Upload
sreekanth-raveendran
View
227
Download
0
Embed Size (px)
Citation preview
8/12/2019 Galley Lighting Design Report_Detailed
1/43
Date:2/26/2014
Gurban Abasov_Galley Refurbishment
8/12/2019 Galley Lighting Design Report_Detailed
2/43
Table of contents
Gurban Abasov_Galley RefurbishmentSite 1
Building 1
Storey 1Room 1Room summary....................................................................................................................................................................................... 4Luminaire parts list...................................................................................................................................................................................5Results summary of surfaces.................................................................................................................................................................. 6
Workplane 1Value chart/Perpendicular illuminance (adaptive)...............................................................................................................................7
Room 2Room summary....................................................................................................................................................................................... 8
Workplane 2Valu e chart/Perpendicular illuminance (adaptive)...............................................................................................................................9
Room 3Room summary..................................................................................................................................................................................... 10
Wor kplane 3Value chart/Perpendicular il luminance (adaptive).............................................................................................................................11
Room 4Room s ummary..................................................................................................................................................................................... 12
Workplane 4Value chart/Perpendicular il luminance (adaptive).............................................................................................................................13
Room 5Room summary..................................................................................................................................................................................... 14
Workplane 5Valu e chart/Perpendicular il luminance (adaptive).............................................................................................................................16
Room 6Room summary..................................................................................................................................................................................... 17
Wor kplane 6Value chart/Perpendicular il luminance (adaptive).............................................................................................................................19
Room 7Room summary..................................................................................................................................................................................... 20
Workplane 7Value chart/Perpendicular il luminance (adaptive).............................................................................................................................22
Room 8Room summary..................................................................................................................................................................................... 23
Workplane 8Value chart/Perpendicular il luminance (adaptive).............................................................................................................................25
Room 9Room summary..................................................................................................................................................................................... 26
Workplane 9Value chart/Perpendicular il luminance (adaptive).............................................................................................................................28
Room 10Workplane 10Value chart/Perpendicular il luminance (adaptive).............................................................................................................................29
Room 11Room summary..................................................................................................................................................................................... 30
Workplane 11Value chart/Perpendicular il luminance (adaptive).............................................................................................................................31
Room 3 Working PlaneRoom summary..................................................................................................................................................................................... 32
Workplane 12Results overview............................................................................................................................................................................... 33Value chart/Perpendicular il luminance (adaptive).............................................................................................................................34
Room-6 Oven TopRoom summary..................................................................................................................................................................................... 35
Workplane 13
Gurban Abasov_Galley Refurbishment 2/26/2014
Gurban Abasov_Galley Refurbishment / Table of contents
Page 2
8/12/2019 Galley Lighting Design Report_Detailed
3/43
Results overview............................................................................................................................................................................... 37Value chart/Perpendicular il luminance (adaptive).............................................................................................................................38
Room-8 Working PlaneRoom summary..................................................................................................................................................................................... 39Room-10 Working Plane
Room summary..................................................................................................................................................................................... 41Workplane 15Results overview............................................................................................................................................................................... 42Value chart/Perpendicular il luminance (adaptive).............................................................................................................................43
Gurban Abasov_Galley Refurbishment 2/26/2014
Gurban Abasov_Galley Refurbishment / Table of contents
Page 3
8/12/2019 Galley Lighting Design Report_Detailed
4/43
Room 1 / Room summary
Scale: 1 : 25
Perpendicular illuminance (adaptive)Name Average [lx] Min [lx] Max [lx] Min/average Min/max Points (Relevant)
Workplane 1 514 373 619 0.726 0.603 32 x 32 (all)
Height of room: 2.800 m, Reflection factors: Ceiling 61.4%, Walls 81.9%, Floor 27.9%, Light loss factor: 0.80
No. Quantity
1 2 Glamox DLT RS(M)284 218 FR2Light output ratio: 43.82%
See our luminaire catalog for an image of the luminaire.
