Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
clinical references – références cliniques
Graham,J.D.,Green,L.C.,Roberts,M.J.,(1988)InSearchofSafety«ChemicalsandCancerRisk»HarvardUniversityPress,CambridgePress
Office of Occupational Medicine, (January 29, 1986) Guidelines for Handling CDs. OccupationalSafetyandHealthAdministrationActPublication,Pub8-11.
SpecialFeature,(May1990)ASHPTechnicalAssistanceBulletinonHandlingCytotoxicandHazardousDrugs,AmericanJournalofHospitalPharmacy,47,1033-49.
Sotaniemi,E.A.,Sutinen,S.,Arranto,A.J.etal(1983)LiverDamageinNurseshandlingcystostaticagents,ActaMedScand,214,181-9.
Oncology Nursing Society, (1999) Cancer Chemotherapy Guidelines and Recommendations forPractice,2thedition,27.
WorldHealthOrganization,Globalcancerratescouldincreaseby50%to15millionby2020,http://www.who.int/mediacentre/news/releases/2003/pr27/en/retrivedinMarch23,2009from.
Foradditionalinformationandsamples,callAnsellCanadaat1800363-8340
®&TMaretrademarksownedbyAnsellHealthcareProductsLLCoroneofitsaffiliates.©2009AllRightsReserved.
Sivousdésirezrecevoirdeséchantillonsoudeplusamplesrenseignements,appelezAnsellCanadaau800-363-8340.
® & TM sont des marques déposées de Ansell Healthcare Products LLC ou une société affiliée.©2009Tousdroitsréservés.
ansell canada105Lauder,CowansvilleQCJ2K2K8www.ansellcanada.caPrintedinCanada.©2009AllRightsReserved.ImpriméauCanada.©2009Tousdroitsréservés.
ProDucT name ProDucT coDe chemoTheraPy DruGS TeSTeD
latex Powder-Free examination GlovesMicro-Touch®E.P.®Gloves 920155/920785 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Synthetic Powder-Free examination GlovesMicro-Touch®Affinity®-Neoprene 3770/3774 ● ● ● ● ● ● ● ● ●
Micro-Touch®NitraFree™-Nitrile 6034510/6034514 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Micro-Touch®Nitra-Touch®-Nitrile 6034010/6034014 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Micro-Touch®Nitrile 4000/4008 ● ● ● ▲ ● ▲ ● ▲ ● ▲ ● ● ▲ ● ▲ ● ▲ ● ● ● ● ● ● ▲ ● ▲ ●
Micro-Touch®NitrileE.P.® 6034050/6034054 ● ▲ ● ▲ ● ▲ ● ▲ ▲ ▲ ▲ ▲ ▲ ●
Procedure GlovesMicro-Touch®NitraTex®Sterile-Nitrile –EACH
–PAIR
6034251/6034253 6034151/6034153
▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
latex Powder-Free Surgical GlovesEncore® 5785000-1/5785007-1 ▲ ▲ ▲ ▲ ▲ ▲ ▲
EncoreAcclaim® 5795000/5795007 ▲ ▲ ▲ ▲ ▲ ▲ ▲
Encore®Orthopaedic 5788001/5788007 ▲ ▲ ▲ ▲ ▲ ▲ ▲
NoPowder® 860260/860785 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Synthetic Powder-Free Surgical GlovesDermaPrene®IsoTouch®-Polyisoprene 20685255/20685290 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
DermaPrene®Ultra-Neoprene 851155/851890 ● ● ● ▲ ● ● ▲ ● ● ● ▲ ● ▲ ● ▲ ● ● ● ▲ ● ● ● ▲ ● ▲
aSTm TeSTInG: ● F739:Standardtestmethodforresistanceofprotectiveclothingmaterialstopermeationbyliquidsorgasesunderconditionsofcontinuouscontact ▲ D6978:Standardtestmethodforpermeationbychemotherapydrugs
Bleo
myc
inS
ulfa
te
Carb
opla
tin
Carm
ustin
e
Cisp
latin
Cycl
opho
spha
mid
e
Cyta
rabi
ne
Daca
rbaz
ine
Daun
orub
icin
Doxo
rubi
cin
Hy
droc
hlor
ide
Etop
osid
e
5-Fl
uoro
-ura
cile
Idar
ubic
in
Ifosp
ham
ide
Mec
hlor
oeth
amin
e
Mel
phal
an
Met
hrot
rexa
te
Mito
myc
ine
Mito
xant
rone
Pacl
itaxe
l
Thio
tepa
Vinc
ristin
e
cGSBCanadianGeneralStandardsBoarddeliversindependentcertificationprogramswhereproductsareassessedagainstperformanceandqualitystandards.Certificationprogramsareavoluntaryandimpartialmechanismbywhichsupplierscandemonstratethevalueoftheirgoods.
Companynameandqualifiedproductsaredisplayedontheprogramlist on-lineat:pwgsc.gc.ca/cgsb/prgsrv/certprg/program/q020_ind-e.html
onGcOfficedesNormesGénéralesduCanadaoffredesprogrammesindépendantsdecertificationquiévaluentdesproduitsàpartirdenormesderendementetdequalité.Laparticipationauxprogrammesdecertificationestvolontaire;ils’agitd’unsystèmeimpartialpermettantauxfournisseursdedémontrerlavaleurdesproduitsqu’ilsoffrent.
Entrepriseetproduitscertifiéssontaffichéssurlalisteduprogramme enligneau:pwgsc.gc.ca/cgsb/prgsrv/certprg/program/q020_ind-f.html
Tested for use with chemotherapy drugsAnsellchemotherapytestedgloveshavebeentestedeitherbyASTMF739orbyASTMD6978.SpecificchemicalresistancedataareavailableuponrequestbycontactingourCustomerServiceRepresentatives.Glovesusedforprotectionagainstchemotherapydrugsmustbeselectedspecificallyforthetypeofchemicalsused.Reviewmaterialsafetydatasheetsforthechemicalsbeingusedanddeterminetherequiredlevelof protection.
Testé pour la manipulation des médicaments de chimiothérapieLesgantsAnselltestéspourlachimiothérapieontpassélestestsASTMF739ouASTMD6978.Del’informationspécifiquesurlarésistancechimiqueestdisponiblesurdemandeencontactantnosreprésentantsauserviceàlaclientèle.Lesgantsutiliséspourlaprotectioncontrelesproduitscytotoxiquesdoiventêtresélectionnésspécifiquementselonlesproduitschimiquesutilisés.Vérifiezlesfichessignalétiquesdesproduitschimiquesutilisésafindedéterminerleniveaudebarrièredeprotectionrequis.
nom De ProDuIT coDe De ProDuIT mÉDIcamenTS chImIoThÉraPeuTIQueS TeSTÉS
Gants d’examen en latex sans poudreMicro-Touch®E.P.®Gloves 920155/920785 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Gants d’examen synthétiques sans poudreMicro-Touch®Affinity®-Néoprène 3770/3774 ● ● ● ● ● ● ● ● ●
Micro-Touch®NitraFree™-Nitrile 6034510/6034514 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Micro-Touch®Nitra-Touch®-Nitrile 6034010/6034014 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Micro-Touch®Nitrile 4000/4008 ● ● ● ▲ ● ▲ ● ▲ ● ▲ ● ● ▲ ● ▲ ● ▲ ● ● ● ● ● ● ▲ ● ▲ ●
Micro-Touch®NitrileE.P.® 6034050/6034054 ● ▲ ● ▲ ● ▲ ● ▲ ▲ ▲ ▲ ▲ ▲ ●
Gants de Procédure Micro-Touch®NitraTex®Stérile-Nitrile–UNITÉ
–PAIRE
6034251/6034253 6034151/6034153
▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Gants chirurgicaux en latex sans poudreEncore® 5785000-1/5785007-1 ▲ ▲ ▲ ▲ ▲ ▲ ▲
EncoreAcclaim® 5795000/5795007 ▲ ▲ ▲ ▲ ▲ ▲ ▲
Encore®Orthopaedic 5788001/5788007 ▲ ▲ ▲ ▲ ▲ ▲ ▲
NoPowder® 860260/860785 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Gants chirurgicaux synthétiques sans poudreDermaPrene®IsoTouch®-Polyisoprène 20685255/20685290 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
DermaPrene®Ultra-Néoprène 851155/851890 ● ● ● ▲ ● ● ▲ ● ● ● ▲ ● ▲ ● ▲ ● ● ● ▲ ● ● ● ▲ ● ▲
TeST aSTm : ● F739:Standarddespécificationquianalyselarésistanceàlaperméabilitédesmatériauxcontenusdanslesvêtementsdeprotectionaucontactcontinudeliquidesoudegazes ▲ D6978:Standarddespécificationquianalyselaperméabilitéauxproduitscytotoxiques
Sulfa
ted
eBl
eom
ycin
e
Carb
opla
tin
Carm
ustin
Cisp
latin
e
Cycl
opho
spha
mid
e
Cyta
rabi
ne
Daca
rbaz
ine
Daun
orub
icin
e
Hydr
o-ch
lorid
ede
Do
xoru
bici
n
Etop
osid
e
5-Fl
uoro
-ura
cile
Idar
ubic
in
Ifosp
ham
ide
Mec
hlor
oeth
amin
e
Mel
phal
an
Mét
hrot
rexa
te
Mito
myc
ine
Mito
xant
rone
Pacl
itaxe
l
Thio
-Tep
a
Vinc
ristin
e
Gants ansell testés pour l’utilisation en chimiothérapieansell Gloves tested for use with chemotherapy drugs
Safety and Protectionhazardous Drug DangersThehazardsencounteredduringthepreparation,administration,cleanupandgeneralhandlingofanycytotoxicdrughavebeenwelldocumented.Publicconcernismagnifiedbytheperceptionthatcancerrisksareimposeduponworkers,nursesandpharmaciststhat are involved in these procedures.
Thedangersofhandlinghazardousdrugscomefromtheirinherenttoxicityaswellasthetypeofexposurethatmayoccurintheworkplace.Todaythatworkplaceenvironmentmaybeahospitalclinic,otherpatientunit,aphysician’soffice,pharmacy,orinthepatient’shome. Chemotherapy administration has also evolved over the years. Chemotherapyagentsareadministeredviaintravenouspushaswellasacontinuousinfusionthrougha variety of implanted access devices. Exposure, to the healthcare worker or a familymemberinthehome,maybethroughingestionoffoodthatmayhavebeenexposedtothedrug,inhalationofdrugparticlesthatmaybecomeaerosolizedduringpreparation,handlingofpatientexcretaduringhomecare,ordirectskincontactofthedrug.
Studieshavebeenconductedtoassesstheindirectexposureofhealthcareworkers,i.e.nursesandpharmacists,todetermineif therewasanychromosomaldamagetotheseworkersthatpreparedandadministeredthesedrugs.Thisandotherreportspointtotheneedforexcellentexposurecontrolmeasuresandexcellentcompliancetosafehandlingprocedures.
recommendationsSimilar care should be taken in the preparation, administration and disposal ofchemotherapydrugs.Inadditiontohealthcareprofessionals,patientsandpersonsthatare directly involved in home care should also be taught these safety standards andguidelines.
ProtectionDangers des agents toxiquesLes risques encourus durant la préparation, l’administration, le nettoyage et lamanipulationdesagentscytotoxiquessontbiendocumentés.Lepublicest inquietdesrisquesdecanceraccruspourlesprofessionnelsdelasanté,infirmièresetpharmaciensqui pratiquent ces procédures.
Les dangers de la manipulation d’agents cytotoxiques proviennent de la toxicitéintrinsèqueduproduitetde l’expositionquipeutenrésulterdanslemilieudetravail.Aujourd’huilemilieudetravailpeutaussibienêtreunecliniquedel’hôpital,uneunitédesoinsauxpatients,unbureaudemédecin,unepharmacie,oumêmeledomiciledupatient. L’administrationde chimiothérapiea évoluéaucoursdesannées. Lesagentsde chimiothérapie sont administrés par voie topique, percutanée, orale, injectionintraveineusedirecteouperfusioncontinue.L’exposition,desprofessionnelsdelasantéoudesmembresdelafamilledupatient,peutseproduireparl’ingestiondenourriturequiauraitétéencontactaveclesmédicaments,parl’inhalationdeparticulesquiauraientétévaporiséeslorsdelapréparationdumédicament,parlamanipulationd’excrémentsdupatientouparlecontactdirectaveclemédicament.
Desétudesontétéélaboréespourvérifiers’ilyavaitdesdommagesauxchromosomesdestravailleursdelasanté,parexemplelesinfirmièresetlespharmaciens,suiteàl’expositionindirectelorsdelamanipulationoudel’administrationd’agentscytotoxiques.Cesétudesdémontrentlebesoindecontrôleradéquatementl’expositionetl’importancedesuivreunprocessusdemanipulationsécuritairedesagentscytotoxiques.
recommandationsCes recommandations s’appliquent autant à la préparation, qu’à l’administration etl’élimination des médicaments de chimiothérapie. Les professionnels de la santé, lespatientsetlespersonnesdirectementimpliquéesdanslessoinsauxpatientsdevraientconnaîtrecesnormesetrèglesdesécurité.
why Testing for Permeation by chemotherapy drugs?AccordingtotheWorldHealthOrganization,betweennowand2020thecancerrateisgoingtoincreaseby50%toabout15millionnewcasesayear,worldwide.
Thepredictedsharpincreaseinnewcaseswillmainlybeduetotheexistenceofsteadilyageingpopulationsinbothdevelopedanddevelopingcountries,butalsoto thecurrentprevalenceof smokingand the rise innumbersof thoseadoptingunhealthylifestyles.
Oneofthemostfrequentlyusedtreatmentsforcancerischemotherapy.Unfortunatelyitiswellknownthatcytostaticagentsarepotentiallyhazardousforthemanipulator(pharmacist,assistant,nurse,surgeon(HIPECtechnique)etc.).
Cytostaticsareknowntobe:• Mutagenic-induceorincreasegeneticmutationsbycausing changesinDNA• Carcinogenicityinanimalmodels,inpatientpopulation,orboth,• Teratogenicityorfertilityimpairmentinanimalstudiesortreatedpatients.
Someoftheotherpotentialeffectsare:• Decreaseinfertility• Foetalmalformation• Abortion• Extrauterinepregnancy• Hightoxicityforcertainorgans.
• Alwaysweargloveswhenhandlingthedrug - Avoidtouchingthedrug - Washhandsbeforeputtingglovesonandafterwearinggloves.
• Glovesusedforprotectionagainstchemotherapydrugsmustbeselected specificallyforthetypeofchemicalsused.
• Usemedicalgrade,sterileornonsterile,glovesdependingonthetechnique recommendedbyyourhealthcarefacility.
• Alwaysusepowder-freegloves. - Glovepowdersmaycontaminatechemotherapyworkarea.
• Choosealatex,nitrileorneopreneglove - Polyvinylchloride(PVC)glovesarenotrecommendedforhandling chemothapydrugs.
• Usethickglovesthatextendoverthecuffoftheprotectivegown. - Double-glovingisstronglyadvisedwhenthereisariskofexposition duringpreparationoradministrationofchemotherapydrugs. - Ifdouble-gloving,insertfirstgloveunderthecuffandplacethesecond glove over the cuff.
• Beforehandlingchemotherapydrugs, - Observeglovesforanybreakinbarrier.
• Changeglovesaftereachuse,tear,punctureormedicationspillorafter 30minutesofwear.
• Uponremoval,bothglovesneedtobeturnedinsideout - Neverflick,snap,ortossyourgloves.
