18
S S J J J S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S J 12"W X 2"H 12"W X 2"H 12"W X 2"H 4"C TO AV 2108 4"C TO AV 2108 4"C TO IDF 2201B 4"C TO IDF 2201B 1 TYP. 4"C TO IDF 2006 4"C TO IDF 2006 2 4"C TO IDF 2006 4"C TO IDF 2006 2-1 2-2 2-4 2-7 2-7.4 2-9 2-12 2-14 2-15 2-A 2-B 2-C 2-D 2-E 2-F 2-G 2-H 2-J 2-K 2-L 2-M 2-4.5 2-H.7 2-H.5 K E Y P L A N L E G E N D : 0 - C A M P U S / S I T E 1 - ( E ) B A B C O X 2 - C O U R T T O W E R 3 - T U N N E L 4 - ( E ) C O U R T A D M I N 5 - ( E ) B R I D G E N PROJECT CLIENT REGISTRATION LAKE COUNTY 18 N. COUNTY STREET WAUKEGAN, ILLINOIS 847.377.2929 tel 847.984.5889 fax STRUCTURAL AECOM 999 TOWN AND COUNTRY ROAD ORANGE, CA 92868 312.373.7700 tel 312.938.1109 fax www.aecom.com MEP/FP SYSKA HENNESSY GROUP, INC. 330 N. WABASH AVE. CHICAGO, IL. 60611 SUITE 1505 312.588.3561 tel 312.588.3579 fax www.syska.com CODE/LIFE SAFETY ROLF JENSEN & ASSOCIATED, INC. 600 WEST FULTON STREET CHICAGO, IL. 60661 312.879.7200 tel 312.879.7200 fax www.rjainc.com ISSUE/REVISION SHEET NUMBER SHEET TITLE PROJECT NUMBER Last Plotted: Filename: Printed on ___% Post-Consumer Recycled Content Paper ARCH E1 30" x 42" Project Management Initials: Checked: Approved: 1 2 3 4 5 6 A B C D E 6 5 4 3 2 1 CONSULTANTS ARCHITECT AECOM 303 EAST WACKER DRIVE, CHICAGO, IL 60601 312.373.7700 tel 312.938.1109 fax www.aecom.com CIVIL CHRISTOPHER B. BURKE, LTD. 9575 W. HIGGINS ROAD ROSEMONT, IL. 60018 SUITE 600 847.823.0500 tel 847.823.0520 fax LANDSCAPE AECOM 303 EAST WACKER DRIVE, CHICAGO, IL. 60601 SUITE 600 312.373.7792 tel www.aecom.com DATA TELCOM / AUDIO VISUAL AECOM 800 LASALLE AVE MINNEAPOLIS, MN 55402 SUITE 400 612.376.2169 tel www.aecom.com ELECTRONIC SECURITY AECOM 2950 PROFESSIONAL PLACE COLORADO SPRINGS, CO 80904 SUITE 201 719.386.8309 tel 719.386.8339 fax www.aecom.com KEY PLAN SCALE: N.T.S. FOOD SERVICE S1 FOOD SERVICE 231 HOMEWOOD DRIVE BOLINGBROOK, IL 60440 630.783.9232 tel http://s1foodservice.com/ 1A 1C 1B 3 5 4 2 9/22/2015 12:22:53 PM C:\Users\cancioa\Documents\LCCH_TOWER_T12_CENTRAL_cancioa.rvt LAKE COUNTY COURTHOUSE EXPANSION WAUKEGAN, ILLINOIS 60085 301 WASHINGTON STREET LEVEL 2 - TELECOM CABLE TRAY AND PATHWAYS PLAN 2.T212 60288271 N OLEKE 2.T212 REF: 2.T401 SCALE: 1/8" = 1'-0" 1 LEVEL 2 - TELECOM CABLE TRAY RCP GENERAL TELECOM NOTES A. UNLESS OTHERWISE NOTED ALL TELECOM CONDUIT STUBS SHALL BE MINIMUM 1" EMT ROUTED TO ABOVE CEILING WITH INSULATED BUSHINGS. UNLESS OTHERWISE NOTED ALL WALL OUTLET BOXES FOR TELECOM TERMINATIONS SHALL BE 2-GANG, 2-1/8" DEEP BOXES WITH SINGLE-GANG MUD RINGS. B. ALL HORIZONTAL CABLING SHALL BE CATEGORY 6. REFER TO SPECIFICATION FOR FURTHER INFORMATION AND REQUIREMENTS. C. CONTRACTOR TO FIELD VERIFY INSTALLATION CONDITIONS PRIOR TO INSTALLATION. CONTRACTOR SHALL MAKE EVERY EFFORT TO PERFORM INSTALLATION FOLLOWING LATEST GUIDELINES OF TIA-568, -569, AND -607. D. CONTRACTOR TO FOLLOW MANUFACTURER'S RECOMMENDED INSTALLATION METHODS/PRACTICES FOR CAT 6. E. ALL CABLING SHALL BE INSTALLED USING CABLE TRAY IN GENERAL PATHWAYS. F. REFER TO INTERIOR FINISH PLANS AND SPECIFICATION FOR FACEPLATES COLORS. G. ALL CATEGORY 6 CABLES WILL BE TERMINATED, LABELED AND TESTED. REFER TO SPECIFICATION FOR FURTHER INFORMATION AND REQUIREMENTS. H. ALL CEILING DEVICES SHALL BE COORDINATED WITH ARCHITECTURAL AND INTERIORS REFLECTED CEILING PLAN DRAWINGS. I. ALL WALL AND FURNITURE DEVICES SHALL BE COORDINATED WITH ARCHITECTURAL AND INTERIORS DRAWINGS AND ELEVATIONS. J. ALL DUAL COMPARTMENT (NOMINAL AND LOW VOLTAGE) FLOOR BOXES SHALL BE COORDINATED WITH ELECTRICAL DRAWINGS. FLOOR BOXES PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. K. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR RCP ALL DEVICES, EQUIPMENT AND CEILING TYPES. TELECOM KEYNOTE LEGEND NOTE # KEYNOTE TEXT 1 CABLE TRAY SHALL BE A MINIMUM OF 2" HIGH X 12" WIDE. ALL CABLE TRAY SHALL BE A MINIMUM OF 12" ON ALL SIDES FROM OTHER MECHANICAL, PLUMBING, ELECTRICAL AND LIGHTING EQUIPMENT, DEVICES AND PATHWAYS; ETC. SEE SPECIFICATION AND REFER TO CABLE MANUFACTURERS PATHWAYS CABLE FILL FOR ADDITIONAL REQUIREMENTS. 2 PROVIDE (2) 4" CONDUITS WITH 3-CELL MESH INNERDUCT W/PULL STRINGS AND INSULATED BUSHINGS ON EACH END BETWEEN TELECOMMUNICATIONS AND AUDIO VIDEO ROOMS AS SHOWN. CONDUIT SHALL BE A MINIMUM OF 12" ON ALL SIDES FROM OTHER MECHANICAL, PLUMBING, ELECTRICAL AND LIGHTING EQUIPMENT, DEVICES AND PATHWAYS; ETC. SEE SPECIFICATION AND REFER TO CABLE MANUFACTURERS PATHWAYS CABLE FILL FOR ADDITIONAL REQUIREMENTS. I/R DATE DESCRIPTION 2013.12.20 50% CCT GMP PACKAGE 2014.02.12 50% TOWER GMP 2014.03.31 TOWER BID SET 2014.11.03 CONSOLIDATED GMP FINAL 2015.04.21 RFI 185 2015.09.22 ISSUE FOR CONSTRUCTION 2015.10.16 FINAL ISSUED FOR CONSTRUCTION SERVICES OF ILLINOIS, INC. RFI-1029

GENERAL TELECOM NOTES

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GENERAL TELECOM NOTES

S

S

JJ

J

S

S

S

S S

S S S

S

S

S

S

S

S S S S S

SSSS

S

S

S S

S

S S

S

S S

S

S

SS

S S

S S

S S

S

S

S

S

J

12"W X 2"H

12"W

X 2

"H

12"W X 2"H

4"C TO AV2108

4"C TO AV2108

4"C TO IDF2201B

4"C TO IDF2201B

1 TYP.

4"C TO IDF2006

4"C TO IDF2006

2

4"C TO IDF2006

4"C TO IDF2006

2-1 2-2 2-4 2-7 2-7.4 2-9 2-12 2-14 2-15

2-A

2-B

2-C

2-D

2-E

2-F

2-G

2-H

2-J

2-K

2-L

2-M

2-4.5

2-H.7

2-H.5

KEYPLAN LEGEND:0 - CAMPUS/ SITE1 - (E) BABCOX2 - COURT TOWER3 - TUNNEL4 - (E) COURT ADMIN5 - (E) BRIDGE

N

PROJECT

CLIENT

REGISTRATION

LAKE COUNTY18 N. COUNTY STREETWAUKEGAN, ILLINOIS847.377.2929 tel 847.984.5889 fax

STRUCTURALAECOM999 TOWN AND COUNTRY ROADORANGE, CA 92868312.373.7700 tel 312.938.1109 faxwww.aecom.com

MEP/FPSYSKA HENNESSY GROUP, INC.330 N. WABASH AVE.CHICAGO, IL. 60611 SUITE 1505312.588.3561 tel 312.588.3579 faxwww.syska.com

CODE/LIFE SAFETYROLF JENSEN & ASSOCIATED, INC.600 WEST FULTON STREETCHICAGO, IL. 60661312.879.7200 tel 312.879.7200 faxwww.rjainc.com

ISSUE/REVISION

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

Last

Plo

tted:

File

nam

e:

Printed on ___% Post-ConsumerRecycled Content Paper

ARC

H E

1 30

" x 4

2"Pr

ojec

t Man

agem

ent I

nitia

ls:

Che

cked

:Ap

prov

ed:

123456

A

B

C

D

E

6 5 4 3 2 1

CONSULTANTS

ARCHITECT

AECOM303 EAST WACKER DRIVE,CHICAGO, IL 60601312.373.7700 tel 312.938.1109 faxwww.aecom.com

CIVILCHRISTOPHER B. BURKE, LTD.9575 W. HIGGINS ROADROSEMONT, IL. 60018 SUITE 600847.823.0500 tel 847.823.0520 fax

LANDSCAPEAECOM303 EAST WACKER DRIVE,CHICAGO, IL. 60601 SUITE 600312.373.7792 telwww.aecom.com

DATA TELCOM / AUDIO VISUALAECOM800 LASALLE AVEMINNEAPOLIS, MN 55402 SUITE 400612.376.2169 telwww.aecom.com

ELECTRONIC SECURITYAECOM2950 PROFESSIONAL PLACECOLORADO SPRINGS, CO 80904 SUITE 201719.386.8309 tel 719.386.8339 faxwww.aecom.com

KEY PLANSCALE: N.T.S.

FOOD SERVICES1 FOOD SERVICE231 HOMEWOOD DRIVEBOLINGBROOK, IL 60440630.783.9232 telhttp://s1foodservice.com/

1A1C

1B

35

4

2

9/22

/201

5 12

:22:

53 P

MC

:\Use

rs\c

anci

oa\D

ocum

ents

\LC

CH

_TO

WER

_T12

_CEN

TRAL

_can

cioa

.rvt

LAKE COUNTYCOURTHOUSEEXPANSION

WAUKEGAN, ILLINOIS 60085301 WASHINGTON STREET

LEVEL 2 - TELECOM CABLE TRAYAND PATHWAYS PLAN

2.T212

60288271

N OLE

KE

2.T212 REF: 2.T401 SCALE: 1/8" = 1'-0"

1 LEVEL 2 - TELECOM CABLE TRAY RCP

GENERAL TELECOM NOTESA. UNLESS OTHERWISE NOTED ALL TELECOM CONDUIT STUBS SHALL BE MINIMUM 1"

EMT ROUTED TO ABOVE CEILING WITH INSULATED BUSHINGS. UNLESS OTHERWISENOTED ALL WALL OUTLET BOXES FOR TELECOM TERMINATIONS SHALL BE 2-GANG,2-1/8" DEEP BOXES WITH SINGLE-GANG MUD RINGS.

B. ALL HORIZONTAL CABLING SHALL BE CATEGORY 6. REFER TO SPECIFICATION FORFURTHER INFORMATION AND REQUIREMENTS.

C. CONTRACTOR TO FIELD VERIFY INSTALLATION CONDITIONS PRIOR TO INSTALLATION.CONTRACTOR SHALL MAKE EVERY EFFORT TO PERFORM INSTALLATION FOLLOWINGLATEST GUIDELINES OF TIA-568, -569, AND -607.

D. CONTRACTOR TO FOLLOW MANUFACTURER'S RECOMMENDED INSTALLATIONMETHODS/PRACTICES FOR CAT 6.

E. ALL CABLING SHALL BE INSTALLED USING CABLE TRAY IN GENERAL PATHWAYS.F. REFER TO INTERIOR FINISH PLANS AND SPECIFICATION FOR FACEPLATES COLORS.G. ALL CATEGORY 6 CABLES WILL BE TERMINATED, LABELED AND TESTED. REFER TO

SPECIFICATION FOR FURTHER INFORMATION AND REQUIREMENTS.H. ALL CEILING DEVICES SHALL BE COORDINATED WITH ARCHITECTURAL AND

INTERIORS REFLECTED CEILING PLAN DRAWINGS.I. ALL WALL AND FURNITURE DEVICES SHALL BE COORDINATED WITH ARCHITECTURAL

AND INTERIORS DRAWINGS AND ELEVATIONS.J. ALL DUAL COMPARTMENT (NOMINAL AND LOW VOLTAGE) FLOOR BOXES SHALL BE

COORDINATED WITH ELECTRICAL DRAWINGS. FLOOR BOXES PROVIDED ANDINSTALLED BY ELECTRICAL CONTRACTOR.

K. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR RCP ALL DEVICES,EQUIPMENT AND CEILING TYPES.

TELECOM KEYNOTE LEGENDNOTE

# KEYNOTE TEXT1 CABLE TRAY SHALL BE A MINIMUM OF 2" HIGH X 12" WIDE. ALL CABLE TRAY SHALL BE A MINIMUM OF 12"

ON ALL SIDES FROM OTHER MECHANICAL, PLUMBING, ELECTRICAL AND LIGHTING EQUIPMENT, DEVICESAND PATHWAYS; ETC. SEE SPECIFICATION AND REFER TO CABLE MANUFACTURERS PATHWAYS CABLEFILL FOR ADDITIONAL REQUIREMENTS.

2 PROVIDE (2) 4" CONDUITS WITH 3-CELL MESH INNERDUCT W/PULL STRINGS AND INSULATED BUSHINGS ONEACH END BETWEEN TELECOMMUNICATIONS AND AUDIO VIDEO ROOMS AS SHOWN. CONDUIT SHALL BE AMINIMUM OF 12" ON ALL SIDES FROM OTHER MECHANICAL, PLUMBING, ELECTRICAL AND LIGHTINGEQUIPMENT, DEVICES AND PATHWAYS; ETC. SEE SPECIFICATION AND REFER TO CABLE MANUFACTURERSPATHWAYS CABLE FILL FOR ADDITIONAL REQUIREMENTS.

I/R DATE DESCRIPTION

2013.12.20 50% CCT GMP PACKAGE2014.02.12 50% TOWER GMP2014.03.31 TOWER BID SET2014.11.03 CONSOLIDATED GMP FINAL2015.04.21 RFI 1852015.09.22 ISSUE FOR CONSTRUCTION2015.10.16 FINAL ISSUED FOR CONSTRUCTION

SERVICES OF ILLINOIS, INC.

RFI-1029

Page 2: GENERAL TELECOM NOTES

J

S

S

S

S

S

S

S

S

S

SSSSSS S S S

SS S

S SSSSS

S

S S

S

J

J

J

J

S S

S S

S

S

S S

S S

S S

J

J

S

S S

S S

S S

S

J

J J

J

J

J

12"W X 2"H

12"W

X 2

"H

12"W

X 2

"H

12"W

X 2

"H

1 TYP.

2-1 2-2 2-4 2-7 2-7.4 2-9 2-12 2-14 2-15

2-A

2-B

2-C

2-D

2-E

2-F

2-G

2-H

2-J

2-K

2-L

2-M

2-4.5

2-H.7

2-H.512"W X 2"H

1

2

KEYPLAN LEGEND:0 - CAMPUS/ SITE1 - (E) BABCOX2 - COURT TOWER3 - TUNNEL4 - (E) COURT ADMIN5 - (E) BRIDGE

N

PROJECT

CLIENT

REGISTRATION

LAKE COUNTY18 N. COUNTY STREETWAUKEGAN, ILLINOIS847.377.2929 tel 847.984.5889 fax

STRUCTURALAECOM999 TOWN AND COUNTRY ROADORANGE, CA 92868312.373.7700 tel 312.938.1109 faxwww.aecom.com

MEP/FPSYSKA HENNESSY GROUP, INC.330 N. WABASH AVE.CHICAGO, IL. 60611 SUITE 1505312.588.3561 tel 312.588.3579 faxwww.syska.com

CODE/LIFE SAFETYROLF JENSEN & ASSOCIATED, INC.600 WEST FULTON STREETCHICAGO, IL. 60661312.879.7200 tel 312.879.7200 faxwww.rjainc.com

ISSUE/REVISION

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

Last

Plo

tted:

File

nam

e:

Printed on ___% Post-ConsumerRecycled Content Paper

ARC

H E

1 30

" x 4

2"Pr

ojec

t Man

agem

ent I

nitia

ls:

Che

cked

:Ap

prov

ed:

123456

A

B

C

D

E

6 5 4 3 2 1

CONSULTANTS

ARCHITECT

AECOM303 EAST WACKER DRIVE,CHICAGO, IL 60601312.373.7700 tel 312.938.1109 faxwww.aecom.com

CIVILCHRISTOPHER B. BURKE, LTD.9575 W. HIGGINS ROADROSEMONT, IL. 60018 SUITE 600847.823.0500 tel 847.823.0520 fax

LANDSCAPEAECOM303 EAST WACKER DRIVE,CHICAGO, IL. 60601 SUITE 600312.373.7792 telwww.aecom.com

DATA TELCOM / AUDIO VISUALAECOM800 LASALLE AVEMINNEAPOLIS, MN 55402 SUITE 400612.376.2169 telwww.aecom.com

ELECTRONIC SECURITYAECOM2950 PROFESSIONAL PLACECOLORADO SPRINGS, CO 80904 SUITE 201719.386.8309 tel 719.386.8339 faxwww.aecom.com

KEY PLANSCALE: N.T.S.

FOOD SERVICES1 FOOD SERVICE231 HOMEWOOD DRIVEBOLINGBROOK, IL 60440630.783.9232 telhttp://s1foodservice.com/

1A1C

1B

35

4

2

9/22

/201

5 1:

40:1

5 PM

C:\U

sers

\can

cioa

\Doc

umen

ts\L

CC

H_T

OW

ER_T

12_C

ENTR

AL_c

anci

oa.rv

t

LAKE COUNTYCOURTHOUSEEXPANSION

WAUKEGAN, ILLINOIS 60085301 WASHINGTON STREET

LEVEL 5 THRU 7 - TELECOMCABLE TRAY AND PATHWAYSPLAN

2.T214

60288271

N OLE

KE

2.T214 REF: 2.T402 SCALE: 1/8" = 1'-0"

1 LEVEL 5 THRU 8 - TELECOM CABLE TRAY RCPCABLE TRAY AND LADDER RACKS SHOWN ARE TYPICAL FOR FLOORS 4 THRU 8.

GENERAL TELECOM NOTESA. UNLESS OTHERWISE NOTED ALL TELECOM CONDUIT STUBS SHALL BE MINIMUM 1"

EMT ROUTED TO ABOVE CEILING WITH INSULATED BUSHINGS. UNLESS OTHERWISENOTED ALL WALL OUTLET BOXES FOR TELECOM TERMINATIONS SHALL BE 2-GANG,2-1/8" DEEP BOXES WITH SINGLE-GANG MUD RINGS.

B. ALL HORIZONTAL CABLING SHALL BE CATEGORY 6. REFER TO SPECIFICATION FORFURTHER INFORMATION AND REQUIREMENTS.

C. CONTRACTOR TO FIELD VERIFY INSTALLATION CONDITIONS PRIOR TO INSTALLATION.CONTRACTOR SHALL MAKE EVERY EFFORT TO PERFORM INSTALLATION FOLLOWINGLATEST GUIDELINES OF TIA-568, -569, AND -607.

D. CONTRACTOR TO FOLLOW MANUFACTURER'S RECOMMENDED INSTALLATIONMETHODS/PRACTICES FOR CAT 6.

E. ALL CABLING SHALL BE INSTALLED USING CABLE TRAY IN GENERAL PATHWAYS.F. REFER TO INTERIOR FINISH PLANS AND SPECIFICATION FOR FACEPLATES COLORS.G. ALL CATEGORY 6 CABLES WILL BE TERMINATED, LABELED AND TESTED. REFER TO

SPECIFICATION FOR FURTHER INFORMATION AND REQUIREMENTS.H. ALL CEILING DEVICES SHALL BE COORDINATED WITH ARCHITECTURAL AND

INTERIORS REFLECTED CEILING PLAN DRAWINGS.I. ALL WALL AND FURNITURE DEVICES SHALL BE COORDINATED WITH ARCHITECTURAL

AND INTERIORS DRAWINGS AND ELEVATIONS.J. ALL DUAL COMPARTMENT (NOMINAL AND LOW VOLTAGE) FLOOR BOXES SHALL BE

COORDINATED WITH ELECTRICAL DRAWINGS. FLOOR BOXES PROVIDED ANDINSTALLED BY ELECTRICAL CONTRACTOR.

K. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR RCP ALL DEVICES,EQUIPMENT AND CEILING TYPES.

TELECOM KEYNOTE LEGENDNOTE

# KEYNOTE TEXT1 CABLE TRAY SHALL BE A MINIMUM OF 2" HIGH X 12" WIDE. ALL CABLE TRAY SHALL BE A MINIMUM OF 12"

ON ALL SIDES FROM OTHER MECHANICAL, PLUMBING, ELECTRICAL AND LIGHTING EQUIPMENT, DEVICESAND PATHWAYS; ETC. SEE SPECIFICATION AND REFER TO CABLE MANUFACTURERS PATHWAYS CABLEFILL FOR ADDITIONAL REQUIREMENTS.

I/R DATE DESCRIPTION

2013.12.20 50% CCT GMP PACKAGE2014.02.12 50% TOWER GMP2014.03.31 TOWER BID SET2014.11.03 CONSOLIDATED GMP FINAL2015.04.21 RFI 1852015.09.22 ISSUE FOR CONSTRUCTION2015.10.16 FINAL ISSUED FOR CONSTRUCTION

SERVICES OF ILLINOIS, INC.

RFI-1023

RFI-1150

Page 3: GENERAL TELECOM NOTES

C

S

S S

S

S SS

S SS

S SS SS

S S

SS

S

S S

SS

S

S

S

S

J

J

J

J

J

C

SJ

S

SS

SJ

S

SS

S

S

S

S

C

12"W X 2"H

12"W

X 2

"H

12"W

X 2

"H

12"W X 2"H

1 4"C TO AV8402

4"C TO AV8402

4"C TO IDF8312

4"C TO IDF8312

2

2

TYP.

