5
F Y R E H A L T V FYREHALT V FIRE+SMOKE CURTAIN Designed and engineered in Australia, the Fyrehalt V fire shutter has the smallest headbox size, consists of a single overhead coil fire curtain, with no overlap. This unique and compact design allows the Fyrehalt V to be easily integrated into both existing and new buildings, maximising the use of internal spaces in offices, shopping centres, multistorey apartments, hospitals and warehouses. Fyrehalt V fire curtains/shutters are exported from our Australian factory to many high-profile projects around the world. l Independent Third Party Verified for compliance with fire test approvals l Fire tested in accordance with AS1530.4:2014 l Fire Ratings up to -/120/- l Tested in accordance with AS1530.7 for smoke containment l Compact Headbox l Gravity Fail Safe l Automatic rewind l Light weight l Highly reliable single over- head coil (no overlaps) l Ideal for small to medium size openings AS1530.7 74m3/hour AS1530.4 –/120/– AS1530.4 12.57kW/m2

FYREHALT V - Smoke Control

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: FYREHALT V - Smoke Control

FY

RE

HA

LT

V FYREHALT

VFIRE+SMOKE CURTAIN

Designed and engineered in Australia, the Fyrehalt V fire shutter has the smallest headbox size, consists of a single overhead coil fire curtain, with no overlap.

This unique and compact design allows the Fyrehalt V to be easily integrated into both existing and new buildings, maximising the use of internal spaces in offices, shopping centres, multistorey apartments, hospitals and warehouses.

Fyrehalt V fire curtains/shutters are exported from our Australian factory to many high-profile projects around the world.

l Independent Third Party Verified for compliance with fire test approvals

l Fire tested in accordance with AS1530.4:2014

l Fire Ratings up to -/120/-

l Tested in accordance with AS1530.7 for smoke containment

l Compact Headbox

l Gravity Fail Safe

l Automatic rewind

l Light weight

l Highly reliable single over- head coil (no overlaps)

l Ideal for small to medium size openings

AS1530.7

74m3/hour

AS1530.4

–/120/–

AS1530.4

12.57kW/m2

Page 2: FYREHALT V - Smoke Control

FYREHALT V Fire+Smoke Curtain

FY

RE

HA

LT

V

2

I INTRODUCTIONFyrehalt V fire curtains/shutters are uniquely Australian made in our own ISO9001 accredited facility using only high-quality components.

The system consists of a head box, curtain barrel, side guides and bottom bar. With a compact head box size of just 165mm x 165mm the Fyrehalt V fire curtain is capable of spanning 8m without overlaps and multiple modules, significantly increasing the reliability of the system compared to overlapped systems.

I COMPLIANCEFyrehalt V can be supplied, installed and certified for fire ratings up to -/120/- in accordance with AS1905.2 Fire Shutters and AS1530.4 Fire Test Methods. The system has also been tested in accordance with AS1530.7 Air (Smoke) Leakage as a smoke containment screen.

Fyrehalt V also bears the Warnock Hersey Mark (WH). The Warnock Hersey Mark (WH) signifies that our manufacturing sites undergo periodic and independent 3rd party inspections to ensure ongoing compliance with fire test approvals. The WH Mark is the world’s largest product compliance scheme and provides our customers with total surety by eliminating product and component substitution.

Smoke Control is one of the few manufacturers and suppliers of Fire & Smoke curtains whose products have been accredited under this scheme outside of the USA, providing many customers around the world, total assurance in our company and products.

TARGET PERFORMANCE DATA RESULTS

FIRE PROTECTION

Fire Shutter Complies with AS1905.2:2005

Fire Rating -/120/- in accordance with A51530.4

Radiant Heat1 <12.57 kW/m2 @ 500mm and 30 minutes into the Standard Fire Test (ISO834/AS1530.4)

Smoke Performance <74m3/hour when full system is tested in accordance with AS1530.7 (3.3 x 3.3m tested system)

SMOKE PROTECTION

Spread of Flame 0, 0, 0, 2 when tested in accordance with AS1530.3:1999

Group Number Group 1 when tested in accordance with AS3837

Cycle Test Greater than 30,000 open-close cycles

FUNCTIONALITY

Operating Speed 150mm/s nominally

Maximum Pressure Differential 23Pa when fully closed

System Weight 20 to 25kg per/m of width depending on system height

Maximum Sizes 8m max width, 4m max height

What you need to knowFor larger spans with a single overhead coil up to 30m wide, please refer to our light weight Fibershield V fire shutter system.