• Followrecommendationsimplementedbyyourhealthcarefacilityforthe disposal of gloves.
• Toujoursutiliserdesgantspourlamanipulationdesmédicaments dechimiothérapie - Évitertoutcontactdirectavecleproduit - Selaverlesmainsavantetaprèsleportdegants.
• Lesgantsutiliséspourlaprotectioncontrelesproduitscytotoxiquesdoivent êtresélectionnésspécifiquementselonlesproduitschimiquesutilisés.
• Utiliserungantmédicalstérileounonstérileselonlatechnique recommandéeparvotrecentredesanté.
• Toujoursutiliserdesgantssanspoudre. - Lapoudredesgantspeutcontaminerlelieudetravail.
• Choisirungantenlatex,nitrileounéoprène. - Lesgantsenchloruredepolyvinyle(PVC)nesontpasrecommandéspour lamanipulationdemédicamentsdechimiothérapie.
• Porterdesgantsépaisquicouvrentbienlepoignetetlablouse. - Lorsdelapréparationetl’administrationdeproduitscytotoxiques,s’ilya undangerd’exposition,ledoublegantageestderigueur. - Sil’onsuperposelesgants,lapremièrepaireprotègelapeauetla deuxièmepairerecouvrelablouse.
• Avantdemanipulerlesproduitscytotoxiques - Vérifiersilabarrièredeprotectiondesgantsestintacte.
• Changerdegantsaprèschaqueapplication,sicontaminés,déchirés,troués ouàtoutesles30minutesd’utilisation.
• Pourretirerlesgants,tourneràl’enverssanstoucherlasurfacecontaminée - Éviterdelesclaquer,fouetterouremuerinutilement.
• Disposerdesgantsselonlesrecommandationsdevotrecentredesanté.
Pourquoi des tests spécifiques à la perméation des produits cytotoxiques ?L’Organisation mondiale de la Santé prévoit une progression du cancer de 50%d’ici2020,soitenviron15millionsdenouveauxcasdecancersparanàl’échellemondiale.
Lacausedecetteaugmentationprévuerésideprincipalementdanslevieillissementdes populations, tant dans les pays développés que dans les pays en voie dedéveloppement. La croissance du tabagisme ainsi que la généralisation demauvaiseshabitudesdevienesontpasétrangèresàlamultiplicationdescasdecancers.
La chimiothérapie figure parmi les traitements les plus fréquemment utiliséspour combattre le cancer. Or, on sait que les cytostatiques sont potentiellementdangereuxpourceluiquilesmanipule(pharmacien,assistant,infirmière,chirurgien[techniqueCHIP]etc.).
Lescytostatiquessontréputés:• mutagènes(ex.:provoquentouaugmententlesmutationsgénétiquesen changeantl’ADN)• carcinogènespourcertainsanimauxdelaboratoire,pourlespatients oulesdeux• tératogènesouproblèmesdefertilitésurlesanimauxétudiésou sur les patients traités.
Ilspeuventégalementprovoquerleseffetssecondairessuivants:• diminutiondelafécondité• malformationsfœtales• avortements• grossessesextrautérines• hautrisqued’intoxicationdecertainsorganes.
Glove characteristicsCaractéristiques du gant
Cytostatic characteristicsCaractéristiques du cytostatique
Room parameters Paramètres ambiants
Permeation rateTaux de perméation
WorkerTravailleur
OtherAutres
Exposure time Durée d’exposition
Permeationdependsonmanyparametersandthereforetheresultsobtainedcannotbeextendedtoanyothermaterial,brandorcompetitiveproduct.
Letempsdeperméationdépenddeplusieursparamètres.Lesrésultatsobtenusnepeuventêtreextrapolésàaucuneautrematière,marqueouproduitconcurrent.
Permeation : a very complex processla perméation : un processus très complexe
• Revolutionaryanti-slipcuffadherestoalltypesofgowns• Eliminatescuffroll-down
• Bandeadhésiveauxpoignetsquipermetauxgantsdetenirbienen placesurtouslestypesdeblouseschirurgicales• Élimineleproblèmed’enroulement
assurance qualité ansellansell Quality assurance
Surgical GlovesIn addition to the barrier protection and infection prevention benefits that Ansell surgical gloves offer, each glove provides unique features.
Gants chirurgicauxChaque gant chirurgical Ansell possède des caractéristiques propres.
• Polyisoprène,sanspoudre• Réduitlesrisquesd’allergiedeTypeI• Couleurverte• Finilisse• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:306mm(12”)• Épaisseur(simple)boutdedoigts:0,23mm(9mil)
Derma Prene® ISoTouch®
• Polyisoprene,powder-free• ReducestheriskoftypeIallergy• Greencolor• Smoothfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:306mm(12”)• Fingertipsthickness(single):0.23mm(9mils)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
20685255 5½ 20685275 7½
20685260 6 20685280 8
20685265 6½ 20685285 8½
20685270 7 20685290 9
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisse
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
5785000-1 5½ 5785004-1 7½
5785001-1 6 5785005-1 8
5785002-1 6½ 5785006-1 8½
5785003-1 7 5785007-1 9
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisseTheselatexglovescontain50microgramsorlessoftotalwater-extractibleproteinpergram.*Cesgantsenlatexcontiennent50microgrammesoumoinsdeprotéinestotalementextractiblesdel’eaupargramme.*
encore®
• Latex,lowprotein,powder-free• Creamcolor• Texturedfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:297mm(11.7”)• Fingertipsthickness(single):0.23mm(9mils)
• Latex,faibleenprotéines,sanspoudre• Couleurcrème• Finitexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:297mm(11,7”)• Épaisseur(simple)boutdedoigts:0,23mm(9mil)
CAUTION:Theseproductscontainnaturalrubberlatexwhichmaycauseallergicreactions.*CAUTION:Safeuseoftheselatexglovesbyoronlatex-sensitizedindividualshasnotbeenestablished.ATTENTION:Cesproduitscontiennentdulatexdecaoutchoucnaturelpouvantprovoquerdesréactionsallergiques.*ATTENTION:L’utilisationsécuritairedecesgantsenlatexparousurdespersonnessensiblesaulatexn’apasétéétablie.
encore acclaIm®
• Latex,lowprotein,powder-free• Creamcolor• Smoothfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:297mm(11.7”)• Fingertipsthickness(single):0.25mm(10mils)
• Latex,faibleenprotéines,sanspoudre• Couleurcrème• Finilisse• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:297mm(11,7”)• Épaisseur(simple)boutdedoigts:0,25mm(10mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
5795000 5½ 5795004 7½
5795001 6 5795005 8
5795002 6½ 5795006 8½
5795003 7 5795007 9
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisseTheselatexglovescontain50microgramsorlessoftotalwater-extractibleproteinpergram.*Cesgantsenlatexcontiennent50microgrammesoumoinsdeprotéinestotalementextractiblesdel’eaupargramme.*
encore® orThoPaeDIc• Latex,lowprotein,powder-free• Browncolor• Texturedfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:297mm(11.7”)• Fingertipsthickness(single):0.33mm(13mils)
• Latex,faibleenprotéines,sanspoudre• Couleurbrune• Finitexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:297mm(11,7”)• Épaisseur(simple)boutdedoigts:0,33mm(13mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
5788001 6 5788005 8
5788002 6½ 5788006 8½
5788003 7 5788007 9
5788004 7½
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisseTheselatexglovescontain50microgramsorlessoftotalwater-extractibleproteinpergram.*Cesgantsenlatexcontiennent50microgrammesoumoinsdeprotéinestotalementextractiblesdel’eaupargramme.*
CAUTION:Thisproductcontainsnaturalrubberlatexwhichmaycauseallergicreactions.ATTENTION:Cesproduitscontiennentdulatexdecaoutchoucnaturelpouvantprovoquerdesréactionsallergiques.
no PowDer®
• Latex,powder-free• Creamcolor• Texturedfinish• TestedforusewithchemotherapydrugsASTMF739• Length:302mm(11.9”)• Fingertipsthickness(single):0.20mm(8mils)
• Latex,sanspoudre• Couleurcrème• Finitexturé• Testépourl’utilisationenchimiothérapieASTMF739• Longueur:302mm(11,9”)• Épaisseur(simple)boutdedoigts:0,20mm(8mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
860260 6 860575 7½
860365 6½ 860680 8
860470 7 860785 8½
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisse
Derma Prene® ulTra• Neoprene,powder-free• Chemicalaccelerator-free• ReducestheriskofTypeIVandIallergies• Greencolor• Smoothfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:308mm(12.1”)• Fingertipsthickness(single):0.20mm(8mils)
• Néoprène,sanspoudre• Sansaccélérateurschimiques• Réduitlesrisquesd’allergiedeTypeIVetI• Couleurverte• Finilisse• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:308mm(12,1”)• Épaisseur(simple)boutdedoigts:0,20mm(8mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
851155 5½ 851575 7½
851260 6 851680 8
851365 6½ 851785 8½
851470 7 851890 9
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisse
Powder-Free examination GlovesInadditiontotheinfectionpreventionbenefitsthatAnsellexamglovesoffer,each glove provides unique features.
Gants d’examen sans poudreChaquegantd’examenAnsellpossèdedescaractéristiquespropres.
mIcro-Touch® aFFInITy®
• Neoprene• ReducestheriskofTypeIallergy• Greencolor• Texturedfingertips• TestedforusewithchemotherapydrugsASTMF739• Length:239mm(9.4”)• Fingertipsthickness(single):0.18mm(7mils)
• Néoprène• Réduitlesrisquesd’allergiedeTypeI• Couleurverte• Boutdesdoigtstexturé• Testépourl’utilisationenchimiothérapieASTMF739• Longueur:239mm(9,4”)• Épaisseur(simple)boutdedoigts:0,18mm(7mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
3770 XS/TP 3773 L/G
3771 S/P 3774 XL/TG
3772 M
100Gloves/DispenserBox–10Boxes/Case 100gants/boîtedistributrice–10boîtes/caisse
mIcro-Touch® nITrIle e.P.®
• Nitrile• ReducestheriskofTypeIallergy• Bluecolor• Texturedfingertips• TestedforusewithchemotherapydrugsASTMD6978• Length:295mm(11.6”)• Fingertipsthickness(single):0.12mm(4.7mils)
• Nitrile• Réduitlesrisquesd’allergiedeTypeI• Couleurbleue• Boutdesdoigtstexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:295mm(11,6”)• Épaisseur(simple)boutdedoigts:0,12mm(4,7mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
6034050 XS/TP 6034053 L/G
6034051 S/P 6034054 XL/TG
6034052 M
100Gloves/DispenserBox–10Boxes/Case 100gants/boîtedistributrice–10boîtes/caisse
mIcro-Touch® nITrIle• Nitrile• ReducestheriskofTypeIallergy• Bluecolor• Texturedfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:239mm(9.4”)• Fingertipsthickness(single):0.12mm(4.7mils)
• Nitrile• Réduitlesrisquesd’allergiedeTypeI• Couleurbleue• Finitexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:239mm(9,4”)• Épaisseur(simple)boutdedoigts:0,12mm(4,7mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
4000 XS/TP 4006 L/G
4002 S/P 4008 XL/TG
4004 M
100Gloves/DispenserBox–10Boxes/Case 100gants/boîtedistributrice–10boîtes/caisse
• Nitrile• ReducestheriskofTypeIallergy• Bluecolor• Texturedfingertips• TestedforusewithchemotherapydrugsASTMD6978• Length:245mm(9.6”)• Fingertipsthickness(single):0.16mm(6.3mils)• CGSBcertified
• Nitrile• Réduitlesrisquesd’allergiedeTypeI• Couleurbleue• Boutdesdoigtstexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:245mm(9,6”)• Épaisseur(simple)boutdedoigts:0,16mm(6,3mil)• Certifiéparl’ONGC
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
6034010 XS/TP 6034013 L/G
6034011 S/P 6034014 XL/TG
6034012 M
100Gloves/DispenserBox–10Boxes/Case 100gants/boîtedistributrice–10boîtes/caisse
mIcro-Touch® nITra-Touch®
mIcro-Touch® nITraTex® STerIleProcedure Gloves• Nitrile• ReducestheriskofTypeIallergy• Bluecolor• Texturedfingertips• TestedforusewithchemotherapydrugsASTMD6978• Length:295mm(11.6”)• Fingertipsthickness(single):0.12mm(4.7mils)
Gants de procédure• Nitrile• Réduitlesrisquesd’allergiedeTypeI• Couleurbleue• Boutdesdoigtstexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:295mm(11,6”)• Épaisseur(simple)boutdedoigts:0,12mm(4,7mil)
Single with Innerwrap / À l’unité avec enveloppe interne
catalog numbers / no de catalogue Sizes / Grandeurs
6034251 S/P
6034252 M
6034253 L/G
6034254 XL/TG
1SterileGlove/Package–100Gloves/DispenserBox–4Boxes/Case/1gantstérile/emballage–100gants/boîtedistributrice–4boîtes/caisse
Pair with Innerwrap / Paire avec enveloppe interne
catalog numbers / no de catalogue Sizes / Grandeurs
6034151 S/P
6034152 M
6034153 L/G
6034154 XL/TG
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisse
CAUTION:Thisproductcontainsnaturalrubberlatexwhichmaycauseallergicreactions.ATTENTION:Cesproduitscontiennentdulatexdecaoutchoucnaturelpouvantprovoquerdesréactionsallergiques.
mIcro-Touch® e.P.® GloveS• Creamcolor• Handspecific• TestedforusewithchemotherapydrugsASTMF739• Length:305mm(12”)• Fingertipsthickness(single):0.24mm(9.5mils)
• Couleurcrème• Maindroite,maingauche• Testépourl’utilisationenchimiothérapieASTMF739• Longueur:305mm(12”)• Épaisseur(simple)boutdedoigts:0,24mm(9.5mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
920155 XS/TP 920575 M
920365 S/P 920785 L/G
1Pair/Package–25Pairs/DispenserBox,4Boxes/Case 1paire/emballage–25paires/boîtedistributrice,4boîtes/caisse
• Nitrile• Chemicalaccelerator-free*• ReducestheriskofTypeIV(chemical)
andI(latex)allergies• Pinkcolor• Texturedfingertips• TestedforusewithchemotherapydrugsASTMD6978• Length:240mm(9.4”)• Fingertipsthickness(single):0.16mm(6.3mils)
• Nitrile• Sansaccélérateurschimiques*• Réduitlesrisquesd’allergiedeTypeIV(chimique)etI(latex)• Couleurrose• Boutdesdoigtstexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:240mm(9,4”)• Épaisseur(simple)boutdedoigts:0,16mm(6,3mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
6034510 XS/TP 6034513 L/G
6034511 S/P 6034514 XL/TG
6034512 M
100Gloves/DispenserBox–10Boxes/Case 100gants/boîtedistributrice–10boîtes/caisse*Doesnotcontainsulphur-basedacceleratorssuchasthiurams,carbamates,thiazoles,guanidineorthioureas.*Necontientpasd’accélérateursàbasedesulfuretelsquethiurame,carbamate,thiazole,guanidineouthiocarbamide.
mIcro-Touch® nITraFree™
AnsellisproudtopartnerwithSusanG.KomenfortheCure® to unite in the fight against breast cancer.
Ansellestheureuxd’annoncersonpartenariataveclafondationSusanG.KomenfortheCure® dans sa lutte contre le cancer du sein.
latex latex
Synthetic – SynthétiqueSynthetic – Synthétique
Surgical GlovesIn addition to the barrier protection and infection prevention benefits that Ansell surgical gloves offer, each glove provides unique features.
