FEATURES�� Double-wound helical coil design
�� Minimizes cooling water needs
�� Wide variety of exotic alloys for corrosion resistance
�� Retained shellside gasket reduces reassembly time
�� Formed shell eliminates top shell flange weld interfaces
�� Mounting bracket can be installed without removing flange bolts
�� All 316 SS construction available where higher corrosive resistance is desired
SENTRY TLR SINGLE HELICAL TUBE Sample Coolers
S A M P L E CO N D I T I O N I N G
Gas
Liquid & Slurry
Solid & Powder
Steam & Water
The Sentry® TLR sample cooler/heat exchanger cools a sample from a process stream. It may seem simple, but it is a uniquely designed small tube and shell heat exchanger. The sample to be cooled flows through the tube side of the cooler, and the cooling fluid flows through the shell side. The cooled sample then is taken to a laboratory for analysis or piped to in-line process instrumentation for continuous monitoring of properties such as conductivity, pH or other chemical constituents.
MODELS
TLR-4225 | TLR-42B5 | TLR-4525(S) | TLR-4BB5
TLR-4225U | TLR-42B5U | TLR-4525U(S) |
BENEFITSThe Sentry TLR sample cooler is the most efficient and cost-effective sample cooler available. Offers optimal service for flows below 1800 cc per minute for single phase and below 1000 cc per minute for condensing heat transfer. The Sentry TLR sample cooler is optimized for steam condensing service.
5
10
15
20
25
App
roac
h Te
mpe
ratu
re (o
C)
60
50
40
30
20
10
0
Pres
sure
Dro
p (P
SI)
1 PS
I = 0
.069
Bar
0
10
20
30
40
50
App
roac
h Te
mpe
ratu
re (o
F)
400 600 800 1000 1200 1400 1600 1800 2000CCM
0.1 0.2 0.3 0.4 0.5GPM
60 80 100 120 140 160 180 200 220 240 260 280Lbm/Hr
Model TL -4225 Surface Area 2.4 Ft.2 [0.22 m2]
5 GPM [18.9 L/min] Cooling Water at 95oF [35oC]5 PSI [0.35 Bar] Pressure Drop
Sample Pressure Drop (PSI)
Flow Rate
600o F (3
16o C)
500o F (260o C)
400o F (204o C)
300o F (149o C)
200oF (93oC)
Inlet Temp. 150oF (66oC)
700
o F (3
71o C)
R
PERFORMANCE CURVE - WATER
5
10
15
App
roac
h Te
mpe
ratu
re (o
C)
0
10
20
30
App
roac
h Te
mpe
ratu
re (o
F)
400 600 800 1000 1200CCM
0.1 0.2 0.3GPM
40 50 60 70 80 90 100 110 120 130 140 150 160 170Lbm/Hr
Model TL -4225 Surface Area 2.4 Ft.2 [0.22 m2]
7 GPM [26.5 L/min] Cooling Water at 95oF [35oC]9.5 PSI [0.66 Bar] Pressure Drop
Flow Rate
500
PSIA
[34.
5 ba
r(a)
]
1000
PSI
A [6
8.9
bar(a
)]
1500
PSI
A [103
.4 ba
r(a)]
2000
PSIA
[137
.9 ba
r(a)]
2500
PSIA [1
72.4
bar(a)]
3100 PSIA [213.7 bar(a
)]
Satu
rate
d St
eam
Inle
t Pre
ssur
e
R
PERFORMANCE CURVE - STEAM
SPECIFICATIONSmodels shell design tube design tube material shell material area shipping weight part number
TLR-4225 450 psi at 650°F (31 bar at 343°C)
5000 psi at 1000°F (345 bar at 538°C)
316/316L SS 1/4 in OD x 0.049 in AW
304 SS2.4 ft2
(0.22 m2)17 lb (8 kg) 7-03951A
TLR-4225U 450 psi at 650°F (31 bar at 343°C)
4400 psi at 1000°F (303 bar at 538°C)
316/316L SS 1/4 in OD x 0.049 in AW
304 SS2.4 ft2
(0.22 m2)17 lb (8 kg) 7-03951B
TLR-42B5 450 psi at 650°F (31 bar at 343°C)
5000 psi at 1100°F (345 bar at 593°C)
Alloy 625 1/4 in OD x 0.035 in AW
304 SS2.4 ft2
(0.22 m2)17 lb (8 kg) 7-03951C
TLR-42B5U 450 psi at 650°F (31 bar at 343°C)
5000 psi at 1100°F (345 bar at 593°C)
Alloy 625 1/4 in OD x 0.035 in AW
304 SS2.4 ft2
(0.22 m2)17 lb (8 kg) 7-03951D
TLR-4525(S) 430 psi at 650°F (30 bar at 343°C)
5000 psi at 1000°F (345 bar at 538°C)
316/316L SS 1/4 in OD
316 SS2.4 ft2
(0.22 m2)17 lb (8 kg) 7-04067D
TLR-4525U(S) 430 psi at 650°F (30 bar at 343°C)
4400 psi at 1000°F (303 bar at 538°C)
316 SS 1/4 in OD
316 SS2.4 ft2
(0.22 m2)17 lb (8 kg) 7-04067M
TLR-4BB5 450 psi at 650°F (31 bar at 343°C)
5000 psi at 1100°F (345 bar at 593°C)
Alloy 625 1/4 in OD x 0.035 in AW
Alloy 6252.4 ft2
(0.22 m2)17 lb (8 kg) 7-03951E
sentry-equip.com 966 Blue Ribbon Circle North, Oconomowoc, WI 53066 U.S.A. | +1-262-567-7256 | [email protected]
© 2016 Sentry Equipment Corp. All rights reserved. All product and company names are property of their respective owners. It is solely the responsibility of end users, through their own testing and analysis, to select products and materials suitable for their specific application requirements, ensure they are properly installed, safely applied and properly maintained, and to limit their use to their intended purpose. Improper selection, installation or use may result in personal injury or property damage.
S-SC&HE-SPS-00135-13 5-17
S E N T R Y T L R S I N G L E H E L I C A L T U B E > S A M P L E CO O L E R S > S A M P L E CO N D I T I O N I N G
4 7/8 [124 mm]
4 7/8 in. [124 mm]
11 3/16 in. [283 mm]
4 3/8 in. [111 mm]
3/4 in. [19 mm]
1/4 in. [6 mm]
13/16 in. [21 mm]1 1/4 in. [32 mm]
4 1/4 in. [108 mm]
2 1/4 in. [57 mm]
2 7/16 in. [61 mm]3 5/16 in. [84 mm]
1/8 in. [3 mm]
MOUNTING BRACKET(SUPPLIED WITH EACH COOLER)
3/4 in. FNPTcooling water inlet
1/4˝ O.D. SAMPLE INLET
1/4˝ O.D. SAMPLE OUTLET
1/2 in. FNPTcooling water outlet
NOTES:• U in model number denotes ASME stamped model.• Canadian Registration Number available for ASME stamped models only. Consult factory for CRN and other options and information.• Vessels are exempt from CE marking per PED 2014/68/EU, TÜV. Vessels are below or equal to the limits set forth in Article 4, Sections 1(a), 1(b), 1(c) and Section 2 as applicable, and are designed and manufactured
in accordance with sound engineering practice (meets the general requirements of the ASME Section VIII, Division 1, Boiler And Pressure Vessel Code). Nameplate will bear the Sentry name and safety instructions will be included per Article 4, Section 2.