Upload
gbc-general-biologicals-corp
View
218
Download
5
Tags:
Embed Size (px)
DESCRIPTION
Â
Citation preview
No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C.A
+886 3 577 9221T +886 3 577 9227F
AUROCFIBROSIS STAGES
BioFibroScore® >0.95 >0.95 >0.95 >0.95
F≥1 F≥2 F≥3 F≥4
Blood sampling methodLess expensive and no painful proceduresPatent pending with 3 biomarkers and an algorithm to generate results in 4 different stagesValidated with 500+ samples
Hepatitis BHepatitis CAlcoholic Liver DiseaseMetabolic / Non-Alcoholic Fatty Liver Disease
BioFibroScore® platform shows an excellent accuracy (>0.95) in all stages, especially in early stages.The technology has been offered as a service bundling as Liver20TM.
®
ELISA Kits & Instruments, RT-PCR & instruments, Raw Materials, Labware, & CLIA (new)
Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer
GB WatoTM
An Automatic ELISA Plate Washer
Specifically designed Manifold assembly to prevent any scratching on bottom of well
Programmable soak time, wash cycles and dispensing volume
Onboard two-plate incubator at 37�with programmable timer
Waste bottle full warning with audible alarm
Built-in stabilizer
Continuous aspiration to prevent overflow
Removable manifold
Ability to wash single strip of 8 wells
PRODUCT HIGHLIGHTS
FOCUSING ON YOUR NEEDS
Various types of plate can be supported and are easily
inter-changeable in the plate carrier to maximize the
washing performance. GB WatoTM is an automatic
ELISA Strip / Plate Washer with built-in incubator &
programmable timer.
Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer
ORDERING INFORMATIONCatalog No. S00346
Description GB WatoTM
Package 1 unit
GB WATOTM TECHNICAL SPECIFICATION
Manifold 8 Way Manifold Dispensing
Dispensing Method : Specially designed Peristaltic PumpVolume : 300 to 400 µL in steps of 50 µL
AspiratingMethod : Continuous through diaphragm pump while Dispensing hence preventing overflowResidual Volume : < 5 µL
Waste Bottle One (Capacity 2 liters) with audible alarm when bottle is completely filled in with waste solution
Wash Bottle One (Capacity 2 liters)
Rinse Bottle One (Capacity 2 liters)
Display Single line Backlit LCD with 16 characters
Liquid contact materials Silicon, Stainless steel, derline
Memory 8 KB Non volatile RAM battery back up suppor ting 35 open channels
Washing Method Longwash, Shortwash Rinsing, Priming
Incubator For Two ELISA Plates, 37º C
Timer
Power
Operating Position
Operating Conditions
Storage Conditions
Enclosure
Size (cm)
Weight
Individually Programmable
Wattage : 50 WattsVoltage : 115 - 230 Volts ± 10%, 50 /60 Hz.
On horizontal, rigid, flat and vibration free surface
Temperature : + 18º C to 35º C Humidity : up to 85 %
Temperature : - 10º C to 60º C Humidity : up to 85 %
ABS Fire retardant
35 X 35 X 13 (lxwxh)
6 Kgs
www.gbc.com.tw
+886 3 577 9221T
No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C.A
+886 3 577 9227F
2013.Mar.
Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer
GB TempCardTM
Temperature Recorder
Alert indicator – indicates if readings are outside of preset limits
OK indicator indicates if still recording and if readings within configured limits
Credit card sized case – thin enough to be easily mailed “letter rate”.
Real time clock records time & temperature simultaneously
Highly reliable and accurate
Pre-Start Logging - Configurable to record even when "start" button has not been pressed
High performance at lower cost
Credit Card sized design - easy to carry and transport
Re-calibration function available
PRODUCT HIGHLIGHTS
MADE SPECIALLY FOR YOU
GB TempCardTM Temperature Recorder incorporates an innovative
temperature sensor built inside this portable device. GB TempCardTM
has been designed to endure hard damages yet still provide a fast
reaction time.
USER-FRIENDLY INTERFACE
GB TempCardTM comes with a great user-friendly interface software, TempCardTM Analyzer, for
reading and analyzing collected data. GB TempCardTM Analyzer provides functions including
delayed start, sampling interval, number of readings, continuous or fixed number of readings
and ALERT function setup.
