2 General 3 The range of K10 cam switches (10 A rating) comprises only complete switches. These products are more specifically designed for process control applications: compact size, easy to integrate with other Ø 16 and Ø 22 mm units, selection functions. b b b Complete switches Front mounting switches stepping switches reversing switch changeover switches voltmeter switches ammeter switches b b b b b b By Ø 16.3 or Ø 22.3 mm hole Mounting Ø 16 or Ø 22 hole fixing Locking/unlocking of the body-head assembly by spigot Ø 16 hole fixing Ø 22 hole fixing 1 2 0 1 2 0 2 0 3 1 2 0 3 1 1 2 0 1 2 0 Characteristics: page 30051-EN/3 References: page 30051-EN/4 Dimensions: page 30051-EN/9 Characteristics: page 30051-EN/3 References: page 30051-EN/4 Dimensions: page 30051-EN/9 Cam switches 3 Complete switches, 10 A 30051-EN_Ver6.1.indd

General Cam switches Complete switches, 10 Adocs-europe.electrocomponents.com/webdocs/0e64/0900766b...2 General 3 The range of K10 cam switches (10 A rating) comprises only complete

  • Upload
    dohanh

  • View
    231

  • Download
    5

Embed Size (px)

Citation preview

2

General 3

The range of K10 cam switches (10 A rating) comprises only complete switches.These products are more specifi cally designed for process control applications:

compact size, easy to integrate with other Ø 16 and Ø 22 mm units, selection functions.

bbb

Complete switches Front mounting

switchesstepping switchesreversing switchchangeover switchesvoltmeter switchesammeter switches

bbbbbb

By Ø 16.3 or Ø 22.3 mm hole

Mounting Ø 16 or Ø 22 hole fi xing

Locking/unlocking of the body-head assembly by spigot

Ø 16 hole fi xing Ø 22 hole fi xing

1

20

1

20

2

0

3

1

2

0

3

1

1

20

1

20

Characteristics:page 30051-EN/3

References:page 30051-EN/4

Dimensions:page 30051-EN/9

Characteristics:page 30051-EN/3

References:page 30051-EN/4

Dimensions:page 30051-EN/9

Cam switches 3 Complete switches, 10 A

30051-EN_Ver6.1.indd

3

Characteristics 3

EnvironmentConformity to standards EN/IEC 60947-3

EN/IEC 60947-5-1UL 508

Product certifi cations cULus

Protective treatment Standard version: “TC”

Ambient air temperature For operation: - 20…+ 55 °C

For storage: - 40…+ 70 °C

Electric shock protection Class II, conforming to IEC 61140

Degree of protection IP 65 conforming to IEC 60529 (operating head)IP 20 (contact block)

Mechanical life 1 million operating cycles

Contact block characteristicsRated operational characteristics AC-15, A300 – 240 V 3 A

120 V 6 AAC-21A, AC-1 – 400 V 10 AUL/CanadaHeavy DutyA300

3-phase 110/120 V 0.75 hp220/240 V 1 hp

single-phase 110/120 V 0.33 hp220/240 V 0.75 hp

AC-23A 3-phase 220/240 V 1.8 kWsingle-phase 110/120 V 0.37 kW

220/240 V 0.75 kWd.c. current Ieresistive load

1 contact 24 V 10 A110 V 0.7 A220 V 0.3 A

Short-circuit protection 10 A cartridge fuse type gG

Conventional thermal current (Ith) 10 A

Rated insulation voltage (Ui) 440 V, degree of pollution 3, conforming to IEC 60947-1

Contact operation Slow break

Terminal referencing Conforming to EN 50013

Rated impulse withstand voltage (U imp) 4 kV conforming to IEC 60947-1

Electrical reliability Failure rate < 1 fault for 100 million operating cycles (c 24 V PLC inputs)

Connection Captive screw clamp terminalsClamping capacity: 2 x 1.5 mm2

General:page 30051-EN/2

References:page 30051-EN/4

Dimensions: page 30051-EN/9

General:page 30051-EN/2

References:page 30051-EN/4

Dimensions: page 30051-EN/9

Cam switches 3 Complete switches, 10 AFront mounting by Ø 16 or Ø 22 mm holeWith 30 x 30 mm front plate

30051-EN_Ver6.1.indd

4

References 3

Switches with 60° switching angleWiring diagramandswitching programme

Markingand switchposition

Numberof poles

Reference Weight

kg

1 K10 A001ACH 0.030

2 K10 B002ACH 0.035

3 K10 C003ACH 0.045

4 K10 D004ACH 0.045

Stepping switches, single-pole, with “0” positionWiring diagramandswitching programme

