11
GELLO 1.1 Update GELLO v1 update ballot Andrew McIntyre Medical-Objects Australia

GELLO 1.1 Update GELLO v1 update ballot Andrew McIntyre Medical-Objects Australia

Embed Size (px)

Citation preview

Page 1: GELLO 1.1 Update GELLO v1 update ballot Andrew McIntyre Medical-Objects Australia

GELLO 1.1 Update

GELLO v1 update ballotAndrew McIntyreMedical-Objects

Australia

Page 2: GELLO 1.1 Update GELLO v1 update ballot Andrew McIntyre Medical-Objects Australia

GELLO 1.1

Existing Standard has errors BNF broken Some Examples incorrect Missing Information Requires update for interoperability New BNF has been developed

Supports almost all existing Examples Minimal change to Normative Text

Similar to OCL 2.0 (with extensions and deletions)

Page 3: GELLO 1.1 Update GELLO v1 update ballot Andrew McIntyre Medical-Objects Australia

GELLO

Background Grew out of GLIF development “Guideline execution language Object

Orientated” Can be used instead of curly braces in Arden Can be used stand alone Cannot change EHR, safe to execute

Lacks ability to perform dangerous operations

Page 4: GELLO 1.1 Update GELLO v1 update ballot Andrew McIntyre Medical-Objects Australia

GELLO Examples

Page 5: GELLO 1.1 Update GELLO v1 update ballot Andrew McIntyre Medical-Objects Australia

Real GELLO

Page 6: GELLO 1.1 Update GELLO v1 update ballot Andrew McIntyre Medical-Objects Australia

Real GELLO returns values

Page 7: GELLO 1.1 Update GELLO v1 update ballot Andrew McIntyre Medical-Objects Australia

Terminology Support

Page 8: GELLO 1.1 Update GELLO v1 update ballot Andrew McIntyre Medical-Objects Australia

CTS Access

Page 9: GELLO 1.1 Update GELLO v1 update ballot Andrew McIntyre Medical-Objects Australia

GELLO needs vMR

“Virtual Medical Record” Simplified view of the RIM Not specified by GELLO standard

Page 10: GELLO 1.1 Update GELLO v1 update ballot Andrew McIntyre Medical-Objects Australia

Many possible uses

Data access for ARDEN syntax Criterion specification Message validation Calculated values Visibility/validation in editors GLIF/Other Guidelines Assessments and scales

Eg CDAI, eGFR, GCS

Page 11: GELLO 1.1 Update GELLO v1 update ballot Andrew McIntyre Medical-Objects Australia

Further Work

Interface to vMR is loose currently Needs to be well described for compiler Compiler can read from idl or HL7 “ocl”

Implementation of vMR Can be implemented with services Can be implemented with direct access

Database Messages (eg CCD/Query)

Subject of further independent work