Gants chirurgicauxChaque gant chirurgical Ansell possède des caractéristiques propres.
• Polyisoprène,sanspoudre• Réduitlesrisquesd’allergiedeTypeI• Couleurverte• Finilisse• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:306mm(12”)• Épaisseur(simple)boutdedoigts:0,23mm(9mil)
Derma Prene® ISoTouch®
• Polyisoprene,powder-free• ReducestheriskoftypeIallergy• Greencolor• Smoothfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:306mm(12”)• Fingertipsthickness(single):0.23mm(9mils)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
20685255 5½ 20685275 7½
20685260 6 20685280 8
20685265 6½ 20685285 8½
20685270 7 20685290 9
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisse
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
5785000-1 5½ 5785004-1 7½
5785001-1 6 5785005-1 8
5785002-1 6½ 5785006-1 8½
5785003-1 7 5785007-1 9
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisseTheselatexglovescontain50microgramsorlessoftotalwater-extractibleproteinpergram.*Cesgantsenlatexcontiennent50microgrammesoumoinsdeprotéinestotalementextractiblesdel’eaupargramme.*
encore®
• Latex,lowprotein,powder-free• Creamcolor• Texturedfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:297mm(11.7”)• Fingertipsthickness(single):0.23mm(9mils)
• Latex,faibleenprotéines,sanspoudre• Couleurcrème• Finitexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:297mm(11,7”)• Épaisseur(simple)boutdedoigts:0,23mm(9mil)
CAUTION:Theseproductscontainnaturalrubberlatexwhichmaycauseallergicreactions.*CAUTION:Safeuseoftheselatexglovesbyoronlatex-sensitizedindividualshasnotbeenestablished.ATTENTION:Cesproduitscontiennentdulatexdecaoutchoucnaturelpouvantprovoquerdesréactionsallergiques.*ATTENTION:L’utilisationsécuritairedecesgantsenlatexparousurdespersonnessensiblesaulatexn’apasétéétablie.
encore acclaIm®
• Latex,lowprotein,powder-free• Creamcolor• Smoothfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:297mm(11.7”)• Fingertipsthickness(single):0.25mm(10mils)
• Latex,faibleenprotéines,sanspoudre• Couleurcrème• Finilisse• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:297mm(11,7”)• Épaisseur(simple)boutdedoigts:0,25mm(10mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
5795000 5½ 5795004 7½
5795001 6 5795005 8
5795002 6½ 5795006 8½
5795003 7 5795007 9
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisseTheselatexglovescontain50microgramsorlessoftotalwater-extractibleproteinpergram.*Cesgantsenlatexcontiennent50microgrammesoumoinsdeprotéinestotalementextractiblesdel’eaupargramme.*
encore® orThoPaeDIc• Latex,lowprotein,powder-free• Browncolor• Texturedfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:297mm(11.7”)• Fingertipsthickness(single):0.33mm(13mils)
• Latex,faibleenprotéines,sanspoudre• Couleurbrune• Finitexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:297mm(11,7”)• Épaisseur(simple)boutdedoigts:0,33mm(13mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
5788001 6 5788005 8
5788002 6½ 5788006 8½
5788003 7 5788007 9
5788004 7½
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisseTheselatexglovescontain50microgramsorlessoftotalwater-extractibleproteinpergram.*Cesgantsenlatexcontiennent50microgrammesoumoinsdeprotéinestotalementextractiblesdel’eaupargramme.*
CAUTION:Thisproductcontainsnaturalrubberlatexwhichmaycauseallergicreactions.ATTENTION:Cesproduitscontiennentdulatexdecaoutchoucnaturelpouvantprovoquerdesréactionsallergiques.
no PowDer®
• Latex,powder-free• Creamcolor• Texturedfinish• TestedforusewithchemotherapydrugsASTMF739• Length:302mm(11.9”)• Fingertipsthickness(single):0.20mm(8mils)
• Latex,sanspoudre• Couleurcrème• Finitexturé• Testépourl’utilisationenchimiothérapieASTMF739• Longueur:302mm(11,9”)• Épaisseur(simple)boutdedoigts:0,20mm(8mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
860260 6 860575 7½
860365 6½ 860680 8
860470 7 860785 8½
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisse
Derma Prene® ulTra• Neoprene,powder-free• Chemicalaccelerator-free• ReducestheriskofTypeIVandIallergies• Greencolor• Smoothfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:308mm(12.1”)• Fingertipsthickness(single):0.20mm(8mils)
• Néoprène,sanspoudre• Sansaccélérateurschimiques• Réduitlesrisquesd’allergiedeTypeIVetI• Couleurverte• Finilisse• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:308mm(12,1”)• Épaisseur(simple)boutdedoigts:0,20mm(8mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
851155 5½ 851575 7½
851260 6 851680 8
851365 6½ 851785 8½
851470 7 851890 9
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisse
Powder-Free examination GlovesInadditiontotheinfectionpreventionbenefitsthatAnsellexamglovesoffer,each glove provides unique features.
Gants d’examen sans poudreChaquegantd’examenAnsellpossèdedescaractéristiquespropres.
mIcro-Touch® aFFInITy®
• Neoprene• ReducestheriskofTypeIallergy• Greencolor• Texturedfingertips• TestedforusewithchemotherapydrugsASTMF739• Length:239mm(9.4”)• Fingertipsthickness(single):0.18mm(7mils)
• Néoprène• Réduitlesrisquesd’allergiedeTypeI• Couleurverte• Boutdesdoigtstexturé• Testépourl’utilisationenchimiothérapieASTMF739• Longueur:239mm(9,4”)• Épaisseur(simple)boutdedoigts:0,18mm(7mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
3770 XS/TP 3773 L/G
3771 S/P 3774 XL/TG
3772 M
100Gloves/DispenserBox–10Boxes/Case 100gants/boîtedistributrice–10boîtes/caisse
mIcro-Touch® nITrIle e.P.®
• Nitrile• ReducestheriskofTypeIallergy• Bluecolor• Texturedfingertips• TestedforusewithchemotherapydrugsASTMD6978• Length:295mm(11.6”)• Fingertipsthickness(single):0.12mm(4.7mils)
• Nitrile• Réduitlesrisquesd’allergiedeTypeI• Couleurbleue• Boutdesdoigtstexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:295mm(11,6”)• Épaisseur(simple)boutdedoigts:0,12mm(4,7mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
6034050 XS/TP 6034053 L/G
6034051 S/P 6034054 XL/TG
6034052 M
100Gloves/DispenserBox–10Boxes/Case 100gants/boîtedistributrice–10boîtes/caisse
mIcro-Touch® nITrIle• Nitrile• ReducestheriskofTypeIallergy• Bluecolor• Texturedfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:239mm(9.4”)• Fingertipsthickness(single):0.12mm(4.7mils)
• Nitrile• Réduitlesrisquesd’allergiedeTypeI• Couleurbleue• Finitexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:239mm(9,4”)• Épaisseur(simple)boutdedoigts:0,12mm(4,7mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
4000 XS/TP 4006 L/G
4002 S/P 4008 XL/TG
4004 M
100Gloves/DispenserBox–10Boxes/Case 100gants/boîtedistributrice–10boîtes/caisse
• Nitrile• ReducestheriskofTypeIallergy• Bluecolor• Texturedfingertips• TestedforusewithchemotherapydrugsASTMD6978• Length:245mm(9.6”)• Fingertipsthickness(single):0.16mm(6.3mils)• CGSBcertified
• Nitrile• Réduitlesrisquesd’allergiedeTypeI• Couleurbleue• Boutdesdoigtstexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:245mm(9,6”)• Épaisseur(simple)boutdedoigts:0,16mm(6,3mil)• Certifiéparl’ONGC
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
6034010 XS/TP 6034013 L/G
6034011 S/P 6034014 XL/TG
6034012 M
100Gloves/DispenserBox–10Boxes/Case 100gants/boîtedistributrice–10boîtes/caisse
mIcro-Touch® nITra-Touch®
mIcro-Touch® nITraTex® STerIleProcedure Gloves• Nitrile• ReducestheriskofTypeIallergy• Bluecolor• Texturedfingertips• TestedforusewithchemotherapydrugsASTMD6978• Length:295mm(11.6”)• Fingertipsthickness(single):0.12mm(4.7mils)
Gants de procédure• Nitrile• Réduitlesrisquesd’allergiedeTypeI• Couleurbleue• Boutdesdoigtstexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:295mm(11,6”)• Épaisseur(simple)boutdedoigts:0,12mm(4,7mil)
Single with Innerwrap / À l’unité avec enveloppe interne
catalog numbers / no de catalogue Sizes / Grandeurs
6034251 S/P
6034252 M
6034253 L/G
6034254 XL/TG
1SterileGlove/Package–100Gloves/DispenserBox–4Boxes/Case/1gantstérile/emballage–100gants/boîtedistributrice–4boîtes/caisse
Pair with Innerwrap / Paire avec enveloppe interne
catalog numbers / no de catalogue Sizes / Grandeurs
6034151 S/P
6034152 M
6034153 L/G
6034154 XL/TG
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisse
CAUTION:Thisproductcontainsnaturalrubberlatexwhichmaycauseallergicreactions.ATTENTION:Cesproduitscontiennentdulatexdecaoutchoucnaturelpouvantprovoquerdesréactionsallergiques.
mIcro-Touch® e.P.® GloveS• Creamcolor• Handspecific• TestedforusewithchemotherapydrugsASTMF739• Length:305mm(12”)• Fingertipsthickness(single):0.24mm(9.5mils)
• Couleurcrème• Maindroite,maingauche• Testépourl’utilisationenchimiothérapieASTMF739• Longueur:305mm(12”)• Épaisseur(simple)boutdedoigts:0,24mm(9.5mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
920155 XS/TP 920575 M
920365 S/P 920785 L/G
1Pair/Package–25Pairs/DispenserBox,4Boxes/Case 1paire/emballage–25paires/boîtedistributrice,4boîtes/caisse
• Nitrile• Chemicalaccelerator-free*• ReducestheriskofTypeIV(chemical)
andI(latex)allergies• Pinkcolor• Texturedfingertips• TestedforusewithchemotherapydrugsASTMD6978• Length:240mm(9.4”)• Fingertipsthickness(single):0.16mm(6.3mils)
• Nitrile• Sansaccélérateurschimiques*• Réduitlesrisquesd’allergiedeTypeIV(chimique)etI(latex)• Couleurrose• Boutdesdoigtstexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:240mm(9,4”)• Épaisseur(simple)boutdedoigts:0,16mm(6,3mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
6034510 XS/TP 6034513 L/G
6034511 S/P 6034514 XL/TG
6034512 M
100Gloves/DispenserBox–10Boxes/Case 100gants/boîtedistributrice–10boîtes/caisse*Doesnotcontainsulphur-basedacceleratorssuchasthiurams,carbamates,thiazoles,guanidineorthioureas.*Necontientpasd’accélérateursàbasedesulfuretelsquethiurame,carbamate,thiazole,guanidineouthiocarbamide.
mIcro-Touch® nITraFree™
AnsellisproudtopartnerwithSusanG.KomenfortheCure® to unite in the fight against breast cancer.
Ansellestheureuxd’annoncersonpartenariataveclafondationSusanG.KomenfortheCure® dans sa lutte contre le cancer du sein.
latex latex
Synthetic – SynthétiqueSynthetic – Synthétique
Surgical GlovesIn addition to the barrier protection and infection prevention benefits that Ansell surgical gloves offer, each glove provides unique features.
Gants chirurgicauxChaque gant chirurgical Ansell possède des caractéristiques propres.
• Polyisoprène,sanspoudre• Réduitlesrisquesd’allergiedeTypeI• Couleurverte• Finilisse• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:306mm(12”)• Épaisseur(simple)boutdedoigts:0,23mm(9mil)
Derma Prene® ISoTouch®
• Polyisoprene,powder-free• ReducestheriskoftypeIallergy• Greencolor• Smoothfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:306mm(12”)• Fingertipsthickness(single):0.23mm(9mils)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
20685255 5½ 20685275 7½
20685260 6 20685280 8
20685265 6½ 20685285 8½
20685270 7 20685290 9
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisse
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
5785000-1 5½ 5785004-1 7½
5785001-1 6 5785005-1 8
5785002-1 6½ 5785006-1 8½
5785003-1 7 5785007-1 9
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisseTheselatexglovescontain50microgramsorlessoftotalwater-extractibleproteinpergram.*Cesgantsenlatexcontiennent50microgrammesoumoinsdeprotéinestotalementextractiblesdel’eaupargramme.*
encore®
• Latex,lowprotein,powder-free• Creamcolor• Texturedfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:297mm(11.7”)• Fingertipsthickness(single):0.23mm(9mils)
• Latex,faibleenprotéines,sanspoudre• Couleurcrème• Finitexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:297mm(11,7”)• Épaisseur(simple)boutdedoigts:0,23mm(9mil)
CAUTION:Theseproductscontainnaturalrubberlatexwhichmaycauseallergicreactions.*CAUTION:Safeuseoftheselatexglovesbyoronlatex-sensitizedindividualshasnotbeenestablished.ATTENTION:Cesproduitscontiennentdulatexdecaoutchoucnaturelpouvantprovoquerdesréactionsallergiques.*ATTENTION:L’utilisationsécuritairedecesgantsenlatexparousurdespersonnessensiblesaulatexn’apasétéétablie.
encore acclaIm®
• Latex,lowprotein,powder-free• Creamcolor• Smoothfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:297mm(11.7”)• Fingertipsthickness(single):0.25mm(10mils)
• Latex,faibleenprotéines,sanspoudre• Couleurcrème• Finilisse• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:297mm(11,7”)• Épaisseur(simple)boutdedoigts:0,25mm(10mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
5795000 5½ 5795004 7½
5795001 6 5795005 8
5795002 6½ 5795006 8½
5795003 7 5795007 9
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisseTheselatexglovescontain50microgramsorlessoftotalwater-extractibleproteinpergram.*Cesgantsenlatexcontiennent50microgrammesoumoinsdeprotéinestotalementextractiblesdel’eaupargramme.*
encore® orThoPaeDIc• Latex,lowprotein,powder-free• Browncolor• Texturedfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:297mm(11.7”)• Fingertipsthickness(single):0.33mm(13mils)
• Latex,faibleenprotéines,sanspoudre• Couleurbrune• Finitexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:297mm(11,7”)• Épaisseur(simple)boutdedoigts:0,33mm(13mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
5788001 6 5788005 8
5788002 6½ 5788006 8½
5788003 7 5788007 9
5788004 7½
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisseTheselatexglovescontain50microgramsorlessoftotalwater-extractibleproteinpergram.*Cesgantsenlatexcontiennent50microgrammesoumoinsdeprotéinestotalementextractiblesdel’eaupargramme.*
CAUTION:Thisproductcontainsnaturalrubberlatexwhichmaycauseallergicreactions.ATTENTION:Cesproduitscontiennentdulatexdecaoutchoucnaturelpouvantprovoquerdesréactionsallergiques.
no PowDer®
• Latex,powder-free• Creamcolor• Texturedfinish• TestedforusewithchemotherapydrugsASTMF739• Length:302mm(11.9”)• Fingertipsthickness(single):0.20mm(8mils)
• Latex,sanspoudre• Couleurcrème• Finitexturé• Testépourl’utilisationenchimiothérapieASTMF739• Longueur:302mm(11,9”)• Épaisseur(simple)boutdedoigts:0,20mm(8mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
860260 6 860575 7½
860365 6½ 860680 8
860470 7 860785 8½
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisse
Derma Prene® ulTra• Neoprene,powder-free• Chemicalaccelerator-free• ReducestheriskofTypeIVandIallergies• Greencolor• Smoothfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:308mm(12.1”)• Fingertipsthickness(single):0.20mm(8mils)
• Néoprène,sanspoudre• Sansaccélérateurschimiques• Réduitlesrisquesd’allergiedeTypeIVetI• Couleurverte• Finilisse• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:308mm(12,1”)• Épaisseur(simple)boutdedoigts:0,20mm(8mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
851155 5½ 851575 7½
851260 6 851680 8
851365 6½ 851785 8½
851470 7 851890 9
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisse
Powder-Free examination GlovesInadditiontotheinfectionpreventionbenefitsthatAnsellexamglovesoffer,each glove provides unique features.
