4 General Guide to Pump Selection
5 Guide to Performance Data
6 Pumping Definitions
7 - 14 2000/BS Series - Drainers
15 - 20 2600 Range
21 2000/BS Series/2600 - Electrical Information
22 - 26 3000/C Series - Sewage
27 - 33 3000/N Series - Sewage
34 - 35 Chopper Pumps
36 - 44 Great and Grey – Sewage
45 ATEX Approved Explosion Proof Submersible
46 Telemetry
47 Electrical Equipment
48 - 49 Soft Start Control Panels - Specification
50 3000 Series - Electrical Information
51 - 55 Godwin CD series
56 - 62 Godwin HL series
63 - 65 Godwin NC series
66 - 68 Godwin Heidra series
69 - 70 Solid Handling - Robot Range
71 - 73 Water Treatment
74 - 77 Mixers
78 - 79 Aeration - Radial Aerators
80 Radial Aerators - Oxygen Transfer Rate
81 Aeration - Flyjet and Hydroejectors
82 Pump Flotation Modules
83 - 84 Hoses and Fittings
85 Friction Loss in Pipe Fittings Chart
86 - 87 Weight Reference Guide
88 - 89 Conversion Factors
90 Flange Sizes
91 - 93 TotalCare
94 - 95 Birkenburn Reservoir Case Study
96 - 97 Mont Cuet Landfill Site Case Study
99 Contact Details
4
General Guide to Pump Selection
Check:-The Electrical Supply available – What Voltage, Single or 3 Phase and the MaximumAmperage. If the Power Supply is inadequate, please ask for details of Generators orconsider using a Flygt Prime Assisted Diesel Pump.
Total Head Requirement – The most important calculation to get right! It is the sumof the Total Static Head (the vertical distance from the Suction Strainer to the point ofDischarge) plus any Friction Loss allowances. When sizing a pump, the critical thingto determine is the Total Generated Head (TGH) requirement.
Calculation:-Static Suction (strainer to the pump) + Static Delivery (from pump to the point ofDischarge) + Friction Loss (resistance incurred by liquid when flowing through hoses)= Total Generated Head.
Dirty Water or Solids Handling?
Use Drainer Submersibles (BS Series) and General Purpose Diesels for Dirty Waterpumping and where particles are relatively small e.g. sand and gravel.
Use Sewage Submersibles (C/N Series) and Solids Handling Diesels for Sewagepumping and where particles are larger e.g. stones and debris.
The Information contained within this document is for guidance only and is accurate to the best ofour knowledge at time of going to print.
Guide to Performance Data
The following curves are QH charts showing the performance of the hydraulic unit atconstant shaft speeds. Q is represented as litres per second, and total head, H, is in metres.
The data represented in this section is for your guidance only. Detailed informationcan be obtained from your local Xylem Sales Engineer.
Head (m)
Flow (l/s)
Head (m)
Flow (l/s)
80
60
Impeller No. of Outlet dia. mm Through Motor rpm AvailableCode vanes CP vers let, mm rating kW versions
252 1 80 Ø52 4.4 2850 CP/CS254 1 80 Ø46 4.4 2850 CP/CS
C, D, H and N Pumps
The power consumption is shown onthe chart. The power consumptionvalues for two selected performanceduty points are shown by plottedstraight lines from the lower to theupper chart. The lower chart andcorresponding table provideperformance data for different impellersused in a high head 3102 pump.Additional charts for LT, MT and SHmodels are shown for each respectivepump type.
BS and D Pumps
The curve is the specified performanceof the impeller selected. The valuesshown are for a BS 2125 pump. Impellercharacteristics are coded as follows:LT=Low head. MT=Medium head.HT=High head. SH=Super High Head.
5
6
Pumping Definitions
Pumping is the addition of energy to a fluid, which is used mainly for the purpose of moving the fluid from one point to another.
Centrifugal Pumps
One which transfers energy to the liquid by means of an impeller; i.e. “a rotatingdevice equipped with suitable vanes”. (The liquid is therefore delivered in acontinuous and uninterrupted flow).
Positive Displacement Pumps
One which transfers energy to a liquid by means of a reciprocating piston, or similardevice, giving an intermittent or “pulsed flow”.
Ejector or Jet Pumps
By mixing a high speed drive medium with a low velocity pumped medium, an energy exchange is achieved converting velocity energy into pressure, giving a continuous flow.
Q= Capacity or VolumeH= Total HeadTotal Head= Static Head + Friction loss head.
Static Head
The head against which the pump must work when the liquid is stationary.
Friction loss head
The head generated by friction of moving liquid, against the walls of the discharge pipes.
P= Pump total pressure in metres.
Net Positive Suction Head (npsh)
Energy from an outside source i.e. static head or atmosphere pressure required to ensure liquid enters the pump volute.
Cavitation
Cavitation occurs when there is insufficient n.p.s.h. i.e., too low a suction pressureinduces cavitation. This causes erosion to the metal surfaces due to the vapourbubble collapsing, allowing the liquid to rush into the subsequent spaces at highvelocity, thus creating a water hammer effect.
7
2000 / BS Series - Bibo Drainers
Introduction
Flygt Type BS - Pumps are suitable for a very broad field of application. They areused for dewatering on construction sites for houses, streets and roads, tunnels androck caverns, harbours and dams, for drainage and ballast pumping in shipyards, fordrainage in the event of flooding in mines and industrial plants, for cooling, cleanwater and raw water supply, water spraying, etc.
The Type BS - Pump is of transportable design and requires no installation. All youneed to do is to lower it into water and start it. There is a type BS pump suitable forall applications - be it for high capacities, high heads, confined spaces or explosive environments.
The Type BS - Impeller is an open or semi-open channel impeller, made of abrasionresistant high chromium steel and designed specifically for handling mediacontaining highly abrasive materials, such as clay, sand and drilling fines etc.
8
2000 / BS Series Bibo Pumps
Can be installed in a variety of applications
The Type BS - Pump can stand directlyon the sump floor
The compact design enables Type BS -Pumps to be used in confined spaces -a 200mm diameter pipe is sufficient forthe slimmest pump
The head generated can be increasedby connecting two or more Type BS -Pumps in series
or can be suspended from a ropeor chain
9
A
B
A
B
A B StrainerOpening
Pump type mm mm mm
BS2052 530 200 5x18BS2066 520 385/405/288 7x21BS2102MT 505 390/430 7x40HT 505 375/390/335 7x40BS2125MT 710 485/515/535 6x50HT 710 465/390 6x50BS2151LT 745 640/655 10x42MT 745 640/655 10x42HT 745 570/590 10x42BS2201Cast IronMT 1200 620 15x45HT 1050 430 10x10AluminiumMT 1253 500 15x45HT 1050 430 10x10BS2250MT 1144 885/912 15x45HT 1144 830 15x45BS2400MT 1250 780 10x10HT 1250 680 10x10BS2610 570 230 7 x 16BS2620 620 275 7 x 16BS2640MT 760 375 8 x 18HT 760 342 8 x 18BS2660MTHT 832 430 9 x 18BS2670MT 955 500 10 x 20HT 955 480 10 x 20
Dimensions
10
BS 2052
A
B
Head (m)
Flow (l/s)
BS 2066
A
B
Head (m)
Flow (l/s)
Motor 2.2 kW, 2800rpmMax. power input 2.8 kWWeight 30kg
Dimensions: A=520mmB=362/375mmHose Size: 75mm
Motor 1 kW, 2700 rpmMax. power input 1.4 kWWeight 18kg
Dimensions: A=530mmB=200mm Hose Size: 50mm
BS 2052 and BS 2066
11
BS 2102 and BS 2125
BS 2102 MT & HT
A
B
Head (m)
Flow (l/s)
A
B
Head (m)
Flow (l/s)
BS 2125 MT & HT
Motor 3.7 kW/ 5.2 kW, 2850 rpmMax. power input 4.5 kW/6.3kWWeight 50kg
Motor MT 8.0 kW, 2800 rpmMax. power input 9.5 kWWeight MT 83kg HT 92kg
Dimensions:A=710mmB=MT 485/515/535mm HT 465mmHose Size: HT 75mm MT 150mm
Dimensions: A=505mm B=MT=395/430mm HT=375/390mm HoseSize: HT 75mm MT 100mm
12
BS 2151 and BS 2201 MT
BS 2151 MT & HT
A
B
Head (m)
Flow (l/s)
BS 2201 MT
A
B
Head (m)
Flow (l/s)Motor 37 kW, 2920 rpmMax.Power input 41 kW Weight MT Aluminium - 280 kg, Cast Iron - 445kg
Dimensions:A=1253mmB=500mmHose Size: 200mm
Dimensions: A=745mmB=MT 640/655mm MT=570/590mmHose Size: HT 100mm LT 150mm
Motor 20 kW, 2900 rpmMax. power input 23 kWWeight 165kg
13
BS 2201 HT and BS 2250
BS 2250 MT & HT
A
B
Head (m)
Flow (l/s)
BS 2201 HT
A
B
Head (m)
Flow (l/s)Motor 37 kW, 2920 rpmMax. power input 41 kWWeight HT Aluminium 240 kg Cast Iron 350kg
Dimensions:A=1050mmB=430mmHose Size: 100mm
Motor 54 kW, 1470 rpmMax. power input 58 kWWeight 540kg
Dimensions:A=1100mmB=950mm Hose Size: HT 150mm MT 200mm MT 250mm
14
BS 2400
BS 2400 MT & HT
A
B
Motor 90 kW, 2970 rpmMax. power input 97 kWOver temperature protection instator windingsWeight MT 900kg HT 985 kg
Dimensions:A=MT 1250mm HT 1251mm B=MT 778mm HT 680mmHose size: HT=100mm MT=150mm
Head (m)
Flow (l/s)
2600/Range Introduction
Introduction
Clearing your worksite of unwanted water is critical to productivity. Flooding meanstime delays, cost overruns and unsafe working conditions. To get to the bottom of any dewatering job, rely on Flygt 2600 pumps.
Undertaking tough dewatering jobs is what the Flygt 2600 series does best. Itensures that you can get on with the work at hand safely and reliably. All this, thanksto extreme portability, automatic operation, easy maintenance, lasting performance.
The Flygt 2600 series is built to last. Radically engineered from the ground up, theserobust dewatering pumps feature innovative hydraulics, durable materials and a practical, ergonomic design. The result is unmatched wear resistance, consistentperformance over time.
Flygt 2600 pumps cover low, medium, high and super-high pressures to handle mostany application for worksites of every size.
