www.gbc.com.tw [email protected] E No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C. A +886 3 577 9221 T +886 3 577 9227 F AUROC FIBROSIS STAGES BioFibroScore ® >0.95 >0.95 >0.95 >0.95 F≥1 F≥2 F≥3 F≥4 Blood sampling method Less expensive and no painful procedures Patent pending with 3 biomarkers and an algorithm to generate results in 4 different stages Validated with 500+ samples Hepatitis B Hepatitis C Alcoholic Liver Disease Metabolic / Non-Alcoholic Fatty Liver Disease BioFibroScore ® platform shows an excellent accuracy (>0.95) in all stages, especially in early stages. The technology has been offered as a service bundling as Liver20 TM . ® ELISA Kits & Instruments, RT-PCR & instruments, Raw Materials, Labware, & CLIA (new)

GB_DM_Single Page

Embed Size (px)

DESCRIPTION

 

Citation preview

Page 1: GB_DM_Single Page

[email protected] E

No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C.A

+886 3 577 9221T +886 3 577 9227F

AUROCFIBROSIS STAGES

BioFibroScore® >0.95 >0.95 >0.95 >0.95

F≥1 F≥2 F≥3 F≥4

Blood sampling methodLess expensive and no painful proceduresPatent pending with 3 biomarkers and an algorithm to generate results in 4 different stagesValidated with 500+ samples

Hepatitis BHepatitis CAlcoholic Liver DiseaseMetabolic / Non-Alcoholic Fatty Liver Disease

BioFibroScore® platform shows an excellent accuracy (>0.95) in all stages, especially in early stages.The technology has been offered as a service bundling as Liver20TM.

®

ELISA Kits & Instruments, RT-PCR & instruments, Raw Materials, Labware, & CLIA (new)

Page 2: GB_DM_Single Page
Page 3: GB_DM_Single Page

Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer

GB WatoTM

An Automatic ELISA Plate Washer

Specifically designed Manifold assembly to prevent any scratching on bottom of well

Programmable soak time, wash cycles and dispensing volume

Onboard two-plate incubator at 37�with programmable timer

Waste bottle full warning with audible alarm

Built-in stabilizer

Continuous aspiration to prevent overflow

Removable manifold

Ability to wash single strip of 8 wells

PRODUCT HIGHLIGHTS

FOCUSING ON YOUR NEEDS

Various types of plate can be supported and are easily

inter-changeable in the plate carrier to maximize the

washing performance. GB WatoTM is an automatic

ELISA Strip / Plate Washer with built-in incubator &

programmable timer.

Page 4: GB_DM_Single Page

Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer

ORDERING INFORMATIONCatalog No. S00346

Description GB WatoTM

Package 1 unit

GB WATOTM TECHNICAL SPECIFICATION

Manifold 8 Way Manifold Dispensing

Dispensing Method : Specially designed Peristaltic PumpVolume : 300 to 400 µL in steps of 50 µL

AspiratingMethod : Continuous through diaphragm pump while Dispensing hence preventing overflowResidual Volume : < 5 µL

Waste Bottle One (Capacity 2 liters) with audible alarm when bottle is completely filled in with waste solution

Wash Bottle One (Capacity 2 liters)

Rinse Bottle One (Capacity 2 liters)

Display Single line Backlit LCD with 16 characters

Liquid contact materials Silicon, Stainless steel, derline

Memory 8 KB Non volatile RAM battery back up suppor ting 35 open channels

Washing Method Longwash, Shortwash Rinsing, Priming

Incubator For Two ELISA Plates, 37º C

Timer

Power

Operating Position

Operating Conditions

Storage Conditions

Enclosure

Size (cm)

Weight

Individually Programmable

Wattage : 50 WattsVoltage : 115 - 230 Volts ± 10%, 50 /60 Hz.

On horizontal, rigid, flat and vibration free surface

Temperature : + 18º C to 35º C Humidity : up to 85 %

Temperature : - 10º C to 60º C Humidity : up to 85 %

ABS Fire retardant

35 X 35 X 13 (lxwxh)

6 Kgs

www.gbc.com.tw

+886 3 577 9221T

[email protected] E

No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C.A

+886 3 577 9227F

2013.Mar.

Page 5: GB_DM_Single Page

Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer

GB TempCardTM

Temperature Recorder

Alert indicator – indicates if readings are outside of preset limits

OK indicator indicates if still recording and if readings within configured limits

Credit card sized case – thin enough to be easily mailed “letter rate”.

