Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
1
NTSVICINITY MAP
AUSTIN KOREANFOR
CIVIL SITE DEVELOPMENT PLANS
PRESBYTERIAN CHURCH12311 NATURES BENDAUSTIN, TEXAS 78753
JULY 2014
CIV
IL C
ON
STR
UC
TIO
N P
LAN
SA
US
TIN
KO
RE
AN
PR
ES
BY
TER
IAN
CH
UR
CH
KH
A P
RO
JEC
T N
O. 0
6924
1500
AU
STI
N K
OR
EA
NP
RE
SB
YTE
RIA
N C
HU
RC
HC
ITY
OF
AU
STI
NTR
AV
IS C
OU
NTY
, TE
XA
S
©
BENCHMARKSTBM #1: 1/2" REBAR WITH PLASTIC "CHAPARRALRANDOM" CAP SET +/- 245' EAST OF THE SOUTHWESTCORNER OF THE 6.320 ACRE TRACT AND +/- 258' WESTOF THE SOUTHEAST CORNER OF THE 6.320 ACRETRACT.
ELEVATION = 671.78'VERTICAL DATUM: NAVD 88 (GEOID 09)
TBM #2: SQUARE IN CONCRETE OF BOTTOM STEP OFSERVICE STAIRS FOR TELEPHONE UTILITIES +/- 15'NORTH OF THE NORTH EDGE OF ASPHALT OF YAGERLANE.
ELEVATION = 677.61'VERTICAL DATUM: NAVD 88 (GEOID 09)
WARNING: CONTRACTORIS TO VERIFY PRESENCE AND
EXACT LOCATION OF ALLUTILITIES PRIOR TO
CONSTRUCTION AND NOTIFYENGINEER OF ANY DISCREPANCIES.
SITE PLAN APPROVAL SHEET ____OF____FILE NUMBER__________________APPLICATION DATE_______________APPROVED BY COMMISSION ON_______________UNDER SECTION_______ OFCHAPTER__________OF THE CITY OF AUSTIN CODE.EXPIRATION DATE (25-5-81,LDC)_______________CASE MANAGER_____________PROJECT EXPIRATION DATE (ORD.#970905-A)__________DWPZ______DDZ______
__________________________________________________________________________Director, Planning and Development ReviewRELEASED FOR GENERAL COMPLIANCE:_____________ZONING_____________Rev. 1____________________________Correction 1_____________________________Rev. 2____________________________Correction 2_____________________________Rev. 3____________________________Correction 3_____________________________Final plat must be recorded by the Project Expiration Date, if applicable. Subsequent Site Planswhich do not comply with the Code current at the time of filing, and all required BuildingPermits and/or a notice of construction (if a building permit is not required), must also beapproved prior to the Project Expiration Date.
SP-2014-0084C
of 29
PRESSURE ZONE AREA: NORTHWATERSHED: WALNUT CREEK WATERSHED (SUBURBAN)ZONING: LR & LOSUBDIVISION CASE NO.: C8-2014-0012.0A
No. DESCRIPTION
CORRECTIONS
SHEET No'S
DELETE (D)REVISE (R)
ADD (A) IMPERV.IN PLANSET COVER
SHEETSTOTAL
CHANGENET
APPROVALDATECOVER COVER
IMP.IMPERV.SITE %
GENERAL PLAN NOTES:
1. RELEASE OF THIS APPLICATION DOES NOT CONSTITUTE A VERIFICATION OF ALL DATA, INFORMATION AND CALCULATIONSSUPPLIED BY THE APPLICANT. THE ENGINEER OF RECORD IS SOLELY RESPONSIBLE FOR THE COMPLETENESS, ACCURACY ANDADEQUACY OF HIS/HER SUBMITTAL, WHETHER OR NOT THE APPLICATION IS REVIEWED FOR CODE COMPLIANCE BY CITYENGINEERS.