2-1 2-2 2-4 2-7 2-7.4 2-9 2-12 2-14 2-15

2-A

2-B

2-C

2-D

2-E

2-F

2-G

2-H

2-J

2-K

2-L

2-M

2-4.5

2-H.7

2-H.5 12"W X 2"H

KEYPLAN LEGEND:0 - CAMPUS/ SITE1 - (E) BABCOX2 - COURT TOWER3 - TUNNEL4 - (E) COURT ADMIN5 - (E) BRIDGE

N

PROJECT

CLIENT

REGISTRATION

LAKE COUNTY18 N. COUNTY STREETWAUKEGAN, ILLINOIS847.377.2929 tel 847.984.5889 fax

STRUCTURALAECOM999 TOWN AND COUNTRY ROADORANGE, CA 92868312.373.7700 tel 312.938.1109 faxwww.aecom.com

MEP/FPSYSKA HENNESSY GROUP, INC.330 N. WABASH AVE.CHICAGO, IL. 60611 SUITE 1505312.588.3561 tel 312.588.3579 faxwww.syska.com

CODE/LIFE SAFETYROLF JENSEN & ASSOCIATED, INC.600 WEST FULTON STREETCHICAGO, IL. 60661312.879.7200 tel 312.879.7200 faxwww.rjainc.com

ISSUE/REVISION

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

Last

Plo

tted:

File

nam

e:

Printed on ___% Post-ConsumerRecycled Content Paper

ARC

H E

1 30

" x 4

2"Pr

ojec

t Man

agem

ent I

nitia

ls:

Che

cked

:Ap

prov

ed:

123456

A

B

C

D

E

6 5 4 3 2 1

CONSULTANTS

ARCHITECT

AECOM303 EAST WACKER DRIVE,CHICAGO, IL 60601312.373.7700 tel 312.938.1109 faxwww.aecom.com

CIVILCHRISTOPHER B. BURKE, LTD.9575 W. HIGGINS ROADROSEMONT, IL. 60018 SUITE 600847.823.0500 tel 847.823.0520 fax

LANDSCAPEAECOM303 EAST WACKER DRIVE,CHICAGO, IL. 60601 SUITE 600312.373.7792 telwww.aecom.com

DATA TELCOM / AUDIO VISUALAECOM800 LASALLE AVEMINNEAPOLIS, MN 55402 SUITE 400612.376.2169 telwww.aecom.com

ELECTRONIC SECURITYAECOM2950 PROFESSIONAL PLACECOLORADO SPRINGS, CO 80904 SUITE 201719.386.8309 tel 719.386.8339 faxwww.aecom.com

KEY PLANSCALE: N.T.S.

FOOD SERVICES1 FOOD SERVICE231 HOMEWOOD DRIVEBOLINGBROOK, IL 60440630.783.9232 telhttp://s1foodservice.com/

1A1C

1B

35

4

2

9/22

/201

5 12

:23:

59 P

MC

:\Use

rs\c

anci

oa\D

ocum

ents

\LC

CH

_TO

WER

_T12

_CEN

TRAL

_can

cioa

.rvt

LAKE COUNTYCOURTHOUSEEXPANSION

WAUKEGAN, ILLINOIS 60085301 WASHINGTON STREET

LEVEL 8 - TELECOM CABLE TRAYAND PATHWAYS PLAN

2.T218

60288271

N OLE

KE

2.T218 REF: 2.T402 SCALE: 1/8" = 1'-0"

1 LEVEL 9 - TELECOM CABLE TRAY RCP

GENERAL TELECOM NOTESA. UNLESS OTHERWISE NOTED ALL TELECOM CONDUIT STUBS SHALL BE MINIMUM 1"

EMT ROUTED TO ABOVE CEILING WITH INSULATED BUSHINGS. UNLESS OTHERWISENOTED ALL WALL OUTLET BOXES FOR TELECOM TERMINATIONS SHALL BE 2-GANG,2-1/8" DEEP BOXES WITH SINGLE-GANG MUD RINGS.

B. ALL HORIZONTAL CABLING SHALL BE CATEGORY 6. REFER TO SPECIFICATION FORFURTHER INFORMATION AND REQUIREMENTS.

C. CONTRACTOR TO FIELD VERIFY INSTALLATION CONDITIONS PRIOR TO INSTALLATION.CONTRACTOR SHALL MAKE EVERY EFFORT TO PERFORM INSTALLATION FOLLOWINGLATEST GUIDELINES OF TIA-568, -569, AND -607.

D. CONTRACTOR TO FOLLOW MANUFACTURER'S RECOMMENDED INSTALLATIONMETHODS/PRACTICES FOR CAT 6.

E. ALL CABLING SHALL BE INSTALLED USING CABLE TRAY IN GENERAL PATHWAYS.F. REFER TO INTERIOR FINISH PLANS AND SPECIFICATION FOR FACEPLATES COLORS.G. ALL CATEGORY 6 CABLES WILL BE TERMINATED, LABELED AND TESTED. REFER TO

SPECIFICATION FOR FURTHER INFORMATION AND REQUIREMENTS.H. ALL CEILING DEVICES SHALL BE COORDINATED WITH ARCHITECTURAL AND

INTERIORS REFLECTED CEILING PLAN DRAWINGS.I. ALL WALL AND FURNITURE DEVICES SHALL BE COORDINATED WITH ARCHITECTURAL

AND INTERIORS DRAWINGS AND ELEVATIONS.J. ALL DUAL COMPARTMENT (NOMINAL AND LOW VOLTAGE) FLOOR BOXES SHALL BE

COORDINATED WITH ELECTRICAL DRAWINGS. FLOOR BOXES PROVIDED ANDINSTALLED BY ELECTRICAL CONTRACTOR.

K. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR RCP ALL DEVICES,EQUIPMENT AND CEILING TYPES.

TELECOM KEYNOTE LEGENDNOTE

# KEYNOTE TEXT1 CABLE TRAY SHALL BE A MINIMUM OF 2" HIGH X 12" WIDE. ALL CABLE TRAY SHALL BE A MINIMUM OF 12"

ON ALL SIDES FROM OTHER MECHANICAL, PLUMBING, ELECTRICAL AND LIGHTING EQUIPMENT, DEVICESAND PATHWAYS; ETC. SEE SPECIFICATION AND REFER TO CABLE MANUFACTURERS PATHWAYS CABLEFILL FOR ADDITIONAL REQUIREMENTS.

2 PROVIDE (2) 4" CONDUITS WITH 3-CELL MESH INNERDUCT W/PULL STRINGS AND INSULATED BUSHINGS ONEACH END BETWEEN TELECOMMUNICATIONS AND AUDIO VIDEO ROOMS AS SHOWN. CONDUIT SHALL BE AMINIMUM OF 12" ON ALL SIDES FROM OTHER MECHANICAL, PLUMBING, ELECTRICAL AND LIGHTINGEQUIPMENT, DEVICES AND PATHWAYS; ETC. SEE SPECIFICATION AND REFER TO CABLE MANUFACTURERSPATHWAYS CABLE FILL FOR ADDITIONAL REQUIREMENTS.

I/R DATE DESCRIPTION

2013.12.20 50% CCT GMP PACKAGE2014.02.12 50% TOWER GMP2014.03.31 TOWER BID SET2014.11.03 CONSOLIDATED GMP FINAL2015.04.21 RFI 1852015.09.22 ISSUE FOR CONSTRUCTION2015.10.16 FINAL ISSUED FOR CONSTRUCTION

SERVICES OF ILLINOIS, INC.

RFI-1150

Page 4: GENERAL TELECOM NOTES

CCT-B1-2CCT-B1-3

CCT-B1-4CCT-B1-5 CCT-B1-6

CCT-B1-7CCT-B1-8

CCT-B1-9CCT-B1-10

CCT-B1-11CCT-B1-12

CCT-B1-13CCT-B1-14

CCT-B1-15

CCT-B1-1

HB1.1HB1.2A/V A/V

2.T4031

T

CRAC CRAC

3 3

UPS

4

5

BAS

6

3-F

3-13

2-152-143-14

2-12 2-142-15

2-F

LEVEL 2 - D/T FLOOR PLAN675' - 6"

LEVEL 1 - D/T FLOOR PLAN657' - 2"

9' -

3"

16' -

8 2

7/32

"

1

2

ROOF PLAN (663'-0")663' - 8"

TOW (668'-4")668' - 9"

TO PARAPET669' - 11 3/4"

3-13

2-14

LEVEL 2 - D/T FLOOR PLAN675' - 6"

LEVEL 1 - D/T FLOOR PLAN657' - 2"

2-4

AV AV AV AV AV AV

7' -

10"

LEVEL 1 (657'-0")656' - 5 3/4"

ROOF PLAN (663'-0")663' - 8"

TOW (668'-4")668' - 9"

TO PARAPET669' - 11 3/4"

LEVEL 2 - D/T FLOOR PLAN675' - 6"

LEVEL 1 - D/T FLOOR PLAN657' - 2"

AV AV AV

AV AV AV

4' -

3"5'

- 7"

LEVEL 1 (657'-0")656' - 5 3/4"

ROOF PLAN (663'-0")663' - 8"

TOW (668'-4")668' - 9"

TO PARAPET669' - 11 3/4"

CCT-B1-1

CCT-B1-2

CCT-B1-3

CCT-B1-4

CCT-B1-5

CCT-B1-6

CCT-B1-7

CCT-B1-8

CCT-B1-9

CCT-B1-10

CCT-B1-11 CCT-B1-13CCT-B1-14

CCT-B1-15

CCT-B1-12

HB1.2 HB1.1

MDF

B1-006

7

8

2-12 2-142-15

2-F

PROJECT

CLIENT

REGISTRATION

LAKE COUNTY18 N. COUNTY STREETWAUKEGAN, ILLINOIS847.377.2929 tel 847.984.5889 fax

STRUCTURALAECOM999 TOWN AND COUNTRY ROADORANGE, CA 92868312.373.7700 tel 312.938.1109 faxwww.aecom.com

MEP/FPSYSKA HENNESSY GROUP, INC.330 N. WABASH AVE.CHICAGO, IL. 60611 SUITE 1505312.588.3561 tel 312.588.3579 faxwww.syska.com

CODE/LIFE SAFETYROLF JENSEN & ASSOCIATED, INC.600 WEST FULTON STREETCHICAGO, IL. 60661312.879.7200 tel 312.879.7200 faxwww.rjainc.com

ISSUE/REVISION

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

Last

Plo

tted:

File

nam

e:

Printed on ___% Post-ConsumerRecycled Content Paper

ARC

H E

1 30

" x 4

2"Pr

ojec

t Man

agem

ent I

nitia

ls:

Che

cked

:Ap

prov

ed:

123456

A

B

C

D

E

6 5 4 3 2 1

CONSULTANTS

ARCHITECT

AECOM303 EAST WACKER DRIVE,CHICAGO, IL 60601312.373.7700 tel 312.938.1109 faxwww.aecom.com

CIVILCHRISTOPHER B. BURKE, LTD.9575 W. HIGGINS ROADROSEMONT, IL. 60018 SUITE 600847.823.0500 tel 847.823.0520 fax

LANDSCAPEAECOM303 EAST WACKER DRIVE,CHICAGO, IL. 60601 SUITE 600312.373.7792 telwww.aecom.com

DATA TELCOM / AUDIO VISUALAECOM800 LASALLE AVEMINNEAPOLIS, MN 55402 SUITE 400612.376.2169 telwww.aecom.com

ELECTRONIC SECURITYAECOM2950 PROFESSIONAL PLACECOLORADO SPRINGS, CO 80904 SUITE 201719.386.8309 tel 719.386.8339 faxwww.aecom.com

FOOD SERVICES1 FOOD SERVICE231 HOMEWOOD DRIVEBOLINGBROOK, IL 60440630.783.9232 telhttp://s1foodservice.com/

9/22

/201

5 12

:24:

52 P

MC

:\Use

rs\c

anci

oa\D

ocum

ents

\LC

CH

_TO

WER

_T12

_CEN

TRAL

_can

cioa

.rvt

LAKE COUNTYCOURTHOUSEEXPANSION

WAUKEGAN, ILLINOIS 60085301 WASHINGTON STREET

ENLARGED TELECOM PLANS ANDSECTIONS

2.T401

60288271

N OLE

KE

2.T401 REF: 2.T1B1 SCALE: 1/4" = 1'-0"

1 MDF CCT-B-1 - RM B1-013 - TELECOM ENLARGED PLAN

0 4' 8' 12'2'1'SCALE: 1/4" = 1'-0"

SCALE: 1/2" = 1'-0"2.T401 REF: 2.T402

5

MDF/IDF PARTIAL CONDUITRISER SECTION (TYPICAL ALLFLOORS)

TELECOM KEYNOTE LEGENDNOTE

# KEYNOTE TEXT1 REFER TO SPECIFICATION SECTIONS 270528-PATHWAYS FOR COMMUNICATION SYSTEMS,

271500-COMMUNICATIONS HORIZONTAL CABLING SYSTEMS 271513-COPPER HORIZONTAL CABLING SYSTEMSFOR ADDITIONAL REQUIREMENTS. RISER CONDUITS OR PATHWAY SYSTEM SHALL PENETRATE THE ABOVEFLOOR 4" ABOVE AND 4"BELOW AND MAINTAIN ALL FLOOR FIRE RATINGS. WHERE CONDUITS ARE USEDSHALL BE PROVIDED WITH INSULATED BUSHINGS ON EACH END AND FILLED WITH APPROVED RESTORABLEFIRE STOP MATERIAL.

2 REFER TO SPECIFICATION SECTIONS 270528-PATHWAYS FOR COMMUNICATION SYSTEMS,271500-COMMUNICATIONS HORIZONTAL CABLING SYSTEMS 271513-COPPER HORIZONTAL CABLING SYSTEMSFOR ADDITIONAL REQUIREMENTS. SEE SHEET 2.T408 FOR IDF/MDF HORIZONTAL LADDER RACK LOCATIONS.WHERE CABLING TRANSITIONS FROM VERTICAL LADDER RACK TO HORIZONTAL LADDER RACK SHALLMAINTAIN ALL EIA/TIA MINIMUM BEND RADIUS. CABLES SHALL BE SECURELY FASTENED TO HORIZONTALLADDER RACK USING VELCRO STRAPS AND ALL CABLES SHALL BE BUNDLED WITH LIKE SYSTEMS.COORDINATE WITH AV SHEETS [TA SERIES] FOR AV HORIZONTAL AND BACKBONE CABLING REQUIREMENTS,AV CABLING SHALL BE BUNDLED SEPARATELY FROM TELECOMMUNICATIONS CABLING.

3 PROVIDE 1 DATA DROP FOR CRAC UNIT BACNET/IP CONTROLLER PROVIDED BY DIVISION 23. COORDINATEWITH DIVISION 23 FOR EXACT LOCATION AND REQUIREMENTS.

4 PROVIDE 1 DATA DROP FOR UPS BACNET/IP CONTROLLER PROVIDED BY DIVISION 26/28. COORDINATE WITHDIVISION 26/28 FOR EXACT LOCATION AND REQUIREMENTS.

5 TMGB GROUND BAR AT THIS LOCATION PROVIDED BY DIVISION 26. COORDINATE WITH DIVISION 26 FOREXACT LOCATION.

6 PROVIDE 2 DATA DROPS FOR ELECTRICAL SURGE/TRANSFORMER MONITORING BACNET/IP CONTROLLERPROVIDED BY DIVISION 25. COORDINATE WITH DIVISION 25 FOR EXACT LOCATION AND REQUIREMENTS.

7 CABLE TRAY SHALL BE A MINIMUM OF 2" HIGH X 12" WIDE. ALL CABLE TRAY SHALL BE A MINIMUM OF 12" ONALL SIDES FROM OTHER MECHANICAL, PLUMBING, ELECTRICAL AND LIGHTING EQUIPMENT, DEVICES ANDPATHWAYS; ETC. SEE SPECIFICATION AND REFER TO CABLE MANUFACTURERS PATHWAYS CABLE FILL FORADDITIONAL REQUIREMENTS.

8 DATA AND A/V CONDUIT RISER LOCATIONS SHOWN FOR REFERENCE ONLY, REFER TO SHEET 2.T403 FORFURTHER INFORMATION.

GENERAL TELECOM NOTESA. UNLESS OTHERWISE NOTED ALL TELECOM CONDUIT STUBS SHALL BE MINIMUM 1"

EMT ROUTED TO ABOVE CEILING WITH INSULATED BUSHINGS. UNLESS OTHERWISENOTED ALL WALL OUTLET BOXES FOR TELECOM TERMINATIONS SHALL BE 2-GANG,2-1/8" DEEP BOXES WITH SINGLE-GANG MUD RINGS.

B. ALL HORIZONTAL CABLING SHALL BE CATEGORY 6. REFER TO SPECIFICATION FORFURTHER INFORMATION AND REQUIREMENTS.

C. CONTRACTOR TO FIELD VERIFY INSTALLATION CONDITIONS PRIOR TO INSTALLATION.CONTRACTOR SHALL MAKE EVERY EFFORT TO PERFORM INSTALLATION FOLLOWINGLATEST GUIDELINES OF TIA-568, -569, AND -607.

D. CONTRACTOR TO FOLLOW MANUFACTURER'S RECOMMENDED INSTALLATIONMETHODS/PRACTICES FOR CAT 6.

E. ALL CABLING SHALL BE INSTALLED USING CABLE TRAY IN GENERAL PATHWAYS.F. REFER TO INTERIOR FINISH PLANS AND SPECIFICATION FOR FACEPLATES COLORS.G. ALL CATEGORY 6 CABLES WILL BE TERMINATED, LABELED AND TESTED. REFER TO

SPECIFICATION FOR FURTHER INFORMATION AND REQUIREMENTS.H. ALL CEILING DEVICES SHALL BE COORDINATED WITH ARCHITECTURAL AND

INTERIORS REFLECTED CEILING PLAN DRAWINGS.I. ALL WALL AND FURNITURE DEVICES SHALL BE COORDINATED WITH ARCHITECTURAL

AND INTERIORS DRAWINGS AND ELEVATIONS.J. ALL DUAL COMPARTMENT (NOMINAL AND LOW VOLTAGE) FLOOR BOXES SHALL BE

COORDINATED WITH ELECTRICAL DRAWINGS. FLOOR BOXES PROVIDED ANDINSTALLED BY ELECTRICAL CONTRACTOR.

K. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR RCP ALL DEVICES,EQUIPMENT AND CEILING TYPES.

SCALE: 1/4" = 1'-0"2.T401 REF: 2.T101

3SOUTH MAIN ENTRY DISPLAYTELECOM WALL ELEVATION

SCALE: 1/4" = 1'-0"2.T401 REF: 2.T1B1

4WEST MAIN ENTRY DISPLAYTELECOM ELEVATION

2.T401 REF: 2.T2B1 SCALE: 1/4" = 1'-0"

2 MDF CCT- B1 - RM B1-006 - ENLARGED TELECOM RCP

I/R DATE DESCRIPTION

2013.12.20 50% CCT GMP PACKAGE2014.02.12 50% TOWER GMP2014.03.31 TOWER BID SET2014.11.03 CONSOLIDATED GMP FINAL2015.09.22 ISSUE FOR CONSTRUCTION2015.10.16 FINAL ISSUED FOR CONSTRUCTION

SERVICES OF ILLINOIS, INC.

dnash
Highlight
dnash
Highlight
dnash
Highlight
dnash
Highlight
dnash
Highlight
dnash
Highlight
dnash
Highlight
Page 5: GENERAL TELECOM NOTES

IDF

1202

52.T401

FLOOR DISTRIBUTIONCABLE TRAY

4"C TO AV1314

4"C TO AV1314

2

1

1

4

2-14 2-15

18"W

X 2

"H

18"W X 2"H

18"W

X 2

"H

12"W X 2"H

18"W X 2"H

LEVEL 8 - D/T REFLECTED CEILING PLAN781' - 6"

LEVEL 7 - D/T REFLECTED CEILING PLAN764' - 0"

LEVEL 6 - D/T REFLECTED CEILING PLAN746' - 6"

LEVEL 5 - D/T REFLECTED CEILING PLAN729' - 0"

LEVEL 4 - D/T REFLECTED CEILING PLAN711' - 6"

LEVEL 3 - D/T REFLECTED CEILING PLAN694' - 0"

LEVEL 2 - D/T FLOOR PLAN675' - 6"

LEVEL 1 - D/T FLOOR PLAN657' - 2"

CCT-1-2 CCT-1-1

CCT-2-3CCT-2-2

CCT-2-1

CCT-4-3CCT-4-2

CCT-4-1

CCT-6-3CCT-6-2

CCT-6-1

CCT-7-3CCT-7-2

CCT-7-1

CCT-8-2CCT-8-1

CCT-5-1

HORIZONTAL CABLE TRAYFLOOR DISTRIBUTION

HORIZONTAL CABLE TRAYIDF/MDF DISTRIBUTION

HORIZONTAL CABLE TRAYIDF/MDF DISTRIBUTION

HORIZONTAL CABLE TRAYFLOOR DISTRIBUTION TYP.FLOORS 4 THRU 7.

HORIZONTAL CABLE TRAYIDF/MDF DISTRIBUTION TYP.FLOORS 4 THRU 7.

HORIZONTAL CABLETRAY FLOORDISTRIBUTION

HORIZONTAL CABLETRAY IDF/MDFDISTRIBUTION

9' -

0"14' -

0"

9' -

1"14' -

0"

9' -

1"14' -

0"

9' -

1"14' -

0"

HORIZONTAL CABLE TRAYFLOOR DISTRIBUTION.

LEVEL 09 - ROOF799' - 0"

LEVEL 1 (657'-0")656' - 5 3/4"

ROOF PLAN (663'-0")663' - 8"

TOW (668'-4")668' - 9"

3-F

TO PARAPET669' - 11 3/4"

LEVEL 2 @ BRIDGE676' - 7"

BRIDGE LEVEL HIGH SPAN678' - 10"

T.O. ELEVATOR PARAPET695' - 4"

3-G

2-F 2-G

CCT-8-3

CCT-5-2CCT-5-3

IDF

2201B

4"C

TO

IDF

2006

4"C

TO

IDF

2006

2

2-7

2-F

12"W X 2"H

12"W X 2"H

12"W

X 2

"H

1

2

4"C TO AV2108

4"C TO AV2108

4"C TO IDF2201B

4"C TO IDF2201B

1

FLOOR DISTRIBUTIONCABLE TRAY

4

2-14 2-15

2-F

18"W X 2"H

18"W

X 2

"H

18"W X 2"H

18"W

X 2

"H

1

1 FLOOR DISTRIBUTIONCABLE TRAY

4

2-12 2-14

2-F

12"W X 2"H

12"W X 2"H

18"W

X 2

"H

18"W

X 2

"H

18"W X 2"H

18"W X 2"H

1

4"C TO AV8402

4"C TO AV8402

2

1FLOOR DISTRIBUTIONCABLE TRAY

3

2-14 2-15

2-F

18"W X 2"H

18"W

X 2

"H

18"W

X 2

"H

12"W X 2"H

18"W X 2"H

AV EQUIP

2108

2-J

2-H.7

2-H.5

18"W

X 2

"H

18"W X 2"H

12"W

X 2

"H

2-10

PROJECT

CLIENT

REGISTRATION

LAKE COUNTY18 N. COUNTY STREETWAUKEGAN, ILLINOIS847.377.2929 tel 847.984.5889 fax

STRUCTURALAECOM999 TOWN AND COUNTRY ROADORANGE, CA 92868312.373.7700 tel 312.938.1109 faxwww.aecom.com

MEP/FPSYSKA HENNESSY GROUP, INC.330 N. WABASH AVE.CHICAGO, IL. 60611 SUITE 1505312.588.3561 tel 312.588.3579 faxwww.syska.com

CODE/LIFE SAFETYROLF JENSEN & ASSOCIATED, INC.600 WEST FULTON STREETCHICAGO, IL. 60661312.879.7200 tel 312.879.7200 faxwww.rjainc.com

ISSUE/REVISION

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

Last

Plo

tted:

File

nam

e:

Printed on ___% Post-ConsumerRecycled Content Paper

ARC

H E

1 30

" x 4

2"Pr

ojec

t Man

agem

ent I

nitia

ls:

Che

cked

:Ap

prov

ed:

123456

A

B

C

D

E

6 5 4 3 2 1

CONSULTANTS

ARCHITECT

AECOM303 EAST WACKER DRIVE,CHICAGO, IL 60601312.373.7700 tel 312.938.1109 faxwww.aecom.com

CIVILCHRISTOPHER B. BURKE, LTD.9575 W. HIGGINS ROADROSEMONT, IL. 60018 SUITE 600847.823.0500 tel 847.823.0520 fax

LANDSCAPEAECOM303 EAST WACKER DRIVE,CHICAGO, IL. 60601 SUITE 600312.373.7792 telwww.aecom.com

DATA TELCOM / AUDIO VISUALAECOM800 LASALLE AVEMINNEAPOLIS, MN 55402 SUITE 400612.376.2169 telwww.aecom.com

ELECTRONIC SECURITYAECOM2950 PROFESSIONAL PLACECOLORADO SPRINGS, CO 80904 SUITE 201719.386.8309 tel 719.386.8339 faxwww.aecom.com

FOOD SERVICES1 FOOD SERVICE231 HOMEWOOD DRIVEBOLINGBROOK, IL 60440630.783.9232 telhttp://s1foodservice.com/

9/22

/201

5 12

:26:

13 P

MC

:\Use

rs\c

anci

oa\D

ocum

ents

\LC

CH

_TO

WER

_T12

_CEN

TRAL

_can

cioa

.rvt

LAKE COUNTYCOURTHOUSEEXPANSION

WAUKEGAN, ILLINOIS 60085301 WASHINGTON STREET

ENLARGED TELECOM ROOMCEILING PLANS

2.T402

60288271

N OLE

KE

SCALE: 1/2" = 1'-0"2.T402 REF: 2.T201

AIDF CCT-1-1 - RM 1202 -ENLARGED TELECOM RCP

SCALE: 1/8" = 1'-0"2.T402

ELEVELS 1 THRU 9 IDF RISERCONDUIT ROUTE

SCALE: 1/2" = 1'-0"2.T402 REF: 2.T202

CIDF CCT-2-2 - RM 2201B -ENLARGED TELECOM RCP

TELECOM KEYNOTE LEGENDNOTE

# KEYNOTE TEXT1 CABLE TRAY SHALL BE A MINIMUM OF 2" HIGH X 12" WIDE. ALL CABLE TRAY SHALL BE A MINIMUM

OF 12" ON ALL SIDES FROM OTHER MECHANICAL, PLUMBING, ELECTRICAL AND LIGHTINGEQUIPMENT, DEVICES AND PATHWAYS; ETC. SEE SPECIFICATION AND REFER TO CABLEMANUFACTURERS PATHWAYS CABLE FILL FOR ADDITIONAL REQUIREMENTS.

