides µm black 65.3 ASTM D1777 MOD
www.keytec.co.uk email: [email protected] 11
Reinforced Chemical Resistant Membrane
MRC1500
WHAT IS MRC 1500?MRC1500 is a synthetic reinforced membrane based on a polyester textile which is molecularly coated with a high quality resin. The polyester tissue gives high mechanical properties to the membrane while the coating provides the waterproofing and chemical resistance. The tissue consists of polyester threads. The polyester tissue is firstly impregnated with a resin to avoid all wicking effects; then the tissues are coated with a resin. This resin is an “interethylene polymer resin” which provides the membrane with a high resistance against petroleum products and other chemicals. MRC1500 membrane is very flexible and has a high dimensional stability.
SUGGESTED SPECIFICATION Keytec MRC1500 is a synthetic reinforced membrane bored on a polyester textile which is molecularly coated with a high quality resin. It has a mass per unit area of 1092gm² and a thickness of 0.91mm.
EFFECT OF FLUID ON MEMBRANE - FLUID HAS LITTLE OR NO EFFECTFluid has little or no effect - Acetic acid (5%), Ammonium phosphate, Ammonium hydroxide, Ammonium sulphate, Antifreeze (ethylene glycol), Vinegar (8º), Butanone, Calcium chloride-solution, Calcium hydroxide, Chlorine solution (20%), Clorox (bleaching agent), Diesel, Ethanol, Phosphoric acid(50%), Glycerine, Hydrochloric acid HCI (50%), Hydrofluoric acid HF (5%), Hydrofluoric acid HF (50%), Isopropyl alcohol, Potassium chloride, Potassium sulphate, Kerosene, Magnesium chloride, Magnesium hydroxide, Fertiliser solution, Methanol, Mineral spirits, Sodium acetate solutions, Sodium bisulphate solution, Sodium phosphate, Sodium hydroxide (60%), Nitric acid (5%), Oils: ASTM type 3, animal, vegetable, hydraulic – petroleum, corn, crude, raw linseed, SAE-30, transformer, Terpentine, Water (potable) 23ºc, Water (sea) 23ºc, Zink chloride, Sulphuric acid (50%)
PROPERTY UNIT Thickness mm Weight g/m² Dimensional stability % Tear strength MD N/mm CD N/mm Tensile strength MD N CD N Adhesion Weld N/5cm Hydrostatic Resistance N/cm² Puncture resistance N Bursting strength N Thermal expansion coefficient Mm/mm/ºc Low temperature resistance ºcRoll width mRoll length m
MATERIAL SPECIFICATION
Please view our website for further information
KEYTEC POLYPROPYLENE MEMBRANE
PROPERTY UNIT VALUE TEST METHOD
Thickness mm 1 ASTM D 5199 Density g/m³ .87 ASTM D 1505 Tensile strength at break N/mm 17 ASTM D 1693 Elongation at break % 900 ASTM D 1693 Puncture resistance N 150 ASTM D 4833 Tear resistance N 55 ASTM D 1004
KEYTEC LLDPE MEMBRANE
PROPERTY UNIT VALUE TEST METHOD
Thickness mm 1 ASTM D 5199 Density g/cm³ .94 ASTM D 792 Tensile strength at break N/mm 27 ASTM D 638 Elongation at break % 800 ASTM D 638 Puncture resistance N 250 ASTM D 4833 Tear resistance N 100 ASTM D 1004
CONSTRUCTION
Roll sizes on application. All other types of Geomembrane on application.
All welding Technicians are qualified by TWI to BS EN 13067, approval testing
for plastic welders, via the internationally recognised “Certification Scheme
for Welding Inspection Personnel (CSWIP).
