Aichi Tokei Denki ・ Since 1983 ・ Electromagnetic T
echn
ology
・
Electromagnetic Flow Meter
WX-C/WZ-CWater maX series
For various types of fluid management such as cooling water, warm water,
treated water, process waste water, etc.
Aichi Tokei Denki ・ Since 1983 ・ Electromagnetic T
echn
ology
・
model WZ-C
model WXmodel WX-C
model WZ-CCool water and hot water management on central air conditioning
Make-up water management for cooling towers
Management of the intake amount and the treated amount of well water / river water
Management of final wasted amount of discharge
Cool water and hot water management for absorption type hot and cold water generator
For Make-up water on boiler / drain water management
Hot water managementVarious kind of industrial water / process waste water management
Management of various types of liquid in a factory or air conditioning is available.
Flow velocity/Flow rate conversion table▼Fl
ow v
eloc
ity (m
/sec
)
Flow rate (m3/h)
0.1
1
10
0.1 1.0 10.0 100.0 1000.0
φ25 21.2m
3 /h(12m/s)
φ40 54.3m
3 /h(12m/s)
φ32 34.7m
3 /h(12m/s)
φ50 84.8m
3 /h(12m/s)
φ65 143m
3 /h(12m/s)
φ80 217m
3 /h(12m/s)
φ100 339m
3 /h(12m/s)
φ125 530m
3 /h(12m/s)
φ150 763m
3 /h(12m/s)
φ200 1356m
3 /h(12m/s)
φ250 2120m
3 /h(12m/s)
φ300 3052m
3 /h(12m/s)
The electrode material can be selected from among SUS316 stainless steel (standard), titanium, Hastelloy C, and tantalum. /
Variations on display indication
Point.3
2 items can be selected from among the following 7 items, and can be indicated in two rows: top and bottom.
Supported with pulse/analog outputs as standard specificationsAs an option*, RS485 output can also be selected. *WZ-C
Various outputs signal can be selected according to use
RS485Analog
Pulse
Instantaneous flow rate
Integrated valueAccumulated trip value / Date and time / Total integrated value /
Instantaneous flow rate, and others
Depth Vertical piping
Display area that is easy to see
Entire display area
350° LCD can be turnedbbbbbbbbbbbbbbbbbbeeeeeeee e eee e ccccacacacaccacacacacccccc nn nnnnn nnnn nnn ttttttttttttttturnurnurnurnurnurnurnrnurnurnrnurnurnur eddedededededdedededededddLCDLCDLCDLCDCDLCDCDLCDLCDLCDLCDLCDLCDLCDCDLCDLCDCDLCD can be turned
90° 9999999999999999999909090909090909090909090909090009090°°°°°°°°°°°°90° rightward or leftward
Point.1
Backlight LCDPoint.2
• Total integrated value
• Reverse flow integrated value
• Integrated trip value
• Date (Day, Month, Year)/Time
• Bar graph
• Forward flow integrated value• Instantaneous flow rate
Example of item selection
Other items to be indicated
Easy to change the direction of display according to the environment of installation
Adopting fluorocarbon resin lining, selection of the electrode material is enabled.
Even in vertical piping or in a narrow and recessed place, the display can easily be checked.
The letters can be seen clearly and the settings can be changed even in a dark place.
*notice : WZ-C only
Effective for treated water and process waste water measuring/*/
Measuring electrode
Electrode for detecting not water filled condition
Electrode for grounding
Unit:mmDaiameter
LHD
2590
21571
4011023690
WX-C (wafer connection type) WZ-C (flange connection type)
H
D
L
H
D
LUnit:mm
DaiameterLHD
25200253125
40200270140
32200263135
65200315175
80200328185
100250355210
125250390250
150300418280
200350475330
250450555400
300500605445
50200295155
*1 Set value when the analog output is 20mA at the time of delivery. The setting can be changed to an arbitrary flow rate.*2 Selection can be made from among Integrated pulse, flow switch, and alarm (output 2 only). The setting of the Integrated pulse unit can be changed.*3 The communication specifications can be downloaded from our product website.*4 Power should be supplied from isolated power supply with overcurrent protection. In addition, 1 power supply unit should be connected to each flow meter.*5 Wafer = (Sandwich) by using JIS 10K flanges *6 In case installed outdoors, a lightning arrester should be installed, and direct sunlight should be avoided. Failure to observe this precaution may lead to failure of the equipment, malfunction/defective operation of the switch.