80
120
cd/klm = 44%C0 - C 180 C90 - C270
0 15 30
45
60
75
90
105105
90
75
60
45
30 15 0
Total luminous flux: 5400 lm, Total Load: 96 W
Specific connection value: 0.00 W/m = 0.00 W/m/100 lx (Ground area 0.00 m)
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 1 / Room summary
Page 4
8/12/2019 Galley Lighting Design Report_Detailed
5/43
Room 1 / Luminaire parts list1.) 2 x Glamox DLT RS(M)284 218 FR2
See our luminaire catalogfor an image of the
luminaire.
80
120
cd/klm = 44%C0 - C180 C90 - C270
0 15 30
45
60
75
90
105105
90
75
60
45
30 15 0
Luminous emittance 1
Fitting: 2xT8 18 WLight output ratio: 43.82%
Total luminous flux: 5400 lm, Total Load: 96 W
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 1 / Luminaire parts list
Page 5
8/12/2019 Galley Lighting Design Report_Detailed
6/43
Room 1 / Results summary of surfaces
Perpendicular illuminance (adaptive)Name Average [lx] Min [lx] Max [lx] Min/average Min/max Points (Relevant)
Workplane 1 514 373 619 0.726 0.603 32 x 32 (all)
Height of room: 2.800 m, Reflection factors: Ceiling 61.4%, Walls 81.9%, Floor 27.9%, Light loss factor: 0.80
Relevant points are points that are within the respective surface and are not covered by furniture or other elements. The summarized results are basedexclusively on these points, as all other points would falsify the results, in some cases significantly.
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 1 / Results summary of surfaces
Page 6
8/12/2019 Galley Lighting Design Report_Detailed
7/43
Workplane 1 / Value chart/Perpendicular illuminance (adaptive)
Scale: 1 : 25
Perpendicular illuminance (Surface) Average: 514 lx, Min: 373 lx, Max: 619 lx, Min/average: 0.726, Min/max: 0.603, Points: 32 x 32 (Relevant: all)
Height of working plane: 1.000 m, Wall zone: 0.000 m
Relevant points are points that are within the respective surface and are not covered by furniture or other elements. The summarized results are basedexclusively on these points, as all other points would falsify the results, in some cases significantly.
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 1 / Workplane 1 / Value chart/Perpendicular illuminance (adaptive)
Page 7
8/12/2019 Galley Lighting Design Report_Detailed
8/43
Room 2 / Room summary
Scale: 1 : 25
Perpendicular illuminance (adaptive)Name Average [lx] Min [lx] Max [lx] Min/average Min/max Points (Relevant)
Workplane 2 443 267 551 0.603 0.485 32 x 32 (1021)
Height of room: 2.800 m, Reflection factors: Ceiling 61.4%, Walls 77.1%, Floor 27.9%, Light loss factor: 0.80
No. Quantity
1 2 Glamox DLT RS(M)284 218 FR2Light output ratio: 43.82%
See our luminaire catalog for an image of the luminaire.
80
120
cd/klm = 44%C0 - C 180 C90 - C270
0 15 30
45
60
75
90
105105
90
75
60
45
30 15 0
Total luminous flux: 5400 lm, Total Load: 96 W
Specific connection value: 0.00 W/m = 0.00 W/m/100 lx (Ground area 0.00 m)
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 2 / Room summary
Page 8
8/12/2019 Galley Lighting Design Report_Detailed
9/43
Workplane 2 / Value chart/Perpendicular illuminance (adaptive)
Scale: 1 : 25
Perpendicular illuminance (Surface) Average: 443 lx, Min: 267 lx, Max: 551 lx, Min/average: 0.603, Min/max: 0.485, Points: 32 x 32 (Relevant: 1021)
Height of working plane: 1.000 m, Wall zone: 0.000 m
Relevant points are points that are within the respective surface and are not covered by furniture or other elements. The summarized results are basedexclusively on these points, as all other points would falsify the results, in some cases significantly.
