Upload
others
View
7
Download
0
Embed Size (px)
Citation preview
Flow, Velocity, Level, Water Quality, RainfallReal-time Monitoring, Remote Control, Cloud Management, Mobile Operation, Anytime and Anywhere ■ Non-Contact Innovative Radar Measurement Technology■ Real-time Data and Alarm Communication■ Non-Contact Innovative Radar Measurement Technology ■ Ultra Low Power Consumption, up to 10 Years of Operation on Internal Battery■ Robust IP68 Enclosure, Continuous Submersible to 10 m of Water, Solution without Cabinet ■ -40~85°C Operating Temperature, 0~100% RH Operating Humidity■ Support Cellular Communication, No Field Data Collection ■ Auto Delivery Incomplete Uploads to Ensure No Data Loss■ Simultaneous Acquisition of 8 Smart Digital Sensors and I/O Modules, 1 barometer Sensor and 2DI, 2AI Signals ■ Built-in Standard Modbus TCP Communication Protocol ■ Integral FTP Protocal, Directly Upload Log Files to User Server■ Standard OPC Server Software to Seamlessly Connect SCADA Software and Database■ Cloud Based Platform for Configuration, Operation, Monitoring, Alarm, Control and Data Analysis
RoHS
OutstandingAward
+75°C-25°C
WIDETEMPERATURE
ULTRA LOWPOWER
GOOGLEEARTH
100%
UVRESISTANT
SECURITYLOCK
SOLARPOWER
LOG
SURGEPRESSURE
WIRELESSNETWORK
IFTHENELSE
CONTROLRULES
MULTIPLEI/O
MULTIPLESENSORS
AlarmProfile
SMSMESSAGE
DATAQA/QC
144.9144.9 145
8.118.118.11
STATISTICS ANALYSIS
DATALOG
OPCSERVER
BATTERYOPERATION
ALARM GPS POSITION
GPRSNETWORK
GPRS
IP68PROTECT
FLO Series
Sewer Systems Stormwater Runoff Municipal and IndustrialWastewater
Rivers and Streams Irrigation Channels
© 2018 AQUAS. All rights reserved. Specification and product information contained herein are subject to change without notice.Performance varies depending on hardware, software and overall system configuration.Warrenty and RMA policy varies with countries, please check with your local distributors or visit www.aquas.com.tw/en
Battery & Solar Powered, Cellular CommunicationFLO Open Channel Flow Monitoring System
Water Instruments, Wireless Controller & Logger, Monitoring Bouy, Multiparameter Water Quality Sonde, Water Quality Spectrometer, Handheld Meter, Cloud-Based SCADA Software
Sensors, I/O Modules, Data Acquistion, log, Communication, Display, Alarm, Control, Cloud Storage, Big Data Analysis, Artificial IntelligenceCreating the Future of Our Water
FLO Series
■ Borderless deployment without standard cabin, signal transmitter, communication module, power supply,surge isolation and lighting arrester■ Eliminate power/networking/sensor/IO cabling, software configuration, engineering and infrastructure cost
■ Seamless connection to public or private network and software solutions■ Easy to install, no need for calibration and quick connect within seconds. It is Ideal for mobile operation■ Low maintenance and trouble shooting. Minimizes running and operating cost
■ Sewer Systems■ Stormwater Runoff■ Municipal and ndustrial Wastewater■ River and Streams■ Irrigation Channels
1
The FLO series is a highly reliable and cost-effective open channel flow meter with innovative technology for flow monitoring, communication, logging, alarming, control and analysis applications.
It is built-in with flow modules, I/Os, cellular communication, Bluetooth, RS485 and GPS module.
With robust IP68 water submersible enclosure, the product is designed for frequently flooded underground chambers and extreme temperature and humidity, outdoor locations such as sewer systems, river, channels etc.
Ultra low power consumption allows battery or solar power tp ensure for 5 years of continuous operation.
The RS485 port is able to connect up to 8 SMR water quality analyzers including free chlorine, pH, ORP,temperature, conductivity, resistivity, dissolved oxygen, turbidity, salinity, suspended solid, ammonium, nitrate and COD ...etc.
