G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti

G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti

  • View
    224

  • Download
    4

Embed Size (px)

Citation preview

Page 1: G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti

G4N

AM

U GEANT4North America Medical Users Organization

(G4NAMU)

GEANT4 in external beam therapyHarald Paganetti

Page 2: G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti

G4N

AM

U TOPIC I:Beamline design and quality assurance

Page 3: G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti

G4N

AM

U TOPIC II:Magnetic fields

Page 4: G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti

G4N

AM

U TOPIC III:Absolute dosimetry

MUcGy

iFactorOutput

ic

calD

dFdp

dx

dE

W

ei

airair

icic

Volume for absolute dosimetry

Energy deposited / step / Wair

1 10

Par

ticl

es [

rel.

un

its]

0

20

40

60

80

100

120R=22 ; M=8

R=20 ; M=12

R=15.5 ; M=7.5

R=15.5 ; M=12

R=12 ; M=2.5

R=12 ; M=6

R=8.5 ; M=3.5

R=12 ; M=9.5

R=8.5 ; M=7.5

Page 5: G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti

G4N

AM

U TOPIC IV:Patient dose calculation

FOCUS

FOCUS Monte Carlo

Monte Carlo

Page 6: G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti

G4N

AM

U TOPIC V:Time dependent simulations

Solid lines: Patient in inhaleDashed lines: Considering the entire breathing phase

Page 7: G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti

G4N

AM

U TOPIC VI:Radiation Protection

Page 8: G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti

G4N

AM

U TOPIC VII:Radiation Risk

Red bone marrow

0.00001

0.0001

0.001

0.01

0.1

1

0 20 40 60 80Dose (Gy)

Fra

ctio

n vo

lum

e

LP RP

LA

© X. George Xu, RPI

© X. George Xu, RPI

Page 9: G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti

G4N

AM

U TOPIC VIII:Detector Simulation

Page 10: G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti

G4N

AM

U GEANT4 users in external beam radiation therapyin North America:

Issues:

• Correct and reliable physics lists

• Physics wish list for upcoming new G4 versions

• Tracking wish list for upcoming new G4 versions

• CT-formats (DICOM etc)

• Accuracy as a function of level of detail

• Benchmarking data set (exp, theo)

• G4NAMU and other Monte Carlo groups

• Teaching course

Page 11: G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti

G4N

AM

U

• Correct and reliable physics lists

Protons: send e-mail to [email protected]

Page 12: G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti

Possible problem in the elastic multiple scattering algorithm© J

oao

Sec

oR

oyal

Mar

sden

, Lon

don

, UK

Page 13: G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti

Issues related to dose calculations on CT data

• Memory consumption for storing CT data• Conversion of CT Hounsfield units

G4N

AM

U

Page 14: G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti

DICOM

http://bromley.phy.ulaval.ca/phys_med/DICOM/index.html

G4N

AM

U

Page 15: G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti

0

2

4

6

8

10

12

14

16

18

1.5E-04 1.7E-04 1.9E-04 2.1E-04 2.3E-04 2.5E-04 2.7E-04 2.9E-04

Dose (Gy/300 m illion protons)

Vo

lum

e(%

)

50,000,000 protons per f ield

100,000,000 protons per f ield

240,000,000 protons per f ield

G4N

AM

U

Page 16: G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti

Neutron energy distributions for 150 MeV protons incident on a 1cm water slab

© W

ang

and

Pag

anet

tiR

PI,

New

Yor

k;

MG

H, B

osto

n

Page 17: G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti

G4N

AM

U Role of G4NAMU with respect to other groups :

Computational Medical Physics Working Group (CMPWG)American Nuclear Society (ANS)

Mathematics and Computations (M&C)Biology and Medicine (BMD)Radiation Protection and Shielding (RPSD)

Bernadette Kirk

AAPMTask Group 105: “Monte Carlo in Clinical Treatment Planning“

Bruce Curran and Indrin Chetty