GEM Foil Stretching GEM Foil Stretching Using a Using a Low-Cost Infrared Low-Cost Infrared Heating Array Heating Array Elizabeth Esposito Erik Maki Undergraduate Research Florida Institute of Technology, HEP Lab A FAS Annual Conference, March 2012

GEM Foil Stretching Using a Low-Cost Infrared Heating Array GEM Foil Stretching Using a Low-Cost Infrared Heating Array Elizabeth Esposito Erik Maki Undergraduate

Embed Size (px)

Citation preview

Page 1: GEM Foil Stretching Using a Low-Cost Infrared Heating Array GEM Foil Stretching Using a Low-Cost Infrared Heating Array Elizabeth Esposito Erik Maki Undergraduate

GEM Foil Stretching Using GEM Foil Stretching Using a a Low-Cost Infrared Heating Low-Cost Infrared Heating ArrayArray

Elizabeth EspositoErik Maki

Undergraduate ResearchFlorida Institute of Technology, HEP Lab AFAS Annual Conference, March 2012

Page 2: GEM Foil Stretching Using a Low-Cost Infrared Heating Array GEM Foil Stretching Using a Low-Cost Infrared Heating Array Elizabeth Esposito Erik Maki Undergraduate

OverviewOverviewPurpose / BackgroundPrevious workImprovements to previous workResultsConclusionsFuture plans

Page 3: GEM Foil Stretching Using a Low-Cost Infrared Heating Array GEM Foil Stretching Using a Low-Cost Infrared Heating Array Elizabeth Esposito Erik Maki Undergraduate

PurposePurposeDesign a cost-effective, readily-

implemented method of stretching GEM (gas electron multiplier) foils, improving upon previous designs.

100cm x 50cm GEM foils stretched with this method will be used to upgrade the muon tomography station of Florida Institute of Technology’s High Energy Physics Lab A.

Page 4: GEM Foil Stretching Using a Low-Cost Infrared Heating Array GEM Foil Stretching Using a Low-Cost Infrared Heating Array Elizabeth Esposito Erik Maki Undergraduate

Why Stretch GEM Foils?Why Stretch GEM Foils? GEM foils are a

crucial component of detectors such as the triple GEM detector on the left.

In order to be useable, they must be uniform.

This uniformity is obtained through stretching, usually in a clean room oven.

Page 5: GEM Foil Stretching Using a Low-Cost Infrared Heating Array GEM Foil Stretching Using a Low-Cost Infrared Heating Array Elizabeth Esposito Erik Maki Undergraduate

Muon Tomography Station Muon Tomography Station (MTS)(MTS)

• Two 30cm x 30cm GEM detectors were built for Florida Tech’s muon tomography station using the following method.

Below: Imaging area seen with two blocks of high-Z material.

[GEM Detectors]

Page 6: GEM Foil Stretching Using a Low-Cost Infrared Heating Array GEM Foil Stretching Using a Low-Cost Infrared Heating Array Elizabeth Esposito Erik Maki Undergraduate

Previous WorkPrevious Work• Designed to stretch 100cm x 50cm GEM foils –

scaled-up from 30cm x

30cm design – as cost-efficiently

as possible using locally-

sourced materials.

• Aluminum frame supports eight/sixteen 250W infrared heat lamps.

• Used to stretch foils at 45°C - 50°C.

Page 7: GEM Foil Stretching Using a Low-Cost Infrared Heating Array GEM Foil Stretching Using a Low-Cost Infrared Heating Array Elizabeth Esposito Erik Maki Undergraduate

Why 35°C?Why 35°C?

The above GEM foil was stretched at 50°C. Note the ridging of the spacer ribs! Lower temperatures minimize / eliminate this! (CERN stretches at 37°C).

Page 8: GEM Foil Stretching Using a Low-Cost Infrared Heating Array GEM Foil Stretching Using a Low-Cost Infrared Heating Array Elizabeth Esposito Erik Maki Undergraduate

Current DesignCurrent Design

Credit: Elizabeth Esposito, 2011

• 1”-diameter aluminum rods support the frame – allows for greater versatility and mobility. Several stations can easily be set up on the same optical table.

• Sixteen 125W heat lamps were used in place of the previous 250W bulbs.

• Used to stretch foils at 35°C.

Page 9: GEM Foil Stretching Using a Low-Cost Infrared Heating Array GEM Foil Stretching Using a Low-Cost Infrared Heating Array Elizabeth Esposito Erik Maki Undergraduate

ResultsResults

Nu

mb

er

of

tem

pera

ture

measu

rem

en

ts

per

bin

Mean: 35.12°C RMS: 0.1669

Page 10: GEM Foil Stretching Using a Low-Cost Infrared Heating Array GEM Foil Stretching Using a Low-Cost Infrared Heating Array Elizabeth Esposito Erik Maki Undergraduate

Top: Current results, 125 W

bulbs

RMS: 0.1669

Bottom: Previous results,

250 W bulbs

RMS: 1.367

Num

ber

of

tem

pera

ture

measu

rem

en

ts p

er

bin

Num

ber

of

tem

pera

ture

measu

rem

en

ts p

er

bin

Page 11: GEM Foil Stretching Using a Low-Cost Infrared Heating Array GEM Foil Stretching Using a Low-Cost Infrared Heating Array Elizabeth Esposito Erik Maki Undergraduate

ResultsResults

Long-Term Temperature Variation

Stable plateau reached at ~3 hours

Optical Table

[Location key]

Page 12: GEM Foil Stretching Using a Low-Cost Infrared Heating Array GEM Foil Stretching Using a Low-Cost Infrared Heating Array Elizabeth Esposito Erik Maki Undergraduate

Top: Unstretched 100 x 50cm …….GEM foil at ~25°C.

Bottom: Stretched 100 x 50 cm

GEM foil at 35°C.

Note the reflection of the light bulbs in the foil!

Page 13: GEM Foil Stretching Using a Low-Cost Infrared Heating Array GEM Foil Stretching Using a Low-Cost Infrared Heating Array Elizabeth Esposito Erik Maki Undergraduate

ConclusionsConclusions125 W light bulbs provided a very

uniform temperature of ~35°C. Temperature variations were minimal and did not affect the operation of the array.

Current results: RMS: 0.1669 compared w/ previous results: RMS:1.367.

Foils stretched using this method appeared to be uniformly stretched.

Page 14: GEM Foil Stretching Using a Low-Cost Infrared Heating Array GEM Foil Stretching Using a Low-Cost Infrared Heating Array Elizabeth Esposito Erik Maki Undergraduate

Future PlansFuture Plans

Improve the methodsof temperature control.

Build multiple arrays for more efficient detector construction.

Use the array to stretch 100cm x 50cm GEM foils for use in upgrading Florida Institute of Technology’s muon tomography station.

Page 15: GEM Foil Stretching Using a Low-Cost Infrared Heating Array GEM Foil Stretching Using a Low-Cost Infrared Heating Array Elizabeth Esposito Erik Maki Undergraduate

AcknowledgementsAcknowledgements

Research advisor: Dr. Marcus Hohlmann

Previous work: Michael Staib

Bryant BensonKondo Gnanvo