Markingand switchposition

Numberof steps

Reference Weight

kg

2 + “0” K10 B002QCH 0.035position

3 + “0” K10 C003QCH 0.045position

4 + “0” K10 D004QCH 0.045position

78

56

34

12

1 2 3 4

012345678

601-pole2-pole3-pole4-pole

78

56

34

12

1 2 3 4

012345678

601-pole2-pole3-pole4-pole

01

060

01

060

K10 B002ACH

5525

7

K10 B002ACH

5525

7

33012

30

34

270

12

L1

34

1 2

33012

30

34

270

12

L1

34

1 2

1

0

2

270

30330

1

0

2

270

30330

12

L1

34

1 2

56

3

31512

0

34

1

34

270 45

56

12

L1

34

1 2

56

3

31512

0

34

1

34

270 45

56

12

30

0315 45

270

12

30

0315 45

270

78

56

34

1 2 3 4

21

L1

3012

330300270

34

1234

0

5678

78

56

34

1 2 3 4

21

L1

3012

330300270

34

1234

0

5678

0 30330300270

42 310

0 30330300270

42 310

K10 D004QCH

5502

58

K10 D004QCH

5502

58

General:page 30051-EN/2

Characteristics: page 30051-EN/3

Dimensions:page 30051-EN/9

General:page 30051-EN/2

Characteristics: page 30051-EN/3

Dimensions:page 30051-EN/9

Cam switches 3 Complete switches, 10 AFront mounting by Ø 16 or Ø 22 mm holeWith 30 x 30 mm front plate

30051-EN_Ver6.1.indd

5

References (continued) 3

Stepping switches, 2-pole, with “0” positionWiring diagramandswitching programme

Markingand switchposition

Numberof steps

Reference Weight

kg

2 + “0” K10 D012QCH 0.045position

3 + “0” K10 F013QCH 0.055position

Stepping switches, single-pole, without “0” position

3 K10 C003NCH 0.045

4 K10 D004NCH 0.045

12

L1

34

1

5678

L2

2330

12

30

34

1234

270

5678

12

L1

34

1

5678

L2

2330

12

30

34

1234

270

5678

1

0

2

270

30330

1

0

2

270

30330

5502

59

K10 D012QCH

5502

59

K10 D012QCH

1

12

L1

345678

L2

9101112

2 3

31512

0

34

1234

270

5678

45

9101112

1

12

L1

345678

L2

9101112

2 3

31512

0

34

1234

270

5678

45

9101112

12

30

0315 45

270

12

30

0315 45

270

12

L1

34

1 2

56

3330

12

30

34

1234

270

56

12

L1

34

1 2

56

3330

12

30

34

1234

270

56

2

1

3

270

30330

2

1

3

270

30330

12

L1

34

1 2

56

3

78

4

33012

30

34

1234

270

56

90

78

12

L1

34

1 2

56

3

78

4

33012

30

34

1234

270

56

90

78

32

41

30330

90270

32

41

30330

90270

General:page 30051-EN/2

Characteristics:page 30051-EN/3

Dimensions:page 30051-EN/9

General:page 30051-EN/2

Characteristics:page 30051-EN/3

Dimensions:page 30051-EN/9

General:page 30051-EN/2

Characteristics:page 30051-EN/3

Dimensions:page 30051-EN/9

General:page 30051-EN/2

Characteristics:page 30051-EN/3

Dimensions:page 30051-EN/9

Cam switches 3 Complete switches, 10 AFront mounting by Ø 16 or Ø 22 mm holeWith 30 x 30 mm front plate

30051-EN_Ver6.1.indd

6

References (continued) 3

Stepping switch, 2-pole, without “0” positionWiring diagramandswitching programme

Markingand switchposition

Numberof steps

Reference Weight

kg

3 K10 F013NCH 0.055

Changeover switch with spring return to “0” positionWiring diagramandswitching programme

Markingand switchposition

Numberof poles

Reference Weight

kg

1 K10 B006TCH 0.035

270

30330

2

1

3

270

30330

2

1

3

1

12

L1

345678

L2

9101112 2 3

33012

30

34

1234

270

56789101112

1

12

L1

345678

L2

9101112 2 3

33012

30

34

1234

270

56789101112

12

L1

1 2

L4

34

012

30

34

330

12

L1

1 2

L4

34

012

30

34

330

21 0

0330 30

21 0

0330 30

5502

60

K10 B006TCH

5502

60

K10 B006TCH

General:page 30051-EN/2

Characteristics:page 30051-EN/3

Dimensions: page 30051-EN/9

General:page 30051-EN/2

Characteristics:page 30051-EN/3

Dimensions: page 30051-EN/9

Cam switches 3 Complete switches, 10 AFront mounting by Ø 16 or Ø 22 mm holeWith 30 x 30 mm front plate