Data recorded can be downloaded or exported in excel.
www.gbc.com.tw
+886 3 577 9221T
No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C.A
+886 3 577 9227F
2013/Mar.
Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer
ORDERING INFORMATIONCatalog No. S00351
Description GB TempCardTM
Package 1 unit
GB TEMPCARDTM TECHNICAL SPECIFICATION
Capacity 8000 temperature readings (16Kbytes memory)
Frequency Adjustable, 30 seconds to several hours
Download TimeTypically with full memory in less than 5 seconds depending on computer or readout device used
Environmental IP65
Battery 3V Lithium
Life 2~3 years on regular uses
Real Time Clock
Installed with Real Time Clock.Rated accuracy ±25ppm @ 25°C (equiv to 2.5 seconds/day) Rated temperature coefficient is -0.034±0.006ppm/°C (i.e typically +/- 0.00294seconds/day/°C)
Dimension 86mm (L) x 55mm (W) x 8.6mm (H)
Weight 35g
Case Material Polycarbonate
EMC Compliance Tested and complies with EC EMC directives (EN 50081-1:1992 & EN 61000-6-1:2001)
EN12380 Compliance Tested and complies to EN12830:1999 for transport, storage and distribution of chilled, frozen, deep frozen, quick-frozen food and others
Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer
GB RitoTM
An Automatic ELISA Plate Reader
Built-in shaker with variable speed & duration
Results printing in matrix mode format
Option to run multiple blank in cut-off mode
Bichromatic readings
Ability to read from any strip in a single plate
Extensive curve plotting
Robust system with built-in stabilizer
PRODUCT HIGHLIGHTS
FOCUSING ON YOUR NEEDS
GB RitoTM is an automatic ELISA Plate Reader with
user-friendly touch interface and software. GB RitoTM
can be used for all routine immunoassays, biochemi-
cals, hormones, and drug levels. It is an economical
reliable and high precision instrument.
www.gbc.com.tw
+886 3 577 9221T
No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C.A
+886 3 577 9227F
2013.Mar.
Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer
ORDERING INFORMATIONCatalog No. S00345
Description GB RitoTM
Package 1 unit
GB RITOTM TECHNICAL SPECIFICATION
Interface TOUCH PANEL / KEYPAD
Linear measurement range 0.000 to 3.000 Absorbance Units(A)
Photometirc Accuracy ± 2% or 0.005 whichever is higher, from 0 to 1.5 A± 3% from 1.5 A to 3.0 A
Drift <0.005 A/hr
Photometric Linearity 2.5 A
Optical measurement 8 Channel
Filters
Type of Filter : Narrow band InterferenceWave Length : 405nm, 450nm, 492nm, 560nm, 630nmHalf Bandwidth : 10 nm ± 2nmSelection : Automatic by Stepper Motor
Light Source Tungsten halogen lamp
Warm up time 90 seconds (built - in)
Display 6” Graphics LCD, Negative Blue, STN
Curve Plotting Graphical Representation on Printer
Plate Carrier Movement
Printer
Memory
Analysis Mode
RS232 Serial Port
Power
Operating Position
Operating Conditions
Storage Conditions
Enclosure
Size (cm)
Weight
Precisely through the stepper motor
Built in Thermal Printer 52 columns
64 KB Non Volatile RAM Battery backupsuppor ting125 open channels
Absorbance Cut - offMulti - Standard % Absorbance
2400 baud, 8 data, 1 stop, no parity bits / USB
Wattage : 50 WattsVoltage : 115 - 230 Volts ± 10%, 50 / 60 Hz.
On horizontal flat, rigid and vibration free surface
Temperature : From + 18º C to 35º C Relative Humidity : up to 80 %
Temperature : From - 10º C to 35º C Relative Humidity : up to 80 %
ABS Fire Retardant
36 X 36 X 22 (lxwxh)
10 Kgs
Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer
GB HBV RealQuant™ PCR KitIn-Vitro Quantification of Hepatitis B Virus DNA
GB HBV RealQuant™ PCR is an in vitro real time polymerase chain
reaction (PCR) kit for the quantitation of Hepatitis B Virus (HBV) DNA
in human plasma or serum from HBV-infected individuals.