2 PROVIDE (2) 4" CONDUITS WITH 3-CELL MESH INNERDUCT W/PULL STRINGS AND INSULATEDBUSHINGS ON EACH END BETWEEN TELECOMMUNICATIONS AND AUDIO VIDEO ROOMS ASSHOWN. CONDUIT SHALL BE A MINIMUM OF 12" ON ALL SIDES FROM OTHER MECHANICAL,PLUMBING, ELECTRICAL AND LIGHTING EQUIPMENT, DEVICES AND PATHWAYS; ETC. SEESPECIFICATION AND REFER TO CABLE MANUFACTURERS PATHWAYS CABLE FILL FOR ADDITIONALREQUIREMENTS.

3 ALL PENTHOUSE DATA CABLING (FIBER AND/OR CAT-6) TO BE ROUTED BACK TO 8TH FLOOR IDF.4 DATA AND A/V CONDUIT RISER LOCATIONS SHOWN FOR REFERENCE ONLY, REFER TO SHEET

2.T403 FOR FURTHER INFORMATION.

SEE 6/2.T409 FOR ADDITIONAL INFORMATION

SCALE: 1/2" = 1'-0"2.T402 REF: 2.T202

BIDF CCT-2-1 - RM 2006 -ENLARGED TELECOM RCP1

SCALE: 1/2" = 1'-0"2.T402 REF: 2.T204

D

IDF CCT-4-1, 5-1, 6-1, 7-1, 8-1, -RMS 4312, 5312, 6312, 7312ENLARGED TELECOM RCP

SCALE: 1/2" = 1'-0"2.T402 REF: 2.T208

FIDF CCT-9-1 - RM 8312 -ENLARGED TELECOM RCP

GENERAL TELECOM NOTESA. UNLESS OTHERWISE NOTED ALL TELECOM CONDUIT STUBS SHALL BE MINIMUM 1"

EMT ROUTED TO ABOVE CEILING WITH INSULATED BUSHINGS. UNLESS OTHERWISENOTED ALL WALL OUTLET BOXES FOR TELECOM TERMINATIONS SHALL BE 2-GANG,2-1/8" DEEP BOXES WITH SINGLE-GANG MUD RINGS.

B. ALL HORIZONTAL CABLING SHALL BE CATEGORY 6. REFER TO SPECIFICATION FORFURTHER INFORMATION AND REQUIREMENTS.

C. CONTRACTOR TO FIELD VERIFY INSTALLATION CONDITIONS PRIOR TO INSTALLATION.CONTRACTOR SHALL MAKE EVERY EFFORT TO PERFORM INSTALLATION FOLLOWINGLATEST GUIDELINES OF TIA-568, -569, AND -607.

D. CONTRACTOR TO FOLLOW MANUFACTURER'S RECOMMENDED INSTALLATIONMETHODS/PRACTICES FOR CAT 6.

E. ALL CABLING SHALL BE INSTALLED USING CABLE TRAY IN GENERAL PATHWAYS.F. REFER TO INTERIOR FINISH PLANS AND SPECIFICATION FOR FACEPLATES COLORS.G. ALL CATEGORY 6 CABLES WILL BE TERMINATED, LABELED AND TESTED. REFER TO

SPECIFICATION FOR FURTHER INFORMATION AND REQUIREMENTS.H. ALL CEILING DEVICES SHALL BE COORDINATED WITH ARCHITECTURAL AND

INTERIORS REFLECTED CEILING PLAN DRAWINGS.I. ALL WALL AND FURNITURE DEVICES SHALL BE COORDINATED WITH ARCHITECTURAL

AND INTERIORS DRAWINGS AND ELEVATIONS.J. ALL DUAL COMPARTMENT (NOMINAL AND LOW VOLTAGE) FLOOR BOXES SHALL BE

COORDINATED WITH ELECTRICAL DRAWINGS. FLOOR BOXES PROVIDED ANDINSTALLED BY ELECTRICAL CONTRACTOR.

K. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR RCP ALL DEVICES,EQUIPMENT AND CEILING TYPES.

SCALE: 1/2" = 1'-0"2.T402 REF: 2.T202

GAV-2-3 - RM 2108 - ENLARGEDTELECOM RCP

I/R DATE DESCRIPTION

2013.12.20 50% CCT GMP PACKAGE2014.02.12 50% TOWER GMP2014.03.31 TOWER BID SET2014.11.03 CONSOLIDATED GMP FINAL2015.09.22 ISSUE FOR CONSTRUCTION2015.10.16 FINAL ISSUED FOR CONSTRUCTION

SERVICES OF ILLINOIS, INC.

RFI 00224

dnash
Highlight
dnash
Highlight
dnash
Highlight
dnash
Highlight
dnash
Highlight
dnash
Highlight
dnash
Highlight
dnash
Highlight
Page 6: GENERAL TELECOM NOTES

0' -

8"

0' - 8"0' - 8"0' - 8"0' - 8"0' - 8"0' - 8"0' - 8"0' - 8"

LVL 1 DTALVL 2 DTA

LVL 3 DTALVL 4 DTA

LVL 5 DTALVL 6 DTA

LVL 7 DTALVL 8 DTA

SPAREPASS-THRU

LVL 2 AVLVL 2 AV

LVL 3 AVLVL 4 AV

LVL 5 AVLVL 6 AV

LVL 7 AVLVL 8 AV

SPAREPASS-THRU

3-F

3-13

2-143-14

2-14

2-F

T

3-F

2-7

3-7

2-7

2-F

2-5 2-6

CCT-2-4

4

2

2

2

E2.T402

52.T401

CCT-2-1

IDF

2006

CCT-2-2

CCT-2-3

4"C TO IDF2201B

4"C TO IDF2201B

4"C TO AV2108

4"C TO AV2108

1

0' -

8"

0' - 8"0' - 8"0' - 8"0' - 8"0' - 8"0' - 8"0' - 8"

LVL 2 AVLVL 3 AV

LVL 4 AVLVL 5 AV

LVL 6 AVLVL 7 AV

LVL 8 AV

SPAREPASS-THRU

2

4

CRAC

5

LVL 2 DATA

LVL 3 DATA

LVL 4 DATALVL 5 DATA

LVL 6 DATALVL 7 DATA

LVL 8 DATASPARE

PASS-THRU

T

3-F

3-13

2-152-143-14

2-14 2-15

2-F

E2.T402

52.T401

0' -

8"

0' - 8"0' - 8"0' - 8"0' - 8"0' - 8"0' - 8"0' - 8"0' - 8"

CCT-1-2

CCT-1-1

2

3BAS

4"C TO AV1314

4"C TO AV1314

1

CRAC5

IDF

1202

LVL 1 DTALVL 2 DTA

LVL 3 DTALVL 4 DTA

LVL 5 DTALVL 6 DTA

LVL 7 DTALVL 8 DTA

SPAREPASS-THRU

SPAREPASS-THRU

LVL 8 AVLVL 7 AV

LVL 6 AVLVL 5 AV

LVL 4 AV

LVL 3 AVLVL 2 AV

LVL 2 AV

T

3-13

2-152-143-14

2-14 2-15

4

E2.T402

0' -

8"

0' - 8"0' - 8"

0' - 8"0' - 8"

0' - 8"

CCT-4-3

CCT-4-2

CCT-4-1

2

T

CRAC

5

2-152-14

2-12 2-14 2-15

2-F

H4.2

H4.1

4

E2.T402

0' -

8"CCT-8-1

CCT-8-2

CCT-8-3

2

4

14"C TO AV

8402

4"C TO AV8402

CRAC

5

4"C PTHDATA

4"C PTHDATA

SPAREPASS-THRU

SPAREPASS-THRU

2-152-14

2-14 2-15

2-F

IDF

8312

0' - 8"

LVL 8 AV

LVL 8 DATA

T

H1.1

1

4"C TO IDF1202

4"C TO IDF1202

4

3- 11

2-H.5

4S,4M

A/V CLOSET

1314

2-11

H9.1

2-7

2-H

2-4.5

4M,4S

A/V ROOM

8402

2-5 2-6

6

4"C TO IDF8312

4"C TO IDF8312

AV EQUIP

2108

4

T

3-J 2-J

2-H.7

2-H.5

4S,4M

H4.2

6

2-10

PROJECT

CLIENT

REGISTRATION

LAKE COUNTY18 N. COUNTY STREETWAUKEGAN, ILLINOIS847.377.2929 tel 847.984.5889 fax

STRUCTURALAECOM999 TOWN AND COUNTRY ROADORANGE, CA 92868312.373.7700 tel 312.938.1109 faxwww.aecom.com

MEP/FPSYSKA HENNESSY GROUP, INC.330 N. WABASH AVE.CHICAGO, IL. 60611 SUITE 1505312.588.3561 tel 312.588.3579 faxwww.syska.com

CODE/LIFE SAFETYROLF JENSEN & ASSOCIATED, INC.600 WEST FULTON STREETCHICAGO, IL. 60661312.879.7200 tel 312.879.7200 faxwww.rjainc.com

ISSUE/REVISION

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

Last

Plo

tted:

File

nam

e:

Printed on ___% Post-ConsumerRecycled Content Paper

ARC

H E

1 30

" x 4

2"Pr

ojec

t Man

agem

ent I

nitia

ls:

Che

cked

:Ap

prov

ed:

123456

A

B

C

D

E

6 5 4 3 2 1

CONSULTANTS

ARCHITECT

AECOM303 EAST WACKER DRIVE,CHICAGO, IL 60601312.373.7700 tel 312.938.1109 faxwww.aecom.com

CIVILCHRISTOPHER B. BURKE, LTD.9575 W. HIGGINS ROADROSEMONT, IL. 60018 SUITE 600847.823.0500 tel 847.823.0520 fax

LANDSCAPEAECOM303 EAST WACKER DRIVE,CHICAGO, IL. 60601 SUITE 600312.373.7792 telwww.aecom.com

DATA TELCOM / AUDIO VISUALAECOM800 LASALLE AVEMINNEAPOLIS, MN 55402 SUITE 400612.376.2169 telwww.aecom.com

ELECTRONIC SECURITYAECOM2950 PROFESSIONAL PLACECOLORADO SPRINGS, CO 80904 SUITE 201719.386.8309 tel 719.386.8339 faxwww.aecom.com

FOOD SERVICES1 FOOD SERVICE231 HOMEWOOD DRIVEBOLINGBROOK, IL 60440630.783.9232 telhttp://s1foodservice.com/

9/22

/201

5 12

:28:

01 P

MC

:\Use

rs\c

anci

oa\D

ocum

ents

\LC

CH

_TO

WER

_T12

_CEN

TRAL

_can

cioa

.rvt

LAKE COUNTYCOURTHOUSEEXPANSION

WAUKEGAN, ILLINOIS 60085301 WASHINGTON STREET

ENLARGED TELECOM ROOMFLOOR PLANS

2.T403

60288271

N OLE

KE

SCALE: 1/2" = 1'-0"2.T403 REF: 2.T401

1

MDF CCT-B-1 - RM B1008 -TELECOM ENLARGED FLOORPENETRATIONS

SCALE: 1/2" = 1'-0"2.T403 REF: 2.T102

4IDF CCT-2-2 - RM 2201B -ENLARGED FLOOR PLAN

0 2' 4' 6'1'SCALE: 1/2" = 1'-0"

TELECOM KEYNOTE LEGENDNOTE # KEYNOTE TEXT

1 CONDUIT ROUTING IS SHOWN FOR REFERENCE ONLY. CONDUIT SHALLBE PROVIDE AND INSTALLED BY ELECTRICAL CONTRACTOR. LOWVOLTAGE CONTRACTOR TO PROVIDE 3-CELL MESH INNERDUCT ANDINSTALLED BY ELECTRICAL CONTRACTOR. REFER TO ELECTRICALSHEETS [E SERIES] FOR EXACT LOCATIONS AND ROUTING PATH.

2 8'T x 4'W FIRE TREATED BACKBOARDS AT THIS LOCATION PROVIDED BYDIVISION 25. COORDINATE WITH DIVISION 25 FOR EXACT LOCATION.WHERE CONDUITS PENETRATE FLOOR CABLING SHALL BE SECURED TOLADDER RACK WITH VELCRO STRAPS WITH LIKE SYSTEMS BUNDLEDTOGETHER. ALL FIRE FIRE RATINGS OF FLOOR PENETRATIONS SHALL BEMAINTAINED PER ALL ENFORCED BUILDING CODES AND ADOPTEDAMENDMENTS.

3 PROVIDE 2 DATA DROPS TO BACNET/IP CONTROLLER. COORDINATE WITHDIVISION 23/25 FOR EXACT LOCATION AND REQUIREMENTS.

4 TGB GROUND BAR AT THIS LOCATION PROVIDED BY DIVISION 26.COORDINATE WITH DIVISION 26 FOR EXACT LOCATION.

5 PROVIDE 1 DATA DROP FOR CRAC UNIT BACNET/IP CONTROLLERPROVIDED BY DIVISION 23. COORDINATE WITH DIVISION 23 FOR EXACTLOCATION AND REQUIREMENTS.

6 PROVIDE (2) 4" CONDUITS WITH 3-CELL MESH INNERDUCT W/PULLSTRINGS AND INSULATED BUSHINGS ON EACH END BETWEENTELECOMMUNICATIONS AND AUDIO VIDEO ROOMS AS SHOWN. CONDUITSHALL BE A MINIMUM OF 12" ON ALL SIDES FROM OTHER MECHANICAL,PLUMBING, ELECTRICAL AND LIGHTING EQUIPMENT, DEVICES ANDPATHWAYS; ETC. SEE SPECIFICATION AND REFER TO CABLEMANUFACTURERS PATHWAYS CABLE FILL FOR ADDITIONALREQUIREMENTS.

SCALE: 1/2" = 1'-0"2.T403 REF: 2.T102

3IDF CCT-2-1 - RM 2006 -ENLARGED FLOOR PLAN

SCALE: 1/2" = 1'-0"2.T403 REF: 2.T101

2IDF CCT-1-1 - RM 1202 -ENLARGED FLOOR PLAN

2.T403 REF: 2.T104 SCALE: 1/2" = 1'-0"

5IDF CCT-4-1, 5-1, 6-1, 7-1 - RMS 4312, 5312, 6312, 7312 ENLARGEDFLOOR PLAN

SCALE: 1/2" = 1'-0"2.T403 REF: 2.T108

6IDF CCT-8-1 - RM 8312 -ENLARGED FLOOR PLAN

SCALE: 1/2" = 1'-0"2.T403 REF: 2.T101

7AV-1-1 - RM 1314 - ENLARGEDFLOOR PLAN

SCALE: 1/2" = 1'-0"2.T403 REF: 2.T108

8AV-9-1 - RM 9411 - ENLARGEDFLOOR PLAN

SCALE: 1/2" = 1'-0"2.T403 REF: 2.T102

9AV-2-3 - RM 2108 - ENLARGEDFLOOR PLAN

GENERAL TELECOM NOTESA. UNLESS OTHERWISE NOTED ALL TELECOM CONDUIT STUBS SHALL BE MINIMUM 1"

EMT ROUTED TO ABOVE CEILING WITH INSULATED BUSHINGS. UNLESS OTHERWISENOTED ALL WALL OUTLET BOXES FOR TELECOM TERMINATIONS SHALL BE 2-GANG,2-1/8" DEEP BOXES WITH SINGLE-GANG MUD RINGS.

B. ALL HORIZONTAL CABLING SHALL BE CATEGORY 6. REFER TO SPECIFICATION FORFURTHER INFORMATION AND REQUIREMENTS.

C. CONTRACTOR TO FIELD VERIFY INSTALLATION CONDITIONS PRIOR TO INSTALLATION.CONTRACTOR SHALL MAKE EVERY EFFORT TO PERFORM INSTALLATION FOLLOWINGLATEST GUIDELINES OF TIA-568, -569, AND -607.

D. CONTRACTOR TO FOLLOW MANUFACTURER'S RECOMMENDED INSTALLATIONMETHODS/PRACTICES FOR CAT 6.

E. ALL CABLING SHALL BE INSTALLED USING CABLE TRAY IN GENERAL PATHWAYS.F. REFER TO INTERIOR FINISH PLANS AND SPECIFICATION FOR FACEPLATES COLORS.G. ALL CATEGORY 6 CABLES WILL BE TERMINATED, LABELED AND TESTED. REFER TO

SPECIFICATION FOR FURTHER INFORMATION AND REQUIREMENTS.H. ALL CEILING DEVICES SHALL BE COORDINATED WITH ARCHITECTURAL AND

INTERIORS REFLECTED CEILING PLAN DRAWINGS.I. ALL WALL AND FURNITURE DEVICES SHALL BE COORDINATED WITH ARCHITECTURAL

AND INTERIORS DRAWINGS AND ELEVATIONS.J. ALL DUAL COMPARTMENT (NOMINAL AND LOW VOLTAGE) FLOOR BOXES SHALL BE

COORDINATED WITH ELECTRICAL DRAWINGS. FLOOR BOXES PROVIDED ANDINSTALLED BY ELECTRICAL CONTRACTOR.

K. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR RCP ALL DEVICES,EQUIPMENT AND CEILING TYPES.

I/R DATE DESCRIPTION

2013.12.20 50% CCT GMP PACKAGE2014.02.12 50% TOWER GMP2014.03.31 TOWER BID SET2014.11.03 CONSOLIDATED GMP FINAL2015.09.22 ISSUE FOR CONSTRUCTION2015.10.16 FINAL ISSUED FOR CONSTRUCTION

SERVICES OF ILLINOIS, INC.

dnash
Highlight
dnash
Highlight
dnash
Highlight
dnash
Highlight
dnash
Highlight
dnash
Highlight
dnash
Highlight
dnash
Highlight
dnash
Highlight
dnash
Highlight
dnash
Highlight
dnash
Highlight
dnash
Highlight
dnash
Highlight
dnash
Highlight
Page 7: GENERAL TELECOM NOTES

UP

UP

C C C

1

11

11

1

1 1

112

3

44

4 4 4 4

2D

2D

2D

2D1D

4D

4D 4D

4D 4D 4D

4D 4D

4D 4D

4D 4D

2D

2D 2D

2D 2D 2D

2D2D

1V,2D1V,2D 1V,2D1V,2D1V,2D

1V,2D1V,2D 1V,2D1V,2D

3-H

3-93-5

2-H

2-152-14

3-7

3- 113- 5 3- 7.42-2 2-4 2-7 2-7.4 2-9 2-12 2-142-15

2-H

2-4.5

2D

1D 1D 1D 1D 1D 1D

2D 2D

3

1D

3

1D

3

1D

3

1D

3

1D

3

1D

3

1D

1D 1D 1D

3

1D

3

3

1D

3

3

1D

3

3

1D

3

3

1D

3

3

1D

3

3

1D

3

3

1D

3

1D

1D 1D

1D

1D

1D

1D

1D

2-3 2-8 2-10 2-112-5 2-6

4

1

1 22

2

2

2

2

2

4

2

2

2

2

4

KEYPLAN LEGEND:0 - CAMPUS/ SITE1 - (E) BABCOX2 - COURT TOWER3 - TUNNEL4 - (E) COURT ADMIN5 - (E) BRIDGE

N

PROJECT

CLIENT

REGISTRATION

LAKE COUNTY18 N. COUNTY STREETWAUKEGAN, ILLINOIS847.377.2929 tel 847.984.5889 fax

STRUCTURALAECOM999 TOWN AND COUNTRY ROADORANGE, CA 92868312.373.7700 tel 312.938.1109 faxwww.aecom.com

MEP/FPSYSKA HENNESSY GROUP, INC.330 N. WABASH AVE.CHICAGO, IL. 60611 SUITE 1505312.588.3561 tel 312.588.3579 faxwww.syska.com

CODE/LIFE SAFETYROLF JENSEN & ASSOCIATED, INC.600 WEST FULTON STREETCHICAGO, IL. 60661312.879.7200 tel 312.879.7200 faxwww.rjainc.com

ISSUE/REVISION

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

Last

Plo

tted:

File

nam

e:

Printed on ___% Post-ConsumerRecycled Content Paper

ARC

H E

1 30

" x 4

2"Pr

ojec

t Man

agem

ent I

nitia

ls:

Che

cked

:Ap

prov

ed:

123456

A

B

C

D

E

6 5 4 3 2 1

CONSULTANTS

ARCHITECT

AECOM303 EAST WACKER DRIVE,CHICAGO, IL 60601312.373.7700 tel 312.938.1109 faxwww.aecom.com

CIVILCHRISTOPHER B. BURKE, LTD.9575 W. HIGGINS ROADROSEMONT, IL. 60018 SUITE 600847.823.0500 tel 847.823.0520 fax

LANDSCAPEAECOM303 EAST WACKER DRIVE,CHICAGO, IL. 60601 SUITE 600312.373.7792 telwww.aecom.com

DATA TELCOM / AUDIO VISUALAECOM800 LASALLE AVEMINNEAPOLIS, MN 55402 SUITE 400612.376.2169 telwww.aecom.com

ELECTRONIC SECURITYAECOM2950 PROFESSIONAL PLACECOLORADO SPRINGS, CO 80904 SUITE 201719.386.8309 tel 719.386.8339 faxwww.aecom.com

KEY PLANSCALE: N.T.S.

FOOD SERVICES1 FOOD SERVICE231 HOMEWOOD DRIVEBOLINGBROOK, IL 60440630.783.9232 telhttp://s1foodservice.com/

1A1C

1B

35

4

2

9/22

/201

5 1:

43:3

3 PM

C:\U

sers

\can

cioa

\Doc

umen

ts\L

CC

H_T

OW

ER_T

12_C

ENTR

AL_c

anci

oa.rv

t

LAKE COUNTYCOURTHOUSEEXPANSION

WAUKEGAN, ILLINOIS 60085301 WASHINGTON STREET

ENLARGED COURTS LEVELS 5THRU 7 TYPICAL DEVICELOCATIONS

2.T404

60288271

Che

cker

2.T404 REF: 2.T104 SCALE: 1/4" = 1'-0"

1 STANDARD COURTS LEVELS 5 THRU 7 TYPICAL DEVICE LOCATIONS

GENERAL TELECOM NOTESA. UNLESS OTHERWISE NOTED ALL TELECOM CONDUIT STUBS SHALL BE MINIMUM 1"

EMT ROUTED TO ABOVE CEILING WITH INSULATED BUSHINGS. UNLESS OTHERWISENOTED ALL WALL OUTLET BOXES FOR TELECOM TERMINATIONS SHALL BE 2-GANG,2-1/8" DEEP BOXES WITH SINGLE-GANG MUD RINGS.

