E
A9.55
H4
A9.55
F1
A9.55
H8
A9.55
F4
MAINTENANCEM104
COVERED PORCHM10522
' - 6
"
22' - 2" 0' - 5 1/2" 13' - 3 9/16" 1' - 5"
3' -
3"1'
- 5"
13' -
2"
1' -
5"3'
- 3"
22' -
6"
4' -
6"
C04
3' -
3"1'
- 5"
13' -
2"
1' -
5"
3' -
3"
MOP SINK
1/8:121/8:
12
F.E.
C.
C08
SURFACE MOUNTEDELECTRICAL PANEL
HOSE BIB
TD =
30'460/300 = (2)
C04
A9.55
H1
1/8
:12
1/8
:12
HVAC AND WATERHEATER BELOW
A9.55
H1
SIM
3' -
6"
2' - 6"
WORK BENCH
12"
TRASH ENCLOSURE- SEE SHEET A9.50
1/8
:12
RAISED 6" CURB
SLO
PE
LINE OF BEAM (ABOVE)
6' - 0"
3' - 1" 16' - 0" 3' - 1"
5' -
0"11
' - 1
1"5'
- 0"
5' - 0" 11' - 7" 5' - 0"
3' -
0"7'
- 2"
3' -
0"
3' - 0" 7' - 9" 3' - 0"
9' - 10 7/8"
9' - 10 7/8"
6:12
6:12
6:12
6:1
26
:12
6:12
7:1
2
1' - 6"
1' -
0"
1' - 0"
717.18SF
MAINTENANCE
A5.24
F7
1' -
0"
3' -
6"
2' -
0"2'
- 0"
KEYNOTES:01. CONCRETE ROOF TILE02. FIBER CEMENT FASCIA OR TRIM- SEE DETAILS FOR SIZE03. STUCCO SYSTEM04. E.P.S. WINDOW TRIM BAND - SEE DETAILS FOR SIZE05. E.P.S. SHAPE - SEE DETAILS FOR SIZE AND SHAPE06. E.P.S. WINDOW SILL07. E.P.S. TRIM BAND - SEE DETAIL FOR SIZE08. LIGHT FIXTURE - SEE ELECTRICAL09. DECORATIVE PIECE10. GUARD RAIL11. ELECTRICAL PANEL12. GUTTER13. DOWNSPOUT14. CONDENSING UNIT - SEE MECHANICAL15. DISCONNECT SWITCH FOR CONDENSING UNITS - SEE ELECTRICAL DRAWINGS16. METAL FASCIA17. STUCCO18. DECORATIVE PRECAST TRIM19. CERAMIC/TRAVERTINE TILE20. PIPE VENT - SEE PLUMBING21. EXHAUST FAN / DRYER VENT - SEE MECHANICAL22. BUILDING FIRE SIGN - SIGN TO BE LOCATED ON FRONT OF BUILDING ONLY - SEE
SITE PLAN FOR BUILDING ORIENTATION.23. RAIN DIVERTER (SEE DETAIL D1/A5.12)24. METER CENTER - SEE ELECTRICAL25. CONCRETE CAP26. PERGOLA27. DECORATIVE BRACKET28. GATE29. METAL POSTS30. ELECTRICAL PANEL / FIRE RISER ACCESS PANEL31. 4C HORIZONTAL MAILBOX - 18 MB1 DOORS/ 2 PL'S, FRONT LOADING MODEL
3716D-18: SALSBURY INDUSTRIES OR EQUAL (8 BOX CLUSTERS SERVE 136 UNITS)32. LAUNDRY / BATHROOM EXHAUST VENTS33. TRASH CHUTE DOOR34. RAISED METAL SIGN LETTERS35. DECORATIVE PVC BRACKET36. ROOF TAIL EXTENSION (3'-0" OVERHANG)37. ADHERED STONE38. E.P.S. TRIM BAND WITH SMOOTH STUCCO TEXTURE BELOW39. DECORATIVE 18" x 48" LOUVER AND STUCCO TRIM40. BUILT-UP COLUMN ACCENT41. SMOOTH STUCCO ACCENT WITH SCORING (24" X 24")42. SECTIONAL GARAGE DOOR WITH E.P.S. TRIM BANDS
00
GENERAL NOTES:01. COORDINATE LOCATION OF EXHAUST AND EXTERIOR MATERIAL AND
ARCHITECTURAL TRIMS.02. FIELD COORDINATE BALCONY DOOR AND WINDOWS TO BE CENTERED WITHIN
BALCONY SPACE. U.N.O.