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 2 / Workplane 2 / Value chart/Perpendicular illuminance (adaptive)
Page 9
8/12/2019 Galley Lighting Design Report_Detailed
10/43
Room 3 / Room summary
Scale: 1 : 25
Perpendicular illuminance (adaptive)Name Average [lx] Min [lx] Max [lx] Min/average Min/max Points (Relevant)
Workplane 12 312 80 502 0.257 0.159 64 x 32 (1866)
Workplane 3 237 0.37 444 0.002 0.001 32 x 64 (2046)Summary / 0.37 502 / /
Height of room: 2.800 m, Reflection factors: Ceiling 61.4%, Walls 65.8%, Floor 27.6%, Light loss factor: 0.80
No. Quantity
1 5 Glamox DLT RS(M)284 218 FR2Light output ratio: 43.82%
See our luminaire catalog for an image of the luminaire.
80
120
cd/klm = 44%C0 - C 180 C90 - C270
0 15 30
45
60
75
90
105105
90
75
60
45
30 15 0
Total luminous flux: 13500 lm, Total Load: 240 W
Specific connection value: 0.00 W/m = 0.00 W/m/100 lx (Ground area 0.00 m)
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 3 / Room summary
Page 10
8/12/2019 Galley Lighting Design Report_Detailed
11/43
8/12/2019 Galley Lighting Design Report_Detailed
12/43
Room 4 / Room summary
Scale: 1 : 25
Perpendicular illuminance (adaptive)Name Average [lx] Min [lx] Max [lx] Min/average Min/max Points (Relevant)
Workplane 4 425 278 549 0.654 0.506 128 x 64 (8123)
Height of room: 2.800 m, Reflection factors: Ceiling 61.4%, Walls 69.3%, Floor 27.8%, Light loss factor: 0.80
No. Quantity
1 4 Glamox DLT RS(M)284 218 FR2Light output ratio: 43.82%
See our luminaire catalog for an image of the luminaire.
80
120
cd/klm = 44%C0 - C 180 C90 - C270
0 15 30
45
60
75
90
105105
90
75
60
45
30 15 0
Total luminous flux: 10800 lm, Total Load: 192 W
Specific connection value: 0.00 W/m = 0.00 W/m/100 lx (Ground area 0.00 m)
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 4 / Room summary
Page 12
8/12/2019 Galley Lighting Design Report_Detailed
13/43
Workplane 4 / Value chart/Perpendicular illuminance (adaptive)
Scale: 1 : 25
Perpendicular illuminance (Surface) Average: 425 lx, Min: 278 lx, Max: 549 lx, Min/average: 0.654, Min/max: 0.506, Points: 128 x 64 (Relevant: 8123)
Height of working plane: 1.000 m, Wall zone: 0.000 m
Relevant points are points that are within the respective surface and are not covered by furniture or other elements. The summarized results are basedexclusively on these points, as all other points would falsify the results, in some cases significantly.
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 4 / Workplane 4 / Value chart/Perpendicular illuminance (adaptive)
Page 13
8/12/2019 Galley Lighting Design Report_Detailed
14/43
Room 5 / Room summary
Scale: 1 : 25
Perpendicular illuminance (adaptive)Name Average [lx] Min [lx] Max [lx] Min/average Min/max Points (Relevant)
Workplane 5 398 374 423 0.941 0.885 8 x 1 (all)
Height of room: 2.800 m, Reflection factors: Ceiling 61.4%, Walls 77.5%, Floor 27.6%, Light loss factor: 0.80
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 5 / Room summary
Page 14
8/12/2019 Galley Lighting Design Report_Detailed
15/43
No. Quantity
1 4 Glamox DLT RS(M)284 218 FR2Light output ratio: 43.82%
See our luminaire catalog for an image of the luminaire.
