18
Gas solid flow in a CFB with L-valve and impact of gas distribution changes in the design Arenales, J., Perez, V. and Murillo, J.M. 26 September 2014 1 69 th IEA-FBC meeting Jorge Arenales Rivera CEDER-CIEMAT Autovia A-15, Salida 56, 42290, Lubia (SORIA) e-mail: [email protected] Tlf:975-281013

Gas solid flow in a CFB with L-valve and impact of gas distribution changes … · 2017-02-21 · Gas solid flow in a CFB with L-valve and impact of gas distribution changes in the

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Gas solid flow in a CFB with L-valve and impact of gas distribution changes … · 2017-02-21 · Gas solid flow in a CFB with L-valve and impact of gas distribution changes in the

Gas solid flow in a CFB with L-valve and impact of gas distributionchanges in the design

Arenales, J., Perez, V. and Murillo, J.M.

26 September 2014 169th IEA-FBC meeting

Jorge Arenales Rivera

CEDER-CIEMAT

Autovia A-15, Salida 56, 42290, Lubia (SORIA)

e-mail: [email protected]

Tlf:975-281013

Page 2: Gas solid flow in a CFB with L-valve and impact of gas distribution changes … · 2017-02-21 · Gas solid flow in a CFB with L-valve and impact of gas distribution changes in the

Circulating fluidized bed gasifier

• Main design parameters

– Size

• Driser: 300 mm; Hriser: 8800 mm

– Maximum operation pressure: 0.2 bar

– Maximum temperature: 950 ºC

– Gas velocity: 3-6 m/s

– Maximum air gasification flow rate: 300 Nm3/h

– Fuel rate: 100 kg/h

26 September 2014 69th IEA-FBC meeting 2

Page 3: Gas solid flow in a CFB with L-valve and impact of gas distribution changes … · 2017-02-21 · Gas solid flow in a CFB with L-valve and impact of gas distribution changes in the

Circulating fluidized bed gasifier

21 September 2014 69th IEA-FBC meeting 3

Page 4: Gas solid flow in a CFB with L-valve and impact of gas distribution changes … · 2017-02-21 · Gas solid flow in a CFB with L-valve and impact of gas distribution changes in the

Circulating fluidized bed gasifier

• Gas/solids flow performance

– Selection of bed material

– Exit type

• Abrupt exit

– Solids flow control (aireation)

• U-type loop-seal

– Recycle chamber

– Supply chamber

– Horizontal passage

26 September 2014 69th IEA-FBC meeting 4

Page 5: Gas solid flow in a CFB with L-valve and impact of gas distribution changes … · 2017-02-21 · Gas solid flow in a CFB with L-valve and impact of gas distribution changes in the

Bed material

• Bed material

– Silica sand

204 μm/428 μm

ρp ~2500 kg/m3

ρbulk ~1520 kg/m3

26 September 2014 69th IEA-FBC meeting 5

Geldart, D. Powder Technology, 1, 285, 1973

Page 6: Gas solid flow in a CFB with L-valve and impact of gas distribution changes … · 2017-02-21 · Gas solid flow in a CFB with L-valve and impact of gas distribution changes in the

Bed material

• Granulometry – Conventional method

• Sand 204 μm

• Sand 428 μm

26 September 2014 69th IEA-FBC meeting 6

pii

pdx

d/

1

0,00

10,00

20,00

30,00

40,00

50,00

60,00

70,00

80,00

90,00

100,00

0 1 2 3 4

Volu

me (%

)

Particle diameter (mm)

204

428

Page 7: Gas solid flow in a CFB with L-valve and impact of gas distribution changes … · 2017-02-21 · Gas solid flow in a CFB with L-valve and impact of gas distribution changes in the

CFB Cold flow model

26 September 2014 69th IEA-FBC meeting 7

Page 8: Gas solid flow in a CFB with L-valve and impact of gas distribution changes … · 2017-02-21 · Gas solid flow in a CFB with L-valve and impact of gas distribution changes in the

CFB Cold flow model

• Main design parameters

– Plexiglas model

• Driser: 192 mm; Hriser: 4550 mm

• Dstandpipe: 92 mm; Hstandpipe: 2700 mm

• DL-valve: 92 mm; Lhorizontal passage: 480 mm

– Maximum operation pressure: 0.2 bar

– Gas velocity: 3-6 m/s

– Maximum air gasification flow rate: 600 Nm3/h

26 September 2014 69th IEA-FBC meeting 8

Page 9: Gas solid flow in a CFB with L-valve and impact of gas distribution changes … · 2017-02-21 · Gas solid flow in a CFB with L-valve and impact of gas distribution changes in the