FEATURES
PERFORMANCE COMPARISON
Correlation
GB HBV RealQuant™ PCR kit shows
great result comparing with its compara-
tor. Both GB HBV RealQuant™ PCR Kit
and its comparator show equivalency
(between 37~107 IU/mL).
Accuracy
Base on Clinical and Laboratory Standards
Institute (CLSI) documents, the CV should
be less than 35%, and both Comparator
HBV Test and GB HBV RealQuant™ PCR
were passed. Both Comparator HBV Test
and GB HBV RealQuant™ PCR were shown
to be linear in serum across the range of
WHO HBV DNA concentrations.
Correlation
GB
C
Comparator log IU/mL
log IU/mL
R2=0.966
00
2
4
6
8
2 4 6 8 10
Targ
et W
HO
Con
c.
Target HBV Conc.
R2=0.955
R2=0.955
00
1
2
4
5
3
6
1 2 3 54 6log IU/mL
log IU/mL
ComparatorGB
Accuracy
SampleID
Comparator
CT value & Conc.
GB HBV RealQuant™ PCR
CT value & Conc.
L1 N/A (>1.1x108 IU/mL)
N/A (>1.1x108 IU/mL)
7.58/3.80x107 IU/mL
9.52/3.31x109 IU/mL
8.54/3.47x108 IU/mL
7.63/4.27x107 IU/mL
L2
L3
www.gbc.com.tw
+886 3 577 9221T
No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C.A
+886 3 577 9227F
2013.Mar.
Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer
ORDERING INFORMATIONCatalog No. 4HBPA2S00340S00341S00352S00343S00353
Description GB HBV RealQuant™ PCR KitGB Genesis™ e1000GB Genesis™ s1000GB Genesis™ s2000QIAGEN Rotor-Gene Q - 2 channelsQIAGEN Rotor-Gene Q - 5 channels
Package 48 tests/kit1 unit1 unit1 unit1 unit1 unit
GB GenesisTM e1000 DNA/RNA Extraction System
GB GenesisTM s1000 DNA/RNA Extraction System
GB GenesisTM s2000 DNA/RNA Extraction System
QIAGEN Rotor-Gene Q - 2 channels RealTime PCR Cycler
QIAGEN Rotor-Gene Q - 5 channels RealTime PCR Cycler
GB ANALYZER ECOSYSTEM
GB HBV REALQUANT™ PCR SPECIFICATION
Certificates TFDA / CE
Linear Range 10 IU~2.0E+09 IU/mL for 0.5mL input
LOD 9.8 IU/mL for 0.5mL input, 53 IU/mL for 0.2 mL input
Precision (CV%) 2.00 (log10IU/mL)=13.87%: 4.30 (log10IU/mL)=3.12%; 6.30 (log10IU/mL)=1.41%
Genotype Detection A, B, C, D, E, F, G, wild types and mutants
Specimen Type Serum and plasma
Time to Result All processes including extraction within 3~4 hours (Manual or Automation)
Configuration Master Mix, Primer, Probe, Internal Control, 5 Quantification Standard
Standardization WHO International Standard for HBV DNA(97/746)
Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer
GB HBsAg ELISA Kit (SURASE B-96)Detecting Hepatitis B Surface Antigen
Certificates: CE marked and TFDA
Fulfilled new CTS of the European IVD Directive (2009 / 108 / EC)
Detecting all Pre Core Mutant Panel
A Hepatitis B Pre Core Mutant Panel from Teragenix, USA was
used to test and validate. Studies showed GB HBsAg (SURASE-
96) can detect the results while panel's dilution ratio is 1:2 or 1:5.
