6
FSC-25N CHANNEL GUARD 24FSC25N SECTIONAL VIEW PLEASE READ PLEASE READ THESE INSTRUCTIONS THOROUGHLY PRIOR TO BEGINNING THE FSC-25N CHANNEL GUARD INSTALLATION! THIS INSTRUCTION SHEET IS INTENDED TO PROVIDE A SPECIFIC GUIDE TO FOLLOW FOR THE INSTALLATION OF FSC-25N CHANNEL GUARD. CONTAINED WITHIN IS THE THE TECHNICAL INFORMATION AND INSTALLATION TECHNIQUES REQUIRED TO COMPLETE AN EFFICIENT, NEAT AND LONG-LASTING INSTALLATION. INSPECT ALL MATERIALS FOR DAMAGE OR MISSING PARTS. IF YOU DISCOVER DAMAGED OR MISSING MATERIALS, IN THE USA PLEASE NOTIFY THE FACTORY AT (800) 233-8493, AND IN CANADA (888) 895-8955. FSC-25N CHANNEL GUARD MUST BE INSTALLED IN ACCORDANCE WITH THESE INSTRUCTIONS! FAILURE TO FOLLOW THESE INSTRUCTIONS MAY VOID ANY PRODUCT WARRANTIES AND RESULT IN AN UNSUCCESSFUL INSTALLATION. FOR SPECIFIC QUESTIONS REGARDING THE INSTALLATION OF FSC-25N CHANNEL GUARD PLEASE CALL THE FACTORY IN THE USA AT (800) 233-8493 OR EMAIL [email protected]. IN CANADA CALL (888) 895-8955. IMPORTANT NOTES 1. ALL MATERIAL TO BE SUPPLIED IN STOCK LENGTHS. ALUMINUM RETAINER IN LENGTHS UP TO 20'-0" AND ACROVYN COVERS IN LENGTHS UP TO 10'-0". THIS MATERIAL IS TO BE FIELD CUT USING QUALITY EQUIPMENT TO INSURE THAT ALL CUTS ARE SQUARE. WHEN CUTTING MATERIAL SECTIONS, CS RECOMMENDS USING AN 80-100 TOOTH CARBIDE TIPPED SAW BLADE OR EQUIVALENT, TO MINIMIZE CHIPPING AND MAINTAIN JOINT ALIGNMENT. 2. ALL DIMENSIONS ARE TYPICAL. 3. FOR DRYWALL/PLASTER WALL CONSTRUCTION, IT IS RECOMMENDED FOR FASTENERS TO BE ENGAGED INTO METAL/WOOD STUDS TO MAINTAIN MAXIMUM PULLOUT STRENGTH. IF DURING INSTALLATION YOU ENCOUNTER SPECIAL WALL CONDITIONS THAT DO NOT ALLOW FOR ATTACHMENT FOR DIRECT ATTACHMENT TO THE STUDS PLEASE CONSULT THE LOCAL AUTHORITY HAVING JURISDICTION. 4. MATERIAL MUST REACH 65°F MIN. TO 75°F MAX. 24 HOURS PRIOR TO INSTALLATION. THIS IS ESSENTIAL TO MINIMIZE EXPANSION AND CONTRACTION OF MATERIAL. 5. FOR MORE INFORMATION ON FLUSH MOUNTED CORNER GUARDS SEE OUR WEBSITE AT www.c-sgroup.com. STUD WIDTH FOAM TAPE G.W.B. (BY OTHERS) DRYWALL SETBACK STEEL/WOOD STUD (BY OTHERS) 2" [51.2mm] Doc#: II-24FSC25N Issue Date: 08/16/10 Rev Date: 12/07/17

FSC-25N CHANNEL GUARD - c-sgroup.com channel guard 24fsc25n sectional view please read please read these instructions thoroughly prior to beginning the fsc-25n channel guard installation!

Embed Size (px)

Citation preview

FSC-25N CHANNEL GUARD

24FSC25N

SECTIONAL VIEW

PLEASE READ

PLEASE READ THESE INSTRUCTIONS THOROUGHLY

PRIOR TO BEGINNING THE FSC-25N CHANNEL

GUARD INSTALLATION!

THIS INSTRUCTION SHEET IS INTENDED TO PROVIDE

A SPECIFIC GUIDE TO FOLLOW FOR THE

INSTALLATION OF FSC-25N CHANNEL GUARD.