Page 3: FYREHALT V - Smoke Control

FYREHALT V Fire+Smoke Curtain

FY

RE

HA

LT

V

3

I FUNCTION

SYSTEM OPERATIONThe system is typically held in the open position during normal building use. Upon receipt of an alarm or loss of power, Fyrehalt V fire shutters deploy to provide Fire & Smoke compartmentation. On reset of the Fire Indicator Panel (FIP or power), the system automatically rewinds back into the standby position.

The control box is a compact 290 x 240 x 110mm box requiring a standard 240V, 10A power supply and an alarm signal in the form of a normally closed, dry contact. A localised smoke or heat detector may also be used to activate the system. Please contact our technical department for details on 1300 665 471.

EGRESSWhen Fyrehalt V fire shutters are used as part of egress strategy, rewind switches can be connected directly to the standard control box. Switches can be mounted on one or both sides of the wall. Once pressed the system will retract and then redeploy. The rewind system is supplied standard with a battery backup for operation during mains power failure. In some applications, such as basement carparks, it may be necessary to provide a fire door immediately adjacent to the fire curtain shown below.

INSTALLATIONIn line with Smoke Control’s mission to provide customers with reliable solutions, the Fyrehalt V system is installed by our fully trained and approved installer network.

MAINTENANCEAs with all essential services, Fyrehalt V should be maintained in strict accordance with our documented procedures by fully trained and competent technicians. Operational tests alone are not considered adequate and when conducted by inexperienced personnel, may lead to damage of the product. Smoke Control offers a comprehensive preventative maintenance program which has proven costs savings over the life of the product.

Please contact our maintenance department for details on 1300 665 471.

| Fire and smoke compartmentation in a basement carpark with additional egress door. An egress door prevents occupants from driving out of the car park and blocking fire fighting activities

Page 4: FYREHALT V - Smoke Control

FYREHALT V Fire+Smoke Curtain

FY

RE

HA

LT

V

4

WE

BE

LIE

VE

PE

OP

LE

DE

SE

RV

E T

O W

OR

K &

LIV

E IN

SA

FE

& B

EA

UT

IFU

L B

UIL

DIN

GS

I APPLICATIONSIdeal for small to medium openings, Fyrehalt V have been used to provide Fire & Smoke compartmentation in:

l hospitals

l basement carparks

l lift shafts

l warehouse dividing walls

l interconnecting stairs

l servery openings

l universities

PRODUCT DIMENSIONS| Typical head box section

| Hospital Fire & Smoke Compartmentation

| Aged Care Fire & Smoke Compartmentation

| University Fire & Smoke Compartmentation

| Typical side guide section

ACCESSORIES l bottom bar cover

l battery backup

l rewind switches

l curtain applied signage

FILE: SCS-FH.dwg --- PLOTTED ON 04/09/2020 BY ISHTIAQUE ALAM

· THIS DRAWING IS COPYRIGHT AND THE PROPERTY OF THE AUTHOR, AND MUST NOT BERETAINED, COPIED OR USED WITHOUT THE AUTHORITY OF SMOKE CONTROL SYSTEMSPTY. LTD.

· DO NOT SCALE FROM DRAWING, USE PROVIDED DIMENSIONS ONLY.· ALL DISCREPENCIES MUST BE BROUGHT TO THE ATTENTION OF AUTHOR.· SMOKE CONTROL SYSTEMS DO NOT TAKE RESPONSIBILITY OF MEASUREMENTS

PROVIDED BY OTHERS.