2. THERE ARE NATURAL SLOPES ON THIS SITE IN EXCESS OF 15%.
3. NO STRUCTURES CAN BE BUILT WITHIN WATER & WASTEWATER EASEMENTS.
4. AS PART OF THIS SITE PLAN, THE STORM WATER POLLUTION PREVENTION PLAN (SWPPP) IS REQUIRED TO BE ON SITE AT ALLTIMES.
5. THIS SITE PLAN IS SUBJECT TO SUBCHAPTER E OF THE LAND DEVELOPMENT CODE (COMMERCIAL DESIGN STANDARDS).
FLOODPLAIN: NO PORTION OF THIS TRACT IS WITHIN THE BOUNDARIES OF THE 100 YEAR FLOOD OF A WATERWAY THAT IS WITHIN THEFEDERAL EMERGENCY MANAGEMENT AGENCY, NATIONAL FLOOD INSURANCE PROGRAM, AS SHOWN ON MAP NO. 48453C0270H, DATEDSEPTEMBER 26, 2008, FOR TRAVIS COUNTY, TEXAS AND INCORPORATED AREAS.LEGAL DESCRIPTION: 6.320 ACRES IN THE J.A.G. BROOKE SURVEY NO. 79, ABSTRACT NO. 69, TRAVIS COUNTY, TEXAS, CONVEYED BY DEED OF RECORDIN DOCUMENT NO. 2005241340 OF THE OFFICIAL PUBLIC RECORDS OF TRAVIS COUNTY, TEXAS, 19.854 ACRES IN THE J.A.G. BROOKE SURVEY NO. 79,ABSTRACT NO. 69, TRAVIS COUNTY, TEXAS, CONVEYED BY DEED OF RECORD IN DOCUMENT NO. 2005241338 OF THE OFFICIAL PUBLIC RECORDS OFTRAVIS COUNTY, TEXAS AND A 0.664 ACRE PORTION OF LOT 63A, BLOCK B, THE SPRINGS OF WALNUT CREEK PHASE II, A SUBDIVISION OF RECORD INDOCUMENT NO. 201100003 OF THE OFFICIAL PUBLIC RECORDS OF TRAVIS COUNTY, TEXAS AND CONVEYED BY DEED OF RECORD IN DOCUMENT NO.2012024537 OF THE OFFICIAL PUBLIC RECORDS OF TRAVIS COUNTY, TEXAS. THIS IS PENDING RECORDATION OF THE FINAL PLAT.
GASTEXAS GAS SERVICELINDA BARGAR5613 AVENUE FAUSTIN, TX 78751PH. (512) [email protected]
WATER & SANITARY SEWERAUSTIN WATER UTILITYGEORGE RESENDEZ625 E. 10TH STREET, SUITE 715AUSTIN, TX 78701PH. (512) 972-0207
STORM SEWERCITY OF AUSTINPLANNING & DEVELOPMENTREVIEW DEPARTMENT505 BARTON SPRINGS ROADAUSTIN, TX 78704PH. (512) 974-2680
LIST OF CONTACTS:
OWNERAUSTIN KOREANPRESBYTERIAN CHURCHROY KIM2000 JUSTIN LANEAUSTIN, TX 78750PH. (512) 689-9583
FIREAUSTIN FIRE DEPARTMENTRALPH CASTILLOONE TEXAS CENTER SUITE 200505 BARTON SPRINGS ROADAUSTIN, TX 78704PH. (512) 974-0192
TELEPHONEAT&TDAVID A. WILLIAMS712 EAST HUNTLAND, ROOM 229AUSTIN, TX 78752PH. (512) [email protected]
SURVEYORCHAPARRAL PROFESSIONALLAND SURVEYING, INC.ROBERT C. WATTS, JR.3500 MCCALL LANEAUSTIN, TX 78744PH. (512) 443-1724
ARCHITECTARCHI DESIGN BUILDSAMUEL KIM11393 HARRY HINES BLVD., SUITE DDALLAS, TEXAS 75229PH. (972) 484-4415
AUSTIN, TEXAS 7875910415 MORADO CIRCLE, BUILDING I, SUITE 300 Tel. No.
Fax No.(512) 418-1771(512) 418-1791
CERTIFICATE OF REGISTRATION #928
PREPARED BY:
I CERTIFY THAT THESE ENGINEERING DOCUMENTS ARE COMPLETE, ACCURATE AND ADEQUATE FOR THE INTENDED PURPOSES, INCLUDING CONSTRUCTION, BUT ARE NOT
VERIFICATION OF ALL DATA, INFORMATION AND CALCULATIONSRELEASE OF THIS APPLICATION DOES NOT CONSTITUTE A
SUPPLIED BY THE APPLICANT. THE ENGINEER OF RECORDIS SOLELY RESPONSIBLE FOR THE COMPLETENESS, ACCURACY,
NOTE:
NOTE:
AUTHORIZED FOR CONSTRUCTION PRIOR TO FORMAL CITYAPPROVAL.