15
16
BS 2610 MT 110V Single Phase
0 1 2 3 4 5 6 7 8 10 0
2
4
6
8
10
12
14
Flow (l/s)
Head (m)
243
0
2
4
6
8
10
12
14
16
1820
234
0 2 4 6 8 10 12 14Flow (l/s)
Head (m)
Rated Power 0.85 kW, Weight 21kg
Rated Power 1.2 kW, Weight 21kg
BS 2610 MT 400V 3 Phase
2600 Range
Dimensions: Max. Height=570mmMax. Width=230mm Discharge Ø=2" Strainer Hole: 7x16mm
Dimensions: Max. Height=570mmMax. Width=230mm Discharge Ø=2" Strainer Hole: 7x16mm
17
BS 2620 MT
0
4
8
12
16
20
24
226
0 2 4 6 8 10 12 14 15 Flow (l/s)
Head (m)
0
5
10
15
20
25
30
226
0 5 10 15 20 25 30 35 40 Flow (l/s)
Head (m)
Rated Power 5.6 kW, Weight 51kg
BS 2640 MT
Dimensions: Max. Height=760mmMax. Width=375mm Discharge Ø=4" Strainer Hole: 8x18mm
2600 Range
Dimensions: Max. Height=620mmMax. Width=275mm Discharge Ø=3" Strainer Hole: 7x16mm
Rated Power 2.2 kW, Weight 32kg
18
BS 2640 HT
0
5
10
15
20
25
30
35
40
45
50
257
0 4 8 12 16 20 24 Flow (l/s)
Head (m)
0
5
10
15
20
25
30
35
40
226
0 10 20 30 40 50 60 Flow (l/s)
Head (m)
Rated Power 5.6 kW, Weight 51kg
Rated Power 10 kW, Weight 78kg
BS 2660 MT
2600 Range
Dimensions: Max. Height=832mmMax. Width=430mm Discharge Ø=6" Strainer Hole: 9x18mm
Dimensions: Max. Height=760mmMax. Width=342mm Discharge Ø=3" Strainer Hole: 8x18mm
BS 2660 HT
0
10
20
30
40
50
60
70
251
0 5 10 15 20 25 30 35 Flow (l/s)
Head (m)
0
5
10
15
20
25
30
35
40
45
226
0 20 40 60 80 100 Flow (l/s)
Head (m)
Rated Power 10 kW, Weight 78kg
Dimensions: Max. Height=832mmMax. Width=430mm Discharge Ø=4" Strainer Hole: 9x18mm
Rated Power 18 kW, Weight 141kg
BS 2670 MT
Dimensions: Max. Height=955mmMax. Width=500mm Discharge Ø=6" Strainer Hole: 10x12mm
2600 Range
19
20
BS 2670 HT
0
10
20
30
40
50
60
70
251
0 5 10 15 20 25 30 35 40 45 50Flow (l/s)
Head (m)
Rated Power 18 kW, Weight 141kg
Dimensions: Max. Height=955mmMax. Width=480mm Discharge Ø=4" Strainer Hole: 10x12mm
2600 Range
21
2000/BS Series/2600 - Electrical Information
When two pumps are driven by the same generator, the rating required is 1.5 timesthat indicated for a single pump
Some form of time lag should be connected to prevent both pumps from starting simultaneously, unless the generator has been selected for pumps to start simultaneously.
The Information contained within this document is for guidance only and is accurate to the best of ourknowledge at time of going to print.
BS2052 1.0 110 1 14.0 46 CAP 5
BS2052 1.0 230 1 3.8 17 CAP 5
BS2052 1.0 400 3 2.2 9.9 DOL 7.5
BS2066 2.2 400 3 4.5 26 DOL 20
BS2071 3.0 400 3 6.6 43 DOL 30
BS2075 3.7 400 3 7.1 36 DOL 25
BS2075 5.5 400 3 11.0 50 DOL 35
BS2084 7.5 400 3 13.0 78 DOL 55
BS2102 5.2 400 3 10.0 71 DOL 50
BS2125 8.0 400 3 15.0 125 DOL 90
BS2151 20.0 400 3 35.0 281 ATX 100
BS2201 37.0 400 3 65.0 430 ATX 150
BS2250 54.0 400 3 104.0 590 ATX 450
BS2400 90.0 400 3 148.0 1245 ATX 425
BS2610 0.9 110 1 11.0 38 CAP 5
BS2610 1.2 400 3 2.7 12 DOL 10
BS2620 2.2 400 3 4.7 27 DOL 20
BS2640 5.6 400 3 11.0 48 DOL 35
BS2660 10.0 400 3 19.0 107 DOL 75
BS2670 18.0 400 3 32.0 213 DOL 150
PumpModel
Kw(ShaftPower) PhaseVoltage
FLCAmps
StartingMethod
MinimumGeneratorin Kva toStart/Run
DOLStartingCurrentAMPS
22
Introduction
This series of pumps covers an extensive performance range and can be used in a variety of applications: from pumping sewage in treatment plants and municipalapplications to irrigation, industrial effluent, process water and raw water handling to applications in aquaculture and agriculture.
An extensive range of hydraulic sections, i.e. impellers and volutes, are available to handle the different types of media.
Built-in cooling system on all pumps rated above 9kW. Vanes are at the top of thepump impeller circulate cooling water through a narrow slot around the stator housing.
3000 / C Series - Sewage
Channel Impeller
C - Pumps are equipped with a shrouded, single or multi-vane impeller that runs in a volute. The shape and size of the impeller is designed to minimise clogging,which makes this pump ideal for wastewater applications.
Nevaclog®
The Nevaclog® impeller is designed specially for smaller C - Pumps. Nevaclog® hasexcellent flow passing properties, because all the parts that might cause cloggingwhen water is flowing at low speed through the impeller channel have beeneliminated. This, coupled with the volute’s design is what enables wastewater to flow freely.
3000 / C Series - Sewage
23
ø D
C
C
A
B
A
B
C - Pumps
CS3085 MT 480 603 350 75
CS3085 HT 450 512 320 75
CS3085 LT 1 638 660 380 100
CS3085 LT 2 638 655 400 100
CS3102 LT/150 720 718 400 150
CS3102 LT/100 640 718 400 100
MT 640 703 383 100
HT 640 698 340 100
CS3127 LT 870 776 439 200
MT/150 780 761 430 150
MT/100 700 761 406 100
HT (curve 480-485) 700 722 407 100
HT (curve 250-259) 700 714 380 80
HS 550 741 403 100
CS3152 LT 1150 1327 576 250
CS3152 MT 900 1228 530 200
CS3152 HT/100 773 1190 530 100
CS3152 HT/150 845 1190 530 150
HS3152 845 1190 490 150
CS3201 LT 1417 1598 1000 250
CS3201 MT 1150 1442 576 200
CS3201 HT 1050 1453 576 150
HS3201 1050 1453 576 150
CS3300 LT 1675 1920 1000 250
CS3300 MT 1624 1915 1000 200
CS3300 HT/200 1494 1827 1000 200
CS3300 HT/150 1443 1827 1000 150
FS3085 605 535 317 100
FS3102 660 619 315 100
FS3127 750 693 415 100
FS3152 LT 735 1055 465 100
FS3152 HT 710 1035 440 100
NS3301 1438 1680 1000 250
Pump type A B C øD
C 3085 MT and C 3102 MT/HT
Impeller No. of Outlet dia. mm Through Motor rpm AvailableCode vanes CP vers let, mm rating kW versions
430 1 100 Ø76 3.1 1400 CP/CS/MT252 1 80 Ø52 4.4 2850 CP/CS/MT
Flow (l/s)
Head (m)
00 10 20 30 40
2
4
6
8
10
12
14
16
Flow (l/s)
Head (m)
00 10 20 3025155 35
5
10
15
20
25
30
Flow (l/s)
Head (m)
00 5 10 15 20 25 30 35
2
4
6
8
10
12
C 3085 MT
C 3102 MT/HT
Discharge size: 75mm/100mm Weight: 116kgHeight: 718mm Maximum width: 640mmMotor rating: 3.1kW
Flow (l/s)
Head (m)
00 4 8 12 16 18
5
10
15
20
25
30
Discharge size: 75mm Weight: 71kg Height: 655mm Maximum width: 638mmMotor rating: 2.0kW
24
Impeller No. of Outlet dia. mm Through Motor rpm AvailableCode vanes CP vers let, mm rating kW versions
432 1 100 Ø76 2.0 1400 CP/CS252 1 80 Ø40 2.4 2840 CP/CS
C 3127 and C 3152
Flow (l/s)
Head (m)
00 10 20 30 40 50 60
5
10
15
20
25
30
35
40
Flow (l/s)
Head (m)
00 20 40 60 80
4
8
12
16
20
24
C 3127
Discharge size: 100/150mm Weight: 175kgHeight: 761mm Maximum width: 780mmMotor rating: 5.9/7.4kW
Flow (l/s)
Head (m)
00 50 100 150 200 250 300
2
6
4
8
10
Impeller No. of Outlet dia. mm Through Motor rpm AvailableCode vanes CP vers let, mm rating kW versions
616 2 250 102x102 8.8 950 CP/CT/CS430 1 250 100x115 13.5 1450 CP/CT/CS452 HT 1 150 76x76 13.5 1450 CP/CT/CS265 SH 1 100 40x40 150 2920 CP/CT/CS
Discharge size: 150/200mm Weight: 426kgHeight: 1228mm Maximum width: 900mmMotor rating: 13.5kW
Flow (l/s)
Head (m)
00 20 40 60 80 100 120
5
10
15
20
25
30
35
C 3152
25
Impeller No. of Outlet dia. mm Through Motor rpm AvailableCode vanes CP vers let, mm rating kW versions
430 1 100/150 100x110 5.9 1450 CP/CS250 HT 1 80 Ø58 7.4 2900 CP/CS
26
C 3201 and C 3300
C 3201
Impeller No. of Outlet dia. mm Through Motor rpm AvailableCode vanes CP vers let, mm rating kW versions
630 1 200 144x120 22 965 CP/CT/CS456 1 150 Ø100 30 1250 CP/CT/CS
Flow (l/s)
Head (m)
00 40 80 120 160 200 240
5
10
15
20
25
30
35
Flow (l/s)
Head (m)
00 20 40 60 80 100 120 140
51015202530
50
4045
35
Discharge size: 200/250mm Weight: 1218kgHeight: 1915mm Maximum width: 1624mmMotor rating: 54/44kW
Discharge size: 200/250mm Weight: 588kgHeight: 1442mm Maximum width: 1150mmMotor rating: 30/22kW
Impeller No. of Outlet dia. mm Through Motor rpm AvailableCode vanes CP vers let, mm rating kW versions
632 1 250 Ø190 44 970 CP/CT/CS452 1 150 90x96 54 1450 CP/CT/CS620 3 300 Ø102 44 975 CP/CT/CS
MT & HT
Flow (l/s)
Head (m)
00 100 200 300 400 500 600
5
10
15
20
25
30
35
Flow (l/s)
Head (m)
00 20 40 60 80 100 120 140 160
10
20
30
40
50
60
70
C 3300
N Pump Technology
Sustained high efficiency for wastewater handlingWith its unique semi-open, self-cleaning impeller, the N-pump series can handlefluids with high concentrations of fibrous material, whilst still maintaining a high levelof pumping efficiency over long duty periods. The special relief groove in the volutereduces the risk of clogging by creating a self-cleaning flow path through the pump.
27
3000/N Series - Sewage
N Series Pumps
N series pumps are available, contact your local Flygt Rental Centre for curve details:N 3085, N 3102, N 3127, N 3153, N 3171, N 3202, N 3301
Adaptive N-impellers
The Adaptive N-hydraulics further improves the self-cleaning characteristics of N-technology with unmatched clog-free performance. This is achieved through theunique axial movement of the Adaptive N-impeller.
The Adaptive N-impeller is designed to move axially upwards when needed,allowing the most bulky of rags and toughest of debris to pass through smoothly.After the debris has passed, the hydraulic pressure returns the impeller to its originalposition.
The axial movement of this hydraulic reduces stress on the shaft, seals, and bearings,thereby extending their lifespan. Ultimately clog-free performancerequires almost none, or at the very most, simple maintenance and servicing. All inall, the Adaptive N-hydraulics is your assurance of highly economical and reliablepumps that give you peace of mind.