Benifits
Application
Primary Devices>2Hmax
4
1H
>2Hmax
L >2Hmax
H
>2Hmax
L
H>2H
L >2HmaxA
H
>2Hmax
H
w
θ
H D6
D2
D
H
30 30
D4
D4
1.1D
1.9D
1
2 D
H
2.2D
1
1 S
H
1.05D
.383D
1
6 D
H
D
H
> 6d
H
D
D
H w
H
CIPOLLETTI Weir Rectangular Weir (Contracted) V-Notch Weir Rectangular Weir (Non-Contracted)
Parshall Flume Trapezoidal Flume Palmer Bowlus Flume H-Type Flume HL-Type Flume HS-Type Flume Leopold Lagco Flume
California Pipe (Nozzle) Manning:Circular Pipe Manning:Rectangular Channel
W
Hr= W
2
Manning:U-Shape Channel
w
T
H
Manning : Trapezoidal Channel
Upstream Level
Downtream Level
Submerged Rectangular Orifice
H1H2
L
h
Upstream Level
Downtream Level
Imperfect Contraction Rectangular Orifice
H1H2L
h
River and Stream
Creating the Future of Our Water
►Completely Self Contained■ 4G/GPRS five band 800/850/1700/1900/2100 MHz cellular communication■ Integral long life Lithium battery to sustain 10 years continuous operation ■ Optimized solar power module, solar panel and rechargeable Lithium battery for 3 years continuous operation
►Robust Outdoor Construction ■ IP68 housing, continuous submersible to 10 meters of water ■ Operating temperature: -40 to 85 °C; operating humidity: 0~100% RH ■ Anti-corrosive SS316 or Titanium connector■ 1500N tensile strength Kelvar reinforced cable
►High Capacity and Flexibility■ Multiple flow modules: hydrostatic level, radar level, radar velocity and level■ Multiple communication selections: cellular, R485■ I/O modules: 2 digital inputs, 2 analog inputs■ Externl I/O modules: Connect up to 16 digital/analog inputs ■ Power supply: external power, inernal battery, solar power and external battery box ■ RS485 port: up to 8 SMR digital analyzers, transmitters, I/O modules and 1 Modbus instrument ■ 2,000,000 log data storage capacity, including flow rate, flow volume, velocity, level, water quality...etc■ Superior communication performance in sewer systems and outdoor enviroment
►Easy Setup ■ Bluetooth cable-free operation and configuration■ Cellular/WiFi over the air cloud configuration, log data download and firmware update■ Setup operation parameters, monitor system, I/O, Sensors, battery voltage and capacity, cellular/GPS signal and calibrate sensor via AQCFG configuration software■ 2.4” LCD display of flow, velocity, level, water quality , I/O Status, battery capacity■ Cloud firmware upgrade via cellular communication
►Smart Function■ Scheduled and alarm communication: data collection, SMS, alarm notification, data upload, setting download, store and forward; accelerate upload frequency while alarming■ Log: periodical, event, alarm■ Configurable alarm (HH, H, L, LL) and actions including, SMS, alarm log and control outputs
■ Arithmetic functions (+, -, x, ÷) for registers to setup the alarm conditions■ Peer to peer communication for I/O and data exchange■ Forecast of battery operation days and early warning of low battery to avoid unpredicted breakdown
►Auto Data Collection, Cloud Storage, WEB Operation and Monitoring■ Standard Modbus TCP protocol■ Central communication application programming library for field data collection and database integration■ Directly upload CSV format log files to user FTP servers■ Web configuration ,operation, monitoring, alarm, control, Google Map display, statistical analysis, transient pressure analysis, trend, bar graph and tabular report functions ■ Automatic registration and synchronization of device ID, serial number, alias, location and operation settings ■ GPS and time logged together with I/O and sensor values■ SQL and mySQL database connection for development of application software■ Seamless SCADA software and database connectivity via OPC server■ Anytime and anywhere internet operation and monitoring■ Simultaneously upload data to 2 servers to build up dual database and operation centers ►Security■ Login password access protection■ 128 bits cellular AES encryption to prevent unauthorized access■ GPS location deviation anti-theft alarm■ Secure cellular communication via virtual private network (VPN)