30051-EN_Ver6.1.indd

7

References (continued) 3

Changeover switches with “0” positionWiring diagramandswitching programme

Markingand switchposition

Numberof poles

Reference Weight

kg

1 K10 B001UCH 0.035

2 K10 D002UCH 0.045

3 K10 F003UCH 0.055

4 K10 H004UCH 0.065

Changeover switches without “0” position

1 K10 B011UCH 0.035

2 K10 D012UCH 0.045

3 K10 F013UCH 0.055

4 K10 H014UCH 0.065

12345678910111213141516 1 2

L/1 2 3 4

012

60

34

300

5678910111213141516

1-pole

2-pole

3-pole

4-pole

12345678910111213141516 1 2

L/1 2 3 4

012

60

34

300

5678910111213141516

1-pole

2-pole

3-pole

4-pole

1 20

060300

1 20

060300

K10 F003UCH

5502

61

K10 F003UCH

5502

61

12345678910111213141516 1 2

L/1 2 3 4

301234

330

5678910111213141516

1-pole

2-pole

3-pole

4-pole

12345678910111213141516 1 2

L/1 2 3 4

301234

330

5678910111213141516

1-pole

2-pole

3-pole

4-pole

21 21

General:page 30051-EN/2

Characteristics:page 30051-EN/3

Dimensions: page 30051-EN/9

General:page 30051-EN/2

Characteristics:page 30051-EN/3

Dimensions: page 30051-EN/9

Cam switches 3 Complete switches, 10 AFront mounting by Ø 16 or Ø 22 mm holeWith 30 x 30 mm front plate

30330

30051-EN_Ver6.0.indd

8

References (continued) 3

Voltmeter switchesFor measurements between 3 phases and between 1 phase and neutralWiring diagramandswitching programme

Markingand switchposition

Reference Weight

kg

K10 F027MCH 0.055

For measurements between 3 phases, with “0” position

K10 D024MCH 0.045

Ammeter switchesFor 3 circuits, with “0” position

K10 F003MCH 0.055

30012

330

34

270 0 30 60 90

56789101112

12

L1

345678

L3

9101112

L2 N

V

30012

330

34

270 0 30 60 90

56789101112

12

L1

345678

L3

9101112

L2 N

V

L1-L2 0 L1-NL2-L3L3-L1

L2-NL3-N

045315

135225

270 90

L1-L2 0 L1-NL2-L3L3-L1

L2-NL3-N

045315

135225

270 90

5502

62

K10 F027MCH

5502

62

K10 F027MCH

12

L1

345678

L3L2

V

31512

0

34

270 45

5678

12

L1

345678

L3L2

V

31512

0

34

270 45

5678

L2-L3L3-L1L1-L2

0

045315

270

L2-L3L3-L1L1-L2

0

045315

270

123456789101112

PEL3L2L1

A

9012

180

34

0 270

56789101112

123456789101112

PEL3L2L1

A

9012

180

34

0 270

56789101112

0

2

3 1

270 90

0

180

0

2

3 1

270 90

0

180

5502

63

K10 F003MCH

5502

63

K10 F003MCH

General:page 30051-EN/2

Characteristics:page 30051-EN/3

Dimensions:page 30051-EN/9

General:page 30051-EN/2

Characteristics:page 30051-EN/3

Dimensions:page 30051-EN/9

Cam switches 3 Complete switches, 10 AFront mounting by Ø 16 or Ø 22 mm holeWith 30 x 30 mm front plate

30051-EN_Ver6.1.indd

9

Dimensions 3

Cam switches, 10 A

aK10 A, B 51K10 C, D 63K10 F 75K10 H 87

e: support panel thickness 0.5 to 5 mm.

Ø 16 and Ø 22 mm panel cut-outs

Convention used for switching programme representationLink positions (factory mounted)

Angular position of switch

Graphic representation of switching positions and spring return to “0” position

25 e

a

30 2825 e

a

30 28

16,2

1,7

9,8

22,3

3,2

12,7

16,2

1,7

9,8

22,3

3,2

12,7

123456

L3L2L1

78910

WVU

123456

L3L2L1

78910

WVU

045315

045315

1234

450

5678

315

910 Contact terminal reference number

Contact closed

Contact closed in 2 positions and maintained between the 2 positions

Sealed assembly for auto-maintain control

Overlapping contacts

1234

450

5678

315

910 Contact terminal reference number

Contact closed

Contact closed in 2 positions and maintained between the 2 positions

Sealed assembly for auto-maintain control

Overlapping contacts

General: page 30051-EN/2

Characteristics:page 30051-EN/3

References: pages 30051-EN/4 to 30051-EN/8

General: page 30051-EN/2

Characteristics:page 30051-EN/3

References: pages 30051-EN/4 to 30051-EN/8

General: page 30051-EN/2

Characteristics:page 30051-EN/3

References: pages 30051-EN/4 to 30051-EN/8

General: page 30051-EN/2

Characteristics:page 30051-EN/3

References: pages 30051-EN/4 to 30051-EN/8

Cam switches 3 Complete switches, 10 AFront mounting by Ø 16 or Ø 22 mm holeWith 30 x 30 mm front plate

30051-EN_Ver6.1.indd