39 如有改动�, 恕不另行通知.
FLUXUS® 是德国FLEXIM公司商标, 并受其保护.
性能指标
FLUXUS® G80x
特别设计用于危险区, 固定式
特点
• 外夹式, 能精确测量双向及快速变化的气体
• 高低流速下保证高精度测量, 无温度和零点漂移
• 经ATEX, IEC认证, 探头可用于防爆区域
• 经ATEX防爆认证的G800, 其所有电子部件置于防
爆壳体内(IP66), 可通过磁性笔进行操作, 无需打开
外壳
• G801为全不锈钢结构, 耐海水腐蚀, 专为海上(平台)
应用而设计, ATEX防爆认证
• 自动识别探头及其标定数据, 缩短设置时间(小于5
分钟), 并能提供精确, 持久稳定的测量结果
• 久经考验的外夹式探头, 其量程宽, 测量管径范围从
DN7至DN1600, 测量温度范围从-40℃至+200℃;
防尘, 防潮
• 测量不受气体密度, 粘性, 组份, 灰尘, 湿度,温度或
压力的影响
• 友好用户界面
应用
用于各类工业场合, 特别是恶劣的环境下, 尤其是气
体加工和天然气提取, 化工行业, 和石油行业
具体应用有:
• 天然气管道和天然气存储设备测量
• 合成气和注气测量
• 供气行业测量
防爆型, 固定式气体超声波流量计
FLUXUS G800
FLUXUS G801
使用Variofix L安装探头测量
6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2
6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2
40 如有改动, 恕不另行通知.FLUXUS® 是德国FLEXIM公司商标, 并受其保护.
FLUXUS® G80x性能指标
FLUXUS G800G800LG800P
G800LP
G800C24G800LC24
G801G801P
G801C24
款式 防爆型 海上 (平台)型
测量 测量原理 时差相关原理
流速 0.01...35 m/s, 取决于管径尺寸
重复性 0.15% 读数, 视应用而定
- 体积流量 ±1% 读数, 视应用而定±0.5% 读数, 经过标定
介质 被测气体声阻抗与管道声阻抗比>3000,如天然气, 氮气, 空气, 氧气, 氢气, 氩气, 氦气, 乙烯, 丙烷等.
温度补偿 符合ANSL/ASME MFC-5M-1985推荐
主机
电源 100...240V/50...60Hz 或
20...32 V DC 或根据要求: 11...16 V DC
24 V DC ±10 % 100...240V/50...60Hz 或
20...32 V DC或根据要求: 11...16 V DC
24 V DC ±10 %
功耗 < 10 W < 4 W < 10 W < 4 W 通道 1 或2 信号平均 0...100 s, 可调
测量速率(单通道) 100...1000 Hz 响应时间 1 s (单通道), 70 ms 可选
材质 铸铝G800, G800P, G800C24: 粉末涂层
G800L, G800LP, G800LC24: 特殊涂层, 4层
不锈钢 316/316L(1.4401,1.4404,1.4432)
防护等级 (根据EN60529) IP66 尺寸 见尺寸图 重量 6 kg 8.5 kg 固定方式 壁挂式, 2 管固定 (可选) 工作温度 -20...+60 ℃ -20...+50 ℃ 显示 2x16字符, 点阵, 带背光
工作语言 英语, 德语, 法语, 荷兰语, 西班牙语
测量功能
测量量 工况体积流量, 标况体积流量, 质量流量, 流速 累积量 体积, 质量
计算功能 平均值,差值,总和(需2个测量通道)诊断功能 声速, 信号幅度, SNR, SCNR, 时间和幅度的标准差
数据记录
可记录的参数 所有测量量, 累积量及诊断量
容量 >100,000条测量量
通讯
接口 -过程组合: 可选 RS485 (Modbus, emitter)或HART-诊断: RS2321
-诊断: RS2321 -过程组合: 可选 RS485 (Modbus, emitter)或HART-诊断: RS2321
-诊断: RS2321
技术参数
6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2
6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2
41 如有改动�, 恕不另行通知.