Bed material selection

• Sand a) 428 μm– Solids inventory: 25-35 kg

– Aireation flow rate: 50-70 L/min

– Superficial velocity: 5-6 m/s

• Sand b) 204 μm– Solids inventory: 25-35 kg

– Aireation flow rate: 25-46 L/min

– Superficial velocity: 3.5-5 m/s

26 September 2014 69th IEA-FBC meeting 9

Page 10: Gas solid flow in a CFB with L-valve and impact of gas distribution changes … · 2017-02-21 · Gas solid flow in a CFB with L-valve and impact of gas distribution changes in the

Solids flow measurement

• External solids flow

– Butterfly valve

– Graduate Pipe

• Internal solids flow

– Non-isokinetic probe

26 September 2014 69th IEA-FBC meeting 10

Page 11: Gas solid flow in a CFB with L-valve and impact of gas distribution changes … · 2017-02-21 · Gas solid flow in a CFB with L-valve and impact of gas distribution changes in the

Solids flow measurement

• External solids flow

– Solids mass flux (Gs)

26 September 2014 69th IEA-FBC meeting 11

Page 12: Gas solid flow in a CFB with L-valve and impact of gas distribution changes … · 2017-02-21 · Gas solid flow in a CFB with L-valve and impact of gas distribution changes in the

Solids flow measurement

• Internal solids flow

– Solids mass flux

Preliminary results (non-isokinetic probe)

26 September 2014 69th IEA-FBC meeting 12

Solids inventory

(35 kg)

Aireation flow rate

(37 L/min)

Internal solids

mass flux (kg/sm2)

External solids

mass flux (kg/sm2)

us (4 m/s) 27 6.4

us (4,5 m/s) 31.8 10.6

Page 13: Gas solid flow in a CFB with L-valve and impact of gas distribution changes … · 2017-02-21 · Gas solid flow in a CFB with L-valve and impact of gas distribution changes in the

Circulating fluidized bed gasifier

• Gas distributor design

– Riser

• Bubble-cap type

(abrasion)

– Loop-seal

• Perforated pipes

(Supply chamber)

(Recycle chamber)

26 September 2014 69th IEA-FBC meeting 13

Page 14: Gas solid flow in a CFB with L-valve and impact of gas distribution changes … · 2017-02-21 · Gas solid flow in a CFB with L-valve and impact of gas distribution changes in the

Non-mechanical valve

• Supply chamber

– Aireation tap

(L-valve design)

• Recycle chamber

– Perforated pipes

– Perforated plate

– Porous plate

26 September 2014 69th IEA-FBC meeting 14

Page 15: Gas solid flow in a CFB with L-valve and impact of gas distribution changes … · 2017-02-21 · Gas solid flow in a CFB with L-valve and impact of gas distribution changes in the

Solids flow measurement

• Perforated plate

– Staggered

distribution

– Dhole: 1 mm

– Step: 0.129 mm

26 September 2014 69th IEA-FBC meeting 15

Page 16: Gas solid flow in a CFB with L-valve and impact of gas distribution changes … · 2017-02-21 · Gas solid flow in a CFB with L-valve and impact of gas distribution changes in the

Solids flow measurement

• Porous plate

– Glass filter

– Por. 2 P100

(ISO 4793-80)

– Poresize 40-100 μm

– Diameter: 140 mm

– Tickness: 10 mm

26 September 2014 69th IEA-FBC meeting 16

Page 17: Gas solid flow in a CFB with L-valve and impact of gas distribution changes … · 2017-02-21 · Gas solid flow in a CFB with L-valve and impact of gas distribution changes in the

Future work

• Test different bed materials

• Experiments with an U-type loop-seal in a

CFB cold flow model

• Re-design of loop-seal in the circulating

fluidized bed gasifier pilot plant

26 September 2014 69th IEA-FBC meeting 17

Page 18: Gas solid flow in a CFB with L-valve and impact of gas distribution changes … · 2017-02-21 · Gas solid flow in a CFB with L-valve and impact of gas distribution changes in the

Thank you for your attention

26 September 2014 69th IEA-FBC meeting 18