10
ARCHITECTS GCPS: ACCIDENT ELEMENTARY SCHOOL VESTIBULE MODIFICATIONS VICINITY MAP LOCATION MAP NOT TO SCALE NOT TO SCALE GCPS: ACCIDENT ELEMENTARY SCHOOL VESTIBULE MODIFICATIONS BFM # 20002 MARCH 13, 2020 ACCIDENT, MARYLAND DRAWING INDEX CS-1 COVER SHEET ARCHITECTURAL: D1.1 DEMO FLOOR PLAN ELECTRICAL: E1.1 DEMO ELECTRICAL PLAN PSC No. 11.012.20 534 ACCIDENT BITTINGER RD. ACCIDENT, MD 21520 MARCH 13, 2020 A1.1 FLOOR PLAN A2.1 SCHEDULE A2.2 DOOR & WINDOW DETAILS A8.1 CEILING PLAN E1.2 NEW ELECTRICAL PLAN A6.1 INTERIOR ELEVATIONS D1.1 DEMO CEILING PLAN GCPS BID No. AC20-01

GCPS: ACCIDENT ELEMENTARY SCHOOL VESTIBULE … · 102vestibule f1 / f2b1 / b4w5 w2w4 / w5w5 c1 v.i.f.- 103vestibule f2 b5w4 / w5w4 / w5w5 w2 c1 v.i.f. provide mtl transition strip

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GCPS: ACCIDENT ELEMENTARY SCHOOL VESTIBULE … · 102vestibule f1 / f2b1 / b4w5 w2w4 / w5w5 c1 v.i.f.- 103vestibule f2 b5w4 / w5w4 / w5w5 w2 c1 v.i.f. provide mtl transition strip

ARCHITECTS

GCPS: ACCIDENT ELEMENTARY SCHOOLVESTIBULE MODIFICATIONS

VICINITY MAP LOCATION MAPNOT TO SCALENOT TO SCALE

GC

PS: A

CC

IDE

NT

EL

EM

EN

TA

RY

SC

HO

OL

VE

STIB

UL

E M

OD

IFIC

AT

ION

SB

FM #

200

02

MA

RC

H 1

3, 2

020

AC

CID

EN

T, M

AR

YL

AN

D

DRAWING INDEXCS-1 COVER SHEET

ARCHITECTURAL:

D1.1 DEMO FLOOR PLAN

ELECTRICAL:

E1.1 DEMO ELECTRICAL PLAN

PSC No. 11.012.20

534 ACCIDENT BITTINGER RD.ACCIDENT, MD 21520

MARCH 13, 2020 A1.1 FLOOR PLAN

A2.1 SCHEDULE

A2.2 DOOR & WINDOW DETAILS

A8.1 CEILING PLAN

E1.2 NEW ELECTRICAL PLAN

A6.1 INTERIOR ELEVATIONS

D1.1 DEMO CEILING PLAN

GCPS BID No. AC20-01

AutoCAD SHX Text
(301)733-5600 FAX (301)733-5612
AutoCAD SHX Text
HAGERSTOWN, MARYLAND 21740
AutoCAD SHX Text
473 NORTH POTOMAC STREET
AutoCAD SHX Text
BFMARCHITECTS.COM
AutoCAD SHX Text
DATE :
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
BFMARCHITECTS.COM | 301-733-5600 | Fax 301-733-5612
AutoCAD SHX Text
473 NORTH POTOMAC STREET, HAGERSTOWN, MD 21740
AutoCAD SHX Text
CS.1
AutoCAD SHX Text
COVER SHEET
AutoCAD SHX Text
03.13.20
AutoCAD SHX Text
1
AutoCAD SHX Text
( date )
AutoCAD SHX Text
were prepared under my supervision
AutoCAD SHX Text
information and belief, they comply
AutoCAD SHX Text
and to the best of my knowledge,
AutoCAD SHX Text
PROFESSIONAL CERTIFICATION
AutoCAD SHX Text
These contract documents for the
AutoCAD SHX Text
Maryland Registration No. 10011 Expiration Date: 7/7/20
AutoCAD SHX Text
/s/
AutoCAD SHX Text
with the relevant building codes of the
AutoCAD SHX Text
State of Maryland.
AutoCAD SHX Text
GCPS: ACCIDENT ELEMENTARY SCHOOL
AutoCAD SHX Text
VESTIBULE MODIFICATIONS
AutoCAD SHX Text
BID SET
Page 2: GCPS: ACCIDENT ELEMENTARY SCHOOL VESTIBULE … · 102vestibule f1 / f2b1 / b4w5 w2w4 / w5w5 c1 v.i.f.- 103vestibule f2 b5w4 / w5w4 / w5w5 w2 c1 v.i.f. provide mtl transition strip

PRINCIPAL(E)

GENERAL OFFICE(E)

HEALTH(E)

WORK / STORAGE(E)

WOMEN(E) MEN(E)

CAFETERIA(E)

TEACHER LOUNGE(E)

3

3

3

3

4 1A

1A

1A

1

1

1 1

11

6

5

2

VAULT(E)

10

(E) T.B.

11

113

13

(E) DESK

(E) WALL HEATER

(E) SHELF

7

(E) F

.C.

(E) F

.C.

(E) BED

(E) DESK(E

) BED

12

1212

12

(E) WALLHEATER

(E) WALL HEATER

12

7 14

15

5

7

(E) DESK

(E) BEAM ABOVE

3

4'-5

"2'

-8"

2'-8

"8'

-6"

(E) INTERCOM

15

(E) BENCH RELOCATEAS REQ'D

(E) BENCH

2

DOOR RELOCATEDTOO DOOR NUMBER107 - SEE NEW PLAN

DOOR RELOCATEDTOO DOOR NUMBER105 - SEE NEW PLAN

DOOR RELOCATEDTOO DOOR NUMBER105A - SEE NEW PLAN

(E) VCT

(E) VCT

(E) VCT

(E) VCT

(E) CARPET

(E) CARPET

8

CONF. ROOM(E)

(E) WALL HEATER- REMOVE & CAP ELECT. FEED

(E) F.E.

(E) PULL STATION

(E) STROBE

(E) FIRST AID KITS

16

(E) T.B.

14

(E) TERRAZZO

CORRIDOR(E)

97 3'-4

"3'

-4"

4" 3'-4"

4"3'-4"

4" 3'-4"

NOTE: CONTRACTOR TO PATCH AND REPAIR AREASWHERE ELECTRICAL OUTLETS/DEVICES OR OTHERITEMS ARE REMOVED FROM WALL/CEILINGS, MATCHADJACENT FINISHES - TYP. ALL AREAS OF WORK

16

(E) CANOPY ABOVELINE OF (E) BULKHEAD ABOVE

DEMOLITION NOTES

REMOVE (E) DOOR UNIT FRAME & FRAMEGLAZING AS SHOWN- PATCH & REPAIRADJACENT WALLS & FLOOR AS REQUIRED.

REMOVE (E) DOOR & FRAME - RELOCATE DOORPER DOOR SCHEDULE

REMOVE (E) CEILING MATERIAL - PATCH & REPAIRADJACENT WALLS AS REQUIRED. - SEE SHT. D8.1

REMOVE (E) MTL STUD & GYP BD. WALL - PATCH& REPAIR ADJACENT WALLS & FLOOR ASREQUIRED.

REMOVE AND RELOCATE (E) TV ANDASSOCIATED EQUIPMENT - PATCH AND REPAIRADJACENT FINISHES AS REQUIRED

REMOVE (E) CASEWORK - PATCH AND REPAIRADJACENT FINISHES AS REQUIRED

REMOVE AND RELOCATE (E) MAILBOXES- PATCH AND REPAIR ADJACENT FINISHES ASREQUIRED

REMOVE (E) TACK BOARD - PATCH AND REPAIRADJACENT FINISHES AS REQUIRED

REMOVE & RELOCATE (E) REFRIGERATOR -PATCH & REPAIR ADJACENT FINISHES ASREQUIRED

REMOVE (E) WALL HEATER - REMOVE & CAPELECT. FEED - PATCH AND REPAIR ADJACENTFINISHES AS REQUIRED

REMOVE (E) WINDOW UNIT & FRAME - PATCH &REPAIR ADJACENT FINISHES AS REQUIRED

REMOVE & RELOCATED (E) CASEWORK - PATCHAND REPAIR ADJACENT FINISHES AS REQUIRED

REMOVE (E) WALLPAPER, PATCH & REPAIRSURFACE, SKIM COAT, & PREP FOR PAINT

REMOVE & RELOCATE (E) PRINTER & ALLASSOCIATED CONNECTIONS AND HARDWARE.- PATCH & REPAIR ADJACENT FINISHES ASREQUIRED

REMOVE (E) CARPET & PREPARE SLAB FOR NEWFLOORING SURFACE - WORK PER ALTERNATE

REMOVE & RELOCATE (E) BENCH

REMOVE & RELOCATE (E) BOX

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

1A

16

©

DRAW

ING

INTE

NT IS

TO

IN

DICA

TE G

ENER

AL

ARRA

NGEM

ENT,

DESI

GN

AND

INTE

NT O

F W

ORK

IS P

ARTL

Y DI

AGRA

MM

ATIC

. IT S

HALL

NO

T BE

SCA

LED

FOR

ROUG

H-IN

MEA

SURE

MEN

TS

OR

SERV

E AS

ERE

CTIO

N SH

OP

DRAW

ING

S.

