Upload
vohanh
View
213
Download
0
Embed Size (px)
Citation preview
ASPEN HILL ROAD
Arterial
LA
N
D
G
R
E
E
N
S
T
R
E
E
T
LDG INC.L.3618 F.239
(PARCEL ONE)
"CONNECTICUT-ASPENSHOPPING CENTER"
PLAT NO. 8574
348
350
34234434
6
344
342
346344
342
340
338
342
346
348
350
352
336
334
332
330
350
348
346
344
326
328
330
VAN
EV PARKING
EV PARKING
MOTORCYCLE
D
A
M
WALL
WALL
PA
RK
IN
G
P
A
R
K
I
N
G
PA
RK
IN
G
8
346
344
350
346 348
344
350
348
346
346
346
344
344
342
MA
TC
HLIN
E (
SEE S
HEET
LT
-2)
PROFESSIONAL CERTIFICATION" I hereby certify that these documents were prepared or approved by me,and that I am a duly licensed professional Landscape Architect under the lawsof the State of Maryland, License No. 3894, Expiration Date: 04-22-2018"
N:\MD-Montgomery\Lindsay Ford\autocad\Plot Plans\Site Plan\LT-01-Lighting Plan.dwg
----
##
## LT-01
Lighting Plan
1245AMarch 2018AS SHOWN
3/20/2018 12:07 AM
SCALE
DRAWING NUMBER
DRAWING TITLE
DATE
PROJECT NUMBER
KEY PLAN
LINDS
AY FO
RD -
ASPE
N HI
LL
REVISIONS
NO DATE DESCRIPTION
ISSUEDATE DESCRIPTION
L I N D S A YFORD
FOR REVIEW
ONLY
SEAL & SIGNATURE
19847 Century Boulevard, Suite 200, Germantown, Maryland 20874Ph: 301.948.4700 (Main), Fx: 301.948.6256, www.rodgers.com
SIT
E PL
AN
#82
0180
070
HER
MIT
AG
E A
RT
/ C
ON
SOL
& P
AR
CEL
1B
CO
NN
ECT
ICU
T A
SPEN
HIL
LSH
OPP
ING
CEN
TER
AR
T /
CO
NSO
L (L
.361
8 F.
239)
Mont
gom
ery
Coun
ty E
lect
ion
Dis
tric
t (N
o.1
3) S
ilver
Spr
ing,
Mar
ylan
d
DESIGN TEAM
Applicant / Developer:
11250 Viers Mill Road, L.L.C.c/o Lindsay Automotive Group3410 King StreetAlexandria, Virginia 22302703.647.1276Attn: Michael Lindsay
Owner:
Lee Development Group, Inc.8601 Georgia AvenueSuite 200Silver Spring, Maryland 20910301-585-7000Attn: Bruce Lee
Legal:
Lerch, Early & Brewer, Chtd.7600 Wisconsin AvenueSuite 700Bethesda, Maryland 20814301.841.3829Attn: William Kominers
Architect:
Penney Design Group8200 Woodmont AvenueSuite 410Bethesda, Maryland 20814301-979-7600Attn: Jon Penney
Civil Engineering / Planning / Landscape Architecture:
Rodgers Consulting, Inc.19847 Century BoulevardSuite 200Germantown, Maryland 20878301.948.4700Attn: Robert Graham
Traffic Engineer:
Kimley-Horn11400 Commerce Park DriveSuite 400Reston, Virginia 20191703.674.1307Attn: Edward Papazian
Lighting Consultant:
LSILighting Services Inc2 Holt DriveStony Point, New York 10980845.942.2800Attn:
Preliminary Not For Construction
Developer's CertificateThe Undersigned agrees to execute all the features of the Site Plan Approval No. 820180070including Approval Conditions, Development Program, and Certified Site Plan.
Developer:
Address:
Phone:
Signature:
Company Contact Person
11250 Viers Mill Road L.L.C. - c/o Lindsay Automotive Group Michael Lindsay
3410 King Street, Alexandria, Virginia 22302
(703) - 647 - 1276
NOTE:
The Planimetric information shown on this plan is based in part on copyrighted GIS Data from M-NCPPC, and may not be copied or
reproduced without express written permission from M-NCPPC.
Planimetric/topographic maps compiled in part under our specifications generally depict planimetric features within 5 feet of their true
location. Contours will generally be depicted to within 2-1/2 feet of their true elevation, and spot elevations to within 1/2 foot of their
true elevation. Property maps reflect data from several sources and the accuracy varies accordingly. While each new subdivision is
mapped using survey coordinates shown on record plats, the majority of the data was digitized from tax maps, a source of which the
accuracy is impossible to quantify. Therefore, property line data in part should be interpreted as approximate.
10.26.2017 INITIAL PRE-SCREEN SUBMISSION02.28.2018 POST DRC SUBMISSION
Feet
1:360
120600
30
(513) 793-3200 * FAX (513) 793-6023
10000 ALLIANCE RD. CINCINNATI, OHIO 45242 USA
GENERAL NOTES:
1. Based on the information provided, all dimensions and luminaire locationsshown represent recommended positions. The engineer and/or architect must
determine the applicability of the layout to existing or future field conditions.
2. This lighting plan represents illumination levels calculated from laboratory datataken under controlled conditions in accordance with The Illuminating
Engineering Society (IES) approved methods. Actual performance of any
manufacturer's luminaires may vary due to changes in electrical voltage,tolerance in lamps/LED's and other variable field conditions. Calculations donot include obstructions such as buildings, curbs, landscaping, or any otherarchitectural elements unless noted. Fixture nomenclature noted does not
include mounting hardware or poles. This drawing is for photometricevaluation purposes only and should not be used as a construction documentor as a final document for ordering product.
PLAN PREPARED BY:
C
D
B
A
E
F
LEGEND
LIGHT FIXTURE A (SEE LT-03)
LIGHT FIXTURE B (SEE LT-03)
LIGHT FIXTURE C (SEE LT-03)
LIGHT FIXTURE D (SEE LT-03)
LIGHT FIXTURE E (SEE LT-03)
LIGHT FIXTURE F (SEE LT-03)