Gants d’examen sans poudreChaquegantd’examenAnsellpossèdedescaractéristiquespropres.
mIcro-Touch® aFFInITy®
• Neoprene• ReducestheriskofTypeIallergy• Greencolor• Texturedfingertips• TestedforusewithchemotherapydrugsASTMF739• Length:239mm(9.4”)• Fingertipsthickness(single):0.18mm(7mils)
• Néoprène• Réduitlesrisquesd’allergiedeTypeI• Couleurverte• Boutdesdoigtstexturé• Testépourl’utilisationenchimiothérapieASTMF739• Longueur:239mm(9,4”)• Épaisseur(simple)boutdedoigts:0,18mm(7mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
3770 XS/TP 3773 L/G
3771 S/P 3774 XL/TG
3772 M
100Gloves/DispenserBox–10Boxes/Case 100gants/boîtedistributrice–10boîtes/caisse
mIcro-Touch® nITrIle e.P.®
• Nitrile• ReducestheriskofTypeIallergy• Bluecolor• Texturedfingertips• TestedforusewithchemotherapydrugsASTMD6978• Length:295mm(11.6”)• Fingertipsthickness(single):0.12mm(4.7mils)
• Nitrile• Réduitlesrisquesd’allergiedeTypeI• Couleurbleue• Boutdesdoigtstexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:295mm(11,6”)• Épaisseur(simple)boutdedoigts:0,12mm(4,7mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
6034050 XS/TP 6034053 L/G
6034051 S/P 6034054 XL/TG
6034052 M
100Gloves/DispenserBox–10Boxes/Case 100gants/boîtedistributrice–10boîtes/caisse
mIcro-Touch® nITrIle• Nitrile• ReducestheriskofTypeIallergy• Bluecolor• Texturedfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:239mm(9.4”)• Fingertipsthickness(single):0.12mm(4.7mils)
• Nitrile• Réduitlesrisquesd’allergiedeTypeI• Couleurbleue• Finitexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:239mm(9,4”)• Épaisseur(simple)boutdedoigts:0,12mm(4,7mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
4000 XS/TP 4006 L/G
4002 S/P 4008 XL/TG
4004 M
100Gloves/DispenserBox–10Boxes/Case 100gants/boîtedistributrice–10boîtes/caisse
• Nitrile• ReducestheriskofTypeIallergy• Bluecolor• Texturedfingertips• TestedforusewithchemotherapydrugsASTMD6978• Length:245mm(9.6”)• Fingertipsthickness(single):0.16mm(6.3mils)• CGSBcertified
• Nitrile• Réduitlesrisquesd’allergiedeTypeI• Couleurbleue• Boutdesdoigtstexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:245mm(9,6”)• Épaisseur(simple)boutdedoigts:0,16mm(6,3mil)• Certifiéparl’ONGC
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
6034010 XS/TP 6034013 L/G
6034011 S/P 6034014 XL/TG
6034012 M
100Gloves/DispenserBox–10Boxes/Case 100gants/boîtedistributrice–10boîtes/caisse
mIcro-Touch® nITra-Touch®
mIcro-Touch® nITraTex® STerIleProcedure Gloves• Nitrile• ReducestheriskofTypeIallergy• Bluecolor• Texturedfingertips• TestedforusewithchemotherapydrugsASTMD6978• Length:295mm(11.6”)• Fingertipsthickness(single):0.12mm(4.7mils)
Gants de procédure• Nitrile• Réduitlesrisquesd’allergiedeTypeI• Couleurbleue• Boutdesdoigtstexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:295mm(11,6”)• Épaisseur(simple)boutdedoigts:0,12mm(4,7mil)
Single with Innerwrap / À l’unité avec enveloppe interne
catalog numbers / no de catalogue Sizes / Grandeurs
6034251 S/P
6034252 M
6034253 L/G
6034254 XL/TG
1SterileGlove/Package–100Gloves/DispenserBox–4Boxes/Case/1gantstérile/emballage–100gants/boîtedistributrice–4boîtes/caisse
Pair with Innerwrap / Paire avec enveloppe interne
catalog numbers / no de catalogue Sizes / Grandeurs
6034151 S/P
6034152 M
6034153 L/G
6034154 XL/TG
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisse
CAUTION:Thisproductcontainsnaturalrubberlatexwhichmaycauseallergicreactions.ATTENTION:Cesproduitscontiennentdulatexdecaoutchoucnaturelpouvantprovoquerdesréactionsallergiques.
mIcro-Touch® e.P.® GloveS• Creamcolor• Handspecific• TestedforusewithchemotherapydrugsASTMF739• Length:305mm(12”)• Fingertipsthickness(single):0.24mm(9.5mils)
• Couleurcrème• Maindroite,maingauche• Testépourl’utilisationenchimiothérapieASTMF739• Longueur:305mm(12”)• Épaisseur(simple)boutdedoigts:0,24mm(9.5mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
920155 XS/TP 920575 M
920365 S/P 920785 L/G
1Pair/Package–25Pairs/DispenserBox,4Boxes/Case 1paire/emballage–25paires/boîtedistributrice,4boîtes/caisse
• Nitrile• Chemicalaccelerator-free*• ReducestheriskofTypeIV(chemical)
andI(latex)allergies• Pinkcolor• Texturedfingertips• TestedforusewithchemotherapydrugsASTMD6978• Length:240mm(9.4”)• Fingertipsthickness(single):0.16mm(6.3mils)
• Nitrile• Sansaccélérateurschimiques*• Réduitlesrisquesd’allergiedeTypeIV(chimique)etI(latex)• Couleurrose• Boutdesdoigtstexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:240mm(9,4”)• Épaisseur(simple)boutdedoigts:0,16mm(6,3mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
6034510 XS/TP 6034513 L/G
6034511 S/P 6034514 XL/TG
6034512 M
100Gloves/DispenserBox–10Boxes/Case 100gants/boîtedistributrice–10boîtes/caisse*Doesnotcontainsulphur-basedacceleratorssuchasthiurams,carbamates,thiazoles,guanidineorthioureas.*Necontientpasd’accélérateursàbasedesulfuretelsquethiurame,carbamate,thiazole,guanidineouthiocarbamide.
mIcro-Touch® nITraFree™
AnsellisproudtopartnerwithSusanG.KomenfortheCure® to unite in the fight against breast cancer.
Ansellestheureuxd’annoncersonpartenariataveclafondationSusanG.KomenfortheCure® dans sa lutte contre le cancer du sein.
latex latex
Synthetic – SynthétiqueSynthetic – Synthétique
Surgical GlovesIn addition to the barrier protection and infection prevention benefits that Ansell surgical gloves offer, each glove provides unique features.
Gants chirurgicauxChaque gant chirurgical Ansell possède des caractéristiques propres.
• Polyisoprène,sanspoudre• Réduitlesrisquesd’allergiedeTypeI• Couleurverte• Finilisse• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:306mm(12”)• Épaisseur(simple)boutdedoigts:0,23mm(9mil)
Derma Prene® ISoTouch®
• Polyisoprene,powder-free• ReducestheriskoftypeIallergy• Greencolor• Smoothfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:306mm(12”)• Fingertipsthickness(single):0.23mm(9mils)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
20685255 5½ 20685275 7½
20685260 6 20685280 8
20685265 6½ 20685285 8½
20685270 7 20685290 9
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisse
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
5785000-1 5½ 5785004-1 7½
5785001-1 6 5785005-1 8
5785002-1 6½ 5785006-1 8½
5785003-1 7 5785007-1 9
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisseTheselatexglovescontain50microgramsorlessoftotalwater-extractibleproteinpergram.*Cesgantsenlatexcontiennent50microgrammesoumoinsdeprotéinestotalementextractiblesdel’eaupargramme.*
encore®
• Latex,lowprotein,powder-free• Creamcolor• Texturedfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:297mm(11.7”)• Fingertipsthickness(single):0.23mm(9mils)
• Latex,faibleenprotéines,sanspoudre• Couleurcrème• Finitexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:297mm(11,7”)• Épaisseur(simple)boutdedoigts:0,23mm(9mil)
CAUTION:Theseproductscontainnaturalrubberlatexwhichmaycauseallergicreactions.*CAUTION:Safeuseoftheselatexglovesbyoronlatex-sensitizedindividualshasnotbeenestablished.ATTENTION:Cesproduitscontiennentdulatexdecaoutchoucnaturelpouvantprovoquerdesréactionsallergiques.*ATTENTION:L’utilisationsécuritairedecesgantsenlatexparousurdespersonnessensiblesaulatexn’apasétéétablie.
encore acclaIm®
• Latex,lowprotein,powder-free• Creamcolor• Smoothfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:297mm(11.7”)• Fingertipsthickness(single):0.25mm(10mils)
• Latex,faibleenprotéines,sanspoudre• Couleurcrème• Finilisse• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:297mm(11,7”)• Épaisseur(simple)boutdedoigts:0,25mm(10mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
5795000 5½ 5795004 7½
5795001 6 5795005 8
5795002 6½ 5795006 8½
5795003 7 5795007 9
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisseTheselatexglovescontain50microgramsorlessoftotalwater-extractibleproteinpergram.*Cesgantsenlatexcontiennent50microgrammesoumoinsdeprotéinestotalementextractiblesdel’eaupargramme.*
encore® orThoPaeDIc• Latex,lowprotein,powder-free• Browncolor• Texturedfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:297mm(11.7”)• Fingertipsthickness(single):0.33mm(13mils)
• Latex,faibleenprotéines,sanspoudre• Couleurbrune• Finitexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:297mm(11,7”)• Épaisseur(simple)boutdedoigts:0,33mm(13mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
5788001 6 5788005 8
5788002 6½ 5788006 8½
5788003 7 5788007 9
5788004 7½
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisseTheselatexglovescontain50microgramsorlessoftotalwater-extractibleproteinpergram.*Cesgantsenlatexcontiennent50microgrammesoumoinsdeprotéinestotalementextractiblesdel’eaupargramme.*
CAUTION:Thisproductcontainsnaturalrubberlatexwhichmaycauseallergicreactions.ATTENTION:Cesproduitscontiennentdulatexdecaoutchoucnaturelpouvantprovoquerdesréactionsallergiques.
no PowDer®
• Latex,powder-free• Creamcolor• Texturedfinish• TestedforusewithchemotherapydrugsASTMF739• Length:302mm(11.9”)• Fingertipsthickness(single):0.20mm(8mils)
• Latex,sanspoudre• Couleurcrème• Finitexturé• Testépourl’utilisationenchimiothérapieASTMF739• Longueur:302mm(11,9”)• Épaisseur(simple)boutdedoigts:0,20mm(8mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
860260 6 860575 7½
860365 6½ 860680 8
860470 7 860785 8½
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisse
Derma Prene® ulTra• Neoprene,powder-free• Chemicalaccelerator-free• ReducestheriskofTypeIVandIallergies• Greencolor• Smoothfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:308mm(12.1”)• Fingertipsthickness(single):0.20mm(8mils)
• Néoprène,sanspoudre• Sansaccélérateurschimiques• Réduitlesrisquesd’allergiedeTypeIVetI• Couleurverte• Finilisse• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:308mm(12,1”)• Épaisseur(simple)boutdedoigts:0,20mm(8mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
851155 5½ 851575 7½
851260 6 851680 8
851365 6½ 851785 8½
851470 7 851890 9
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisse
Powder-Free examination GlovesInadditiontotheinfectionpreventionbenefitsthatAnsellexamglovesoffer,each glove provides unique features.
Gants d’examen sans poudreChaquegantd’examenAnsellpossèdedescaractéristiquespropres.
mIcro-Touch® aFFInITy®
• Neoprene• ReducestheriskofTypeIallergy• Greencolor• Texturedfingertips• TestedforusewithchemotherapydrugsASTMF739• Length:239mm(9.4”)• Fingertipsthickness(single):0.18mm(7mils)
• Néoprène• Réduitlesrisquesd’allergiedeTypeI• Couleurverte• Boutdesdoigtstexturé• Testépourl’utilisationenchimiothérapieASTMF739• Longueur:239mm(9,4”)• Épaisseur(simple)boutdedoigts:0,18mm(7mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
3770 XS/TP 3773 L/G
3771 S/P 3774 XL/TG
3772 M
100Gloves/DispenserBox–10Boxes/Case 100gants/boîtedistributrice–10boîtes/caisse
mIcro-Touch® nITrIle e.P.®
• Nitrile• ReducestheriskofTypeIallergy• Bluecolor• Texturedfingertips• TestedforusewithchemotherapydrugsASTMD6978• Length:295mm(11.6”)• Fingertipsthickness(single):0.12mm(4.7mils)
• Nitrile• Réduitlesrisquesd’allergiedeTypeI• Couleurbleue• Boutdesdoigtstexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:295mm(11,6”)• Épaisseur(simple)boutdedoigts:0,12mm(4,7mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
6034050 XS/TP 6034053 L/G
6034051 S/P 6034054 XL/TG
6034052 M
100Gloves/DispenserBox–10Boxes/Case 100gants/boîtedistributrice–10boîtes/caisse
mIcro-Touch® nITrIle• Nitrile• ReducestheriskofTypeIallergy• Bluecolor• Texturedfinish• TestedforusewithchemotherapydrugsASTMD6978• Length:239mm(9.4”)• Fingertipsthickness(single):0.12mm(4.7mils)
• Nitrile• Réduitlesrisquesd’allergiedeTypeI• Couleurbleue• Finitexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:239mm(9,4”)• Épaisseur(simple)boutdedoigts:0,12mm(4,7mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
4000 XS/TP 4006 L/G
4002 S/P 4008 XL/TG
4004 M
100Gloves/DispenserBox–10Boxes/Case 100gants/boîtedistributrice–10boîtes/caisse
• Nitrile• ReducestheriskofTypeIallergy• Bluecolor• Texturedfingertips• TestedforusewithchemotherapydrugsASTMD6978• Length:245mm(9.6”)• Fingertipsthickness(single):0.16mm(6.3mils)• CGSBcertified
• Nitrile• Réduitlesrisquesd’allergiedeTypeI• Couleurbleue• Boutdesdoigtstexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:245mm(9,6”)• Épaisseur(simple)boutdedoigts:0,16mm(6,3mil)• Certifiéparl’ONGC
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
6034010 XS/TP 6034013 L/G
6034011 S/P 6034014 XL/TG
6034012 M
100Gloves/DispenserBox–10Boxes/Case 100gants/boîtedistributrice–10boîtes/caisse
mIcro-Touch® nITra-Touch®
mIcro-Touch® nITraTex® STerIleProcedure Gloves• Nitrile• ReducestheriskofTypeIallergy• Bluecolor• Texturedfingertips• TestedforusewithchemotherapydrugsASTMD6978• Length:295mm(11.6”)• Fingertipsthickness(single):0.12mm(4.7mils)
Gants de procédure• Nitrile• Réduitlesrisquesd’allergiedeTypeI• Couleurbleue• Boutdesdoigtstexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:295mm(11,6”)• Épaisseur(simple)boutdedoigts:0,12mm(4,7mil)
Single with Innerwrap / À l’unité avec enveloppe interne
catalog numbers / no de catalogue Sizes / Grandeurs
6034251 S/P
6034252 M
6034253 L/G
6034254 XL/TG
1SterileGlove/Package–100Gloves/DispenserBox–4Boxes/Case/1gantstérile/emballage–100gants/boîtedistributrice–4boîtes/caisse
Pair with Innerwrap / Paire avec enveloppe interne
catalog numbers / no de catalogue Sizes / Grandeurs
6034151 S/P
6034152 M
6034153 L/G
6034154 XL/TG
1SterilePair/Package–50Pairs/DispenserBox–4Boxes/Case1pairestérile/emballage–50paires/boîtedistributrice–4boîtes/caisse
CAUTION:Thisproductcontainsnaturalrubberlatexwhichmaycauseallergicreactions.ATTENTION:Cesproduitscontiennentdulatexdecaoutchoucnaturelpouvantprovoquerdesréactionsallergiques.