2
FLO SeriesFeatures
Creating the Future of Our Water
3
FLO Series
IP68 enclosure
16MB solid state,rotating memory, no data loss after power failure
Operating temperature: -40~85 °COperating humidity: 0~100% RH
2.4” LCD display
High gain anti theft, anti sabotage antenna
● Port2: I/O Module
● 4-20 mA*2● Pulse/Status Inputs*2
Cellular GPS
Bluetooth
● Port0: System Configuration
►RS485 ● Connect notebook with AQCFG software for System configuration and data upload/ download ● PLC/DCS/HMI Communication
►Select various flow modules for different applications
RadarLevel
Radar Flow Velocity and Level
SMR61Hydrostatic
Level
SMR02 SMR65
►External Power :
9~18 V DC ±10%, 1.5 A
►External Battery:
● Power
BAT11-2 3.6 V DC 180 AH IP68 Rechargeable Battery Pack
►Internal Batery:
BAT02: 3.6 V DC 10 AH Rechargeable Battery
►Internal Battery:
BAT01-1 3.6V DC 28 AH Non-rechargeable Battery
● Port1: RS485 Sensors
► Connect up to 8 SMR smart digital sensors, includes flow modules and water quality analyzers● SMR flow modules: submerged pressure, radar level, radar velocity and level ● SMR water quality analyzers (or MAX multiparameter sonde): pH, ORP, temperature, conductivity (salinity), dissolved oxygen, turbidity, Nitrate (NO3-N), Ammonium (NH4-N), COD● SMR weather sensors: rainfall, wind speed and direction, humidity and temperature
Radar Flow Velocity and Level- The Radar sensor remotely measures surface flow velocity and level in open channel and river with advanced Radar Doppler velociety and level technology.- Multiplying the converted average velociety by the wetted area yields the flow rate.
Radar Flow Velocity
Radar Level- The Radar sensor measure the elapased time between sending and receiving reflection from the water surface to determines the level in the channel- Closely measure the rate of flow in an open channel of uniform cross section, cosistent slope, roughness and flow moves by gravity force only- Level to flow rate for weirs (V-notch, Trapezoidal, Suppressed Rectangular, Contracted Rectangular and flumes (Parshall, Palmer Bowlus , Leopold Largo Khafagi Venturi)- Level vs. Flow custom programmable curve (up to 32 points)
Radar Level
D H
Submerged Pressure- Use a pressure transducer to measure the depth of the liguid. The barometer or air pressure sensor automatically compensates for changes in atomospheric pressure to maintain accuracy- Closely measure the rate of flow in an open channel of uniform cross section, cosistent slope, roughness and flow moves by gravity force only- Level to flow rate for weirs (V-notch, Trapezoidal, Suppressed Rectangular, Contracted Rectangular and flumes (Parshall, Palmer Bowlus , Leopold Largo Khafagi Venturi)- Level vs. Flow custom programmable curve (up to 32 points)
Submerged Pressure
Block Diagram
FLO Flow, Level ,Water Quality, Rainfall Monitoring and Control System: RS485 Port + I/O Module (2DI, 2AI)
Creating the Future of Our Water
FLO Series
4
AQWEB/AQOPC Station■ Notebook with AQCFG software for configuration■ AQWEB WEB Server software for configuration, automatic data acquisition and storage, remote monitoring, alarming, control, Google Earth fusion display, data analysis, transient pressure analysis, time series trend graph and tabular report functions■ Seamless SCADA software and database connectivity via AQOPC OPC server ■ Application interface library for developing user customized software
FLO Multiparameter Open Channel Flow Monitoring System■ Periodically sample digital transmitters, I/Os and serial devices, logged with time stamp ■ Borderless cellular and WiFi communication■ Peer to peer communication
SMR Sensors and I/O Module ■ RS485 serial communication■ Standard Modbus RTU protocol■ Up to 1.2 Km transmission distance
The FLO Series is fully integrated with cellular, Bluetooth, RS485 and Ethernet communication, providing seamless connections from sensors and I/O to public or private network.