FLUXUS® 是德国FLEXIM公司商标, 并受其保护.
FLUXUS G800G800LG800P
G800LP
G800C24G800LC24
G801G801P
G801C24
防爆等级
ATEX
危险区防爆标识
1G800: 0637 II2G Ex de IIC T6Ta -20...+60℃G800L: 0637 II2G Ex de IIB T6Ta -20...+60℃G800P: 0637 II2G Ex de IIC T6Ta -20...+60℃ G800LP: 0637 II2G Ex de IIB T6 Ta-20...+60℃
1G800C24: 0637 II2G Ex de [ib] IIC T4Ta -20...+50℃G800LC24: 0637 II2G Ex de [ib] IIC T4Ta -20...+50℃
1G801: 0637 II2G Ex de IIC T6Ta -20...+50℃G801P: 0637 II2G Ex de IIC T6Ta -20...+50℃
1 0637 II2G Ex de [ib] IIC T4Ta -20...50℃
认证 IBExU01ATEX1064 IBExU01ATEX1064 IBExU05ATEX1078 IBExU05ATEX1078防护型式 电子部分外壳: 隔爆
接线部分外壳: 增安电子部分外壳: 隔爆接线部分外壳: 增安输出回路: 本安
电子部分外壳: 隔爆接线部分外壳: 增安
电子部分外壳: 隔爆接线部分外壳: 增安输出回路: 本安
本安参数 - Um = 250 V本安输出:
Ui = 28.2 VPi = 0.76 WLi, Ci可忽略
- Um = 250 V本安输出:
Ui = 28.2 VPi = 0.76 WLi, Ci可忽略
软件(可选) 软件操作系统(所有WindowsTM版本)
- FluxData: 下载测量值/记录, 图形显示, 格式转换 (例如: ExcelTM) - FluxKoef: 生成被测介质参数
电缆 RS2321 接头 RS232 - USB1 输出(可选)
输出与主设备电隔离 组数 电流输出: 1...2
开关量输出(集电极开路(A)): 1...4
或者电流输出: 1...2开关量输出
(集电极开路)(A)): 1...2开关量输出
(干簧继电器): 0...2或者
频率输出: 1开关量输出
(集电极开路)(B)): 1
电流输出: 1开关量输出
(集电极开路(A)): 1
电流输出: 1...2开关量输出
(集电极开路(A)): 1...4或者
电流输出: 1...2开关量输出
(集电极开路)(A)): 1...2开关量输出
(干簧继电器): 0...2或者
频率输出: 1开关量输出
(集电极开路)(B)): 1
电流输出: 1开关量输出
(集电极开路(A)): 1
电流输出
-范围-精度-有源输出
-无源输出
0/4...20 mA0.1%读数±15μA
G800, G800L:
Rext < 500 ΩG800,
G800LP: Uext = 4...26.4 V,
取决于Rext, Rext < 1 KΩ
0/4...20mA0.1%读数±15μA
-
Uext = 4...28.2 V,取决于Rext, Rext < 1 KΩ
本安
0/4...20mA0.1%读数±15μA
G801:Rext < 500 Ω
G801P: Uext = 4...26.4 V,
取决于Rext, Rext < 1 KΩ
0/4...20mA0.1%读数±15μA
-
Uext = 4...28.2 V,取决于Rext, Rext < 1 KΩ
本安
FLUXUS® G80x 性能指标
6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2 6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2
6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2 6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2
6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2 6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2
6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2 6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2
6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2 6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2
6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2 6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2
6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2 6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2
6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2 6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2
1 仅限危险区范围之外使用
6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2 6 12.1.2009 TSFLUXUS_F7V1-2EN
FLUXUS® ADM 7x07 Technical Specification
Flowmeter