NOTE:SEE SITE PLAN A1.01 FOR BUILDING NUMBERS AND LOCATION.BUILDING NUMBERS IN THE SHEET TITLE CORRELATE TOWHAT IS INDICATED ON THE SITE PLAN.
01. REFER TO CIVIL OR LANDSCAPE SITE PLAN FOR ACCESSIBLE SIDEWALK LAYOUT.
02. REFERENCE 300-SERIES DRAWINGS FOR UNIT PLANS, DIMENSIONS, INTERIORDOOR TYPES & SCHEDULES, ETC.
03. SEE SITE PLAN FOR LOCATION OF ACCESSIBLE UNITS.
04. SEE ROOF PLAN FOR LOW ROOF INFORMATION.
05. RATED WALLS AT STAIRS TO SECOND FLOOR ARE TO BE PRE-ROCKED PRIORTO THE INSTALLATION OF THE STAIRS.
06. PROVIDE 5/8" GYPSUM BOARD AT ONE SIDE OF WALL TO ALIGN WITH RATED WALL ATSTAIR TO SECOND FLOOR (SEE UNIT PLANS).
07. SEE A0.01 FOR WALL TYPES
GENERAL NOTES:
RCP LEGENDEXIT LIGHT
RECESSED CAN LIGHT
CEILING MOUNTED LIGHT
PENDANT - CEILING MOUNTED
FLORESCENT STRIP LIGHT
COMBINATION AUDIBLE /VISUAL DEVICE - FIRE ALARM
3 FIXTURE VANITY LIGHT - WALL MOUNTED
2 FIXTURE VANITY LIGHT - WALL MOUNTED
SINGLE FIXTURE- WALL MOUNTED
EXHAUST FAN
SQUARE RETURN DIFFUSER - CEILING MOUNTED
SUPPLY DIFFUSER - WALL MOUNTED
RETURN DIFFUSER - WALL MOUNTED
CEILING FAN
SQUARE SUPPLY DIFFUSER - CEILING MOUNTED
EXTERIOR CEILING MOUNTED LIGHT
5 FIXTURE VANITY LIGHT - WALL MOUNTED
ATTIC ACCESS PANEL
VENTILATION SCHEDULE
MF'GR & MODEL # FREE AREA
OFF RIDGE VENT
CLOACKED ATTIC VENT BY "O'HAGIN"
97.5 SQ.IN.= .67SQ. FT.
ROOF VENT
SOFFIT VENT @ EAVE VENTED "HARDISOFFIT" 5 SQ.IN./LINEAR FT.=.034 SQ. FT./LINEAR FT.
GROUND LEVEL0' - 0"
TRUSS BRG. 110' - 0"
08
01
6
12
6
12
37
08
03
39
7' -
0"
6' - 0"
0207
07
CL
GROUND LEVEL0' - 0"
TRUSS BRG. 110' - 0"
6
12
6
12
01
37
08
03
02
07
07
EQ EQ EQ
CJ CJ
CJ
14
15
GROUND LEVEL0' - 0"
TRUSS BRG. 110' - 0"
37
07
03
01
08
10
6
12
02
6" HIGH CURB
GROUND LEVEL0' - 0"
TRUSS BRG. 110' - 0"
37
08
01
03 1007
02
CJ
CJ CJ
14
01. PAINT ALL ROOF VENTS & PENETRATIONS TO MATCHROOF TILE COLOR.
02. PROVIDE AN OPENING IN THE MAIN ROOF SHEATHINGFOR VENTILATION AT OVER BUILD AREAS.
03. ATTIC VENTILATION HAS BEEN PROVIDED AT 1:300 PERSECTION 1203 OF THE FLORIDA BUILDING CODE, 2010EDITION. FREE AIR VENTILATION CALCULATIONS SHOWNARE BASED UPON THE LISTED MANUFACTURER'SSPECIFICATIONS.
04. CONTRACTOR TO COORDINATE ACTUAL VENTILATIONSPECIFICATIONS AND VERIFY ADHERENCE TO THEVENTILATION REQUIREMENTS STATED ABOVE.