Rev CHK REASON DATE

CLIENT

AUSTRALIAN HEADOFFICEPHONE: 1300 665 [email protected]

NEW ZEALANDPHONE: 09 300 [email protected]

WWW.SMOKECONTROL.COM.AU

DRAWN BY

START DATE

DRAWING NUMBER

ISSUE STATUS:

TITLE

PROJECT

<<< 594mm

420m

m >>

>

SCALE@A2

SUB SET (CATEGORY)

INFORMATIONC O P Y O N L Y

INFORMATION GIVEN IN SMOKECONTROL.COM.AU AND PUBLICATIONS FORDOWNLOAD ARE GIVEN TO THE BEST OF OUR KNOWLEDGE AND IN GOODFAITH. SMOKE CONTROL IS NOT RESPONSIBLE IF RECIPIENTS OF TESTREPORTS, ASSESSMENTS OR LITERATURE MISINTERPRET THE CONTENTSAND WRONGLY USE PRODUCTS BASED ON THOSE MISINTERPRETATIONS. NOLIABILITY IS ACCEPTED FOR ERROR OMISSIONS IN THIS WEB SITE OR OURDOCUMENTS. IN THE INTERESTS OF IMPROVEMENTS AND CONTINUEDDEVELOPMENT SMOKE CONTROL RESERVES THE RIGHT TO CHANGESPECIFICATION WITHOUT NOTICE.

DISCLAIMER

WWW.SMOKECONTROL.CO.NZWWW.SMOKECONTROL.COM

REV

SCS-FH

HEAD BOX INSTALLATION TYPES

SCS-FH-0201I.A. INFORMATION ONLY

24/08/2020 AS SHOWN

FYREHALT FIRE CURTAIN

02 - DETAILS

-

1SIDE ELEVATIONSOFIT FIXING DETAILSCALE 1:5 @ A2

165

48 67 50

BULK

HEAD

165

100 M

IN

STOPPER BRACKETFIXED TO SIDE GUIDE

FIRE RATEDBULKHEAD BYOTHERS

2/ 10g SCREWS ORM8 DYNABOLTS @1500 MAX. CTS.

450x450 ACCESSPANEL BY OTHERSLOCATED AT THENOMINATE LOCATION OFCURTAIN CONTROLLER

FIXING STRUCTURE REQUIREDAT APPROPRIATE LOCATIONTO SUPPORT 25Kg/LINEALMETRE OF CURTAIN WIDTH

165

BULK

HEAD

5075

40

165

FIRE RATEDBULKHEAD BYOTHERS

FIXING STRUCTURE REQUIREDAT APPROPRIATE LOCATIONTO SUPPORT 25Kg/LINEALMETRE OF CURTAIN WIDTH

2/ 10g SCREWS ORM8 DYNABOLTS @1500 MAX. CTS.

2SIDE ELEVATIONFACE FIXING DETAILSCALE 1:5 @ A2

48 67 50

165

165

2/ Ø8 DYNABOLTS@ 1500 MAX. CTS.

4SIDE ELEVATIONFIXED TO SLABSCALE 1:5 @ A2

STOPPER BRACKETFIXED TO SIDE GUIDE

TRIM ANGLE BY OTHERS

3

25 50 CEILING GAP 25

100

OPTIONAL 100X3 THICK ALUMINIUMBOTTOM BAR COVER FINISHED TOARCHITECTS SPECIFICATIONS

5ELEVATIONOPTIONAL LEVELING BOTTOMBARSCALE 1:2 @ A2

3SIDE ELEVATIONSOFIT FIXING TO BEAM DETAILSCALE 1:5 @ A2

2/ SERIES 500STRUCTURALTEK SCREWS @1500 MAX. CTS.

MAX STEEL THICKNESS 12mmOTHERWISE ADDITIONAL FIXINGSTRUCTURE MUST BE ADDED.

- AC RELEASED 04/09/2020

FILE: SCS-FH.dwg --- PLOTTED ON 04/09/2020 BY ISHTIAQUE ALAM

· THIS DRAWING IS COPYRIGHT AND THE PROPERTY OF THE AUTHOR, AND MUST NOT BERETAINED, COPIED OR USED WITHOUT THE AUTHORITY OF SMOKE CONTROL SYSTEMSPTY. LTD.

· DO NOT SCALE FROM DRAWING, USE PROVIDED DIMENSIONS ONLY.· ALL DISCREPENCIES MUST BE BROUGHT TO THE ATTENTION OF AUTHOR.· SMOKE CONTROL SYSTEMS DO NOT TAKE RESPONSIBILITY OF MEASUREMENTS

PROVIDED BY OTHERS.