CONT

RACT

OR

IS

RESP

ONS

IBLE

FO

R VE

RIFIC

ATIO

N O

F DI

MEN

SIO

NS

MAR

YLAN

D.TH

E LA

WS

OF

THE

STAT

E O

F

I CER

TIFY

THAT

THE

SE

LICEN

SED

ARCH

ITECT

UND

ER

BY M

E, A

ND T

HAT

I AM

A D

ULY

DOCU

MEN

TS W

ERE

EXPI

RATIO

N DA

TE

LICEN

SE N

o.

PREP

ARED

OR

APPR

OVE

D

100

11

7.7.

20

BID DOCUMENTS

XREF

S: T

ITLEB

L

2 0 2 4 6 8 101/4" = 1'-0"

SCALE FEET

1

D1.11/4" = 1'-0" KEY PLANNO SCALE

AREA OF WORK

AutoCAD SHX Text
, BUSHEY FEIGHT MORIN ARCHITECTS, INC.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
:
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEETS
AutoCAD SHX Text
BFMARCHITECTS.COM | 301-733-5600 | FAX 301-733-5612
AutoCAD SHX Text
473 NORTH POTOMAC STREET, HAGERSTOWN, MD 21740
AutoCAD SHX Text
BFM# 20002
AutoCAD SHX Text
GCPS: ACCIDENT ELEMENTARY SCHOOL
AutoCAD SHX Text
VESTIBULE MODIFICATIONS
AutoCAD SHX Text
03.13.20
AutoCAD SHX Text
2020
AutoCAD SHX Text
D1.1
AutoCAD SHX Text
DEMO FLOOR
AutoCAD SHX Text
PLAN
AutoCAD SHX Text
1
AutoCAD SHX Text
DEMO PLAN
Page 3: GCPS: ACCIDENT ELEMENTARY SCHOOL VESTIBULE … · 102vestibule f1 / f2b1 / b4w5 w2w4 / w5w5 c1 v.i.f.- 103vestibule f2 b5w4 / w5w4 / w5w5 w2 c1 v.i.f. provide mtl transition strip

(E) T.B.

32 1

1

1

3

4

5

CEILING DEMOLITION NOTES

REMOVE & RELOCATE (E) LIGHTING FIXTURES - PATCH &REPAIR ADJACENT FINISHES AS REQUIRED

REMOVE (E) LIGHTING FIXTURE - PATCH & REPAIRADJACENT FINISHES AS REQUIRED

REMOVE (E) CEILING MATERIAL - PATCH & REPAIRADJACENT WALLS AS REQUIRED. AREAS INDICATED BY

REMOVE & RELOCATE (E) SPEAKER - PATCH & REPAIRADJACENT FINISHES AS REQUIRED

REMOVE & RELOCATE (E) EXIST SIGN - PATCH & REPAIRADJACENT FINISHES AS REQUIRED

1

3

2

4

5

3

2

EXHAUST

RETURN

SUPPLY

LINEAR SUPPLY GRILL

GYP. BD. BULKHEAD

GYP. BD. CEILING

DUCT MOUNTEDSUPPLY GRILL

NEW 2' x 4' ACOUSTICALTILE AND GRID - HATCHED

FLUORESCENT RECESSEDLIGHT FIXTURE (EXISTING)

FLUORESCENT RECESSEDLIGHT FIXTURE (NEW)

12" Ø TRACK MOUNTEDPENDANT LIGHT FIXTURE

4' SURFACE MOUNTEDLIGHT FIXTURE

4' STRIP LIGHT FIXTURESUSPENDED ABOVETRANSLUCENT PANELS

DOWN LIGHT

1x2 WALL MOUNTEDLIGHT FIXTURE

EXIT SIGN - SINGLE SIDEDEXIT SIGN - DOUBLE SIDED

12" Ø DECORATIVE PENDANTLIGHT FIXTURE

SOFFIT PANELS

WALL MOUNTED LIGHT

EMERGENCY LIGHTING

(E) 2' x 4' ACOUSTICALTILE AND GRID

(E) DOWN LIGHT

4' SURFACE MOUNTEDLIGHT FIXTURE (EMERGENCY)

SPEAKERSPRINKLER HEAD (EXISTING)

©

DRAW

ING

INTE

NT IS

TO

IN

DICA

TE G

ENER

AL

ARRA

NGEM

ENT,

DESI

GN

AND

INTE

NT O

F W

ORK

IS P

ARTL

Y DI

AGRA

MM

ATIC

. IT S

HALL

NO

T BE

SCA

LED

FOR

ROUG

H-IN

MEA

SURE

MEN

TS

OR

SERV

E AS

ERE

CTIO

N SH

OP

DRAW

ING

S.

CONT

RACT

OR

IS

RESP

ONS

IBLE

FO

R VE

RIFIC

ATIO

N O

F DI

MEN

SIO

NS

MAR

YLAN

D.TH

E LA

WS

OF

THE

STAT

E O

F

I CER

TIFY

THAT

THE

SE

LICEN

SED

ARCH

ITECT

UND

ER

BY M

E, A

ND T

HAT

I AM

A D

ULY

DOCU

MEN

TS W

ERE

EXPI

RATIO

N DA

TE

LICEN

SE N

o.

PREP

ARED

OR

APPR

OVE

D

100

11

7.7.

20

BID DOCUMENTS

XREF

S: T

ITLEB

L

2 0 2 4 6 8 101/4" = 1'-0"

SCALE FEET

1

D8.11/4" = 1'-0" KEY PLANNO SCALE

AREA OF WORK

2

D8.11/4" = 1'-0"

AutoCAD SHX Text
%%uLIGHTING LEGEND
AutoCAD SHX Text
%%uMECH. LEGEND
AutoCAD SHX Text
%%UCEILING TYPES
AutoCAD SHX Text
, BUSHEY FEIGHT MORIN ARCHITECTS, INC.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
:
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEETS
AutoCAD SHX Text
BFMARCHITECTS.COM | 301-733-5600 | FAX 301-733-5612
AutoCAD SHX Text
473 NORTH POTOMAC STREET, HAGERSTOWN, MD 21740
AutoCAD SHX Text
BFM# 20002
AutoCAD SHX Text
GCPS: ACCIDENT ELEMENTARY SCHOOL
AutoCAD SHX Text
VESTIBULE MODIFICATIONS
AutoCAD SHX Text
03.13.20
AutoCAD SHX Text
2020
AutoCAD SHX Text
D8.1
AutoCAD SHX Text
DEMO CEILING
AutoCAD SHX Text
PLAN
AutoCAD SHX Text
1
AutoCAD SHX Text
DEMO CEILING PLAN : BASE BID
AutoCAD SHX Text
DEMO CEILING PLAN : ALTERNATE
Page 4: GCPS: ACCIDENT ELEMENTARY SCHOOL VESTIBULE … · 102vestibule f1 / f2b1 / b4w5 w2w4 / w5w5 c1 v.i.f.- 103vestibule f2 b5w4 / w5w4 / w5w5 w2 c1 v.i.f. provide mtl transition strip

WOMEN(E) MEN(E)

CAFETERIA(E)

TEACHER LOUNGE(E)

103

101

105

105A

107

106

102A

MAILBOXES

NEW COUNTER- PER ALT. 2

VAULT(E)

VESTIBULE101

VESTIBULE103

LOBBY104

PRINCIPA.L105

WORK / STORAGE106

HEALTH107

4'-0"3'-4"3'-0"

3'-4

"

6'-4"

4"

(E) T.B.

(E) WALL HEATER

(E) SHELF

(E) F

.C.

(E) F

.C.

(E) BED

(E) DESK(E

) BED

(E) WALLHEATER

(E) WALL HEATER

W2

RELOCATEDCASEWORK

RELOCATEDBENCH

(E) DESK

RELOCATED COPIER

EXTEND (E) WALL ABOVEDOORS TO DECK ABOVE- VERIFY CONSTRUCTIONIN FIELD

EXTEND (E) WALL ABOVEDOORS TO DECK ABOVE- VERIFY CONSTRUCTIONIN FIELD

(E) BEAM ABOVE

W2

W3

102

104A104

3'-0

"

3'-0"

P-1

(E) INTERCOM

RELOCATEDDESKRELOCATED

CASEWORK

RELOCATEDCASEWORK

(E) BENCH RELOCATEAS REQ'D

(E) BENCH

CONF. ROOM(E)

ADA

ADA

6'-0"

RELOCATEDT.B.

RELOCATEDREFRIGERATOR

5'-0

"

4'-6 1/2"

NEW MTL.TRANSITION STRIP

ADA

1A6.1

6'-0"

(E) F.E.