05. ALL TILE ROOF SYSTEMS HAVE A HIGH TEMPERATUREICE AND WATER SHIELD ROOF UNDERLAYMENT.
GENERAL NOTES:
FIREWALL PARTITION TO UNDERSIDE OFROOF DECK.
NON-RATED ATTIC ACCESS PANEL,MIN. 22"X36". COORDINATE WITH ROOFTRUSSES & LIGHTING FIXTURES
OFF RIDGE VENT - MUSHROOM
DRYER VENT - ROOF MOUNTED
ROOF PIPE PENETRATION
INDICATES 36" SELF-ADHEREDMEMBRANE UNDER ROOF FELT
LEGEND:
1' -
6"
6 X 6 WOOD POST
EDGE OFSLAB/RAISED CURB
1' - 6"
1' -
6"
0' - 5 1/2"
7/8" STUCCO FINISH SYSTEM W/ MTL.LATH OVER ASPHALT FELT
STUCCO CORNER BEAD
WEATHER RESISTIVEBARRIER
E.P.S. TRIM BELOW
2X WOOD FRAMING
EXTERIOR SHEATHING
SELF ADHEREDMEMBRANE - WRAPCORNERS 6" MIN. EACHDIRECTION
ADHERED STONE BELOW
NOTE: OTHER SIDE SIMILAR
PLOTTED:
Drawn:
Checked:
Approval:
Date:
Project #:
2555 Temple Trail, Winter Park, FL 32789 (407) 629-0595www. fuglebergkoch.com AA26002103
REVISION HISTORY
ISSUE HISTORY
1 02/03/2015 ISSUE FOR PERMIT
No. Date Description
©
2012
These
docu
me
nts
and t
heir c
onte
nts
are
th
e p
ropert
y of
FU
GLE
BE
RG
KO
CH
, P
LLC
- A
A26002
103,
and a
re is
sued o
nly
for
the s
peci
fic p
roje
ct n
ote
d o
n t
hese
dra
win
gs.
Any
repro
du
ctio
ns,
revi
sio
ns,
or
modifi
catio
ns
of
these
docu
me
nts
with
out
the
exp
ress
ed w
ritt
en c
on
sent
of
Fugle
berg
Koch
, P
LLC
is p
roh
ibite
d b
y la
w.
B
A
C
D
E
F
G
H
B
A
C
D
E
F
G
H
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
KENNNETH LINEHANFLORIDA LICENSE# AR0017385
PE
RM
IT R
EV
IEW
ST
AM
P
PE
RM
IT R
EV
IEW
ST
AM
P
2/18/20155:31:34 PM
C:\Users\KyleP\Desktop\Revit Projects\5206-Estero - Apartments andAncillary_Kyle Paxton.rvt
Author
Checker
Approver
02/03/2015
5206
MAINTENANCEBUILDING
ESTERO, LEE COUNTY, FL
A9.55
COURTYARDS ATESTERO
No. Date Description
3/16" = 1'-0"F7MAINTENANCE - GROUND LEVEL
3/16" = 1'-0"C7MAINTENANCE RCP
3/16" = 1'-0"C3MAINTENANCE ROOF PLAN
3/16" = 1'-0"H4MAINTENANCE FRONT ELEVATION
3/16" = 1'-0"H8MAINTENANCE REAR ELEVATION
3/16" = 1'-0"F1MAINTENANCE RIGHT ELEVATION
3/16" = 1'-0"F4MAINTENANCE LEFT ELEVATION
ROOF VENT AREA SCHEDULE -MAINTENANCE
AREA NAMETOTAL
ROOF AREA
CODE ROOFVENT
FACTOR
TOTALVENTILATED
AREA
REQUIRED PROVIDED REQUIRED PROVIDED
CommentsVENTILATION AT
RIDGE (50%)VENTILATION
AT RIDGEVENTILATION AT
SOFFIT (50%)VENTILATION
AT SOFFIT
MAINTENANCE
MAINTENANCE 717 SF 0.0033 2.37 SF 1.18 SF 1.34 SF 1.18 SF 3.83 SF
1 1/2" = 1'-0"H1COLUMN DETAIL AT MAINT.
3MAINTENANCE AXON