System Architecture
Smart Water Cloud● Management Server● Web Server● Alarm Server● Communication Server
● Storage Server● Application Server● Display Server● Computation Server
iPhone
BlackBerry
Android
Safari
IE
Registration
Configuration
Alarm
Control
Data&ImageUpload/Download
Support● Auto Registration● Account Management● Region Management● Remote Diagnosis
Operation● Remote Configuration● Monitoring● Alarm● Control● Trend● Graph● Statistics Report
Maintainance● Firmware Update● Auto Synchronization● Battery Status● Communication Quality● Sensor Calibration and Diagnosis iPad
N
W
S
E
NW
SW
SE
NE
SMRSmart Sensors and I/O Modules
FLOCellular
Multiparameter Open Channel Flow Monitoring System
Monitoring & Operation
Alarm
Trend
Data Analysis
Flow Chart
F
ree C
hlorin
e, ORP, Temperature
pH
, Sali
nit
y, Suspended Solid
Turb
idity,
Ammonium, TDS
Con
ducti
vit
y, Dissolved Oxygen,
Pressure
Leaka
ge
CH4, H2S
CO, O2
Transient Pressure Flow
Noi
se
Rainfal
l, Hum
idity
,
Wind
Spe
ed,
W
ind D
irect
ion,
Solar R
adia
tion,
Bar
omet
er,
Level Valve
Position Im
age
Differential Pressure
Multiple Parameters Applications
Velocity
Creating the Future of Our Water
FLO Series
5
►Main UnitGeneral■ CPU: 32 bits, 72MHz■ Dynamic Memory; type: SRAM; Size: 128KB■ Solid state memory: type: non-volatile flash; Size: 16 MB; rotating, no log or setting data loss after power failure■ Real-time Clock: crystal controlled calendar clock with leap year adjustment; accuracy: 5 seconds per month; GPS and NTP server auto time synchronization,accuracy: 1 ms (GPS), 1~3 sec (NTP) ■ Environment: protection: IP68, continuous submersible to 10 meters of water; operating temperature: -40~85 °C; operating humidity: 0~100% RH■ Safety: CE, FCCPort 0: RS485■ System configuration, diagnosis and data pload/download■ 115,200 bps, 8 data bits, no parity, 1 stop bit■ Surge protection: 4000 V DC■ Protocol: Modbus RTU or proprietary device drivers LCD Display ■ 2.4” with back light■ Display: sensor and transmitter values, I/O status, battery and communication status, unit ■ 3 numbers: 9 digits,4½ digits,1½ digits ■ Dimensions: 60(W) x 34(H) Housing■ Material: engineering ABS plastics with polycarbonate■ Dimensions: φ110 x 130 mm ■ Weight: approx. 900 g ►Function■ Data Collection: flow, velocity, level, water quality, SMR analyzers and transmitters, Modbus RTU devices■ Communication: data transmission; SMS alarm notification; data upload/download (always on~24 hours); store and forward; FTP■ Log: 2,000,000 data values, rotating store; periodical (1 sec~24 hours), event, alarm, transient pressure■ Alarm: HH, H, L, LL 4 level thresholds; alarm log►PowerExternal Power■ Voltage: 9-18 V DC ±10%, 1.5 A■ Surge protection: 4000 V DC■ Isolation: 1000 V DC■ ESD line rotection:15 KV DCInternal Battery (BAT01-1)■ Non-rechargeable 3.6 V DC 28 AH lithium cell■ Life: 10 yearsInternal Battery (BAT02)■ Rechargeable 3.6 V DC 10 AH lithium cell■ Life: minimum 300 charge/discharge cyclesExternal Battery (BAT11-2)■ IP68 rechargeable 3.6 V DC 180 AH lithium battery pack■ Life:minimum 300 times charge/discharge cycles■ Dimension: 200(W)x200(H)x130(D)mm■ Weight: approx. 