Copyright (c) 2012 FLOWTECH Co., Ltd. All Rights Reserved. 1
LEADING TECHNOLOGY
FLOWTECH CO., Ltd.
Sang Kim Managing Director
2005. 07 Established FLOWTECH CO,. LTD 2006. 12 Acquired a Certification of ISO 9001 & 14001 2007. 05 Acquired a Venture Enterprise Certification 2007. 05 Selected as PM(Patent Map) company by the InCheon chamber of commerce & Industry Knowledge Asset Center 2008. 08 Acquired an INNO-BIZ certificate 2009. 01 Acquired a venture ethical management certificate, Registered officially Company R&D center 2009. 07 Selected as promising SME by InCheon City
- 2 -
1. Corporation profile
1. Heritage
http://www.flowtech21.co.kr
2010. 08 Completed the biggest Eco-control System in the world(PaJu Cogeneration Plant, 180m³] 2011. 06 Accepted the business of city of eco innovation by Incheon [2011 Publish the sustainable report] 2011. 10 Selected a VISION Company and Excellent Quality products by InCheon city 2012. 04 Performance certified by Small Business Administration, Green Technology certified & Procurement Excellent Product by Ministry of Land, Transport & Maritime Affairs
- 2 -
1. Corporation profile
1. Heritage
http://www.flowtech21.co.kr
- 3 -
2. Necessity of peristaltic pump Surge Protection system
http://www.flowtech21.co.kr
1. Lack of the reliability as a safety device(continually using
20 year old technology)
3. Need to reduce the unstable waiting time after the pump
operation.
2. Need the high efficiency because of excessive consumption
energy
4. Meet the demand of stability by increasing a plant.
Develop the type of high reliability & Energy Saving Surge(Water Hammer) Protection system
3-1. Definition of Water Hammer & Occurrence factor
- 4 -
Beginning of stationary flow state in
piping system
Node demands - reservoir and tank levels
Node heads - pipe flows Pump heads and flows
Change of flow
Valve opening and closing Change in pump speed
Pump trip Change in flow demand
Hydrant opening or closing Change in reservoir head
Change of condition by transient
Phenomenon Pressure and flow variations
Effects of cavitation Effects of surge control
The final goal in the analysis of pipe flow and Water Hammer system is
stationary flow state
초기 정상류 ------- 과도한 압력변화 ------ 최종 안정화
Definition of Water Hammer When a valve in piping is opened or closed suddenly or when there is a drastic fluctuation in the flow upon operating or stopping the pump, the pressure fluctuates, and the flow also changes abruptly which is called Water Hammer phenomenon.
http://www.flowtech21.co.kr
3-2. Cause of Shockwave1 : Pump Trip by black out
- 5 -
Water Column Separation reaggregates,it makes shock such as noise and vibration
http://www.flowtech21.co.kr
In case of black-out/artificial pump sudden stop, it will make column separation of outlet pump due to procedure of fluid inertial force.
- 6 -
3-3. Damage by Water Hammer
Due to pressure rising in the pipeline, it damages facilities such as pumps, valves,pipes and etc.
Vapor cavities causes collapse or heavy shock wave generated in the course of column separation and subsequent causes break of the pipeline.
A cause of vibration and noise.
Due to abnormal pressure wave, it lose control of pressure control equipment including automatic control unit.