(E) PULL STATION

(E) STROBE

(E) FIRST AID KITS

4A6.1

11'-4"

2'-6

"(E) T.B.

NEW CARPET

1'-2"

3'-4

"4'

-5"

ADA

13'-1

0 1/

2"

GENERAL OFFICE108

108

NEW

CA

RPET

RELOCATEDBENCH

CRADA

RELOCATED A-PHONE

(E) TERRAZZO

P-2

5'-0"

2A6.1

-

C

B

A

CORRIDOR(E)3'-4"4"

3'-4"

ADA

ADA

NEW MTL.THRESHOLD

(E) CANOPY ABOVE

CR

RELOCATED SHELF& CLOCK SYSTEM

3'-4" 4"

NEW KNOX BOXMOUNTED @ 7'-0" A.F.F.

RELOCATED BOX

P-1

(E) V

CT

(E) VCT

(E) V

CT

ADA

NEW PERFORATEDMTL PANEL

1A2.1

10'-2

"4

1/2"

19'-7

1/2"

6'-1

1 1/2

"

W2

ADA

VESTIBULE102

105A

107

106

WORK / STORAGE106

4"

(E) T.B.

(E) F

.C.

(E) BED

3'-0"

P-1

RELOCATEDCASEWORK

6'-0" 6'-0"

108STOR.109

(E) T.B.

ALT. No. 1

2A6.1

-

C

B

A

P-1

P-1

3'-4"4"

©

DRAW

ING

INTE

NT IS

TO

IN

DICA

TE G

ENER

AL

ARRA

NGEM

ENT,

DESI

GN

AND

INTE

NT O

F W

ORK

IS P

ARTL

Y DI

AGRA

MM

ATIC

. IT S

HALL

NO

T BE

SCA

LED

FOR

ROUG

H-IN

MEA

SURE

MEN

TS

OR

SERV

E AS

ERE

CTIO

N SH

OP

DRAW

ING

S.

CONT

RACT

OR

IS

RESP

ONS

IBLE

FO

R VE

RIFIC

ATIO

N O

F DI

MEN

SIO

NS

MAR

YLAN

D.TH

E LA

WS

OF

THE

STAT

E O

F

I CER

TIFY

THAT

THE

SE

LICEN

SED

ARCH

ITECT

UND

ER

BY M

E, A

ND T

HAT

I AM

A D

ULY

DOCU

MEN

TS W

ERE

EXPI

RATIO

N DA

TE

LICEN

SE N

o.

PREP

ARED

OR

APPR

OVE

D

100

11

7.7.

20

BID DOCUMENTS

XREF

S: T

ITLEB

L

2 0 2 4 6 8 101/4" = 1'-0"

SCALE FEET

1

A1.11/4" = 1'-0" KEY PLANNO SCALE

AREA OF WORKWALL FINISH KEY

C

AD B

2

A1.11/4" = 1'-0"

AutoCAD SHX Text
, BUSHEY FEIGHT MORIN ARCHITECTS, INC.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
:
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEETS
AutoCAD SHX Text
BFMARCHITECTS.COM | 301-733-5600 | FAX 301-733-5612
AutoCAD SHX Text
473 NORTH POTOMAC STREET, HAGERSTOWN, MD 21740
AutoCAD SHX Text
BFM# 20002
AutoCAD SHX Text
GCPS: ACCIDENT ELEMENTARY SCHOOL
AutoCAD SHX Text
VESTIBULE MODIFICATIONS
AutoCAD SHX Text
03.13.20
AutoCAD SHX Text
2020
AutoCAD SHX Text
A1.1
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
PLAN
AutoCAD SHX Text
1
AutoCAD SHX Text
PARTIAL FLOOR PLAN : BASE BID
AutoCAD SHX Text
PARTIAL FLOOR PLAN : ALTERNATE
Page 5: GCPS: ACCIDENT ELEMENTARY SCHOOL VESTIBULE … · 102vestibule f1 / f2b1 / b4w5 w2w4 / w5w5 c1 v.i.f.- 103vestibule f2 b5w4 / w5w4 / w5w5 w2 c1 v.i.f. provide mtl transition strip

MAT'L.NO

DOOR

ROOM LOCATION SIZE TYPEREMARKS

DOOR SCHEDULEFRAME

TYPEGLAZ MAT'L. GLAZWIDTH JAMB THRSHEADHARD-WARE

SIGNAGE LABEL

101 VESTIBULE 3'-0" x 7'-0" 1 ALUM G7 C ALUM 4 1/2" G7 1 2 ALUM 1 THERMALLY BROKEN, BRONZE ( )

DETAILSSEE SHEET A2.2

1" INSULATED TEMPERED GLASS UNITS

DESCRIPTION

NOT USED

3/8" LAMINATED SAFETY GLASS- CLEAR

G-7

G-6

G-5

G-4

G-3

G-2

G-1

TYPE

GLAZING LEGEND

NOT USED

NOT USED

NOT USED

NOT USED

INSULATED ALUM. PANELG-8

102 VESTIBULE (2) 3'-0" x 7'-0" 1 / 1 ALUM G7 C ALUM 4 1/2" G7 1 2 ALUM 3 THERMALLY BROKEN, BRONZEREMOVABLE MULLION

102A VESTIBULE 3'-0" x 7'-0" 1 ALUM G7 C ALUM 4 1/2" G7 1 2 ALUM 4 THERMALLY BROKEN, BRONZE ( )

103 VESTIBULE 3'-0" x 7'-0" 1 ALUM G7 B ALUM 4 1/2" G7 3 4 2 OFFICE (#) BRONZE ( )-

104 LOBBY (2) 3'-0" x 7'-0" 1 / 1 ALUM G7 D ALUM 4 1/2" G7 3 4 ALUM 3 BRONXEELECTRONIC LOCKSET

104A LOBBY 3'-0" x 7'-0" 1 ALUM G7 D ALUM 4 1/2" G7 3 4 ALUM 4 BRONZE : CARD READER / ADATIME CLOCK ( )

105 PRINCIPAL 3'-0" x 7'-0" (E) 2 SC WD - A HM 5 1/2" - 5 6 ALUM 5 PRINCIPAL (#) DOOR FROM PRINCIPAL

105A PRINCIPAL 3'-0" x 7'-0" (E) 2 SC WD - A HM 5 1/2" - 5 6 ALUM 5 PRINCIPAL (#) DOOR FROM HEALTH ROOM

106 WORK / STORAGE 3'-0" x 7'-0" (E) 2 SC WD - A HM 5 1/2" - 5 6 ALUM 5 CONFERANCE (#) DOOR FROM LOBBY

107 HEALTH 3'-0" x 7'-0" 2 SC WD - A HM 5 1/2" - 5 6 ALUM 5 HEALTH (#) --

109 STORAGE (ALTERNATE) 3'-0" x 7'-0" 2 SC WD - A HM 5 1/2" - 5 6 ALUM 6 STORAGE (#) 1 HR ALTERNATE No. 1-

108 GENERAL OFFICE 3'-0" x 7'-0" (E) 2 SC WD - A (E) HM 5 1/2" - 5 6 - 7 - NEW CLOSER-

# MATCH EXISTING SIGNAGE

· DOOR CONTROLS, CARD READER, ADABUTTON, TIME ZONE OR REMOTE RELEASE

- COORDINATE w/ HARDWARE

Ω ELECTRICAL REQUIREMENTS

Ω

ROOM FINISH SCHEDULEWALLFLOORNAMENO BASE

A B

CEILING

C D MAT'L HT

REMARKS

101 VESTIBULE F1 / F2 B1 / B4 / B5 W4 / W5 W4 / W5 W5 W2 / W4 C1 / C3 V.I.F. TILE WAINSCOT - MATCH EXIST. HT.

F1 B1 W1 C1

F2

F3

LEGENDFLOORS BASE WALLS CEILINGS

EXISTING BRICK EXISTING ACOUSTICAL CLG TILEEXIST GYP BD - PAINT

W2 EXISTING BRICK

NEW WALK OFF MAT (BY OWNER)

EXISTING TERRAZZO

W3 EXISTING WALL TILE - V.I.F.