FEATURES
113A114
P120L
R122IR122TE122I
T123N122R
A12
3
C124
RT131I
T131P
Y134S
C137W
C139Y
K141E
P142L/G145R
P142L D14
4G
G14
5KC14
7T/C
148T
E164D
S174N
SURASE B-96
Reference kit
17 / 21
14 / 21
GB HBsAg ELISA Kit (SURASE B-96)
Higher Sensitivity in Mutant Sample Detection
Higher Sensitivity in Mutant Sample Detection
Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer
GB KiwiTM e2000 ELISA Automatic System
GB KiwiTM e4000 ELISA Automatic System
GB KiwiTM eGility ELISA Automatic System
GB ANALYZER ECOSYSTEM
GB HBsAg SURASE B-96 SPECIFICATION
Diagnostic Sensitivity 100% (European Performance Evaluation)
Diagnostic Specificity 99.58% (European Performance Evaluation)
Intra-assay reproducibilty The calculated CV's range between 3.7% and 11.36%
Time Saving Without sample dilution & short substrate incubation time
Substrate TMB
Certification TFDA/CE
Method direct sandwich method
Sample Type serum / plasma
Sample Volume 100 µL
Shelf Life 18 months
ORDERING INFORMATIONCatalog No. 4SGE34SGE11S00337S00338S00339
Description GB HBsAg (SURASE B-96)GB HBsAg (SURASE B-480)GB KiwiTM e2000 ELISA Automatic SystemGB KiwiTM e4000 ELISA Automatic SystemGB KiwiTM eGility ELISA Automatic System
Package 96 tests/kit480 tests/kit1 unit1 unit1 unit
www.gbc.com.tw
+886 3 577 9221T
No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C.A
+886 3 577 9227F
2013.Mar.
Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer
GBTronicAutomatic Electronic Pipette
Consistent accuracy and precision can be easily achieved
User’s operation interface is as easy and graphical as your cellular phone
Light-weight and ergonomic design prevent Repetitive Stress Injury (RSI)
Multiple protocols make your tedious lab job a breeze
9 memory settings for storing your protocols
Lithium battery guarantees no leakage and more hours of operation
5 speed settings for different viscous samples
Affordable prices
Complies with ISO-8655, CE and GLP
PRODUCT HIGHLIGHTS
FOCUSING ON YOUR NEEDS
The GBTronic is one of the easiest electronic pipettes to
set and use. You can choose between the most widely
used pipetting modes including reverse pipetting, multi
dispensing, mixing and squential dispensing, or store
up to 9 of your own protocols.
Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer
ORDERING INFORMATION
S00382S00383S00384S00385
Description Inaccuracy % / Imprecision % / Color 1-channel A-pette electronic pipette, 0.5-10 ul 4-1 2.5-0.4 1-channel A-pette electronic pipette, 2-20 ul 4-1 2.5-0.4 1-channel A-pette electronic pipette, 10-200 ul 2.5-0.6 1-0.15 1-channel A-pette electronic pipette, 100-1,000 ul 2.5-0.6 0.6-0.15
www.gbc.com.tw
+886 3 577 9221T
No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C.A
+886 3 577 9227F
2013.Mar.
Single
Catalog No. S00386S00387S00388S00389
Description Inaccuracy % / Imprecision % / Color 8-channel A-pette electronic pipette, 0.5-10 ul 4-1.5 2.5-0.58-channel A-pette electronic pipette, 2-20 ul 4-1 2.5-0.58-channel A-pette electronic pipette, 10-200 ul 3-0.6 1-0.158-channel A-pette electronic pipette, 100-1,200 ul 3-0.5 0.8-0.2
Multi
Catalog No.
Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer
GB Fit X1TM
Automatic Pipetting System
FOCUSING ON YOUR NEEDS
GB Fit X1TM is an automated, high-precision pipetting
system specifically designed for low-volume
PCR/qPCR sample preparation.
Fit X1TM is designed to replace the manual process of
PCR/qPCR sample preparation. Precision and consist-
ency are the key feature to make sure reagents are
dispensed accurately. Fit X1TM offers simplicity and
functionality for you to produce the best results!
www.gbc.com.tw
+886 3 577 9221T
No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C.A
+886 3 577 9227F
2013.Mar.
Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer
ORDERING INFORMATIONCatalog No.Fit X1TM S00390
Interchangeable Automated Pipetting ModuleS00391S00392S00393S00394
Robotic TipsS00395S00396S00397S00398
AccessoriesS00399S00400S00401S00402S00403S00404S00405S00406S00407
Description
4-plate Automated Pipetting System with 1 x APM, 1 x PC and SoFitTM software.