KEYTEC 401 HYDROCARBON (VAPOUR) MEMBRANE
PROPERTY UNIT VALUE TEST METHOD
Thickness mm 0.46 ASTM D 5199 Density g/m² 415 ASTM D 1505 Tensile strength at break MD kN/m 9 ASTM 6693 CD kN/m 8.8 ASTM D 6693 Elongation at break MD % 6.5 ASTM D 6693 CD % 5.7 ASTM D 6693 Puncture resistance N 142.1 Tear resistance MD N 39.3 ASTM D 1004 CD N 38.7 ASTM D 1004
KEYTEC HDPE TEXTURED MEMBRANE
PROPERTY UNIT VALUE TEST METHOD
Thickness mm 1 ASTM D 5994 Density g/cm³ 0.94 ASTM D 1505 Tensile strength at break N/mm 11 ASTM D 6693 Elongation at break N/mm 150/700 ASTM D 6693 Puncture resistance N 320 ASTM D 4833 Tear resistance N 125 ASTM D 1004
Puraflex® HydroCarbon Resistant Membrane
PROPERTY UNIT VALUE TEST METHOD
Thickness mm 0.45 EN 1849-2 Density g/m2 430 EN 1849-2 Tensile strength at break MD MPa 53.4 ISO R 527-3 XD MPa 48.8 ISO R 527-3 Elongation at break MD % 920 ISO R 527-3 XD % 779 ISO R 527-3 Puncture resistance Resistance kN 1.47 EN ISO 12236 Movement mm 140.6 EN ISO 12236 Tear resistance MD N 45.8 ASTM D1004 XD N 45.7 ASTM D1004
Keytec Geomembranes
www.keytec.co.uk email: [email protected] 13
TEST METHODASTM D-751/DIN 53370ASTM D-751/DIN 53370ASTM D-1204/DIN 53377DIN 53515
ASTM D-751 (grab tensile)
ASTM D-715/ASTM D-413ASTM D-751ASTM D-751/D-4833ASTM D-751 (ball trip)ASTM D-696ASTM D-2136
VALUE0.9110920.5 max80077136463302175577 123833471.8 x 10-5 To -35 2.5200
AquaCell Systems - System SelectorSUDSSUDS
For detailed technical information visit www.intesio.co.uk
Specifying Keytec SUDS systems provides the following benefits:
• Significantly reduced flooding risk and compliance with Building Regs and CfSH/BREEAM by either: - Recharging of local groundwater (infiltration/soakaway application). - Controlling and reducing volume release of stormwater into watercourses (or existing sewer systems) by attenuation.• Aerobic purification to improve quality of surface water run-off.• Sustainable, cost effective management of the water environment.
Keytec Geomembranes can supply and install these systems with appropriate impermeable membrane according to the soil conditions and geotextile as a protection or for a soakaway.
AQUACELLPLUSFor Inspectability & Trafficked Sites
AQUACELLCOREFor Trafficked Sites
AQUACELLECOFor Landscaped or Non-Trafficked Sites
by
BBA CERTIFICATE 03/4018
www.keytec.co.uk email: [email protected]
NO YES NO YES
Will the base of tank be more than 4.25m deep?
Will the base of tank need to be installedextra deep (i.e. deeper than 4.1m
in ideal soil conditions)?
NO YES
Will the base of tank be more than 1.5m deep?
NO YES
Will both tank length and width bemore than 12m?
NO YES
Does the site have a high water table?
NO YES
Will the site be subject to traffic loading?
Use:to 4.25m deep
Eco AquaCell Eco*
Core AquaCell Core
Plus AquaCell Plus
Core
OR a combination of:to 1.5m deep andEcoto 4.25m deepCore
Use a combination of:
For any height greater than 2m or for tanks in high water tables please contact Wavin Technical Design on 0844 8565161.
* AquaCell Eco units cannot be directly connected to AquaCell Plus.
Maximum height of tank = 2m (5 Units). Allowable maximum depth to base of units is dependant on soil type, angle of shearing resistance, loading and groundwater level.The above depths are based on a 38° angle of shearing resistance and no groundwater.
to 1.5m deep with* Ecoto 4.25m deep andCoreto 5.08m deepPlus
Use:to 4.1m deepCore
Use a combination of:to 4.1m deep andCoreto 4.78m deepPlus
Use:to 1.5m deep Eco
The following selector will help you to determine which AquaCell system, or combination of systems, is the correct choice for a particular project.
Keytec SUDS can be used as the most efficient capture, transportation, cleansing, infiltration, attenuation and re-use of storm water at source.