Technical Data FLUXUS ADM 7407 ADM 7407 A2 ADM 7907design standard field device field device for ATEX zone 2 19 " module
measurement measuring principle transit time difference correlation principle,
automatic NoiseTrek selection for measurements with high gaseous or solid contentflow velocity 0.01...25 m/srepeatability 0.15 % of reading ±0.01 m/saccuracy1
with standard calibration ±1.6 % of reading ±0.01 m/swith extended calibration (option) ±1.2 % of reading ±0.01 m/swith field calibration2 ±0.5 % of reading ±0.01 m/smedium all acoustically conductive liquids with < 10 % gaseous or solid content in volume
(transit time difference principle)flowmeter power supply 100...240 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels 1, option: 2signal damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 msmaterial aluminum, powder coated aluminum degree of protectionaccording to EN 60529
IP 65 IP 20
dimensions see dimensional drawing 42TE x 3HE(without back panel)
see dimensional drawing weight 2.8 kg 1.7 kgfixation wall mounting, option: 2 " pipe mounting 19 " rack mounting operating temperature -10...+60 °Cdisplay 2 x 16 characters, dot matrix, backlitmenu language English, German, French, Dutch, Spanishexplosion protection ATEX zone - 2 -marking - II 3G
Ex nA II T4Ta -20...+60 °C
II 3D Ex tD A22 IP66 T100 °C
-
measuring functions physical quantities volume flow, mass flow, flow velocity, heat flow (if temperature inputs are installed)totalizers volume, mass, option: heat quantity calculation functions average, difference, sum data logger loggable values all physical quantities and totalized values capacity > 100 000 measured values1 for transit time difference principle, reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
- volume flow
0.15 % of reading, depending on application
± 1 % of reading, depending on application± 0.5 % of reading, with calibration
2
42 如有改动, 恕不另行通知.FLUXUS® 是德国FLEXIM公司商标, 并受其保护.
301.5259
202
195137
292
2x 3/4 NPT
: 2x 1/2 NPT: 2x M20
2x 1/2 NPT
277
Ø 1
32
189
178
: 4x M25: 4x M20
FLUXUS® G80x性能指标
尺寸 (单位: mm)
FLUXUS G800
FLUXUS G801
HART模式一路电流输出-范围-无源输出
4...20 mAUext = 10...24 V
--
4...20 mAUext = 10...24 V
--
频率输出(可选)(G800P, G801P)
范围集电极开路
0...5 kHz30 V/100 mA可选: 8.2 V
DIN EN 60947-5-6(NAMUR)
--
0...5 kHz30 V/100 mA可选: 8.2 V
DIN EN 60947-5-6(NAMUR)
--
开关量输出
干簧继电器集电极开路(A)
集电极开路(B)
48 V/0.25 A24 V/4 mA
G800P:30 V/100 mA
-24 V/ 4 mA可选
--
48 V/0.25 A24 V/4 mA
G801P:30 V/100 mA
-24 V/ 4 mA可选
--
作为报警输出 -功能 上下限, 符号变化或出错 上下限, 符号变化或出错 上下限, 符号变化或出错 上下限, 符号变化或出错
作为脉冲输出 -脉冲值 -脉冲宽度
0.01...1000 units1...1000 ms
0.01...1000 units 1...1000 ms
0.01...1000 units1...1000 ms
0.01...1000 units1...1000 ms
43 如有改动�, 恕不另行通知.
FLUXUS® 是德国FLEXIM公司商标, 并受其保护.