B. ALL HORIZONTAL CABLING SHALL BE CATEGORY 6. REFER TO SPECIFICATION FORFURTHER INFORMATION AND REQUIREMENTS.

C. CONTRACTOR TO FIELD VERIFY INSTALLATION CONDITIONS PRIOR TO INSTALLATION.CONTRACTOR SHALL MAKE EVERY EFFORT TO PERFORM INSTALLATION FOLLOWINGLATEST GUIDELINES OF TIA-568, -569, AND -607.

D. CONTRACTOR TO FOLLOW MANUFACTURER'S RECOMMENDED INSTALLATIONMETHODS/PRACTICES FOR CAT 6.

E. ALL CABLING SHALL BE INSTALLED USING CABLE TRAY IN GENERAL PATHWAYS.F. REFER TO INTERIOR FINISH PLANS AND SPECIFICATION FOR FACEPLATES COLORS.G. ALL CATEGORY 6 CABLES WILL BE TERMINATED, LABELED AND TESTED. REFER TO

SPECIFICATION FOR FURTHER INFORMATION AND REQUIREMENTS.H. ALL CEILING DEVICES SHALL BE COORDINATED WITH ARCHITECTURAL AND

INTERIORS REFLECTED CEILING PLAN DRAWINGS.I. ALL WALL AND FURNITURE DEVICES SHALL BE COORDINATED WITH ARCHITECTURAL

AND INTERIORS DRAWINGS AND ELEVATIONS.J. ALL DUAL COMPARTMENT (NOMINAL AND LOW VOLTAGE) FLOOR BOXES SHALL BE

COORDINATED WITH ELECTRICAL DRAWINGS. FLOOR BOXES PROVIDED ANDINSTALLED BY ELECTRICAL CONTRACTOR.

K. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR RCP ALL DEVICES,EQUIPMENT AND CEILING TYPES.

TELECOM KEYNOTE LEGENDNOTE

# KEYNOTE TEXT1 SEE DETAIL 2/2.T506 FOR MOBILE CART INTERFACE DETAIL. CABLING TO BE EXTENDED

FROM CORRESPONDING FLOOR IDF WITH ALL TERMINATIONS BY DATA CONTRACTOR.2 PROVIDE (1) 1-1/4"C FOR DATA CABLING FROM FLOOR POKE-THRU TO NEAREST WALL,

ROUTED UP WALL CAVITY TO ABOVE ACCESSIBLE CEILING W/INSULATED BUSHING,EXTEND CABLING TO NEAREST CABLE TRAY ROUTED BACK TO CORRESPONDING FLOORIDF. POKE-THRU PROVIDED AND INSTALLED BY ELECTRICAL.

3 SEE DETAIL 1/2.T506 FOR TABLE TOP MEDIA INTERFACE DETAIL. CABLING TO BEEXTENDED FROM CORRESPONDING FLOOR IDF WITH ALL TERMINATIONS BY DATACONTRACTOR.

4 TYPICAL OF ALL OUTLETS WITHIN JUDGE BENCH MILLWORK, COORDINATE OUTLET ANDBACKBOX INSTALLATION WITH MILLWORK PROVIDER. ROUTE CABLING UTILIZING FLEXCONDUIT FROM MILLWORK OUTLETS UNDER BENCH PLATFORM TO WALL. ROUTECABLING UP WALL TO ABOVE CEILING WITH EMT CONDUIT.

I/R DATE DESCRIPTION

2014.02.12 50% TOWER GMP2014.03.31 TOWER BID SET2014.11.03 CONSOLIDATED GMP FINAL2015.09.22 ISSUE FOR CONSTRUCTION2015.10.16 FINAL ISSUED FOR CONSTRUCTION

SERVICES OF ILLINOIS, INC.

dnash
Highlight
dnash
Highlight
dnash
Highlight
Page 8: GENERAL TELECOM NOTES

2

1

NOTESA. PROVIDE RADIUS DROP CONTROL COMPONENTS AT ALL CABLE ELEVATION CHANGES.

DETAIL NOTES1. BASKET TRAY CABLE DROP OUT ASSEMBLY, OBSERVING ANDFOLLOWING ALL MANUFACTURER AND TIA/EIA OUTSIDE BEND RADIUS.2. BASKET TRAY.

NOTESA. PROVIDE RADIUS DROP CONTROL COMPONENTS AT ALL CABLEELEVATION CHANGES.DETAIL NOTES1. BASKET TRAY CABLE DROP OUT ASSEMBLY, OBSERVING ANDFOLLOWING ALL MANUFACTURER AND TIA/EIA OUTSIDE BEND RADIUS.2. BASKET TRAY WATERFALL FOR CABLE EXIT, OBSERVING ANDFOLLOWING ALL MANUFACTURER AND TIA/EIA OUTSIDE BEND RADIUS.3. FLEXIBLE WIRE BASKET-TYPE CABLE TRAY.

3

1

2

ACM-114C-110A-D15

TENANT ID

ORIGIN (IDF ROOM/RACK#)

ROOM/OUTLET #

PORT #

LABEL BETWEEN 4"=12"OF PATCH PANEL ANDWITHIN 2" AT OUTLET

.

ACM-131K16-F001-IDF01

TENANT ID

RACK ID (ROOM/RACK #)

CABLE BUNDLE # (F=FIBER)

RACK ID (ROOM/RACK #)

LABEL BETWEEN 4"-8" AT PANEL

.

DETAIL NOTES1. SPLICE HARDWARE ASSEMBLY.

- TOP WASHER.- BOTTOM WASHER.- CARRIAGE BOLT.- FINNED NOT OR NUT AND LOCK WASHER.

2. GROUND BOLT ASSEMBLY.3. #6AWG GROUND WIRE.

31

2

THREADED RODSUPPORTED FROMSTRUCTURE ABOVE(TYP.)

HUNG CEILING

TOP OF FLOOR HALLWAY/CORRIDOR

WALL

WALL

RECESSED FLOOR BOXIN SLAB - TYPICAL

CONDUIT(1") (U.N.O.)

STEEL COMPRESSIONCOUPLING

WRENCH TIGHT

EMT CONNECTOR

INSULATED BUSHING(TYPICAL) 2-GANG RECESSED

STEEL JUNCTION BOX(TYPICAL)

COMMUNICATION OUTLETFACEPLATE W/SINGLE-GANG MUD-

RING (TYPICAL)

CABLE BUNDLESWITH CABLEHANGAR

RECESSEDHALLWAY LIGHTING(TYPICAL)

BUSHING (NYLON)

TO SUPPORT CABLE TRAY, UTILIZETHREADED ROD ANCHORED TO DECKABOVE AND/OR WALL-MOUNTBRACKETS. UTILIZE CHANNEL STRUT TOSUPPORT TRAY WHEN OFFSET RODSARE PLACED TO AVOID DUCTS ANDOTHER UTILITY PIPING.

CABLE TRAY (OR J-HOOKS WHERESPECIFICALLY NOTED)

CONDUIT IN WALLOR FURRED OUT

COLUMN (1")(U.N.O.)

DETAIL NOTESA. STUB END OF CONDUIT TO CLOSEST CABLE TRAY OR J-HOOK PATHWAY.

B. TELECOMMUNICATION OUTLET BOXES SHALL BE 2-GANG RECESSEDJUNCTION BOXES WITH SINGLE-GANG MUD RINGS, UNLESS OTHERWISENOTED.

C. UNLESS OTHERWISE NOTED, ALL CONDUIT FOR HORIZONTALTELECOMMUNICATIONS CABLING SHALL BE A MINIMUM OF 1" EMT, STUBBEDABOVE ACCESSIBLE CEILING W/INSULATED BUSHING. SEE CONDUIT SIZINGTABLE FOR ADDITIONAL INFORMATION.

D. TELECOMMUNICATIONS WALL OUTLETS SHALL BE ALIGNED WITH ADJACENTELECTRICAL RECEPTACLES WHERE THEY ARE LOCATED WITHIN THE SAMEVICINITY IN A NEAT AND WORKMANSHIP LIKE MANNER.

E. FOR FLOOR LOCATIONS, COORDINATE RACEWAY FORTELECOMMUNICATIONS OUTLET(S) WITH ELECTRICAL RECEPTACLELOCATIONS AND ENCLOSURES.

F. ALL CONDUITS SHALL BE EQUIPPED WITH PULL STRINGS.

G. ALL TELECOMMUNICATIONS EXPOSED (FREE-AIR)COPPER TWISTED PAIRCABLING (UNSHIELDED, SHIELDED; ETC) SHALL NOT BE WITHIN 12" OF ANYFLUORESCENT LIGHTING AND/OR LIGHTING BALLASTS.

H. COORDINATE WITH POWERED FURNITURE SUPPLIER FOR ANY OUTLETS TOBE INSTALLED ON/WITHIN POWERED FURNITURE.

TO SUPPORT CABLE BUNDLESWITH CABLE DROP WIRE

HANGAR, UTILIZE HANGERCLIPS AND DROP WIRE

ANCHORED TO DECK ABOVE.

PROVIDE J-HOOK ASSEMBLIESSPACED 5'-0" OC BETWEEN

STUBBED CONDUIT ANDNEAREST TRAY.

TYPICAL CONDUITTRANSITION INTO IDF.PROVIDE MECHANICALRE-ENTERABLE FIRESTOPFOR ALL CONDUIT/CABLETRAY SHOWN ROUTEDTHROUGH TELECOMROOM WALLS.

TYPICALCOMMUNICATIONSFIBER OPTIC ORCOPPER CABLING.

LADDER RACK &SUPPORTS

TYPICAL HORIZONTALCOMMUNICATIONSCABLINGFROM WORKSTATIONS.

INSULATEDBUSHINGPROVIDED ONEACH END.

TYPICAL STRUTCONDUITSTRAP.

UNISTRUTATTACHED TOWALL

DETAIL NOTE:SEE PROJECT SPECIFICATIONSFOR ADDITIONAL MATERIAL,COLOR, TERMINATION ANDINSTALLATION INFORMATION.

TELECOMMUNICATION ROOM WORK AREA

VOICE AND DATA UTPOUTLET-TYPICAL

CATEGORY 6 4-PAIR,PLENUM RATED, UTPCABLE. SEETELECOM DETAILSFOR CABLE COLORS

CATEGORY 6 MODULAR-TO-110PATCH PANEL, RACK-MOUNTED.

-TYPICAL

TYPICAL WIRE MESH TRAY.LADDER RACK IN TELECOM ROOMS ONLY.

TYPICAL TELECOM CABLE

PENETRATION 4" DIAMETER MECHANICAL RE-ENTERABLE FIRESTOP.TOTAL ALLOWABLE CABLE FILL OF FIRESTOP MUST BE GREATER THANCABLE TRAY CABLE FILL.

NOTE:

1.

2.

SEAL ALL PATHWAYS WITH ONLY UL LISTED FIRESTOP SYSTEMS.

3.

PRECISELY FOLLOW MANUFACTURERS INSTALLATION DIRECTIONS.

4.

USE APPROPRIATE FIRESTOP SYSTEM DESIGNATED FOR THE PENETRATION.

USE FIRESTOP SYSTEM THAT AT LEAST EQUALS FIRE RATING OF PARTITION.

NOTES:MAXIMUM DISTANCE BETWEEN SUPPORTSSHALL BE NO GREATER THAN 5'.

DETAIL NOTES:1. SUPPORT CHANNEL TO WALL.2. CABLE OR BASKET TRAY.3. CABLE OR BASKET TRAY HOLD DOWN PLATE.

1

2

3

PROJECT

CLIENT

REGISTRATION

LAKE COUNTY18 N. COUNTY STREETWAUKEGAN, ILLINOIS847.377.2929 tel 847.984.5889 fax

STRUCTURALAECOM999 TOWN AND COUNTRY ROADORANGE, CA 92868312.373.7700 tel 312.938.1109 faxwww.aecom.com

MEP/FPSYSKA HENNESSY GROUP, INC.330 N. WABASH AVE.CHICAGO, IL. 60611 SUITE 1505312.588.3561 tel 312.588.3579 faxwww.syska.com

CODE/LIFE SAFETYROLF JENSEN & ASSOCIATED, INC.600 WEST FULTON STREETCHICAGO, IL. 60661312.879.7200 tel 312.879.7200 faxwww.rjainc.com

ISSUE/REVISION

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

Last

Plo

tted:

File

nam

e:

Printed on ___% Post-ConsumerRecycled Content Paper

ARC

H E

1 30

" x 4

2"Pr

ojec

t Man

agem

ent I

nitia

ls:

Che

cked

:Ap

prov

ed:

123456

A

B

C

D

E

6 5 4 3 2 1

CONSULTANTS

ARCHITECT

AECOM303 EAST WACKER DRIVE,CHICAGO, IL 60601312.373.7700 tel 312.938.1109 faxwww.aecom.com

CIVILCHRISTOPHER B. BURKE, LTD.9575 W. HIGGINS ROADROSEMONT, IL. 60018 SUITE 600847.823.0500 tel 847.823.0520 fax

LANDSCAPEAECOM303 EAST WACKER DRIVE,CHICAGO, IL. 60601 SUITE 600312.373.7792 telwww.aecom.com

DATA TELCOM / AUDIO VISUALAECOM800 LASALLE AVEMINNEAPOLIS, MN 55402 SUITE 400612.376.2169 telwww.aecom.com

ELECTRONIC SECURITYAECOM2950 PROFESSIONAL PLACECOLORADO SPRINGS, CO 80904 SUITE 201719.386.8309 tel 719.386.8339 faxwww.aecom.com

FOOD SERVICES1 FOOD SERVICE231 HOMEWOOD DRIVEBOLINGBROOK, IL 60440630.783.9232 telhttp://s1foodservice.com/

9/22

/201

5 12

:28:

46 P

MC

:\Use

rs\c

anci

oa\D

ocum

ents

\LC

CH

_TO

WER

_T12

_CEN

TRAL

_can

cioa

.rvt

LAKE COUNTYCOURTHOUSEEXPANSION

WAUKEGAN, ILLINOIS 60085301 WASHINGTON STREET

TELECOM DETAILS

2.T501

60288271

Che

cker

SCALE: N.T.S.2.T501

1CABLE TRAY CABLE FALLOUTDETAIL

SCALE: N.T.S.2.T501

2 CABLE TRAY WATERFALL DETAILSCALE: N.T.S.2.T501

3 TWISTED PAIR CABLE LABELINGSCALE: N.T.S.2.T501

4 FIBER OPTIC CABLE LABELINGSCALE: N.T.S.2.T501

5 CABLE TRAY DETAIL W/GND

SCALE: N.T.S.2.T501

6

TELECOMMUNICATIONSINFRASTRUCTURE ANDASSEMBLIES ROUGH-IN DETAIL

SCALE: N.T.S.2.T501

7LADDER/CABLE TRAYTRANSITION

SCALE: N.T.S.2.T501

8TELECOM WORKSTATION CABLEDETAIL

SCALE: N.T.S.2.T501

9FIRE RATED WALL PENETRATIONDETAIL

I/R DATE DESCRIPTION

2013.12.20 50% CCT GMP PACKAGE2014.02.12 50% TOWER GMP2014.03.31 TOWER BID SET2014.11.03 CONSOLIDATED GMP FINAL2015.09.22 ISSUE FOR CONSTRUCTION

SCALE: N.T.S.2.T501

10VERTICAL CABLE TRAYSUPPORT DETAIL

2015.10.16 FINAL ISSUED FOR CONSTRUCTION

SERVICES OF ILLINOIS, INC.

RFI-1121

RFI-1161

Page 9: GENERAL TELECOM NOTES

OUTLET LABEL

DATA 1

1 POSITIONFACEPLATE

1 2 3 4 5 6 7 8

PIN#54123678

PAIR COLORT1-W/BLR1-BL/WT2-W/OR2-O/WT3-W/GRR3-GR/WT4-W/BRR4-BR/W

JACK TYPEDATA 1

JACK COLORBLUE

CABLECAT 6/BLUE

RJ-45(T568A)

PR3 PR4

PR2

PR1

DRAWINGSYMBOL

XXXX-XX

XXXX-XX

NOTE:VERIFY W/PLANS FORFLUSH IN CEILING ORABOVE CEILINGMOUNTING LOCATIONS

1 2 3 4 5 6 7 8

PIN#54123678

PAIR COLORT1-W/BLR1-BL/WT2-W/OR2-O/WT3-W/GRR3-GR/WT4-W/BRR4-BR/W

JACK TYPEDATA 1

JACK COLORBLUE

CABLECAT 6/BLUE

RJ-45(T568A)

PR3 PR4

PR2

PR1

DRAWINGSYMBOL

AP

MALE RJ-45TERMINATEDDIRECTLY ATACCESS POINT,ROUTER OR WIFIHUB

GROMMETEDCABLE PASS-THRUTO FURNITUREEQUIPMENT

GROMMET HOLEFACEPLATE

DRAWINGSYMBOL

J

NOTE:THIS OUTLETCONFIGURATION APPLIESTO SYSTEM FURNITURELOCATIONS AND EQUIPMENTLOCATIONS. FOR SYSTEMFURNITURE LOCATIONS, THISCONFIGURATION WILL SERVE ASA PASS-THRU ONLY AND CABLESWILL TERMINATE AT FURNITUREOUTLET. COORDINATE CABLEINSTALLATION WITH SYSTEMFURNITURE INSTALLER.

PASS-THRU SIZED BASED ONCABLE QUANTITIES AT EACHLOCATION SHOWN ON PLANS.PROVIDE PROTECTIVE BRUSHEDGROMMET AND MESH-CELLINNERDUCT FROM WITHINGROMMETED BOX ROUTEDTHROUGH FURNITURE SYSTEM.

P

OUTLET LABEL

PROJECTOR 1

1 POSITIONFACEPLATE

1 2 3 4 5 6 7 8

PIN#54123678

PAIR COLORT1-W/BLR1-BL/WT2-W/OR2-O/WT3-W/GRR3-GR/WT4-W/BRR4-BR/W

JACK TYPEPROJECTOR 1

JACK COLORBLUE

CABLECAT 6/BLUE

RJ-45(T568A)

PR3 PR4

PR2

PR1

DRAWINGSYMBOL

XXXX-XX

XXXX-XX

NOTE:VERIFY W/PLANS FORFLUSH IN CEILING ORABOVE CEILINGMOUNTING LOCATIONS,THIS TERMINATION ISFOR THE DATACONNECTION TO THEPROJECTOR AND NOTTHE A/V CONNECTION.SEE A/V SHEETS FORPROJECTOR CABLINGAND TERMINATIONREQUIREMENTS.

TV

OUTLET LABEL

(IPTV) DATA 1

1 POSITIONFACEPLATE

1 2 3 4 5 6 7 8

PIN#54123678

PAIR COLORT1-W/BLR1-BL/WT2-W/OR2-O/WT3-W/GRR3-GR/WT4-W/BRR4-BR/W

JACK TYPEDATA 1

JACK COLORBLUE

CABLECAT 6/BLUE

RJ-45(T568A)

PR3 PR4

PR2

PR1

DRAWINGSYMBOL

XXXX-XX

XXXX-XX

NOTE:COORDINATE WITH AVSHEETS FORNECESSARY LOCATIONS

OUTLET LABEL

DATA 1

1 POSITIONFACEPLATE

1 2 3 4 5 6 7 8

PIN#54123678

PAIR COLORT1-W/BLR1-BL/WT2-W/OR2-O/WT3-W/GRR3-GR/WT4-W/BRR4-BR/W

JACK TYPEDATA 1

JACK COLORBLUE

CABLECAT 6/BLUE

RJ-45(T568A)

PR3 PR4

PR2

PR1

DRAWINGSYMBOL

XXXX-XX

XXXX-XX

1D

C

THIS OUTLETCONFIGURATION APPLIESTO ALL WALL MOUNTVOIP/PHONELOCATIONS. SHALL BEMOUNTED AT +48" A.F.F.UNLESS OTHERWISE NOTED

OUTLET LABEL

VOICE 1

1 POSITIONFACEPLATE

1 2 3 4 5 6 7 8

PIN#54123678

PAIR COLORT1-W/BLR1-BL/WT2-W/OR2-O/WT3-W/GRR3-GR/WT4-W/BRR4-BR/W

JACK TYPEVOICE 1

JACK COLORIVORY

CABLECAT 6A/GRAY

RJ-45(T568A)

PR3 PR4

PR2

PR1

DRAWINGSYMBOL

XXXX-XX

XXXX-XX

1V

DATA 1

VOICE 1

BLANK/SPARE 1

BLANK/SPARE 1

OUTLET LABEL

4 POSITIONFACEPLATE

1 2 3 4 5 6 7 8

PIN#54123678

PAIR COLORT1-W/BLR1-BL/WT2-W/OR2-O/WT3-W/GRR3-GR/WT4-W/BRR4-BR/W

JACK TYPEDATA 1VOICE 1

JACK COLORBLUEIVORY

CABLECAT 6/BLUECAT 6A/GRAY

RJ-45(T568A)

PR3 PR4

PR2

PR1

DRAWINGSYMBOL

XXXX-XX

XXXX-XX

1V,1D

DATA 1

VOICE 1

DATA 2

BLANK/SPARE 1

OUTLET LABEL

4 POSITIONFACEPLATE

1 2 3 4 5 6 7 8

PIN#54123678

PAIR COLORT1-W/BLR1-BL/WT2-W/OR2-O/WT3-W/GRR3-GR/WT4-W/BRR4-BR/W

JACK TYPEDATA 1DATA 2VOICE 1

JACK COLORBLUEN/AIVORY

CABLECAT 6/BLUECAT 6/BLUE/WHITECAT 6A/GRAY

RJ-45(T568A)

PR3 PR4

PR2

PR1

DRAWINGSYMBOL

XXXX-XX

XXXX-XX

1V,2D

DATA 1

VOICE 1

DATA 2

VOICE 2

OUTLET LABEL

4 POSITIONFACEPLATE

1 2 3 4 5 6 7 8

PIN#54123678

PAIR COLORT1-W/BLR1-BL/WT2-W/OR2-O/WT3-W/GRR3-GR/WT4-W/BRR4-BR/W

JACK TYPEDATA 1DATA 2VOICE 1VOICE 2

JACK COLORBLUEN/AIVORYIVORY

CABLECAT 6/BLUECAT 6/BLUE/WHITECAT 6A/GRAYCAT 6A/GRAY

RJ-45(T568A)

PR3 PR4

PR2

PR1

DRAWINGSYMBOL

XXXX-XX

XXXX-XX

2V,2D

1. ALL TELECOM CONDUIT STUBS SHALL BE A MINIMUM 1"EMT. ALL WALL OUTLETBOXES FOR TELECOM TERMINATIONS SHALL BE DUAL-GANG DEEP BOXES.

2. ALL HORIZONTAL CABLING SHALL BE CATAGORY 6 PLENUM RATED REGARDLESS OFINSTALLATION ENVIRONMENT.

3. CONTRACTOR TO FIELD VERIFY INSTALLATION. CONTRACTOR SHALL MAKE EVERYEFFORT TO PERFORM INSTALLATION FOLLOWING LATEST GUIDELINES OF TIA-568/569/607

4. CONTRACTOR TO FOLLOW MANUFACTURER'S RECOMMENDED INSTALLATIONMETHODS/PRACTICES FOR CAT 6.

5. ALL CABLING SHALL BE INSTALLED USING CABLE TRAY IN GENERAL PATHWAYS.

6. A TYPICAL STATION RUN WILL CONSIST OF TWO SHEATHS OF CATEGORY 6 CABLEFROM MDF/IDF TO A COMMUNICATIONS OUTLET. AS REQUIRED A SINGLE RUN OF CAT6 WILL BE USED FOR A WALL TELEPHONE OR SINGLE DATA LOCATION, OBSERVINGTHE CORRECT COLOR CABLE AS LISTED.

7. ALL VOICE CABLING SHALL BE COMMSCOPE CAT 6, 4-PAIR UTP, 1071 FOR PVC AND2071 FOR PLENUM. THE COLOR OF THE VOICE CABLING SHALL BE IVORY, WHERE ASECOND WIRE FOR VOICE IS PRESENT SHALL BE IVORY WITH CONTRASTINGCOLORED STRIP.