5.7 Kg►CommunicationGPRS Module■ Standard: GSM/GPRS■ Frquency: 850/900/1800/1900 MHz■ Antenna: 3 dBi■ SIM Card: normal (15x25 mm)■ Protocol: Proprietary or Modbus TCP4G Module■ Standard: LTE■ Frequency: 800/850/900/1800/2100/2600 MHz ■ Antenna: 1 dBi (internal; 2 dBi(external)■ SIM Card: Micro SIM (12x15 mm)■ Protocol: Proprietary or Modbus TCPNBIoT Module■ Standard: LTE■ Frequency: 700/800/850/900 MHz■ Antenna: 1 dBi (internal; 2 dBi(external)■ SIM Card: Micro SIM (12x15 mm)■ Protocol: Proprietary or Modbus TCP►Flow ModulePort 1: RS485 Port ■ Device data collection, connecting up to 8 SMR digital sensors (includes 1 flow module) ■ 19,200bps, 8 bits, no parity, 1 stop bit■ Surge protection: 4000 V DC ■ Protocol: Modbus RTU● Hydrostatic Level■ Principle: differential pressure transducer to measure the depth of the liquid .The logger built-in barometer or pressure automatically compensates for changes in atmospheric pressure to maintain accuracy■ Measurement parameters : level, flow rate, flow volume■ Primary Devices: Bulit-in calculation formula of parshall flume, Palmer Bowlus flume, V-notch weir, Round pipe, rectangular and trapezoidal channels and level vs. flow custom programmable curve (up to 32 points). It provides accurate measurement at sites where winds, steam, foam, turbulence, or air temperature fluctuations exit. The probe can accurately sense pressure even when covered with silt and sand.■ Measurement range: level: 0~10 m; flow rate: 0~100 cmh; flow volume: 0~1,000,000,000 m3■ Accuracy: level: ±0.1% FS■ Resolution: level: 0.01% FS; flow rate: 0.01 cmh; flow volume: 0.01 m3
● Radar Level Module ■ Principle: Mounted above the stream, uses radar doppler technology to remotely measure level. The wetted area is calculated from the level and multipling with the converted average velocity to calculaate the flow ■ Measurement parameters : level, flow rate, flow volume,■ Primary Devices: best suited where weirs and flumes are not practical, and where submerged, full-pipe, surcharged, and reverse flow conditions may occur.,■ Measurement range: level: 0.1~20 m; flow rate: 0~100 cmh; flow volume: 0~1,000,000,000 m3■ Accuracy: level: ±2 mm■ Resolution: level: 1 mm; flow rate: 0.01cmh; flow volume: 0.01m3● Radar Velocity and level Module ■ Principle: Mounted above the stream, uses radar doppler technology to remotely measure surface velocity, while simultaneously measuring level. The wetted area is calculated from the level and multipling with the converted average velocity to calculaate the flow ■ Measurement parameters : velocity, level, flow rate, flow volume,■ Primary Devices: best suited where weirs and flumes are not practical, and where submerged, full-pipe, surcharged, and reverse flow conditions may occur.,■ Measurement range: flow velocity: 0.1~15 m/s; level: 0.1~20 m; flow rate: 0~100 cmh; flow volume: 0~1,000,000,000 m3■ Accuracy: flow velocity: :±0.01 m/s or ±1% FS; level: ±2 mm■ Resolution: flow velocity: 0.1 mm/s; level: 1 mm; flow rate: 0.01cmh; flow volume: 0.01m3Port 2: I/O Module● I/O Module 1 (2DI, 2AI)Digital inputs■ Number of channels: 2 counter or state inputs ■ Type: 3.0-12 V DC or dry contact single ended input■ Maximum operating frequency: 100 Hz■ Minimum pulse width: 2 msec ■ Surge protection: 4000 V DC
Analog inputs ■ Number of channels: 2■ Resolution: 15 bits; ■ Accuracy: 0.025% FS ■ Signals: 4~ 20 mA; 0~10 V DC (optional) ; 0~ 1 V DC (optional); 0~ -2.5 V DC(optional) ■ Surge protection: 4000 V DC
►OptionalsBarometer module■ Measurement range (gauge pressure): 0~2 Kgf/cm2■ Accuracy: ± 0.1% FS■ Resolution: 0.01% FS■ Repeatability: ±0.025% FS■ Stability (annual): ±0.1 % FS■ Housing: SS316L; Titanium (optional)