C2 EXISTING VINYL SOFFIT B2

B3

EXISTING VINYL BASE

EXISTING CARPET

102 VESTIBULE F1 / F2 B1 / B4 W5 W2 W4 / W5 W5 C1 V.I.F. -

103 VESTIBULE F2 B5 W4 / W5 W4 / W5 W5 W2 C1 V.I.F.PROVIDE MTL TRANSITION STRIP AT OPENING

104 LOBBY F2 B3 / B5 - W1 / W3 W4 / W5 W4 / W5 C1 / C3 V.I.F. PATCH & MATCH EXIST FINISHES

105 PRINCIPAL F3 B4 W1 / W4 W1 / W4 W1 W1 / W4 C1 V.I.F. NOTE No. 1 - NO WAISCOT

106 WORK / STORAGE F4 B2 W1 W1 W1 W1 C1 V.I.F. NOTE No. 1

107 HEALTH F4 B2 / B4 W1 W1 / W4 W1 W1 C1 V.I.F. NOTE No. 1

C3 ACOUSTICAL CLG TILE

W4 NEW GYP BD - w/ TILE WAINSCOT B4 NEW VINYL BASE

EXISTING TILE BASE

W5 STOREFRONT B5 NEW TILE BASE

108 GENERAL OFFICE F5 / F6 B2 / B3 / B4 W1 W3 / W4 W1 / W4 W1 / W4 C1 V.I.F. -

(E) CORRIDOR F4 B2 W1 - W1 W1 C1 V.I.F. -

(E) CONFERENCE ROOM F3 B2 W1 W1 W1 / W4 W1 C1 V.I.F. -

F4 EXISTING VCT

F5 NEW CARPET

F6 NEW VCT

NOTE No.1 : REMOVE EXIST. WALL PAPER,PATCH & REPAIR WALL SURFACE SKIM COATw/ JOINT COMPOUND, SMOOTH & PAINT

109 STORAGE (ALTERNATE) F4 B2 W1 W1 / W4 W1 W1 C1 V.I.F. NOTE No. 1

A

FRA

ME

TYPE

S

FIN.FLR.

B

SEE SCHED.

10"

SEE

SC

HED

ULE

7"

7" 7"

G-7

FIN.FLR.

DO

OR

TYPE

SW

IND

OW

TY

PES

G-7

2'-4

"8"

2'-7

"

W1

1

FIN.FLR.

W2

7'-0

"2"

3'-0"2" 2"

SEE SCHED.

SEE

SC

HED

ULE

2

C D

G-4

G-4

G-7

G-7

G-7

G-7

G-7

G-7DR WIDTH DR WIDTH DR WIDTH DR WIDTH

REM

OV

ABL

E M

ULLI

ON

G-4

G-4

G-4

G-4DR WIDTH DR WIDTH DR WIDTH

REM

OV

ABL

E M

ULLI

ON

3'-6

"2"

3'-0

"4"

2"

1'-6"2" 3'-0"2" 2" 11"2" 3'-0"2" 3'-0" 3'-0" 3'-0"2" 2"2" 2"10 1/4"2"

8 1/2" 10 1/4"2" 3'-0" 3'-0" 3'-0"2" 4" 2" 2"

10 1/4"2"

10 1/4"2"

2"3'

-6"

2"3'

-0"

4"

2"3'

-6"

2"3'

-0"

4"

G-4 G-4 G-4 G-4

90°

3'-6

"2"

2"3'

-4"

90°

G-4 G-4 G-4

19'-7 1/2" 5'-4 1/2" 3'-0 1/2"

3'-4 1/2"2"4 1/2"

2'-5" 2" 2" 2"2'-5" 2'-5" 2'-5"1'-4 1/4"4 1/2" 4 1/2"

SEE

SC

HED

ULE

SEE SCHED.

3'-4

"3'

-2"

6" 6"

3

4"

2'-8

1/2"

3'-0

"

2'-8 1/2"1 3/4" 1 3/4"

1 1/2

"2'

-4 3

/4"4

"

W3

4/A

2.2

3/A2.2 3/A2.2

2/A

2.2

1/A2.21/A2.25/A2.2

6/A

2.2

5/A2.2

6/A

2.2

7/A

2.2

8/A

2.2

10/A

2.2

10/A

2.2

G-7

G-7

G-4

2"

G-4G-4

2"2" 3'-4"3'-4"3'-4"

11/A2.2

NOT USED 8'-0

"

VESTIBULE101 VESTIBULE102

MTL 'J' TRIM AROUNDPERIMETER OF PANELFASTENER @ 24" O.C.

7/8" THK. PERFORATEDCORRUGATED PANELS (2)PANELS BACK TO BACK w/BRONZE FINISH EXPOSEDON VISIBLE SURFACE

7/8"

FASTENER @ 24" O.C.MTL 'J' TRIM AROUNDPERIMETER OF PANEL NEW DOOR MULLION

MTL 'J' TRIM AROUNDPERIMETER OF PANEL

DASHED LINE OFTRIM BELOW

7/8" THK. PERFORATEDCORRUGATED PANELS (2)PANELS BACK TO BACK w/BRONZE FINISH EXPOSEDON VISIBLE SURFACE

7/8"

VESTIBULE101

VESTIBULE102

7/8" THK. PERFORATED CORRUGATED PANELS(2) PANELS BACK TO BACK w/ BRONZE FINISHEXPOSED ON VISIBLE SURFACE

STICH SCREWS@ 1'-0" O.C.

1'-0

"

8'-0

"

©

DRAW

ING

INTE

NT IS

TO

IN

DICA

TE G

ENER

AL

ARRA

NGEM

ENT,

DESI

GN

AND

INTE

NT O

F W

ORK

IS P

ARTL

Y DI

AGRA

MM

ATIC

. IT S

HALL

NO

T BE

SCA

LED

FOR

ROUG

H-IN

MEA

SURE

MEN

TS

OR

SERV

E AS

ERE

CTIO

N SH

OP

DRAW

ING

S.

CONT

RACT

OR

IS

RESP

ONS

IBLE

FO

R VE

RIFIC

ATIO

N O

F DI

MEN

SIO

NS

MAR

YLAN

D.TH

E LA

WS

OF

THE

STAT

E O

F

I CER

TIFY

THAT

THE

SE

LICEN

SED

ARCH

ITECT

UND

ER

BY M

E, A

ND T

HAT

I AM

A D

ULY

DOCU

MEN

TS W

ERE

EXPI

RATIO

N DA

TE

LICEN

SE N

o.

PREP

ARED

OR

APPR

OVE

D

100

11

7.7.

20

BID DOCUMENTS

XREF

S: T

ITLEB

L

1

A2.13" = 1'-0"10

FEETSCALE3" = 1'-0"

2

A2.13/4" = 1'-0"1 0 1 2 3

FEETSCALE3/4" = 1'-0"

AutoCAD SHX Text
, BUSHEY FEIGHT MORIN ARCHITECTS, INC.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
:
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEETS
AutoCAD SHX Text
BFMARCHITECTS.COM | 301-733-5600 | FAX 301-733-5612
AutoCAD SHX Text
473 NORTH POTOMAC STREET, HAGERSTOWN, MD 21740
AutoCAD SHX Text
BFM# 20002
AutoCAD SHX Text
GCPS: ACCIDENT ELEMENTARY SCHOOL
AutoCAD SHX Text
VESTIBULE MODIFICATIONS
AutoCAD SHX Text
03.13.20
AutoCAD SHX Text
2020
AutoCAD SHX Text
A2.1
AutoCAD SHX Text
SCHEDULES &
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text
1
AutoCAD SHX Text
DET. @ NEW PERFORATED MTL PANEL
AutoCAD SHX Text
ELEV. @ NEW PERFORATED MTL PANEL
Page 6: GCPS: ACCIDENT ELEMENTARY SCHOOL VESTIBULE … · 102vestibule f1 / f2b1 / b4w5 w2w4 / w5w5 c1 v.i.f.- 103vestibule f2 b5w4 / w5w4 / w5w5 w2 c1 v.i.f. provide mtl transition strip

ALUM DOOR & FRAME

SEE

WA

LLTY

PE

SEE WALLTYPE

SEE SCHED

SEE

SC

HED

SOUND ATTENUATION

MTL STUDS

GYP. BD. (BOTH SIDES)- BOTH SIDES)

BACKER ROD & SEALNT (CONT@ PERIMETER OF FRAME

SHIM AS REQ'DALUM DOOR & FRAME

3" = 1'-0"

3

A2.2

3" = 1'-0"

4

A2.2

MTL. 'L' BEAD- CONT.@ PERIMETER OF FRAME(BOTH SIDES)

-SEE SCHED.

-SEE WALLTYPES

-SEE WALLTYPES

BLANKET

FRAME -BOTH SIDES)

BACKER ROD & SEALANT(CONT @ PERIM. OF

SOUND ATTENUATION

MTL. BOX LINTEL

GYP. BD. (BOTH SIDES)

SHIM AS REQ'D

-SEE WALLTYPES

-FILL w/ SOUND BATTS

MTL. 'L' BEAD- CONT.@ PERIMETER OF FRAME(BOTH SIDES)

MTL. STUDS @ 16" o.c.-SEE WALLTYPES

SEALANT (CONT @ PERIM.OF FRAME - BOTH SIDES)

SEALANT (CONT

JAMB ANCHORS - (3) PER SIDE

2"

SEE

SC

HED

@ PERIMETER OFFRAME - BOTH SIDES)

EXIST. 4" BRICK VENEER

3" = 1'-0"

1

A2.23" = 1'-0"

2

A2.2

DOOR-SEE SCHED.

V.I.F.

ALUM DOOR & FRAME-SEE SCHED

SEE SCHED

ALUM DOOR & FRAME-SEE SCHED

EXIST 3 5/8" MTLSTUDS @ 16" O.C.- V.I.F.

