Corporate ProfileGulf Computer Support Systems LLC 1Who We Are
Formed in 1988Offices in Abu Dhabi, Dubai, Muscat and Qatar
Specialized In
. Data center site construction. Telecom room environment. Power station products. Building technology services products. Raised access flooring & under floor air delivery systems. IT solutions. Under floor air distribution
What We DoData Center Site Construction
. TATE raised access flooring. STULZ close control air conditioning. WAGNER fire prevention, detection & oxygen reduction system by gas. TTK digital liquid leak detection system. SOCOMEC UPS . VRLA Industrial Batteries. AUTOMATIONs Containerized Datacenter . ORTEA Voltage stabilizer. AIRFIXTURE Under floor Air Distribution
Our SisterAirpotech LLC
. AIRPOTECH is a sister company of GCSS. Formed in mid of 2007. Offices in Dubai, Abu Dhabi, KSA, Muscat & Bahrain. Specialized in the supply of ground support equipment and services for the aviation sector 400 Hz Power supply equipmentPre Conditioned AirJet Blast Deflector & Ground Run-Up EnclosuresPermanent/Semi-permanent Hangars for all types of AircraftsHigh Lifters for Aircrafts up to A380 for ground handling tasksSpray Booths for Paint Shop Hangars
Organization ChartExpert Team
5
Continued
Continued
Project Management. Managing design development. Construction sequencing and scheduling. Project cost control. Managing site instructions and variations. Procurement and logistics. Managing and completing multiple large projects
Data CenterBusiness and technology decision makers often focus on factors such as performance and uptime when investing in new solutions. However, as the amount of data that companies collect grows, organizations have had to place more emphasis on a larger number of factors than they have in years past.
Our Product Range
Data Center Application
1Close Control AC Units (CCU)Germany2Raised Access FloorUSA3Leak DetectionUSA / France4UPS & Critical Power SolutionFrance5Lead Acid Battery Europe / China6Containerized data center7Fire Prevention SystemGermany8Under floor Air DistributionUSA9Smart BunkerGermany
STULZ CCU
Close Control AC Units (CCU) 1
11
STULZ CCU. Close Control Units [Direct Expansion, Chilled Water, Dual Coil (DX+CW), etc]. CyberRow Units. Condensers. Chillers. Telecom Range
STULZ CCU
Cyber Air Series
STULZ CCUEC Fan Technology
High efficiency / Low power consumptionBenefits:Scalable air volume setting via Controlleron demandDirect drive technology, no beltsLow vibrationFeatures:Energy savings compared to standard fans (using stand-by units) equals increased net cooling capacityEasy adaption to changing space conditionsAdditional energy savingsReduced noise levelsLong and maintenance-free operationNo abrasion,No belt dust ,No additional filtrationQuiet running AC unit
STULZ CCUKey Element Cooling Std-by Management
Sample: 3x ASD1500CW At 24C/50% with 7/12C water incl. 1/3 standby capacity
Standby 3x 75.1 = 225.3 kW net sensibleAirflow: 2x 29,000 m/hFan absorbed power: 2x 8.0 = 16,0 kWLpa,2m = 2x 59.7dBA = 62.7dBA Airflow: 3x 19,000 m/hFan absorbed power: 3x 2.3 = 6,9 kWLpa,2m = 3x 50.8dBA = 55.6dBA 2x 112,1 = 224.2 kW net sensibleBenefits:Considerable energy savings => Energy saving: 9.1kW x 8760hr x 0.20Fils = AED15.945/Y Reduced noise levels => Noise reduction: -7.1 dBA 2TATE ACCESS FLOOR
Raised Access Flooring
16
TATE Access FloorAccess Floor
Removable square tiles providing plenum for air to circulate below the floor as part of the air conditioning system, as well as to process piping, power wiring and data cabling.
Understructure systems to accommodate floor heights from 12 to 60, however, 24 to 36 FFH are typical.
TATE Access FloorConcore Panels
Epoxy coated unitized shells consisting of a flat steel top sheet welded to a formed steel bottom sheet filled with a highly controlled mixture of lightweight cement. Manufactured to exacting tolerances, these noncombustible rigid, solid panels deliver the ultimate in strength, durability, and acoustic performance.
TATE Access FloorPerforated Panels
Are primarily used in applications requiring delivery of conditioned air to equipment for the purposes of cooling the equipment.
Typically be used in equipment room applications such as telecommunication switch centers, data centers, & corporate computer rooms.