壁挂式和2 管固定
FLUXUS® G80x 性能指标
10 12.1.2009 TSFLUXUS_F8V1-2EN
FLUXUS® ADM 8x27 Technical Specification
Wall and 2 " Pipe Mounting Kit FLUXUS ADM 8027
FLUXUS ADM 8127
6
FLUXUS G800
FLUXUS G801
如有改动, 恕不另行通知.FLUXUS® 是德国FLEXIM公司商标, 并受其保护. 60
材质: 不锈钢 304 (1.4301),
301 (1.4310)材质(可选):不锈钢 316 (1. 4571),
316L(1.4404), 17-7PH (1.4568)
导轨长度: 尺寸:
VLK: 423 x 90 x 93 mmIP68 (可选) : 443 x 94 x 105 mmVLM: 309 x 57 x 63 mm VLQ: 247 x 43 x 47 mm
探头固定夹具选择(适用于固定式流量计)
Variofix L (VL) (支持G、H、K、M、P、Q探头)
VLK: 348mm (对应G、H、K探头)IP68 (可选): 368mmVLM: 234mm (对应M、P探头)VLQ: 176mm
(对应G、H、K探头)
(对应M、P探头)
探头固定夹具选择
如有改动�, 恕不另行通知.FLUXUS® 是德国FLEXIM公司商标, 并受其保护. 61
探头固定夹具选择 性能指标
Variofix C (VC) (支持G、H、K、M、P、Q探头)
材质: 不锈钢 304 (1.4301),
301 (1.4310)材质(可选):不锈钢 316 (1.4571)
导轨长度:
VCK-xL: 500 mmVCK-xS: 350 mmVCM: 400 mmVCQ: 250 mm
尺寸:
VCK-xL: 560 x 122 x 102 mm,IP68 (可选): 560 x 126 x 120 mmVCK-xS: 410 x 122 x 102 mm,IP68 (可选): 410 x 126 x 120 mmVCM: 460 x 96 x 80 mmVCQ: 310 x 85 x 62 mm
探头固定夹具选择(适用于固定式流量计)
(对应G、H、K探头) (对应G、H、K探头)
(对应G、H、K探头)(对应G、H、K探头)
(对应M、P探头)
(对应M、P探头)
如有改动, 恕不另行通知.FLUXUS® 是德国FLEXIM公司商标, 并受其保护. 62
Variofix VP G、H、K、M、P、Q
301 (1.4310)303 (1.4305)
414×94×76mm364 m 304 (1.4301) , ,
探头固定夹具选择性能指标
如有改动�, 恕不另行通知.FLUXUS® 是德国FLEXIM公司商标, 并受其保护. 63
探头固定夹具选择 性能指标
探头固定夹具选择(适用于便携式流量计)
303 (1.4305)
滑尺长度: FSM:320mmFSQ:320mmFSS:120mm
材质: 不锈钢 304 (1.4301) ,
301 (1.4310) ,
Fastening Shoes (FS)(支持M、Q、S探头)
FSQ,FSM夹具 FSS夹具
尺寸:FSM: 420×48×68mmFSQ: 420×48×68mmFSS: 210×32×44mm
如有改动, 恕不另行通知.FLUXUS® 是德国FLEXIM公司商标, 并受其保护. 64
探头固定夹具选择性能指标
303 (1.4305)
420 x 55 x 68 mm FSM: 320mm FSQ: 320mm
304 (1.4301) , 301 (1.4310) ,
( ) ( M Q )( Fastening Shoes )
如有改动�, 恕不另行通知.FLUXUS® 是德国FLEXIM公司商标, 并受其保护. 65
探头固定夹具选择
尺寸: 180 × 103 × 40mm
挠性管夹具(支持Q、S探头)
材质:不锈钢 304(1.4301) 301(1.4310) 303(1.4305)
导轨长度:42mm
探头固定夹具选择 性能指标
如有改动, 恕不另行通知.FLUXUS® 是德国FLEXIM公司商标, 并受其保护. 66
连接组合(NL、AS、TS)
连接组合 AS (非防爆探头)
探头类型(探头订货编号的第3个字母)
G, H, K M, P Q S