8. ALL DATA CABLING SHALL BE COMMSCOPE CAT 6, 4-PAIR UTP, 1071 FOR PVC AND2071 FOR PLENUM. THE COLOR OF THE DATA CABLING SHALL BE BLUE, WHERE ASECOND WIRE FOR DATA IS PRESENT SHALL BE IVORY WITH CONTRASTINGCOLORED STRIP.

9. ALL HVAC CABLING SHALL BE COMMSCOPE CAT 6, 4-PAIR UTP, 1071 FOR PVC AND2071 FOR PLENUM. THE COLOR OF THE DATA CABLING SHALL BE PURPLE, WHERE ASECOND WIRE FOR DATA IS PRESENT SHALL BE PURPLE WITH CONTRASTINGCOLORED STRIP.

10. ALL CABLE TV WILL BE COAX RG-6, 75 OHM COMMSCOPE 2277 (PLENUM) OR 5700(NON-PLENUM) OR APPROVED EQUAL.

11. COORDINATE WITH SPECIFICATION AND INTERIOR FINISH PLANS FOR FACEPLATECOLORS.

12. ALL CAT-6 CABLES SHALL BE TERMINATED, LABELED AND TESTED

FACEPLATE GENERAL NOTES

PROJECT

CLIENT

REGISTRATION

LAKE COUNTY18 N. COUNTY STREETWAUKEGAN, ILLINOIS847.377.2929 tel 847.984.5889 fax

STRUCTURALAECOM999 TOWN AND COUNTRY ROADORANGE, CA 92868312.373.7700 tel 312.938.1109 faxwww.aecom.com

MEP/FPSYSKA HENNESSY GROUP, INC.330 N. WABASH AVE.CHICAGO, IL. 60611 SUITE 1505312.588.3561 tel 312.588.3579 faxwww.syska.com

CODE/LIFE SAFETYROLF JENSEN & ASSOCIATED, INC.600 WEST FULTON STREETCHICAGO, IL. 60661312.879.7200 tel 312.879.7200 faxwww.rjainc.com

ISSUE/REVISION

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

Last

Plo

tted:

File

nam

e:

Printed on ___% Post-ConsumerRecycled Content Paper

ARC

H E

1 30

" x 4

2"Pr

ojec

t Man

agem

ent I

nitia

ls:

Che

cked

:Ap

prov

ed:

123456

A

B

C

D

E

6 5 4 3 2 1

CONSULTANTS

ARCHITECT

AECOM303 EAST WACKER DRIVE,CHICAGO, IL 60601312.373.7700 tel 312.938.1109 faxwww.aecom.com

CIVILCHRISTOPHER B. BURKE, LTD.9575 W. HIGGINS ROADROSEMONT, IL. 60018 SUITE 600847.823.0500 tel 847.823.0520 fax

LANDSCAPEAECOM303 EAST WACKER DRIVE,CHICAGO, IL. 60601 SUITE 600312.373.7792 telwww.aecom.com

DATA TELCOM / AUDIO VISUALAECOM800 LASALLE AVEMINNEAPOLIS, MN 55402 SUITE 400612.376.2169 telwww.aecom.com

ELECTRONIC SECURITYAECOM2950 PROFESSIONAL PLACECOLORADO SPRINGS, CO 80904 SUITE 201719.386.8309 tel 719.386.8339 faxwww.aecom.com

FOOD SERVICES1 FOOD SERVICE231 HOMEWOOD DRIVEBOLINGBROOK, IL 60440630.783.9232 telhttp://s1foodservice.com/

9/22

/201

5 12

:28:

58 P

MC

:\Use

rs\c

anci

oa\D

ocum

ents

\LC

CH

_TO

WER

_T12

_CEN

TRAL

_can

cioa

.rvt

LAKE COUNTYCOURTHOUSEEXPANSION

WAUKEGAN, ILLINOIS 60085301 WASHINGTON STREET

TELECOM DETAILS

2.T502

60288271

N OLE

KE

SCALE: N.T.S.2.T502

1 FP CEILING DATA LOCATION (1D)SCALE: N.T.S.2.T502

4 FP DATA FOR CEILING AP (WIFI)SCALE: N.T.S.2.T502

2FP GROMMETED PASS-THRULOCATION

SCALE: N.T.S.2.T502

5 FP PROJECTOR LOCATION (1D)SCALE: N.T.S.2.T502

3 FP TV LOCATION (IPTV)

SCALE: N.T.S.2.T502

9FP WALL DATA AND CLOCKLOCATION (1D)

SCALE: N.T.S.2.T502

10 FP WALL VOICE LOCATION (1V)SCALE: N.T.S.2.T502

6FP WALL VOICE/DATA LOCATION(1V,1D)

SCALE: N.T.S.2.T502

7FP WALL VOICE/DATA LOCATION(1V,2D)

SCALE: N.T.S.2.T502

8FP WALL VOICE/DATA LOCATION(2V,2D)

I/R DATE DESCRIPTION

2013.12.20 50% CCT GMP PACKAGE2014.02.12 50% TOWER GMP2014.03.31 TOWER BID SET2014.11.03 CONSOLIDATED GMP FINAL2015.09.22 ISSUE FOR CONSTRUCTION2015.10.16 FINAL ISSUED FOR CONSTRUCTION

SERVICES OF ILLINOIS, INC.

Page 10: GENERAL TELECOM NOTES

TYPICALLADDERRACK.

STANDOFF WALLBRACKET

END SUPPORT

CLAMP

ASSEMBELEDEND SUPPORT

NOTESA.COORDINATE WITH PLANS AND SPECIFICATIONS, WHERE RE-ENTERABLE PATHWAY SYSTEM IS USED SHALL UTILIZE SIMILAR FIREAND SMOKE BARRIER SYSTEMS.

4" RISER MECHANICAL RE-ENTERABLE FIRESTOPUNLESS OTHERWISE NOTED

TYPICAL LADDERTYPE CABLETRAY

TYPICAL 2-POSTTR EQUIPMENTRACK

WHERE INDICATED ON PLANS THATRACK IS DIRECTLY FASTEND TO TOP

OF RACK EITHER 2-POST ORCABINET RACKS COORDINATEINSTALLATION METHODE WITH

LADDER RACK MANUFACTUER ANDEQUIPMENT RACK/CABINET

MANUFACTURER. INSTALLATIONSHALL NOT VOID ANY WARRANTIES

OR LISTINGS OF SUPPLIEDEQUIPMENT AND PATHWAYS.

PROPERLY SEAL PENETRATIONSUSING APPROVED METHODSTO MAINTAIN THE FIRE/SMOKERATING OF THE FLOOR. SEESPECIFICATIONS FOR APPROVEDMANUFACTURERS AND MATERIAL.

PROVIDE MECHANICAL RE-ENTERABLE FIRESTOP UNLESSNOTED OTHERWISE.

(4") INTERMEDIATEMETAL CONDUIT,UNLESS OTHERWISE(TYPICAL) FINISH FLOOR

NOTESA.COORDINATE WITH PLANS AND SPECIFICATIONS, WHERE RE-ENTERABLEPATHWAY SYSTEM IS USED SHALL UTILIZE SIMILAR FIRE AND SMOKEBARRIER SYSTEMS.

PROJECT

CLIENT

REGISTRATION

LAKE COUNTY18 N. COUNTY STREETWAUKEGAN, ILLINOIS847.377.2929 tel 847.984.5889 fax

STRUCTURALAECOM999 TOWN AND COUNTRY ROADORANGE, CA 92868312.373.7700 tel 312.938.1109 faxwww.aecom.com

MEP/FPSYSKA HENNESSY GROUP, INC.330 N. WABASH AVE.CHICAGO, IL. 60611 SUITE 1505312.588.3561 tel 312.588.3579 faxwww.syska.com

CODE/LIFE SAFETYROLF JENSEN & ASSOCIATED, INC.600 WEST FULTON STREETCHICAGO, IL. 60661312.879.7200 tel 312.879.7200 faxwww.rjainc.com

ISSUE/REVISION

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

Last

Plo

tted:

File

nam

e:

Printed on ___% Post-ConsumerRecycled Content Paper

ARC

H E

1 30

" x 4

2"Pr

ojec

t Man

agem

ent I

nitia

ls:

Che

cked

:Ap

prov

ed:

123456

A

B

C

D

E

6 5 4 3 2 1

CONSULTANTS

ARCHITECT

AECOM303 EAST WACKER DRIVE,CHICAGO, IL 60601312.373.7700 tel 312.938.1109 faxwww.aecom.com

CIVILCHRISTOPHER B. BURKE, LTD.9575 W. HIGGINS ROADROSEMONT, IL. 60018 SUITE 600847.823.0500 tel 847.823.0520 fax

LANDSCAPEAECOM303 EAST WACKER DRIVE,CHICAGO, IL. 60601 SUITE 600312.373.7792 telwww.aecom.com

DATA TELCOM / AUDIO VISUALAECOM800 LASALLE AVEMINNEAPOLIS, MN 55402 SUITE 400612.376.2169 telwww.aecom.com

ELECTRONIC SECURITYAECOM2950 PROFESSIONAL PLACECOLORADO SPRINGS, CO 80904 SUITE 201719.386.8309 tel 719.386.8339 faxwww.aecom.com

FOOD SERVICES1 FOOD SERVICE231 HOMEWOOD DRIVEBOLINGBROOK, IL 60440630.783.9232 telhttp://s1foodservice.com/

9/22

/201

5 12

:29:

15 P

MC

:\Use

rs\c

anci

oa\D

ocum

ents

\LC

CH

_TO

WER

_T12

_CEN

TRAL

_can

cioa

.rvt

LAKE COUNTYCOURTHOUSEEXPANSION

WAUKEGAN, ILLINOIS 60085301 WASHINGTON STREET

TELECOM DETAILS

2.T503

60288271

Che

cker

SCALE: N.T.S.2.T503

1

TYPICAL LADDER RACKINSTALLATION AND HARDWAREDETAIL

SCALE: N.T.S.2.T503

2LADDER RACK WITHCROSSOVER DETAIL

SCALE: N.T.S.2.T503

3LADDER RACK SUPPORTED BYTR RACK CABINET DETAIL

SCALE: N.T.S.2.T503

4CONDUIT RISER FLOORPENETRATION DETAIL

I/R DATE DESCRIPTION

2013.12.20 50% CCT GMP PACKAGE2014.02.12 50% TOWER GMP2014.03.31 TOWER BID SET2014.11.03 CONSOLIDATED GMP FINAL2015.09.22 ISSUE FOR CONSTRUCTION2015.10.16 FINAL ISSUED FOR CONSTRUCTION

SERVICES OF ILLINOIS, INC.

Page 11: GENERAL TELECOM NOTES

GROUND BUSBAR (TGB OR TMGB)SEE PLANS AND SPECIFICATIONSFOR SIZES.

#6AWG GROUNDING RACK BONDINGJUMPER. CONDUCTOR SHALL BEINSULATED AND GREEN IN COLORAND INSTALLED PERMANUFACTURER'S INSTALLATIONINSTRUCTIONS . COORDINATEINSTALLATION WITH ELECTRICALCONTRACTOR, SEE SPECIFICATIONFOR ADDITIONAL INFORMATION.

#6AWG GROUNDING HORIZONTALCONDUCTOR. CONDUCTOR SHALL BEINSULATED AND GREEN IN COLOR,CONDUCTOR TO BE INSTALLED BETWEENTGB OR TMGB (WHICH EVER IS PRESENT)AND ELECTRICALLY CONDUCTIVEPATHWAY ABOVE. COORDINATEINSTALLATION WITH ELECTRICALCONTRACTOR, SEE SPECIFICATION FORADDITIONAL INFORMATION.

#6AWG GROUNDINGRACK BONDINGJUMPER.

NOTE:1. DETAIL IS FOR REFERENCE AND SHOWN FOR DESIGNINTENT ONLY. COORDINATE ALL GROUNDING REQUIREMENTSWITH EIA/TIA STANDARDS, ELECTRICAL CONTRACTOR ANDALL NECESSARY BUILDING CODES AND THE MOST CURRENTLYADOPTED VERSION OF NFPA 70 (NATIONAL ELECTRICAL CODE[NEC]) AND ALL NECESSARY LOCAL JURISDICTIONAMENDMENTS.

2. GROUNDING SYSTEM SHOWN FOR REFERENCE ONLY,PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR.LOW VOLTAGE/SYSTEMS CONTRACTOR TO PROVIDEGROUNDING FROM TR/IDF/MDF EQUIPMENT TO NEARESTGROUNDING BUSBAR (TGB OR TMGB). COORDINATE WITH E.C.

GROUND BAR

NUT

SLOTTEDLOCKWASHER

INSULATOR

FLAT WASHER

BOLT HEAD

BRACKET

12"

4"2"

1" 1"

COORDINATE GROUNDINGBACKBONE CONDUCTORWITH ELECTRICALCONTRACTOR

NOTE:1. DETAIL IS FOR REFERENCE AND SHOWN FOR DESIGNINTENT ONLY. CONTRACTOR SHALL COORDINATE ALLGROUNDING REQUIREMENTS WITH EIA/TIA STANDARDS,ELECTRICAL CONTRACTOR AND ALL NECESSARY BUILDINGCODES AND THE MOST CURRENTLY ADOPTED VERSION OFNFPA 70 (NATIONAL ELECTRICAL CODE [NEC]) AND ALLNECESSARY JURISDICTION ADOPTIONS.

2. GROUNDING SYSTEM SHOWN FOR REFERENCE ONLY,PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR.LOW VOLTAGE/SYSTEMS CONTRACTOR TO PROVIDEGROUNDING FROM TR/IDF/MDF EQUIPMENT TO NEARESTGROUNDING BUSBAR (TGB OR TMGB). COORDINATE WITH E.C.

COPPER COATEDTINNED BAR

4"

16"

GROUND BAR

NUT

SLOTTEDLOCKWASHER

INSULATORFLAT WASHER

BOLT HEAD

BRACKET

COPPER COATEDTINNED BAR

2"

1"

1"

COORDINATE GROUNDINGBACKBONE CONDUCTORWITH ELECTRICALCONTRACTOR

NOTE:1. DETAIL IS FOR REFERENCE AND SHOWN FOR DESIGNINTENT ONLY. CONTRACTOR SHALL COORDINATE ALLGROUNDING REQUIREMENTS WITH EIA/TIA STANDARDS,ELECTRICAL CONTRACTOR AND ALL NECESSARY BUILDINGCODES AND THE MOST CURRENTLY ADOPTED VERSION OFNFPA 70 (NATIONAL ELECTRICAL CODE [NEC]) AND ALLNECESSARY JURISDICTION ADOPTIONS.

2. GROUNDING SYSTEM SHOWN FOR REFERENCE ONLY,PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR.LOW VOLTAGE/SYSTEMS CONTRACTOR TO PROVIDEGROUNDING FROM TR/IDF/MDF EQUIPMENT TO NEARESTGROUNDING BUSBAR (TGB OR TMGB). COORDINATE WITH E.C.

4"

24"

1"

1"

2"

2"

GROUND BAR

NUT

SLOTTEDLOCKWASHER

INSULATOR

FLAT WASHER

BOLT HEAD

BRACKET

COPPER COATEDTINNED BAR

COORDINATE GROUNDINGBACKBONE CONDUCTORWITH ELECTRICALCONTRACTOR

NOTE:1. DETAIL IS FOR REFERENCE AND SHOWN FOR DESIGNINTENT ONLY. CONTRACTOR SHALL COORDINATE ALLGROUNDING REQUIREMENTS WITH EIA/TIA STANDARDS,ELECTRICAL CONTRACTOR AND ALL NECESSARY BUILDINGCODES AND THE MOST CURRENTLY ADOPTED VERSION OFNFPA 70 (NATIONAL ELECTRICAL CODE [NEC]) AND ALLNECESSARY JURISDICTION ADOPTIONS.

2. GROUNDING SYSTEM SHOWN FOR REFERENCE ONLY,PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR.LOW VOLTAGE/SYSTEMS CONTRACTOR TO PROVIDEGROUNDING FROM TR/IDF/MDF EQUIPMENT TO NEARESTGROUNDING BUSBAR (TGB OR TMGB). COORDINATE WITH E.C.

CABLE TRAYTYPICAL BUTTSPLICE

#6AWG BONDING JUMPER TO BRIDGECABLE TRAY/LADDER RACKJUNCTIONS CABLE TRAY/LADDER

RACK SECTION

NOTE:1. DETAIL IS FOR REFERENCE AND SHOWN FOR DESIGNINTENT ONLY. CONTRACTOR SHALL COORDINATE ALLGROUNDING REQUIREMENTS WITH EIA/TIA STANDARDS,ELECTRICAL CONTRACTOR AND ALL NECESSARY BUILDINGCODES AND THE MOST CURRENTLY ADOPTED VERSION OFNFPA 70 (NATIONAL ELECTRICAL CODE [NEC]) AND ALLNECESSARY JURISDICTION ADOPTIONS.

2. GROUNDING SYSTEM SHOWN FOR REFERENCE ONLY,PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR.LOW VOLTAGE/SYSTEMS CONTRACTOR TO PROVIDEGROUNDING FROM TR/IDF/MDF EQUIPMENT TO NEARESTGROUNDING BUSBAR (TGB OR TMGB). COORDINATE WITH E.C.

GROUND BUSBAR (TGB OR TMGB)SEE PLANS AND SPECIFICATIONSFOR SIZES.

GROUNDING BACKBONECONDUCTOR. COORDINATEINSTALLATION WITH ELECTRICALCONTRACTOR, SEE GROUNDINGRISER DIAGRAM FOR EXACTSIZE.

GROUNDING BUSBAR BONDEDTO BUILDING STRUCTURALSTEEL, COORDINATE WITHELECTRICAL CONTRACTOR FORINSTALLATION ANDTERMINATION, SEE GROUNDINGRISER DIAGRAM FOR EXACT SIZE

NOTE:1. DETAIL IS FOR REFERENCE AND SHOWN FOR DESIGNINTENT ONLY. CONTRACTOR SHALL COORDINATE ALLGROUNDING REQUIREMENTS WITH EIA/TIA STANDARDS,ELECTRICAL CONTRACTOR AND ALL NECESSARY BUILDINGCODES AND THE MOST CURRENTLY ADOPTED VERSION OFNFPA 70 (NATIONAL ELECTRICAL CODE [NEC]) AND ALLNECESSARY JURISDICTION ADOPTIONS.

2. GROUNDING SYSTEM SHOWN FOR REFERENCE ONLY,PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR.LOW VOLTAGE/SYSTEMS CONTRACTOR TO PROVIDEGROUNDING FROM TR/IDF/MDF EQUIPMENT TO NEARESTGROUNDING BUSBAR (TGB OR TMGB). COORDINATE WITH E.C.

PROJECT

CLIENT

REGISTRATION

LAKE COUNTY18 N. COUNTY STREETWAUKEGAN, ILLINOIS847.377.2929 tel 847.984.5889 fax

STRUCTURALAECOM999 TOWN AND COUNTRY ROADORANGE, CA 92868312.373.7700 tel 312.938.1109 faxwww.aecom.com

MEP/FPSYSKA HENNESSY GROUP, INC.330 N. WABASH AVE.CHICAGO, IL. 60611 SUITE 1505312.588.3561 tel 312.588.3579 faxwww.syska.com

CODE/LIFE SAFETYROLF JENSEN & ASSOCIATED, INC.600 WEST FULTON STREETCHICAGO, IL. 60661312.879.7200 tel 312.879.7200 faxwww.rjainc.com

ISSUE/REVISION

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

Last

Plo

tted:

File

nam

e:

Printed on ___% Post-ConsumerRecycled Content Paper

ARC

H E

1 30

" x 4

2"Pr

ojec

t Man

agem

ent I

nitia

ls:

Che

cked

:Ap

prov

ed:

123456

A

B

C

D

E

6 5 4 3 2 1

CONSULTANTS

ARCHITECT

AECOM303 EAST WACKER DRIVE,CHICAGO, IL 60601312.373.7700 tel 312.938.1109 faxwww.aecom.com

CIVILCHRISTOPHER B. BURKE, LTD.9575 W. HIGGINS ROADROSEMONT, IL. 60018 SUITE 600847.823.0500 tel 847.823.0520 fax

LANDSCAPEAECOM303 EAST WACKER DRIVE,CHICAGO, IL. 60601 SUITE 600312.373.7792 telwww.aecom.com

DATA TELCOM / AUDIO VISUALAECOM800 LASALLE AVEMINNEAPOLIS, MN 55402 SUITE 400612.376.2169 telwww.aecom.com

ELECTRONIC SECURITYAECOM2950 PROFESSIONAL PLACECOLORADO SPRINGS, CO 80904 SUITE 201719.386.8309 tel 719.386.8339 faxwww.aecom.com

FOOD SERVICES1 FOOD SERVICE231 HOMEWOOD DRIVEBOLINGBROOK, IL 60440630.783.9232 telhttp://s1foodservice.com/

9/22

/201

5 12

:29:

27 P

MC

:\Use

rs\c

anci

oa\D

ocum

ents

\LC

CH

_TO

WER

_T12

_CEN

TRAL

_can

cioa

.rvt

LAKE COUNTYCOURTHOUSEEXPANSION

WAUKEGAN, ILLINOIS 60085301 WASHINGTON STREET

TELECOM DETAILS

2.T504

60288271

Che

cker

SCALE: N.T.S.2.T504

1TYPICAL TR/MDF/IDFGROUNDING DETAIL

SCALE: N.T.S.2.T504

212" TELECOM GROUND BAR (FORTR'S WITH 1 RACK/CABINET)

SCALE: N.T.S.2.T504

3

16" TELECOM GROUND BAR(FOR TR'S WITH 2 OR MORERACK/CABS)

SCALE: N.T.S.2.T504

424" TELECOM MAIN GROUND BAR(TMGB)

SCALE: N.T.S.2.T504

5CABLE TRAY/LADDER RACKBONDING DETAIL

SCALE: N.T.S.2.T504

6 GROUND BAR MOUNTING DETAILI/R DATE DESCRIPTION

2013.12.20 50% CCT GMP PACKAGE2014.02.12 50% TOWER GMP2014.03.31 TOWER BID SET2014.11.03 CONSOLIDATED GMP FINAL2015.09.22 ISSUE FOR CONSTRUCTION2015.10.16 FINAL ISSUED FOR CONSTRUCTION

SERVICES OF ILLINOIS, INC.

Page 12: GENERAL TELECOM NOTES

FACEPLATE LABELPLACEMENT

MODULAR FURNITURE 4-PORT FACEPLATE, CAT-6NON-KEYED, 4-PAIR, RJ-45JACK

CAT 6 CABLE TO TR(TYPICAL)

REMOVE KNOCKOUTFROM PARTITIONRACEWAY (TYPIAL)

NOTE: MODULAR FURNITURE PLATE/JACKS TO BE OF SAME MANUFACTURERAS CAT 6 CONNECTIVITY HARDWARE OR CABLE. JACKS ANDCONNECTIVITY HARDWARE BY SYSTEM FURNITURE MANUFACTURER

IN PAIRS.

CABLE CLAMPFOR CABLE SLACK, USE

CABLES TO OTHER STATIONS

(4) PAIR CAT-6 CABLE

SNAP-IN FACEPLATESEE DETAIL ABOVE

(TYP)

FURNITURE FOR TELECOMMUNICATION CABLESCHANNEL FURNISHED WITH SYSTEM

6" X 3" CHANNEL

FURNITURESYSTEM

CABLE PASS-THRU

FEED THRU FACEPLATEWITH OPENING FOR

ARE NOT ACCEPTABLE FOR USE.

CAT-6 PATCH CABLE

GENERAL DETAIL NOTES:

1. ALL TELECOM CONDUIT STUBS WILL BE MINIMUM 1" EMT. ALL WALL OUTLETBOXES FOR TELECOM TERMINATIONS WILL BE DUAL GANG DEEP BOXES.

2. ALL HORIZONTAL CABLING WILL BE CATEGORY 6 PLENUM RATEDREGARDLESS OF INSTALLATION ENVIRONMENT.

3. CONTRACTOR TO FIELD VERIFY INSTALLATION CONDITIONS PRIOR TOINSTALLATION. CONTRACTOR SHALL MAKE EVERY EFFORT TO PERFORMINSTALLATION FOLLOWING LATEST GUIDELINES OF TIA-568, -569, AND -607.