EXIST. 5/8" GYP BD.- PAINT

NEW 2x WD BLOCKINGAS REQ'D

SHIM AS REQ'DALUM. WINDOW FRAME

GLAZING

EXIST. 3 5/8" MTLSTUDS @ 16" O.C. - V.I.F.EXIST. 5/8" GYP BD.- PAINTNEW BOX BEAM LINTEL FILL w/ INSUL.SEALANT (BOTH SIDES)

ALUM. WINDOW FRAME

GLAZING

SHIM AS REQ'D

10

FEETSCALE3" = 1'-0"

7

A2.23" = 1'-0"

8

A2.23" = 1'-0"

3" = 1'-0"

5

A2.2

2"

SEE WALLTYPES

1"2"

SEE

SC

HED

SEE

WA

LLTY

PE

JAMB ANCHORS

SEE SCHED

(3 PER SIDE)SOUND ATTENUATION

MTL STUDS

GYP. BD. (BOTH SIDES)-SEE WALLTYPES

-SEE WALLTYPES

BLANKET

DOOR & FRAME-SEE SCHED

SEALANT (CONT @ PERIMETEROF FRAME - BOTH SIDES)

DOOR & FRAME-SEE SCHED

3" = 1'-0"

6

A2.2

FRAME -BOTH SIDES)

SEALANT(CONT @ PERIM. OF

SOUND ATTENUATION

MTL. BOX LINTEL

GYP. BD. (BOTH SIDES)-SEE WALLTYPES

-FILL w/ SOUND BATTS

BLANKET

3" = 1'-0"

10

A2.2

EXIST. 3 5/8" MTLSTUDS @ 16" O.C. - V.I.F.EXIST. 5/8" GYP BD.- PAINTNEW BOX BEAM LINTEL FILL w/ INSUL.

SECURE SIDE THREAT SIDE

EXIST 3 5/8" MTLSTUDS @ 16" O.C.- V.I.F.

EXIST. 5/8" GYP BD.- PAINT

NEW 2x WD BLOCKINGAS REQ'D

COUNTER BY WINDOWMANUF. - (36"x18"x1 1/2")

PASS THROUGH

WIRE PULL HANDLE

HOLE & BACKER VOICE PORT

PLUNGER LOCK & GUIDEBLOCK ASSEMBLIES

ALUMINUM BOX TRACK &VALANCE

1 3/4"x4 1/2" ALUM. TUBE

LEVEL 1 BULLETPROOFGLAZING

PORCELAIN WALLTILE TO 5'-0" A.F.F.

PORCELAIN WALLTILE TO 5'-0" A.F.F.

MTL TRIM

PORCELAIN WALLTILE TO 5'-0" A.F.F.

MTL TRIM

(E) EIFIS - V.I.F.

SHIM AS REQ'D

(E) PORCELAIN WALLTILE TO 5'-0" A.F.F.

EXIST. CONC. FLR.

CONT. BACKER ROD &SEALANT (BOTH SIDES)

ALUM. WINDOW FRAME

PERFORATED MTL PANEL

3" = 1'-0"

9

A2.2

LEVEL 1 BULLETPROOFGLAZING

SEE

WA

LLTY

PE

SEE

WA

LLTY

PE

NEW 3 5/8" MTL STUDS@ 16" O.C. - V.I.F.

EXIST. 5/8" GYP BD.- PAINT

PORCELAIN WALLTILE TO 5'-0" A.F.F.

MTL TRIM

NEW 5/8" GYP BD.- PAINT

1 3/4"x4 1/2" ALUM. TUBE

3" = 1'-0"

11

A2.2

NEW COUNTER BELOW

SECURE SIDE

THREAT SIDE

PASS THROUGH

NEW COUNTER BELOW

1 3/4"x4 1/2" ALUM. TUBENEW 3 5/8" MTL STUDS@ 16" O.C. - V.I.F.

NEW 5/8" GYP BD.- PAINTEXIST. 5/8" GYP BD.- PAINT

NEW GYP BD. - PAINT- EXTEND TO UNDERSIDEOF ROOF DECK

MTL STUDS @ 16" O.C.EXTEND STUD FRAMING TOUNDERSIDE OF ROOF DECK

MTL STUDS @ 16" O.C.EXTEND STUD FRAMING TOUNDERSIDE OF ROOF DECK

©

DRAW

ING

INTE

NT IS

TO

IN

DICA

TE G

ENER

AL

ARRA

NGEM

ENT,

DESI

GN

AND

INTE

NT O

F W

ORK

IS P

ARTL

Y DI

AGRA

MM

ATIC

. IT S

HALL

NO

T BE

SCA

LED

FOR

ROUG

H-IN

MEA

SURE

MEN

TS

OR

SERV

E AS

ERE

CTIO

N SH

OP

DRAW

ING

S.

CONT

RACT

OR

IS

RESP

ONS

IBLE

FO

R VE

RIFIC

ATIO

N O

F DI

MEN

SIO

NS

MAR

YLAN

D.TH

E LA

WS

OF

THE

STAT

E O

F

I CER

TIFY

THAT

THE

SE

LICEN

SED

ARCH

ITECT

UND

ER

BY M

E, A

ND T

HAT

I AM

A D

ULY

DOCU

MEN

TS W

ERE

EXPI

RATIO

N DA

TE

LICEN

SE N

o.

PREP

ARED

OR

APPR

OVE

D

100

11

7.7.

20

BID DOCUMENTS

XREF

S: T

ITLEB

L

AutoCAD SHX Text
ALUM JAMB DETAIL @ INTERIOR STUD WALL
AutoCAD SHX Text
ALUM HEAD DETAIL @ INTERIOR STUD WALL
AutoCAD SHX Text
HM JAMB DETAIL @ EXTERIOR MASONRY WALL
AutoCAD SHX Text
HM HEAD DETAIL @ EXTERIOR WALL
AutoCAD SHX Text
SILL DTL. @ INTERIOR WINDOW
AutoCAD SHX Text
head DTL. @ INTERIOR WINDOW
AutoCAD SHX Text
HM JAMB DETAIL @ INTERIOR GYP. BD. WALL
AutoCAD SHX Text
HM HEAD DETAIL @ INTERIOR GYP. BD. WALL
AutoCAD SHX Text
DETAIL @ SECURITY WINDOW
AutoCAD SHX Text
SILL DETAIL @ INTERIOR WINDOW
AutoCAD SHX Text
DETAIL @ SECURITY WINDOW JAMB
AutoCAD SHX Text
, BUSHEY FEIGHT MORIN ARCHITECTS, INC.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
:
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEETS
AutoCAD SHX Text
BFMARCHITECTS.COM | 301-733-5600 | FAX 301-733-5612
AutoCAD SHX Text
473 NORTH POTOMAC STREET, HAGERSTOWN, MD 21740
AutoCAD SHX Text
BFM# 20002
AutoCAD SHX Text
GCPS: ACCIDENT ELEMENTARY SCHOOL
AutoCAD SHX Text
VESTIBULE MODIFICATIONS
AutoCAD SHX Text
03.13.20
AutoCAD SHX Text
2020
AutoCAD SHX Text
A2.2
AutoCAD SHX Text
DOOR & WINDOW
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text
1
Page 7: GCPS: ACCIDENT ELEMENTARY SCHOOL VESTIBULE … · 102vestibule f1 / f2b1 / b4w5 w2w4 / w5w5 c1 v.i.f.- 103vestibule f2 b5w4 / w5w4 / w5w5 w2 c1 v.i.f. provide mtl transition strip

W2W2

NEW PORCELAIN WALLTILE TO MATCH EXIST.

EXIST. PORCELAINWALL TILE

NEW H.M. WINDOW- SEE WINDOW TYPES

NEW GYP BD. - PAINTEXIST. GYP BD.NEW PERFORATED MTL

PANEL - SEE DTLS. 1-2/A2.1

(E)

106

NEW H.M. FRAME &RELOCATED DOOR- SEE SCHED

(E) CASEWORK RELOCATEDCASEWORK

EXIST. DOOR &FRAME TO REMAIN

105ARELOCATEDCASEWORK

NEW H.M. FRAME &RELOCATED DOOR- SEE SCHED

NEW COUNTER

VINYL BASE

RELOCATEDCLOCK

RELOCATED MAILBOXES- VERIFY DIMENSIONS IN FIELD

RELOCATEDREFRIGERATOR

EXIST. SHELF TO REMAIN

RELOCATED COPIER

EXIST. WINDOW

EXIST. WINDOW

RELOCATED CASEWORK w/ NEWCOUNTER & BACK SPLASH- COUNTER SIM TO DTL 6/A6.1

ELEVATION CELEVATION BELEVATION A

(E) PRIMEX& SHELF

RELOCATEDCASEWORK

1'-8"

INSTALL NEW COUNTER& BACK SPLASH - SIMTO DTL 6/A6.1

W2

W3

NEW H.M. WINDOW- SEE WINDOW TYPES

OPEN

EXIST. CASEWORK TOREMAIN w/ NEW COUNTERTOP - BASE BID - COUNTERSIM TO DTL 6/A6.1

OPEN 32"

42" -

V.I.F

.