28
N 3085 MT and N 3102 MT
Flow (l/s)
Head (m)
N 3085 MT
Discharge size: 75mmHeight: 655mmMotor rating: 2.0kWWeight: 71kgMaximum width: 450mm
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NP vers rating kW versions
460 2 80 2.0 1400 NP/NS/NT
Flow (l/s)
Head (m)
N 3102 MT and SH
Discharge size: 80mm/100mmHeight: 705mmMotor rating: 3.1/4.2kWWeight: 116kgMaximum width: 610mm
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NP vers rating kW versions
461 MT 2 100 3.1 1440 NP/NS255 SH 2 80 4.2 2890 NP/NS
29
N 3127 and N 3153 MT
Flow (l/s)
Head (m)
N 3127 MT and HT
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NP vers rating kW versions
437 MT 2 100/150 5.9 1450 NP/NS/NT487 HT 2 100 5.9 1450 NP/NS/NT
Discharge size: 100/150mmHeight: 765mmMotor rating: 5.9kWWeight: 170kgMaximum width: 725mm
N 3153 MT
Flow (l/s)
Head (m)
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NP vers rating kW versions
431 2 150 13.5 1455 NP/NT/NS433 2 150 13.5 1455 NP/NT/NS
Discharge size: 150mmHeight: 1068mmMotor rating: 13.5kWWeight: 252kgMaximum width: 834mm
N 3153 HT/SH and N 3171 LT/MT/HT
30
Flow (l/s)
Head (m)
N 3153 HT/SH
Discharge size: 80/100mmHeight: 1052mmMotor rating: 13.5/15.0kWWeight: 242kgMaximum width: 763mm
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NP vers rating kW versions
611 LT 2 250 15.0 965 NP/NS/NT431 MT 2 150 22.0 1460 NP/NS/NT452 HT 2 100 22.0 1460 NP/NS/NT
Flow (l/s)
Head (m)
Discharge size: 100/250mmHeight: 1299mmMotor rating: 15/22kWWeight: 460kgMaximum width: 1151mm
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NP vers rating kW versions
451 HT 2 100 13.5 1455 NP/NT/NS272 SH 2 80/100 15.0 2910 NP/NT/NS
N 3171 LT MT and HT
N 3171 SH and N 3202 LT/MT/HT
31
Flow (l/s)
Head (m)
0 10 20 30 40 500
10
20274
30
40
50
60
70
80
Flow (l/s)
Head (m)
Discharge size: 150/300mmHeight: 1571mmMotor rating: 22/45kWWeight: 900kgMaximum width: 1439mm
N 3171 SH
N 3202 LT MT and HT
Discharge size: 100mmHeight: 1179mmMotor rating: 22kWWeight: 366kgMaximum width: 884mm
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NP vers rating kW versions
274 LT 2 108 22.0 2925 NP/NS/NT
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NP vers rating kW versions
617 LT 2 250 22.0 970 NP/NS/NT433 MT 2 200 30.0 1475 NP/NS/NT454 HT 2 150 45.0 45.0 NP/NS/NT
32
N 3301 LT/MT 55kW
Flow (l/s)
Head (m)
0 50 100 150 200 250 300 350 400Flow (l/s)
Head (m)Discharge size: 250mm
Height NS: 1705mm
Motor rating: 55kW
Weight: 1110kg
Maximum width NS: 1439mm
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NS vers rating kW versions
620 LT 2 250 55 985 NP/NT/NS/NZ630 MT 2 250 55 985 NP/NT/NS/NZ632 MT 2 250 55 985 NP/NT/NS/NZ
N 3301 LT and MT 55kW
33
N3301 HT 55kW/70kW
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NS vers rating kW versions
454 2 150 70 1475 NP/NT/NS/NZ454 HT 2 150 55 1400 NP/NT/NS/NZ456 HT 2 150 55 1400 NP/NT/NS/NZ458 HT 2 150 55 1400 NP/NT/NS/NZA Selection of impellers are available on request; also Variable Frequency Drive Starters
N 3301 HT 55 kW
Flow (l/s)
Head (m)
N 3301 454 HT Impeller 70 kW VFD Curves
Discharge size: 150mm
Height NS: 1641mm
Motor rating: 55/70kW
Weight: 920kg
Maximum width NS: 1242mm
0 20 40 60 80 100 120 140 160
80
70
60
50
40
30
20
10
0
Flow (l/s)
Head (m)
Chopper Pumps
34
Introduction
Chopper pumps with N Impeller Technology
Flygt Chopper pumps have the unique patented N Impeller along with a Hard Ironchopper ring which drastically reduces the risk of clogging. Rugged, wear resistant andself cleaning, it cuts through solids without clogging or sacrificing pump efficiency.
The Flygt Chopper pump range brings to an end troublesome and costly cloggingwith its heavy-duty and highly dependable chopping abilities. By adding the chopperfunction to the well proven Flygt N-pump, outstanding performance in heavy dutyapplications has been achieved. This new pump design has undergone extensivetesting in the field. The results from these tests show considerably fewer runningproblems and considerably lower energy consumption.
Typical applications: • Agriculture • Aquaculture • Food processing • Pulp and paper • Harsh wastewater facilities.
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NP vers rating kW versions
428 MT 2 100/150 4.7 1455 NP/NS/NT/NZ
N 3127 Chopper MT and HT
Discharge size: 100/15mmHeight NS: 765mmMotor rating: 4.7kWWeight: 170kgMaximum width NS: 725mm
Flow - [l/s]70605040302010
00
2
4
6
8
10
12
14
25
Chopper Pumps
35
Flow (l/s)
Head (m)
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NP vers rating kW versions
431 MT 2 150 13.5 1455 NP/NS/NT451 HT 2 100 13.5 1455 NP/NS/NT
Discharge size: 100/150mmHeight NS: 1068mmMotor rating: 13.5kWWeight: 252kgMaximum width NS: 763mm
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NP vers rating kW versions
431 MT 2 150 22.0 1460 NP/NS/NT451 HT 2 100 22.0 1460 NP/NS/NT
Discharge size: 100/150mmHeight NS: 1225mmMotor rating: 22.0kWWeight: 362kgMaximum width NS: 884mm
451
431
Flow (l/s)
Head (m)
N 3153 Chopper MT and HT
N 3171 Chopper MT and HT
36
Great and Grey - Sewage
After revolutionizing the market for small and midrange wastewater pumps, the FlygtN Pumps are now available in the larger units.
Introduction
• Incorporating the N Pump technology the potential for blockage issubstantially reduced
• Due to sustained efficiency, energy costs can be cut by up to 50%• Heads of up to 90mts achieved• Flows in excess of 700l/s
• General by-pass over-pumping• Pump replacement• Application proving• Storm water handling• Industrial effluent handling• Irrigation
Pumps from 90 to 250kW available to rent in NP/NS/NT and NZ build (see Page 37).Ex units available on request.
Applications
37
N and C Installation Method
Flygt centrifugal pumps are designed to pumpwastewater containing solids and fibres insuspension. The pump can also be used forpumping raw water.
Liquid temperature: max 40ºC (105ºF) Liquid density: max 1100 kg/m3
The pH of thepumped liquid: 6 - 11Depth of immersion: max 20 m (65 ft)
For pumping in an explosive or flammableenvironment the pump can be ATEX certified.
The Flygt pump is fully submersible, compactand easy to install. It is available in four versions,depending of the type of installation:
C/NP: This system with guide bars and dischargeconnection permits automatic connection of thepump to the discharge line. The pump can belifted up for inspection without anyone having toenter the sump. The pump works completely orpartially submerged under water.
C/NS: A transportable pump designed foroperating completely or partially submerged inthe pump liquid. It is equipped with base standand hose connection.
C/NT: The pump is installed vertically dry on abase stand and connected directly to the inletand outlet lines. The submersible design of thepump prevents damage in the event of flooding.
C/NZ: The pump is installed Horizontally dry on abase stand and connected directly to the inletand outlet lines. The submersible design of thepump prevents damage in the event of flooding.
For other applications, contact your local FlygtRental Centre for information.
P
S
T
Z
38
N3315 105kW
N3315 105kW 451HT 440mm
0
20
0 20 40 60 80 100 120 140 160
40
60
80
100
50Hz
45Hz40Hz
35Hz
POWER LIMIT
451HT
Flow (l/s)
Head (m)
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NS vers rating kW versions
451HT 3 150 105 1480 NP/NS/NT/NZ
Rated Power: 105kW
Weight: 1220kg
Dimensions: Max. Height=1992mmMax. Width=1450mm
39
N3231 85kW / 105kW
00
10
20
30
40
50
60
50 100 150 200 250 300 350
50Hz
45Hz40Hz
35Hz
POWER LIMIT
Flow (l/s)
Head (m)
N3231 85kW 480/360mm
Rated Power: 85kW
Weight: 1380kg
Dimensions: Max. Height=2060mmMax. Width=1570mm
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NS vers rating kW versions
480-360 3 200 85 1475 NP/NS/NT/NZ
N3231 105kW 480/400mm
0 50 100 150 200 250 300
POWER LIMIT
50Hz
45Hz
40Hz
35Hz
0
10
20
30
40
50
60
70
Flow (l/s)
Head (m)
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NS vers rating kW versions
480-400 3 200 105 1480 NP/NS/NT/NZ
Rated Power: 105kW
Weight: 1590kg
Dimensions: Max. Height=2060mmMax. Width=1570mm
N3231 125kW / 170kW
40
0 50 100 150 200 250 300 350 4000
10
20
30
40
50
60
50Hz45Hz40Hz
35Hz
Flow (l/s)
Head (m)
0 50 100 150 200 250 300 350
50Hz
45Hz
40Hz
35Hz
0
20
40
60
80
100
Flow (l/s)
Head (m)
POWER LIMIT
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NS vers rating kW versions
470-490 3 200 170 1480 NP/NT/NS/NZA Selection of impellers are available on request; also Variable Frequency Drive Starters
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NS vers rating kW versions
470-370 3 200 125 1450 NP/NT/NS/NZ
N 3231 170 kW 470/490mm
N 3231 125 kW 470/370mm
Discharge size: 200mm
Height NS: 2185mm
Motor rating: 125kW
Weight: 1760kg
Maximum width NS: 1390mm
Rated Power 170kW
Weight 1760kg
Dimensions: Max. Height=2305mmMax. Width=1570mm
41
N3231 170kW / 215kW
0 50 100 150 200 250 300 350 4000
10
20
30
40
50
60
70
80
90
100
POWER LIMIT
50Hz
45Hz
40Hz
35Hz
Flow (l/s)
Head (m)N3231 170kW 480/490mm
00
50 100 150 200 250 300 350 400
POWER LIMIT
35Hz
40Hz
45Hz
50Hz
102030405060708090
100110
Flow (l/s)
Head (m)
N3231 215kW 480/490mm
Rated Power 170kW
Weight 1760kg
Dimensions: Max. Height=2305mmMax. Width=1570mm
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NS vers rating kW versions
480-490 3 200 170 1480 NP/NS/NT/NZ
Rated Power 215kW
Weight 1910kg
Dimensions: Max. Height=2305mmMax. Width=1570mm
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NS vers rating kW versions
480-490 3 200 215 1485 NP/NS/NT/NZ
N3312 100kW / 180kW
42
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NS vers rating kW versions
670-450 3 300 100 985 NP/NT/NS/NZ670-545 3 300 180 990 NP/NT/NS/NZA Selection of impellers are available on request; also Variable Frequency Drive Starters
0 100 200 300 400 500 600 7000
5
10
15
20
25
30
35
50Hz45Hz
40Hz35Hz
40
Flow (l/s)
Head (m)
N 3312 180 kW 670/545mm
Rated Power: 100kW
Weight: 1975kg
Dimensions: Max. Height=2240mmMax. Width=1650mm
Rated Power: 180kW
Weight: 2275kg
Dimensions: Max. Height=2975mmMax. Width=1875mm
N 3312 100 kW 670/450mm
0 100 200 300 400 500 600 7000
10
20
30
40
50
60
50Hz45Hz
40Hz35Hz
Flow (l/s)
Head (m)
43
N3312 / N3356
N3312 250kW 670/585mm
0 100 200 300 400 500 600 7000
10
20
30
40
50
60
70
50Hz45Hz
40Hz35Hz
Flow (l/s)
Head (m)
Rated Power: 250kW
Weight: 3125kg
Dimensions: Max. Height=2975mmMax. Width=1875mm
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NS vers rating kW versions
670-585 3 300 250 990 NP/NS/NT/NZ
0 100 200 300 400 500 600 700
VFD Curves
0
5
10
15
20
25
30
35
40
50Hz45Hz
40Hz35Hz
Flow (l/s)
Head (m)
N3356 90 kW 670/470
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NS vers rating kW versions
670-470 3 350 90 985 NP/NT/NS/NZ
Discharge size: 350mm
Height NS: 2400mm
Motor rating: 90kW
Weight: 2200kg
Max. Width=1875 mm
44
N3356 / N3400
0 100 200 300 400 500 600 7000
5
10
15
20
25
30
35
40
50Hz45Hz
35Hz40Hz
Flow (l/s)
Head (m)N3356 100kW 670/475mm
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NS vers rating kW versions
670-475 3 350 100 985 NP/NT/NZ
Rated Power: 100kW
Weight: 1750kg
Dimensions: Max. Height=2275mmMax. Width=1900mm
N3400 250kW 670/575mm
Rated Power: 250kW Weight: 3750kgDimensions: Max. Height=3428mmMax. Width=1900mm
Impeller No. of Outlet dia. mm Motor rpm AvailableCode vanes NS vers rating kW versions
670-575 3 400 250 990 NP/NT/NZ
00
10
20
30
40
50
60
100 200 300 400 500 600 700 800 900 1000
POWER LIMIT
50Hz45Hz
40Hz35Hz
Flow (l/s)
Head (m)
45
Many of the Flygt range of pumps can be provided certified for use in Zone 1 andZone 2 hazardous areas.