80
120
cd/klm = 44%C0 - C 180 C90 - C270
0 15 30
45
60
75
90
105105
90
75
60
45
30 15 0
Total luminous flux: 10800 lm, Total Load: 192 W
Specific connection value: 0.00 W/m = 0.00 W/m/100 lx (Ground area 0.00 m)
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 5 / Room summary
Page 15
8/12/2019 Galley Lighting Design Report_Detailed
16/43
Workplane 5 / Value chart/Perpendicular illuminance (adaptive)
Scale: 1 : 25Perpendicular illuminance (Surface)
Average: 512 lx, Min: 185 lx, Max: 702 lx, Min/average: 0.360, Min/max: 0.263, Points: 128 x 256 (Relevant: 31339)
Height of working plane: 1.000 m, Wall zone: 0.000 m
Relevant points are points that are within the respective surface and are not covered by furniture or other elements. The summarized results are basedexclusively on these points, as all other points would falsify the results, in some cases significantly.
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 5 / Workplane 5 / Value chart/Perpendicular illuminance (adaptive)
Page 16
8/12/2019 Galley Lighting Design Report_Detailed
17/43
Room 6 / Room summary
Scale: 1 : 25
Perpendicular illuminance (adaptive)Name Average [lx] Min [lx] Max [lx] Min/average Min/max Points (Relevant)
Workplane 6 266 37 449 0.141 0.083 64 x 64 (4070)
Workplane 13 107 38 264 0.354 0.144 32 x 32 (all)
Summary / 37 449 / /
Height of room: 2.800 m, Reflection factors: Ceiling 61.4%, Walls 83.8%, Floor 27.5%, Light loss factor: 0.80
No. Quantity1 2 Glamox DLT RS(M)284 218 FR2
Light output ratio: 43.82%
See our luminaire catalog for an image of the luminaire.
80
120
cd/klm = 44%C0 - C 180 C90 - C270
0 15 30
45
60
75
90
105105
90
75
60
45
30 15 0
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 6 / Room summary
Page 17
8/12/2019 Galley Lighting Design Report_Detailed
18/43
No. Quantity
2 1 Glamox MIRZ54 236 PCLight output ratio: 71.50%
See our luminaire catalog for an image of the luminaire.
80
120
160
cd/klm = 72%C0 - C 180 C90 - C270
0 15 30 45
60
75
90
105
120
135150165180165150135
120
105
90
75
60
45 30 15 0
Total luminous flux: 12100 lm, Total Load: 166 W
Specific connection value: 0.00 W/m = 0.00 W/m/100 lx (Ground area 0.00 m)
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 6 / Room summary
Page 18
8/12/2019 Galley Lighting Design Report_Detailed
19/43
Workplane 6 / Value chart/Perpendicular illuminance (adaptive)
Scale: 1 : 25
Perpendicular illuminance (Surface) Average: 311 lx, Min: 306 lx, Max: 315 lx, Min/average: 0.984, Min/max: 0.969, Points: 2 x 1 (Relevant: all)
Height of working plane: 1.000 m, Wall zone: 0.000 m
Relevant points are points that are within the respective surface and are not covered by furniture or other elements. The summarized results are basedexclusively on these points, as all other points would falsify the results, in some cases significantly.
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 6 / Workplane 6 / Value chart/Perpendicular illuminance (adaptive)
Page 19
8/12/2019 Galley Lighting Design Report_Detailed
20/43
Room 7 / Room summary
Scale: 1 : 25
Perpendicular illuminance (adaptive)Name Average [lx] Min [lx] Max [lx] Min/average Min/max Points (Relevant)
Workplane 7 523 220 663 0.421 0.332 64 x 64 (3979)
Height of room: 2.800 m, Reflection factors: Ceiling 61.4%, Walls 83.6%, Floor 27.4%, Light loss factor: 0.80
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 7 / Room summary
Page 20
8/12/2019 Galley Lighting Design Report_Detailed
21/43
No. Quantity
1 6 Glamox DLT RS(M)284 218 FR2Light output ratio: 43.82%
See our luminaire catalog for an image of the luminaire.