mIcro-Touch® e.P.® GloveS• Creamcolor• Handspecific• TestedforusewithchemotherapydrugsASTMF739• Length:305mm(12”)• Fingertipsthickness(single):0.24mm(9.5mils)
• Couleurcrème• Maindroite,maingauche• Testépourl’utilisationenchimiothérapieASTMF739• Longueur:305mm(12”)• Épaisseur(simple)boutdedoigts:0,24mm(9.5mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
920155 XS/TP 920575 M
920365 S/P 920785 L/G
1Pair/Package–25Pairs/DispenserBox,4Boxes/Case 1paire/emballage–25paires/boîtedistributrice,4boîtes/caisse
• Nitrile• Chemicalaccelerator-free*• ReducestheriskofTypeIV(chemical)
andI(latex)allergies• Pinkcolor• Texturedfingertips• TestedforusewithchemotherapydrugsASTMD6978• Length:240mm(9.4”)• Fingertipsthickness(single):0.16mm(6.3mils)
• Nitrile• Sansaccélérateurschimiques*• Réduitlesrisquesd’allergiedeTypeIV(chimique)etI(latex)• Couleurrose• Boutdesdoigtstexturé• Testépourl’utilisationenchimiothérapieASTMD6978• Longueur:240mm(9,4”)• Épaisseur(simple)boutdedoigts:0,16mm(6,3mil)
catalog numbers / no de catalogue Sizes / Grandeurs catalog numbers / no de catalogue Sizes / Grandeurs
6034510 XS/TP 6034513 L/G
6034511 S/P 6034514 XL/TG
6034512 M
100Gloves/DispenserBox–10Boxes/Case 100gants/boîtedistributrice–10boîtes/caisse*Doesnotcontainsulphur-basedacceleratorssuchasthiurams,carbamates,thiazoles,guanidineorthioureas.*Necontientpasd’accélérateursàbasedesulfuretelsquethiurame,carbamate,thiazole,guanidineouthiocarbamide.
mIcro-Touch® nITraFree™
AnsellisproudtopartnerwithSusanG.KomenfortheCure® to unite in the fight against breast cancer.
Ansellestheureuxd’annoncersonpartenariataveclafondationSusanG.KomenfortheCure® dans sa lutte contre le cancer du sein.
latex latex
Synthetic – SynthétiqueSynthetic – Synthétique
clinical references – références cliniques
Graham,J.D.,Green,L.C.,Roberts,M.J.,(1988)InSearchofSafety«ChemicalsandCancerRisk»HarvardUniversityPress,CambridgePress
Office of Occupational Medicine, (January 29, 1986) Guidelines for Handling CDs. OccupationalSafetyandHealthAdministrationActPublication,Pub8-11.
SpecialFeature,(May1990)ASHPTechnicalAssistanceBulletinonHandlingCytotoxicandHazardousDrugs,AmericanJournalofHospitalPharmacy,47,1033-49.
Sotaniemi,E.A.,Sutinen,S.,Arranto,A.J.etal(1983)LiverDamageinNurseshandlingcystostaticagents,ActaMedScand,214,181-9.
Oncology Nursing Society, (1999) Cancer Chemotherapy Guidelines and Recommendations forPractice,2thedition,27.
WorldHealthOrganization,Globalcancerratescouldincreaseby50%to15millionby2020,http://www.who.int/mediacentre/news/releases/2003/pr27/en/retrivedinMarch23,2009from.
Foradditionalinformationandsamples,callAnsellCanadaat1800363-8340
®&TMaretrademarksownedbyAnsellHealthcareProductsLLCoroneofitsaffiliates.©2009AllRightsReserved.
Sivousdésirezrecevoirdeséchantillonsoudeplusamplesrenseignements,appelezAnsellCanadaau800-363-8340.
® & TM sont des marques déposées de Ansell Healthcare Products LLC ou une société affiliée.©2009Tousdroitsréservés.
ansell canada105Lauder,CowansvilleQCJ2K2K8www.ansellcanada.caPrintedinCanada.©2009AllRightsReserved.ImpriméauCanada.©2009Tousdroitsréservés.
ProDucT name ProDucT coDe chemoTheraPy DruGS TeSTeD
latex Powder-Free examination GlovesMicro-Touch®E.P.®Gloves 920155/920785 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Synthetic Powder-Free examination GlovesMicro-Touch®Affinity®-Neoprene 3770/3774 ● ● ● ● ● ● ● ● ●
Micro-Touch®NitraFree™-Nitrile 6034510/6034514 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Micro-Touch®Nitra-Touch®-Nitrile 6034010/6034014 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Micro-Touch®Nitrile 4000/4008 ● ● ● ▲ ● ▲ ● ▲ ● ▲ ● ● ▲ ● ▲ ● ▲ ● ● ● ● ● ● ▲ ● ▲ ●
Micro-Touch®NitrileE.P.® 6034050/6034054 ● ▲ ● ▲ ● ▲ ● ▲ ▲ ▲ ▲ ▲ ▲ ●
Procedure GlovesMicro-Touch®NitraTex®Sterile-Nitrile –EACH
–PAIR
6034251/6034253 6034151/6034153
▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
latex Powder-Free Surgical GlovesEncore® 5785000-1/5785007-1 ▲ ▲ ▲ ▲ ▲ ▲ ▲
EncoreAcclaim® 5795000/5795007 ▲ ▲ ▲ ▲ ▲ ▲ ▲
Encore®Orthopaedic 5788001/5788007 ▲ ▲ ▲ ▲ ▲ ▲ ▲
NoPowder® 860260/860785 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Synthetic Powder-Free Surgical GlovesDermaPrene®IsoTouch®-Polyisoprene 20685255/20685290 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
DermaPrene®Ultra-Neoprene 851155/851890 ● ● ● ▲ ● ● ▲ ● ● ● ▲ ● ▲ ● ▲ ● ● ● ▲ ● ● ● ▲ ● ▲
aSTm TeSTInG: ● F739:Standardtestmethodforresistanceofprotectiveclothingmaterialstopermeationbyliquidsorgasesunderconditionsofcontinuouscontact ▲ D6978:Standardtestmethodforpermeationbychemotherapydrugs
Bleo
myc
inS
ulfa
te
Carb
opla
tin
Carm
ustin
e
Cisp
latin
Cycl
opho
spha
mid
e
Cyta
rabi
ne
Daca
rbaz
ine
Daun
orub
icin
Doxo
rubi
cin
Hy
droc
hlor
ide
Etop
osid
e
5-Fl
uoro
-ura
cile
Idar
ubic
in
Ifosp
ham
ide
Mec
hlor
oeth
amin
e
Mel
phal
an
Met
hrot
rexa
te
Mito
myc
ine
Mito
xant
rone
Pacl
itaxe
l
Thio
tepa
Vinc
ristin
e
cGSBCanadianGeneralStandardsBoarddeliversindependentcertificationprogramswhereproductsareassessedagainstperformanceandqualitystandards.Certificationprogramsareavoluntaryandimpartialmechanismbywhichsupplierscandemonstratethevalueoftheirgoods.
Companynameandqualifiedproductsaredisplayedontheprogramlist on-lineat:pwgsc.gc.ca/cgsb/prgsrv/certprg/program/q020_ind-e.html
onGcOfficedesNormesGénéralesduCanadaoffredesprogrammesindépendantsdecertificationquiévaluentdesproduitsàpartirdenormesderendementetdequalité.Laparticipationauxprogrammesdecertificationestvolontaire;ils’agitd’unsystèmeimpartialpermettantauxfournisseursdedémontrerlavaleurdesproduitsqu’ilsoffrent.
Entrepriseetproduitscertifiéssontaffichéssurlalisteduprogramme enligneau:pwgsc.gc.ca/cgsb/prgsrv/certprg/program/q020_ind-f.html
Tested for use with chemotherapy drugsAnsellchemotherapytestedgloveshavebeentestedeitherbyASTMF739orbyASTMD6978.SpecificchemicalresistancedataareavailableuponrequestbycontactingourCustomerServiceRepresentatives.Glovesusedforprotectionagainstchemotherapydrugsmustbeselectedspecificallyforthetypeofchemicalsused.Reviewmaterialsafetydatasheetsforthechemicalsbeingusedanddeterminetherequiredlevelof protection.
Testé pour la manipulation des médicaments de chimiothérapieLesgantsAnselltestéspourlachimiothérapieontpassélestestsASTMF739ouASTMD6978.Del’informationspécifiquesurlarésistancechimiqueestdisponiblesurdemandeencontactantnosreprésentantsauserviceàlaclientèle.Lesgantsutiliséspourlaprotectioncontrelesproduitscytotoxiquesdoiventêtresélectionnésspécifiquementselonlesproduitschimiquesutilisés.Vérifiezlesfichessignalétiquesdesproduitschimiquesutilisésafindedéterminerleniveaudebarrièredeprotectionrequis.
nom De ProDuIT coDe De ProDuIT mÉDIcamenTS chImIoThÉraPeuTIQueS TeSTÉS
Gants d’examen en latex sans poudreMicro-Touch®E.P.®Gloves 920155/920785 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Gants d’examen synthétiques sans poudreMicro-Touch®Affinity®-Néoprène 3770/3774 ● ● ● ● ● ● ● ● ●
Micro-Touch®NitraFree™-Nitrile 6034510/6034514 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Micro-Touch®Nitra-Touch®-Nitrile 6034010/6034014 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Micro-Touch®Nitrile 4000/4008 ● ● ● ▲ ● ▲ ● ▲ ● ▲ ● ● ▲ ● ▲ ● ▲ ● ● ● ● ● ● ▲ ● ▲ ●
Micro-Touch®NitrileE.P.® 6034050/6034054 ● ▲ ● ▲ ● ▲ ● ▲ ▲ ▲ ▲ ▲ ▲ ●
Gants de Procédure Micro-Touch®NitraTex®Stérile-Nitrile–UNITÉ
–PAIRE
6034251/6034253 6034151/6034153
▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Gants chirurgicaux en latex sans poudreEncore® 5785000-1/5785007-1 ▲ ▲ ▲ ▲ ▲ ▲ ▲
EncoreAcclaim® 5795000/5795007 ▲ ▲ ▲ ▲ ▲ ▲ ▲
Encore®Orthopaedic 5788001/5788007 ▲ ▲ ▲ ▲ ▲ ▲ ▲
NoPowder® 860260/860785 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Gants chirurgicaux synthétiques sans poudreDermaPrene®IsoTouch®-Polyisoprène 20685255/20685290 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
DermaPrene®Ultra-Néoprène 851155/851890 ● ● ● ▲ ● ● ▲ ● ● ● ▲ ● ▲ ● ▲ ● ● ● ▲ ● ● ● ▲ ● ▲
TeST aSTm : ● F739:Standarddespécificationquianalyselarésistanceàlaperméabilitédesmatériauxcontenusdanslesvêtementsdeprotectionaucontactcontinudeliquidesoudegazes ▲ D6978:Standarddespécificationquianalyselaperméabilitéauxproduitscytotoxiques
Sulfa
ted
eBl
eom
ycin
e
Carb
opla
tin
Carm
ustin
Cisp
latin
e
Cycl
opho
spha
mid
e
Cyta
rabi
ne
Daca
rbaz
ine
Daun
orub
icin
e
Hydr
o-ch
lorid
ede
Do
xoru
bici
n
Etop
osid
e
5-Fl
uoro
-ura
cile
Idar
ubic
in
Ifosp
ham
ide
Mec
hlor
oeth
amin
e
Mel
phal
an
Mét
hrot
rexa
te
Mito
myc
ine
Mito
xant
rone
Pacl
itaxe
l
Thio
-Tep
a
Vinc
ristin
e
Gants ansell testés pour l’utilisation en chimiothérapieansell Gloves tested for use with chemotherapy drugs
Safety and Protectionhazardous Drug DangersThehazardsencounteredduringthepreparation,administration,cleanupandgeneralhandlingofanycytotoxicdrughavebeenwelldocumented.Publicconcernismagnifiedbytheperceptionthatcancerrisksareimposeduponworkers,nursesandpharmaciststhat are involved in these procedures.
Thedangersofhandlinghazardousdrugscomefromtheirinherenttoxicityaswellasthetypeofexposurethatmayoccurintheworkplace.Todaythatworkplaceenvironmentmaybeahospitalclinic,otherpatientunit,aphysician’soffice,pharmacy,orinthepatient’shome. Chemotherapy administration has also evolved over the years. Chemotherapyagentsareadministeredviaintravenouspushaswellasacontinuousinfusionthrougha variety of implanted access devices. Exposure, to the healthcare worker or a familymemberinthehome,maybethroughingestionoffoodthatmayhavebeenexposedtothedrug,inhalationofdrugparticlesthatmaybecomeaerosolizedduringpreparation,handlingofpatientexcretaduringhomecare,ordirectskincontactofthedrug.
Studieshavebeenconductedtoassesstheindirectexposureofhealthcareworkers,i.e.nursesandpharmacists,todetermineif therewasanychromosomaldamagetotheseworkersthatpreparedandadministeredthesedrugs.Thisandotherreportspointtotheneedforexcellentexposurecontrolmeasuresandexcellentcompliancetosafehandlingprocedures.
recommendationsSimilar care should be taken in the preparation, administration and disposal ofchemotherapydrugs.Inadditiontohealthcareprofessionals,patientsandpersonsthatare directly involved in home care should also be taught these safety standards andguidelines.
ProtectionDangers des agents toxiquesLes risques encourus durant la préparation, l’administration, le nettoyage et lamanipulationdesagentscytotoxiquessontbiendocumentés.Lepublicest inquietdesrisquesdecanceraccruspourlesprofessionnelsdelasanté,infirmièresetpharmaciensqui pratiquent ces procédures.
Les dangers de la manipulation d’agents cytotoxiques proviennent de la toxicitéintrinsèqueduproduitetde l’expositionquipeutenrésulterdanslemilieudetravail.Aujourd’huilemilieudetravailpeutaussibienêtreunecliniquedel’hôpital,uneunitédesoinsauxpatients,unbureaudemédecin,unepharmacie,oumêmeledomiciledupatient. L’administrationde chimiothérapiea évoluéaucoursdesannées. Lesagentsde chimiothérapie sont administrés par voie topique, percutanée, orale, injectionintraveineusedirecteouperfusioncontinue.L’exposition,desprofessionnelsdelasantéoudesmembresdelafamilledupatient,peutseproduireparl’ingestiondenourriturequiauraitétéencontactaveclesmédicaments,parl’inhalationdeparticulesquiauraientétévaporiséeslorsdelapréparationdumédicament,parlamanipulationd’excrémentsdupatientouparlecontactdirectaveclemédicament.