http://www.flowtech21.co.kr
- 7 -
3-4. Damage by Water hammer
http://www.flowtech21.co.kr
- 8 -
3-5. Flow in pipeline by pump trip
Steady state
RUN
Normal operation
Pump trip
Flow reversal
Collapse Vapor cavity
STOP
Pressure Spike STOP
Occurrence of vapor cavity due to low pressure
Growth of vapor cavity
STOP
http://www.flowtech21.co.kr
- 9 -
3-6. Surge Protection System Types
http://www.flowtech21.co.kr
- 10 - http://www.flowtech21.co.kr
3-7. Features of Water Hammer Protection system Types
ITEM TYPE
Control properties
COMPONENT
FEATURES EXTERNAL POLLUTANT UP SURGE DOWN
SURGE SURGE
CONTROL
Stand Pipe Flowed in Controllable Controllable Passive Pipe
Simple design, needed to install higher than H.G.L. Fluid is exposed to air, which may result in smell leakage in case of sewage water and cause health risk for water supply
Feed Tank Flowed in Uncontrollable Controllable Passive Open Tank
Prevents column separation due to inflow under negative pressure. Installation place is limited as it is fixed on the tip of the pipeline.
Air Valve (Vacuum Breaker)
Flowed in Uncontrollable Controllable Passive Air Valve
(Vacuum Breaker)
Handles negative pressure by letting in air, when negative pressure works in the pipeline. Often installed on the pipeline, making maintenance hard. Pollutants may flow in with air.
Surge Valve Blocked Controllable
Uncontrollable
Passive Control Valve
Control only follows water hammer, and surge control at the time of system failure may be useless.
Air Chamber Blocked Controllable Controllable Active
Pressure vessel Compressor, auto
Control panel
Expensive, positive measure against up/down surge, possible to install in/out doors, and clean by using a closed tank.
- 11 -
4. Structure map of Surge Protection
• Consist of Air-Chamber, Compressor and Control-panel(include a sensor)
http://www.flowtech21.co.kr
5. Key Technology - Summary of patent
`
Real level =sensor detection
LT
50%
Real level value : 50% Level sensor detection: 50%
Off (60%)
On (40%)
On (20%)
Off (80%)
Real level Sensor detection
LT
30%
Real level value: 50% Level sensor detection : 30%
Off (60%)
On (40%)
On (20%)
Pressure tank
Level Transmitter
Level Switch 4ea
Off (80%)
Key Technology # 1 Technology of water level control by using the level switch & level transmitter.
Emergency operate after
find problem by self
Prevent the problem with property damage
and damage of humans by water logging
http://www.flowtech21.co.kr - 12 -
`
5-2. Key Technology - summary of patent
http://www.flowtech21.co.kr
Key Technology #2 Technology of water level control by using the Multiple level transmitter.
Emergency operating after
find a problem by self
Prevent the problem from property damage &
humans by water logging in Mechanical Room
Sensor detection Real level
Real level value : 50% Level sensor detection: 49~52%
LT1
49%
LT2
50%
LT3
52%
Sensor detection Real level
Real level value : 50% Level sensor detection: 49~60%
Pressure tank
Level Transmitter
LT1
49%
LT2
50%
LT3
60%
normal LT3 error (LS1-2=1, LS2-3=32 LS3-1=3 (LS1-2=1, LS2-3=10, LS3-1=11
no problem with 5% mistake! Except the LS3 that common with the LT1, LT2, and control by average values withLS1,2,3) and control by average values with LS1,2)
- 13 -
5-3a. Key Technology - Summary of patent
http://www.flowtech21.co.kr
Key Technology #3 – Power-saving and high reliability in controlling(Air chamber type)
Minimize the
unnecessary
operation of
ventilation
Save the energy &
operation expenses
Relief V/V
Storage Tank
Supply By-pass V/V
Pump
Compressor
Filter
S1 S2
C.V
Discharged Gas Storage Tank
p/s
C.V
s3
PRV 2~10K
2K
Duplex Breaking System
Eco-upper limit (pump stop)
Eco-Lower limit (pump stop)
Duplex Breaking System (lower limit)
Duplex Breaking System (Upper limit)
N.W.L 10kg/㎠.G Normal upper limit(pump operation)
Normal Lower(pump operation)
Traditional water level control method and water level limit
As a new conception of water level control method which is interlocked with pump, it dose not need to rearrange the water level because there is no influence in pipe line when water level is became low after pump stopping. However it can lessens the pressure air & air compressor requirements when the pump is operate as safety device.
