2
fLumo LB 500 Luminescence PET Detector * Highly sensive detector Background-free Gamma and PET Monitoring Various cell sizes detect and identify www.berthold.com/bio fLumo LB 500 Luminescence PET Detector * detect and identify www.berthold.com/bio

fLumo LB 500 - berthold-us.com€¦ · detect and identify fLumo LB 500 Luminescence PET Detector Flow Monitoring Chemiluminescence and Gamma Isotopes in High Background Labs

  • Upload
    vodieu

  • View
    215

  • Download
    1

Embed Size (px)

Citation preview

fLumo LB 500Luminescence PET Detector *

• Highlysensitivedetector• Background-freeGammaandPETMonitoring• Variouscellsizes

detect and identify

w w w . b e r t h o l d . c o m / b i o

fLumo LB 500Luminescence PET Detector *

detect and identify

w w w . b e r t h o l d . c o m / b i o

detect and identify

w w w . b e r t h o l d . c o m / b i o

fLumo LB 500Luminescence PET Detector

FlowMonitoringChemiluminescenceandGammaIsotopesinHighBackgroundLabsThefLumoChemiluminescenceDetectorforHPLCandliquidchromatographysystemsusesahighlysensitivehead-onphotoncountingdetectorwithlowbackground.Differentcellsizescanbeusedtoadaptforflowratesandsignalintensities.Thecompatibilityoftheevalua-tionelectronicstoexternalanalysissystemsisguaranteed.

HighlySensitiveLuminescenceMonitoringDuetothelow-noisehead-onPMTdesignedtofacethesamplecoilinadirectwaymakesthefLumoanutmostsensitivedetectorforfain-testtracesofchemiluminescencesignals.

Background-freeGammaandPETMonitoringTheuseofspecificmeasuringcellsmakesthemeasurementofhighactivitygammaemittingistopesaseasyascanbeeveninahighback-groundlaboratory.

OperationModeThesystemcanbeusedeitherina„standalonemode“,orbeconnectedtoaPC.ThefLumosystemisequippedwithaflashmemoryanda24MHzCPU.Thisallowsimmediatedataprocessingandeasyupgrading.

MultipleOutputsTheuserhastheoptionofusingtheanalogueoutput,theTTLsignalorthedigitaloutputthroughthePC-software.

DownstreamControlTwothresholdlevelscanbesetinthefLumosystemwhichcanbeusedtoactivate,e.g.solenoidvalves.

AdriverforChromeleon®andRadioStarisavailable.Documentationforinstrumentcommunicationisavailableonrequest.

Specificationandorderinformation DetectionDevice lownoisephotoncountingPMTDetectionMode luminescence gammaandPETisotopesMax.countrate 4millioncounts/secLinearity r2>0.995Background ~10countsDigitalInterface miniUSBAnalogOutput TTL 0to1V(10Hzsamplingrate)Regulations CEFlowCells CellTypesAdmixturecells(Ztype) Solidscint.lowbackgroundgamma/PETcells(MXtype)CellVolumes 10to1000µLOrdernumber 35144-03(withHERMelectronics,withoutcell) 58785(detecoronly,withoutcell)

detect and identify

w w w . b e r t h o l d . c o m / b i o