    Device/PLC Connection

    Abou t the Devic e/PLC Connect ion Manuals

    Prior to reading these manuals and setting up your device, be sure to read the"Important: Prior to reading the Device/PLC Connection manual" information. Also,be sure to download the "Preface for Trademark Rights, List of Units Supported, Howto Read Manuals and Documentation Conventions" PDF file. Furthermore, be sureto keep all manual-related data in a safe, easy-to-find location.

    Manuals

  • 8/12/2019 Fuji PLC Conection 1

    2/13

    Chapter 2 - PLC-GP Connection

    2-3-1

    2.3 Fuji Electric

    GP-PRO/PBIII for Windows Device/PLC Connection Manual

    CPU Link I/F Cable Diagram Cables GP

    PC

    I/F Module/Generic I/F

    F80H, F120H,F250

    FFU-120BPC Interface Module

    RS-232C(Cable Diagram 1)

    RS-422(Cable Diagram 2)

    RS-232CDigital's GP410-IS00-O (5m)

    F70S (NC1P-S0) NC1L-RS2 (Generic

    Interface)*1

    RS-232C(Cable Diagram 1)

    Digital's GP410-IS00-O (5m)

    GP Series

    2.3 Fuji Electric

    2.3.1 System Structure

    R e f e r e n c e

    The following describes the system structure for connecting the GP to FujiElectric Corporation, Ltd. PLCs.

    Cable Diagrams mentioned in the following tables are listed in the section titled " 2.3.2 Cable Diagrams ".

    In the LS area, 32-bit devic es are not s upp orted . Therefore, wh en System A rea address es are allocated to B D, DL, or W33 devices,only System Area (LS0 to LS19) address es can be used . Other LS areas, such as the user area, etc. sho uld n ot be us ed.

    MICREX-F Series (using Link I/F)

    !!!!!Important

    *1 When expansion units are attached via a T-Link system to a main PLC unit,

    and more than 2 link units are attached to the expansion unit, the GP unit canbe attached to only one of the link units. (Simultaneous connection to 2 link units is not possible.)

    Simultaneous connection to 2 link units is possible only when they are at-tached to the main PLC unit.

  • 8/12/2019 Fuji PLC Conection 1

    3/13

    Chapter 2 - PLC-GP Connection

    2-3-2

    2.3 Fuji Electric

    GP-PRO/PBIII for Windows Device/PLC Connection Manual

    CPU Link I/F Cable Diagram Cables GP

    GeneralSIO Unit/

    GeneralI/F Module

    NB1, NB2, NB3 NB-RS1-AC(Generic RS-232C/485 SIO unit)

    RS-232C(Cable Diagram 1)

    RS-422

    (Cable Diagram 2)

    RS-232CDigital's GP410-IS00-O (5m)

    NJ-RS2 (Generic RS-232C SIO interfacemodule)

    RS-232C(Cable Diagram 1)

    Digital's GP410-IS00-O (5m)

    NJ-RS2 (Generic RS-485 SIO interfacemodule)

    RS-422(Cable Diagram 2)

    NS NS-RS1 (Generic RS-232C/485 interfacemodule)

    RS-232C(Cable Diagram 1)

    RS-422

    (Cable Diagram 2)

    RS-232CDigital's GP410-IS00-O (5m)

    NJ

    GP Series

    CPU Adapter Cable Diagram Cables GPPC Loader adapter

    F80H, F250,F120H

    Fuji Electric's FLT-ASFK RS-232C(Cable Diagram 1)

    RS-232CDigital's GP410-IS00-O

    GP Series

    Note:Note:Note:Note:Note: Places noted as RS-422 can also use RS-485 on the PLC side.