Real time clock records time & temperature simultaneously

Highly reliable and accurate

Pre-Start Logging - Configurable to record even when "start" button has not been pressed

High performance at lower cost

Credit Card sized design - easy to carry and transport

Re-calibration function available

PRODUCT HIGHLIGHTS

MADE SPECIALLY FOR YOU

GB TempCardTM Temperature Recorder incorporates an innovative

temperature sensor built inside this portable device. GB TempCardTM

has been designed to endure hard damages yet still provide a fast

reaction time.

USER-FRIENDLY INTERFACE

GB TempCardTM comes with a great user-friendly interface software, TempCardTM Analyzer, for

reading and analyzing collected data. GB TempCardTM Analyzer provides functions including

delayed start, sampling interval, number of readings, continuous or fixed number of readings

and ALERT function setup.

Data recorded can be downloaded or exported in excel.

Page 6: GB_DM_Single Page

www.gbc.com.tw

+886 3 577 9221T

[email protected] E

No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C.A

+886 3 577 9227F

2013/Mar.

Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer

ORDERING INFORMATIONCatalog No. S00351

Description GB TempCardTM

Package 1 unit

GB TEMPCARDTM TECHNICAL SPECIFICATION

Capacity 8000 temperature readings (16Kbytes memory)

Frequency Adjustable, 30 seconds to several hours

Download TimeTypically with full memory in less than 5 seconds depending on computer or readout device used

Environmental IP65

Battery 3V Lithium

Life 2~3 years on regular uses

Real Time Clock

Installed with Real Time Clock.Rated accuracy ±25ppm @ 25°C (equiv to 2.5 seconds/day) Rated temperature coefficient is -0.034±0.006ppm/°C (i.e typically +/- 0.00294seconds/day/°C)

Dimension 86mm (L) x 55mm (W) x 8.6mm (H)

Weight 35g

Case Material Polycarbonate

EMC Compliance Tested and complies with EC EMC directives (EN 50081-1:1992 & EN 61000-6-1:2001)

EN12380 Compliance Tested and complies to EN12830:1999 for transport, storage and distribution of chilled, frozen, deep frozen, quick-frozen food and others

Page 7: GB_DM_Single Page

Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer

GB RitoTM

An Automatic ELISA Plate Reader

Built-in shaker with variable speed & duration

Results printing in matrix mode format

Option to run multiple blank in cut-off mode

Bichromatic readings

Ability to read from any strip in a single plate

Extensive curve plotting

Robust system with built-in stabilizer

PRODUCT HIGHLIGHTS

FOCUSING ON YOUR NEEDS

GB RitoTM is an automatic ELISA Plate Reader with

user-friendly touch interface and software. GB RitoTM

can be used for all routine immunoassays, biochemi-

cals, hormones, and drug levels. It is an economical

reliable and high precision instrument.

Page 8: GB_DM_Single Page

www.gbc.com.tw

+886 3 577 9221T

[email protected] E

No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C.A

+886 3 577 9227F

2013.Mar.

Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer

ORDERING INFORMATIONCatalog No. S00345

Description GB RitoTM

Package 1 unit

GB RITOTM TECHNICAL SPECIFICATION

Interface TOUCH PANEL / KEYPAD

Linear measurement range 0.000 to 3.000 Absorbance Units(A)

Photometirc Accuracy ± 2% or 0.005 whichever is higher, from 0 to 1.5 A± 3% from 1.5 A to 3.0 A

Drift <0.005 A/hr

Photometric Linearity 2.5 A

Optical measurement 8 Channel

Filters

Type of Filter : Narrow band InterferenceWave Length : 405nm, 450nm, 492nm, 560nm, 630nmHalf Bandwidth : 10 nm ± 2nmSelection : Automatic by Stepper Motor

Light Source Tungsten halogen lamp

Warm up time 90 seconds (built - in)

Display 6” Graphics LCD, Negative Blue, STN

Curve Plotting Graphical Representation on Printer

Plate Carrier Movement

Printer

Memory

Analysis Mode

RS232 Serial Port

Power

Operating Position

Operating Conditions

Storage Conditions

Enclosure

Size (cm)

Weight

Precisely through the stepper motor

Built in Thermal Printer 52 columns

64 KB Non Volatile RAM Battery backupsuppor ting125 open channels

Absorbance Cut - offMulti - Standard % Absorbance

2400 baud, 8 data, 1 stop, no parity bits / USB

Wattage : 50 WattsVoltage : 115 - 230 Volts ± 10%, 50 / 60 Hz.