80
120
cd/klm = 44%C0 - C 180 C90 - C270
0 15 30
45
60
75
90
105105
90
75
60
45
30 15 0
Total luminous flux: 16200 lm, Total Load: 288 W
Specific connection value: 0.00 W/m = 0.00 W/m/100 lx (Ground area 0.00 m)
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 7 / Room summary
Page 21
8/12/2019 Galley Lighting Design Report_Detailed
22/43
8/12/2019 Galley Lighting Design Report_Detailed
23/43
Room 8 / Room summary
Scale: 1 : 50
Perpendicular illuminance (adaptive)Name Average [lx] Min [lx] Max [lx] Min/average Min/max Points (Relevant)
Workplane 8 422 0.52 977 0.001 0.001 64 x 128 (6370)
Workplane 14 553 216 1077 0.391 0.201 512 x 256 (90697)
Summary / 0.52 1077 / /
Height of room: 2.800 m, Reflection factors: Ceiling 61.4%, Walls 65.4%, Floor 27.5%, Light loss factor: 0.80
No. Quantity
1 6 Glamox DLT RS(M)284 218 FR2Light output ratio: 43.82%
See our luminaire catalog for an image of the luminaire.
80
120
cd/klm = 44%C0 - C 180 C90 - C270
0 15 30
45
60
75
90
105105
90
75
60
45
30 15 0
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 8 / Room summary
Page 23
8/12/2019 Galley Lighting Design Report_Detailed
24/43
Total luminous flux: 16200 lm, Total Load: 288 W
Specific connection value: 15.91 W/m = 3.77 W/m/100 lx (Ground area 18.10 m)
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 8 / Room summary
Page 24
8/12/2019 Galley Lighting Design Report_Detailed
25/43
Workplane 8 / Value chart/Perpendicular illuminance (adaptive)
Scale: 1 : 50
Perpendicular illuminance (Surface) Average: 422 lx, Min: 0.52 lx, Max: 977 lx, Min/average: 0.001, Min/max: 0.001, Points: 64 x 128 (Relevant: 6370)
Height of working plane: 0.800 m, Wall zone: 0.000 m
Relevant points are points that are within the respective surface and are not covered by furniture or other elements. The summarized results are basedexclusively on these points, as all other points would falsify the results, in some cases significantly.
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 8 / Workplane 8 / Value chart/Perpendicular illuminance (adaptive)
Page 25
8/12/2019 Galley Lighting Design Report_Detailed
26/43
Room 9 / Room summary
Scale: 1 : 25
Perpendicular illuminance (adaptive)Name Average [lx] Min [lx] Max [lx] Min/average Min/max Points (Relevant)
Workplane 9 390 218 505 0.558 0.431 128 x 128 (16290)
Height of room: 2.800 m, Reflection factors: Ceiling 61.4%, Walls 83.9%, Floor 27.5%, Light loss factor: 0.80
No. Quantity
1 4 Glamox DLT RS(M)284 218 FR2Light output ratio: 43.82%
See our luminaire catalog for an image of the luminaire.
80
120
cd/klm = 44%C0 - C 180 C90 - C270
0 15 30
45
60
75
90
105105
90
75
60
45
30 15 0
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 9 / Room summary
Page 26
8/12/2019 Galley Lighting Design Report_Detailed
27/43
8/12/2019 Galley Lighting Design Report_Detailed
28/43
Workplane 9 / Value chart/Perpendicular illuminance (adaptive)
Scale: 1 : 25
Perpendicular illuminance (Surface) Average: 390 lx, Min: 218 lx, Max: 505 lx, Min/average: 0.558, Min/max: 0.431, Points: 128 x 128 (Relevant: 16290)
Height of working plane: 1.000 m, Wall zone: 0.000 m
Relevant points are points that are within the respective surface and are not covered by furniture or other elements. The summarized results are basedexclusively on these points, as all other points would falsify the results, in some cases significantly.