    MICREX-F Series (FLT-ASFK) (CPU Direct Connection)

    FLEX-PC Series (using Link I/F)

    CPU Link I/F Cable Diagram Cables GP

    PC

    InterfaceModule

    FFK120A-C10 RS-232C(Cable Diagram 1)

    RS-422(Cable Diagram 2)

    RS-232CDigital's GP410-IS00-O (5m)

    FFK100A-C10 RS-232C(Cable Diagram 3)

    GP Series

    F80H, F120H,F250F30, F50, F60,F80, F81, F120F120S, F200

    MICREX-F Series (using Link I/F)

  • 8/12/2019 Fuji PLC Conection 1

    4/13

    Chapter 2 - PLC-GP Connection

    2-3-3

    2.3 Fuji Electric

    GP-PRO/PBIII for Windows Device/PLC Connection Manual

    CPU Cable Diagram GP

    NB1, NB2, NB3, NJ,NS

    RS-422(Cable Diagram 4)

    GP Series

    FLEX-PC Series (CPU Direct Connection)

    When using Digital's T-Link I/F Unit, refer to the GP-*50/70 Series T-Link I/FUnit User's Manual.

    Note:Note:Note:Note:Note:

  • 8/12/2019 Fuji PLC Conection 1

    5/13

    Chapter 2 - PLC-GP Connection

    2-3-4

    2.3 Fuji Electric

    GP-PRO/PBIII for Windows Device/PLC Connection Manual

    2.3.2 Cable Diagrams

    !!!!!Important

    Ca r e f u l!

    Ca r e f u l !

    The cable diagrams illustrated below and the cable diagrams recommended by Fuji Electric Co., Ltd. may differ; in any case, using these cables for your PLC operations will not cause any problems.

    Ground your PLC's FG terminal according to your country's appli-cable standard. For details, refer to the corresponding PLC manual.

    Conn ect the FG line of the Shield cable to either the GP or PLC,depending on your environment . When using a connector hood

    and grou nding the FG l ine, be sure to use an electr ical condu c- tor.

    For the RS-232C conn ection, use a cable length less th an 15m.

    If a comm unicat ions cable is used, i t must be conn ected to the SG (signal ground ).

    Cable Diagram 1 (RS-232C)

    When using Digital's RS-422 connector terminal adapter GP070-CN10-0

    Turn on the Termination Resistor switch, on the PLC side.

    Cable Diagram 2 (RS-422)

    NC

  • 8/12/2019 Fuji PLC Conection 1

    6/13

    Chapter 2 - PLC-GP Connection

    2-3-5

    2.3 Fuji Electric

    GP-PRO/PBIII for Windows Device/PLC Connection Manual

    Note:Note:Note:Note:Note:

    When using Digital's RS-422 Cable, GP230-IS11-0

    When making your own cable connections

    When making your own cable connections, we recommend using HitachiDensen's CO-SPEV-SB(A)3P*0.5S cable.

    When connecting the #9 and #10 pins in the GP Serial I/F, a termination resis-tance of 100 is added between RDA and RDB.

    Cable Diagram 3 (RS-232C)

    A4 ER A6 CIB1 FGB2 SDB3 RDB4 RSB5 CS

    B6 DRB7 SGB8 CD

    PLC

    RDA

    RDB

    SDA

    SDB

    SDA

    SDB

    RDA

    RDB

    S

    NC

    CD

  • 8/12/2019 Fuji PLC Conection 1

    7/13

    Chapter 2 - PLC-GP Connection

    2-3-6

    2.3 Fuji Electric

    GP-PRO/PBIII for Windows Device/PLC Connection Manual

    Note:Note:Note:Note:Note:

    Cable Diagram 4 (RS-422)

    For the PLC side connector (modular-jack) you can use Hirose's TM11P-88P.

    The pin numbers of the modular-jack for the connec-tion diagrams below are based on the order describedin the figure at the left.