On horizontal flat, rigid and vibration free surface

Temperature : From + 18º C to 35º C Relative Humidity : up to 80 %

Temperature : From - 10º C to 35º C Relative Humidity : up to 80 %

ABS Fire Retardant

36 X 36 X 22 (lxwxh)

10 Kgs

Page 9: GB_DM_Single Page

Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer

GB HBV RealQuant™ PCR KitIn-Vitro Quantification of Hepatitis B Virus DNA

GB HBV RealQuant™ PCR is an in vitro real time polymerase chain

reaction (PCR) kit for the quantitation of Hepatitis B Virus (HBV) DNA

in human plasma or serum from HBV-infected individuals.

FEATURES

PERFORMANCE COMPARISON

Correlation

GB HBV RealQuant™ PCR kit shows

great result comparing with its compara-

tor. Both GB HBV RealQuant™ PCR Kit

and its comparator show equivalency

(between 37~107 IU/mL).

Accuracy

Base on Clinical and Laboratory Standards

Institute (CLSI) documents, the CV should

be less than 35%, and both Comparator

HBV Test and GB HBV RealQuant™ PCR

were passed. Both Comparator HBV Test

and GB HBV RealQuant™ PCR were shown

to be linear in serum across the range of

WHO HBV DNA concentrations.

Correlation

GB

C

Comparator log IU/mL

log IU/mL

R2=0.966

00

2

4

6

8

2 4 6 8 10

Targ

et W

HO

Con

c.

Target HBV Conc.

R2=0.955

R2=0.955

00

1

2

4

5

3

6

1 2 3 54 6log IU/mL

log IU/mL

ComparatorGB

Accuracy

SampleID

Comparator

CT value & Conc.

GB HBV RealQuant™ PCR

CT value & Conc.

L1 N/A (>1.1x108 IU/mL)

N/A (>1.1x108 IU/mL)

7.58/3.80x107 IU/mL

9.52/3.31x109 IU/mL

8.54/3.47x108 IU/mL

7.63/4.27x107 IU/mL

L2

L3

Page 10: GB_DM_Single Page

www.gbc.com.tw

+886 3 577 9221T

[email protected] E

No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C.A

+886 3 577 9227F

2013.Mar.

Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer

ORDERING INFORMATIONCatalog No. 4HBPA2S00340S00341S00352S00343S00353

Description GB HBV RealQuant™ PCR KitGB Genesis™ e1000GB Genesis™ s1000GB Genesis™ s2000QIAGEN Rotor-Gene Q - 2 channelsQIAGEN Rotor-Gene Q - 5 channels

Package 48 tests/kit1 unit1 unit1 unit1 unit1 unit

GB GenesisTM e1000 DNA/RNA Extraction System

GB GenesisTM s1000 DNA/RNA Extraction System

GB GenesisTM s2000 DNA/RNA Extraction System

QIAGEN Rotor-Gene Q - 2 channels RealTime PCR Cycler

QIAGEN Rotor-Gene Q - 5 channels RealTime PCR Cycler

GB ANALYZER ECOSYSTEM

GB HBV REALQUANT™ PCR SPECIFICATION

Certificates TFDA / CE

Linear Range 10 IU~2.0E+09 IU/mL for 0.5mL input

LOD 9.8 IU/mL for 0.5mL input, 53 IU/mL for 0.2 mL input

Precision (CV%) 2.00 (log10IU/mL)=13.87%: 4.30 (log10IU/mL)=3.12%; 6.30 (log10IU/mL)=1.41%

Genotype Detection A, B, C, D, E, F, G, wild types and mutants

Specimen Type Serum and plasma

Time to Result All processes including extraction within 3~4 hours (Manual or Automation)

Configuration Master Mix, Primer, Probe, Internal Control, 5 Quantification Standard

Standardization WHO International Standard for HBV DNA(97/746)

Page 11: GB_DM_Single Page

Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer

GB HBsAg ELISA Kit (SURASE B-96)Detecting Hepatitis B Surface Antigen

Certificates: CE marked and TFDA

Fulfilled new CTS of the European IVD Directive (2009 / 108 / EC)

Detecting all Pre Core Mutant Panel

A Hepatitis B Pre Core Mutant Panel from Teragenix, USA was

used to test and validate. Studies showed GB HBsAg (SURASE-

96) can detect the results while panel's dilution ratio is 1:2 or 1:5.

