18
GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior permission of the copyright owner.

GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior

Embed Size (px)

Citation preview

Page 1: GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior

GECritical Power

© 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior permission of the copyright owner.

Page 2: GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior

The grid as we know it was originally designed with 2 applications in mind:

The electric motor &

The light bulb

Page 3: GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior

The power delivered by the grid is not sufficiently reliable and clean for the Digital World of today.

Page 4: GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior

Power Disturbances, Cause & Effect

Noise Frequency Variation

OutagesHarmonics

Spikes

Sags

Swells

Causes

Breakdown

Nature and weather

Interference by Human

Effects

Lost Revenue

Lost Productivity

Equipment damage

Safety

Sags / Brown out

Page 5: GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior

5

GE Critical Power

End-to-end power solutions for the building, box and board

Power Switching

Uninterruptible Power Supplies

DC Power Systems

Embedded Power

Automatic Transfer Switches

Surge Protective Devices

Paralleling Switchgear

48Vdc Power Plant Systems, 3,000-20,000A

Line Power Panels

DC Distribution, BDFBs

Three Phase UPS, 10-750kVA

Single Phase UPS, 1-10kVA

Global Services

AC-DC Rectifiers & Power Supplies

DC-DC Isolated Converters

DC-DC Point of Load (POLs)

Page 6: GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior

Enhancing System Reliability for the World’s Most Critical Processes

Page 7: GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior

ATS/PSG COEChicago, USA

UPS COERiazzino, Switzerland

Facility Locations relevant to MEA Region

Page 7

Page 8: GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior

Products

Page 9: GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior

Uninterruptible Power Supplies — UPS

Applications:• Desktop PC’s,

workstations, small servers, switchboards, routers, switches, etc

• 1 – 2 – 3 kVA

• Cost effective

Applications:• Small/medium

servers, dense power rack applications, security systems

• 6 and 10kVA

• Flexible in use (tower/rack)

Applications:• Networks, computer

rooms, cable networks, security systems, medium office, call center etc.

• 3–5–6–8–10–15-20 kVA

• Critical applications

Applications:

• desktop PC’s, cash registers, fax machine, ISDN/ADSLA adapters, etc.

• 400-600-800-1000-1500VA

VCO series

Double conversion

GT seriesDouble conversion

LP seriesDouble conversion

VCL seriesLine interactive

Page 10: GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior

Uninterruptible Power Supplies — UPS

Applications:

• Computer rooms, small datacenters, security systems, networks.

• 10, 20, 30, 40, 60, 80, 100, 120 kVA

• Smal footprint• Input power factor correction• Graphic display• Static and manual bypass• Cost effective

Applications:

• Industrial, telecom, manufacturing processes, complete site protection, medical applications

• 10, 20, 30, 40, 60, 80, 100, 120, 160, 200, 250, 300, 400, 500, 600 kVA

• Very low input current harmonic distortion (THDI <2%)

• High output power factor 0.9 leading and lagging

• High efficiency• Long backup time• Graphic display

SG PurePulse serieswith inverter transformer

LP seriestransformerless

TLE seriesTransformerless

Applications:

• Datacenters, call centers, IT infrostructure

• 160, 200, 320, 400, 600, 800 kW

• Very low input current harmonic distortion (THDI <2%)

• Output power factor 1• Very High efficiency• Full colour Graphic display

Page 11: GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior

ZTX Series ZTG Series ZTS Series ZTE Series

Applications:• Small Frame

Commercial and Light Industrial

• Standard Transition

• 40-400 Amp, 120-480 Volt ratings

Applications:

• General purpose Commercial and Industrial

• Standard & Delayed Transition

• 40-3000 Amp & 120-600 Volt ratings

Applications:• Business Critical

Applications

• Standard, Delayed, Closed Transition

• Bypass versions available with all Transition modes

• 40-4000 Amp ratings 120-600 Volt ratings

Applications:• Life Safety & Mission

Critical Applications

• PQ metering, Enhanced Diagnostics & Connectivity,

• Standard, Delayed, Closed Transition & Bypass

• 40-4000 Amp, 120-600 Volt ratings

Zenith Automatic Transfer Switches -ATSGTX Series

Applications:

• Small Frame Commercial and Light Industrial

• Standard Transition

• 100-400 Amp, 380/416 Volt ratings

Page 12: GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior

Technology Highlights

Page 13: GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior

Increasing focus on Cost of Ownership

Increasing power density (W/sqm)

Increasing criticality

High efficiency

Driving need for smaller, more reliable and more efficient Power Quality equipment

Page 14: GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior

Chloride 80 NET300 kVA

Powerware 9395275 kVA

MGE 7000160 kVA

Agenda

GE SG PP S3300 kVA

GE SG PP S3160 kVA

GE TLE200 kW

GE TLE400 kW

94.294.294.293.093.8 96.2 96.5

Best in Class efficiency @50%, p.f.=1

Trends: Increase Efficiency

Page 15: GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior

Chloride 80 NET300 kVA

Powerware 9395275 kVA

MGE 7000160 kVA

Agenda

GE SG PP S3300 kVA

GE SG PP S3160 kVA

GE TLE200 kW

GE TLE400 kW

0.370.480.480.750.43 0.35 0.31

footprint (m2)/100kW

Trends: Increase Power Density

Page 16: GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior

Efficiency: Space Vector Modulation technology

NEW: eBoost

High efficiency at any

load

Energy cost saving

Air conditioning cost

saving

SG CE PurePulse® rectifier – Efficiency

0%

20%

40%

60%

80%

92%100%

10% 25% 50% 75% 100%

Load

Effi

cie

ncy %

Typical Operation

Trends: Increase Power DensityTrends: Further Increase Efficiency

Page 17: GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior

Reliability: From single UPS to dual redundant systems

TM

ISM

_C

ab

ine

t_G

E_

01

UPS-A

UPS-B

Battery-A

Battery-B

ISM

STS-A

STS-B

Load-A

Load-B

Input

mains

Input

mains

UPS: Uninterruptible Power SupplyISM:Intelligent Synchronization ModuleSTS: Static Transfer Switch

Reliability: from single UPS to dual redundant systems

Page 18: GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior

g

We ensure safe and reliable power.

GECritical Power