Upload
others
View
5
Download
0
Embed Size (px)
Citation preview
204 mm (8.03")
169 mm (6.63")
TRANSDUCER1 TRANSDUCER2
NET-3 NET-1 POWER 12V/24V 3ANET-2
91 mm(3.58")
180 mm(7.09")
57 mm (2.24")
207 mm(8.15")
183 mm (7.20")
Dimensions
MountingParts included
DESCRIPTION
1 StructureScan® 3D module
2 Installation screws
3 Ethernet cable, 4 m (15 ft)
4 Power cable, 2 m (6.6 ft)
5 Fuse and Fuse holder
6 StructureScan® 3D Transducer (Optional)
StructureScan®3DInstallation Guide
For technical specifi cations and declarations, refer to the product
website on:
*988-10970-001*
simrad-yachting.comlowrance.com
TRANSDUCER1 TRANSDUCER2
NET-3 NET-1 POWER 12V/24V 3ANET-2
TRA
NS
DU
CE
R1
TRA
NS
DU
CE
R2
NE
T-3
NE
T-1
PO
WE
R12
V/2
4V 3
AN
ET-
2
TRANSDUCER1 TRANSDUCER2
NET-3 NET-1 POWER 12V/24V 3ANET-2
TRANSDUCER1 TRANSDUCER2
NET-3 NET-1 POWER 12V/24V 3ANET-2
1 2 3 4 5 6
TRANSDUCER1 TRANSDUCER2
NET-3 NET-1 POWER 12V/24V 3ANET-2
Power
Connectors and LEDs
Wiring example
Transducer connection
TRANSDUCER1 TRANSDUCER2
NET-3 NET-1 POWER 12V/24V 3ANET-2
TRANSDUCER1 TRANSDUCER2
NET-3 NET-1 POWER 12V/24V 3ANET-2
Switch
12 / 24 V DC
+ _
Red
Black
Yellow
Blue(n/c)
Blue(n/c) Blue
(n/c)
RedBlack
Yellow Red
Black
Yellow
+ _Power
Control bus
To Multi-FunctionDisplay
12 / 24 V DC
12
3 3
TRANSDUCER1 TRANSDUCER2
NET-3 NET-1 POWER 12V/24V 3ANET-2
ID CONNECTORS LEDs
1 EthernetOFF No connection
ON/FLASHING - Green Connected and ok
2 Power
OFF No power
ON - Red System starting
ON - Green System operating
FLASHING Red/Green Software error - restart unit
3Structure Scan
3D transducer
OFF Sounder not operating
FLASHING (every second) - Green
Searching for bottom signal
ON Operational system with bottom signal detected
Power controlled by External Switch Power controlled by Multi-Function Display
12/24 V DCStructureScan® 3D Module
StructureScan® 3D Transducer
StructureScan® 3D Transducer cable 1
to
Transducer 1 Connector
StructureScan® 3D Transducer cable 2
to
Transducer 2 Connector
4G RadarMulti-Function Displays
TRANSDUCER1 TRANSDUCER2
NET-3 NET-1 POWER 12V/24V 3ANET-2
Ensure both StructureScan® 3D transducer cables are connected to the StructureScan® 3D Module correctly