Desétudesontétéélaboréespourvérifiers’ilyavaitdesdommagesauxchromosomesdestravailleursdelasanté,parexemplelesinfirmièresetlespharmaciens,suiteàl’expositionindirectelorsdelamanipulationoudel’administrationd’agentscytotoxiques.Cesétudesdémontrentlebesoindecontrôleradéquatementl’expositionetl’importancedesuivreunprocessusdemanipulationsécuritairedesagentscytotoxiques.
recommandationsCes recommandations s’appliquent autant à la préparation, qu’à l’administration etl’élimination des médicaments de chimiothérapie. Les professionnels de la santé, lespatientsetlespersonnesdirectementimpliquéesdanslessoinsauxpatientsdevraientconnaîtrecesnormesetrèglesdesécurité.
why Testing for Permeation by chemotherapy drugs?AccordingtotheWorldHealthOrganization,betweennowand2020thecancerrateisgoingtoincreaseby50%toabout15millionnewcasesayear,worldwide.
Thepredictedsharpincreaseinnewcaseswillmainlybeduetotheexistenceofsteadilyageingpopulationsinbothdevelopedanddevelopingcountries,butalsoto thecurrentprevalenceof smokingand the rise innumbersof thoseadoptingunhealthylifestyles.
Oneofthemostfrequentlyusedtreatmentsforcancerischemotherapy.Unfortunatelyitiswellknownthatcytostaticagentsarepotentiallyhazardousforthemanipulator(pharmacist,assistant,nurse,surgeon(HIPECtechnique)etc.).
Cytostaticsareknowntobe:• Mutagenic-induceorincreasegeneticmutationsbycausing changesinDNA• Carcinogenicityinanimalmodels,inpatientpopulation,orboth,• Teratogenicityorfertilityimpairmentinanimalstudiesortreatedpatients.
Someoftheotherpotentialeffectsare:• Decreaseinfertility• Foetalmalformation• Abortion• Extrauterinepregnancy• Hightoxicityforcertainorgans.
• Alwaysweargloveswhenhandlingthedrug - Avoidtouchingthedrug - Washhandsbeforeputtingglovesonandafterwearinggloves.
• Glovesusedforprotectionagainstchemotherapydrugsmustbeselected specificallyforthetypeofchemicalsused.
• Usemedicalgrade,sterileornonsterile,glovesdependingonthetechnique recommendedbyyourhealthcarefacility.
• Alwaysusepowder-freegloves. - Glovepowdersmaycontaminatechemotherapyworkarea.
• Choosealatex,nitrileorneopreneglove - Polyvinylchloride(PVC)glovesarenotrecommendedforhandling chemothapydrugs.
• Usethickglovesthatextendoverthecuffoftheprotectivegown. - Double-glovingisstronglyadvisedwhenthereisariskofexposition duringpreparationoradministrationofchemotherapydrugs. - Ifdouble-gloving,insertfirstgloveunderthecuffandplacethesecond glove over the cuff.
• Beforehandlingchemotherapydrugs, - Observeglovesforanybreakinbarrier.
• Changeglovesaftereachuse,tear,punctureormedicationspillorafter 30minutesofwear.
• Uponremoval,bothglovesneedtobeturnedinsideout - Neverflick,snap,ortossyourgloves.
• Followrecommendationsimplementedbyyourhealthcarefacilityforthe disposal of gloves.
• Toujoursutiliserdesgantspourlamanipulationdesmédicaments dechimiothérapie - Évitertoutcontactdirectavecleproduit - Selaverlesmainsavantetaprèsleportdegants.
• Lesgantsutiliséspourlaprotectioncontrelesproduitscytotoxiquesdoivent êtresélectionnésspécifiquementselonlesproduitschimiquesutilisés.
• Utiliserungantmédicalstérileounonstérileselonlatechnique recommandéeparvotrecentredesanté.
• Toujoursutiliserdesgantssanspoudre. - Lapoudredesgantspeutcontaminerlelieudetravail.
• Choisirungantenlatex,nitrileounéoprène. - Lesgantsenchloruredepolyvinyle(PVC)nesontpasrecommandéspour lamanipulationdemédicamentsdechimiothérapie.
• Porterdesgantsépaisquicouvrentbienlepoignetetlablouse. - Lorsdelapréparationetl’administrationdeproduitscytotoxiques,s’ilya undangerd’exposition,ledoublegantageestderigueur. - Sil’onsuperposelesgants,lapremièrepaireprotègelapeauetla deuxièmepairerecouvrelablouse.
• Avantdemanipulerlesproduitscytotoxiques - Vérifiersilabarrièredeprotectiondesgantsestintacte.
• Changerdegantsaprèschaqueapplication,sicontaminés,déchirés,troués ouàtoutesles30minutesd’utilisation.
• Pourretirerlesgants,tourneràl’enverssanstoucherlasurfacecontaminée - Éviterdelesclaquer,fouetterouremuerinutilement.
• Disposerdesgantsselonlesrecommandationsdevotrecentredesanté.
Pourquoi des tests spécifiques à la perméation des produits cytotoxiques ?L’Organisation mondiale de la Santé prévoit une progression du cancer de 50%d’ici2020,soitenviron15millionsdenouveauxcasdecancersparanàl’échellemondiale.
Lacausedecetteaugmentationprévuerésideprincipalementdanslevieillissementdes populations, tant dans les pays développés que dans les pays en voie dedéveloppement. La croissance du tabagisme ainsi que la généralisation demauvaiseshabitudesdevienesontpasétrangèresàlamultiplicationdescasdecancers.
La chimiothérapie figure parmi les traitements les plus fréquemment utiliséspour combattre le cancer. Or, on sait que les cytostatiques sont potentiellementdangereuxpourceluiquilesmanipule(pharmacien,assistant,infirmière,chirurgien[techniqueCHIP]etc.).
Lescytostatiquessontréputés:• mutagènes(ex.:provoquentouaugmententlesmutationsgénétiquesen changeantl’ADN)• carcinogènespourcertainsanimauxdelaboratoire,pourlespatients oulesdeux• tératogènesouproblèmesdefertilitésurlesanimauxétudiésou sur les patients traités.
Ilspeuventégalementprovoquerleseffetssecondairessuivants:• diminutiondelafécondité• malformationsfœtales• avortements• grossessesextrautérines• hautrisqued’intoxicationdecertainsorganes.
Glove characteristicsCaractéristiques du gant
Cytostatic characteristicsCaractéristiques du cytostatique
Room parameters Paramètres ambiants
Permeation rateTaux de perméation
WorkerTravailleur
OtherAutres
Exposure time Durée d’exposition
Permeationdependsonmanyparametersandthereforetheresultsobtainedcannotbeextendedtoanyothermaterial,brandorcompetitiveproduct.
Letempsdeperméationdépenddeplusieursparamètres.Lesrésultatsobtenusnepeuventêtreextrapolésàaucuneautrematière,marqueouproduitconcurrent.
Permeation : a very complex processla perméation : un processus très complexe
• Revolutionaryanti-slipcuffadherestoalltypesofgowns• Eliminatescuffroll-down
• Bandeadhésiveauxpoignetsquipermetauxgantsdetenirbienen placesurtouslestypesdeblouseschirurgicales• Élimineleproblèmed’enroulement
assurance qualité ansellansell Quality assurance
clinical references – références cliniques
Graham,J.D.,Green,L.C.,Roberts,M.J.,(1988)InSearchofSafety«ChemicalsandCancerRisk»HarvardUniversityPress,CambridgePress
Office of Occupational Medicine, (January 29, 1986) Guidelines for Handling CDs. OccupationalSafetyandHealthAdministrationActPublication,Pub8-11.
SpecialFeature,(May1990)ASHPTechnicalAssistanceBulletinonHandlingCytotoxicandHazardousDrugs,AmericanJournalofHospitalPharmacy,47,1033-49.
Sotaniemi,E.A.,Sutinen,S.,Arranto,A.J.etal(1983)LiverDamageinNurseshandlingcystostaticagents,ActaMedScand,214,181-9.
Oncology Nursing Society, (1999) Cancer Chemotherapy Guidelines and Recommendations forPractice,2thedition,27.
WorldHealthOrganization,Globalcancerratescouldincreaseby50%to15millionby2020,http://www.who.int/mediacentre/news/releases/2003/pr27/en/retrivedinMarch23,2009from.
Foradditionalinformationandsamples,callAnsellCanadaat1800363-8340
®&TMaretrademarksownedbyAnsellHealthcareProductsLLCoroneofitsaffiliates.©2009AllRightsReserved.
Sivousdésirezrecevoirdeséchantillonsoudeplusamplesrenseignements,appelezAnsellCanadaau800-363-8340.
® & TM sont des marques déposées de Ansell Healthcare Products LLC ou une société affiliée.©2009Tousdroitsréservés.
ansell canada105Lauder,CowansvilleQCJ2K2K8www.ansellcanada.caPrintedinCanada.©2009AllRightsReserved.ImpriméauCanada.©2009Tousdroitsréservés.
ProDucT name ProDucT coDe chemoTheraPy DruGS TeSTeD
latex Powder-Free examination GlovesMicro-Touch®E.P.®Gloves 920155/920785 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Synthetic Powder-Free examination GlovesMicro-Touch®Affinity®-Neoprene 3770/3774 ● ● ● ● ● ● ● ● ●
Micro-Touch®NitraFree™-Nitrile 6034510/6034514 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Micro-Touch®Nitra-Touch®-Nitrile 6034010/6034014 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Micro-Touch®Nitrile 4000/4008 ● ● ● ▲ ● ▲ ● ▲ ● ▲ ● ● ▲ ● ▲ ● ▲ ● ● ● ● ● ● ▲ ● ▲ ●
Micro-Touch®NitrileE.P.® 6034050/6034054 ● ▲ ● ▲ ● ▲ ● ▲ ▲ ▲ ▲ ▲ ▲ ●
Procedure GlovesMicro-Touch®NitraTex®Sterile-Nitrile –EACH
–PAIR
6034251/6034253 6034151/6034153
▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
latex Powder-Free Surgical GlovesEncore® 5785000-1/5785007-1 ▲ ▲ ▲ ▲ ▲ ▲ ▲
EncoreAcclaim® 5795000/5795007 ▲ ▲ ▲ ▲ ▲ ▲ ▲
Encore®Orthopaedic 5788001/5788007 ▲ ▲ ▲ ▲ ▲ ▲ ▲
NoPowder® 860260/860785 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Synthetic Powder-Free Surgical GlovesDermaPrene®IsoTouch®-Polyisoprene 20685255/20685290 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
DermaPrene®Ultra-Neoprene 851155/851890 ● ● ● ▲ ● ● ▲ ● ● ● ▲ ● ▲ ● ▲ ● ● ● ▲ ● ● ● ▲ ● ▲
aSTm TeSTInG: ● F739:Standardtestmethodforresistanceofprotectiveclothingmaterialstopermeationbyliquidsorgasesunderconditionsofcontinuouscontact ▲ D6978:Standardtestmethodforpermeationbychemotherapydrugs
Bleo
myc
inS
ulfa
te
Carb
opla
tin
Carm
ustin
e
Cisp
latin
Cycl
opho
spha
mid
e
Cyta
rabi
ne
Daca
rbaz
ine
Daun
orub
icin
Doxo
rubi
cin
Hy
droc
hlor
ide
Etop
osid
e
5-Fl
uoro
-ura
cile
Idar
ubic
in
Ifosp
ham
ide
Mec
hlor
oeth
amin
e
Mel
phal
an
Met
hrot
rexa
te
Mito
myc
ine
Mito
xant
rone
Pacl
itaxe
l
Thio
tepa
Vinc
ristin
e
cGSBCanadianGeneralStandardsBoarddeliversindependentcertificationprogramswhereproductsareassessedagainstperformanceandqualitystandards.Certificationprogramsareavoluntaryandimpartialmechanismbywhichsupplierscandemonstratethevalueoftheirgoods.
Companynameandqualifiedproductsaredisplayedontheprogramlist on-lineat:pwgsc.gc.ca/cgsb/prgsrv/certprg/program/q020_ind-e.html
onGcOfficedesNormesGénéralesduCanadaoffredesprogrammesindépendantsdecertificationquiévaluentdesproduitsàpartirdenormesderendementetdequalité.Laparticipationauxprogrammesdecertificationestvolontaire;ils’agitd’unsystèmeimpartialpermettantauxfournisseursdedémontrerlavaleurdesproduitsqu’ilsoffrent.
Entrepriseetproduitscertifiéssontaffichéssurlalisteduprogramme enligneau:pwgsc.gc.ca/cgsb/prgsrv/certprg/program/q020_ind-f.html
Tested for use with chemotherapy drugsAnsellchemotherapytestedgloveshavebeentestedeitherbyASTMF739orbyASTMD6978.SpecificchemicalresistancedataareavailableuponrequestbycontactingourCustomerServiceRepresentatives.Glovesusedforprotectionagainstchemotherapydrugsmustbeselectedspecificallyforthetypeofchemicalsused.Reviewmaterialsafetydatasheetsforthechemicalsbeingusedanddeterminetherequiredlevelof protection.
Testé pour la manipulation des médicaments de chimiothérapieLesgantsAnselltestéspourlachimiothérapieontpassélestestsASTMF739ouASTMD6978.Del’informationspécifiquesurlarésistancechimiqueestdisponiblesurdemandeencontactantnosreprésentantsauserviceàlaclientèle.Lesgantsutiliséspourlaprotectioncontrelesproduitscytotoxiquesdoiventêtresélectionnésspécifiquementselonlesproduitschimiquesutilisés.Vérifiezlesfichessignalétiquesdesproduitschimiquesutilisésafindedéterminerleniveaudebarrièredeprotectionrequis.
nom De ProDuIT coDe De ProDuIT mÉDIcamenTS chImIoThÉraPeuTIQueS TeSTÉS
Gants d’examen en latex sans poudreMicro-Touch®E.P.®Gloves 920155/920785 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Gants d’examen synthétiques sans poudreMicro-Touch®Affinity®-Néoprène 3770/3774 ● ● ● ● ● ● ● ● ●
Micro-Touch®NitraFree™-Nitrile 6034510/6034514 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Micro-Touch®Nitra-Touch®-Nitrile 6034010/6034014 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Micro-Touch®Nitrile 4000/4008 ● ● ● ▲ ● ▲ ● ▲ ● ▲ ● ● ▲ ● ▲ ● ▲ ● ● ● ● ● ● ▲ ● ▲ ●
Micro-Touch®NitrileE.P.® 6034050/6034054 ● ▲ ● ▲ ● ▲ ● ▲ ▲ ▲ ▲ ▲ ▲ ●
Gants de Procédure Micro-Touch®NitraTex®Stérile-Nitrile–UNITÉ
–PAIRE
6034251/6034253 6034151/6034153
▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Gants chirurgicaux en latex sans poudreEncore® 5785000-1/5785007-1 ▲ ▲ ▲ ▲ ▲ ▲ ▲
EncoreAcclaim® 5795000/5795007 ▲ ▲ ▲ ▲ ▲ ▲ ▲
Encore®Orthopaedic 5788001/5788007 ▲ ▲ ▲ ▲ ▲ ▲ ▲
NoPowder® 860260/860785 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Gants chirurgicaux synthétiques sans poudreDermaPrene®IsoTouch®-Polyisoprène 20685255/20685290 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
DermaPrene®Ultra-Néoprène 851155/851890 ● ● ● ▲ ● ● ▲ ● ● ● ▲ ● ▲ ● ▲ ● ● ● ▲ ● ● ● ▲ ● ▲
TeST aSTm : ● F739:Standarddespécificationquianalyselarésistanceàlaperméabilitédesmatériauxcontenusdanslesvêtementsdeprotectionaucontactcontinudeliquidesoudegazes ▲ D6978:Standarddespécificationquianalyselaperméabilitéauxproduitscytotoxiques
Sulfa
ted
eBl
eom
ycin
e
Carb
opla
tin
Carm
ustin
Cisp
latin
e
Cycl
opho
spha
mid
e
Cyta
rabi
ne
Daca
rbaz
ine
Daun
orub
icin
e
Hydr
o-ch
lorid
ede
Do
xoru
bici
n
Etop
osid
e
5-Fl
uoro
-ura
cile
Idar
ubic
in
Ifosp
ham
ide
Mec
hlor
oeth
amin
e
Mel
phal
an
Mét
hrot
rexa
te
Mito
myc
ine
Mito
xant
rone
Pacl
itaxe
l
Thio
-Tep
a
Vinc
ristin
e
Gants ansell testés pour l’utilisation en chimiothérapieansell Gloves tested for use with chemotherapy drugs
Safety and Protectionhazardous Drug DangersThehazardsencounteredduringthepreparation,administration,cleanupandgeneralhandlingofanycytotoxicdrughavebeenwelldocumented.Publicconcernismagnifiedbytheperceptionthatcancerrisksareimposeduponworkers,nursesandpharmaciststhat are involved in these procedures.