Pumps are certified: EEx d IIB T4 or EEx d IIB T3
According to the pump model:
ATEX category II 2G
The pumps are constructed and approved in accordance with:
BS EN 50018, BS EN 50019, BS EN 13463-1, BS EN 60079-1, BS EN 60079-7
As appropriate according to the pump model.
For availability of ‘Ex’ units and any other technical assistance contact your nearestFlygt Rental Centre.
Explosion Pumps Available:
• Copies of the relevant ‘Ex’ certification can be made available on request. • The pumps are maintained in accordance with BS EN 60079 Part 19. • Before any Flygt ‘Ex’ pump is made available for Rental all parts, flame pathsetc; are checked and recorded using regularly calibrated instruments andprocedures in accordance with BS EN 60079-19
B Pumps C & N Pumps Mixers(ring forconfirmation)
2201 3085 46202400 3102 4630
3127 46403153 46503171 4660320233013231331233563400
ATEX Approved Explosion Proof Submersible Pumps
46
Telemetry
Mobile Telemetry & Alarms
Our Rental team is able to call upon the expertise of the Monitoring and ControlDivision of Xylem Water Solutions UK Ltd, and has many ways of monitoring theoverpumping installation, ranging from a simple “pay as you go” GSM alarm unitcapable of sending text messages to nominated numbers, to the D716x DynamicLogic Telemetry Outstation.
Flygt D716x Telemetry Alarm Unit
The Flygt D716x is a remote telemetry outstation/alarm unit utilising the mobiletelephone network or fixed PSTN telephone line.
This adaptable unit can monitor and be programmed to deliver an SMS textmessage to a number of mobile phones. The text message content is fullyprogrammable and can uniquely identify the problem or fault. The system iscompatible with all the major Telephone networks on 'Contract' or 'Pay As You Go'.
On larger installations for municipal Water Companies, The D716x is capable ofconnecting directly to an existing Telemetry Master Station.
The D716x Telemetry unit can be powered by different sources depending upon siteconditions. It can use alkaline batteries that power the unit for up to 7 years,depending on usage and temperature conditions, or is available in a dc-poweredconfiguration with an internal battery backup of up to 1 year.
47
Electrical Equipment
We specialise in electrical submersible pumps, therefore, it is logical that we are theexperts when it comes to the starter and controls that are required for a temporary pumping installation. From a simple single phase starter to a complexmulti pump 3 phase control panel, Rental Engineers are available to give advice onall aspects of electromotive power.
Our Rental team carry a comprehensive range of starters, isolators, controlequipment, alarm and monitoring devices. Also, sufficient cable to suit day to dayusage is stocked both at Nottingham and at all Rental Depot locations. For the largerand more complex installations we are able to select and supply the appropriateextension cables and junction boxes to connect the pump to the control panel. We can also supply ATEX Certified “Ex” junction boxes and cables glands for use in hazardous areas. If level regulators (floats) are used as the level control we cansupply the required I/S protection relays.
Variable Frequency Drives and Soft Start Units
Variable Frequency Drives are available to drive pump units from 10.0kW to200.0kW. The drives provide economical and intelligent pump control and can be configured for running wastewater pumps. With the intelligent VFD you canexpect all the advantages of speed regulation, plus top pumping efficiency.The 10.0kW to 55.0kW drives are IP54 rated and are suitable for use outdoors anddo not need an additional weather protective enclosure. The 200kW drives are available for indoor use or housed in a lockable mobile MotorControl Centre, complete with heating, ventilation, a distribution board is fitted alongwith internal lighting. 200.0kW is not the ceiling for the supply of VFD control panels,our Rental division have supplied a 400.0kW in its own Mobile MCC.
Also available is a range of Soft Start units for the smaller pumps that require simplebut efficient motor control.
48
Specification:• IP54 Zintex Panel• Rain canopy• Load break door interlocked isolator• Soft starter• Special wide ranging overload unit to protect different size pumps
• Earth leakage protection.• Hand/auto switch.• Door mounted alphanumeric keypad showing run & trip conditions and also containing – stop/reset-start buttons, Hand or auto LED’s, running LED and flashing tripped LED.
• Door mounted emergency stop (also to terminals)• Thermal Switch or Klixon trip circuit• Analogue output related to motor current• Inter-panel interlock system• Lifting hook• Motor & control connections wired to terminals• 12vdc control for floats• 24vdc , 100ma for optional alarm. • 24vdc , 500ma for optional ultrasonic unit• 24vac power supply customer use
The Heart of the Panel• Designed and manufacturedespecially for Rental from Xylem
• Unique wide ranging overload• Simple kilowatt selection willset up the overload protection
• Built in earth leakage• Thermal Switch or Klixon
Digital Display• Kilowatt selected• Running amps• Hand, auto, running and tripped led• Start and stop pushbutton• Last eight fault history
Soft Start Unit - 1.0 - 15kW
49
Specification :• IP54 free standing panel • Load break door interlocked isolator• Rain canopy• Torq-master 2000 soft starter• Motor output hard wired to 3 x 70mm stud terminals• Main contactor• By-pass contactor• Door mounted keypad (hand control)• 24v ac control system• Float switch control (hard wired)• Emergency stop circuit• Hand/auto selector switch• Remote connection via terminals (auto control)• Standard ‘t’ bar locking system• Lifting bar with hook• Earth leakage protection• Motor Thermal Switch or Klixon hard wired toterminals• Extra relay for telemetry – wired to terminals• Terminals for panel interlocking system• 24vdc , 100ma for optional alarm• 24vdc , 500ma for optional ultrasonic unit
The Heart of the Panel • Soft start unit • Pin locked menu• Adjustable pump range by amps• Adjustable too many starts protection• Float less control• Thermal Switch or Klixon connections• Electronic overload• Under load trip• Electronic shear pin
Information• Motor current• Ambient temperature• RMS Volts• Run hours• Service time indication (for the motor)• Motor status• Printable 1000 event data log
Soft Start Unit - 15 - 90kW
3000 Series - Electrical Information
3085 1.3 400 3 3.1 19 DOL 153085 2.0 400 3 4.5 19 DOL 153085 2.4 400 3 4.7 28 DOL 203102 3.1 400 3 6.9 33 DOL 253102 4.2 400 3 8.3 72 DOL 503127 4.7 400 3 9.6 56 DOL 403127 5.9 400 3 12.0 77 DOL 553127 7.4 400 3 14.0 114 DOL 803152 - 4 Pole 13.5 400 3 27.0 162 ASD 403152 - 2 Pole 15.0 400 3 28.0 229 ASD 553153 7.5 400 3 16.0 91 ASD 253153 9.0 400 3 19.0 107 ASD 253153 11.0 400 3 24.0 132 ASD 353153 - 4 Pole 13.5 400 3 28.0 150 ASD 353153 - 2 Pole 15.0 400 3 27.0 213 ASD 503170 15.0 400 3 31.0 210 ASD 503171 22.0 400 3 41.0 248 ASD 603201 30.0 400 3 56.0 365 ASD 853202 37.0 400 3 66.0 460 ASD 1103202 45.0 400 3 82.0 605 ASD 1503300 44.0 400 3 82.0 515 ATX 1503300 54.0 400 3 100.0 535 ATX 1503301-6 Pole LT 55.0 400 3 113.0 660 ATX 2253301-4 Pole MT 55.0 400 3 103.0 435 ATX 1503301 70.0 400 3 132.0 565 ATX 1953315 HT 105.0 400 3 199.0 1105 VFD 2103231 - 4 Pole 85.0 400 3 159.0 710 VFD 1703231 - 4 Pole 105.0 400 3 200.0 955 VFD 2103231 - 4 Pole 125.0 400 3 234.0 1525 VFD 2453231 - 4 Pole 170.0 400 3 300.0 2020 VFD 3153231 - 4 Pole 215.0 400 3 395.0 2945 VFD 4153312 - 6 Pole 100.0 400 3 202.0 1150 VFD 2103312 - 6 Pole 180.0 400 3 360.0 2215 VFD 3753312 - 6 Pole 250.0 400 3 465.0 2645 VFD 4853356 - 6 Pole 90.0 400 3 185.0 1160 VFD 1953356 - 6 pole 100.0 400 3 202.0 1150 VFD 2103400 - 6 Pole 250.0 400 3 465.0 2645 VFD 485
PumpModel
Kw(ShaftPower) Voltage Phase
FLCAmps
DOLStartingCurrentAMPS
StartingMethod
MinimumGeneratorin Kva toStart/Run
Solid Handling Products
When two pumps are driven from the same generator, the rating required is 1.5times that indicated for a single pump.
Some form of time lag should be connected to prevent both pumps from startingsimultaneously, unless the generator has been selected for multiple pumps to startsimultaneously.
The Information contained within this document is for guidance only and is accurate to the best of ourknowledge at time of going to print.
50
GodwinIn 2010 Xylem acquired Godwin Pumps, bringing with them over 100 years of experience in the design, manufacture, and supply of diesel pumps. GodwinPumps is renowned for quality, reliability, and long life.
Today, the product range is used throughout the world, in construction, industry, oilrefineries, chemical plants, mines, specialist offshore pumping, irrigation and waterdistribution.
Our Rental division now has access to Godwin’s range of automatic self-primingpumps adding an additional and wider range of Diesel driven Dri - Prime® pumps.The new Godwin pumps can be skid or trailer mounted for use in mobileapplications which can provide exceptional energy efficiency and a significantlyreduced clogging capability.
Godwin CD seriesThe Godwin CD range is ideal for high volume, medium head pumping and is capable of handling large solids.
Godwin HL seriesThe Godwin HL range is ideal for medium volume, high head pumping and is alsocapable of handling large solids-handling.
Godwin CD, HL, Heidra and NC series pumps are now available to rent from Xylem.
All models are available trailer mounted for safe on site transportation or with a skidbase. Cast Iron pump end construction, and sound attenuated enclosures.
3000 rpm
2600 rpm
2200 rpm
1800 rpm
1400 rpm
Minimum capacitylimitation
Maximum capacitylimitation
Hea
d (m
etre
s)
Flow
m³/hr
l/s
00
5
10
15
20
25
30
35
40
45
10 20 30 40 50 60 70 80 90 1000 2.5 5.5 8.5 12 14 17 19.5 22.5 25 28
CD80D Dri-Prime®Hush-Pac
The CD80M can handle solids up to 40mm in diameter. Allows for dry runningfor prolonged periods whileautomatically priming and repriming.This makes it an extremely effectivepump, suitable for both slurry, cleanwater applications as well as smalldewatering and bypass applications.