FEATURES

113A114

P120L

R122IR122TE122I

T123N122R

A12

3

C124

RT131I

T131P

Y134S

C137W

C139Y

K141E

P142L/G145R

P142L D14

4G

G14

5KC14

7T/C

148T

E164D

S174N

SURASE B-96

Reference kit

17 / 21

14 / 21

GB HBsAg ELISA Kit (SURASE B-96)

Higher Sensitivity in Mutant Sample Detection

Higher Sensitivity in Mutant Sample Detection

Page 12: GB_DM_Single Page

Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer

GB KiwiTM e2000 ELISA Automatic System

GB KiwiTM e4000 ELISA Automatic System

GB KiwiTM eGility ELISA Automatic System

GB ANALYZER ECOSYSTEM

GB HBsAg SURASE B-96 SPECIFICATION

Diagnostic Sensitivity 100% (European Performance Evaluation)

Diagnostic Specificity 99.58% (European Performance Evaluation)

Intra-assay reproducibilty The calculated CV's range between 3.7% and 11.36%

Time Saving Without sample dilution & short substrate incubation time

Substrate TMB

Certification TFDA/CE

Method direct sandwich method

Sample Type serum / plasma

Sample Volume 100 µL

Shelf Life 18 months

ORDERING INFORMATIONCatalog No. 4SGE34SGE11S00337S00338S00339

Description GB HBsAg (SURASE B-96)GB HBsAg (SURASE B-480)GB KiwiTM e2000 ELISA Automatic SystemGB KiwiTM e4000 ELISA Automatic SystemGB KiwiTM eGility ELISA Automatic System

Package 96 tests/kit480 tests/kit1 unit1 unit1 unit

www.gbc.com.tw

+886 3 577 9221T

[email protected] E

No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C.A

+886 3 577 9227F

2013.Mar.

Page 13: GB_DM_Single Page

Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer

GBTronicAutomatic Electronic Pipette

Consistent accuracy and precision can be easily achieved

User’s operation interface is as easy and graphical as your cellular phone

Light-weight and ergonomic design prevent Repetitive Stress Injury (RSI)

Multiple protocols make your tedious lab job a breeze

9 memory settings for storing your protocols

Lithium battery guarantees no leakage and more hours of operation

5 speed settings for different viscous samples

Affordable prices

Complies with ISO-8655, CE and GLP

PRODUCT HIGHLIGHTS

FOCUSING ON YOUR NEEDS

The GBTronic is one of the easiest electronic pipettes to

set and use. You can choose between the most widely

used pipetting modes including reverse pipetting, multi

dispensing, mixing and squential dispensing, or store

up to 9 of your own protocols.

Page 14: GB_DM_Single Page

Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer

ORDERING INFORMATION

S00382S00383S00384S00385

Description Inaccuracy % / Imprecision % / Color 1-channel A-pette electronic pipette, 0.5-10 ul 4-1 2.5-0.4 1-channel A-pette electronic pipette, 2-20 ul 4-1 2.5-0.4 1-channel A-pette electronic pipette, 10-200 ul 2.5-0.6 1-0.15 1-channel A-pette electronic pipette, 100-1,000 ul 2.5-0.6 0.6-0.15

www.gbc.com.tw

+886 3 577 9221T

[email protected] E

No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C.A

+886 3 577 9227F

2013.Mar.

Single

Catalog No. S00386S00387S00388S00389

Description Inaccuracy % / Imprecision % / Color 8-channel A-pette electronic pipette, 0.5-10 ul 4-1.5 2.5-0.58-channel A-pette electronic pipette, 2-20 ul 4-1 2.5-0.58-channel A-pette electronic pipette, 10-200 ul 3-0.6 1-0.158-channel A-pette electronic pipette, 100-1,200 ul 3-0.5 0.8-0.2

Multi

Catalog No.

Page 15: GB_DM_Single Page

Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer

GB Fit X1TM

Automatic Pipetting System

FOCUSING ON YOUR NEEDS

GB Fit X1TM is an automated, high-precision pipetting

system specifically designed for low-volume

PCR/qPCR sample preparation.

Fit X1TM is designed to replace the manual process of

PCR/qPCR sample preparation. Precision and consist-

ency are the key feature to make sure reagents are

dispensed accurately. Fit X1TM offers simplicity and

functionality for you to produce the best results!

Page 16: GB_DM_Single Page

www.gbc.com.tw

+886 3 577 9221T

[email protected] E

No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C.A

+886 3 577 9227F

2013.Mar.

Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer

ORDERING INFORMATIONCatalog No.Fit X1TM S00390

Interchangeable Automated Pipetting ModuleS00391S00392S00393S00394

Robotic TipsS00395S00396S00397S00398

AccessoriesS00399S00400S00401S00402S00403S00404S00405S00406S00407

Description

4-plate Automated Pipetting System with 1 x APM, 1 x PC and SoFitTM software.