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 9 / Workplane 9 / Value chart/Perpendicular illuminance (adaptive)
Page 28
8/12/2019 Galley Lighting Design Report_Detailed
29/43
8/12/2019 Galley Lighting Design Report_Detailed
30/43
Room 11 / Room summary
Scale: 1 : 50
Perpendicular illuminance (adaptive)
Name Average [lx] Min [lx] Max [lx] Min/average Min/max Points (Relevant)Workplane 11 1218 758 1451 0.623 0.522 16 x 64 (all)
Height of room: 2.800 m, Reflection factors: Ceiling 56.8%, Walls 57.3%, Floor 20.0%, Light loss factor: 0.80
No. Quantity
1 3 Glamox MIRZ54 236 PCLight output ratio: 71.50%
See our luminaire catalog for an image of the luminaire.
80
120
160
cd/klm = 72%C0 - C 180 C90 - C270
0 15 30 45
60
75
90
105
120
135150165180165150135
120
105
90
75
60
45 30 15 0
Total luminous flux: 20100 lm, Total Load: 210 W
Specific connection value: 0.00 W/m = 0.00 W/m/100 lx (Ground area 0.00 m)
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 11 / Room summary
Page 30
8/12/2019 Galley Lighting Design Report_Detailed
31/43
Workplane 11 / Value chart/Perpendicular illuminance (adaptive)
Scale: 1 : 50
Perpendicular illuminance (Surface)
Average: 1218 lx, Min: 758 lx, Max: 1451 lx, Min/average: 0.623, Min/max: 0.522, Points: 16 x 64 (Relevant: all)
Height of working plane: 1.000 m, Wall zone: 0.000 m
Relevant points are points that are within the respective surface and are not covered by furniture or other elements. The summarized results are basedexclusively on these points, as all other points would falsify the results, in some cases significantly.
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 11 / Workplane 11 / Value chart/Perpendicular illuminance (adaptive)
Page 31
8/12/2019 Galley Lighting Design Report_Detailed
32/43
8/12/2019 Galley Lighting Design Report_Detailed
33/43
Workplane 12 / Results overview
Results overview (Surface)Result type Average Min Max Min/average Min/max Points (Relevant)
Perpendicular illuminance [lx] 312 80 502 0.257 0.159 64 x 32 (1866)
Height of working plane: 1.000 m, Wall zone: 0.000 m
Relevant points are points that are within the respective surface and are not covered by furniture or other elements. The summarized results are basedexclusively on these points, as all other points would falsify the results, in some cases significantly.
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 3 Working Plane / Workplane 12 / Results overview
Page 33
8/12/2019 Galley Lighting Design Report_Detailed
34/43
Workplane 12 / Value chart/Perpendicular illuminance (adaptive)
Scale: 1 : 25
Perpendicular illuminance (Surface) Average: 312 lx, Min: 80 lx, Max: 502 lx, Min/average: 0.257, Min/max: 0.159, Points: 64 x 32 (Relevant: 1866)
Height of working plane: 1.000 m, Wall zone: 0.000 m
Relevant points are points that are within the respective surface and are not covered by furniture or other elements. The summarized results are basedexclusively on these points, as all other points would falsify the results, in some cases significantly.
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room 3 Working Plane / Workplane 12 / Value chart/Perpendicular illuminance (adaptive)
Page 34
8/12/2019 Galley Lighting Design Report_Detailed
35/43
Room-6 Oven Top / Room summary
Scale: 1 : 10
Perpendicular illuminance (adaptive)Name Average [lx] Min [lx] Max [lx] Min/average Min/max Points (Relevant)
Workplane 13 107 38 264 0.354 0.144 32 x 32 (all)
Height of room: 2.800 m, Reflection factors: Ceiling 65.2%, Walls 57.4%, Floor 26.6%, Light loss factor: 0.70
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room-6 Oven Top / Room summary
Page 35
8/12/2019 Galley Lighting Design Report_Detailed
36/43
No. Quantity
1 1 Glamox MIRZ54 236 PCLight output ratio: 71.50%
See our luminaire catalog for an image of the luminaire.