AND ADEQUACY OF HIS/HER SUBMITTAL, WHETHER OR NOTTHE APPLICATION IS REVIEWED FOR CODE COMPLIANCE BYCITY ENGINEERS.
CITY OF AUSTIN PLANNING AND DEVELOPMENT REVIEW DEPARTMENT
AUSTIN WATER UTILITY
DATE
DATE
INDUSTRIAL WASTE DATE
AUSTIN FIRE DEPARTMENT
DATE
INDEX OF SHEETS
Sheet Number Sheet Title
1 COVER SHEET2 RE-PLAT (SHEET 1 OF 2)3 RE-PLAT (SHEET 2 OF 2)4 GENERAL NOTES5 SLOPE MAP6 SITE PLAN
7 GRADING & PAVING PLAN
8 PAVING & STRIPING PLAN9 DRAINAGE AREA MAP - PRE DEVELOPMENT
10 DRAINAGE AREA MAP (POST DEVELOPMENT)
11WATER QUALITY AND DETENTION POND A
12WATER QUALITY AND DETENTION POND B
13 WATER QUALITY AND DETENTION DETAILS14 UTILITY PLAN15 EROSION AND SEDIMENTATION CONTROL PLAN16 EROSION AND SEDIMENTATION CONTROL PLAN17 EROSION & TREE PROTECTION DETAILS18 LANDSCAPE PLAN - 1 OF 219 LANDSCAPE PLAN - 2 OF 220 LANDSCAPE PLAN - TREE SURVEY LIST21 UTILITY DETAILS (1 OF 3)
22 UTILITY DETAIL (2 OF 3)
23 UTILITY DETAILS (3 OF 3)24 PAVING & STORM DRAIN DETAILS25 PAVING DETAILS26 SIDEWALK DETAILS27 TRAFFIC CONTROL DETAILS (1 OF 2)28 TRAFFIC CONTROL DETAILS (2 OF 2)29 BUILDING ELEVATION SHEET
CO
VE
R S
HE
ET
“ ”
“ ”
PRIVATE FIRE HYDRANT NOTES:
THIS PROJECT HAS TWO (2) PRIVATE HYDRANTS LOCATED WITHINTHE PROPERTY. THE PROPERTY OWNER IS REQUIRED TO COMPLYWITH AUSTIN FIRE CODE. FAILURE TO COMPLY MAY RESULT INCIVIL AND/OR CRIMINAL REMEDIES AVAILABLE TO THE CITY.THE PERFORMANCE OF THIS OBLIGATION SHALL ALWAYS RESTWITH THE OWNER OF RECORD. FIRE HYDRANTS ON PRIVATEPROPERTY ARE REQUIRED TO BE SERVICED, MAINTAINED ANDFLOWED ANNUALLY, USING A CONTRACTOR REGISTERED WITHTHE CITY TO PROVIDE THE SERVICE.
AN ADMINISTRATIVE VARIANCE WAS GRANTED PER LDC25-8-42(B)(5) OF THE LDC FOR CUT/FILL UP TO 8 FEET ASSOCIATEDWITH THE WATER QUALITY AND/OR DETENTION POND A.
IMPERVIOUS COVERAGE: 13.5%FLOOR AREA RATIO: 0.037:1
LAND DEVELOPMENT NOTE:THIS SITE PLAN IS SUBJECT TO SUBCHAPTER "E"OF THE LAND DEVELOPMENT CODE (COMMERCIALDESIGN STANDARDS.)
1st SUBMITTAL DATE: FEBRUARY 19, 2013
SIT
E P
LAN
6
AU
STI
N K
OR
EA
NP
RE
SB
YTE
RIA
N C
HU
RC
HC
ITY
OF
AU
STI
NTR
AV
IS C
OU
NTY
, TE
XA
S
©
BENCHMARKSTBM #1: 1/2" REBAR WITH PLASTIC "CHAPARRALRANDOM" CAP SET +/- 245' EAST OF THE SOUTHWESTCORNER OF THE 6.320 ACRE TRACT AND +/- 258' WESTOF THE SOUTHEAST CORNER OF THE 6.320 ACRETRACT.
