2
8812 Frey Road, Houston TX 77034 P (713) 943-9927 F (713) 943-2818 www.xtralight.com [email protected] APPLICATION • Economical Fluorescent High Bay F32 T8 alternative to HID lighting. • Suitable for industrial open area, stack aisle retail and warehouse lighting. • Hanging options include single pendant, chain and adjustable cable. CONSTRUCTION • Top access vented ballast channel is code gauge steel painted white. • Lampholder assembly is riveted to channel for strength and rigidity. • Reflector choices are high reflectance white or enhanced code gauge aluminum. • Replaceable reflectors for ease of future maintenance. • No tools necessary for bottom ballast access. • Up-light slot option provides ceiling illumination. ELECTRICAL • Quality name brand Class P, HPF electronic ballasts. • Rotating camlock lampholders, easy to change for future maintenance. • Occupancy sensors and emergency options. • U.L. listed damp location. • High Ballast Factor Input for 8-lamp T8 = 288 watts with 277 volt driver. FEATURES • Instant restrike • Vented ballast chamber • Lower component replacement cost • No color shift • Improved uniform illumination • Uplight Options at 5% and 12% • 480 Volt option • Dimming, occupancy sensor and emergency options available • Improved lumen maintenance • Field replaceable reflectors • Ease of socket replacement ORDER LOGIC PROJECT INFORMATION Project Name Catalog # Type Date CUT SHEET: FLUORESCENT INDUSTRIAL HIGH BAY T8 FLUORESCENT INDUSTRIAL HIGH BAY T8 Refer to options terminology matrix for additional options. NC 07/10/11 4 - 4 ft. 32 4 FIH N 04 06 08 Length # Lamps M - Enhanced alum. W - White alum. Reflector Material 6 - 6 ft. 8 - 8 ft. 1 - 12 ft. X - None Cord Length G - Adjustable cable system (2) Y - Y hangers (2) X - None Mounting 1 - Aisle, multi-volt 120 - 277 2 - Open area, multi-volt 120 - 277 3 - Aisle 480 line voltage 4 - Open area 480 line voltage X - None Occupancy Sensors 8 - (1) F54, 90 min. X - None Emergency Battery Backup F - Fuse L - Lamps installed W - Whip 48G - 480v Transformer Special Options N - Normal S - Spread Beam Spread UPR - Universal Programmed Rapid Start 4RN - 480v Rapid Start Ballast A - 120v 15 amp straight-blade B - 277v 20 amp twistlock C - 480v 20 amp twistlock D - 277v 15 amp twistlock F - 120v 15 amp twistlock X - None Nema Plug XX - None Shielding 022 - (2) 2 lamp 004 - (1) 4 lamp 033 - (2) 3 lamp 024 - (1) 2 lamp, (1) 4 lamp 042 - (4) 2 lamp 044 - (2) 4 lamp Ballast Configuration 5 - Slots @ 5% 2 - Slots @ 12% X - None Uplight

Fluorescent Industrial High Bay T8 (CL052412)

Embed Size (px)

DESCRIPTION

 

Citation preview

Page 1: Fluorescent Industrial High Bay T8 (CL052412)

8812 Frey Road, Houston TX 77034 P (713) 943-9927 F (713) 943-2818 www.xtralight.com [email protected]

ApplicAtion • EconomicalFluorescentHighBayF32T8 alternativetoHIDlighting.

• Suitableforindustrialopenarea,stackaisle retailandwarehouselighting.

• Hangingoptionsincludesinglependant, chainandadjustablecable.

construction • Topaccessventedballastchanneliscode gaugesteelpaintedwhite.

• Lampholderassemblyisrivetedtochannel forstrengthandrigidity.

• Reflectorchoicesarehighreflectancewhite orenhancedcodegaugealuminum.

• Replaceablereflectorsforeaseoffuture maintenance.

• Notoolsnecessaryforbottomballastaccess.

• Up-lightslotoptionprovidesceiling illumination.

ElEctricAl • QualitynamebrandClassP,HPFelectronic ballasts.

• Rotatingcamlocklampholders,easyto changeforfuturemaintenance.

• Occupancysensorsandemergencyoptions.

• U.L.listeddamplocation.

