SPECIFICATIONS
RX16FT-ISFlush Mount Lift Rack
RX16FT-IS Shown
Form 6492-T, 06-15Supersedes Form 6492-T, 08-13a
Copyright © 2015, Hunter Engineering Company
For local contact visit:www.hunter.com/contact-hunter
For general inquiries visit:www.hunter.com
or call800-448-6848
MODEL FEATURES / DIMENSIONS
Continued on Page 2
W1
H1
H2
L
W2 R
Features FT-IS
9000-lb Swing Air Jacks (2)
Two-Speed Lowering
Dimension
Outside Width (W1) 92.5 in.2350 mm
Inside Width (W2) 40 in.1016 mm
Length (L) 231.375 in.5877 mm
Runway Width (R) 26 in.660 mm
Raised Height (H1) 72 in.1829 mm
Depth (H2) 14.75 to 15.25 in.375 to 387 mm
Site SpecificationsSubstructure Requirements Refer to 6367-T for full detailsPower Requirements 208-230 VAC, single phase power, 26 Amp
Air Supply Requirements 90-150 PSI (6.2-10.3 bar)Jacks require 125 PSI (8.6 bar) for full capacity
Minimum Concrete Spec. 3 in. (76 mm) thick, 3000 PSI (20,700kPA) ratingMaximum Floor Slope 2 in. (51 mm) over 126 in. (3200 mm)
Product SpecificationsMax. Vehicle Weight 16,000 lbs. (7257 kg)
Max. Wheelbase General Service 187 in. (4750 mm) Two-Wheel Alignment 182 in. (4623 mm) Four-Wheel Alignment 158 in. (4013 mm)Alignment Height All lock positionsMin. Four-Wheel Alignment 88 in. (2235 mm)Lifting Speed 1 speed 60 secondsLowering Speed 2 speed, 25 seconds
For lift rack information visit:www.hunter.com/lift-racks
SPECIFICATIONS (Refer to 6367-T for substructure construction requirements)
RX16FT-ISFlush Mount Lift Rack
Form 6492-T, 06-15Supersedes Form 6492-T, 08-13a
Copyright © 2015, Hunter Engineering Company
*Non-standard positioning of control console is limited to a maximum space between console and rack of 6 feet (1829 mm) at the approach ramp end and 17 feet (5182 mm) at the turnplate end. Additional threshold and perhaps hydraulic hoses will be required (refer to Installation Instruction for details)..
All dimensions shown are for finished pit. Accomodate tile thickness as needed.
! WARNING
!WARNING
!WARNING
!WARNING
DRAINLOCATED
INCENTEROF PIT
SLOPEPIT
FLOORTOWARD
DRAIN(1/2)
CONSOLE CONDUIT DETAIL
96 1/2"(2451 mm)
! WARNINGSTAY BEHINDYELLOW LINE
WHEN THELIFT MOVES.
128-978-2
DECAL 128-978-2
OPTIONAL CONSOLELOCATION
(4 places on edging and 2 places on lift)
41 3/8"(1051 mm)
141 3/4"(3600 mm)
14"(356 mm)
APPROX. 2" (51 mm) TYPICAL
14"(356 mm)
5"(127 mm)
5"(127 mm)
14" X 5"CUTOUT(4 places)
ANGLE AROUND PITPERIMETER:
- not around- painted safety yellow
- not supplied by Hunter
14" X 5" cutouts
16"(406mm)
22"(559 mm)
6" MIN.*152 mm( )
OPTIONAL 1 1/2 IN. DIA. CONDUITFOR COMMUNICATION CABLE
TO ALIGNMENT CONSOLE
HAWKEYE SERIES SENSORSAND PRONTO SYSTEMS HAVE
SPACE REQUIREMENTS INFRONT OF LIFT THAT MUST BEMET, REFER TO APPROPRIATE
SITE REQUIREMENTS.
ENTIRE PIT(BOTTOM AND WALLS)
MUST BE HARDTROWEL FINISH
FILLERPLATE
51-2308-1(4 places)
(placed over14" X 5"cutout)
34 3/4"(883 mm) EXTENDER
PLATES51-2464-1-PPP
ANDRAMPS
147-141-1-PPP
RAMPS147-141-1-PPP
231 3/8"(5877 mm)
64"(1626 mm)
33 3/4(857 mm)
OPTIONAL REAR STEP(6" (152 mm) MAX. HT.)
32"(813 mm)
PIT DEPTH OF14 3/4" to 15 1/4"
(375 mm to 387 mm)REQUIRED AT
FRONT END OF PIT
OPT. FRONT STEP(12" (305 mm)MAX. DEPTH)
* LONGER VEHICLES WILL NEED TO BE SERVICED WITH BAY DOOR OPEN. TOACCOMMODATE MOST VEHICLES, INCREASE SPACE BEHIND PIT TO ( ) ORGREATER.
39" 991 mm** SITES WITH D.R.W. TRUCKTRAFFIC SHOULD USE 20" MIN.CONSOLE TO PIT DISTANCE.
**15" TO 41"
(381 TO 1041 mm)
BAY DOOR BAY DOOR
45
6" MIN.RADIUS CONDUIT
EXIT FLUSHWITH
PIT FLOOR
ROUTE 4" MIN DIAMETERCONDUIT OR EQUIVALENTCLOSED CHANNEL FROMPIT FLOOR TO BASE OF
CONSOLE
VEHICLE APPROACH