ELEVATION = 671.78'VERTICAL DATUM: NAVD 88 (GEOID 09)
TBM #2: SQUARE IN CONCRETE OF BOTTOM STEP OFSERVICE STAIRS FOR TELEPHONE UTILITIES +/- 15'NORTH OF THE NORTH EDGE OF ASPHALT OF YAGERLANE.
ELEVATION = 677.61'VERTICAL DATUM: NAVD 88 (GEOID 09)
WARNING: CONTRACTORIS TO VERIFY PRESENCE AND
EXACT LOCATION OF ALLUTILITIES PRIOR TO
CONSTRUCTION AND NOTIFYENGINEER OF ANY DISCREPANCIES.
SITE PLAN APPROVAL SHEET ____OF____FILE NUMBER__________________APPLICATION DATE_______________APPROVED BY COMMISSION ON_______________UNDER SECTION_______ OFCHAPTER__________OF THE CITY OF AUSTIN CODE.EXPIRATION DATE (25-5-81,LDC)_______________CASE MANAGER_____________PROJECT EXPIRATION DATE (ORD.#970905-A)__________DWPZ______DDZ______
__________________________________________________________________________Director, Planning and Development ReviewRELEASED FOR GENERAL COMPLIANCE:_____________ZONING_____________Rev. 1____________________________Correction 1_____________________________Rev. 2____________________________Correction 2_____________________________Rev. 3____________________________Correction 3_____________________________Final plat must be recorded by the Project Expiration Date, if applicable. Subsequent Site Planswhich do not comply with the Code current at the time of filing, and all required BuildingPermits and/or a notice of construction (if a building permit is not required), must also beapproved prior to the Project Expiration Date.
SP-2014-0084C
of 29
00 60' 120'
GRAPHIC SCALE 60'
UTI
LITY
PLA
N
14
AU
STI
N K
OR
EA
NP
RE
SB
YTE
RIA
N C
HU
RC
HC
ITY
OF
AU
STI
NTR
AV
IS C
OU
NTY
, TE
XA
S
©
WARNING: CONTRACTORIS TO VERIFY PRESENCE AND
EXACT LOCATION OF ALLUTILITIES PRIOR TO
CONSTRUCTION AND NOTIFYENGINEER OF ANY DISCREPANCIES.
SITE PLAN APPROVAL SHEET ____OF____FILE NUMBER__________________APPLICATION DATE_______________APPROVED BY COMMISSION ON_______________UNDER SECTION_______ OFCHAPTER__________OF THE CITY OF AUSTIN CODE.EXPIRATION DATE (25-5-81,LDC)_______________CASE MANAGER_____________PROJECT EXPIRATION DATE (ORD.#970905-A)__________DWPZ______DDZ______
__________________________________________________________________________Director, Planning and Development ReviewRELEASED FOR GENERAL COMPLIANCE:_____________ZONING_____________Rev. 1____________________________Correction 1_____________________________Rev. 2____________________________Correction 2_____________________________Rev. 3____________________________Correction 3_____________________________Final plat must be recorded by the Project Expiration Date, if applicable. Subsequent Site Planswhich do not comply with the Code current at the time of filing, and all required BuildingPermits and/or a notice of construction (if a building permit is not required), must also beapproved prior to the Project Expiration Date.
SP-2014-0084C
of 29
PROPERTY LINE
PROPOSED SANITARY SEWER LINE
PROPOSED WATER LINE
PROPOSED SANITARY SEWER MANHOLE
PROPOSED SANITARY SEWER CLEANOUT
SANITARY SEWER FLOW DIRECTION
PROPOSED FIRE HYDRANT
PROPOSED TAPPING SLEEVE & VALVE
IRRIGATION SLEEVE
EXISTING OVERHEAD POWER LINE
EXISTING WATER LINE
EXISTING SANITARY SEWER LINE
EXISTING STORM SEWER LINE
EXISTING POWER POLE
EXISTING FIRE HYDRANT
EXISTING WATER METER
EXISTING SANITARY SEWER MANHOLE
UTILITY LEGEND
00 60' 120'
GRAPHIC SCALE 60'