CONTAINED WITHIN IS THE THE TECHNICAL

INFORMATION AND INSTALLATION TECHNIQUES

REQUIRED TO COMPLETE AN EFFICIENT, NEAT AND

LONG-LASTING INSTALLATION.

INSPECT ALL MATERIALS FOR DAMAGE OR MISSING

PARTS. IF YOU DISCOVER DAMAGED OR MISSING

MATERIALS, IN THE USA PLEASE NOTIFY THE

FACTORY AT (800) 233-8493, AND IN CANADA (888)

895-8955.

FSC-25N CHANNEL GUARD MUST BE INSTALLED IN

ACCORDANCE WITH THESE INSTRUCTIONS! FAILURE

TO FOLLOW THESE INSTRUCTIONS MAY VOID ANY

PRODUCT WARRANTIES AND RESULT IN AN

UNSUCCESSFUL INSTALLATION. FOR SPECIFIC

QUESTIONS REGARDING THE INSTALLATION OF

FSC-25N CHANNEL GUARD PLEASE CALL THE

FACTORY IN THE USA AT (800) 233-8493 OR EMAIL

[email protected]. IN CANADA

CALL (888) 895-8955.

IMPORTANT NOTES

1. ALL MATERIAL TO BE SUPPLIED IN STOCK LENGTHS. ALUMINUM RETAINER IN LENGTHS UP TO 20'-0" AND ACROVYN COVERS IN

LENGTHS UP TO 10'-0". THIS MATERIAL IS TO BE FIELD CUT USING QUALITY EQUIPMENT TO INSURE THAT ALL CUTS ARE SQUARE.

WHEN CUTTING MATERIAL SECTIONS, CS RECOMMENDS USING AN 80-100 TOOTH CARBIDE TIPPED SAW BLADE OR EQUIVALENT,

TO MINIMIZE CHIPPING AND MAINTAIN JOINT ALIGNMENT.

2. ALL DIMENSIONS ARE TYPICAL.

3. FOR DRYWALL/PLASTER WALL CONSTRUCTION, IT IS RECOMMENDED FOR FASTENERS TO BE ENGAGED INTO METAL/WOOD

STUDS TO MAINTAIN MAXIMUM PULLOUT STRENGTH. IF DURING INSTALLATION YOU ENCOUNTER SPECIAL WALL CONDITIONS

THAT DO NOT ALLOW FOR ATTACHMENT FOR DIRECT ATTACHMENT TO THE STUDS PLEASE CONSULT THE LOCAL AUTHORITY

HAVING JURISDICTION.

4. MATERIAL MUST REACH 65°F MIN. TO 75°F MAX. 24 HOURS PRIOR TO INSTALLATION. THIS IS ESSENTIAL TO MINIMIZE EXPANSION

AND CONTRACTION OF MATERIAL.

5. FOR MORE INFORMATION ON FLUSH MOUNTED CORNER GUARDS SEE OUR WEBSITE AT www.c-sgroup.com.

STUD

WIDTH

FOAM TAPE

G.W.B.

(BY OTHERS)

DRYWALL

SETBACK

STEEL/WOOD

STUD

(BY OTHERS)

2"

[51.2mm]

Doc#: II-24FSC25N Issue Date: 08/16/10 Rev Date: 12/07/17

AutoCAD SHX Text
1

FSC-25N (1/2" DRYWALL)FSC-25N (5/8" DRYWALL)

FSC-25N (2 LAYERS

OF 5/8" DRYWALL)

FSC-25N (2 1/2" STUD WALL

and 5/8" DRYWALL)

FSC-25N CHANNEL GUARD

SECTIONAL VIEWS

24FSC25N

STUD WIDTH STUD WIDTH

STUD WIDTH

STUD WIDTH

2"

[51.2mm]

1 5/8"

[41.3mm]

DRYWALL

SETBACK

FOAM TAPE

STEEL/WOOD

STUD

(BY OTHERS)

G.W.B.

(BY OTHERS)

STEEL/WOOD

STUD

(BY OTHERS)

STEEL/WOOD

STUD

(BY OTHERS)

FOAM TAPE FOAM TAPE

STEEL/WOOD

STUD

(BY OTHERS)

G.W.B.

(BY OTHERS)

1 3/4"

[44.6mm]

DRYWALL

SETBACK

FOAM TAPE

G.W.B.

(BY OTHERS)

1 5/8"

[40.6mm]

DRYWALL

SETBACK

2"

[51.2mm]

G.W.B.