4. CONTRACTOR TO FOLLOW MANUFACTURER'S RECOMMENDED INSTALLATIONMETHODS/PRACTICES FOR CAT 6.

5. ALL CABLING SHALL BE INSTALLED USING HANGERS AND J-HOOKS (NOCABLETRAY IN GENERAL PATHWAYS).

6. CATEGORY 6 RJ-45 JACKS WILL BE BLUE FOR VOIP AND ORANGE FORDATA AND WIRELESS.

7. CATEGORY 6 CABLE WILL BE YELLOW FOR VOIP, GRAY FOR DATA ANDORANGE FOR WIRELESS.

8. FACEPLATES WILL BE IVORY.9. ALL CATEGORY 6 CABLES WILL BE TERMINATED AND TESTED.

CABLE BUNDLE ROUTED FROM FEED THRU FACEPLATE ONWALL OR FLOORBOX TO THE FURNITURE. KEEP CABLINGHIDDEN FROM VIEW. PROVIDE 2" (MIN) FLEXIBLE METALCONDUIT AROUND CABLE BUNDLE IF THE DISTANCEBETWEEN FEED THRU FACEPLATES IS GREATER THAN 4".COORDINATE WITH FURNITURE INSTALLER.

CABLE PASS-THRU

FEED THRU FACEPLATEWITH OPENING FOR

WALL

PROJECT

CLIENT

REGISTRATION

LAKE COUNTY18 N. COUNTY STREETWAUKEGAN, ILLINOIS847.377.2929 tel 847.984.5889 fax

STRUCTURALAECOM999 TOWN AND COUNTRY ROADORANGE, CA 92868312.373.7700 tel 312.938.1109 faxwww.aecom.com

MEP/FPSYSKA HENNESSY GROUP, INC.330 N. WABASH AVE.CHICAGO, IL. 60611 SUITE 1505312.588.3561 tel 312.588.3579 faxwww.syska.com

CODE/LIFE SAFETYROLF JENSEN & ASSOCIATED, INC.600 WEST FULTON STREETCHICAGO, IL. 60661312.879.7200 tel 312.879.7200 faxwww.rjainc.com

ISSUE/REVISION

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

Last

Plo

tted:

File

nam

e:

Printed on ___% Post-ConsumerRecycled Content Paper

ARC

H E

1 30

" x 4

2"Pr

ojec

t Man

agem

ent I

nitia

ls:

Che

cked

:Ap

prov

ed:

123456

A

B

C

D

E

6 5 4 3 2 1

CONSULTANTS

ARCHITECT

AECOM303 EAST WACKER DRIVE,CHICAGO, IL 60601312.373.7700 tel 312.938.1109 faxwww.aecom.com

CIVILCHRISTOPHER B. BURKE, LTD.9575 W. HIGGINS ROADROSEMONT, IL. 60018 SUITE 600847.823.0500 tel 847.823.0520 fax

LANDSCAPEAECOM303 EAST WACKER DRIVE,CHICAGO, IL. 60601 SUITE 600312.373.7792 telwww.aecom.com

DATA TELCOM / AUDIO VISUALAECOM800 LASALLE AVEMINNEAPOLIS, MN 55402 SUITE 400612.376.2169 telwww.aecom.com

ELECTRONIC SECURITYAECOM2950 PROFESSIONAL PLACECOLORADO SPRINGS, CO 80904 SUITE 201719.386.8309 tel 719.386.8339 faxwww.aecom.com

FOOD SERVICES1 FOOD SERVICE231 HOMEWOOD DRIVEBOLINGBROOK, IL 60440630.783.9232 telhttp://s1foodservice.com/

9/22

/201

5 12

:29:

41 P

MC

:\Use

rs\c

anci

oa\D

ocum

ents

\LC

CH

_TO

WER

_T12

_CEN

TRAL

_can

cioa

.rvt

LAKE COUNTYCOURTHOUSEEXPANSION

WAUKEGAN, ILLINOIS 60085301 WASHINGTON STREET

TELECOM DETAILS

2.T505

60288271

Che

cker

SCALE: N.T.S.2.T505

1WORKSTATION CABLEINSTALLATION DETAILS

I/R DATE DESCRIPTION

2013.12.20 50% CCT GMP PACKAGE2014.02.12 50% TOWER GMP2014.03.31 TOWER BID SET2014.11.03 CONSOLIDATED GMP FINAL2015.09.22 ISSUE FOR CONSTRUCTION2015.10.16 FINAL ISSUED FOR CONSTRUCTION

SERVICES OF ILLINOIS, INC.

Page 13: GENERAL TELECOM NOTES

120VAC 120VAC

AUDIO INCOMPUTER IN

NOTE:A. TABLE TOP MEDIA INTERFACE SHALL BE PROVIDED BY AVCONTRACTOR, INSTALLED BY MILLWORK SUPPLIER WITH FINAL DATACABLE TERMINATIONS BY TELECOM CONTRACTOR. PROVIDEINSTALLED WITHIN MILLWORK CUBBY. COORDINATE REQUIREMENTSWITH MILLWORK SUPPLIER.B. ALL RJ-45 OUTLETS ARE UTP OUTLETS UNLESS NOTED OTHERWISE.

PROVIDE DATACABLING

TO DATA RACK

120VACELECTRICAL BY

OTHERS

A/VCABLINGTO A/V

RACK (SEETA SERIES

DWGS)

FLOORBOX/POKE-THRU BY E.C.. PROVIDECONNECTIONS FROM FLOORBOX TO TABLE BOXES.CONCEAL ALL CABLING WITHIN PORTABLEATTORNEY'S TABLE.

HDBASE-TVIDEO

HDBASE-TVIDEO

IP AUDIO

IP AUDIO

DATA

DATA

DATA

DATA

SHIELDED CAT6 OUTLET

POE AVB AUDIOCONVERTER. SEETA SERIES DWGS.

120VAC 120VAC120VAC 120VAC

PROVIDE DATACABLING

TO DATA RACK

120VACELECTRICAL BY

OTHERS

A/VCABLINGTO A/V

RACK (SEETA SERIES

DWGS)

FLOORBOX/POKE-THRU BY E.C.. PROVIDE CONNECTIONSFROM FLOORBOX TO EVIDENCE PRESENTATION CARTINTERFACE ON THE SIDE OF THE TABLE. CONCEAL ALLCABLING WITHIN PORTABLE ATTORNEY'S TABLE.

NOTES:A. MOBILE CART INTERFACE PROVIDED BY DATA CONTRACTOR,INSTALLED WITHIN MILLWORK CUBBY. COORDINATE REQUIREMENTSWITH MILLWORK SUPPLIER. EVIDENCE PRESENTATION CART SHALLCONNECT TO INTERFACE USING ONLY CATEGORY 6 AND SHIELDEDCATEGORY 6 PATCH CORDS.B. ALL OUTLETS ARE UTP OUTLETS UNLESS NOTED OTHERWISE.

PROVIDE PATCH CORDS FROM INTERFACE TOEVIDENCE PRESENTATION CART FOR EACH OUTLET.

HDBASE-TVIDEO

HDBASE-TVIDEO

IP AUDIO

IP AUDIO

DATA

DATA

DATA

DATA

SHIELDED CAT6 OUTLET

SHIELDED CAT6 OUTLET

POWER OUTLET BY E.C.

120VACELECTRICAL BY

OTHERS

PROJECT

CLIENT

REGISTRATION

LAKE COUNTY18 N. COUNTY STREETWAUKEGAN, ILLINOIS847.377.2929 tel 847.984.5889 fax

STRUCTURALAECOM999 TOWN AND COUNTRY ROADORANGE, CA 92868312.373.7700 tel 312.938.1109 faxwww.aecom.com

MEP/FPSYSKA HENNESSY GROUP, INC.330 N. WABASH AVE.CHICAGO, IL. 60611 SUITE 1505312.588.3561 tel 312.588.3579 faxwww.syska.com

CODE/LIFE SAFETYROLF JENSEN & ASSOCIATED, INC.600 WEST FULTON STREETCHICAGO, IL. 60661312.879.7200 tel 312.879.7200 faxwww.rjainc.com

ISSUE/REVISION

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

Last

Plo

tted:

File

nam

e:

Printed on ___% Post-ConsumerRecycled Content Paper

ARC

H E

1 30

" x 4

2"Pr

ojec

t Man

agem

ent I

nitia

ls:

Che

cked

:Ap

prov

ed:

123456

A

B

C

D

E

6 5 4 3 2 1

CONSULTANTS

ARCHITECT

AECOM303 EAST WACKER DRIVE,CHICAGO, IL 60601312.373.7700 tel 312.938.1109 faxwww.aecom.com

CIVILCHRISTOPHER B. BURKE, LTD.9575 W. HIGGINS ROADROSEMONT, IL. 60018 SUITE 600847.823.0500 tel 847.823.0520 fax

LANDSCAPEAECOM303 EAST WACKER DRIVE,CHICAGO, IL. 60601 SUITE 600312.373.7792 telwww.aecom.com

DATA TELCOM / AUDIO VISUALAECOM800 LASALLE AVEMINNEAPOLIS, MN 55402 SUITE 400612.376.2169 telwww.aecom.com

ELECTRONIC SECURITYAECOM2950 PROFESSIONAL PLACECOLORADO SPRINGS, CO 80904 SUITE 201719.386.8309 tel 719.386.8339 faxwww.aecom.com

FOOD SERVICES1 FOOD SERVICE231 HOMEWOOD DRIVEBOLINGBROOK, IL 60440630.783.9232 telhttp://s1foodservice.com/

9/22

/201

5 12

:29:

52 P

MC

:\Use

rs\c

anci

oa\D

ocum

ents

\LC

CH

_TO

WER

_T12

_CEN

TRAL

_can

cioa

.rvt

LAKE COUNTYCOURTHOUSEEXPANSION

WAUKEGAN, ILLINOIS 60085301 WASHINGTON STREET

TELECOM DETAILS

2.T506

60288271

Che

cker

SCALE: 12" = 1'-0"2.T506

1COURT ROOM TABLE TOP MEDIAINTERFACE

SCALE: 12" = 1'-0"2.T506

2EVIDENCE PRESENTATION CARTINTERFACE

I/R DATE DESCRIPTION

2014.02.12 50% TOWER GMP2014.03.31 TOWER BID SET2014.11.03 CONSOLIDATED GMP FINAL2015.09.22 ISSUE FOR CONSTRUCTION2015.10.16 FINAL ISSUED FOR CONSTRUCTION

SERVICES OF ILLINOIS, INC.

Page 14: GENERAL TELECOM NOTES

B1-P

AR

KIN

G

LE

VE

L-3

LE

VE

L-4

LE

VE

L-5

LE

VE

L-6

LE

VE

L-7

LE

VE

L-8

MD

F B

1008

IDF

-1202

IDF

-2006ID

F-3

312

IDF

-4312

IDF

-5312

IDF

-6312

IDF

-7312

IDF

-8312

CE

ILI N

G

CE

ILI N

G

CE

ILI N

G

CE

ILI N

G

CE

ILI N

G

CE

ILI N

G

(2)

4"C

SP

AR

E

(2)

4"C

SP

AR

E

(2)

4"C

SP

AR

E

(2)

4"C

SP

AR

E

(2)

4"C

SP

AR

E

(2)

4"C

SP

AR

E

(2)

4"C

SP

AR

E

(2)

4"C

SP

AR

E

(2)

4"C

LV

L-8

(2)

4"C

LV

L-7

(2)

4"C

LV

L-6

(2)

4"C

LV

L-5

(2)

4"C

LV

L-4

(2)

4"C

LV

L-3

(2)

4"C

LV

L-2

(2)

4"C

LV

L-1

(2)

4"C

LV

L-8

(2)

4"C

LV

L-7

(2)

4"C

LV

L-6

(2)

4"C

LV

L-5

(2)

4"C

LV

L-4

(2)

4"C

LV

L-3

(2)

4"C

LV

L-2

(2)

4"C

LV

L-8

(2)

4"C

LV

L-7

(2)

4"C

LV

L-6

(2)

4"C

LV

L-5

(2)

4"C

LV

L-4

(2)

4"C

LV

L-3

(2)

4"C

LV

L-8

(2)

4"C

LV

L-7

(2)

4"C

LV

L-6

(2)

4"C

LV

L-5

(2)

4"C

LV

L-4

(2)

4"C

LV

L-8

(2)

4"C

LV

L-7

(2)

4"C

LV

L-6

(2)

4"C

LV

L-5

(2)

4"C

LV

L-8

(2)

4"C

LV

L-7

(2)

4"C

LV

L-6

(2)

4"C

LV

L-8

(2)

4"C

LV

L-7

(2)

4"C

LV

L-8

LE

VE

L-1

LE

VE

L-2

CE

ILI N

G

CE

ILI N

G

ME

CH

PE

NT

HO

US

E

BA

BC

OX

(E

X)

IDF

1-2

421

IDF

1-1

137

IDF

1-1

138

MD

F (

EX

IST

ING

)

SE

CU

RIT

YE

LE

C. 1-B

125

B1-P

AR

KIN

G

AN

NE

X (

EX

)

LE

VE

L-1

LE

VE

L-2

CE

ILI N

G

CE

ILI N

G

(2)

4"C

SP

AR

E(2

) 4"C

SP

AR

E

(2)

4"C

SP

AR

E

(1)

4"C

(1)

4"C

(1)

4"C

(1)

4"C

MA

ST

ER

CO

NT

RO

L R

M(E

X)

(1)

4"C

(1)

4"C

(1)

4"C

(1)

4"C

(1)

4"C

MD

F (

EX

IST

ING

)

(6)

4"C

TO

MA

NH

OL

E A

T C

OU

NT

Y S

TR

EE

T

(4)

4"C

BR

IDG

E

BR

IDG

EC

EIL

I NG

IDF

(E

XIS

TIN

G)

(5)

3"C

(1)

4"C

(1)

4"C

(1)

4"C

(1)

4"C

(1)

4"C

(4)

4"C

AV

-1314

AV

-2108

IDF

-22

01B

(1)

4"C

(1)

4"C

(2)

4"C

LV

L-2

(2)

4"C

LV

L-2

(1)

4"C

(1)

4"C

(1)

4"C

(1)

4"C

PH

ON

E (

EX

)

(1)

4"C

(E

X).

AV

-8402

(1)

4"C

(1)

4"C

(2)

4"C

PT

H

CC

T T

OW

ER

WE

AT

HE

RH

EA

D F

OR

SA

TE

LLIT

E/A

NT

EN

NA

EC

AB

LIN

G A

T R

OO

F

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

18"

VE

RT

ICA

LL

AD

DE

RR

AC

K

(1)

3"C

(1)

3"C

(1)

3"C

(1)

3"C

(1)

3"C

(1)

4"C

(1)

4"C

(1)

4"C

(1)

4"C

EQ

UIP

ME

NT

SH

OW

N IS

EX

IST

ING

AN

D S

HO

WN

FO

RR

EF

ER

EN

CE

ON

LY

- F

IELD

VE

RIF

Y E

XA

CT

CO

ND

ITIO

NS

.

EQ

UIP

ME

NT

SH

OW

N IS

EX

IST

ING

AN

D S

HO

WN

FO

RR

EF

ER

EN

CE

ON

LY

- F

IELD

VE

RIF

Y E

XA

CT

CO

ND

ITIO

NS

.

EQ

UIP

ME

NT

SH

OW

N IS

EX

IST

ING

AN

D S

HO

WN

FO

RR

EF

ER

EN

CE

ON

LY

- F

IELD

VE

RIF

Y E

XA

CT

CO

ND

ITIO

NS

.

EQ

UIP

ME

NT

SH

OW

N IS

EX

IST

ING

AN

D S

HO

WN

FO

RR

EF

ER

EN

CE

ON

LY

- F

IELD

VE

RIF

Y E

XA

CT

CO

ND

ITIO

NS

.(2

)4

" C

FR

OM

MD

F T

O

SE

CU

RIT

Y R

OO

M

1

PROJECT

CLIENT

REGISTRATION

LAKE COUNTY18 N. COUNTY STREET

WAUKEGAN, ILLINOIS

847.377.2929 tel 847.984.5889 fax

STRUCTURAL

AECOM

999 TOWN AND COUNTRY ROAD

ORANGE, CA 92868

312.373.7700 tel 312.938.1109 fax

www.aecom.com

MEP/FP

SYSKA HENNESSY GROUP, INC.

330 N. WABASH AVE.

CHICAGO, IL. 60611 SUITE 1505

312.588.3561 tel 312.588.3579 fax

www.syska.com

CODE/LIFE SAFETY

ROLF JENSEN & ASSOCIATED, INC.

600 WEST FULTON STREET

CHICAGO, IL. 60661

312.879.7200 tel 312.879.7200 fax

www.rjainc.com

ISSUE/REVISION

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

La

st P

lotted

:F

ilena

me:

Printed on ___% Post-ConsumerRecycled Content Paper

AR

CH

E1 3

0"

x 4

2"

Pro

ject M

ana

ge

me

nt In

itia

ls:

Checked:

App

rove

d:

123456

A

B

C

D

E

6 5 4 3 2 1

CONSULTANTS

ARCHITECT

AECOM303 EAST WACKER DRIVE,

CHICAGO, IL 60601

312.373.7700 tel 312.938.1109 fax

www.aecom.com

CIVIL

CHRISTOPHER B. BURKE, LTD.

9575 W. HIGGINS ROAD

ROSEMONT, IL. 60018 SUITE 600

847.823.0500 tel 847.823.0520 fax

LANDSCAPE

AECOM

303 EAST WACKER DRIVE,

CHICAGO, IL. 60601 SUITE 600

312.373.7792 tel

www.aecom.com

DATA TELCOM / AUDIO VISUAL

AECOM

800 LASALLE AVE

MINNEAPOLIS, MN 55402 SUITE 400

612.376.2169 tel

www.aecom.com

ELECTRONIC SECURITY

AECOM

2950 PROFESSIONAL PLACE

COLORADO SPRINGS, CO 80904 SUITE 201

719.386.8309 tel 719.386.8339 fax

www.aecom.com

FOOD SERVICE

S1 FOOD SERVICE

231 HOMEWOOD DRIVE

BOLINGBROOK, IL 60440

630.783.9232 tel

http://s1foodservice.com/

10

/9/2

01

5 1

:54

:44 P

MC

:\U

sers

\dre

wt1

\Docu

men

ts\L

CC

H_T

OW

ER

_T

12

_C

EN

TR

AL_d

rew

t1.r

vt

LAKE COUNTYCOURTHOUSEEXPANSION

WAUKEGAN, ILLINOIS 60085

301 WASHINGTON STREET

TELECOM PATHWAY RISERDIAGRAM

2.T601

60288271

N OLE

KE

SCALE: 3/16" = 1'-0"

VOICE/DATA PATHWAY RISER DIAGRAM - ROTATED 90 DEGREES

GE

NE

RA

L T

ELE

CO

M P

AT

HW

AY

RIS

ER

NO

TE

S1

TY

PIC

AL E

VE

RY

CO

ND

UIT

PE

NE

TR

AT

ION

/SLE

EV

E S

HO

WN

TH

RO

UG

H A

FLO

OR

SLA

B O

R F

IRE

RA

TE

D W

ALL W

ITH

INT

ELE

CO

M O

R A

V R

OO

MS

SH

ALL B

E A

ME

CH

AN

ICA

L R

E-E

NT

ER

AB

LE

FIR

ES

TO

P 4

" H

ILT

I S

PE

ED

SLE

EV

E O

R E

QU

AL IN

EQ

UA

LQ

UA

NT

ITIE

S (

NO

T C

ON

DU

IT S

LE

EV

E).

2R

EF

ER

TO

ELE

CT

RIC

AL D

WG

S (

E S

ER

IES

) F

OR

AD

DIT

ION

AL T

ELE

CO

M P

AT

HW

AY

RO

UT

ING

IN

FO

RM

AT

ION

.

3P

RO

VID

E F

AB

RIC

-TY

PE

IN

NE

RD

UC

T W

ITH

IN A

LL C

ON

DU

ITS

PR

IOR

TO

CA

BLE

IN

ST

ALLA

TIO

N. P

RO

VID

E A

MIN

IMU

M O

F T

WO

3-C

ELL IN

NE

RD

UC

TS

IN

4"

CO

ND

UIT

S A

ND

ON

E 3

-CE

LL IN

NE

RD

UC

T IN

3"

AN

D 2

" C

ON

DU

ITS

.

4A

LL F

IBE

R O

PT

IC B

AC

KB

ON

E P

AT

HW

AY

S S

HA

LL S

UP

PO

RT

AU

DIO

-VID

EO

, S

EC

UR

ITY

, V

OIC

E &

TE

LE

CO

M.

5R

EF

ER

TO

TU

NN

EL D

WG

S F

OR

PA

TH

WA

YS

TH

AT

AR

E IN

CLU

DE

D A

S A

PO

RT

ION

OF

TH

AT

PR

OJE

CT

. C

OO

RD

INA

TE

WIT

HT

UN

NE

L C

ON

TR

AC

TO

R.

I/R DATE DESCRIPTION

2013.12.20 50% CCT GMP PACKAGE

2014.02.12 50% TOWER GMP

2014.03.31 TOWER BID SET

2014.11.03 CONSOLIDATED GMP FINAL

2015.06.24 BRIDGE CD PROGRESS SET

2015.09.22 ISSUE FOR CONSTRUCTION

TE

LE

CO

M K

EY

NO

TE

LE

GE

ND

NO

TE

#K

EY

NO

TE

TE

XT

1C

ON

TR

AC

TO

R T

O IN

ST

ALL (

5)

3"

CO

ND

UIT

S D

OW

N C

HA

SE

BE

TW

EE

N C

OLU

MN

S 5

.2.A

ND

5.3

AN

D C

ON

TIN

UE

ALO

NG

NE

W F

LO

OR

DE

CK

ING

UN

DE

R B

RID

GE

TO

ID

F 1

202.

2015.10.16 FINAL ISSUED FOR CONSTRUCTION

SERVICES OF ILLINOIS, INC.

RFI 485

RFI485

Page 15: GENERAL TELECOM NOTES

FDU

FDU

FDU

FDU

FDU

FDU

FDU

FDU

FDU

FDU

FDU

FDU

FDU

FDU

FDU

FDU

FDU

FDU

PH

ON

ES

WIT

CH

CAB

INE T

S

TGB

CC

T-3-

1C

CT-

3-2

CC

T-3-

38'

Hx8

'W F

IRE

TREA

TED

PLYW

OO

D B

ACKB

OAR

D

LAD

DER

RAC

K8'

Hx8

'W F

IRE

TREA

TED

PLYW

OO

D B

ACKB

OAR

DFD

UV

OIC

E

VO

ICE

FDU

FDU

FDU

FDU

FDU

FDU

FDU

FDU

FDU

FDU

BX-

XX-X

WAL

LR

ACK

CA-

XX-X

CA-

XX-X

LEVE

L-1

CC

T-B1

-1C

CT-

B1-2

CC

T-B1

-3C

CT-

B1-4

CC

T-B1

-5C

CT-

B1-6

CC

T-B1

-7C

CT-

B1-8

CC

T-B1

-9C

CT-

B1 -

10C

CT-

B1 -

11C

CT-

B1 -

12C

CT-

B1 -

13C

CT-

B1 -

14C

CT-

B1 -

15

CC

T-1-

1C

CT-

1-2

CC

T-2-

1C

CT-

2-2

CC

T-2-

3

CC

T-4-

1C

CT-

4-2

CC

T-4-

3

CC

T-5-

1C

CT-

5-2

CC

T-5-

3

CC

T-6-

1C

CT-

6-2

CC

T-6-

3

CC

T-7-

1C

CT-

7-2

CC

T-7-

3

CC

T-8-

1C

CT-

8-2

CC

T-8-

3

8'H

x8'W

FIR

E TR

EATE

DPL

YWO

OD

BAC

KBO

ARD

8'H

x8'W

FIR

E TR

EATE

DPL

YWO

OD

BAC

KBO

ARD

8'H

x8'W

FIR

E TR

EATE

DPL

YWO

OD

BAC

KBO

ARD

8'H

x8'W

FIR

E TR

EATE

DPL

YWO

OD

BAC

KBO

ARD

8'H

x8'W

FIR

E TR

EATE

DPL

YWO

OD

BAC

KBO

ARD

8'H

x8'W

FIR

E TR

EATE

DPL

YWO

OD

BAC

KBO

ARD

8'H

x8'W

FIR

E TR

EATE

DPL

YWO

OD

BAC

KBO

ARD

8'H

x8'W

FIR

E TR

EATE

DPL

YWO

OD

BAC

KBO

ARD

MD

F B1

-008

IDF -

120 2

TMG

B

TGB

TGB

TGB

TGB

TGB

TGB

TGB

NEU

TRA

L BU

S

GR

OU

ND

(EAR

TH) B

US

MA I

NEL

ECTR

ICAL

RM

4/0

AW

G B

Y E.