1 1/2

"

42"

3 MM PVC EDGEBANDING

MIN 1/4" PREFIN.HARDBONDED BACK

MOUNTING RAILS

3/4" PARTICLE BD TOPw/ P-LAM FINISH

FIN. FLR.ELEV.

PLASTIC LAMINATE ON 3/4"MOISTURE RESISTANT PARTICLEBOARD & 3/4" BUILD-UP

1 1/2" = 1'-0"SCALE FEET1 0 1

2x WD BLOCKING

1/2" PLYWOOD SHEATHING

3/4" PARTICLE BD w/MELAMINE FINISH

6

A6.11 1/2" = 1'-0"

NEW DUPLEX RECEPTACLE

NEW DATA PORT

GROMMETED WIRE DROP

OPEN FILESFILESFILES

W3

NEW H.M. WINDOW- SEE WINDOW TYPES

6A6.1

NEW CASEWORK &COUNTER PER ADD ALT.

W2 OPEN

32"42

"

©

DRAW

ING

INTE

NT IS

TO

IN

DICA

TE G

ENER

AL

ARRA

NGEM

ENT,

DESI

GN

AND

INTE

NT O

F W

ORK

IS P

ARTL

Y DI

AGRA

MM

ATIC

. IT S

HALL

NO

T BE

SCA

LED

FOR

ROUG

H-IN

MEA

SURE

MEN

TS

OR

SERV

E AS

ERE

CTIO

N SH

OP

DRAW

ING

S.

CONT

RACT

OR

IS

RESP

ONS

IBLE

FO

R VE

RIFIC

ATIO

N O

F DI

MEN

SIO

NS

MAR

YLAN

D.TH

E LA

WS

OF

THE

STAT

E O

F

I CER

TIFY

THAT

THE

SE

LICEN

SED

ARCH

ITECT

UND

ER

BY M

E, A

ND T

HAT

I AM

A D

ULY

DOCU

MEN

TS W

ERE

EXPI

RATIO

N DA

TE

LICEN

SE N

o.

PREP

ARED

OR

APPR

OVE

D

100

11

7.7.

20

BID DOCUMENTS

XREF

S: T

ITLEB

L

2 0 2 4 6 8 101/4" = 1'-0"

SCALE FEET

1

A6.11/4" = 1'-0"

2

A6.11/4" = 1'-0"

3

A6.11/4" = 1'-0"

4

A6.11/4" = 1'-0"

AutoCAD SHX Text
DET @ NEW COUNTER (ALTERNATE)
AutoCAD SHX Text
, BUSHEY FEIGHT MORIN ARCHITECTS, INC.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
:
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEETS
AutoCAD SHX Text
BFMARCHITECTS.COM | 301-733-5600 | FAX 301-733-5612
AutoCAD SHX Text
473 NORTH POTOMAC STREET, HAGERSTOWN, MD 21740
AutoCAD SHX Text
BFM# 20002
AutoCAD SHX Text
GCPS: ACCIDENT ELEMENTARY SCHOOL
AutoCAD SHX Text
VESTIBULE MODIFICATIONS
AutoCAD SHX Text
03.13.20
AutoCAD SHX Text
2020
AutoCAD SHX Text
A6.1
AutoCAD SHX Text
INTERIOR
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
1
AutoCAD SHX Text
INTERIOR ELEVATION - 104 LOBBY
AutoCAD SHX Text
INTERIOR ELEVATION - (E) WORK / STOR.
AutoCAD SHX Text
INTERIOR ELEVATION - (E) GENERAL OFF. (BASE BID)
AutoCAD SHX Text
INTERIOR ELEVATION - (E) GENERAL OFF. (ADD ALT.)
Page 8: GCPS: ACCIDENT ELEMENTARY SCHOOL VESTIBULE … · 102vestibule f1 / f2b1 / b4w5 w2w4 / w5w5 c1 v.i.f.- 103vestibule f2 b5w4 / w5w4 / w5w5 w2 c1 v.i.f. provide mtl transition strip

CAFETERIA(E)

VAULT(E)

GENERAL OFFICE(E)

HEALTH107

VESTIBULE101

VESTIBULE101

VESTIBULE102

VESTIBULE103

LOBBY104

TEACHER LOUNGE(E)

MEN(E)WOMEN(E)

WORK / STORAGE106 PRINCIPAL105

CONF. ROOM(E)

RELOCATED EXIT SIGN

NEW EXIT SIGN

RELOCATEDLIGHT FIXTURE

RELOCATEDLIGHT FIXTURE

RELOCATEDSPEAKER

REINSTALL EXIST. SOFFIT ASREQUIRED DUE TO WORK REMOVINGAND INSTALLING NEW STOREFRONT ,& EXTENDING STUDS TO ROOF DECK

RELOCATEDLIGHT FIXTURE

EXIST. LED LIGHTFIXTURES - V.I.F.

CORRIDOR(E)

ALTERNATE AREA- SEE 2/A8.1

EXHAUST

RETURN

SUPPLY

LINEAR SUPPLY GRILL

GYP. BD. BULKHEAD

GYP. BD. CEILING

DUCT MOUNTEDSUPPLY GRILL

NEW 2' x 4' ACOUSTICALTILE AND GRID - HATCHED

FLUORESCENT RECESSEDLIGHT FIXTURE (EXISTING)

FLUORESCENT RECESSEDLIGHT FIXTURE (NEW)

12" Ø TRACK MOUNTEDPENDANT LIGHT FIXTURE

4' SURFACE MOUNTEDLIGHT FIXTURE

4' STRIP LIGHT FIXTURESUSPENDED ABOVETRANSLUCENT PANELS

DOWN LIGHT

1x2 WALL MOUNTEDLIGHT FIXTURE

EXIT SIGN - SINGLE SIDEDEXIT SIGN - DOUBLE SIDED

12" Ø DECORATIVE PENDANTLIGHT FIXTURE

SOFFIT PANELS

WALL MOUNTED LIGHT

EMERGENCY LIGHTING

(E) 2' x 4' ACOUSTICALTILE AND GRID

(E) DOWN LIGHT

4' SURFACE MOUNTEDLIGHT FIXTURE (EMERGENCY)

SPEAKERSPRINKLER HEAD (EXISTING)

LIGHT FIXTURE SCHEDULEMETALUX MODEL No.24GR-LD5-38-F1-UNV-L835-CD1-U (2x2)

WORK / STORAGE106

CONF. ROOM

STORAGE106

©

DRAW

ING

INTE

NT IS

TO

IN

DICA

TE G

ENER

AL

ARRA

NGEM

ENT,

DESI

GN

AND

INTE

NT O

F W

ORK

IS P

ARTL

Y DI

AGRA

MM

ATIC

. IT S

HALL

NO

T BE

SCA

LED

FOR

ROUG

H-IN

MEA

SURE

MEN

TS

OR

SERV

E AS

ERE

CTIO

N SH

OP

DRAW

ING

S.

CONT

RACT

OR

IS

RESP

ONS

IBLE

FO

R VE

RIFIC

ATIO

N O

F DI

MEN

SIO

NS

MAR

YLAN

D.TH

E LA

WS

OF

THE

STAT

E O

F

I CER

TIFY

THAT

THE

SE

LICEN

SED

ARCH

ITECT

UND

ER

BY M

E, A

ND T

HAT

I AM

A D

ULY

DOCU

MEN

TS W

ERE

EXPI

RATIO

N DA

TE

LICEN

SE N

o.

PREP

ARED

OR

APPR

OVE

D

100

11

7.7.

