MechanicalMaintenanceDepartmentElectricityGenera2ngAuthorityofThailand
4Moo.6BangpakongPowerPlant,ThaKam,Bangpakong,Chachoengsao,Thailand
FUELOILDIFFUSIONSYSTEMCLEANINGFORGASTURBINE(MODEL:SIEMENSV94.3A)
IssaraPongsawanParinyaPanyananAdisornSrimoonTarmjaiJi4rakij
EGATElectricityGenera2ngAuthorityofThailand
-CompanyBackground-
Maintainability !
Efficiency !
Availability !
Reliability !
2 !
BANGPAKONGCOMBINEDCYCLEBLOCK5(BC5)
3 !ReferenceAvailable :hFp://www.marubeni.com/dbps_data/news/2006/061026e.html[Accessed19Sep2016]
TypeofPowerPlant: ���Gas-firedorOil-firedCombinedCycle,710MW• 2unitsofGasTurbineGenerators;
CalledasGT51andGT52innewtechnologyHybridandDryLowNoxBurner
• 2unitsofHeatRecoverySteamGenerator(HRSG)
• SteamTurbineGeneratorx1
REMARKNOxstandforNitrogenOxide;NOandNO2
DIFFUSIONFLAME
PREMIXFLAME
4 !
DiffusionFlame
FlameTemperatureandNOxEmission
5 !
AnalyzeinacaseofBC5wasnotabletooperateinoil-firedmodein2015
StartUp CleanLanceTube(inDiffusionBurner)NO
YES
OperatetoreachBaseload(250MW)
LoadIncreasedbyDiffusionMode
SwitchfromDiffusionModetoPremixmode
LoadIncreasedbyPremixMode
YES
NormalOpera]on
NO
RecalibrateOutletTemperatureControl 6 !
PURPOSEOFPROJECTPROBLEM:Cannotdo7-dayshutdownplantto
cleanthefueloillancetubes
So,Objec]veisto
Shortenprocessing]metomakeitfitto
Combus]onInspec]on1-yearonce
7DayOutage
NormalSolu]on:
Take7daysduringplantoutagetocleanequipment
MajorOverhaul6-yearonce37DayOutage
HotGasPathInspec]on(HGPI)
3-yearonce27DayOutage
7 !
BC5PLANOUTAGEINTERVAL
HotGasPath
Inspec]on3Year
CI1Year
MajorOverhaul(6Year)
*Combus2onInspec2on(CI)
37Days(MO)
7Days(CI)27Days(HGPI)
8 !
LIST OriginalCleaningProcess Dura]on ModifiedProcess Dura]on
Inspec2on
DisassemblingallcomponentsinsidesCombus2onChamber
2Days
-DisassemblingBurnerFuelOilLanceTubes(only) 0.5Days
Inspec2onbyBoroscope -Inspec2onbyBoroscope
ChemicalSec2on
Immersioncleaningincitricacidinultra-sonicbath
2Days
-Immersioncleaninginoilremoverwithpump
0.75DaysRisingwithpump -Risingwithpump
FlushandPassiva2on -
ReverseBlowoffandSucking -ReverseBlowoffandSucking
Preserva2on -
Inspec2on(AcerClean)
Inspec2onbyBoroscope
3Days
-Inspec2onbyBoroscope
0.5DaysFlowMeasurement -
Repor2ngacercleaningAssemblingBurnerandSwirler
-AssemblingLanceTubes
Total 7Days 1.75Days9 !
MODIFYPROCESSFORFASTERDISASSEMBLINGTUBE
(c)Aheadofburnerfueloillancetubethatlockwithaplant
(b)Aburnerfueloillancetube
Figure2!
10 !
(a)Aplate;usestoconnectaboltforpullingburnerfueloillancetubeoff
FASTERDisassembletheLancetube
STEP 1 : Disassembling only Burner Fuel OilLance Tubes by using an orange plate(Figure3-4) combined with bolts to holdt h e t u b e s o u t f r o m b u r n e r . !
Figure3:Anorangeplatewithtwobolts–atoolusestoholdburnerfueloillance
tubeandthenpullthetubeoff
11 !
Figure5:BurnerFuelOilLanceTubes
Figure4:duringusesaplanttoholdburnerfueloillancetube
12 !
Inspec2onResult-BeforeCleaning-
SeeinthisFigure7:
Insideoftheburnerfueloillancetubethathadoilstain
Figure6:BurnerFuelOilLanceTubes
ChemicalCleaningSec]on
13 !
Theburnerfueloillancetubeswereimmersedinoilremoverwhichhaschemicalpropertytocleanoilstainas
citricaciddoes.
Circulatethesolu]onbypumpfor12hours
Remark:preferultrasonicbathsystem.Butifthebathisnotavailablesoyoucanusecircula2onand
takelongersoaking2meinstead
Original ! New!
1.Citricacid! 1.Oilremover!2.UsingUltrasonicBathtakesafewhoursper6tubes!
2.Circulatethesolu]onbypumpfor12hoursforalltubes(24tubes) !
Figure8:12hourschemicalimmersionforwashingtheburnerfueloillancetubes
Inspec]onResultcomparebetweenoriginalandmodified(new)methods
Figure9:Cleansurfaceoftheburnerfueloillancetubeacerwashingprocess
14 !
Conclusion
1.DecreasingmanhourforBurnerWashingprocess2.ProvidingfirmFuelOilOpera2onreliabilitytoPowerPlant3.Inemergencycaseofunabletostartupplantduetohotspot,thetrainedstaffsinpowerplantcanimplementthiscleaningprocessthemselvesin2days.
Benefit
Burnerwashingprocesswasselectedtosolvethehotspotissue
TroubleShoo]ng1.Fueloilopera2onfailedinDiffusionModeduetohotspotissueAssump2on:Causeoffailurewerecokingandoilstaininburner2.Combu2onInspec2onDura2on(7days)was2meconstraintofindoutsuitablesolu2onforhotspotissue
Troubles
OriginalBurnerCleaningProcedure
7days !
NewBurnerCleaningProcedure
2days !
Created
15 !
THANKYOUFORYOURATTENTION!