Godwin CD series
Overalldimensions
Length1621mm
Width853mm
Height1333mm
EngineOption
Kubota Z482
Suction connection 80 mm
Delivery connection 80 mm
Max capacity 65 m³/hr
Max Head 15 metres
Max Solids 40 mm
Max Suction Lift 8.5M
Wet Weight 725kgs
Impeller diameter 166 mm
Max working pressure 4.0 bar
Max operating speed 2000 rpm
Engine Kubota Z482
CD80M Kubota Z482
52
Godwin CD series
2200 rpm
2000 rpm
1800 rpm
1600 rpm
1400 rpm
1200 rpm
Minimum capacitylimitation
Maximum capacitylimitation
m³/hr
l/s
00
5
10
15
20
25
30
35
40
20 40 60 80 100 120 140 160 180 200 220 2400 5.5 12 17 22.5 28 33 39 44.5 50 55.5 66.562
Hea
d (m
etre
s)
Flow
CD100M Dri-Prime® Hush-Pac
Able to perform in the toughest conditions,the CD100M can handle solids up to 45 mmin diameter. Allows for dry running forprolonged periods while automaticallypriming and repriming. This makes it anextremely effective pump, suitable for bothslurry, clean water, sewer bypass and generaldewatering and many other applications.
Overalldimensions
Length1940mm
Width1050mm
Height1500mm
Suction connection 100 mm
Delivery connection 100 mm
Max capacity 200 m³/hr
Max Head 29 metres
Max Solids 45 mm
Max Suction Lift 8.5M
Wet Weight 1168kgs
Impeller diameter 220 mm
Max working pressure 3.8 bar
Max operating speed 2000 rpm
Engine Perkins 403D-15
CD100M Perkins 403D-15
EngineOption
Perkins 403D-15
53
Godwin CD series
m³/hr
l/s
00
5
10
15
20
25
30
35
40
50
45
50 100 150 200 250 300 350 400 450 550500
0 14 28 41.5 55.5 69 83.5 97 111 125 139 153
Hea
d (m
etre
s)
Flow
2200 rpm
2000 rpm
1800 rpm
1600 rpm
1400 rpm
1200 rpm
Minimum capacitylimitation
Maximum capacitylimitation
CD150M Dri-Prime®Hush-Pac
Able to perform in the toughestconditions, the CD150M can handlesolids up to 75 mm in diameter. Allowsfor dry running for prolonged periodswhile automatically priming andrepriming. This makes it an extremelyeffective pump, suitable for both slurryand clean water applications. Thepowerful CD150M has proven itself apump of choice for contractors, localauthorities, industrial andenvironmental companies.
Overalldimensions
Length2190mm
Width1050mm
Height1500mm
Suction connection 150 mm
Delivery connection 150 mm
Max capacity 329 m³/hr
Max Head 19 metres
Max Solids 75 mm
Max Suction Lift 8.5M
Wet Weight 1403kgs
Impeller diameter 260 mm
Max working pressure 4.8 bar
Max operating speed 1500 rpm
Engine Perkins 404D-22
CD150M Perkins 404D-22
EngineOptions
Perkins 404D-22
Perkins 1104D-44TA
54
Godwin CD series
CD300M Dri-Prime®Hush-Pac
The CD300M can handle solids up to95 mm in diameter. This makes it anextremely effective pump, suitable forboth slurry and clean waterapplications. The powerful CD300Mhas proven itself a pump of choice formines, quarries and many other highcapacity applications.
Suction connection 300 mm
Delivery connection 300mm
Max capacity 1380m³/hr
Max Head 54 metres
Max Solids 95 mm
Max Suction Lift 8.5M
Wet Weight 6620kgs
Impeller diameter 362 mm
Max working pressure 6.0 bar
Max operating speed 1800 rpm
Engine Caterpillar C9
CD300M Caterpillar C9
1800 rpm
1700 rpm
1600 rpm
1500 rpm
1400 rpm
1300 rpm
Minimum capacitylimitation
Maximum capacitylimitation
m³/hr
l/s
00
10
20
30
40
50
60
70
100 300200 400 500 600 700 1000900800 1100 1200 1300 14000 28 83.555.5 111 139 166.5 194 278250222 305.5 333 361 388
Hea
d (m
etre
s)
Flow
Overalldimensions
Length4850mm
Width2065mm
Height2545mm
EngineOptions
Perkins 1106D-E66TA
Caterpillar C9
55
Godwin HL series
HL80M Dri-Prime®Hush-Pac
The HL80M can handle solids up to 25mm in diameter. This makes it anextremely effective pump, suitable forboth slurry and clean waterapplications. The powerful HL80M hasproven itself a pump of choice forsewage handling, dewatering, localauthority usage and many otherapplications.
Suction connection 100 mm
Delivery connection 80 mm
Max capacity 80 m³/hr
Max Head 58 metres
Max Solids 25 mm
Max Suction Lift 8.5M
Wet Weight 1450kgs
Impeller diameter 315 mm
Max working pressure 10 bar
Max operating speed 2000 rpm
Engine Perkins 404D-22T
HL80M Perkins 404D-22T
m³/hr
l/s
00
8
16
24
32
40
48
56
64
72
80
96
88
112
104
10 20 30 40 50 60 70 80 90 1101000 2.5 5.5 8.5 12 14 17 19.5 22.5 25 30.528
Hea
d (m
etre
s)
Flow
2400 rpm
2200 rpm
2000 rpm
1800 rpm
1600 rpm
1400 rpm
Minimum capacitylimitation
Maximum capacitylimitation
EngineOptions
Perkins 404D-22T
Perkins 1104D-44T
Overalldimensions
Length2190mm
Width1050mm
Height1500mm
56
Godwin HL series
HL80M Dri-Prime®Hush-Pac
The HL80M can handle solids up to 25mm in diameter. This makes it anextremely effective pump, suitable forboth slurry and clean waterapplications. The powerful HL80M hasproven itself a pump of choice forsewage handling, dewatering, localauthority usage and many otherapplications.
Suction connection 100 mm
Delivery connection 80 mm
Max capacity 101 m³/hr
Max Head 68 metres
Max Solids 25 mm
Max Suction Lift 8.5M
Wet Weight 2200kgs
Impeller diameter 325 mm
Max working pressure 10 bar
Max operating speed 2100 rpm
Engine Perkins 1104D-44T
HL80M Perkins 1104D-44T
m³/hr
l/s
00
8
16
24
32
40
48
56
64
72
80
96
88
112
104
10 20 30 40 50 60 70 80 90 1101000 2.5 5.5 8.5 12 14 17 19.5 22.5 25 30.528
Hea
d (m
etre
s)
Flow
2400 rpm
2200 rpm
2000 rpm
1800 rpm
1600 rpm
1400 rpm
Minimum capacitylimitation
Maximum capacitylimitation
EngineOptions
Perkins 404D-22T
Perkins 1104D-44T
Overalldimensions
Length2890mm
Width1300mm
Height1800mm
57
m³/hr
l/s
00
8
16
24
32
40
48
56
64
72
80
96
88
112
104
10 20 30 40 50 60 70 80 90 1101000 2.5 5.5 8.5 12 14 17 19.5 22.5 25 30.528
Hea
d (m
etre
s)
Flow
2400 rpm
2200 rpm
2000 rpm
1800 rpm
1600 rpm
1400 rpm
Minimum capacitylimitation
Maximum capacitylimitation
HL125M Dri-Prime®Hush-Pac
The HL125M can handle solids upto 35 mm in diameter. This makes itan extremely effective pump,suitable for both slurry and cleanwater applications. The powerfulHL125M has proven itself a pump ofchoice for sewer bypass, generaldewatering and many otherapplications.
Suction connection 150 mm
Delivery connection 100 mm
Max capacity 275 m³/hr
Max Head 115 metres
Max Solids 35 mm
Max Suction Lift 8.5M
Wet Weight 3200kgs
Impeller diameter 370 mm
Max working pressure 6.0 bar
Max operating speed 2200 rpm
Engine Perkins 1106D-E66TA
HL125M Perkins 1106D-E66TA (129)
2400 rpm
2200 rpm
2000 rpm
1800 rpm
1600 rpm
1400 rpm
Minimum capacitylimitation
Maximum capacitylimitation
m³/hr
l/s
00
20
40
60
80
100
120
140
25 50 75 100 125 150 175 200 225 325275 3002500 7 14 21 28 35 41.5 48.5 55.5 62.5 9076 8369
Hea
d (m
etre
s)
Flow
Overalldimensions
Length3350mm
Width1300mm
Height1887mm
Godwin HL series
EngineOptions
Perkins 1104D-E44TA
Perkins 1106D-E66TA
58
m³/hr
l/s
00
20
40
60
80
100
120
160
140
50 100 150 200 250 4003503000 14 28 41.5 55.5 69 1119783
Hea
d (m
etre
s)
Flow
2400 rpm
2200 rpm
2000 rpm
1800 rpm
1600 rpm
1400 rpm
Minimum capacitylimitation
Maximum capacitylimitation
HL150M Dri-Prime®Hush-Pac
The HL150M can handle solidsup to 35 mm in diameter. Thismakes it an extremely effectivepump, suitable for both slurryand clean water applications. Thepowerful HL150M has provenitself a pump of choice forcontractors, local authorities,industrial and environmentalcompanies.
Overalldimensions
Length3350mm
Width1300mm
Height1887mm
Suction connection 150 mm
Delivery connection 150 mm
Max capacity 350 m³/hr
Max Head 125 metres
Max Solids 35 mm
Max Suction Lift 8.5M
Wet Weight 3400kgs
Impeller diameter 385 mm
Max working pressure 14.8 bar
Max operating speed 2200 rpm
Engine Perkins 1106D-E66TA
HL150M Perkins 1106D-E66TA (168)
Godwin HL series
EngineOptions
Perkins 1104D-E44TA
Perkins 1106D-E66TA
59
Godwin HL series
m³/hr
l/s
00
8
16
24
32
40
48
56
64
72
80
96
88
112
104
10 20 30 40 50 60 70 80 90 1101000 2.5 5.5 8.5 12 14 17 19.5 22.5 25 30.528
Hea
d (m
etre
s)
Flow
2400 rpm
2200 rpm
2000 rpm
1800 rpm
1600 rpm
1400 rpm
Minimum capacitylimitation
Maximum capacitylimitation
HL160M Dri-Prime® The HL160M can handle solids up to35 mm in diameter. This makes it anextremely effective pump, suitablefor both slurry and clean waterapplications. The powerful HL160Mhas proven itself a pump of choicefor mines, quarries and many otherhigh capacity applications.
Suction connection 200 mm
Delivery connection 150 mm
Max capacity 486 m³/hr
Max Head 187 metres
Max Solids 35 mm
Max Suction Lift 8.5M
Wet Weight 5944kgs
Impeller diameter 508 mm
Max working pressure 19 bar
Max operating speed 2000 rpm
Engine Volvo TAD951VE
HL160M Volvo TAD951VE
2000 rpm
1800 rpm
1600 rpm
1400 rpm
1200 rpm
Minimum capacitylimitation
m³/hr
l/s
00
20
40
60
80
140
120
100
160
180
200
50 100 150 200 250 300 350 5004504000 14 28 41.5 55.5 69 83.5 97 139125111
Hea
d (m
etre
s)
Flow
Maximum capacitylimitation
Overalldimensions
Length3700mm
Width1700mm
Height2200mm
EngineOptions
Volvo TAD951VE
Caterpillar C15
60
Godwin HL series
2000 rpm
1800 rpm
1600 rpm
1400 rpm
1200 rpm
Minimum capacitylimitation
Maximum capacitylimitation
m³/hr00
20
40
60
80
140
120
100
160
180
200
50 100 150 200 250 300 350 500450400
Hea
d (m
etre
s)
Flow
l/s0 14 28 41.5 55.5 69 83.5 97 139125111
HL160M Dri-Prime®Hush-Pac
The HL160M can handle solids upto 35 mm in diameter. This makesit an extremely effective pump,suitable for both slurry and cleanwater applications. The powerfulHL160M has proven itself a pumpof choice for mines, quarries andmany other high capacityapplications.