C.

4/0

AW

G B

Y E.

C.

4/0

AW

G B

Y E.

C.

4/0

AW

G B

Y E.

C.

4/0

AW

G B

Y E.

C.

4/0

AW

G B

Y E.

C.

4/0

AW

G B

Y E.

C.

4/0

AW

G B

Y E.

C.

4/0

AW

G B

Y E.

C.

LAD

DER

RAC

K

LAD

DER

RAC

K

LAD

DER

RAC

K

LAD

DER

RAC

K

LAD

DER

RAC

K

LAD

DER

RAC

K

LAD

DER

RAC

K

LAD

DER

RAC

K

8'H

x8'W

FIR

E TR

EATE

DPL

YWO

OD

BAC

KBO

ARD

8'H

x8'W

FIR

E TR

EATE

DPL

YWO

OD

BAC

KBO

ARD

8'H

x8'W

FIR

E TR

EATE

DPL

YWO

OD

BAC

KBO

ARD

8'H

x8'W

FIR

E TR

EATE

DPL

YWO

OD

BAC

KBO

ARD

8'H

x8'W

FIR

E TR

EATE

DPL

YWO

OD

BAC

KBO

ARD

8'H

x8'W

FIR

E TR

EATE

DPL

YWO

OD

BAC

KBO

ARD

8'H

x8'W

FIR

E TR

EATE

DPL

YWO

OD

BAC

KBO

ARD

FDU

FDU

FDU

FDU

FDU

FDU

FDU

48-S

TRA N

DO

M4

CO

RE

SW

ITC

HC

OR

ES

WIT

CH

VO

ICE

VO

ICE

VO

ICE

VO

ICE

VO

ICE

VO

ICE

VO

ICE

VO

ICE

VO

ICE

VO

ICE

VO

ICE

VO

ICE

VO

ICE

VO

ICE

25-P

AIR

CAT

5E F

OR

AN

ALO

GVO

ICE

& (2

) RG

-11

FOR

FUTU

RE

VID

EO

LEVE

L-B 1

LAD

DER

RAC

K

FDU

VO

ICE

VO

ICE

CC

T TO

WER

B AB C

OX

LAD

DER

RAC

K

FDU

VO

ICE

VO

ICE

BX-

1-1

LAD

DER

RAC

K

FDU

VO

ICE

VO

ICE

IDF

1-24

21

IDF

1-11

37ID

F 1-

1138

MD

F (E

X IST

ING

)

BX-

1-2

BX-

2-1

BX-

2-2

BX-

1-3

SEC

UR

I TY

ELEC

. 1-B

125

A NN

EX

MA S

TER

CO

NTR

OL

RM

(EX I

STIN

G)

T UN

NE L

MD

F(E

X IST

ING

)

B RID

GE

IDF

(EXI

STIN

G)

BX-

1-4

8'H

x8'W

FIR

E TR

EATE

D P

LYW

OO

DB

ACK

BOAR

D F

OR

VO

ICE

CAB

LIN

G W

A LL

FIEL

D A

ND

CR

OSS

-CO

NN

ECT

48-S

TRA N

DO

M4

25-P

AIR

CAT

5E F

OR

AN

ALO

GVO

ICE

& (2

) RG

-11

FOR

FUTU

RE

VID

EO

48-S

TRA N

DO

M4

48-S

TRA N

DO

M4

25-P

AIR

CAT

5E F

OR

AN

ALO

GVO

ICE

& (2

) RG

-11

FOR

FUTU

RE

VID

EO

25' C

OIL

EDFO

R F

UTU

RE

25' C

OIL

EDFO

R F

UTU

RE

48-S

TRA N

DO

M4

25-P

AIR

CAT

5E F

OR

AN

ALO

GVO

ICE

& (2

) RG

-11

FOR

FUTU

RE

VID

EO

48-S

TRA N

DO

M4

25-P

AIR

CAT

5E F

OR

AN

ALO

GVO

ICE

& (2

) RG

-11

FOR

FUTU

RE

VID

EO

48-S

TRA N

DO

M4

25-P

AIR

CAT

5E F

OR

AN

ALO

GVO

ICE

& (2

) RG

-11

FOR

FUTU

RE

VID

EO

48-S

TRA N

DO

M4

25-P

AIR

CAT

5E F

OR

AN

ALO

GVO

ICE

& (2

) RG

-11

FOR

FUTU

RE

VID

EO

48-S

TRA N

DO

M4

25-P

AIR

CAT

5E F

OR

AN

ALO

GVO

ICE

& (2

) RG

-11

FOR

FUTU

RE

VID

EO

IDF -

200 6

IDF -

331 2

IDF -

431 2

IDF -

531 2

IDF -

631 2

IDF -

731 2

IDF -

831 2

LEVE

L-2

LEVE

L-3

LEVE

L-4

LEVE

L-5

LEVE

L-6

LEVE

L-7

LEVE

L-8

PEN

THO

USE

LEV

E L

TGB

TGB

TGB

TGB

LAD

DER

RAC

K

FDU

VO

ICE

VO

ICE

BX-

B-1

BX-

B-2

8'H

x8'W

FIR

ETR

EATE

DP

LYW

OO

DB

ACKB

OAR

D

FUTU

RE

RAC

KS,

BAC

KBO

A RD

S AN

DE

QU

IPM

ENT

TYPI

CAL

TH

ISR

OO

M

CO

UR

T A D

MIN

PHO

NE

SWIT

CH

RO

OM

(EX I

STIN

G)

48-S

TRA N

D O

M4

AND

24-S

TRA N

D O

S2SE

E TU

NN

ELPA

CKA

GE

CAB

LIN

GBY

OTH

ERS

100

PAI R

CA

T 5E

SEE

TUN

NEL

PAC

KAG

E C

ABLI

NG

BY O

THER

S

TUN

NE L

PH

ASE

PULL

BO

X

48-S

TRA N

D O

M4

AN

D24

-STR

A ND

OS2

8'H

x8'W

FIR

ETR

EATE

DP

LYW

OO

DB

ACKB

OAR

D

8'H

x8'W

FIR

ETR

EATE

DP

LYW

OO

DB

ACKB

OAR

D

VO

ICE

CAB

LIN

G W

ALL

FIEL

D A

ND

CR

OSS

-CO

NN

ECT

48-S

TRAN

DO

M4

100

PAI R

CAT

5E

25-P

AIR

CAT

5E F

OR

AN

ALO

GVO

ICE

& (2

) RG

-11

FOR

FUTU

RE

VID

EO

25-P

AIR

CAT

5E F

OR

AN

ALO

G V

OIC

E &

(2)

RG

-11

F OR

FU

TUR

EV

IDEO

25' C

OIL

EDFO

R F

UTU

RE

CC

T-2-

48'

Hx8

'W F

IRE

TREA

TED

PLYW

OO

D B

ACKB

OAR

D TGB

LAD

DER

RAC

K

FDU

VO

ICE

VO

ICE

IDF -

220 1

B

4/0

AW

G B

Y E.

C.

PROJECT

CLIENT

REGISTRATION

LAKE COUNTY18 N. COUNTY STREETWAUKEGAN, ILLINOIS847.377.2929 tel 847.984.5889 fax

STRUCTURALAECOM999 TOWN AND COUNTRY ROADORANGE, CA 92868312.373.7700 tel 312.938.1109 faxwww.aecom.com

MEP/FPSYSKA HENNESSY GROUP, INC.330 N. WABASH AVE.CHICAGO, IL. 60611 SUITE 1505312.588.3561 tel 312.588.3579 faxwww.syska.com

CODE/LIFE SAFETYROLF JENSEN & ASSOCIATED, INC.600 WEST FULTON STREETCHICAGO, IL. 60661312.879.7200 tel 312.879.7200 faxwww.rjainc.com

ISSUE/REVISION

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

Last

Plo

tted:

File

nam

e:

Printed on ___% Post-ConsumerRecycled Content Paper

ARC

H E

1 30

" x 4

2"Pr

ojec

t Man

agem

ent I

nitia

ls:

Che

cked

:Ap

prov

ed:

123456

A

B

C

D

E

6 5 4 3 2 1

CONSULTANTS

ARCHITECT

AECOM303 EAST WACKER DRIVE,CHICAGO, IL 60601312.373.7700 tel 312.938.1109 faxwww.aecom.com

CIVILCHRISTOPHER B. BURKE, LTD.9575 W. HIGGINS ROADROSEMONT, IL. 60018 SUITE 600847.823.0500 tel 847.823.0520 fax

LANDSCAPEAECOM303 EAST WACKER DRIVE,CHICAGO, IL. 60601 SUITE 600312.373.7792 telwww.aecom.com

DATA TELCOM / AUDIO VISUALAECOM800 LASALLE AVEMINNEAPOLIS, MN 55402 SUITE 400612.376.2169 telwww.aecom.com

ELECTRONIC SECURITYAECOM2950 PROFESSIONAL PLACECOLORADO SPRINGS, CO 80904 SUITE 201719.386.8309 tel 719.386.8339 faxwww.aecom.com

FOOD SERVICES1 FOOD SERVICE231 HOMEWOOD DRIVEBOLINGBROOK, IL 60440630.783.9232 telhttp://s1foodservice.com/

9/22

/201

5 12

:30:

30 P

MC

:\Use

rs\c

anci

oa\D

ocum

ents

\LC

CH

_TO

WER

_T12

_CEN

TRAL

_can

cioa

.rvt

LAKE COUNTYCOURTHOUSEEXPANSION

WAUKEGAN, ILLINOIS 60085301 WASHINGTON STREET

TELECOM CABLING RISERDIAGRAM

2.T602

60288271

N OLE

KE

SCALE: 3/16" = 1'-0"

VOICE/DATA GROUNDING & CABLING RISER DIAGRAM- ROTATED 90 DEGREES

GEN

ERAL

TEL

ECO

M C

ABLI

NG

RIS

ER N

OTE

S1

REF

ER T

O T

UN

NEL

DW

GS

FOR

PAT

HW

AYS

THAT

AR

E IN

CLU

DED

AS

A PO

RTI

ON

OF

THAT

PR

OJE

CT.

CO

OR

DIN

ATE

WIT

H T

UN

NEL

CO

NTR

ACTO

R.

2AL

L FI

BER

OPT

IC B

ACKB

ON

E C

ABLI

NG

SH

ALL

SUPP

OR

T AU

DIO

-VID

EO, S

ECU

RIT

Y, V

OIC

E &

TELE

CO

M.

3EX

ISTI

NG

EQ

UIP

MEN

T SH

OW

N IS

FO

R R

EFER

ENC

E O

NLY

. FIE

LD V

ERIF

Y EX

ACT

EXIS

TIN

G C

ON

DIT

ION

S.PR

OVI

DE

NEW

PAT

CH

PAN

ELS,

110

BLO

CK,

AN

D F

IBER

DIS

TRIB

UTI

ON

S AS

REQ

UIR

ED F

OR

NEW

CAB

LIN

GIN

STAL

LED

IN E

XIST

ING

RO

OM

S.4

TER

MIN

ATE

ALL

CO

AX (R

G-1

1) C

ABLI

NG

AT

WAL

L FI

ELD

DIR

ECTI

ON

AL C

OU

PLER

.

I/R DATE DESCRIPTION

2013.12.20 50% CCT GMP PACKAGE2014.02.12 50% TOWER GMP2014.03.31 TOWER BID SET2014.11.03 CONSOLIDATED GMP FINAL2015.06.24 BRIDGE CD PROGRESS SET2015.09.22 ISSUE FOR CONSTRUCTION2015.10.16 FINAL ISSUED FOR CONSTRUCTION

SERVICES OF ILLINOIS, INC.

Page 16: GENERAL TELECOM NOTES

ACM-114C-110A-D15

TENANT ID

ORIGIN (IDF ROOM/RACK#)

ROOM/OUTLET #

PORT #

LABEL BETWEEN 4"=12"OF PATCH PANEL ANDWITHIN 2" AT OUTLET

.

ACM-131K16-F001-IDF01

TENANT ID

RACK ID (ROOM/RACK #)

CABLE BUNDLE # (F=FIBER)

RACK ID (ROOM/RACK #)

LABEL BETWEEN 4"-8" AT PANEL

.

HUNG CEILING

TOP OF FLOOR HALLWAY/CORRIDOR

WALL

WALL

RECESSED FLOOR BOXIN SLAB - TYPICAL

CONDUIT(1") (U.N.O.)

STEEL COMPRESSIONCOUPLING

WRENCH TIGHT

EMT CONNECTOR

INSULATED BUSHING(TYPICAL)

2-GANG RECESSED STEELJUNCTION BOX (TYPICAL).SEE SYMBOL LEGEND ANDPLANS FOR SPECIFICMOUNTING HEIGHTS

COMMUNICATION OUTLETFACEPLATE W/SINGLE-GANG MUD-RING (TYPICAL)

CABLE BUNDLESWITH CABLEHANGAR

RECESSEDHALLWAY LIGHTING(TYPICAL)

BUSHING (NYLON)

TO SUPPORT CABLE TRAY, UTILIZETHREADED ROD ANCHORED TO DECKABOVE AND/OR WALL-MOUNTBRACKETS. UTILIZE CHANNEL STRUT TOSUPPORT TRAY WHEN OFFSET RODSARE PLACED TO AVOID DUCTS ANDOTHER UTILITY PIPING.

CABLE TRAYCONDUIT IN WALLOR FURRED OUT

COLUMN (1")(U.N.O.)

DETAIL NOTES1. STUB END OF CONDUIT TO CLOSEST CABLE TRAY OR J-HOOK PATHWAY.

2.TELECOMMUNICATION OUTLET BOXES SHALL BE 2-GANG RECESSED JUNCTIONBOXES WITH SINGLE-GANG MUD RINGS, UNLESS OTHERWISE NOTED.

3. UNLESS OTHERWISE NOTED, ALL CONDUIT FOR HORIZONTALTELECOMMUNICATIONS CABLING SHALL BE A MINIMUM OF 1" EMT, STUBBED ABOVEACCESSIBLE CEILING W/INSULATED BUSHING. SEE CONDUIT SIZING TABLE FORADDITIONAL INFORMATION.

4. TELECOMMUNICATIONS WALL OUTLETS SHALL BE ALIGNED WITH ADJACENTELECTRICAL RECEPTACLES WHERE THEY ARE LOCATED WITHIN THE SAME VICINITYIN A NEAT AND WORKMANSHIP LIKE MANNER.

5. FOR FLOOR LOCATIONS, COORDINATE RACEWAY FOR TELECOMMUNICATIONSOUTLET(S) WITH ELECTRICAL RECEPTACLE LOCATIONS AND ENCLOSURES.

6. ALL CONDUITS SHALL BE EQUIPPED WITH PULL STRINGS.

7. ALL TELECOMMUNICATIONS EXPOSED (FREE-AIR)COPPER TWISTED PAIR CABLING(UNSHIELDED, SHIELDED; ETC) SHALL NOT BE WITHIN 12" OF ANY FLUORESCENTLIGHTING AND/OR LIGHTING BALLASTS.

TO SUPPORT CABLE BUNDLESWITH CABLE DROP WIREHANGAR, UTILIZE HANGERCLIPS AND DROP WIREANCHORED TO DECK ABOVE.

HALLWAY/COORIDOR SIDE

TELECOM ROOM SIDE

TYPICAL WIRE MESH TRAY

TYPICAL TELECOM CABLE

PENETRATION 4" DIA. RIGID CONDUIT SLEEVE

FIRESTOP EMPTY CONDUIT AND AFTER CABLE PULL

NOTE:

1. FIRESTOP SYSTEMS ARE BASED ON 3M FIRESTOP PRODUCTS.

2. SEAL ALL PATHWAYS WITH ONLY UL LISTED FIRESTOP SYSTEMS.

3. PRECISELY FOLLOW MANUFACTURERS INSTALLATION DIRECTIONS.

4. USE APPROPRIATE FIRESTOP SYSTEM DEIGNATED FOR THE PENETRATION.

5. USE FIRESTOP SYSTEM THAT AT LEAST EQUALS FIRE RATING OF PARTITION.

PROPERLY SEAL PENETRATIONSUSING APPROVED METHODSTO MAINTAIN THE FIRE/SMOKERATING OF THE FLOOR. SEESPECIFICATIONS FOR APPROVEDMANUFACTURERS AND MATERIAL.

SEAL ALL CONDUITS (INCLUDINGSPARES) AFTER COMMUNICATIONCABLES HAVE BEEN PULLED. SEESPECIFICATIONS FOR APPROVEDMANUFACTURERS AND MATERIAL.

(4") INTERMEDIATEMETAL CONDUIT,UNLESS OTHERWISE(TYPICAL) FINISH FLOOR

INSULATEDBUSHING(TYPICAL)

INSULATEDBUSHING(TYPICAL)

NOTES1.COORDINATE WITH PLANS AND SPECIFICATIONS, WHERE RE-ENTERABLE PATHWAY SYSTEM IS USED SHALL UTILIZE SIMILAR FIREAND SMOKE BARRIER SYSTEMS.

KEYPLAN LEGEND:0 - CAMPUS/ SITE1 - (E) BABCOX2 - COURT TOWER3 - TUNNEL4 - (E) COURT ADMIN5 - (E) BRIDGE

N

PROJECT

CLIENT

REGISTRATION

LAKE COUNTY18 N. COUNTY STREETWAUKEGAN, ILLINOIS847.377.2929 tel 847.984.5889 fax

STRUCTURALAECOM999 TOWN AND COUNTRY ROADORANGE, CA 92868312.373.7700 tel 312.938.1109 faxwww.aecom.com

MEP/FPSYSKA HENNESSY GROUP, INC.330 N. WABASH AVE.CHICAGO, IL. 60611 SUITE 1505312.588.3561 tel 312.588.3579 faxwww.syska.com

CODE/LIFE SAFETYROLF JENSEN & ASSOCIATED, INC.600 WEST FULTON STREETCHICAGO, IL. 60661312.879.7200 tel 312.879.7200 faxwww.rjainc.com

ISSUE/REVISION

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

Last

Plo

tted:

File

nam

e:

Printed on ___% Post-ConsumerRecycled Content Paper

ARC

H E

1 30

" x 4

2"Pr

ojec

t Man

agem

ent I

nitia

ls:

Che

cked

:Ap

prov

ed:

123456

A

B

C

D

E

6 5 4 3 2 1

CONSULTANTS

ARCHITECT

AECOM303 EAST WACKER DRIVE,CHICAGO, IL 60601312.373.7700 tel 312.938.1109 faxwww.aecom.com

CIVILCHRISTOPHER B. BURKE, LTD.9575 W. HIGGINS ROADROSEMONT, IL. 60018 SUITE 600847.823.0500 tel 847.823.0520 fax

LANDSCAPEAECOM303 EAST WACKER DRIVE,CHICAGO, IL. 60601 SUITE 600312.373.7792 telwww.aecom.com

DATA TELCOM / AUDIO VISUALAECOM800 LASALLE AVEMINNEAPOLIS, MN 55402 SUITE 400612.376.2169 telwww.aecom.com

ELECTRONIC SECURITYAECOM2950 PROFESSIONAL PLACECOLORADO SPRINGS, CO 80904 SUITE 201719.386.8309 tel 719.386.8339 faxwww.aecom.com

KEY PLANSCALE: N.T.S.

FOOD SERVICES1 FOOD SERVICE231 HOMEWOOD DRIVEBOLINGBROOK, IL 60440630.783.9232 telhttp://s1foodservice.com/

1A1C

1B

35

4

2

9/22

/201

5 1:

05:1

4 PM

C:\U

sers

\can

cioa

\Doc

umen

ts\L

CC

H_T

UN

NEL

_T12

_CEN

TRAL

_can

cioa

.rvt

LAKE COUNTYCOURTHOUSEEXPANSION

WAUKEGAN, ILLINOIS 60085301 WASHINGTON STREET

TELECOM DETAILS

3.T500

60288271

Che

cker

SCALE: 12" = 1'-0"3.T500

3 TWISTED PAIR CABLE LABELINGSCALE: 12" = 1'-0"3.T500

4 FIBER OPTIC CABLE LABELING

SCALE: 12" = 1'-0"3.T500

1 TELECOMMUNICATIONS INFRASTRUCTURE AND ASSEMBLIES ROUGH-IN DETAIL

SCALE: 12" = 1'-0"3.T500

2 FIRE RATED WALL PENETRATION DETAIL

SCALE: 12" = 1'-0"3.T500

5 CONDUIT RISER FLOOR PENETRATION DETAIL

I/R DATE DESCRIPTION

2013.12.02 50% TUNNEL GMP PACKAGE

2014.01.31 FOUNDATION AND TUNNELBID SET

2014.11.03 CONSOLIDATED GMP FINAL2015.09.22 ISSUE FOR CONSTRUCTION

SERVICES OF ILLINOIS, INC.

2015.10.16 FINAL ISSUED FOR CONSTRUCTION

Page 17: GENERAL TELECOM NOTES

ACM-114C-110A-D15

TENANT ID

ORIGIN (IDF ROOM/RACK#)

ROOM/OUTLET #

PORT #

LABEL BETWEEN 4"=12"OF PATCH PANEL ANDWITHIN 2" AT OUTLET

.

ACM-131K16-F001-IDF01

TENANT ID

RACK ID (ROOM/RACK #)

CABLE BUNDLE # (F=FIBER)

RACK ID (ROOM/RACK #)

LABEL BETWEEN 4"-8" AT PANEL

.

HUNG CEILING

TOP OF FLOOR HALLWAY/CORRIDOR

WALL

WALL

RECESSED FLOOR BOXIN SLAB - TYPICAL

CONDUIT(1") (U.N.O.)

STEEL COMPRESSIONCOUPLING

WRENCH TIGHT

EMT CONNECTOR

INSULATED BUSHING(TYPICAL)

2-GANG RECESSED STEELJUNCTION BOX (TYPICAL).SEE SYMBOL LEGEND ANDPLANS FOR SPECIFICMOUNTING HEIGHTS

COMMUNICATION OUTLETFACEPLATE W/SINGLE-GANG MUD-RING (TYPICAL)

CABLE BUNDLESWITH CABLEHANGAR

RECESSEDHALLWAY LIGHTING(TYPICAL)

BUSHING (NYLON)

TO SUPPORT CABLE TRAY, UTILIZETHREADED ROD ANCHORED TO DECKABOVE AND/OR WALL-MOUNTBRACKETS. UTILIZE CHANNEL STRUT TOSUPPORT TRAY WHEN OFFSET RODSARE PLACED TO AVOID DUCTS ANDOTHER UTILITY PIPING.

CABLE TRAYCONDUIT IN WALLOR FURRED OUT

COLUMN (1")(U.N.O.)

DETAIL NOTES1. STUB END OF CONDUIT TO CLOSEST CABLE TRAY OR J-HOOK PATHWAY.

2.TELECOMMUNICATION OUTLET BOXES SHALL BE 2-GANG RECESSED JUNCTIONBOXES WITH SINGLE-GANG MUD RINGS, UNLESS OTHERWISE NOTED.

3. UNLESS OTHERWISE NOTED, ALL CONDUIT FOR HORIZONTALTELECOMMUNICATIONS CABLING SHALL BE A MINIMUM OF 1" EMT, STUBBED ABOVEACCESSIBLE CEILING W/INSULATED BUSHING. SEE CONDUIT SIZING TABLE FORADDITIONAL INFORMATION.

4. TELECOMMUNICATIONS WALL OUTLETS SHALL BE ALIGNED WITH ADJACENTELECTRICAL RECEPTACLES WHERE THEY ARE LOCATED WITHIN THE SAME VICINITYIN A NEAT AND WORKMANSHIP LIKE MANNER.