Thedangersofhandlinghazardousdrugscomefromtheirinherenttoxicityaswellasthetypeofexposurethatmayoccurintheworkplace.Todaythatworkplaceenvironmentmaybeahospitalclinic,otherpatientunit,aphysician’soffice,pharmacy,orinthepatient’shome. Chemotherapy administration has also evolved over the years. Chemotherapyagentsareadministeredviaintravenouspushaswellasacontinuousinfusionthrougha variety of implanted access devices. Exposure, to the healthcare worker or a familymemberinthehome,maybethroughingestionoffoodthatmayhavebeenexposedtothedrug,inhalationofdrugparticlesthatmaybecomeaerosolizedduringpreparation,handlingofpatientexcretaduringhomecare,ordirectskincontactofthedrug.
Studieshavebeenconductedtoassesstheindirectexposureofhealthcareworkers,i.e.nursesandpharmacists,todetermineif therewasanychromosomaldamagetotheseworkersthatpreparedandadministeredthesedrugs.Thisandotherreportspointtotheneedforexcellentexposurecontrolmeasuresandexcellentcompliancetosafehandlingprocedures.
recommendationsSimilar care should be taken in the preparation, administration and disposal ofchemotherapydrugs.Inadditiontohealthcareprofessionals,patientsandpersonsthatare directly involved in home care should also be taught these safety standards andguidelines.
ProtectionDangers des agents toxiquesLes risques encourus durant la préparation, l’administration, le nettoyage et lamanipulationdesagentscytotoxiquessontbiendocumentés.Lepublicest inquietdesrisquesdecanceraccruspourlesprofessionnelsdelasanté,infirmièresetpharmaciensqui pratiquent ces procédures.
Les dangers de la manipulation d’agents cytotoxiques proviennent de la toxicitéintrinsèqueduproduitetde l’expositionquipeutenrésulterdanslemilieudetravail.Aujourd’huilemilieudetravailpeutaussibienêtreunecliniquedel’hôpital,uneunitédesoinsauxpatients,unbureaudemédecin,unepharmacie,oumêmeledomiciledupatient. L’administrationde chimiothérapiea évoluéaucoursdesannées. Lesagentsde chimiothérapie sont administrés par voie topique, percutanée, orale, injectionintraveineusedirecteouperfusioncontinue.L’exposition,desprofessionnelsdelasantéoudesmembresdelafamilledupatient,peutseproduireparl’ingestiondenourriturequiauraitétéencontactaveclesmédicaments,parl’inhalationdeparticulesquiauraientétévaporiséeslorsdelapréparationdumédicament,parlamanipulationd’excrémentsdupatientouparlecontactdirectaveclemédicament.
Desétudesontétéélaboréespourvérifiers’ilyavaitdesdommagesauxchromosomesdestravailleursdelasanté,parexemplelesinfirmièresetlespharmaciens,suiteàl’expositionindirectelorsdelamanipulationoudel’administrationd’agentscytotoxiques.Cesétudesdémontrentlebesoindecontrôleradéquatementl’expositionetl’importancedesuivreunprocessusdemanipulationsécuritairedesagentscytotoxiques.
recommandationsCes recommandations s’appliquent autant à la préparation, qu’à l’administration etl’élimination des médicaments de chimiothérapie. Les professionnels de la santé, lespatientsetlespersonnesdirectementimpliquéesdanslessoinsauxpatientsdevraientconnaîtrecesnormesetrèglesdesécurité.
why Testing for Permeation by chemotherapy drugs?AccordingtotheWorldHealthOrganization,betweennowand2020thecancerrateisgoingtoincreaseby50%toabout15millionnewcasesayear,worldwide.
Thepredictedsharpincreaseinnewcaseswillmainlybeduetotheexistenceofsteadilyageingpopulationsinbothdevelopedanddevelopingcountries,butalsoto thecurrentprevalenceof smokingand the rise innumbersof thoseadoptingunhealthylifestyles.
Oneofthemostfrequentlyusedtreatmentsforcancerischemotherapy.Unfortunatelyitiswellknownthatcytostaticagentsarepotentiallyhazardousforthemanipulator(pharmacist,assistant,nurse,surgeon(HIPECtechnique)etc.).
Cytostaticsareknowntobe:• Mutagenic-induceorincreasegeneticmutationsbycausing changesinDNA• Carcinogenicityinanimalmodels,inpatientpopulation,orboth,• Teratogenicityorfertilityimpairmentinanimalstudiesortreatedpatients.
Someoftheotherpotentialeffectsare:• Decreaseinfertility• Foetalmalformation• Abortion• Extrauterinepregnancy• Hightoxicityforcertainorgans.
• Alwaysweargloveswhenhandlingthedrug - Avoidtouchingthedrug - Washhandsbeforeputtingglovesonandafterwearinggloves.
• Glovesusedforprotectionagainstchemotherapydrugsmustbeselected specificallyforthetypeofchemicalsused.
• Usemedicalgrade,sterileornonsterile,glovesdependingonthetechnique recommendedbyyourhealthcarefacility.
• Alwaysusepowder-freegloves. - Glovepowdersmaycontaminatechemotherapyworkarea.
• Choosealatex,nitrileorneopreneglove - Polyvinylchloride(PVC)glovesarenotrecommendedforhandling chemothapydrugs.
• Usethickglovesthatextendoverthecuffoftheprotectivegown. - Double-glovingisstronglyadvisedwhenthereisariskofexposition duringpreparationoradministrationofchemotherapydrugs. - Ifdouble-gloving,insertfirstgloveunderthecuffandplacethesecond glove over the cuff.
• Beforehandlingchemotherapydrugs, - Observeglovesforanybreakinbarrier.
• Changeglovesaftereachuse,tear,punctureormedicationspillorafter 30minutesofwear.
• Uponremoval,bothglovesneedtobeturnedinsideout - Neverflick,snap,ortossyourgloves.
• Followrecommendationsimplementedbyyourhealthcarefacilityforthe disposal of gloves.
• Toujoursutiliserdesgantspourlamanipulationdesmédicaments dechimiothérapie - Évitertoutcontactdirectavecleproduit - Selaverlesmainsavantetaprèsleportdegants.
• Lesgantsutiliséspourlaprotectioncontrelesproduitscytotoxiquesdoivent êtresélectionnésspécifiquementselonlesproduitschimiquesutilisés.
• Utiliserungantmédicalstérileounonstérileselonlatechnique recommandéeparvotrecentredesanté.
• Toujoursutiliserdesgantssanspoudre. - Lapoudredesgantspeutcontaminerlelieudetravail.
• Choisirungantenlatex,nitrileounéoprène. - Lesgantsenchloruredepolyvinyle(PVC)nesontpasrecommandéspour lamanipulationdemédicamentsdechimiothérapie.
• Porterdesgantsépaisquicouvrentbienlepoignetetlablouse. - Lorsdelapréparationetl’administrationdeproduitscytotoxiques,s’ilya undangerd’exposition,ledoublegantageestderigueur. - Sil’onsuperposelesgants,lapremièrepaireprotègelapeauetla deuxièmepairerecouvrelablouse.
• Avantdemanipulerlesproduitscytotoxiques - Vérifiersilabarrièredeprotectiondesgantsestintacte.
• Changerdegantsaprèschaqueapplication,sicontaminés,déchirés,troués ouàtoutesles30minutesd’utilisation.
• Pourretirerlesgants,tourneràl’enverssanstoucherlasurfacecontaminée - Éviterdelesclaquer,fouetterouremuerinutilement.
• Disposerdesgantsselonlesrecommandationsdevotrecentredesanté.
Pourquoi des tests spécifiques à la perméation des produits cytotoxiques ?L’Organisation mondiale de la Santé prévoit une progression du cancer de 50%d’ici2020,soitenviron15millionsdenouveauxcasdecancersparanàl’échellemondiale.
Lacausedecetteaugmentationprévuerésideprincipalementdanslevieillissementdes populations, tant dans les pays développés que dans les pays en voie dedéveloppement. La croissance du tabagisme ainsi que la généralisation demauvaiseshabitudesdevienesontpasétrangèresàlamultiplicationdescasdecancers.
La chimiothérapie figure parmi les traitements les plus fréquemment utiliséspour combattre le cancer. Or, on sait que les cytostatiques sont potentiellementdangereuxpourceluiquilesmanipule(pharmacien,assistant,infirmière,chirurgien[techniqueCHIP]etc.).
Lescytostatiquessontréputés:• mutagènes(ex.:provoquentouaugmententlesmutationsgénétiquesen changeantl’ADN)• carcinogènespourcertainsanimauxdelaboratoire,pourlespatients oulesdeux• tératogènesouproblèmesdefertilitésurlesanimauxétudiésou sur les patients traités.
Ilspeuventégalementprovoquerleseffetssecondairessuivants:• diminutiondelafécondité• malformationsfœtales• avortements• grossessesextrautérines• hautrisqued’intoxicationdecertainsorganes.
Glove characteristicsCaractéristiques du gant
Cytostatic characteristicsCaractéristiques du cytostatique
Room parameters Paramètres ambiants
Permeation rateTaux de perméation
WorkerTravailleur
OtherAutres
Exposure time Durée d’exposition
Permeationdependsonmanyparametersandthereforetheresultsobtainedcannotbeextendedtoanyothermaterial,brandorcompetitiveproduct.
Letempsdeperméationdépenddeplusieursparamètres.Lesrésultatsobtenusnepeuventêtreextrapolésàaucuneautrematière,marqueouproduitconcurrent.
Permeation : a very complex processla perméation : un processus très complexe
• Revolutionaryanti-slipcuffadherestoalltypesofgowns• Eliminatescuffroll-down
• Bandeadhésiveauxpoignetsquipermetauxgantsdetenirbienen placesurtouslestypesdeblouseschirurgicales• Élimineleproblèmed’enroulement
assurance qualité ansellansell Quality assurance
clinical references – références cliniques
Graham,J.D.,Green,L.C.,Roberts,M.J.,(1988)InSearchofSafety«ChemicalsandCancerRisk»HarvardUniversityPress,CambridgePress
Office of Occupational Medicine, (January 29, 1986) Guidelines for Handling CDs. OccupationalSafetyandHealthAdministrationActPublication,Pub8-11.
SpecialFeature,(May1990)ASHPTechnicalAssistanceBulletinonHandlingCytotoxicandHazardousDrugs,AmericanJournalofHospitalPharmacy,47,1033-49.
Sotaniemi,E.A.,Sutinen,S.,Arranto,A.J.etal(1983)LiverDamageinNurseshandlingcystostaticagents,ActaMedScand,214,181-9.
Oncology Nursing Society, (1999) Cancer Chemotherapy Guidelines and Recommendations forPractice,2thedition,27.
WorldHealthOrganization,Globalcancerratescouldincreaseby50%to15millionby2020,http://www.who.int/mediacentre/news/releases/2003/pr27/en/retrivedinMarch23,2009from.
Foradditionalinformationandsamples,callAnsellCanadaat1800363-8340
®&TMaretrademarksownedbyAnsellHealthcareProductsLLCoroneofitsaffiliates.©2009AllRightsReserved.
Sivousdésirezrecevoirdeséchantillonsoudeplusamplesrenseignements,appelezAnsellCanadaau800-363-8340.
® & TM sont des marques déposées de Ansell Healthcare Products LLC ou une société affiliée.©2009Tousdroitsréservés.
ansell canada105Lauder,CowansvilleQCJ2K2K8www.ansellcanada.caPrintedinCanada.©2009AllRightsReserved.ImpriméauCanada.©2009Tousdroitsréservés.
ProDucT name ProDucT coDe chemoTheraPy DruGS TeSTeD
latex Powder-Free examination GlovesMicro-Touch®E.P.®Gloves 920155/920785 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Synthetic Powder-Free examination GlovesMicro-Touch®Affinity®-Neoprene 3770/3774 ● ● ● ● ● ● ● ● ●
Micro-Touch®NitraFree™-Nitrile 6034510/6034514 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Micro-Touch®Nitra-Touch®-Nitrile 6034010/6034014 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Micro-Touch®Nitrile 4000/4008 ● ● ● ▲ ● ▲ ● ▲ ● ▲ ● ● ▲ ● ▲ ● ▲ ● ● ● ● ● ● ▲ ● ▲ ●
Micro-Touch®NitrileE.P.® 6034050/6034054 ● ▲ ● ▲ ● ▲ ● ▲ ▲ ▲ ▲ ▲ ▲ ●
Procedure GlovesMicro-Touch®NitraTex®Sterile-Nitrile –EACH
–PAIR
6034251/6034253 6034151/6034153
▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
latex Powder-Free Surgical GlovesEncore® 5785000-1/5785007-1 ▲ ▲ ▲ ▲ ▲ ▲ ▲
EncoreAcclaim® 5795000/5795007 ▲ ▲ ▲ ▲ ▲ ▲ ▲
Encore®Orthopaedic 5788001/5788007 ▲ ▲ ▲ ▲ ▲ ▲ ▲
NoPowder® 860260/860785 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Synthetic Powder-Free Surgical GlovesDermaPrene®IsoTouch®-Polyisoprene 20685255/20685290 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
DermaPrene®Ultra-Neoprene 851155/851890 ● ● ● ▲ ● ● ▲ ● ● ● ▲ ● ▲ ● ▲ ● ● ● ▲ ● ● ● ▲ ● ▲
aSTm TeSTInG: ● F739:Standardtestmethodforresistanceofprotectiveclothingmaterialstopermeationbyliquidsorgasesunderconditionsofcontinuouscontact ▲ D6978:Standardtestmethodforpermeationbychemotherapydrugs
Bleo
myc
inS
ulfa
te
Carb
opla
tin
Carm
ustin
e
Cisp
latin
Cycl
opho
spha
mid
e
Cyta
rabi
ne
Daca
rbaz
ine
Daun
orub
icin
Doxo
rubi
cin
Hy
droc
hlor
ide
Etop
osid
e
5-Fl
uoro
-ura
cile
Idar
ubic
in
Ifosp
ham
ide
Mec
hlor
oeth
amin
e
Mel
phal
an
Met
hrot
rexa
te
Mito
myc
ine
Mito
xant
rone
Pacl
itaxe
l
Thio
tepa
Vinc
ristin
e
cGSBCanadianGeneralStandardsBoarddeliversindependentcertificationprogramswhereproductsareassessedagainstperformanceandqualitystandards.Certificationprogramsareavoluntaryandimpartialmechanismbywhichsupplierscandemonstratethevalueoftheirgoods.