Overalldimensions
Length4580mm
Width2065mm
Height2545mm
Suction connection 200 mm
Delivery connection 150 mm
Max capacity 486 m³/hr
Max Head 187 metres
Max Solids 35 mm
Max Suction Lift 8.5M
Wet Weight 7000kgs
Impeller diameter 508 mm
Max working pressure 19 bar
Max operating speed 2000 rpm
Engine Volvo TAD951VE
HL160M Volvo TAD951VE
EngineOptions
Volvo TAD951VE
Caterpillar C15
61
Godwin HL series
m³/hr
l/s
00
8
16
24
32
40
48
56
64
72
80
96
88
112
104
10 20 30 40 50 60 70 80 90 1101000 2.5 5.5 8.5 12 14 17 19.5 22.5 25 30.528
Hea
d (m
etre
s)
Flow
2400 rpm
2200 rpm
2000 rpm
1800 rpm
1600 rpm
1400 rpm
Minimum capacitylimitation
Maximum capacitylimitation
HL250M Dri-Prime®Hush-Pac
The HL250M can handle solidsup to 65 mm in diameter. Thismakes it an extremely effectivepump, suitable for both slurryand clean water applications.The powerful HL250M hasproven itself a pump of choicefor mines, quarries and manyother high capacity applications.
Suction connection 300 mm
Delivery connection 250 mm
Max capacity 1224 m³/hr
Max Head 119 metres
Max Solids 65 mm
Max Suction Lift 8.5M
Wet Weight 9200kgs
Impeller diameter 440 mm
Max working pressure 13 bar
Max operating speed 2000 rpm
Engine Caterpillar C15
HL250M Caterpillar C15
m³/hr
l/s
00
1020
30
4050
6070
80
90
100
110
140
130
120
100 200 300 400 500 600 700 800 900 130012001000 11000 28 55.5 83.5 111 139 166.5 194 222 250 361333278 305.5
Hea
d (m
etre
s)
Flow
2000 rpm
1800 rpm
1600 rpm
1400 rpm
1200 rpm
Minimum capacitylimitation
Maximum capacitylimitation
Overalldimensions
Length5500mm
Width2700mm
Height2500mm
EngineOptions
Volvo TAD1215VE
Caterpillar C15
62
Godwin NC series
Godwin NC series
With two of the world’smarket leading pumpbrands, Flygt and Godwin,now under the Xylemumbrella, we havecombined the world’s mostreliable portable pumpswith the world’s mostefficient self-cleaninghydraulics to bring you themost efficient and reliableGodwin pumps ever.
The new range of GodwinNC pumps are not onlyreliable, they comeequipped with the non-clogging, performance of the proven Flygt N-technology.
This breakthrough combination gives you a best-in-class portable pump that deliverssustained hydraulic efficiency to handle tough wastewater pumping applications.
Self-cleaning Flygt N-technology saves costs
The high efficiency of Flygt N-technology is sustained over time due to its self-cleaning ability, keeping energy/fuel costs to a minimum.
Without a doubt, no matter what the challenge, you will always have the peace ofmind knowing that our Godwin NC Series Dri-Prime® pumps are on the job.
Godwin pumps, now with sustained high efficiency N hydraulics
• Self-cleaning reliability
• Hydraulic efficiency
• Non-stop optimum performance
• Long term energy/fuel savings
• Optimized operating speed for low energy/fuel consumption
• Low downtime
• Extended service intervals
• Minimum maintenance
• Service friendly
63
Godwin NC series
2200 rpm
2000 rpm
1800 rpm
1600 rpm
1400 rpm
1200 rpm
Minimum capacitylimitation
m³/hr
l/s
00
10
20
30
40
50
25 50 75 100 125 150 175 250200 2250 7 14 21 28 35 41.5 48.5 6955.5 62.5
Hea
d (m
etre
s)
Flow
NC100 Dri-Prime®
Features the unique patented N-technology with its innovative self-cleaningimpeller. Able to perform in the toughestconditions, the NC100 can handle solids upto 35 mm in diameter. This makes it anextremely effective pump, suitable for bothsewage and clean water applications. Thepowerful NC100 has proven itself a pumpof choice when pumping stringy materialand general dewatering applications.
Overalldimensions
Length2190mm
Width1050mm
Height1500mm
Suction connection 100 mm
Delivery connection 100 mm
Max capacity 188 m³/hr
Max Head 27 metres
Solids Handling 35 mm
Max Suction Lift 8.5M
Wet Weight 1345kgs
Impeller diameter 256 mm
Max working pressure 5.0 bar
Max operating speed 1800 rpm
Engine Perkins 403D-15
NC100 Perkins 403D-15
EngineOptions
Perkins 403D-15
Perkins 404D-22
64
Godwin NC series
0
10
20
30
40
50
60
70
Hea
d (m
etre
s)
m³/hr
l/s
0 50 100 150 250 300 350 42540020025 75 125 225 275 325 375175
0 14 28 41.5 69 83.5 97 111 11855.57 21 35 62.5 76.5 90 10448.5Flow
2200 rpm
2000 rpm
1800 rpm
1600 rpm
1400 rpm
1200 rpm
Minimum capacitylimitation
NC150 Dri-Prime®
Features the unique patented N-technologywith its innovative self-cleaning impeller.Able to perform in the toughest conditions,the NC150 can handle solids up to 42 mmin diameter. This makes it an extremelyeffective pump, suitable for both sewageand clean water applications. The powerfulNC150 has proven itself a pump of choicewhen pumping stringy material and generaldewatering applications.
Overalldimensions
Length2190mm
Width1050mm
Height1500mm
Suction connection 150 mm
Delivery connection 150 mm
Max capacity 241 m³/hr
Max Head 26 metres
Solids Handling 42 mm
Max Suction Lift 8.5M
Wet Weight 1410kgs
Impeller diameter 265 mm
Max working pressure 6.0 bar
Max operating speed 1600 rpm
Engine Perkins 404D-22
NC150 Perkins 404D-22
EngineOptions
Perkins 404D-22
Perkins 1104D-44T
65
Godwin Heidra series
Heidra Hydraulic Submersible Hush-Pac
When the suction lift is greater 8.5 m, Heidra pumps take over where Dri-Primepumps leave off. Heidra hydraulic submersibles are basically Dri-Prime pumps thathave been engineered to work submerged in the liquid they pump. Tough andreliable, Heidra pumps are designed for general pumping of light slurries andmunicipal sludges
Liquid bath mechanical seal = dry-running and reduced maintenance costs
Seals in pumps that often run dry can overheat and fail. Godwin mechanical shaftseals run in a liquid bath, which dissipates heat through the pump casing and allowsthe pump to run dry. This provides more reliable operation, frees operators fromclosely monitoring the pumps, while reducing maintenance costs.
Durable pump-end = long lifetime
Cast iron, the standard build, offers excellent durability.
Open impeller = versatility and fewer stoppages
With their open impeller design, Godwin Heidra pumps handle solids of up to125mm in diameter, reducing the risk of stoppages. The open impeller also meansyou can use Godwin pumps in a wide range of applications from water andwastewater, to drilling muds and industrial fluids.
66
Godwin Heidra NC series
Maximum capacity limitation
Minimum capacity limitation
0
5
10
15
20
25
30
35
40
Hea
d (m
etre
s)
Flow
l/s
m3/hr0 25 50 75 100 125 150 175 200 225
0 7 14 21 28 35 41.5 48.5 55.5 62.5
2000 rpm (1540 rpm)
1800 rpm (1386 rpm)
1600 rpm (1232 rpm)
1400 rpm (1078 rpm)
Delivery 100 mm Bauer
Inlet 100 mm c/w Strainer
Max capacity 200 m³/hr
Max Head 35 metres
Solids Handling 35 mm
Suction Lift No Limit
Wet Weight 1500kgs
Pump Weight 135kgs
Impeller diameter 256 mm
Max working pressure 4.0 bar
Max operating speed 2200 rpm
Engine Duetz F4M2011
HNC100 Duetz F4M2011
Heidra HNC100 - Duetz Power Pack
An extremely powerful yetcompact pump. Able toperform in the toughestconditions, the Heidra100NC can handle solids upto 35 mm in diameter. Thepowerful Heidra 100NC hasproven itself a pump ofchoice when pumping stringymaterial and generaldewatering applications.
67
Overall dimensions
Length 2200mm
Width 1050mm
Height 1845mm
Godwin Heidra NC series
2000 rpm (1540 rpm)
1800 rpm (1386 rpm)
1600 rpm (1232 rpm)
1400 rpm (1078 rpm)
Minimum capacity limitationMaximum capacity limitation0
5
10
15
20
25
30
35
Flow
Hea
d (m
etre
s)
l/s
m³/hr0 25 50 75 100 125 150 175 200 225 250 275
0 7 14 21 28 35 41.5 48.5 55.5 65.5 69 76
Delivery 150 mm Bauer
Inlet 150 mm c/w Strainer
Max capacity 225 m³/hr
Max Head 29 metres
Solids Handling 42 mm
Suction Lift No Limit
Wet Weight 1500kgs
Pump Weight 155kgs
Impeller diameter 280 mm
Max working pressure 5.7 bar
Max operating speed 2000 rpm
Engine Duetz F4M2011
HNC150 Duetz F4M2011
Heidra HNC150 - Duetz Power Pack
An extremely powerful yetcompact pump with flowcapabilities to 385 m³/hr anddischarge heads to 56 metres.Able to perform in the toughestconditions, the Heidra 150NCcan handle solids up to 42 mmin diameter. The powerfulHeidra 150NC has proven itselfa pump of choice whenpumping stringy material andgeneral dewatering applications.
68
Overall dimensions
Length 2200mm
Width 1050mm
Height 1845mm
Solids Handling - Robot Range
m³/hr
l/s
00
5
10
15
20
25
30
36 72 108 144 180 216 252
0 10 20 30 40 50 60 70
Head (m)
Flow
Flygt 100VX Robot
Heavy duty pump, for pumping rawsewage and slurries. The Vortex Flowdesign allows solids of up to 80mm topass through. Ideal for sewer by-passwork and where large solids are insuspension.
Connection Size 100mm
Max Capacity 180 m3/h
Max Head 19 Metres
Suction Lift 9 Metres
Max Solids 80mm
Air Handling 50 m3/h
Operating Speed 1500 rpm
Wet Weight 1484 Kg
Fuel Tank 150 Lts
Engine Duetz F2M2011
100VX
Fuel consumption 7.2 litres per hour at full speed
69
Solids Handling - Robot Range
Flygt 150VX Robot
Silenced, Heavy Duty pump, for pumpingRaw Sewage and Slurries. The VortexFlow design allows solids of up to100mm to pass through. Ideal for Sewerby-pass work and where large solids arein suspension.
Connection Size 150mm
Max Capacity 240 m3/h
Max Head 32 Metres
Suction Lift 8 Metres
Max Solids 100mm
Air Handling 50 m3/h
Operating Speed 1750 rpm
Wet Weight 1990 Kg
Fuel Tank 142 Lts
Engine Duetz F4M2011
150VX
0
4
8
12
16
20
24
28
32
36
40Head (m)
m³/hr
l/s
0 40 80 120 160 200 240 280 320 400360
0 11 22 33 44.5 55.5 66.5 78 89 111100Flow
Fuel consumption 7.2 litres per hour at full speed
70
71
Water Treatment
We can now rent water treatment products from our Sanitaire & Wedeco brands. Ourhigh-tech treatment systems can provide the most cost-effective solutions for ourcustomers without putting an undue burden on the environment.
Wedeco UV technology can be used to disinfect drinking water, wastewater andindustrial process water. UV treatment is chemical-free and an environmentallyfriendly alternative to chlorine disinfection. Our Wedeco systems use rays of UV lightto kill dangerous micro-organisms, including bacteria, viruses and yeasts, preventingthem from multiplying.
Sanitaire diffuser systems offer higher oxygen transfer efficiency, resulting in lowerairflow rates, lower back pressure and reduced cost over long term usage. They aregenerally employed for biological aeration, pre-discharge aeration and sludgeholding odour control.