20

BID DOCUMENTS

XREF

S: T

ITLEB

L

2 0 2 4 6 8 101/4" = 1'-0"

SCALE FEET

1

A8.11/4" = 1'-0"

2

A8.11/4" = 1'-0"

KEY PLANNO SCALE

AREA OF WORK

KEY PLANNO SCALE

AREA OF WORK

AutoCAD SHX Text
%%uLIGHTING LEGEND
AutoCAD SHX Text
%%uMECH. LEGEND
AutoCAD SHX Text
%%UCEILING TYPES
AutoCAD SHX Text
, BUSHEY FEIGHT MORIN ARCHITECTS, INC.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
:
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEETS
AutoCAD SHX Text
BFMARCHITECTS.COM | 301-733-5600 | FAX 301-733-5612
AutoCAD SHX Text
473 NORTH POTOMAC STREET, HAGERSTOWN, MD 21740
AutoCAD SHX Text
BFM# 20002
AutoCAD SHX Text
GCPS: ACCIDENT ELEMENTARY SCHOOL
AutoCAD SHX Text
VESTIBULE MODIFICATIONS
AutoCAD SHX Text
03.13.20
AutoCAD SHX Text
2020
AutoCAD SHX Text
A8.1
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
PLAN
AutoCAD SHX Text
1
AutoCAD SHX Text
NEW CEILING PLAN : BASE BID
AutoCAD SHX Text
NEW CEILING PLAN : ALTERNATE
Page 9: GCPS: ACCIDENT ELEMENTARY SCHOOL VESTIBULE … · 102vestibule f1 / f2b1 / b4w5 w2w4 / w5w5 c1 v.i.f.- 103vestibule f2 b5w4 / w5w4 / w5w5 w2 c1 v.i.f. provide mtl transition strip

WOMEN(E) MEN(E)

CAFETERIA(E)

TEACHER LOUNGE(E)

VAULT(E)

SD

D

S

D

S

D

S

SD

S D

2

2

S

1

1

1

1

1

1

2

2

3

S24

5

CONF. ROOM(E)

6

C

CORRIDOR(E)S

(E) SECURITY CAMERAMOUNTED ON BULKHEAD

D

ADA

S

T

7

CR

(E) PULL STATIONw/ STROBE ABOVE

S6

3

3

ELECTRICAL DEMOLITION NOTES

REMOVE (E) DUPLEX RECEPTACLE- PATCH ANDREPAIR ADJACENT FINISHES AS REQUIRED

REMOVE (E) DATA CONNECTION - PATCH ANDREPAIR ADJACENT FINISHES AS REQUIRED

REMOVE (E) QUAD RECEPTACLE - PATCH ANDREPAIR ADJACENT FINISHES AS REQUIRED

RELOCATE (E) SWITCH ABOVE (E) COUNTER

REMOVE & RELOCATE (E) CLOCK & ASSOCIATEDELECTRICAL CONNECTIONS

REMOVE & RELOCATE (E) SWITCH - PATCH &REPAIR ADJACENT FINISHES AS REQUIRED

REMOVE & RELOCATE (E) A-PHONE - PATCH &REPAIR ADJACENT FINISHES AS REQUIRED

1

2

3

4

5

6

7

ELECTRICAL LEGENDNEW DUPLEX RECEPTACLE, SPEC GRADE,TAMPER RESISTANT, 1PH, 125V. GROUNDINGTYPE, MTD 18" AFF UNLESS OTHERWISE NOTED

SWITCH, SPECIFICATION GRADE, SINGLE POLE15A, MOUNTED 48" AFF

S

DOUBLE SWITCH, SPEC GRADE, 15A, MOUNTED48" AFF

S2

D DATA CONNECTION

PHONE CONNECTION

C CABLE CONNECTION

GENERAL ELECTRICAL NOTES

1. GENERAL NOTES ON THIS DRAWING SHALL APPLY TO ALLELECTRICAL DRAWINGS FOR THIS PROJECT. CONTRACTOR SHALLREAD ALL GENERAL NOTES PRIOR TO BEGINNING ANY WORK

2. ANY MATERIALS AND DEVICE NOT SPECIFICALLY MENTIONED INTHE SPECIFICATIONS ORE INDICATED ON THE DRAWINGS THAT AREREQUIRED FOR A COMPLETE OPERATING SYSTEM INSTALLATIONSHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONALCOST TO THE OWNER

3. WHERE THE TERM 'PROVIDE' IS USED ON THESE DRAWINGS, ITSHALL BE DEFINED AS FOLLOWS, FURNISH, INSTALL AND MAKEALL FINAL CONNECTIONS FOR THE EQUIPMENT INDICATED

4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THEEXACT ROUTING OF WIRING AND CONDUITS

5. UNLESS OTHERWISE NOTED, MOUNTING HEIGHTS FOR DEVICE ARETO TOP OF BOX

6. WHERE APPLICABLE, MOUNTING HEIGHTS SHALL CONFORM TOHANDICAP HEIGHT

7. ALL INSTALLATIONS SHALL BE INSTALLED CONCEALED, IN THEEVENT EXISTING CMU WALLS IN FINISH SPACES PROHIBITCONCEALMENT THE INSTALLATIONS SHALL BE SURFACEMOUNTED. UTILIZE SURFACE MOUNTED EMT CONDUIT WITHAPPROPRIATE SURFACE BOXES. PATCH, REPAIR AND PAINT WALLOR ADJACENT SURFACES DAMAGED WHERE EXISTING DEVICESARE REMOVED TO MATCH SURROUNDINGS

8. SEE CONTRACTOR SPECIFICATIONS FOR CUTTING AND PATCHINGREQUIREMENTS OF EXISTING WALLS AND FLOORS

9. ALL DIMENSIONS AND EXISTING CONDITIONS SHALL BE CHECKEDAND VERIFIED AT THE SITE BY THE CONTRACTOR PRIOR TO BIDS

10. WHERE EXISTING DEVICES ARE DESIGNATED TO BE REMOVED. THECONTRACTOR SHALL REMOVE THE DEVICES AND ALLASSOCIATED WIRING BACK TO THE SERVICE POINT.

11. DRAWINGS ARE DIAGRAMMATIC AND MAY NOT INDICATE ALLDEVICES AND APPURTENANCES NEEDED FOR A COMPLETESYSTEM. THE CONTRACTOR SHALL REFER TO THE SPECIFICATIONSFOR A COMPLETE DESCRIPTION OF THE SYSTEM

12. IT SHALL BE THE CONTRACTORS RESPONSIBILITY FOR REMOVINGCEILING TILE DURING THE COURSE OF WORK. UPON COMPLETIONALL CEILING TILES SHALL BE PLACED BACK WITHIN GRID SYSTEM.ANY TILES DAMAGED DURING CONSTRUCTION SHALL BEREPLACED IN KIND AT NO ADDITIONAL COST .

13. CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALLEXISTING EQUIPMENT AND UTILITIES BEFORE COMMENCING WORK

©

DRAW

ING

INTE

NT IS

TO

IN

DICA

TE G

ENER

AL

ARRA

NGEM

ENT,

DESI

GN

AND

INTE

NT O

F W

ORK

IS P

ARTL

Y DI

AGRA

MM

ATIC

. IT S

HALL

NO

T BE

SCA

LED

FOR

ROUG

H-IN

MEA

SURE

MEN

TS

OR

SERV

E AS

ERE

CTIO

N SH

OP

DRAW

ING

S.

CONT

RACT

OR

IS

RESP

ONS

IBLE

FO

R VE

RIFIC

ATIO

N O

F DI

MEN

SIO

NS

MAR

YLAN

D.TH

E LA

WS

OF

THE

STAT

E O

F

I CER

TIFY

THAT

THE

SE

LICEN

SED

ARCH

ITECT

UND

ER

BY M

E, A

ND T

HAT

I AM

A D

ULY

DOCU

MEN

TS W

ERE

EXPI

RATIO

N DA

TE

LICEN

SE N

o.

PREP

ARED

OR

APPR

OVE

D

100

11

7.7.

20

BID DOCUMENTS

XREF

S: T

ITLEB

L

2 0 2 4 6 8 101/4" = 1'-0"

SCALE FEET

1

E1.11/4" = 1'-0" KEY PLANNO SCALE

AREA OF WORK

AutoCAD SHX Text
, BUSHEY FEIGHT MORIN ARCHITECTS, INC.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
:
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEETS
AutoCAD SHX Text
BFMARCHITECTS.COM | 301-733-5600 | FAX 301-733-5612
AutoCAD SHX Text
473 NORTH POTOMAC STREET, HAGERSTOWN, MD 21740
AutoCAD SHX Text
BFM# 20002
AutoCAD SHX Text
GCPS: ACCIDENT ELEMENTARY SCHOOL
AutoCAD SHX Text
VESTIBULE MODIFICATIONS
AutoCAD SHX Text
03.13.20
AutoCAD SHX Text
2020
AutoCAD SHX Text
E1.1
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
DEMO PLAN
AutoCAD SHX Text
1
AutoCAD SHX Text
PARTIAL ELECTRICAL DEMO PLAN
Page 10: GCPS: ACCIDENT ELEMENTARY SCHOOL VESTIBULE … · 102vestibule f1 / f2b1 / b4w5 w2w4 / w5w5 c1 v.i.f.- 103vestibule f2 b5w4 / w5w4 / w5w5 w2 c1 v.i.f. provide mtl transition strip

WOMEN(E) MEN(E)

CAFETERIA(E)

TEACHER LOUNGE(E)

VAULT(E)

VESTIBULE101

VESTIBULE103

LOBBY104

PRINCIPA.L105

WORK / STORAGE106

HEALTH107

D

S

D

S

SD

S D

S

D

NEW DATA CONNECTIONSAS REQ'D FOR PRINTER

RELOCATED CLOCK &ASSOCIATED CONNECTIONS

D

NEW DATA CONNECTION

NEW DUPLEXRECEPTACLE

S2

RELOCATED DOUBLE SWITCH TOABOVE (E) COUNTER HEIGHT

CONF. ROOM(E)