80
120
160
cd/klm = 72%C0 - C 180 C90 - C270
0 15 30 45
60
75
90
105
120
135150165180165150135
120
105
90
75
60
45 30 15 0
Total luminous flux: 6700 lm, Total Load: 70 W
Specific connection value: 0.00 W/m = 0.00 W/m/100 lx (Ground area 0.00 m)
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room-6 Oven Top / Room summary
Page 36
8/12/2019 Galley Lighting Design Report_Detailed
37/43
Workplane 13 / Results overview
Results overview (Surface)Result type Average Min Max Min/average Min/max Points (Relevant)
Perpendicular illuminance [lx] 107 38 264 0.354 0.144 32 x 32 (all)
Height of working plane: 1.000 m, Wall zone: 0.000 m
Relevant points are points that are within the respective surface and are not covered by furniture or other elements. The summarized results are basedexclusively on these points, as all other points would falsify the results, in some cases significantly.
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room-6 Oven Top / Workplane 13 / Results overview
Page 37
8/12/2019 Galley Lighting Design Report_Detailed
38/43
Workplane 13 / Value chart/Perpendicular illuminance (adaptive)
Scale: 1 : 10
Perpendicular illuminance (Surface) Average: 107 lx, Min: 38 lx, Max: 264 lx, Min/average: 0.354, Min/max: 0.144, Points: 32 x 32 (Relevant: all)
Height of working plane: 1.000 m, Wall zone: 0.000 m
Relevant points are points that are within the respective surface and are not covered by furniture or other elements. The summarized results are basedexclusively on these points, as all other points would falsify the results, in some cases significantly.
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room-6 Oven Top / Workplane 13 / Value chart/Perpendicular illuminance (adaptive)
Page 38
8/12/2019 Galley Lighting Design Report_Detailed
39/43
Room-8 Working Plane / Room summary
Scale: 1 : 50
Perpendicular illuminance (adaptive)Name Average [lx] Min [lx] Max [lx] Min/average Min/max Points (Relevant)
Workplane 8 422 0.52 977 0.001 0.001 64 x 128 (6370)
Workplane 14 553 216 1077 0.391 0.201 512 x 256 (90697)
Summary / 0.52 1077 / /
Height of room: 2.800 m, Reflection factors: Ceiling 63.6%, Walls 56.3%, Floor 27.5%, Light loss factor: 0.70
No. Quantity
1 6 Glamox DLT RS(M)284 218 FR2Light output ratio: 43.82%
See our luminaire catalog for an image of the luminaire.
80
120
cd/klm = 44%C0 - C 180 C90 - C270
0 15 30
45
60
75
90
105105
90
75
60
45
30 15 0
Total luminous flux: 16200 lm, Total Load: 288 W
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room-8 Working Plane / Room summary
Page 39
8/12/2019 Galley Lighting Design Report_Detailed
40/43
Specific connection value: 15.91 W/m = 2.88 W/m/100 lx (Ground area 18.10 m)
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room-8 Working Plane / Room summary
Page 40
8/12/2019 Galley Lighting Design Report_Detailed
41/43
8/12/2019 Galley Lighting Design Report_Detailed
42/43
Workplane 15 / Results overview
Results overview (Surface)Result type Average Min Max Min/average Min/max Points (Relevant)
Perpendicular illuminance [lx] 347 118 511 0.341 0.232 512 x 256 (92904)
Height of working plane: 1.000 m, Wall zone: 0.000 m
Relevant points are points that are within the respective surface and are not covered by furniture or other elements. The summarized results are basedexclusively on these points, as all other points would falsify the results, in some cases significantly.
Gurban Abasov_Galley Refurbishment 2/26/2014
Site 1 / Building 1 / Storey 1 / Room-10 Working Plane / Workplane 15 / Results overview
Page 42
8/12/2019 Galley Lighting Design Report_Detailed
43/43