Sanitaire Silver Series II
Sanitaire Silver Series II - Diffuser Grid
For a combination of high aeration efficiency andlow operating costs, there’s the Sanitaire SilverSeries II membrane diffuser – the most widelyused fine bubble diffused aeration systemavailable today.
The Sanitaire Silver Series II is well establishedand time proven in the market. This product is widely utilised in the municipal water industryfor standard and low-pressure aeration applications; and our LP (low pressure)membrane is an excellent solution for applications where the back pressure allowedon the blower is already defined, such as a refurbishment.
Xylem can now offer a complete fine bubble aeration system (4m x 2m) with ourmarket leading Sanitaire Silver Series II fine bubble membrane diffusers and a600m3/hr blower unit.
Description kW Voltage
Lift Out S/S Aeration Grid 4m x 2m c/w72 x 9" Sanitaire Membrane Diffuser Heads 30 400/3/50600m3/h Blower Unit 3m x 2m x2m
72
Wedeco Spektron
Wedeco Spektron
The Wedeco Spektron shines newlight on the environmentallyfriendly process of using UVdisinfection for drinking water.Featuring highly efficient UV lamptechnology and advanced flowdistribution, the Spektron series suitsmodern drinking water treatment plants and covers a wide array of applications from domesticwater supply and industrial uses to large municipal waterplants with a capacity of more than one thousand m3/h per unit.
Xylem now has Wedeco Spektron 400 and 600 UV reactors available to rent togetherwith their own control panel for ease of use and inspection. The Spektron range can be used in a number of applications where water treatmentis needed.
Description kW Voltage
Spektron 400300mm Dia x 2.5m S/S UV Reactor c/w
2.9 400/3/508 x 330w UV Lamps & Control Panel
Spektron 600350mm Dia x 2.9m S/S UV Reactor c/w
4.3 400/3/5012 x 330w UV Lamps & Control Panel
73
74
Mixers
Flygt Submersible Mixers consist of a drive unit and propeller, integrated into a compact unit. The mixer is mounted on a guide bar, to enable it to be raised andlowered, to operate at different depths. It can also be angled upwards or downwardand can be swivelled to the sides. Its mixing action can therefore be directed to anypoint in a lagoon or tank.
This flexibility aided by the large blade propeller, running at relatively low speeds,sets in motion large volumes of sludge and water. The Flygt submersible mixer is at least three times as efficient as a conventional mixer. This is due to the highefficiency hydraulic design and the fact that the motor and propeller are integratedinto a lightweight, compact unit. No energy is lost in complicated gearing, supportbearings and heavy shafts. Also, the mixer can be run intermittently, thus providingfurther energy savings.
Compact design
The machines are either direct-driven or include a reduction gearbox between themotor and the propeller. However, all models are well integrated into a compactunit. So no energy is lost in long heavy shafts and support bearings.
Circular tanks
One mixer is normally sufficient for tank volumes up to 2,000m3. Depending on thecharacteristics of the liquid and the desired degree of agitation, more than onemixer may be necessary for larger tank volumes.
Rectangular tanks
If the length, width and depth dimensions of the tank differ considerably, severalmixers may be necessary to ensure good results. Rectangular tanks are often locatedunderground. Since Flygt Mixers are installed from the top, installation in underground tanks is easy.
For specific duties on the range of Flygt Submersible Mixers please contact yourlocal service centre.
75
Homogeneous liquid manure in a couple of hours.
Flygt Submersible Mixers have an important role to play in agriculture, forhomogenising liquid manure. Even if the manure is old, with a thick dry crust and allthe solids have settled at the bottom of the tank, it will be possible by mixing for thewhole tank contents to become homogeneous. This is due to the fact that the mixercan operate at different depths, can be orientated in any direction and will quicklyset in motion large volumes of the manure.
Wide field of applications in industry
Flygt Submersible Mixers are used for keeping liquids of different viscosities in suspension, for mixing dry solids into liquids, for thickening after sedimenting anddecanting, and for transporting liquids,
Good environment in fish farming
Whether in netting enclosures in open water or in dammed bays, Flygt submersiblemixers will maintain ideal fish farming conditions at a modest cost. The mixer willsupply a briskly-flowing current of fresh water with good oxygen contents and an abundance of natural food. At the same time, fish droppings will be removed. Therisk of rotting and formation of decay gases is eliminated. By establishing circulationbetween the bottom and the surface , the mixer also evens out the watertemperature, which favours the growth of the fish.
Improving the efficiency in sewage treatment plants
Flygt Submersible Mixers have been widely adopted in sewage treatment plantsthroughout the world. Particularly in thickening, sludge and storm water ponds, in buffer tanks and in the mixing of chemicals and lime into the water, the efficiencyand low operating costs of the mixers can be utilised to the greatest possible extent.
Flow creation
For low head, high capacity laminar flows the large propeller mixer can be used in lake reservoirs, fish farms as well as process mixing.
Mixers in Practice
Mixers
As shown:
4620 1.5 kW mixer fitted on a portable, free standing steelwork - available to rent.
76
øA
GF
HE
øD
ø B
HG
øA MAX
Type
AB
CD
EF
GH
IWeights
(max)
Max
Max
mm
mm
mm
mm
mm
mm
mm
kg (lbs)
Ø mm
Ø mm
4410
2500
--
--
-1110
1010
100
230(507)
4430
2500
--
--
-1110
1010
100
263 (580)
4630
390
636
405
559
469
117
574
457
5061(134)
4640
390
636
405
559
509
117
614
497
5064 (141)
4650
650
1027
675
931
721
195
878
700
100
177 (390)
4660
650
1027
675
931
831
195
988
810
100
218 (481)
4670
880
1372
908
1256
835
264
992
816
100
363 (800)
4680
880
1372
908
1256
985
264
1192
966
100/150
482 (1063)
Available Mixers
77
Aeration - Radial Aerators
Fields of application
The efficient mixing characteristics and the simple design of our Ejectors andAerators make them suitable for aerating biological ponds, fishfarm ponds, lakes and waterways.
The function of the ejectors
The principle on which the Ejector operates is simple and well-known. A drive jetfrom a Flygt Submersible pump is led into the Ejector. The drive jet flows through a nozzle into the ejector housing, which has a delivery pipe for the medium, e.g. air,which is to be pumped (the secondary flow). A drop in pressure occurs when thedrive jet passes through the mixing tube. This partial vacuum automatically entrainsthe pump medium with the drive jet and the contents of the primary and secondaryflows are mixed intensively with each other.
The function of the Radial Aerator
Aeration by means of high efficiency mixing.
Air dispersion by the same method as the Ejector is distributed radially within a tank,basin or lagoon, via the series of diffusers mounted around a central turbineimpeller. As with the Ejectors, being totally submerged significant advantages ariseover other forms of aeration.
Low noise levels.
No sprays or liquid dispersion in the atmosphere.
Installation
Installation of these aeration products is straightforward either by bolting to the tankfloor or they even will be suspended by their own weight in certain circumstances.
Applications
Subject to the tank configuration the ejector oraerator can be selected to: Replace existingaeration equipment during breakdown ormaintenance periods. Upgrade existingtreatment capacity without major investment.Increase oxygen levels. Reduce ammonia levels.
78
Dimensions and Weight - Radial Aerators
A
B
C
Type Power Current Dimensions (mm) Weighta b c Kg*
308 2.4 4.5 610 660 50 75310 4.4 8.5 700 660 50 105312 5.9 11.0 800 950 80 180315 13.5 25.0 1130 995 100 295320 22 42.0 1320 1150 150 500
* Weight includes 10m of cable
79
81
Flyjet and Hydroejector
Utilising the principles of an Ejector; the Flyjet and Hydroejector can be used to resuspend solids which have settled in storage tanks.
They can be used in storm water retention tanks at sewage works;for example. 4” and 6” jet pipes are available.
82
Pump Flotation Modules
The conceptOur range of pump flotation modules has been developed to provide a light-weight and cost-effective alternative to the traditional steel pontoon. Theflotation modules are prefabricated from light-weight, foam-filled, GRP (Glass fibreReinforced Polymer) and are available in four sizes.
General applicationsPump Flotation Modules can be supplied to suit Flygt 2000 Series / BS dewateringpumps, C/N-series wastewater pumps and slurry pumps.• Applications include:
• Mine dewatering• Tailing dams• Underground dams• Sewage treatment
• Quarries• Aeration ponds• Construction site dewatering• Flooding control
InstallationThe pump and integral module can be simply installed by use of a central liftingattachment. Once in the water, the module can be towed by boat, if required, andsecured in position by anchor or guy ropes. The float module remains visible abovethe water surface for easy recovery.
By having the pump floating close to the surface, it increases service life throughreduced maintenance since it is no longer working within high solids environment.
• Compact and lightweight• Stainless steel metal parts• Easily mounted to pumpson site
• Lifting points for easy installation• Easy to transport as an integral unit• Foam filled to prevent sinking
PFM550
PFM550
PFM 550 Part Number2201 691 69 003140 *3152/3153 *3170/3171 *5100 (<52kW) *5150 (<52kW) *
* On request
1400 x 1400 x 540mm 20 kg
Design features:
83
To complement our comprehensive range of pumps, extensive stocks of pipeworkand hoses are held. Our Rental engineers can supply all your needs from 2” hoseincreasing in size to steel pipes in excess of 450mm.
Also BSP pipe and cast iron fittings to suit most applications including valve, taper,hose spigot, flexible couplings and hose clamps, specialised hoses for high pressureapplications are also stocked.
Hoses and Fittings
Hoses and Fittings
A tough hose developed for the construction industry, with a tube of smoothsynthetic rubber, covered with weather resistant synthetic rubber, reinforced withcords of synthetic textile and an embedded helix of high-tensile steel wire. It is flexible and heavy, yet easy enough to manoeuvre. It seals well onto the pipe fittings, withstands high pressure and is also tough. It is ideal for suctions and for discharge where the bend must not collapse.
SpecificationBore Outside Working Weight perdia. dia. Pressure 6m incl. cpgs mm in. mm bars kg
50 2 58 5 675 3 87 5.5 10100 4 115 4.5 25150 6 167 3 40
PVC is a high grade hose, flexible, lightweight, with exceptional resistance toabrasion and weathering. The smooth bore offers minimum resistance to flow. The strengthened PVC helix is embedded in the hose wall for extra strength.
PVC Suction andDischarge Hose
SpecificationBore Outside Working Weight perdia. dia. Pressure 6m incl. cpgs mm in. mm in. bars psi kg
50 2 65 2.5 6 90 875 3 90 3.5 4 60 14100 4 115 4.5 3 50 18150 6 170 6.75 3 50 43Polythene Delivery Hose
A pump relies on a secure link between the source and the discharge point. Poorhoses will leak, collapse and cause unwanted problems. So, at Xylem we only sellthose hoses we use ourselves – “Cheap hose is expensive hose in the long run”.
This is a proven semi-rigid delivery hose, which is well known throughout theindustry. It is damage resistant, but also lightweight and simple to handle. Friction loss is kept to a minimum in this smooth bore hose.
84
SpecificationBore Outside Working Weight perdia. dia. Pressure 6m incl. cpgs mm mm bars kg
51 63 8 1276 89 8 26102 116 8 35150 169 5 60
Wire-armouredSuction Hose
85
Friction Loss in Pipe Fittings Chart
The table refers to new pipes and moderate corrosion could increase resistance by30%. To calculate resistance of Bends and Fittings, an ‘equivalent length’ for eachaccessory needs to be added to the actual length of pipe. The equivalent length infeet can be estimated by multiplying the factors in the adjacent table by the pipediameter in inches.