GPS Module■ Frequency: 1575.42 MHz■ Position accuracy: 2.5 m ■ Time accuracy: 300 nsec ■ Antenna: 28±3 dBi
Solar Panel■ Type: multi-crystalline silicon solar cell■ Efficiency: 17% (1000 W/m2, 25 °C )■ Max Power (Pmax): 3 Watts (PAN02, PAN05); 8 Watts (PAN03)■ Optimal operating voltage (Vop): Max. 6 V DC ±10%■ Optimal operating current (Iop): Max. 400 mA ±10% (PAN01, PAN05); 1A ±10% (PAN03)■ Open circuit voltage (Voc): 6.5 VDC ±10%■ Short circuit current (Iss): 500mA ±10%■ Operating temperature: -30 ~ 70 °C ■ Protection: IP67 ■ Housing: Back - aluminum ; Front - reinforced glass■ Dimension: PAN02- 170(W)x155(H)x10(D)mm PAN03- 290(W)x250(H)x35(D)mm PAN05- Φ 200x75(H)mm* PAN05 IP68 road mount solar panel sustains up to 15 ton weight loading
Bluetooth Module ■ System configuration, diagnosis and data upload/ download■ Standard Bluetooth 4.0■ Data rate up to 3 Mbps■ Frequency: 2.412~2.497 GHz ■ Range: up to 50m■ Antenna: 1dBi
Specifications
Creating the Future of Our Water
FLO Series
Ordering Codes: FLO
Main Unit and Flow ModuleHydrostatic LevelRadar LevelRadar Flow Velocity and Level
CommunicationRS485GPRS4GNBIot
PowerExternal PowerInternal Battery (Non-rechargeable, 28AH)Internal Battery (Rechargeable,10AH)External Battery (Rechargeable, 180AH)
AntennaNoneBuilt-inExternal
Optionals:• GPS Module • Bluetooth Module• Barometer Module
123
0178
0123
012
Cable (22 AWG, 5 wires, shielding, Kelvar reinforced material, 1500N tensile strength)
CAB0 3TypeNon-Vented
Length(m)
MaterialPUR
001~999
Ordering
7E-mail: [email protected] ● Phone: +886-2-8797-5358 ● Fax: +886-2-2657-8926Address: AQUAS INC. 4F.-2, No.56, Ln. 321, Yangguang St., Neihu Dist., Taipei City 114, Taiwan
SMR I/O Modules
Accessories
Dimensions
Order No. DescriptionCAB02 Configuration cable (1.5 m, USB interface)CAB12 IP68 2 port RS485 cable (20 cm)ANT03 IP68 cellular/WiFi antenna (1-3dBi, 5m cable)ANT04-1 IP68 road mount cellular/WiFi antenna (1-3dBi, 5m cable)MSW01 LCD switch
Order No. DescriptionSMR13 Humidity and temperature transmitterSMR15 BarometerSMR24 AnemometerSMR29 Rainfall gaugeSMR30 Solar radiation transmitterSMR54 Soil moisture meterSMR22 Network cameraSMR20 Gate position transmitter
Order No. DescriptionBAT01-1 3.6 VDC 28 AH, non-rechargeable lithium batteryBAT02-1 3.6 VDC 10 AH, rechargeable lithium batteryBAT11-2 3.6 VDC 180 AH, IP68 rechargeable lithium battery boxPAN01 IP67 6 VDC, 3 W solar panelPAN05 IP68 6 VDC, 3 W road mount solar panel
Battery and Solar Panel
BAT11BAT01 BAT02 PAN01 PAN05
Hub Cable and Antenna
SMR Weather Sensors and Camera
BOX01 BOX02 CAB06 CAB12 ANT03 ANT04-1 MSW01
Order No. DescriptionSMR16-1 Analog input module (2 channels)SMR17-4 Digital input module (8 channels)SMR18-1 Digital output module (8 channels)SMR19-1 Analog output module (2 channels)
Battery Operation Time
Battery Power Log Data Upload Battery Life
3.6 VDC, 28-AH (INR) 1 minute4 hours 5 + Years
30 minutes 1 + Year
3.6 VDC, 10-AH (IR) 1 minute24 hours 2 + Years2 hours 1 + Year
3.6 VDC, 180-AH(ER) 1 minute30 minutes 2 + Years5 minutes 1 + Years
3W Solar Panel (w 10-AH(IR)) 30 Seconds 30 Seconds 3 + Years (*)
8W Solar Panel (w 10-AH(IR)) 10 Seconds 10 Seconds 3 + Years
* Continuously operating up to 7 days without sunlight
Cellular Module
IR= Internal Rechargeable Battery, INR= Internal Non-rechargeable Battery
Creating the Future of Our Water