Energy-saving through the controlling in connection with the pump
A B C D E Save-energy and skip the dangerous D by operating A~B~E (Three-step) from A~E(Five-step).
10k 6.5k
10k 10k 6.5k
- 14 -
5-3b. Key Technology - Summary of Patent
http://www.flowtech21.co.kr
Key Technology #3 – Enhance Reliability of Surge Protection System & Power-saving Technology
- 15 -
Traditional method :
Take 5~20min Apply the new technology :
Minimize the 20 sec
5~20min
Developed head actual head friction loss radiation pressure
Pump Head pressure
operating
Stopping Developed head
Volume of air/ volume of tank
Pressure air water
Pump operating stopping stopping operating stopping gas
6. Performance Improvement effect
http://www.flowtech21.co.kr
34kW 300sec
none 3kW 20sec
Exist
- 16 -
[saving energy] [Reduce the waiting time]
단위 : kWh 단위 : sec
7. Ripple effect of technical development
1. Energy saving and anti-pollution
◎ Energy saving 91.2%(before 34kWh/19h, after 3.0kWh/19h) ◎ Increase the competitiveness by saving energy
- 17 - http://www.flowtech21.co.kr
2. Ensure safety with high reliability
◎ Keep the target water level, secure a second alternative+ normal operating even the sensor is failure ◎ Reduce the waiting time by safety line from 300sec to 20sec (Improve 93%)
Division Nonperistaltic
time of target water level
Peristaltic time of target water
level
time (s) 300 20
Division Nonperistaltic Peristaltic
19 hour 34 3
0
100
200
300
펌프비연동 펌프연동
300sec
20sec
0
10
20
30
40
펌프비연동 펌프연동
34
3
Nonperistaltic periataltic nonperistaltic peristaltic
Copyright (c) 2013 FLOWTECH Co., Ltd. All Rights Reserved.
Project Q-CHAM II Ethylene Derivatives
Shoaiba II CCPP O2 Resort Multifunctional Administrative City Waterworks
Owner Qatar Chemical Company LTD.
Saudi Electricity Company Taebaek City Deajeon City
Contractor
Daewoo E&C Daelim E&C Kolon Global Co.,Ltd
Location Mesaieed City, Qatar Jeddah, KSA Taebaek, Korea Deajeon, Korea
Spec’
0.5㎥ x 16bar x 2sets 0.6㎥ x 16bar x 14sets
0.6㎥ x 16bar x 4sets 0.3㎥ x 16bar x 3sets
3㎥ x 40bar x 1set 2.5㎥ x 40bar x 1set
80㎥ x 12bar x 1set (40㎥ x 2ea)
Major Reference of Surge Protection System
19
8. References
Copyright (c) 2013 FLOWTECH Co., Ltd. All Rights Reserved.
Project Gumi Filtration Plant
Youngsan River #1-2 Hoiya Filtration Plant Pungnab Waterintake
Owner K-Water KRCC Ulsan City Incheon City
Contractor
Samsung E&C Hyundai E&C
Location Gumi, Korea Muan, Korea Ulsan, Korea Seoul, Korea
Spec’
20㎥ x 16bar x 1set 80㎥ x 16bar x 1set (40㎥ x 2ea)
60㎥ x 16bar x 1set (30㎥ x 2ea)
60㎥ x 10bar x 1set (20㎥ x 3ea)
Major Reference of Surge Protection System
20
8. References
Copyright (c) 2012 FLOWTECH Co., Ltd. All Rights Reserved.
Office. Laboratory ; B-706, Bupyung Lionsvalley #425, Chungchun-Dong Bupyung-Gu Incheon-City, South Korea Tel. 82-32-623-7566 Fax. 82-32-623-6636
LEADING TECHNOLOGY
FLOWTECH CO., LTD.