    | INTERFACE BOX | | D C S S |

    (security link) | | | |

    EDS --------->+ +---> ---------> /EDS (110V) |

    TCI --------->+ +---> ---------> /TCI (110V) |

    | .----. | | |

    SGSin -------->+----->+ & | | | |

    EFS -------->+--+-->+ +---->+--------------> DOB (30V) |

    | | `----' | | |

    Forced Close-->+ +--------------+--------------> /NDG (to HL2) |

    | | | |

    (controller sig.) | | | |

    DO --------->+--+--- DO ---+->+--------------> DO (30V) |

    DC ------------>+----DO/DC--+ | | |

    | | | |

    Int.SPEED ---->+ +--------------> /SO (to HL2) |

    | | | |

    | | | |

    (outputs) | .-------. | | |

  • 7/25/2019 GAA 24350 AW11 II.pdf

    8/22

    Interface Signal: DCSS input:

    Name | Connector || Name | Connector

    volt. range | IN --> OUT || |

    -------------------------------------------------------------------------

    EDS Emergency Door Stop (Safety Link) || |

    48 to 110V | P7/10 to P7/12 --> P3/2 || EDS | P2.1 (110Vac)

    >110V | P7/11 to P7/12 --> || | -----------------------------------------------++---------+--------------

    TCI Top of Car Inspection (Safety Link) || |

    48 to 110V | P7/7 to P7/9 --> P3/3 || TCI | P2.2 (110Vac)

    >110V | P7/8 to P7/9 --> || |

    -----------------------------------------------++---------+--------------

    SGSin Reversal Signal Input || |

    48 to 110V | P7/4 to P7/6 --> P5/10 || DOB | P5.7 (30V)

    >110V | P7/5 to P7/6 --> || | note 1

    -----------------------------------------------++---------+--------------

    EFS Emergency Fireman Service ||

    48 to 110V | P7/1 to P7/3 ||

    >110V | P7/2 to P7/3 || note 1

    -----------------------------------------------++---------+--------------

    DO Door Open Signal || |

    48 to 110V | P6/10 to P6/12 --> P5/9 || DO | P5.8 (30V)

    >110V | P6/11 to P6/12 --> || | note 2

    -----------------------------------------------++---------+---------------

    DC Door Close Signal ||

    48 to 110V | P6/7 to P6/9 ||

    >110V | P6/8 to P6/9 || note 2

    -----------------------------------------------++---------+---------------

    2nd Prof Second Speed Prof. Signal || |

    48 to 110V | P6/4 to P6/6 --> P5/11 || /SO | P5.4 (to HL2)

    >110V | P6/5 to P6/6 --> || | note 3

    -----------------------------------------------++---------+--------------- NDG Nudging (forced closing) || |

    48 to 110V | P6/1 to P6/3 --> P5/12 || NDG | P5.5 (to HL2)

    >110V | P6/2 to P6/3 --> || |

    -----------------------------------------------++---------+---------------

  • 7/25/2019 GAA 24350 AW11 II.pdf

    9/22

    Name Plug Description

    Brake / Make cont.

    ---------------------------------------------------------------------

    REL1 | P4/1-3 / P4/1-2 | used as Door Open Limit switch (DOL)

    | | ------+-----------------------+---------------------------------------

    REL2 | P4/4-6 / P4/4-5 | Set before door is fully closed (XMC)

    | | (used for gearless elevator)

    ------+-----------------------+---------------------------------------

    REL3 | P4/7-9 / P4/7-8 | used as Door Fully Closed (DCL)

    | |

    ------+-----------------------+---------------------------------------

    REL4 | P4/10-12 / P4/10-11 | used as SGL signal

    | | Signal to weak the sensitivity of EDP

    ------+-----------------------+---------------------------------------

    REL5 | P5/1-3 / P5/1-2 | Set before door is fully closed (PMY)

    | | (used for high speed drive)

    ------+-----------------------+---------------------------------------

    REL6 | P5/4-6 / P5/4-5 | Door reopen signal with adjustable

    | | delay (SGSout)

