27
How to output continuous sin, square, triangle, pulse or any waveform through a DAQ Using USB 6008/9 & USB 6211 DAQs

Generate Continuous Signals Using 6211

Embed Size (px)

DESCRIPTION

labview

Citation preview

Page 1: Generate Continuous Signals Using 6211

How to output continuous sin, square, triangle, pulse or any

waveform through a DAQ

Using USB 6008/9& USB 6211

DAQs

Page 2: Generate Continuous Signals Using 6211

First: Using USB 6008/9 DAQs

Page 3: Generate Continuous Signals Using 6211

Using USB 6008/9 DAQs

Unfortunately USB 6008/9 Can not generate continues waveforms but it can generate:

• A pulse with pulse width>500 msec through an analog output as shown in the next example

Page 4: Generate Continuous Signals Using 6211

Generating a pulse with pulse widths>500msec using USB-6008 DAQs

through an analog output channel

Set to1 sample on

demand

Pulse through an analog output with pulse width>500 msec

Page 5: Generate Continuous Signals Using 6211

Second: Using USB 6211 DAQs

Page 6: Generate Continuous Signals Using 6211

Using USB 6211 DAQBy USB 6211 DAQ you can generate:

1- Up to two continues (sin, triangle, pulse and square) waveforms through any of the two analog output channels. Using this DAQ you can generate a perfect continuous signal up to 30 kHz.

2- Extra two square waves (or pulses) through the counter output channels with frequency reaches 10 MHz.

Page 7: Generate Continuous Signals Using 6211

Generating a pulse using analog output channel in the USB-6211 DAQ

Set toN samples

Page 8: Generate Continuous Signals Using 6211
Page 9: Generate Continuous Signals Using 6211

Generating any signal (sine, square or triangle) using the USB-6211 Daq

Generating a continuous (sin, triangle or square) waveforms using analog output

channel in the USB-6211 DAQ

You can selectAny signal VI

You can changethe phase too Set to

ContinuousSamples

Page 10: Generate Continuous Signals Using 6211

When frequency Is less than 30kHz

The generated signal is very good in shape

Page 11: Generate Continuous Signals Using 6211

Generating two continuous (sin, triangle or square) waveforms using analog output channel in

the USB-6211 DAQ

Select both analogOutputs at the same

time

Page 12: Generate Continuous Signals Using 6211

Generating two continuous (sin, triangle or square) waveforms using analog output

channel in the USB-6211 DAQ

Page 13: Generate Continuous Signals Using 6211

Generating a pulse or N pulses with up to 50 nsec pulse width using USB-6211 DAQ

through the counter output channel

Put the number of pulses

Page 14: Generate Continuous Signals Using 6211

Generating a pulse or N pulses with up to 50 nsec pulse width using USB-6211 DAQ

through the counter output channel Second Method

Put the number of pulses

Page 15: Generate Continuous Signals Using 6211

Generating a square wave using USB-6211 DAQs through the counter output channel

Page 16: Generate Continuous Signals Using 6211

Generating a square wave using USB-6211 DAQs through the counter output channel

Second Method

Page 17: Generate Continuous Signals Using 6211

Generating the extra continuous square waveforms

• Next example shows how to generate three square waveforms, one using analog output channel and the extra two using counter output channels

Page 18: Generate Continuous Signals Using 6211

Set toContinuous

Samples

Page 19: Generate Continuous Signals Using 6211
Page 20: Generate Continuous Signals Using 6211

Set toContinuous

Samples

Second METOD

Page 21: Generate Continuous Signals Using 6211
Page 22: Generate Continuous Signals Using 6211

Note • You can change the amplitude, phase and

the off set of the signal waveforms generated from the analog output channel.

• The square (or pulse) generate from the counter output channels (2 channels) its amplitude is fixed and between 0 and 5V. And you can not control the phase

Page 23: Generate Continuous Signals Using 6211

Next example shows how to generate three pulse waveforms, one using analog output channel and the extra two using counter

output channels

Page 24: Generate Continuous Signals Using 6211

Set toN samples

Page 25: Generate Continuous Signals Using 6211

Set to 1For 1 pulse

Page 26: Generate Continuous Signals Using 6211

Set toN samples

Second METOD

Page 27: Generate Continuous Signals Using 6211

Set to 1For 1 pulse