    When using Digital's RS-422 connector terminal adapter GP070-CN10-0

    When using Digital's RS-422 Cable, GP230-IS11-0

    When making your own cable connections

    When connecting the #9 and #10 pins in the GP Serial I/F, a termination resis-tance of 100 is added between RDA and RDB.Note:Note:Note:Note:Note:

  • 8/12/2019 Fuji PLC Conection 1

    8/13

    Chapter 2 - PLC-GP Connection

    2-3-7

    2.3 Fuji Electric

    GP-PRO/PBIII for Windows Device/PLC Connection Manual

    2.3.3 Supported Devices

    Setup System Area here.

    (See next page)

    The following describes the range of devices supported by the GP.

    MICREX-F Series

    * 1 The MSB (most significant bit) of a word device corresponds to bit 0 of the device,and the LSB (least significant bit) corresponds to bit F .

    E.g. When hexadecimal data 0001 is written to a Word device address

    Device Bit Address Word Address

    I/O Relay B0000 ~ B511F WB0000 ~ WB0511 *1

    Direct I/O --- W24.0000 ~ W24.0159

    Auxilary Relay M0000 ~ M511F WM0000 ~ WM0511 *1

    Keep Relay K0000 ~ K063F WK000 ~ WK063 *1

    Differential Relay D0000 ~ D063F WD000 ~ WD063 *1 *4

    Link Relay L0000 ~ L511F WL000 ~ WL0511 *1

    Special Relay F00000 ~ F4095F WF0000 ~ WF4095 *1 *4

    Announce Relay A00000 ~ A4095F WA0000 ~ WA4095 *1 *4

    Timer 0.01 sec T0000 ~ T0511 ---

    Timer 0.1 sec T0512 ~ T1023 ---

    Counter C0000 ~ C0255 ---

    Timer 0.01 sec(current value)

    --- TR0000 ~ TR0511

    Timer 0.01 sec(setup value)

    --- TS0000 ~ TS0511

    Timer 0.1 sec(current value)

    --- W9.000 ~ W9.511

    Counter (current value) --- CR0000 ~ CR0255

    Counter (setup value) --- CS0000 ~ CS0255

    --- BD0000 ~ BD4095

    --- DI0000 ~ DI4095

    --- SI0000 ~ SI4095

    --- W30.0000 ~ W30.4094 *2

    --- W31.0000 ~ W31.4094 *2

    --- W32.0000 ~ W32.4094 *2

    --- W33.0000 ~ W33.4094 *3

    --- W34.0000 ~ W34.4094 *3

    Particulars

    Data Memory

    File Memory

    H/L

  • 8/12/2019 Fuji PLC Conection 1

    9/13

    Chapter 2 - PLC-GP Connection

    2-3-8

    2.3 Fuji Electric

    GP-PRO/PBIII for Windows Device/PLC Connection Manual

    * 2 Define and use 16 bit length data.

    * 3 Define and use 32 bit length data.

    * 4 This device cannot write. Use it only for reading.

    !!!!!Important

    In the LS area, 32-bit devic es are no t sup por ted. Therefore, wh en System A rea addr esses are allocated to B D, DL, or W33 devices,only System A rea (LS0 to LS19) addresses can b e used. Other LS areas, such as the user area, etc. should not b e used.

    When u sing the GP-570VM or GP-870VM, do not allocate the Sys- tem Ar ea for B D, DI, or W33 wo rd address es.

    Certain PLC mod els and version s may no t be able to perform bit reading or wri t ing .

    F30 .. .... .... not poss ible with versions 0.9 or lower F50 .. .... .... not poss ible with versions 1.4 or lower F50H ..... .. not po ssible with version s 0.7 or lower F80 .. .... ... . not poss ible with any version F81 .. .... ... . not poss ible with any version F120 . .... ... not po ssible with any version F200 . .... ... not po ssible with any version

    Check the informat ion p la te on the s ide of the PLC to f ind the PLCs version inform ation.

    When processing 16-bit single word data:

    Internally, the GP basically processes 1 word as 16 bit length data. As a result,the reading and writing of 32 bit length data devices are processed as follows:

    Reading From 32 bit data, reads data only from the bottom16 bits.