• HighBallastFactorInputfor8-lampT8=288 wattswith277voltdriver.

fEAturEs

• Instantrestrike

• Ventedballastchamber

• Lowercomponent replacementcost

• Nocolorshift

• Improveduniformillumination

• UplightOptionsat5%and12%

• 480Voltoption

• Dimming,occupancysensor andemergencyoptions available

• Improvedlumenmaintenance

• Fieldreplaceablereflectors

• Easeofsocketreplacement

ordEr logic

Project InformatIon

Project Name

Catalog #

Type

Date

cut shEEt: fluorEscEnt industriAl high BAY t8

fluorEscEnt industriAl high BAY t8

Refertooptionsterminologymatrixforadditionaloptions.

NC 07/10/11

4 - 4 ft.

324FIH N

04 0608

Length # Lamps

M - Enhanced alum.W - White alum.

Reflector Material

6 - 6 ft.8 - 8 ft.1 - 12 ft.X - None

Cord Length

G - Adjustable cable system (2)Y - Y hangers (2)X - None

Mounting

1 - Aisle, multi-volt 120 - 2772 - Open area, multi-volt 120 - 2773 - Aisle 480 line voltage4 - Open area 480 line voltageX - None

Occupancy Sensors

8 - (1) F54, 90 min.X - None

Emergency Battery Backup

F - FuseL - Lamps installedW - Whip48G - 480v Transformer

Special Options

N - NormalS - Spread

Beam Spread

UPR - UniversalProgrammed Rapid Start4RN - 480v Rapid Start

Ballast

A - 120v 15 amp straight-bladeB - 277v 20 amp twistlockC - 480v 20 amp twistlockD - 277v 15 amp twistlockF - 120v 15 amp twistlockX - None

Nema Plug

XX - None

Shielding022 - (2) 2 lamp004 - (1) 4 lamp033 - (2) 3 lamp024 - (1) 2 lamp, (1) 4 lamp042 - (4) 2 lamp044 - (2) 4 lamp

Ballast Configuration

5 - Slots @ 5%2 - Slots @ 12%X - None

Uplight

Page 2: Fluorescent Industrial High Bay T8 (CL052412)

8812 Frey Road, Houston, TX 77034 P (713) 943-9927 F (713) 943-2818 www.xtralight.com [email protected]

xtralight.com

fluorEscEnt industriAl high BAY t8

dimEnsionAl dAtA

photomEtric dAtA

fIH-4-04-32 normal BeamSpacing Criteria = 1.15

Efficiency = 91%

fIH-4-04-32 Spread BeamSpacing Criteria = 1.8

Efficiency = 89%

fIH-4-06-32 normal BeamSpacing Criteria = 1.1

Efficiency = 91%

fIH-4-06-32 Spread BeamSpacing Criteria = 1.8

Efficiency = 89%FIH_T8

4769

3577

2385

1132

3549

2561

1774

887

7254

5441

3827

1814

5193

3894

2596

1258

QuicK rEfErEncE guidE

Spacing 50’ high 42 23 15 55 30 19 62 34 21 82 46 29 40’ high 43 24 16 56 31 20 64 35 23 84 47 30 30’ high 44 25 17 58 33 21 66 36 24 86 49 31 20’ high 45 26 16* 59 34 19* 68 39 25* 89 51 32*

FiH 4X32 T8 normal, 112 W15 20 25

.88 BF

FiH 4X32 T8 High, 143 W15 20 25

1.15 BF

FiH 6X32 T8 normal, 160 W15 20 25

.88 BF

FiH 6X32 T8 High, 220 W15 20 25

1.15 BF

*Calculations based on Spread Beam Optics, others based on Normal Beam Optics. Actual results may vary.Additional layouts available upon request. Quick reference chart based on IH Enhanced Aluminum Optics, without Up-Light or lens. @ 2.5 ft. AFF

cut shEEt: fluorEscEnt industriAl high BAY t8

Bottom View

end View4-lamp=12”6-lamp=18”8-lamp=24”10-lamp=31”

Side ViewBallastchannelventing

31/4”

Bottom access View with Sensortop access View (without Sensor)

13/4”

4-lamp=203/4”

6-lamp=273/4”cross Section Width

A=18”

B=24”AccessBoxOption

C=51/2”Wiringaccessphoto

D=12”cablechainhanging

E=7/9”[email protected]