Rev CHK REASON DATE

CLIENT

AUSTRALIAN HEADOFFICEPHONE: 1300 665 [email protected]

NEW ZEALANDPHONE: 09 300 [email protected]

WWW.SMOKECONTROL.COM.AU

DRAWN BY

START DATE

DRAWING NUMBER

ISSUE STATUS:

TITLE

PROJECT

<<< 594mm

420m

m >>

>

SCALE@A2

SUB SET (CATEGORY)

INFORMATIONC O P Y O N L Y

INFORMATION GIVEN IN SMOKECONTROL.COM.AU AND PUBLICATIONS FORDOWNLOAD ARE GIVEN TO THE BEST OF OUR KNOWLEDGE AND IN GOODFAITH. SMOKE CONTROL IS NOT RESPONSIBLE IF RECIPIENTS OF TESTREPORTS, ASSESSMENTS OR LITERATURE MISINTERPRET THE CONTENTSAND WRONGLY USE PRODUCTS BASED ON THOSE MISINTERPRETATIONS. NOLIABILITY IS ACCEPTED FOR ERROR OMISSIONS IN THIS WEB SITE OR OURDOCUMENTS. IN THE INTERESTS OF IMPROVEMENTS AND CONTINUEDDEVELOPMENT SMOKE CONTROL RESERVES THE RIGHT TO CHANGESPECIFICATION WITHOUT NOTICE.

DISCLAIMER

WWW.SMOKECONTROL.CO.NZWWW.SMOKECONTROL.COM

REV

SCS-FH

SIDE GUIDE INSTALLATION TYPES

SCS-FH-0202I.A. INFORMATION ONLY

24/08/2020 AS SHOWN

FYREHALT FIRE CURTAIN

02 - DETAILS

-

1PLANTOE FIXED SIDE GUIDESCALE 1:2 @ A2

2PLANREBETED SIDE GUIDESCALE 1:2 @ A2

3PLANFACE FIXED SIDE GUIDESCALE 1:5 @ A2

4PLAN90° POST DETAILSCALE 1:5 @ A2

10 100

12g SCREWS ORØ8 DYNABOLTS @1000 MAX. CTS.

SEALANT & PACKING

SIDE GUIDEBOTTOM BAR

165

5036

10 100

12g SCREWS ORØ8 DYNABOLTS@ 1000 MAX CTS.

SEALANT & PACKING

SIDE GUIDE

BOTTOM BAR

WALL MAY NEED TO BEREBATED TO ALLOW FORFITMENT OF HEAD BOX. SEESHEET 0203 FO R DETAILS.

APPROPRIATEFIXING STRUCTURE

12g SCREWS ORØ8 DYNABOLTS @1000 MAX. CTS.

ARCHITECTURALCLADDING BY OTHERS

6733

100

APPROPRIATEFIXING STRUCTURE

165100

FRL -/120/120 FIRE RATEDSTRUCTURAL POST BY OTHERS

POST FIXED TO STRUCTURETOP & BOTTOM

ARCHITECTURALCLADDING BY OTHERS

12g SCREWS @ 1000 MAX. CTS.

50

100

165

50

- AC RELEASED 04/09/2020

FYREHALT V Fire+Smoke Curtain

Page 5: FYREHALT V - Smoke Control

Australia1300 665 471

International+61 2 96814000

New Zealand +64 9 300 1980

| 1300 665 471 | [email protected] | www.smokecontrol.com.au

We believe people deserve to work & livein safe & beautiful buildings

I TECHNICAL SUPPORTSmoke Control offers obligation free technical support and pricing throughout your design and documentation stage so you can accurately prepare your budgets through value engineering.

You can also download the set of specifications, drawings and technical data from our website www.smokecontrol.com.au.

Contact our technical department to discuss your project requirements, or feel free to arrange a meeting.

A LITTLE MORE ABOUT US...Smoke Control was established in 2003. We partner with leading local and international organisations to work with the new performance-based design environment - in addition to the traditional prescriptive environment - designing and installing systems to meet the challenging Fire & Smoke control demands of modern buildings.

Constant research and development continue to enhance our offering of fire windows, fire shutters and Fire & Smoke curtains, bringing the most innovative technology to both regular and unique project challenges. If you cannot find what you are looking for, please contact our team as we may already have a solution for you.

Smoke Control services all regions in Australia and New Zealand via our own offices and people. International customers can contact our Australian office by phone or email for your nearest distributor.

GENERAL INFORMATION