    Writing From 32 bit data, writes data only to the bottom16 bits, as 0 is written to the top 16 bits.

    E.g. When data is 12345678 hex.

    When processing 2 word 32-bit data:

    Two word addresses at bit length 16 are necessary to handle 32 bit long data, but when using a 32 bit device, only one word address needs to be specified.

    (from previous page)

  • 8/12/2019 Fuji PLC Conection 1

    10/13

    Chapter 2 - PLC-GP Connection

    2-3-9

    2.3 Fuji Electric

    GP-PRO/PBIII for Windows Device/PLC Connection Manual

    Setup System Area here.

    When using a 16 bit device

    When using a 32 bit device

    FLEX-PC Series

    Cannot read the Timer and Counter setup value. However, the write opera-tion is possible only when the PLC is in program mode.

    * 1 Define and use 16 bit length data.

    Note:Note:Note:Note:Note:

    Device Bit Address Word Address

    Input Relay X0000 ~ X07FF WX0000 ~ WX07F

    Output Relay Y0000 ~ Y07FF WY0000 ~ WY07F

    Intemal Relay M0000 ~ M03FF WM000 ~ WM03F

    Extended Intemal Relay M0400 ~ M1FFF WM040 ~ WM1FF

    Latch Relay L0000 ~ L03FF WL000 ~ WL03F

    Extended Latch Relay L0400 ~ L1FFF WL040 ~ WL1FF

    Special Relay M8000 ~ M81 FF WM800 ~ WM81FTimer T0000 ~ T03FF ---

    Counter C0000 ~ C01FF ---

    Timer (current value) --- T0000 ~ T03FF

    Timer (setup value) --- TS0000 ~ TS03FF *1

    Counter (current value) --- C0000 ~ C01FF

    Counter (setup value) --- CS0000 ~ CS01FF *1

    Data Register --- D0000 - D2FFF

    Special Register --- D8000 ~ D837F

    Link Register --- W0000 ~ W3FFF

    File Register --- R0000 ~ R7EFF

    Particulars

    L/H

  • 8/12/2019 Fuji PLC Conection 1

    11/13

    Chapter 2 - PLC-GP Connection

    2-3-10

    2.3 Fuji Electric

    GP-PRO/PBIII for Windows Device/PLC Connection Manual

    When the Timer and Counter setup values are written from the GP, the ladderis changed so that the setup value uses a relative reference. For this reason,be careful when the setup value for the Timer and Counter uses an indirectladder. Normally, access is recommended for indirectly referenced devices.

    2.3.4 Environment Setup

    The following tables list Digital's recommended PLC and GP communicationsettings.

    MICREX-F Series (using PC I/F module FFU120B)

    MICREX-F Series (using General Interface Module NC1L-RS2)

    Baud Rate 19200 bps Baud Rate 19200 bps

    Data Length 7 bits Data Length 7 bitsStop Bit 2 bits Stop Bit 2 bits

    Parity Bit Even Parity Bit Even

    Data Flow Control ER Control Transfer Condition DTR on/ CTS on

    Communication Format(RS-232C)

    RS-232C MODE Switch(RS-232C)

    1

    Communication Format( RS-422)

    4-wire type MODE Switch(RS-422)

    3

    Char. structure Switch 8 (lNlT) is Off

    RS-485 Station # setup Switch

    (Oniy for RS-485) 0

    Unit No. 0 (fixed) ---

    FFU120B Setup

    ---

    ---

    GP Setup

    Baud Rate 19200 bps Baud Rate 19200 bps

    Data Length 8 bits Data Bit 8 bits

    Stop Bit 1 bit Stop Bit 1 bit

    Parlty Bit None Parity Bit None

    Data Flow Control ER Control Transfer Condition DTR on/CTS on

    Communication Format RS-232C MODE Setup 1

    Character Structure Switch8 (Initialize SetupProcess) is Off (Initial file)

    Unit No. 0 (fixed)

    ---

    ---

    GP Setup NC1L-RS2 Setup

    Setup this data in Fi le Def in i t io n . Communication isnot possible when using a Link I/F switch.