5. FOR FLOOR LOCATIONS, COORDINATE RACEWAY FOR TELECOMMUNICATIONSOUTLET(S) WITH ELECTRICAL RECEPTACLE LOCATIONS AND ENCLOSURES.

6. ALL CONDUITS SHALL BE EQUIPPED WITH PULL STRINGS.

7. ALL TELECOMMUNICATIONS EXPOSED (FREE-AIR)COPPER TWISTED PAIR CABLING(UNSHIELDED, SHIELDED; ETC) SHALL NOT BE WITHIN 12" OF ANY FLUORESCENTLIGHTING AND/OR LIGHTING BALLASTS.

TO SUPPORT CABLE BUNDLESWITH CABLE DROP WIREHANGAR, UTILIZE HANGERCLIPS AND DROP WIREANCHORED TO DECK ABOVE.

HALLWAY/COORIDOR SIDE

TELECOM ROOM SIDE

TYPICAL WIRE MESH TRAY

TYPICAL TELECOM CABLE

PENETRATION 4" DIA. RIGID CONDUIT SLEEVE

FIRESTOP EMPTY CONDUIT AND AFTER CABLE PULL

NOTE:

1. FIRESTOP SYSTEMS ARE BASED ON 3M FIRESTOP PRODUCTS.

2. SEAL ALL PATHWAYS WITH ONLY UL LISTED FIRESTOP SYSTEMS.

3. PRECISELY FOLLOW MANUFACTURERS INSTALLATION DIRECTIONS.

4. USE APPROPRIATE FIRESTOP SYSTEM DEIGNATED FOR THE PENETRATION.

5. USE FIRESTOP SYSTEM THAT AT LEAST EQUALS FIRE RATING OF PARTITION.

PROPERLY SEAL PENETRATIONSUSING APPROVED METHODSTO MAINTAIN THE FIRE/SMOKERATING OF THE FLOOR. SEESPECIFICATIONS FOR APPROVEDMANUFACTURERS AND MATERIAL.

SEAL ALL CONDUITS (INCLUDINGSPARES) AFTER COMMUNICATIONCABLES HAVE BEEN PULLED. SEESPECIFICATIONS FOR APPROVEDMANUFACTURERS AND MATERIAL.

(4") INTERMEDIATEMETAL CONDUIT,UNLESS OTHERWISE(TYPICAL) FINISH FLOOR

INSULATEDBUSHING(TYPICAL)

INSULATEDBUSHING(TYPICAL)

NOTES1.COORDINATE WITH PLANS AND SPECIFICATIONS, WHERE RE-ENTERABLE PATHWAY SYSTEM IS USED SHALL UTILIZE SIMILAR FIREAND SMOKE BARRIER SYSTEMS.

KEYPLAN LEGEND:0 - CAMPUS/ SITE1 - (E) BABCOX2 - COURT TOWER3 - TUNNEL4 - (E) COURT ADMIN5 - (E) BRIDGE

N

PROJECT

CLIENT

REGISTRATION

LAKE COUNTY18 N. COUNTY STREETWAUKEGAN, ILLINOIS847.377.2929 tel 847.984.5889 fax

STRUCTURALAECOM999 TOWN AND COUNTRY ROADORANGE, CA 92868312.373.7700 tel 312.938.1109 faxwww.aecom.com

MEP/FPSYSKA HENNESSY GROUP, INC.330 N. WABASH AVE.CHICAGO, IL. 60611 SUITE 1505312.588.3561 tel 312.588.3579 faxwww.syska.com

CODE/LIFE SAFETYROLF JENSEN & ASSOCIATED, INC.600 WEST FULTON STREETCHICAGO, IL. 60661312.879.7200 tel 312.879.7200 faxwww.rjainc.com

ISSUE/REVISION

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

Last

Plo

tted:

File

nam

e:

Printed on ___% Post-ConsumerRecycled Content Paper

ARC

H E

1 30

" x 4

2"Pr

ojec

t Man

agem

ent I

nitia

ls:

Che

cked

:Ap

prov

ed:

123456

A

B

C

D

E

6 5 4 3 2 1

CONSULTANTS

ARCHITECT

AECOM303 EAST WACKER DRIVE,CHICAGO, IL 60601312.373.7700 tel 312.938.1109 faxwww.aecom.com

CIVILCHRISTOPHER B. BURKE, LTD.9575 W. HIGGINS ROADROSEMONT, IL. 60018 SUITE 600847.823.0500 tel 847.823.0520 fax

LANDSCAPEAECOM303 EAST WACKER DRIVE,CHICAGO, IL. 60601 SUITE 600312.373.7792 telwww.aecom.com

DATA TELCOM / AUDIO VISUALAECOM800 LASALLE AVEMINNEAPOLIS, MN 55402 SUITE 400612.376.2169 telwww.aecom.com

ELECTRONIC SECURITYAECOM2950 PROFESSIONAL PLACECOLORADO SPRINGS, CO 80904 SUITE 201719.386.8309 tel 719.386.8339 faxwww.aecom.com

KEY PLANSCALE: N.T.S.

FOOD SERVICES1 FOOD SERVICE231 HOMEWOOD DRIVEBOLINGBROOK, IL 60440630.783.9232 telhttp://s1foodservice.com/

1A1C

1B

35

4

2

9/22

/201

5 1:

05:1

4 PM

C:\U

sers

\can

cioa

\Doc

umen

ts\L

CC

H_T

UN

NEL

_T12

_CEN

TRAL

_can

cioa

.rvt

LAKE COUNTYCOURTHOUSEEXPANSION

WAUKEGAN, ILLINOIS 60085301 WASHINGTON STREET

TELECOM DETAILS

3.T500

60288271

Che

cker

SCALE: 12" = 1'-0"3.T500

3 TWISTED PAIR CABLE LABELINGSCALE: 12" = 1'-0"3.T500

4 FIBER OPTIC CABLE LABELING

SCALE: 12" = 1'-0"3.T500

1 TELECOMMUNICATIONS INFRASTRUCTURE AND ASSEMBLIES ROUGH-IN DETAIL

SCALE: 12" = 1'-0"3.T500

2 FIRE RATED WALL PENETRATION DETAIL

SCALE: 12" = 1'-0"3.T500

5 CONDUIT RISER FLOOR PENETRATION DETAIL

I/R DATE DESCRIPTION

2013.12.02 50% TUNNEL GMP PACKAGE

2014.01.31 FOUNDATION AND TUNNELBID SET

2014.11.03 CONSOLIDATED GMP FINAL2015.09.22 ISSUE FOR CONSTRUCTION

SERVICES OF ILLINOIS, INC.

2015.10.16 FINAL ISSUED FOR CONSTRUCTION

Page 18: GENERAL TELECOM NOTES

CONTRACTOR TO FOLLOW 50% FILL RATE TABLE BELOWWHEN SIZING CABLE TRAY AND INSTALLING

TELECOMMUNICATIONS CABLE(S) WITHIN TRAY.

4PR PLENUM CAT 6130 174 260 394 253 331 496 751

CONTRACTOR TO FOLLOW 40% FILL RATE TABLE BELOW WHENSIZING CONDUIT AND INSTALLING TELECOMMUNICATIONS

CABLE(S) WITHIN CONDUIT. ASSUMES NO MORE THAN TWOLARGE RADIUS

90-DEGREE CONDUIT BENDS PER RUN.

CONDUIT SIZE:

4PR CAT 6 FILL QTY.

1"(*) 1.25" 1.5" 2" 2.5" 3" 3.5" 4"

6 12 16 27 39 60 80 103

998FILL QTY.

25mm 31mm 38mm 50mm 63mm 76mm 88mm 101mm

CABLE TRAY SIZEMETRIC mm (HxW):

50x152

50x203

50x304

50x457

100x152

100x203

100x304

100x457

100x609

DETAIL NOTES

1. PLENUM RATED CATEGORY 6 CABLE DIA. (GENERIC MANUFACTURER).

2. CONTRACTOR TO REVISE CABLE TRAY AND CONDUIT FILL QUANTITIESTO ACCOUNT FOR INCLUSION OTHER CABLE TYPES (BACKBONE VOICE,FIBER OPTIC. COAXIAL, ETC.) AS MAY BE INSTALLED AS PART OF THEPROJECT IN A PARTICULAR PORTION OF THE RACEWAY. CONTRACTORTO MAINTAIN MAXIMUM FILL PERCENTAGE RATES CITED FOR PATHWAYTYPES NOTED ABOVE.

3. CONTRACTOR TO SUBMIT REVISED CABLE FILL TABLES BASED UPONACTUAL CABLE DIA. FOR ENGINEER APPROVAL. CONTRACTOR-SUBMITTEDTABLES TO INCLUDE ADDITIONAL CABLE TRAY OR CONDUIT SIZES NOTLISTED ABOVE CONTRACTOR ANTICIPATES UTILIZING ON PROJECT.

4. (*) CONTRACTOR TO OBSERVE MINIMUM CONDUIT SIZE REQUIREMENTSAS NOTED IN COMMUNICATIONS OUTLETS CONDUIT DETAIL.

5. FILL RATIO OF 50% SHALL BE USED FOR CABLE TRAY SO AS TO PERMITFUTURE CABLE GROWTH WITHIN PHYSICAL BOUNDARY OF TRAY.

NOTE:THIS DETAIL AND MATRIX IS SHOWN FORREFERENCE ONLY ALL CONDUIT FILLS SHALL BEIN ACCORDANCE WITH ALL MANUFACTURERINSTALLATION INSTRUCTIONS AND EIA/TIACABLING AND PATHWAY STANDARDS.

DATA 1

VOICE 1

DATA 2

VOICE 2

OUTLET LABEL

4 POSITIONFACEPLATE

1 2 3 4 5 6 7 8

PIN#54123678

PAIR COLORT1-W/BLR1-BL/WT2-W/OR2-O/WT3-W/GRR3-GR/WT4-W/BRR4-BR/W

JACK TYPEDATA 1DATA 2VOICE 1VOICE 2

JACK COLORBLUEN/AIVORYIVORY

CABLECAT 6/BLUECAT 6/BLUE/WHITECAT 6A/GRAYCAT 6A/GRAY

RJ-45(T568A)

PR3 PR4

PR2

PR1

DRAWINGSYMBOL

XXXX-XX

XXXX-XX

DATA 1

VOICE 1

DATA 2

BLANK/SPARE 1

OUTLET LABEL

4 POSITIONFACEPLATE

1 2 3 4 5 6 7 8

PIN#54123678

PAIR COLORT1-W/BLR1-BL/WT2-W/OR2-O/WT3-W/GRR3-GR/WT4-W/BRR4-BR/W

JACK TYPEDATA 1DATA 2VOICE 1

JACK COLORBLUEN/AIVORY

CABLECAT 6/BLUECAT 6/BLUE/WHITECAT 6A/GRAY

RJ-45(T568A)

PR3 PR4

PR2

PR1

DRAWINGSYMBOL

XXXX-XX

XXXX-XX

DATA 1

VOICE 1

BLANK/SPARE 1

BLANK/SPARE 1

OUTLET LABEL

4 POSITIONFACEPLATE

1 2 3 4 5 6 7 8

PIN#54123678

PAIR COLORT1-W/BLR1-BL/WT2-W/OR2-O/WT3-W/GRR3-GR/WT4-W/BRR4-BR/W

JACK TYPEDATA 1VOICE 1

JACK COLORBLUEIVORY

CABLECAT 6/BLUECAT 6A/GRAY

RJ-45(T568A)

PR3 PR4

PR2

PR1

DRAWINGSYMBOL

XXXX-XX

XXXX-XX

THIS OUTLETCONFIGURATION APPLIESTO ALL WALL MOUNTVOIP/PHONELOCATIONS. SHALL BEMOUNTED AT +48" A.F.F.UNLESS OTHERWISE NOTED

OUTLET LABEL

VOICE 1

1 POSITIONFACEPLATE

1 2 3 4 5 6 7 8

PIN#54123678

PAIR COLORT1-W/BLR1-BL/WT2-W/OR2-O/WT3-W/GRR3-GR/WT4-W/BRR4-BR/W

JACK TYPEVOICE 1

JACK COLORIVORY

CABLECAT 6A/GRAY

RJ-45(T568A)

PR3 PR4

PR2

PR1

DRAWINGSYMBOL

XXXX-XX

XXXX-XX

OUTLET LABEL

DATA 1

1 POSITIONFACEPLATE

1 2 3 4 5 6 7 8

PIN#54123678

PAIR COLORT1-W/BLR1-BL/WT2-W/OR2-O/WT3-W/GRR3-GR/WT4-W/BRR4-BR/W

JACK TYPEDATA 1

JACK COLORBLUE

CABLECAT 6/BLUE

RJ-45(T568A)

PR3 PR4

PR2

PR1

DRAWINGSYMBOL

XXXX-XX

XXXX-XX

TV 1

TV

OUTLET LABEL

1 POSITIONFACEPLATE

1 2 3 4 5 6 7 8

PIN#54123678

PAIR COLORT1-W/BLR1-BL/WT2-W/OR2-O/WT3-W/GRR3-GR/WT4-W/BRR4-BR/W

JACK TYPEF-TYPE

JACK COLORSS

CABLERG6 PLENUMRATED

RJ-45(T568A)

PR3 PR4

PR2

PR1

DRAWINGSYMBOL

XXXX-XX

XXXX-XX

TV

OUTLET LABEL

(IPTV) DATA 1

1 POSITIONFACEPLATE

1 2 3 4 5 6 7 8

PIN#54123678

PAIR COLORT1-W/BLR1-BL/WT2-W/OR2-O/WT3-W/GRR3-GR/WT4-W/BRR4-BR/W

JACK TYPEDATA 1

JACK COLORBLUE

CABLECAT 6/BLUE

RJ-45(T568A)

PR3 PR4

PR2

PR1

DRAWINGSYMBOL

XXXX-XX

XXXX-XX

NOTE:COORDINATE WITH AVSHEETS FORNECESSARY LOCATIONS

P

OUTLET LABEL

PROJECTOR 1

1 POSITIONFACEPLATE

1 2 3 4 5 6 7 8

PIN#54123678

PAIR COLORT1-W/BLR1-BL/WT2-W/OR2-O/WT3-W/GRR3-GR/WT4-W/BRR4-BR/W

JACK TYPEPROJECTOR 1

JACK COLORBLUE

CABLECAT 6/BLUE

RJ-45(T568A)

PR3 PR4

PR2

PR1

DRAWINGSYMBOL

XXXX-XX

XXXX-XX

NOTE:VERIFY W/PLANS FORFLUSH IN CEILING ORABOVE CEILINGMOUNTING LOCATIONS,THIS TERMINATION ISFOR THE DATACONNECTION TO THEPROJECTOR AND NOTTHE A/V CONNECTION.SEE A/V SHEETS FORPROJECTOR CABLINGAND TERMINATIONREQUIREMENTS.

GROMMETED CABLEPASS-THRU TOFURNATUREEQUIPMENT

GROMMET HOLEFACEPLATE

DRAWINGSYMBOL

J

NOTE:THIS OUTLETCONFIGURATION APPLIESTO SYSTEM FURNATURELOCATIONS AND EQUIPMENTLOCATIONS. FOR SYSTEMFURNATURE LOCATIONS, THISCONFIGURATION WILL SERVE ASA PASS-THRU ONLY AND CABLESWILL TERMINATE AT FURNATUREOUTLET. COORDINATE CABLEINSTALLATION WITH SYSTEMFURNATURE INSTALLER.

PASS-THRU SIZED BASED ONCABLE QUANITIES AT EACHLOCATION SHOWN ON PLANS.PROVIDE PROTECTIVEBRUSSHED GROMMET ANDMESH-CELL INTERDUCT FROMWITHIN GROMMETED BOXROUTED THROUGH FURNATURESYSTEM.

1. ALL TELECOM CONDUIT STUBS SHALL BE A MINIMUM 1"EMT. ALL WALL OUTLET BOXESFOR TELECOM TERMINATIONS SHALL BE DUAL-GANG DEEP BOXES.

2. ALL HORIZONTAL CABLING SHALL BE CATAGORY 6 PLENUM RATED REGARDLESS OFINSTALLATION ENVIRONMENT.

3. CONTRACTOR TO FIELD VERIFY INSTALLATION. CONTRACTOR SHALL MAKE EVERYEFFORT TO PERFORM INSTALATION FOLLOWING LATEST GUIDELINES OF TIA-568/569/607

4. CONTRACTOR TO FOLLOW MANUFACTURER'S RECOMMENDED INSTALLATIONMETHODS/PRACTICES FOR CAT

5. ALL CABLING SHALL BE INSTALLED USING CABLE TRAY IN GENERAL PATHWAYS.

6. A TYPICAL STATION RUN WILL CONSIST OF TWO SHEATHS OF CATAGORY 6 CABLE FROMMDF/IDF TO A COMMUNICATIONS OUTLET. AS REQUIRED A SINGLE RUN OF CAT 6 WILL BEUSED FOR A WALL TELEPHONE OR SINGLE DATA LOCATION, OBSERVING THE CORRECTCOLOR CABLE AS LISTED.

7. ALL VOICE CABLING SHALL BE COMMSCOPE CAT 6, 4-PAIR UTP, 1071 FOR PVC AND 2071FOR PLENUM. THE COLOR OF THE VOICE CABLING SHALL BE IVORY, WHERE A SECONDWIRE FOR VOICE IS PRESENT SHALL BE IVORY WITH CONTRASTING COLORED STRIP.

8. ALL DATA CABLING SHALL BE COMMSCOPE CAT 6, 4-PAIR UTP, 1071 FOR PVC AND 2071FOR PLENUM. THE COLOR OF THE DATA CABLING SHALL BE BLUE, WHERE A SECOND WIREFOR DATA IS PRESENT SHALL BE IVORY WITH CONTRASTING COLORED STRIP.

9. ALL HVAC CABLING SHALL BE COMMSCOPE CAT 6, 4-PAIR UTP, 1071 FOR PVC AND 2071FOR PLENUM. THE COLOR OF THE DATA CABLING SHALL BE PURPLE, WHERE A SECONDWIRE FOR DATA IS PRESENT SHALL BE PURPLE WITH CONTRASTING COLORED STRIP.

10. ALL CABLE TV WILL BE COAX RG-6, 75 OHM COMMSCOPE 2277 (PLENUM) OR 5700 (NON-PLENUM) OR APPROVED EQUAL.

11. FACEPLATES SHALL BE IVORY, COORDINATE WITH SPECIFICATIONS ANDARCHITECTURAL INTERIOR FINISH PLANS.

12. ALL CAT-6A CABLES SHALL BE TERMINATED, LABELED AND TESTED

FACEPLATE GENERAL NOTES

1 2 3 4 5 6 7 8

PIN#54123678

PAIR COLORT1-W/BLR1-BL/WT2-W/OR2-O/WT3-W/GRR3-GR/WT4-W/BRR4-BR/W

JACK TYPEDATA 1

JACK COLORBLUE

CABLECAT 6/BLUE

RJ-45(T568A)

PR3 PR4

PR2

PR1

DRAWINGSYMBOL

AP

MALE RJ-45TERMINATEDDIRECTLY ATACCESS POINT,ROUTER OR WIFIHUB

OUTLET LABEL

DATA 1

1 POSITIONFACEPLATE

1 2 3 4 5 6 7 8

PIN#54123678

PAIR COLORT1-W/BLR1-BL/WT2-W/OR2-O/WT3-W/GRR3-GR/WT4-W/BRR4-BR/W

JACK TYPEDATA 1

JACK COLORBLUE

CABLECAT 6/BLUE

RJ-45(T568A)

PR3 PR4

PR2

PR1

DRAWINGSYMBOL

XXXX-XX

XXXX-XX

NOTE:VERIFY W/PLANS FORFLUSH IN CEILING ORABOVE CEILINGMOUNTING LOCATIONS

KEYPLAN LEGEND:0 - CAMPUS/ SITE1 - (E) BABCOX2 - COURT TOWER3 - TUNNEL4 - (E) COURT ADMIN5 - (E) BRIDGE

N

PROJECT

CLIENT

REGISTRATION

LAKE COUNTY18 N. COUNTY STREETWAUKEGAN, ILLINOIS847.377.2929 tel 847.984.5889 fax

STRUCTURALAECOM999 TOWN AND COUNTRY ROADORANGE, CA 92868312.373.7700 tel 312.938.1109 faxwww.aecom.com

MEP/FPSYSKA HENNESSY GROUP, INC.330 N. WABASH AVE.CHICAGO, IL. 60611 SUITE 1505312.588.3561 tel 312.588.3579 faxwww.syska.com

CODE/LIFE SAFETYROLF JENSEN & ASSOCIATED, INC.600 WEST FULTON STREETCHICAGO, IL. 60661312.879.7200 tel 312.879.7200 faxwww.rjainc.com

ISSUE/REVISION

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

Last

Plo

tted:

File

nam

e:

Printed on ___% Post-ConsumerRecycled Content Paper

ARC

H E

1 30

" x 4

2"Pr

ojec

t Man

agem

ent I

nitia

ls:

Che

cked

:Ap

prov

ed:

123456

A

B

C

D

E

6 5 4 3 2 1

CONSULTANTS

ARCHITECT

AECOM303 EAST WACKER DRIVE,CHICAGO, IL 60601312.373.7700 tel 312.938.1109 faxwww.aecom.com

CIVILCHRISTOPHER B. BURKE, LTD.9575 W. HIGGINS ROADROSEMONT, IL. 60018 SUITE 600847.823.0500 tel 847.823.0520 fax

LANDSCAPEAECOM303 EAST WACKER DRIVE,CHICAGO, IL. 60601 SUITE 600312.373.7792 telwww.aecom.com

DATA TELCOM / AUDIO VISUALAECOM800 LASALLE AVEMINNEAPOLIS, MN 55402 SUITE 400612.376.2169 telwww.aecom.com

ELECTRONIC SECURITYAECOM2950 PROFESSIONAL PLACECOLORADO SPRINGS, CO 80904 SUITE 201719.386.8309 tel 719.386.8339 faxwww.aecom.com

KEY PLANSCALE: N.T.S.

FOOD SERVICES1 FOOD SERVICE231 HOMEWOOD DRIVEBOLINGBROOK, IL 60440630.783.9232 telhttp://s1foodservice.com/

1A1C

1B

35

4

2

9/22

/201

5 1:

05:2

7 PM

C:\U

sers

\can

cioa

\Doc

umen

ts\L

CC

H_T

UN

NEL

_T12

_CEN

TRAL

_can

cioa

.rvt

LAKE COUNTYCOURTHOUSEEXPANSION

WAUKEGAN, ILLINOIS 60085301 WASHINGTON STREET

TELECOM DETAILS

3.T501

60288271

Che

cker

SCALE: 12" = 1'-0"3.T501

1 CABLE TRAY & CONDUIT FILL DETAIL

SCALE: 6" = 1'-0"3.T501

2 FP WALL VOICE/DATA LOCATION (2V,2D)SCALE: 6" = 1'-0"3.T501

3 FP WALL VOICE/DATA LOCATION (1V,2D)SCALE: 6" = 1'-0"3.T501

4 FP WALL VOICE/DATA LOCATION (1V,1D)

SCALE: 6" = 1'-0"3.T501

5 FP WALL VOICE LOCATION (1V)SCALE: 6" = 1'-0"3.T501

6 FP WALL DATA LOCATION (1D)SCALE: 6" = 1'-0"3.T501

7 FP TV LOCATION (RG-6)

SCALE: 6" = 1'-0"3.T501

8 FP TV LOCATION (IPTV)SCALE: 6" = 1'-0"3.T501

9 FP PROJECTOR LOCATION (1D)SCALE: 6" = 1'-0"3.T501

10 FP GROMMETED PASS-THRU LOCATION

SCALE: 6" = 1'-0"3.T501

12 FP DATA FOR CEILING ACCESS POINT (WIFI)SCALE: 6" = 1'-0"3.T501

13 FP CEILING DATA LOCATION (1D)

I/R DATE DESCRIPTION

2013.12.02 50% TUNNEL GMP PACKAGE

2014.01.31 FOUNDATION AND TUNNELBID SET

2014.11.03 CONSOLIDATED GMP FINAL2015.09.22 ISSUE FOR CONSTRUCTION

SERVICES OF ILLINOIS, INC.

2015.10.16 FINAL ISSUED FOR CONSTRUCTION