S

RELOCATED SWITCH

C

GENERAL OFFICE108

CORRIDOR(E)S

(E) SECURITY CAMERAMOUNTED ON BULKHEAD

NEW 2x2 LIGHT FIXTURE-SEE CLG PLAN

NEW PHONE CNXAS REQ'D

NEW DUPLEXRECEPTACLE

(E) CLOCK

D

ADA

ADA

ADA

ADA

ADA

ADA

CR

ADA

S

RELOCATEDA-PHONE

NEW KNOXBOX

T

ADA

CR

(E) PULL STATIONw/ STROBE ABOVE

S

RELOCATED SWITCH- TIE INTO EXIST LIGHTING

3

VESTIBULE102

3

3

TIE INTO EXIST LIGHTS IN108 GENERAL OFFICE

S2

RELOCATED SWITCH- TIE INTO EXIST LIGHTING

3

ELECTRICAL LEGENDNEW DUPLEX RECEPTACLE, SPEC GRADE,TAMPER RESISTANT, 1PH, 125V. GROUNDINGTYPE, MTD 18" AFF UNLESS OTHERWISE NOTED

SWITCH, SPECIFICATION GRADE, SINGLE POLE15A, MOUNTED 48" AFF

S

DOUBLE SWITCH, SPEC GRADE, 15A, MOUNTED48" AFF

S2

D DATA CONNECTION

PHONE CONNECTION

C CABLE CONNECTION

GENERAL ELECTRICAL NOTES

1. GENERAL NOTES ON THIS DRAWING SHALL APPLY TO ALLELECTRICAL DRAWINGS FOR THIS PROJECT. CONTRACTOR SHALLREAD ALL GENERAL NOTES PRIOR TO BEGINNING ANY WORK

2. ANY MATERIALS AND DEVICE NOT SPECIFICALLY MENTIONED INTHE SPECIFICATIONS ORE INDICATED ON THE DRAWINGS THAT AREREQUIRED FOR A COMPLETE OPERATING SYSTEM INSTALLATIONSHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONALCOST TO THE OWNER

3. WHERE THE TERM 'PROVIDE' IS USED ON THESE DRAWINGS, ITSHALL BE DEFINED AS FOLLOWS, FURNISH, INSTALL AND MAKEALL FINAL CONNECTIONS FOR THE EQUIPMENT INDICATED

4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THEEXACT ROUTING OF WIRING AND CONDUITS

5. UNLESS OTHERWISE NOTED, MOUNTING HEIGHTS FOR DEVICE ARETO TOP OF BOX

6. WHERE APPLICABLE, MOUNTING HEIGHTS SHALL CONFORM TOHANDICAP HEIGHT

7. ALL INSTALLATIONS SHALL BE INSTALLED CONCEALED, IN THEEVENT EXISTING CMU WALLS IN FINISH SPACES PROHIBITCONCEALMENT THE INSTALLATIONS SHALL BE SURFACEMOUNTED. UTILIZE SURFACE MOUNTED EMT CONDUIT WITHAPPROPRIATE SURFACE BOXES. PATCH, REPAIR AND PAINT WALLOR ADJACENT SURFACES DAMAGED WHERE EXISTING DEVICESARE REMOVED TO MATCH SURROUNDINGS

8. SEE CONTRACTOR SPECIFICATIONS FOR CUTTING AND PATCHINGREQUIREMENTS OF EXISTING WALLS AND FLOORS

9. ALL DIMENSIONS AND EXISTING CONDITIONS SHALL BE CHECKEDAND VERIFIED AT THE SITE BY THE CONTRACTOR PRIOR TO BIDS

10. WHERE EXISTING DEVICES ARE DESIGNATED TO BE REMOVED. THECONTRACTOR SHALL REMOVE THE DEVICES AND ALLASSOCIATED WIRING BACK TO THE SERVICE POINT.

11. DRAWINGS ARE DIAGRAMMATIC AND MAY NOT INDICATE ALLDEVICES AND APPURTENANCES NEEDED FOR A COMPLETESYSTEM. THE CONTRACTOR SHALL REFER TO THE SPECIFICATIONSFOR A COMPLETE DESCRIPTION OF THE SYSTEM

12. IT SHALL BE THE CONTRACTORS RESPONSIBILITY FOR REMOVINGCEILING TILE DURING THE COURSE OF WORK. UPON COMPLETIONALL CEILING TILES SHALL BE PLACED BACK WITHIN GRID SYSTEM.ANY TILES DAMAGED DURING CONSTRUCTION SHALL BEREPLACED IN KIND AT NO ADDITIONAL COST .

13. CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALLEXISTING EQUIPMENT AND UTILITIES BEFORE COMMENCING WORK

ELECTRICAL REQUIREMENTS FOR MECHANICAL EQUIPMENT

1. ALL CONTROL WIRING (LINE VOLTAGE AND OR LOW VOLTAGE) FOR MECHANICALEQUIPMENT PROVIDED UNDER DIVISION 23, SHALL BE FURNISHED AND INSTALLED UNDERDIVISION 23. WIRING FROM POWER SOURCE TO ALL CONTROL PANELS, DDC CONTROLPANELS, STARTERS, OPERATOR WORK STATIONS (PC'S, PRINTERS, MONITORS, ANDOTHER WORK STATION EQUIPMENT) AND OTHER CONTROL EQUIPMENT REQUIRED FOR ACOMPLETE AND OPERABLE CONTROL SYSTEM SERVING MECHANICAL EQUIPMENTPROVIDED UNDER DIVISION 23, SHALL BE FURNISHED AND INSTALLED UNDER DIVISION 23

2. ALL WIRING FROM CONTROL PANELS TO CONTROL DEVICES FOR MECHANICALEQUIPMENT PROVIDED UNDER DIVISION 23 SHALL BE FURNISHED AND INSTALLED UNDERDIVISION 23. ALL CONTROL WIRE AND CONDUIT SHALL COMPLY WITH THE NATIONALELECTRIC CODE AND DIVISION 26 OF THE SPECIFICATIONS. ALL CONTROL WIRING SHALLBE IN CONDUIT.

3. UNLESS OTHERWISE NOTED. ALL TEMPERATURE CONTROL DEVICES, INSTALLED PILOTDEVICES, AND ALL ASSOCIATED PILOT CONTROL EQUIPMENT, FOR ALL EQUIPMENTPROVIDED UNDER DIVISION 23, SHALL BE FURNISHED AND INSTALLED UNDER DIVISION 23

4. ELECTRICAL CONTROL WIRING FOR CONNECTION OF TEMPERATURE CONTROLLERS, PUSHBUTTONS, INTERLOCKS IN MOTORE CONTROLLERS, PNEUMATIC SWITCHES AND LIKEITEMS IS SPECIFIED UNDER THE CONTROL SECTIONS IN DIVISION 23 AND INSTALLEDUNDER DIVISION 23

STOR.109

SNEW SWITCH

TIE INTO EXIST LIGHTS IN108 GENERAL OFFICE

3S3

©

DRAW

ING

INTE

NT IS

TO

IN

DICA

TE G

ENER

AL

ARRA

NGEM

ENT,

DESI

GN

AND

INTE

NT O

F W

ORK

IS P

ARTL

Y DI

AGRA

MM

ATIC

. IT S

HALL

NO

T BE

SCA

LED

FOR

ROUG

H-IN

MEA

SURE

MEN

TS

OR

SERV

E AS

ERE

CTIO

N SH

OP

DRAW

ING

S.

CONT

RACT

OR

IS

RESP

ONS

IBLE

FO

R VE

RIFIC

ATIO

N O

F DI

MEN

SIO

NS

MAR

YLAN

D.TH

E LA

WS

OF

THE

STAT

E O

F

I CER

TIFY

THAT

THE

SE

LICEN

SED

ARCH

ITECT

UND

ER

BY M

E, A

ND T

HAT

I AM

A D

ULY

DOCU

MEN

TS W

ERE

EXPI

RATIO

N DA

TE

LICEN

SE N

o.

PREP

ARED

OR

APPR

OVE

D

100

11

7.7.

20

BID DOCUMENTS

XREF

S: T

ITLEB

L

2 0 2 4 6 8 101/4" = 1'-0"

SCALE FEET

1

E1.21/4" = 1'-0" KEY PLANNO SCALE

AREA OF WORK

2

E1.21/4" = 1'-0"

AutoCAD SHX Text
, BUSHEY FEIGHT MORIN ARCHITECTS, INC.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
:
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEETS
AutoCAD SHX Text
BFMARCHITECTS.COM | 301-733-5600 | FAX 301-733-5612
AutoCAD SHX Text
473 NORTH POTOMAC STREET, HAGERSTOWN, MD 21740
AutoCAD SHX Text
BFM# 20002
AutoCAD SHX Text
GCPS: ACCIDENT ELEMENTARY SCHOOL
AutoCAD SHX Text
VESTIBULE MODIFICATIONS
AutoCAD SHX Text
03.13.20
AutoCAD SHX Text
2020
AutoCAD SHX Text
E1.2
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
PLAN - NEW
AutoCAD SHX Text
1
AutoCAD SHX Text
NEW ELECTRICAL PLAN : BASE BID
AutoCAD SHX Text
NEW ELECTRICAL PLAN : ALTERNATE