Companynameandqualifiedproductsaredisplayedontheprogramlist on-lineat:pwgsc.gc.ca/cgsb/prgsrv/certprg/program/q020_ind-e.html
onGcOfficedesNormesGénéralesduCanadaoffredesprogrammesindépendantsdecertificationquiévaluentdesproduitsàpartirdenormesderendementetdequalité.Laparticipationauxprogrammesdecertificationestvolontaire;ils’agitd’unsystèmeimpartialpermettantauxfournisseursdedémontrerlavaleurdesproduitsqu’ilsoffrent.
Entrepriseetproduitscertifiéssontaffichéssurlalisteduprogramme enligneau:pwgsc.gc.ca/cgsb/prgsrv/certprg/program/q020_ind-f.html
Tested for use with chemotherapy drugsAnsellchemotherapytestedgloveshavebeentestedeitherbyASTMF739orbyASTMD6978.SpecificchemicalresistancedataareavailableuponrequestbycontactingourCustomerServiceRepresentatives.Glovesusedforprotectionagainstchemotherapydrugsmustbeselectedspecificallyforthetypeofchemicalsused.Reviewmaterialsafetydatasheetsforthechemicalsbeingusedanddeterminetherequiredlevelof protection.
Testé pour la manipulation des médicaments de chimiothérapieLesgantsAnselltestéspourlachimiothérapieontpassélestestsASTMF739ouASTMD6978.Del’informationspécifiquesurlarésistancechimiqueestdisponiblesurdemandeencontactantnosreprésentantsauserviceàlaclientèle.Lesgantsutiliséspourlaprotectioncontrelesproduitscytotoxiquesdoiventêtresélectionnésspécifiquementselonlesproduitschimiquesutilisés.Vérifiezlesfichessignalétiquesdesproduitschimiquesutilisésafindedéterminerleniveaudebarrièredeprotectionrequis.
nom De ProDuIT coDe De ProDuIT mÉDIcamenTS chImIoThÉraPeuTIQueS TeSTÉS
Gants d’examen en latex sans poudreMicro-Touch®E.P.®Gloves 920155/920785 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Gants d’examen synthétiques sans poudreMicro-Touch®Affinity®-Néoprène 3770/3774 ● ● ● ● ● ● ● ● ●
Micro-Touch®NitraFree™-Nitrile 6034510/6034514 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Micro-Touch®Nitra-Touch®-Nitrile 6034010/6034014 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Micro-Touch®Nitrile 4000/4008 ● ● ● ▲ ● ▲ ● ▲ ● ▲ ● ● ▲ ● ▲ ● ▲ ● ● ● ● ● ● ▲ ● ▲ ●
Micro-Touch®NitrileE.P.® 6034050/6034054 ● ▲ ● ▲ ● ▲ ● ▲ ▲ ▲ ▲ ▲ ▲ ●
Gants de Procédure Micro-Touch®NitraTex®Stérile-Nitrile–UNITÉ
–PAIRE
6034251/6034253 6034151/6034153
▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Gants chirurgicaux en latex sans poudreEncore® 5785000-1/5785007-1 ▲ ▲ ▲ ▲ ▲ ▲ ▲
EncoreAcclaim® 5795000/5795007 ▲ ▲ ▲ ▲ ▲ ▲ ▲
Encore®Orthopaedic 5788001/5788007 ▲ ▲ ▲ ▲ ▲ ▲ ▲
NoPowder® 860260/860785 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Gants chirurgicaux synthétiques sans poudreDermaPrene®IsoTouch®-Polyisoprène 20685255/20685290 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
DermaPrene®Ultra-Néoprène 851155/851890 ● ● ● ▲ ● ● ▲ ● ● ● ▲ ● ▲ ● ▲ ● ● ● ▲ ● ● ● ▲ ● ▲
TeST aSTm : ● F739:Standarddespécificationquianalyselarésistanceàlaperméabilitédesmatériauxcontenusdanslesvêtementsdeprotectionaucontactcontinudeliquidesoudegazes ▲ D6978:Standarddespécificationquianalyselaperméabilitéauxproduitscytotoxiques
Sulfa
ted
eBl
eom
ycin
e
Carb
opla
tin
Carm
ustin
Cisp
latin
e
Cycl
opho
spha
mid
e
Cyta
rabi
ne
Daca
rbaz
ine
Daun
orub
icin
e
Hydr
o-ch
lorid
ede
Do
xoru
bici
n
Etop
osid
e
5-Fl
uoro
-ura
cile
Idar
ubic
in
Ifosp
ham
ide
Mec
hlor
oeth
amin
e
Mel
phal
an
Mét
hrot
rexa
te
Mito
myc
ine
Mito
xant
rone
Pacl
itaxe
l
Thio
-Tep
a
Vinc
ristin
e
Gants ansell testés pour l’utilisation en chimiothérapieansell Gloves tested for use with chemotherapy drugs
Safety and Protectionhazardous Drug DangersThehazardsencounteredduringthepreparation,administration,cleanupandgeneralhandlingofanycytotoxicdrughavebeenwelldocumented.Publicconcernismagnifiedbytheperceptionthatcancerrisksareimposeduponworkers,nursesandpharmaciststhat are involved in these procedures.
Thedangersofhandlinghazardousdrugscomefromtheirinherenttoxicityaswellasthetypeofexposurethatmayoccurintheworkplace.Todaythatworkplaceenvironmentmaybeahospitalclinic,otherpatientunit,aphysician’soffice,pharmacy,orinthepatient’shome. Chemotherapy administration has also evolved over the years. Chemotherapyagentsareadministeredviaintravenouspushaswellasacontinuousinfusionthrougha variety of implanted access devices. Exposure, to the healthcare worker or a familymemberinthehome,maybethroughingestionoffoodthatmayhavebeenexposedtothedrug,inhalationofdrugparticlesthatmaybecomeaerosolizedduringpreparation,handlingofpatientexcretaduringhomecare,ordirectskincontactofthedrug.
Studieshavebeenconductedtoassesstheindirectexposureofhealthcareworkers,i.e.nursesandpharmacists,todetermineif therewasanychromosomaldamagetotheseworkersthatpreparedandadministeredthesedrugs.Thisandotherreportspointtotheneedforexcellentexposurecontrolmeasuresandexcellentcompliancetosafehandlingprocedures.
recommendationsSimilar care should be taken in the preparation, administration and disposal ofchemotherapydrugs.Inadditiontohealthcareprofessionals,patientsandpersonsthatare directly involved in home care should also be taught these safety standards andguidelines.
ProtectionDangers des agents toxiquesLes risques encourus durant la préparation, l’administration, le nettoyage et lamanipulationdesagentscytotoxiquessontbiendocumentés.Lepublicest inquietdesrisquesdecanceraccruspourlesprofessionnelsdelasanté,infirmièresetpharmaciensqui pratiquent ces procédures.
Les dangers de la manipulation d’agents cytotoxiques proviennent de la toxicitéintrinsèqueduproduitetde l’expositionquipeutenrésulterdanslemilieudetravail.Aujourd’huilemilieudetravailpeutaussibienêtreunecliniquedel’hôpital,uneunitédesoinsauxpatients,unbureaudemédecin,unepharmacie,oumêmeledomiciledupatient. L’administrationde chimiothérapiea évoluéaucoursdesannées. Lesagentsde chimiothérapie sont administrés par voie topique, percutanée, orale, injectionintraveineusedirecteouperfusioncontinue.L’exposition,desprofessionnelsdelasantéoudesmembresdelafamilledupatient,peutseproduireparl’ingestiondenourriturequiauraitétéencontactaveclesmédicaments,parl’inhalationdeparticulesquiauraientétévaporiséeslorsdelapréparationdumédicament,parlamanipulationd’excrémentsdupatientouparlecontactdirectaveclemédicament.
Desétudesontétéélaboréespourvérifiers’ilyavaitdesdommagesauxchromosomesdestravailleursdelasanté,parexemplelesinfirmièresetlespharmaciens,suiteàl’expositionindirectelorsdelamanipulationoudel’administrationd’agentscytotoxiques.Cesétudesdémontrentlebesoindecontrôleradéquatementl’expositionetl’importancedesuivreunprocessusdemanipulationsécuritairedesagentscytotoxiques.
recommandationsCes recommandations s’appliquent autant à la préparation, qu’à l’administration etl’élimination des médicaments de chimiothérapie. Les professionnels de la santé, lespatientsetlespersonnesdirectementimpliquéesdanslessoinsauxpatientsdevraientconnaîtrecesnormesetrèglesdesécurité.
why Testing for Permeation by chemotherapy drugs?AccordingtotheWorldHealthOrganization,betweennowand2020thecancerrateisgoingtoincreaseby50%toabout15millionnewcasesayear,worldwide.
Thepredictedsharpincreaseinnewcaseswillmainlybeduetotheexistenceofsteadilyageingpopulationsinbothdevelopedanddevelopingcountries,butalsoto thecurrentprevalenceof smokingand the rise innumbersof thoseadoptingunhealthylifestyles.
Oneofthemostfrequentlyusedtreatmentsforcancerischemotherapy.Unfortunatelyitiswellknownthatcytostaticagentsarepotentiallyhazardousforthemanipulator(pharmacist,assistant,nurse,surgeon(HIPECtechnique)etc.).
Cytostaticsareknowntobe:• Mutagenic-induceorincreasegeneticmutationsbycausing changesinDNA• Carcinogenicityinanimalmodels,inpatientpopulation,orboth,• Teratogenicityorfertilityimpairmentinanimalstudiesortreatedpatients.
Someoftheotherpotentialeffectsare:• Decreaseinfertility• Foetalmalformation• Abortion• Extrauterinepregnancy• Hightoxicityforcertainorgans.
• Alwaysweargloveswhenhandlingthedrug - Avoidtouchingthedrug - Washhandsbeforeputtingglovesonandafterwearinggloves.
• Glovesusedforprotectionagainstchemotherapydrugsmustbeselected specificallyforthetypeofchemicalsused.
• Usemedicalgrade,sterileornonsterile,glovesdependingonthetechnique recommendedbyyourhealthcarefacility.
• Alwaysusepowder-freegloves. - Glovepowdersmaycontaminatechemotherapyworkarea.
• Choosealatex,nitrileorneopreneglove - Polyvinylchloride(PVC)glovesarenotrecommendedforhandling chemothapydrugs.
• Usethickglovesthatextendoverthecuffoftheprotectivegown. - Double-glovingisstronglyadvisedwhenthereisariskofexposition duringpreparationoradministrationofchemotherapydrugs. - Ifdouble-gloving,insertfirstgloveunderthecuffandplacethesecond glove over the cuff.
• Beforehandlingchemotherapydrugs, - Observeglovesforanybreakinbarrier.
• Changeglovesaftereachuse,tear,punctureormedicationspillorafter 30minutesofwear.
• Uponremoval,bothglovesneedtobeturnedinsideout - Neverflick,snap,ortossyourgloves.
• Followrecommendationsimplementedbyyourhealthcarefacilityforthe disposal of gloves.
• Toujoursutiliserdesgantspourlamanipulationdesmédicaments dechimiothérapie - Évitertoutcontactdirectavecleproduit - Selaverlesmainsavantetaprèsleportdegants.
• Lesgantsutiliséspourlaprotectioncontrelesproduitscytotoxiquesdoivent êtresélectionnésspécifiquementselonlesproduitschimiquesutilisés.
• Utiliserungantmédicalstérileounonstérileselonlatechnique recommandéeparvotrecentredesanté.
• Toujoursutiliserdesgantssanspoudre. - Lapoudredesgantspeutcontaminerlelieudetravail.
• Choisirungantenlatex,nitrileounéoprène. - Lesgantsenchloruredepolyvinyle(PVC)nesontpasrecommandéspour lamanipulationdemédicamentsdechimiothérapie.
• Porterdesgantsépaisquicouvrentbienlepoignetetlablouse. - Lorsdelapréparationetl’administrationdeproduitscytotoxiques,s’ilya undangerd’exposition,ledoublegantageestderigueur. - Sil’onsuperposelesgants,lapremièrepaireprotègelapeauetla deuxièmepairerecouvrelablouse.
• Avantdemanipulerlesproduitscytotoxiques - Vérifiersilabarrièredeprotectiondesgantsestintacte.
• Changerdegantsaprèschaqueapplication,sicontaminés,déchirés,troués ouàtoutesles30minutesd’utilisation.
• Pourretirerlesgants,tourneràl’enverssanstoucherlasurfacecontaminée - Éviterdelesclaquer,fouetterouremuerinutilement.
• Disposerdesgantsselonlesrecommandationsdevotrecentredesanté.
Pourquoi des tests spécifiques à la perméation des produits cytotoxiques ?L’Organisation mondiale de la Santé prévoit une progression du cancer de 50%d’ici2020,soitenviron15millionsdenouveauxcasdecancersparanàl’échellemondiale.
Lacausedecetteaugmentationprévuerésideprincipalementdanslevieillissementdes populations, tant dans les pays développés que dans les pays en voie dedéveloppement. La croissance du tabagisme ainsi que la généralisation demauvaiseshabitudesdevienesontpasétrangèresàlamultiplicationdescasdecancers.
La chimiothérapie figure parmi les traitements les plus fréquemment utiliséspour combattre le cancer. Or, on sait que les cytostatiques sont potentiellementdangereuxpourceluiquilesmanipule(pharmacien,assistant,infirmière,chirurgien[techniqueCHIP]etc.).
Lescytostatiquessontréputés:• mutagènes(ex.:provoquentouaugmententlesmutationsgénétiquesen changeantl’ADN)• carcinogènespourcertainsanimauxdelaboratoire,pourlespatients oulesdeux• tératogènesouproblèmesdefertilitésurlesanimauxétudiésou sur les patients traités.
Ilspeuventégalementprovoquerleseffetssecondairessuivants:• diminutiondelafécondité• malformationsfœtales• avortements• grossessesextrautérines• hautrisqued’intoxicationdecertainsorganes.
Glove characteristicsCaractéristiques du gant
Cytostatic characteristicsCaractéristiques du cytostatique
Room parameters Paramètres ambiants
Permeation rateTaux de perméation
WorkerTravailleur
OtherAutres
Exposure time Durée d’exposition
Permeationdependsonmanyparametersandthereforetheresultsobtainedcannotbeextendedtoanyothermaterial,brandorcompetitiveproduct.
Letempsdeperméationdépenddeplusieursparamètres.Lesrésultatsobtenusnepeuventêtreextrapolésàaucuneautrematière,marqueouproduitconcurrent.
Permeation : a very complex processla perméation : un processus très complexe
• Revolutionaryanti-slipcuffadherestoalltypesofgowns• Eliminatescuffroll-down
• Bandeadhésiveauxpoignetsquipermetauxgantsdetenirbienen placesurtouslestypesdeblouseschirurgicales• Élimineleproblèmed’enroulement
assurance qualité ansellansell Quality assurance