(BY OTHERS)

2"

[51.2mm]

1 5/8"

[41.3mm]

DRYWALL

SETBACK

2"

[51.2mm]

R1/4"

[R6.4mm]

R1/4"

[R6.4mm]

R1/4"

[R6.4mm]

R1/4"

[R6.4mm]

Doc#: II-24FSC25N Issue Date: 08/16/10 Rev Date: 12/07/17

AutoCAD SHX Text
2

WALL CONDITION SPECIFIED FASTENER

DRILL DIAMETERS

CS PART

NUMBER

WALL RETAINER

SINGLE LAYER DRYWALL #6 X 1-5/8" BUGLE HEAD SHEET METAL SCREW N/A N/A 90H079002

DOUBLE LAYER DRYWALL #8 X 3" BUGLE HEAD SHEET METAL SCREW N/A N/A 90H857002

FSC-25N CHANNEL GUARD

COMPONENTS & WALL FASTENERS

24FSC25N

FSC-25N ACROVYN COVER FSC-25N

ALUMINUM RETAINER

(24A285000 - 1/2" DRYWALL)

(24A284000 - 5/8" DRYWALL)

GASKET

(24M013xxx)

ALUMINUM BASE

(24F013000 - 4")

(24F148000 - 6")

1" ALUMINUM

CLOSURE CAP

(24F095000)

3/4" FOAM TAPE

(90M008002C)

Doc#: II-24FSC25N Issue Date: 08/16/10 Rev Date: 12/07/17

AutoCAD SHX Text
3

FULL HEIGHT PARTIAL HEIGHT

STANDARD DEDUCTIONS

FSC-25N CHANNEL GUARD

24FSC25N

RETAINER

LENGTH

EQUALS

CEILING

HEIGHT

PLUS 2"

[50.8mm]

2"

[50.8mm]

BASE

HEIGHT

1/16" [1.6mm]

GASKET

COVER

LENGTH

EQUALS

RETAINER

LENGTH

MINUS

BASE

HEIGHT

AND

1/16"

[1.6mm]

FINISH CEILING

ALUMINUM RETAINER

FINISH FLOOR

RETAINER

HEIGHT

EQUALS

FINISH

HEIGHT

PLUS

1" [25.4mm]

BASE

HEIGHT

1/16" [1.6mm]

GASKET

COVER

LENGTH

EQUALS

FINISH

HEIGHT

MINUS

BASE

HEIGHT

AND

1/8" [3.2mm]

1/16" [1.6mm]

GASKET

1"

[25.4mm]

ALUMINUM CLOSURE

CAP

ALUMINUM

RETAINER

CEILING

HEIGHT

Doc#: II-24FSC25N Issue Date: 08/16/10 Rev Date: 12/07/17

AutoCAD SHX Text
4

FULL HEIGHT PARTIAL HEIGHT

FSC-25N CHANNEL GUARD

TYPICAL ASSEMBLY

24FSC25N

DRYWALL SETBACK CHART

1/2" THK. 5/8" THK.

5/8" (2) THK.

5/8" THK.

(2 1/2" STUD)

1 3/4"

[44.5mm]

1 5/8"

[44.5mm]

1 5/8"

[44.5mm]

1 5/8"

[44.5mm]

18"

[457.2mm]

MAXIMUM

18"

[457.2mm]

MAXIMUM

DRYWALL SETBACK

(REF. CHART BELOW)

SPECIFIED

FASTENER

ALUMINUM

RETAINER

G.W.B.

(BY OTHERS)

STEEL/WOOD STUD

(BY OTHERS)

PRE-PUNCHED

HOLES

BLACK ACROVYN GASKET

ALUMINUM BASE

FOAM TAPE

ACROVYN

COVER

BLACK ACROVYN

GASKET

ALUMINUM BASE

FOAM TAPE

ACROVYN

COVER

PRE-PUNCHED

HOLES

STEEL/WOOD STUD

(BY OTHERS)

G.W.B.

(BY OTHERS)

ALUMINUM

RETAINER

ALUM. CLOSURE CAP

REQ'D AT PARTIAL

HEIGHT APPLICATIONS

BLACK ACROVYN GASKET

Doc#: II-24FSC25N Issue Date: 08/16/10 Rev Date: 12/07/17

AutoCAD SHX Text
5

1. ALL FLUSH MOUNTED CORNER GUARDS ARE SHIPPED WITH

CUT-TO-LENGTH ALUMINUM RETAINERS WITH FACTORY

DRILLED HOLES IN THE RETAINER.