    Setup this data in Fi le Def in i t io n . Communication isnot possible when using a Link I/F switch.

    !!!!!Important

    !!!!!Important

  • 8/12/2019 Fuji PLC Conection 1

    12/13

    Chapter 2 - PLC-GP Connection

    2-3-11

    2.3 Fuji Electric

    GP-PRO/PBIII for Windows Device/PLC Connection Manual

    MICREX-F Series (using PC I/F capsule FFK120A-C10)

    Baud Rate 19200 bps Baud Rate 19200 bps

    Data Length 7 bits Data Length 7 bits

    Stop Bit 2 bits Stop Bit 2 bits

    Parity Bit Even Parity Bit Even

    Data Flow Control ER Control Transfer Condition None

    Communication Format(RS-232C)

    RS-232CMODE Switch(RS-232C)

    1

    Communication Format(RS-422)

    4-wire typeMODE Switch(RS-422)

    3

    RS-485 Station # setup Switch(Only when using RS-485)

    0

    Unit No. 0 (fixed)

    ---

    ---

    FFK120A-C10 SetupGP Setup

    Setup this data in Fi le Def in i t io n . Communication isnot possible when using a Link I/F switch.

    MICREX-F Series (using PC I/F capsule FFK100A-C10)

    Setup this data in Fi le Def in i t io n . Communication isnot possible when using a Link I/F switch.

    Baud Rate 19200 bps Baud Rate 19200 bps

    Data Length 7 bits Data Length 7 bits

    Stop Bit 2 bits Stop Bit 2 bits

    Parity Bit Even Parity Bit Even

    Data Flow Control ER Control

    Communication Format(When using RS-232C)

    RS-232C

    Unit No. 0 (fixed)

    PK access PermittedCode conversion Available

    ---

    ---

    ---

    FFK100A-C10 SetupGP Setup

    ---

    !!!!!Important

    !!!!!Important

  • 8/12/2019 Fuji PLC Conection 1

    13/13

    Chapter 2 - PLC-GP Connection

    2-3-12

    2.3 Fuji Electric

    GP-PRO/PBIII for Windows Device/PLC Connection Manual

    FLEX-PC Series (using Link I/F)

    FLEX-PC Series (using CPU Direct Connection)

    MICREX-F Series (FLT-ASFK)

    Baud Rate 19200 bps Baud Rate 19200 bps

    Data Length 8 bits Data Length 8 bits

    Stop Bit 1 bit

    Parity Bit None Parity BitON/OFFEVEN/ODD

    OFFNone

    Data Flow Control ER Control

    Communication Format RS-232C

    Unit No. 0

    MODE LOADER

    Adapter SetupGP Setup

    ---

    ---

    ---

    ---

    ---

    Baud Rate 19200 bps Baud Rate 19200 bps

    Data Length 7 bits Data Length 7 bits

    Stop Bit 1 bit Stop Bit 1 bit

    Parity Bit Even Parity Bit Even

    Data Flow Control ER Control Transfer Condition DTR on/ CTS onCommunication Format(RS-232C)

    RS-232C MODE Switch(RS-232C)

    1

    Communication Format(RS-422)

    4-wire type MODE Switch(RS-422)

    3

    Unit No. 1 Station No. 1

    Communication Unit / lnterface Module SetupGP Setup

    PLC side Setup

    Baud Rate 19200 bps(fixed) ---

    Data Length 8 bits (fixed) ---

    Stop Bit 1 bit (fixed) ---

    Parity Bit Odd (fixed) ---

    Data Flow Control ER Control (fixed) ---

    Communication Format 4-wire type (fixed) ---

    Unit No. 1 (fixed) ---

    GP Setup