Example :- A 6” Gate Valve is equivalent to 12 ft of extra pipe
Mitre elbow or tee 5Round elbow 3Slowbend 2Square edged entrance 3Gate valve fully open 2Globe valve fully open 10Non-return valve (flap type) 3Foot-valve and strainer (clean) 5
Losses in m/100 or ft./100ft
I.G.P.M.2” 3” 4” 6” 8” 10” 12” m3/h
50 10 1.4 0.3 1075 20 3 0.7 15100 35 5 1 0.1 20150 12 2.5 0.35 30200 18 4.5 0.6 50300 40 10 1.2 0.4 75400 18 2.2 0.7 100500 28 3.5 1.1 0.35 125600 38 4.5 1.5 0.5 150700 6.5 2 0.7 175800 8 2.7 0.8 200900 10 3.4 1 0.4 2251000 13 4 1.4 0.5 2501200 18 6 2 0.8 3001400 26 8 3 1 3501600 32 11 4 1.5 4001800 36 14 4.5 2 4502000 38 17 5 2.5 5002500 25 9 4 6503000 38 12 5 7504000 21 8 10005000 32 13 1250
m3/h x 4 = g.p.m. approx
Friction Loss In Smooth Bore Pipe
86
Weight Reference Guide - Pumps
The weights above DO NOT include Cable, Chains or HosesThe weights contained within this guide are an estimate only and the actual weight of the item to be
lifted must be separately assessed and verified
2052 18Kgs2066 30Kgs2102 50Kgs2125 Aluminium 89Kgs2125 Cast Iron 180Kgs2151 165Kgs2201MT Aluminium 280Kgs2201MT Cast Iron 445Kgs2201HT Aluminium 240Kgs2201HT Cast Iron 350Kgs2250 540Kgs2400 985Kgs2610 MT 21Kgs2620 MT 32Kgs2640 MT & HT 51Kgs2660 MT & HT 78Kgs2670 MT & HT 141Kgs3085MT 71Kgs3102MT 116Kgs3102SH 114Kgs3127MT 170Kgs3127HT 155Kgs3152LT 426Kgs3152MT 321Kgs3152HT 280Kgs3153 LT 379Kgs3153MT 252Kgs3153HT 232Kgs3153SH 242Kgs3171LT 460Kgs3171MT 362Kgs3171HT 321Kgs3201MT 588Kgs3201HT 540Kgs3202LT 900Kgs3202MT 610Kgs3202HT 580Kgs3300LT 1'175Kgs3300MT 1'188Kgs3300HT 988Kgs3301LT 1'110Kgs3301MT 1'030Kgs3301HT 920Kgs3315HT 1220Kgs
SubmersiblePump Type
BS/NS/CS Weight Inc Base Stand Large Submersible Pump Range
3231 85Kw 1'380Kgs - Pump Only3231 105Kw 1'590Kgs - Pump Only3231 125Kw 1'530Kgs - Pump Only3231 170Kw 1'760Kgs - Pump Only3231 215Kw 1'910Kgs - Pump Only3312 100Kw 1'975Kgs - Pump Only3312 180Kw 2'275Kgs - Pump Only3312 250Kw 3'125Kgs - Pump Only3356 100Kw 1'750Kgs - Pump Only3400 75Kw 2'700Kgs - Pump Only3400 250Kw 3'750Kgs - Pump Only
Original Flygt Diesel RangeFlygt Swell 100 - Full Fuel Tank 1'510KgsFlygt Swell 150 - Full Fuel Tank 1'790KgsFlygt ROBOT 100VX - Full Fuel Tank 1'484KgsFlygt ROBOT 150VX - Full Fuel Tank 1'990KgsFlygt 150WP - Full Fuel Tank 1'820KgsFlygt Swell 200 - Full Fuel Tank 1'750Kgs
Godwin Diesel Range - Skidbase HushpacCD80D - Kubota Z482 Engine - Wet Weight 725KgsCD100M - Perkins 403D-15 Engine - Wet Weight 1'168KgsCD150M - Perkins 404D-22 Engine - Wet Weight 1'403KgsCD300M - Caterpillar C9 Engine - Wet Weight 6'620KgsHL80M - Perkins 1104D-44T Engine - Wet Weight 2'200KgsHL125M - Perkins 1106D-E66TA Engine - Wet Weight3'200KgsHL150M - Perkins 1106D-E66TA Engine - Wet Weight3'400KgsHL160M - Volvo TAD 951VE Engine - Wet Weight 7'000KgsHL250M - Caterpillar C15 Engine - Wet Weight 9'200KgsNC100 - Perkins 403D-15 Engine - Wet Weight 1'390KgsNC150 - Perkins 404D-22 Engine - Wet Weight 1'410KgsHeidra 150 Duetz F4M2011 Power Pack - Wet Weight1'500KgsHNC100 Pump Only 135KgsHNC150 Pump Only 155Kgs
Mixers4620 18Kgs4630 60Kgs4640 63Kgs4650 174Kgs4660 209Kgs4670 345Kgs
Panels15Kw Soft Start 30Kgs90Kw Soft Start 130Kgs
Pump Type Weight
The Information contained within this document is for guidance only and is accurate to the best of ourknowledge at time of going to print.
87
Weight Reference Guide - AccessoriesSize
2" - 50mm
3" - 80mm
4" - 100mm
6" - 150mm
8" - 200mm
10" - 250mm
12" - 300mm
Cast Iron Pipe & Fittings
Kg
Kg
Kg
Kg
Kg
Kg
Kg
Gate Valve Metal Wedge
1723
3565
104
170
228
NRV Cast Iron Flap Type
1216
2137
69132
187
D/F Bend Short
1113
2234
5577
D/F Bend Long
1621
3452
74101
Duck Foot Bend
1519
3350
82116
Equal Tee
1721
3654
87115
Radial Tee
2634
5583
121
164
“Y” Piece
1720
3654
89127
Taper
810
1522
3346
VJFA
45
711
1520
Cast Iron Pipe Cement lined kg/M
1620
3040
5266
NP 16 Flange
56
810
1519
Hoses
Wire Armoured Hose C/W Bauers
6M12
2635
60PVC Suction & Discharge Hose C/W Bauers6M
610
2540
Polythene Semi Rgid Hose C/W Bauers6M
814
1843
Wire Armoured Hose C/W Bauers
3M50
95Wire Armoured Hose C/W Flanges
3M95
125
Steel “Bauer” Type Pipe & Fittings
2" - 50mm
3" - 76mm
41/4" - 108mm61/4" - 159mm75/8" - 194mm
Galvanised pipe
1M3
58
1520
Galvanised pipe
2M3
712
2030
Galvanised pipe
3M7
1116
3240
Bauer Ball Connector
0.2
0.3
11.5
2Bauer Level Closure Ring
0.5
11.5
46
Bauer Socket
0.1
0.3
0.6
1.2
2.5
Bauer 90 Deg Bend C/W Closure Ring
12.5
5.5
1113
Bauer Equal Tee C/W 2 Closure Rings
1.5
48
15Bauer Flanged with ball & Closure Ring
35
814
22Bauer Flanged with Socket
34
57
15
The weights contained within this guide are an estimate only and the actual weight of the item to be
lifted must be separately assessed and verified
Inches x 25.4 = mm x 0.0394 = Inches
Feet x 03048 = m x 3.281 = Feet
Yards x 0.9144 = m x 1.0936 = Yards
Miles x 1.609 = km x 0.6214 = Miles
Ft2 x 0.0929 = m2 x 10.764 = Ft2
Miles2 x 2.59 = km2 x 0.3861 = Miles2
In3 x 16387 = mm3 x 0.000061 = In3
Ft3 x 0.02832 = m3 x 35.31 = Ft3
Gals (Imp) x 4.546 = L x 0.22 = Gals (Imp)
Gals (Imp) x 0.004546 = m3 x 220 = Gals (Imp)
Gals (US) x 3.785 = L x 0.2642 = Gals (US)
LBS x 0.4536 = kg x 2.2046 = LBS
Tons x 1016 = kg x 0.000984 = Tons
Gal/Min (Imp) x 0.2727 = m3/h x 3.6667 = Gal/Min (Imp)
Gal/Min (Imp) x 0.0757 = L/Sec x 13.21 = Gal/Min (Imp)
L/Sec x 3.6 = m3/h x 0.277 = L/Sec
Gal/Min (Imp) x 1.2 = USGPM x 0.833 = Gal/Min (Imp)
PSI x 0.06895 = Bar x 14.504 = PSI
PSI x 0.703 S.G = M Liquid x 1.422xS.G = PSI
Ft Liquid x 0.02989xS.G = Bar x 33.456 SG = Ft Liquid
STD. ATM x 1.01225 = Bar x 0.9879 = STD. ATM
HP x 0.7457 = kW x 1.341 = HP
Conversion Factors
88
Conversion Factors
Flow Conversions
M3/min GPHUS GPM GPM
dm3/min dm3/hr L/HR
Kg/hr
Kg/sec
264 1.2 60
604.4 3.66
219.6792
60
CFM
M3/Sec
2.12
1000
1000
3.6 L/Sec
Tonne Hr
100xSG
3.6SG
0.06
1.0SG
=L/min L/min1.0 60
M3/hr
1000 100016.67
x
Head/Pressure Conversions
PSI
KN/m2
MegaPascal MPA
Kg/
14.22
14.5
1.02
10
100
k Pa
Ft
1
9.8xSG
10.211SG
33.5SG
bar
3.28
9.8xSG
M
x ÷
1.42xSG
6.9
Atmos-phere
33.9
10.34
PSI
2.31SG
÷
13.2
= dm 3/5
89
Flange Sizes
Normal Table Dia. P.C.D Bolt No. of Flange Thickness Bore Flange Dia. Bolts Grey Cast Iron
1” D&E 4.50” 3.25” .50” 4 .50”1.25” D&E 4.75” 3.44” .50” 4 .625”1.5” D 6.00” 4.50” .625” 4 .688”2” E 6.00” 4.50” .625” 4 .75050mm NP16 165mm 125mm M16 4 20mm2.5” D 6.50” 5.00” .625” 4 .688”
E 6.50” 5.00” .625” 4 .750”3” D&E 7.25” 5.75” .625” 4 .750”80mm NP10 200 (7.87) 160 (6.30) M16 8 21 (.83)
NP16 200 (7.87) 160 (6.30) M16 8 21 (.83)4” D 8.50” 7.00” .625” 4 .750”
E 8.50” 7.00” .625” 8 8.75”
100mm NP10 220 (8.66) 180 (7.09) M16 8 22 (.87)NP16 220 (8.66) 180 (7.09) M16 8 22 (.87)
5” D 10.00” 8.25” .625” 8 .813”E 10.00” 8.25” .625” 8 .875”
6” D 11.00” 9.25” .625” 8 .813”E 11.00” 9.25” .750” 8 8.75”
150mm NP10 285 (11.22) 240 (9.49) M20 8 23 (.91)N16 285 (11.22) 240 (9.49) M20 8 23 (.91)
7” D 12.00” 10.25” .625” 8 .875”E 12.00” 10.25” .750” 8 1.00”
8” D 13.25” 11.50” .675” 8 .875”E 13.25” 11.50” .750” 8 1.00”
200mm NP10 340 (12.38) 295(11.61) M20 8 245 (.96)NP16 340 (12.38) 295(11.61) M20 12 245 (.96)
9” D 14.50” 12.75” .625” 8 .875”E 14.50” 12.75” .750” 12 1.00”
10” D 16.00” 14.00” .750” 8 1.00”E 16.00” 14.00” .750” 12 1.00”
250mm NP10 400 (15.75) 350(13.78) M20 12 26 (1.02)NP16 400 (15.75) 355 (13.98) M25 12 26 (1.02)
12” D 18.00” 16.00” .750” 12 1.00”E 18.00” 1.00” .875” 12 1.125”
300mm NP10 455 (17.91) 400 (15.75) M20 12 27.5 (1.08)NP16 455 (17.91) 410 (16.14) M25 12 27.5 (1.08)
90
NP10 and NP16 are for cold water pressure of 10 bar and 16 bar and are the currentBritish Standard. They are unnecessarily heavy for most contractors’ pumps.
Thainstone Business ParkInverurieAberdeenshireAB51 5GT
Tel 01467 623010Fax 01467 623011Email [email protected]
www.filpumps.co.uk