1-channel, 50 ul Pipetting Module8-channel, 50 ul Pipetting Module1-channel, 200 ul Pipetting Module8-channel, 200 ul Pipetting Module

FitTipTM 50 ul, non-sterile, 96 tips/rack; 10 racks/packFitTipTM 200 ul, non-sterile, 96 tips/rack; 10 racks/packFitTipTM 50 ul, sterile, 96 tips/rack; 10 racks/packFitTipTM 200 ul, sterile, 96 tips/rack; 10 racks/pack

96 tips rack adapterLeviated 96-well PCR plate adapterLeviated 384-well PCR plate adapter4 x 2 1.5ml tubes adapter3 x 2 2ml storage tubes & 1 x 5 bottle adapterFitTipTM 96 adapter for 96-well PCR platesFitTipTM 384 adapter for 384-well PCR platesFitTipTM R10 adapter for 4 x 2 1.5ml tubesFitTipTM R20 adapter for 3 x 2 2ml storage tubes and 1 x 5ml bottle

GB FIT X1TM TECHNICAL SPECIFICATION

Worktable Capacity

2 or 3 x 96 / 384 SBS PCR plates2 or 1 x 96 tip rack (50/200 ul)Reagent Area 1: 8 x 1.5/2 ml microcentrifuge tubeReagent Area 2: 6 x 2 ml storage tube (free standing) and 1 x 5 ml bottle

Function

Liquid (Sample/Reagent) Transfer (LT)Multiple Dispense (MD)Serial Dilution (SD)Hold (Pause)Mixing (MIX)Loop

Automated Pipetting Module

Connection RS-232, USB 1.0

Power Supply 100~240V, 50/60 Hz, 100W

Size (W x D x H) 590 x 440 x 460 mm

Weight 25 Kg

Interchageable 1/8-channel, Maximum volume 50 ul/200 ul

Page 17: GB_DM_Single Page

CE Marked Reference Kit

GB anti-HCV V4.0 (NANBASE C-96 V4.0)

Ant

i-HC

Vlg

G(S

/Co)

Serial Dilution Steps0

0

5

10

15

20

25

30

5 10 15 20

GB anti-HCV V4.0 ELISA Kit (NANBASE C-96 V4.0)EIA Kit for Direct Detection of HCV Antibody

Certificates: CE marked and TFDA

New Method: double antigen direct sandwich principle

Time Saving: without sample dilution and short substrate

incubation time

FEATURES

Cut offPEI Reference MaterialHigh Positive Sample 1High Positive Sample 2Cut off

4~7 Days Earlier Detection

10X More Sensitive

Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer

GB anti-HCV V4.0 (NANBASE C-96 V4.0)

HCV Reagent Kit - Brand A

HCV Reagent Kit - Brand B

HCV Reagent Kit - Brand C

HCV Reagent Kit - Brand D

HCV Reagent Kit - Brand E

HCV Reagent Kit - Brand F

21.6 days

22.8 days

22.9 days

23.5 days

24.9 days

days

23.0 days

17.7 days

0 4 8 12 16 20 24

Page 18: GB_DM_Single Page

Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer

ORDERING INFORMATIONCatalog No. 4NAE34NAE12S00337S00338S00339

Description GB anti-HCV V4.0 (NANBASE C-96 V4.0)GB anti-HCV V4.0 (NANBASE C-480 V4.0)GB KiwiTM e2000 ELISA Automatic SystemGB KiwiTM e4000 ELISA Automatic SystemGB KiwiTM eGility ELISA Automatic System

Package 96 tests/kit480 tests/kit1 unit1 unit1 unit

GB KiwiTM e2000 ELISA Automatic System

GB KiwiTM e4000 ELISA Automatic System

GB KiwiTM eGility ELISA Automatic System

GB ANALYZER ECOSYSTEM

GB anti-HCV V4.0 (NANBASE C-96 V4.0) SPECIFICATION

www.gbc.com.tw

+886 3 577 9221T

[email protected] E

No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C.A

+886 3 577 9227F

2013.Mar.

Diagnostic Sensitivity 100.00%

Diagnostic Specificity 99.80%

Intra-assay reproducibilty The calculated CV's range between 4.7% and 8.51%

Time Saving Without sample dilution & short substrate incubation time

Substrate TMB

Certification TFDA/CE

New Method double antigen direct sandwich principle