2. WHEN INSTALLING THE GYPSUM BOARD OR PLASTER,

CONSULT THE CHART ON PAGE 5 TO DETERMINE THE

SETBACK DISTANCE TO PROVIDE A SNUG FIT WHEN THE

RETAINER IS INSTALLED.

3. ALIGN EACH RETAINER WITH THE CORNER AND SECURE

EACH LEG THROUGH THE WALL INTO THE METAL/WOOD

STUDS USING THE SPECIFIED FASTENERS. MAKE SURE

THE RETAINER REMAINS PLUMB WITH THE FINISH FLOOR.

NOTE: FOR SINGLE LAYER DRYWALL UNITS WITH STUDS WIDER

THAN 3 5/8" OR DOUBLE GWB APPLICATIONS, THE BASE, TOP

CAP AND ASSOCIATE PARTS HAVE BEEN FACTORY SPLIT. THE

SNAP-ON BASE AND TOP CAP HAVE BEEN WELDED TO

ACCOMMODATE THE EXTRA WIDTH. THE ACROVYN GASKET IS

SHIPPED IN PARTS, WITH EXTRA PIECES INCLUDED, SO THE

INSTALLER CAN FABRICATE A WORKABLE GASKET.

4. INSERT ALUMINUM BASE CLOSURE AT THE BASE OF THE

RETAINER AND SECURE THE ACROVYN GASKET ON TOP.

ALIGN GASKET WITH OUTSIDE EDGE.

5. A 1" [25.4mm] CLOSURE CAP IS TO BE INSTALLED AT TOP OF

RETAINER ON PARTIAL HEIGHT GUARDS. FOLLOWING

PROCEDURES SIMILAR TO STEP 4.

6. APPLY 2" [50.8mm] JOINT TAPE ALONG THE EDGE OF THE

DRYWALL AND THE ALUMINUM RETAINER. FINISH THE

INSTALLATION BY APPLYING A UNIFORM FEATHERED JOINT

AT THIS LOCATION AS PER STANDARD CONSTRUCTION

PRACTICES. ALLOW TO DRY AND THEN SAND AS

REQUIRED. APPLY ADDITIONAL COATS, AS REQUIRED, TO

PROVIDE A UNIFORM AND NEAT FINISH. APPLY THE

PROCEDURE TO ANY "CLOSURE CAPS" USED ON PARTIAL

HEIGHT INSTALLATIONS.

7. FINISH WALL SURFACE AS SPECIFIED. BE SURE THAT THE

SELECTED FINISH IS APPLIED TO THE INSIDE SURFACE OF

THE REAR "CONTOURED" PORTION OF THE ALUMINUM

RETAINER.

8. APPLY A SINGLE THICKNESS OF FOAM TAPE ONTO BOTH

CORNERS AND A DOUBLE THICKNESS ALONG CENTER OF

ALUMINUM RETAINER.

NOTE: IF THE RETAINER HAS BEEN SPLIT, APPLY THE CENTER

TAPE ALONG ONE EDGE OF THE SPLIT.

9. FINISH INSTALLATION BY SNAPPING THE ACROVYN COVER

ONTO THE RETAINER.

FSC-25N CHANNEL GUARD

TYPICAL ASSEMBLY

24FSC25N

This document is the property of Construction Specialties, Inc. and contains CONFIDENTIAL PROPRIETARY INFORMATION

that is not to be disclosed to third parties and is not to be used without approval in writing from Construction Specialties, Inc.

Muncy, Pennsylvania ● (800) 233-8493 ● Fax (570) 546-5169

Mississauga Ontario ● (888) 895-8955 ● Fax (905) 274-6241

www.c-sgroup.com

ACROVYN

COVER

FOAM TAPE

DRYWALL

TAPE

FEATHERED

JOINT

WALL

FINISH

MATERIAL

BLACK ACROVYN

GASKET

COVE BASE

(BY OTHERS)

WALL FINISH

MATERIAL

2"

[51.2mm]

DRYWALL

SETBACK

(SEE CHART

ON PAGE 5)

STUD

WIDTH

Doc#: II-24FSC25N Issue Date: 08/16/10 Rev Date: 12/07/17

AutoCAD SHX Text
6
AutoCAD SHX Text
12/07/17