TATE Access Floor. Understructure Systems:. PosiLock. Low Finished Floor Height PosiLock. Bolted Stringer
TATE Access FloorHeight of Raised Floor
Small Data Centers / Server Rooms(465 sq m)24 in (60cm) or more 3TTK LEAK DETECTOR
Leak Detection System
22
TTK Leak DetectionPrinciple of Liquid Leak Detection
Water contact with the sensing cableActivation of audible alarm & luminous on FG-SYS Digital Control PanelWitness of zone @ fault passes from green to redDisplay of zone name and location of the leak point on the FG-SYS LCD screenDisplay of date & time of the leak beginning The contacts of defect are activatedInformation is transmitted in mode JBUS on exit RS232/RS485
4SOCOMEC UPS
Uninterruptible Power Supply
24
SOCOMEC UPSUninterruptible Power Supply
A complete power Solution for Data Centers and Server Farms
Manufactured in Europe Modulys UPS : 1.5 kVA to 24 kVA A Perfect Modular UPS for Datacenter, server farms and Computer NetworksModulys GP : 25 to 600 kVA/kW ups Highly reliable Modular UPS with Unity power factorVertically and Horizontally Scalable UPS Fully Modular and N+1, N+2 cost effective redundant SystemEasy to install and Hot swappable modules
Modulys UPSModulys GP UPS
SOCOMEC UPS
UPS three / single phase MASTERYS BC : 8 kVA to 12 kVAMASTERYS BC : 15kVA to 20 kVAMASTERYS GP : 10kVA to 20 kVA
UPS three / three phase MASTERYS BC : 8 kVA to 12 kVAMASTERYS BC : 15kVA to 120 kVAMASTERYS BC : 160kVA to 300 kVAUPS single/single-phaseNETYS PL : 600 VA and 800 VANETYS PE : 600 VA TO 2000 VANETYS PR 1000 VA TO 2000 VAUninterruptible Power Supply
5VRLA Battery
LEAD-ACID Battery
27
VRLA Battery VRLA Battery
(SMF) Valve Regulated Lead Acid BatteryMade in High Tech manufacturing plantSealed Maintenance Free Battery Specifically made for UPS & TelecomAGM (Absorbent Gel Material) and GEL Technology Vast range : 7Ah to 3000 Ah
6Automations Prefabricated Modular Containerized Datacenter
Containerized Data Centre
29 7WAGNER FIRE PREVENTION
Fire Prevention Systems
30
Fire Prevention SystemsOxy Reduct
OxyReduct offers active fire prevention
Fire Prevention SystemsOxy Reduct
Produces nitrogen in order to reduce the oxygen vol. concentration in the room down to 15% where a fire cannot start yet people can continue to be present without side effects.
Early Detection SystemsAspiration Detection SystemHeatdetectorsDtPoint-typeSmoke detectorsDtASDDtTITANUS-Start of countermeasures after DttIntensity of fire(logarithmic graph)
Early Detection Systems
Aspiration Detection System
8AIRFIXTURE UNDERFLOOR AIR DIST
Under Floor Air Distribution
35
AIRFIXTURE
Under floor Air Distribution 9Smart Bunkers
Smart Bunker
37
Smart Bunker
Smart Bunker By AST / Cooling by STULZ
Including:
Safe cabinet with lock cooling system UPS Fire system Fits couple of servers
Cooling SolutionsCooling Load & Air Distribution
Cooling SolutionsCold Aisle / Hot Aisle arrangment
Cooling SolutionsCooling (Aisle Containment) / By TATE
Retractable roofFire Suppression compatible
Cooling SolutionsCyberRow (InRow) Cooling / By STULZFor High Density Areas
Cooling SolutionsSmart Air Booster
PowerAireSmartAire
AirBoosterPro
References
44
References2000m2 DC white space @ IMPZ DXB Goverment
45
References2000m2 DC @ PDO Oman
46
ReferencesDU & Etisalat
47
ReferencesTwoFour54 - Mubadala
48
ReferencesAbu Dhabi Financial Centre @ Sowwa Island - TATE49NATIONAL DRILLING CO. New H.Q. Abu DhabiTATE - 10,200 m2
ReferencesEtisalatT&A BuildingAbu Dhabi, Al Ain,Sharjah (10,000m2)
50NBAD New H.Q, Abu DhabiTATE - 15,000 m2
COMMERCIAL BANK OF DUBAI New H.Q. Dubai TATE - 16,200 m2
References
51ADCB New H.Q. Abu DhabiTATE 20,000 m2
AL SALAM AVENUE TOWERAbu DhabiTATE 18,400 m2
References
52
LANDMARK TOWERAbu DhabiTATE 45,000 m2
References53Contact Us
Dubai, UAEPO Box 13131 | Dubai | UAETel : +971 4 380 6010 | Fax : +971 4 380 6060Email : [email protected]
Socially near to you Abu Dhabi, UAEPO Box 44268 | Abu Dhabi | UAETel : +971 2 631 9931 | Fax : +971 2 634 6071Email : [email protected], OMAN18th November Street | Al Ozaiba | Muscat | OmanTel : +968 2 449 3269 | Fax : +968 2 449 1437Email : [email protected], QATARDoha | QatarTel : +974 555 09855Email : [email protected]:http://www.facebook.com/pages/Gulf-Computer-Support-Systems/292553544157477
Tweet:https://twitter.com/#!/GulfComputerSup
in:http://www.linkedin.com/profile/view?id=18068312454
Questions & Discussions
55