4
1 GECOL Cril piscinas Technical data sheet _ 18/06/18 GECOL Cril piscinas Single-component acrylic coating for swimming pools High resistance and washability. Resistant to weathering and alkalinity. Excellent filling power, covering and waterproofing. Great flexibility, hardness and adhesion. Appearance and silky touch. Avoid the proliferation of algae. Fast drying It allows an unlimited repainting. Minimum retraction in its drying. Solvent free. Resistant to UV rays. Uses Quality Effect Anti-mould

GECOL Cril piscinas · GECOL Cril piscinas Technical data sheet _ 18/06/18 2 ·Do not apply if there is a risk of frost, with direct sunlight, strong wind or rain. ·To ensure color

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GECOL Cril piscinas · GECOL Cril piscinas Technical data sheet _ 18/06/18 2 ·Do not apply if there is a risk of frost, with direct sunlight, strong wind or rain. ·To ensure color

1GECOL Cril piscinas Technical data sheet _ 18/06/18

GECOL Cril piscinasSingle-component acrylic coating forswimming pools

High resistance and washability.

Resistant to weathering and alkalinity.

Excellent filling power, covering and waterproofing.

Great flexibility, hardness and adhesion.

Appearance and silky touch.

Avoid the proliferation of algae.

Fast drying It allows an unlimited repainting.

Minimum retraction in its drying.

Solvent free.

Resistant to UV rays.

Uses Quality

EffectAnti-mould

Page 2: GECOL Cril piscinas · GECOL Cril piscinas Technical data sheet _ 18/06/18 2 ·Do not apply if there is a risk of frost, with direct sunlight, strong wind or rain. ·To ensure color

2GECOL Cril piscinas Technical data sheet _ 18/06/18

Do not apply if there is a risk of frost, with direct·sunlight, strong wind or rain.

To ensure color uniformity, we recommend ordering·the total amount of the product necessary at thesame time.

In any case, do not mix or alternate different·manufacturing lots in the same section.

Protect the area around the application surface,·using water to clean any possible splashed product,always before it hardens.

Use the correct adhesive tape to mark off working·sections or intentional cuts for decoration on thefaçade.

Avoid excessive thicknesses.·

If in doubt, always consult our Technical Department.·

Water based acrylic paint, monocomponent, suitablefor protection, waterproofing and rehabilitation inponds, artificial lakes, tanks and pools of cement andconcrete.

Resistant to molds, algae, alkalis and diluted acids.

Areas of application

Directions for use

1_Before getting started

Page 3: GECOL Cril piscinas · GECOL Cril piscinas Technical data sheet _ 18/06/18 2 ·Do not apply if there is a risk of frost, with direct sunlight, strong wind or rain. ·To ensure color

3GECOL Cril piscinas Technical data sheet _ 18/06/18

As a general rule, all substrates must be: sturdy, free·of dust and grease, stable, rough, flat, with somedegree of moisture and absorption and totally set-up(hardened).

Poorly bonded rendering or rough rendering and·voids or cracks should be eliminated.

In the event of nitrate efflorescence, this must be·removed by brushing the surface when dry andtreated with GECOL Desincrustante, followed bythorough rinsing.

Substrate types and conditions:·

A. Cement mortar substrate: Solid and clean with excellent resistance with allmortar shrinkage complete.When applying via mechanical projection, wetdown several times two days afterwards toprevent drying out. Apply a floated finish in all cases.

B. Concrete substrate:Solid and clean with excellent resistance with allconcrete shrinkage complete.Prevent all surface grout and/or release agents bycleaning mechanically or washing with GECOL Desincrustante.Rinse with clean water and let dry.

C. Painting support:On badly adhering paints or paints, removecompletely and proceed according to the support.Paints in good condition, sand lightly with finegrain sandpaper, completely eliminating thegenerated dust.

Prior to using it, shake package contents·mechanically until fully mixed.

Apply with a brush, roller or spray gun, in the·traditional method.

For application using a spray gun, dilute in 5-10%·water.

For application using a brush or roller, apply a primer·coat diluted in 15-20 % water.

After 4-5 hours have elapsed, apply a second coat·with a maximum dilution of 5% water.

2_Substrate preparation

3_Application

Page 4: GECOL Cril piscinas · GECOL Cril piscinas Technical data sheet _ 18/06/18 2 ·Do not apply if there is a risk of frost, with direct sunlight, strong wind or rain. ·To ensure color

4GECOL Cril piscinas Technical data sheet _ 18/06/18

Over substrates with more than 5% residual moisture.· Any residue on tools and coated surfaces must becleaned with water before the product hardens.

Twenty-four months from date of manufacture in a sealed package and protected from the weather

Dry to touch time: 30 – 60 minutes (20 °C)

Waiting time between coats: at least 8 hours (20 °C; this may be longer at low temperatures or shorter at high temperatures)

Swimming-pool refill: After 8 - 15 days (depending on weather conditions)

Application temperature: from +5 °C to +35 °C (measured on the substrate)

Wet scrub resistance: Type II (UNE 48243)

VOC content: < 140 g / l

Reaction to fire: B-s1; d0

Application

Ultimate performance

Storage

Theoretical yield: 5.5 – 7 kg / m2 (per surface layer)

6 and 20 kg containers

Colours: White and blue

Composition: synthetic resins, loads, organic and inorganic additivesand mineral pigments

Thinner: Water

Density: 1.42 +/- 0.1 g / cm3

Solids in weight: 62 + / - 2 %

Coverage

Supply

Product

CleaningLimits of use

Hazard

H317 May cause an allergic skinreaction.

Precautionary

P101 If medical advice is needed, havecontainer or label.

P102 Keep out of reach of children.

P103 Read label before use.

P260 Do not breathe vapor / sprayproduct.

P285 In case of inadequate ventilationwear respiratory protection equipment.

P302 + P350 IF ON SKIN: Gently washwith plenty of soap and water.

P301 + P330 + P331 IF SWALLOWED:Rinse mouth. Do not induce vomiting.

P312: Call a poison control center orphysician if you feel unwell.

GHS07

P501 Dispose of contents and containerin accordance with nationalregulations.

VOC directive 2004/42 (II). Categories A/iEU limit value for product: 140 g/l (2010)Maximum VOC content of thisproduct: 120 g/l

Safety data

DANGER

Prior to the use of this adhesive, we recommend consulting the instruction manual.The information provided in this technical documentation has been obtained understandard laboratory conditions, and so may vary depending on the on-siteinstallation and on the specific weather conditions, which are beyond our control.

GECOL guarantees that their auxiliary products will perform flawlessly in thesituations listed. Materials from other brands or situations other than thosedescribed can affect the physical and aesthetic properties of our products.