x y l x y l x y l x y l
电缆长度
电缆长度(LC可选)
≤100 2 2 ≤100 2 1 ≤50 1 1 20m
FLU
XU
S主机
xl y
2 3
≤100 - - - - - - - - -m 2 7
连接组合 NL(非防爆探头)
探头类型(探头订货编号的第3个字母)
G, H, K M, P Q S
x y l x y l x y l x y l电缆长度
电缆长度(LC可选)
≤ 10mm
FLU
XU
S主
机
2 3
x, y - 探头电缆线长度 l - 延长电缆最大长度
≤ 1011≤ 1012≤ 1022≤ 102 7 ---≤ 1018≤ 1027
l x y
连接组合
如有改动�, 恕不另行通知.FLUXUS® 是德国FLEXIM公司商标, 并受其保护. 67
连接组合 性能指标
x, y - 探头电缆线长度 l - 延长电缆最大长度
连接组合 TS
通过接线盒和延长电缆连接
直接连接
G, H, K M, P Q S
mmm
(
(仅适用于ADM 7407、ADM 7407A2、G704、G704A2)
ADM 7407, ADM 7407 A2)
ATEX zone 2, FM, 不防爆
FLU
XU
S主
机
ATEX zone 1 , ATEX zone 2 (含IP68 探头), 不防爆 (含 IP68 探头)
FLU
XU
S主机
探头类型(探头订货编号的第3个字母)
电缆长度
电缆长度(LC可选) 电缆长度(IP68可选)
59
12
x≤300≤300≤300
I4-
12
x≤300
≤300-
I3x
≤90I
≤2x
≤40I
连接组合
ATEX zone 1
FLU
XU
S主
机
延长电缆
延长电缆
JB01
--
--
--
--
x
l
FLU
XU
S主
机
x
x
l
JB02, JB03
FLU
XU
S主
机 x
x
l
JB01, JBP2, JBP3
FLU
XU
S主机
x
延长电缆
如有改动, 恕不另行通知.FLUXUS® 是德国FLEXIM公司商标, 并受其保护. 68
mm
(
JB01 JB02 JB03 JBP2 JBP3
2 ( ) 2 ( ) 2 ( ) 2 ( ) 2 ( )
316L (1.4404)
304 (1.4301)
OS: 316L (1.4404)
304 (1.4301)
OS: 316L (1.4404)
IEC/EN 60529)IP67 IP67 IP67 IP67 IP67
°C -40 -40 -40 -40 -40°C +80 +80 +80 +80 +80
ATEX/IECEx
1 2 - 2 -
ATEX IECEx
Ex e mb II (T6)...T4Ta -40...+(70)80 °CEx tD A21 IP67 T 100 °C
II3G Ex nA II (T6)...T4Ta -40...+(70)80 °CII3D Ex tD A22 IP67 T 100 °C
-II3G Ex nA II (T6)...T4Ta -40...+(70)80 °CII3D Ex tD A22 IP67 T 100 °C
-
IBExU06ATEX1161 - - - -IECEx IBE 08.0006 - - - -
:••
:
- -
316L (1.4404)
316L (1.4404)
II2GII2D0637
174
119270
163.5
156
Ø 9
: 3x M20 x 1.5: 2x M20
: :
接线盒
如有改动�, 恕不另行通知.FLUXUS® 是德国FLEXIM公司商标, 并受其保护. 69
电缆选择
技术参数
延长电缆探头电缆
订货编号 连接组合 ASAS,TS TS AS,TS TS标准长度
10-
最大长度 °C -55...+200 -40...+100 -100...+225 -25...+80 -40...+70
长久防水性能 不含卤 火焰传播测试 根据 IEC 60332-1
燃烧测试 根据 IEC 60754-2
外套
(1.4301)可选: 316L (1.4404)
- -
8 - 8 - -电缆外壳
PTFE PUR PFA TPE-O PUR 2.9 5.2 ±0.2 2.7 8 12
25.09.03.0厚度
黑白灰棕颜色
xxxxx屏蔽
m 1
m
mm
mmmm
见连接组合表 12 见连接组合表