15
Keytec GeomembranesPROPERTY UNIT 200 300 TEST METHOD
Thickness mm 1.4 1.8 EN ISO 9864
Area weight g/m² 200 300 EN 9863
Strength MD kN/m 16 25 EN ISO 10319
Strength CD kN/m 16 25 EN ISO 10319
Elongation MD % 45 50 EN ISO 10319
Elongation CD % 45 55 EN ISO 10319
CBR puncture resistance kN 4.2 2.8 EN ISO 12236
Cone drop test mm 13 19 EN ISO 13433
Opening size 090 mm 0.09 0.07 EN ISO 12956
Permeability m.sˉ¹ - l/m²s 0.06/60 0.04/40 EN ISO 11058
Roll Width m 2.5 2.5
Length m 100 100
The values correspond to average results obtained and are indicative. Above mentioned data is informative only.
THERE ARE 3 TYPES OF GEOTEXTILES
• Spun bonded (polyesters, spun glass ) Application, drainage and road construction
• Woven (polypropylene, polyester) Application, ground stability, road construction
• Needle punched (polypropylene) Application, all types of protection to membrane lining
Larger roll sizes and specification available on request.
SPECIALIST SUB-CONTRACT INSTALLATION SERVICES
Keytec Geotextiles can be used for infiltration, separation and liner protection for a multitude of applications including road, railway, slope protection, river bed & bank protection, landfill construction, drainage (SUDS).
Keytec Geotextile
All of the above can be supplied in pre-fabricated form for self installation.
• Installers of adhesive sheet membrane
• Water industry liners and associated works
• Reservoir roof waterproof liners
• Reed bed liners
• Pond & lagoon liners
• Bund liners
• Stainless steel and aluminium components
• Slurry pit liners
• Gas protection
• Manufacturers of gas barriers (Keytec 400 and Keytec Multi)
• Methane, carbon dioxide and radon protection
• Hydrocarbon protection
• Gas ventilation systems and bespoke vents
• Cut-off trench liners
• Stormwater management systems (SUDS)
• Adhesive sheet membrane systems
• Reservoir roofs, walls, basements and underground structures
• Anti-slip membranes
• Waste containment
• Japanese Knotweed containment
www.keytec.co.uk email: [email protected]
DISCLAIMER
The properties and values presented herein are to be considered only typical. No warranty or guarantee expressed or implied is made regarding the performance of the product, since the manner of use and handling is beyond our control.
Nothing contained herein is to be construed as permission or as a recommendation to infringe any patent.
17
VALUE
www.keytec.co.uk email: [email protected]
GeomembranesLINING SOLUTIONS
GeomembranesLINING SOLUTIONS
by
Industry PartnersClient ListSome of the clients that have used the services of Keytec Geomembranes: Keytec are an ISO 9001 Registered Firm, members of the International Accreditation Board
and the Utilities Prequalification Scheme.
Keytec are also proud to be industry partners with all of the following:
Puraflex® is a Registered Trade Name of Industrial Textiles & Plastics Ltd.
CONTRACTORSAcrabuild (Anglia) Anderson Group Appollo Property Services Ashvale CE Balfour Beatty CE BAM Nuttall CE Barnwood Construction Bestcon CE (Eire)Birch BrothersBridgebankCadman ConstructionCarter Lauren ConstructionDawnus ConstructionFrankis SolutionsFred Champion GroundworksFoundation DevelopmentsGaliford Try Group G F Tomlinson Ground Construct Hewitt Sportsturf Houlihan & Co Interserve Group ISG Regions J Breheny ContractorsJones Brothers (Henlan)
DEVELOPERSBarratt Homes GroupBellway HomesHerbert Leach HomesJelson HomesMidas HomesMiller HomesPersimmon Homes GroupRoe DevelopmentsTaylor WimpeyWestern Homes
BUILDERS MERCHANTSKeyline Travis Perkins SwiftecSIGWrekin W T Burdens
K W Bell ContractorsKier GroupKiernan ConstructionLeadbitterLand & Water ServicesLaing O’RourkeLeicestershire CCMcMahon ContractorsMorgan Sindall PLCM V KellyR G CarterO’Brien ContractorsO’Halloran & O’BrienP B DoyleReilly GroundworksRochford ContractorsSevern Trent WaterSouth Midland ConstructionTamdown GroupTarmac National ContractingTrant ConstructionVinci GroupWates Group
Keytec is working for a safer environment...
www.keytec.co.uk email: [email protected] 19