WX025C
25mm
21
0.35
5
0.26
WX040C
40mm
54
0.9
13
0.68
WZ025C
25mm
21
0.35
5
0.26
WZ032C
32mm
34
0.6
8
0.45
WZ040C
40mm
54
0.9
13
0.68
WZ050C
50mm
84
1.4
20
1.2
WZ065C
65mm
144
2.4
35
1.8
WZ080C
80mm
220
3.6
50
2.7
WZ100C
100mm
340
5.6
85
4.2
WZ125C
125mm
534
8.9
130
4.5
WZ150C
150mm
760
13
190
9.6
WZ200C
200mm
1350
23
340
18
WZ250C
250mm
2115
35
530
26.4
WZ300C
300mm
3050
51
760
38
About 4kg About 5kg About 6kg About 7kg About 8kg About 10kg About 12kg About 13kg About 20kg About 27kg About 38kg About 45kg About 66kg About 79kg
Analog
Pulse *2
Communication
Display screen
Contents of indication
Materials
Mass Weight
Temperature of the measured fluid
Temperature and humidity of the environment of use
Conductivity
Power supply *4
Power consumption
Connecting method
Operating pressure
Protection *6
Output
Indication
Type
Nominal Diameter
Maximum flow rate (m3/h)
Analog FS value (m3/h) *1
Minimum flow rate (m3/h)
Zero cut flow rate (m3/h)
Accuracy
Display part: aluminum, glassMeasuring tube: stainless steelLining: PTFE, RilsanElectrode: SUS316Ti stainless steel
2 points Open collector 48VDC/25mA ON width: 4.3ms (can be set at 1-424ms)Output 1: Integrated pulse (factory default settings 25-80mm: 100L/P, 100-300mm: 1000L/P), Output 2: alarm
(Option) 1 point RS485 Modbus/RTU *3 Communication speed: 9600bps (selectable from 1200,2400,4800,9600bps)
Display part : aluminum, glassMeasuring tube: flange, stainless steelLining : PTFE, PFA, RilsanElectrode : (Standard) SUS316Ti stainless steel, (Option) titanium, Hastelloy C, and tantalum
Flange JIS 10K
1.0MPa
16 letters × 2 rows (1 letter Dot matrix having 7 columns ×5 rows) Green backlight
(Standard indication) 1st row: Forward flow Integrated value, 2nd row: Instantaneous flow rate / Date and time / Total Integrated value / Forward flow Integrated value / Reverse flow Integrated value / Integrated trip value / Instantaneous flow rate / Bar graph
24VDC±10% (power supply current: 350mA or more)
8.4W
Wafer *5
IP65
±1.0%RD
Rilsan Lining: Not Over from 0 to +70°C PTFE/PFA Lining: Not Over from 0 to +90°C (no freezing permissible)
Between -10 and +55°C 90%RH or below (no freezing or condensation)
20μS/cm or more
1 point 4-20mA max. load: 400Ω or less
Specifications of the electromagnetic flow meters WX-C / WZ-C
Outer dimensions
To Our Customers 1.0
Technical specifications in this catalog are up-to-date as of May 2020.
202005-WX_C_WZ_C-000
Please understand that product specifications may be changed without notice in order to improve performance. We are always happy to provide the latest catalogs and brochures, and respond to inquiries made to our offices.
1-2-70 Chitose, Atsuta-ku, Nagoya, 456-8691, Japan
Manufactured and Distributed by
URL : https://www.aichitokei.net/
For inquires, please contact us.
Overseas Business Division TEL +81-(0)52-661-5150
Aichi tokei denki co.,ltd.