- - - 见连接组合表 见连接组合表
温度
- 不锈钢 304 (1.4301)可选: 316L (1.4404)
材质
外径
黑
材质 不锈钢 304
外径
1699 2550 6111 2551 2615
电缆选择
如有改动, 恕不另行通知.FLUXUS® 是德国FLEXIM公司商标, 并受其保护. 70
温度探头
温度探头 (可选)
技术参数
订货编号
类型
670415-1PT12N PT12N PT12N PT12N PT12F PT12F
770415-1670414-1770414-1
770415-1A2 770414-1A2 670415-2 670414-2
等同Pt100根据DIN 1434-1
等同Pt100根据DIN 1434-1
等同Pt100根据DIN 1434-1
001tP种类
连接
Pt100ATEX zone 2
Pt100
4线
设计 快速响应
052+...05-052+...03-052+...03-C°测量范围
2 + C° 51.0(±T精度
精度
× 10-3 . T [°C]), class A class A class A
±(0.15 °C + 2 10-3 . T [°C]), ±(0.15 °C + 2 10-3 . T [°C]),
-△T ≤ 0.1 K(3K < △T < 6 K),
EN 1434-1
- ≤ 0.1 K(3K < T < 6 K),
EN 1434-1
- ≤ 0.1 K(3K < �T < 6 K),
EN 1434-180505s响应时间
403 ,KEEP外壳(1.4301), Cu
防护等级(根据EN60529)
66 PI66 PI66 PI
重量(不包含接头) 0.25 0.5 0.25 0.5 0.32 0.64固定方式
--配件尺寸
415151长 l035151b宽
720202高 h尺寸图 670415-1: A
770415-1: C670414-1: A770414-1: C
BC
防爆等级
防爆温度ATEX
-2-危险区
-03--最低温度-052+-最高温度
-防爆标识 II3GEx nA II T6...T2 GcTa -30...+250 °C
-
kg
mmmmmm
4线 4线
△ △
对应 对应 对应
铝 铝 不锈钢
外夹,钢带 外夹,钢带 外夹,珠链
塑胶保护板,隔热层
℃
℃
× ×
如有改动�, 恕不另行通知.FLUXUS® 是德国FLEXIM公司商标, 并受其保护. 71
温度探头 性能指标
温度探头
连接
接头
pin 温度探头电缆 延长电缆
1 2
5 ,4 ,36
78
mm 52.0 x 4 2 LIYCY 8 x 0.14 mm2
52/01/53002-CVPEFTP
h
l
C
B
h
l
A
C
mm
延长电缆
延长电缆
接线盒
红/蓝 红 白/蓝 白
红/蓝
白/蓝 蓝灰
不连接
红
白
红
白不连接
电缆
温度探头电缆 延长电缆
种类
标准长度
最大长度
电缆外套
黑或白 灰
如有改动�, 恕不另行通知.FLUXUS® 是德国FLEXIM公司商标, 并受其保护. 57
液体探头选择
探头选择
类型(5系列)
50M5L7 100 2500
10Q5L7 25 150
5 10 50 100 500 1000 5000管道内径[mm]
推荐范围 可达范围
类型(除5系列外)
100FSK 200 3600 6500
50FSM 100 2000 3400
25FSP 50 200 600
10FSQ 25 150 400
FSS 6 10 70
5 10 50 100 500 1000 5000
推荐范围 可达范围 管道内径[mm]
探头选择
如有改动, 恕不另行通知.FLUXUS® 是德国FLEXIM公司商标, 并受其保护. 58
探头选择性能指标
气体探头选择
选择兰姆波探头:
类型
1.壁厚选择
GLG 11 23
GLH 7 15
GLK 4 9
GLM 2 5
GLP 1...3
GLQ 0.5...1
5 10 15 20 25管道壁厚[mm]
70
类型
GLG
GLH
GLK
GLM
GLP
GLQ
30 80 190 600 1500
190 220 900 1600
120 140 600 1000
60 80 300 500
30 40 90 150
15 20 50
7 10 22 35
推荐范围 可达范围
管道内径[mm]
2.管径选择