1-channel, 50 ul Pipetting Module8-channel, 50 ul Pipetting Module1-channel, 200 ul Pipetting Module8-channel, 200 ul Pipetting Module
FitTipTM 50 ul, non-sterile, 96 tips/rack; 10 racks/packFitTipTM 200 ul, non-sterile, 96 tips/rack; 10 racks/packFitTipTM 50 ul, sterile, 96 tips/rack; 10 racks/packFitTipTM 200 ul, sterile, 96 tips/rack; 10 racks/pack
96 tips rack adapterLeviated 96-well PCR plate adapterLeviated 384-well PCR plate adapter4 x 2 1.5ml tubes adapter3 x 2 2ml storage tubes & 1 x 5 bottle adapterFitTipTM 96 adapter for 96-well PCR platesFitTipTM 384 adapter for 384-well PCR platesFitTipTM R10 adapter for 4 x 2 1.5ml tubesFitTipTM R20 adapter for 3 x 2 2ml storage tubes and 1 x 5ml bottle
GB FIT X1TM TECHNICAL SPECIFICATION
Worktable Capacity
2 or 3 x 96 / 384 SBS PCR plates2 or 1 x 96 tip rack (50/200 ul)Reagent Area 1: 8 x 1.5/2 ml microcentrifuge tubeReagent Area 2: 6 x 2 ml storage tube (free standing) and 1 x 5 ml bottle
Function
Liquid (Sample/Reagent) Transfer (LT)Multiple Dispense (MD)Serial Dilution (SD)Hold (Pause)Mixing (MIX)Loop
Automated Pipetting Module
Connection RS-232, USB 1.0
Power Supply 100~240V, 50/60 Hz, 100W
Size (W x D x H) 590 x 440 x 460 mm
Weight 25 Kg
Interchageable 1/8-channel, Maximum volume 50 ul/200 ul
CE Marked Reference Kit
GB anti-HCV V4.0 (NANBASE C-96 V4.0)
Ant
i-HC
Vlg
G(S
/Co)
Serial Dilution Steps0
0
5
10
15
20
25
30
5 10 15 20
GB anti-HCV V4.0 ELISA Kit (NANBASE C-96 V4.0)EIA Kit for Direct Detection of HCV Antibody
Certificates: CE marked and TFDA
New Method: double antigen direct sandwich principle
Time Saving: without sample dilution and short substrate
incubation time
FEATURES
Cut offPEI Reference MaterialHigh Positive Sample 1High Positive Sample 2Cut off
4~7 Days Earlier Detection
10X More Sensitive
Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer
GB anti-HCV V4.0 (NANBASE C-96 V4.0)
HCV Reagent Kit - Brand A
HCV Reagent Kit - Brand B
HCV Reagent Kit - Brand C
HCV Reagent Kit - Brand D
HCV Reagent Kit - Brand E
HCV Reagent Kit - Brand F
21.6 days
22.8 days
22.9 days
23.5 days
24.9 days
days
23.0 days
17.7 days
0 4 8 12 16 20 24
Your Liver. We Care.Industry-Leading In-Vitro Diagnostic Device Manufactuer
ORDERING INFORMATIONCatalog No. 4NAE34NAE12S00337S00338S00339
Description GB anti-HCV V4.0 (NANBASE C-96 V4.0)GB anti-HCV V4.0 (NANBASE C-480 V4.0)GB KiwiTM e2000 ELISA Automatic SystemGB KiwiTM e4000 ELISA Automatic SystemGB KiwiTM eGility ELISA Automatic System
Package 96 tests/kit480 tests/kit1 unit1 unit1 unit
GB KiwiTM e2000 ELISA Automatic System
GB KiwiTM e4000 ELISA Automatic System
GB KiwiTM eGility ELISA Automatic System
GB ANALYZER ECOSYSTEM
GB anti-HCV V4.0 (NANBASE C-96 V4.0) SPECIFICATION
www.gbc.com.tw
+886 3 577 9221T
No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C.A
+886 3 577 9227F
2013.Mar.
Diagnostic Sensitivity 100.00%
Diagnostic Specificity 99.80%
Intra-assay reproducibilty The calculated CV's range between 4.7% and 8.51%
Time Saving Without sample dilution & short substrate incubation time
Substrate TMB
Certification TFDA/CE
New Method double antigen direct sandwich principle
Sample Type serum / plasma
Sample Volume 100 µL
Shelf Life 18 months