    ------+-----------------------+---------------------------------------

  • 7/25/2019 GAA 24350 AW11 II.pdf

    10/22

  • 7/25/2019 GAA 24350 AW11 II.pdf

    11/22

    ,-----------------.

    | SET UP ROUTINE |

    | GOON WITH ENTER |

    `-----------------'

    ,-------------------.

    | DEFAULT PARAMETER?|

  • 7/25/2019 GAA 24350 AW11 II.pdf

    12/22

    | YES = 1 NO = 2 |

    `-------------------'

    ,-------------------.

    | Interf: nnnnnnnn | nnnnnnn = DISCRETE

    | use GOON / ENTER | SERIAL

    `-------------------' Interf.BOX

  • 7/25/2019 GAA 24350 AW11 II.pdf

    13/22

    ,------------------.

    | ADDRESS: nnnnnn | nnnnnn = DCSS_1 | use GOON / ENTER | DCSS_2

    `------------------' DCSS_3

    DCSS_4

    ,------------------.

    | LINE TERMINATOR |

    | YES = 1 NO = 2 |

    `------------------'

    ,------------------.

    | CONTROLLER TYPE: |

    | use GOON / ENTER |

    `------------------'

    ,------------------. ,------------------. | Type: MCS 411 | OR | Other (311...) |

    | use GOON / ENTER | | use GOON / ENTER |

    `------------------' `------------------

    ,------------------.

    | DOS Signal ? |

    | YES = 1 NO = 0 |

    `------------------'

  • 7/25/2019 GAA 24350 AW11 II.pdf

    14/22

  • 7/25/2019 GAA 24350 AW11 II.pdf

    15/22

    ,------------------.

    | CHK MOTOR ROTATN |

    | CLS=1 OPN=2 NO=3 |

    `------------------'

    ,------------------.

    | DOOR IS nnnn | nnnn = OPENING

    | YES=1 NO=2 | CLOSING

    `------------------'

    ,-----------------.

    | ERR ROTOR SENSE |

    | GOON WITH ENTER |

    `-----------------'

    ,------------------.

    | ROTOR SENSE OK |

    | GOON WITH ENTER |

    `------------------'

    ,------------------.

    | CHECK ENCODER |

    | CLS=1 OPN=2 NO=3 |

    `------------------'

    ,------------------.

    | ENCODER OK? nn | nn = >< (closing)

    | YES = 1 NO = 2| (opening)

    `------------------'

  • 7/25/2019 GAA 24350 AW11 II.pdf

    16/22

    ,------------------.

    | ENCODER SENSE OK |

    | GOON WITH ENTER |

    `------------------'

    ,------------------. Start Learn Run.

    1) | START LEARN RUN |

    | PRESS |

    `------------------'

    ,------------------. Find closed position.

    2) | LEARN RUN |

    | DOOR is CLOSING |

    `------------------'

    3) ,------------------. Check encoder signals.

    | LEARN RUN |

    | DOOR is OPENING |

    `------------------'

    4) ,------------------. Learning the door way.

    | LEARN RUN | | POSITION: xx[mm]|

    `------------------'

    5) ,------------------. Confirm the door way and

    |POSITION: xx [mm]| leave Installation Run with

    | FINISH PRESS "M" | the "M"odule Key.

    `------------------'

  • 7/25/2019 GAA 24350 AW11 II.pdf

    17/22

  • 7/25/2019 GAA 24350 AW11 II.pdf

    18/22

  • 7/25/2019 GAA 24350 AW11 II.pdf

    19/22

    []

    Output: Parameter Setting: Relay is:

    ][ ...............[]

    REL_1 : distance to fully open _________________XXX

    REL_2 : distance to fully closed XXXX________________ REL_3 : distance to fully closed XXX_________________ note 1)

    REL_4_CLOSE: distance to fully closed

    REL_4_OPEN: distance to fully open XXX______________XXX

    REL_5 : distance to fully close XXX_________________

    XXX relay is on

    ___ relay is off

    REL_6 : delay time in [ms]

    REL6 is time controlled and triggered with the SGSinput signal.

    The Time delay is programmable and can be adjusted in [ms].

  • 7/25/2019 GAA 24350 AW11 II.pdf