FLEXIBLE LOW-VOLTAGE, HIGH SAFETY CABLESNon Fire-Propagating.
EXZH
ELLE
NT
XX
I RZ1
-K (A
S) 0
,6/1
kV
APPLICATIONS AND MAIN CHARACTERISTICS
1. The EXZHELLENT XXI RZ1-K (AS) cable series is made up of flexible, single and multi-pole 600/1000 V cables. The maximum service temperature of the cable is 90 ºC and it is able to work at very low temperatures (-40 ºC).
2. As of the 50 mm2 cross-section (inclusive), the SECTORFLEX configuration is available with a flexible sectori-al conductor that, with the same electrical properties and the same conventional terminals and accessories as the circular cable, provides a smaller cable diameter and weight that significantly increase its ease of handling and installation.
3. The High Safety (HS) cables are Non Flame or Fire-Propagating, offer low opacity of smoke emitted, are halogen-free and provide low acidity and corrosiveness of the gases emitted during combustion.
4. They are essential in general installations requiring a higher degree of safety for people and equipment, such as shopping centres, hospitals and schools, etc.
GENERAL INSTALLATIONS
PUBLIC PLACES
NON FIREPROPAGATING
LSOH HALOGEN-FREE
FLEXIBILITY
SECTORFLEX
SAVING ON INSTALLATION TIME
EXZHELLENT XXIRZ1-K (AS) 1000V
VOLTAGE: 0,6/1 kV
CONSTRUCTION
RZ1-K
1 Conductor:Copper, flexible class 5.
2 Insulation:Cross-linked polyethylene (XLPE).Halogen-free.
3 Outer sheath: Halogen-free thermoplastic polyolefin.
· Smaller diameter (-10%)
· Use of conventional terminals and accessories.
ADVANTAGES OF SECTORFLEX
· Lighter weight (-11%) · Easier to install and lay.
NON FLAME PROPAGATIONEN 60332-1-2IEC 60332-1-2
FLEXIBILITY
NON FIRE PRO-PAGATION
EN 60332-3-24IEC 60332-3-24
HALOGEN FREEEN 50267-2-1IEC 60754-1
LOW ACIDITY EN 50267-2-2.3
IEC 60754-2
LOW TEMP.-40ºC
LOW SMOKE EMISSION
EN 61034-2IEC 61034-2
SECTOR SHAPED CONDUCTOR SECTORFLEX
STANDARDS:
STANDARDS
UNE 21123-4 / IEC 60502-1
EN 60332-3-24 / IEC 60332-3-24
EN 60332-1-2 / IEC 60332-1-2
EN 50267 / IEC 60754
EN 61034-2 / IEC 61034-2
Construction standards and testing.
Non fire-propagating.
Non flame-propagating.
Low acidity and corrosiveness of gases. Halogen content.
Low opacity of smoke emitted.
1992206
1992207
1992208
1992209
1992210
1992211
1992212
1992213
1998214
1998215
1998216
1998217
1998218
1998219
1998220
2x1,5
2x2,5
2x4
2x6
2x10
2x16
2x25
2x35
2x50
2x70
2x95
2x120
2x150
2x185
2x240
8,6
9,4
10,5
11,6
13,5
15,5
18,8
21,8
21,3
24,7
27,7
31,3
34,5
37,8
43,3
100
130
170
220
330
465
700
980
1.150
1.590
2.060
2.620
3.230
3.920
5.180
35
40
45
50
55
65
75
90
85
100
140
160
175
190
220
24
33
45
57
79
105
123
154
188
244
296
348
404
464
552
27
36
46
58
77
100
128
154
183
224
265
302
342
383
442
23,61
14,20
8,839
5,919
3,458
2,218
1,458
1,057
0,759
0,556
0,438
0,358
0,302
0,262
0,215
29,37
17,62
10,93
7,288
4,218
2,672
1,723
1,224
0,852
0,601
0,455
0,356
0,285
0,234
0,177
1992110
1992111
1992112
1992113
1992114
1992115
1992116
1992117
1992118
1992119
1992120
1992121
1992122
1992123
1992124
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x630
8,2
9,2
10,8
11,9
13,5
15,6
17,4
19,4
21,4
23,3
26,6
30,2
34,8
39,5
43,7
140
195
285
380
520
715
925
1.170
1.445
1.745
2.300
2.895
3.935
5.050
6.575
35
40
45
50
55
65
70
80
90
95
135
155
175
200
220
68
91
116
144
175
224
271
314
363
415
490
563
674
774
890
77
100
128
154
183
224
265
302
342
383
442
500
570
660
735
3,484
2,240
1,476
1,073
0,773
0,568
0,449
0,368
0,311
0,270
0,223
0,193
0,164
0,146
0,128
4,218
2,672
1,723
1,224
0,852
0,601
0,455
0,356
0,285
0,234
0,177
0,142
0,107
0,085
0,063
CHARACTERISTICS:
Code
Composition no. conduct. x
(mm2)
Outer diameter
(mm)Weight (kg/km)
Min. bend radius (mm)
Air current 40 ºC
(A)
Buried current 25 ºC
(A)
Voltage drop
cos_=0.8 (V/A.km)
Voltage drop
cos_=1 (V/A.km)
1992406
1992407
1992408
1992409
1992410
1992411
1992412
1992413
1998414
1998415
1998416
1998417
1998418
1998419
1998420
4x1,5
4x2,5
4x4
4x6
4x10
4x16
4x25
4x35
4x50
4x70
4x95
4x120
4x150
4x185
4x240
9,9
10,9
12,2
13,5
15,8
18,3
22,4
25,6
27,5
32,3
35,9
40,7
44,9
49,4
56,6
140
185
255
340
525
760
1.150
1.595
2.065
2.885
3.735
4.765
5.890
7.180
9.480
40
45
50
55
65
75
90
130
140
165
180
205
225
250
340
20
26
36
46
65
87
110
137
167
214
259
301
353
391
468
23
30
38
48
64
82
106
129
152
187
222
253
286
320
370
23,61
14,199
8,839
5,919
3,458
2,218
1,458
1,057
0,759
0,556
0,438
0,358
0,302
0,262
0,215
29,37
17,62
10,932
7,288
4,218
2,672
1,723
1,224
0,852
0,601
0,455
0,356
0,285
0,234
0,177
CHARACTERISTICS:
1992306
1992307
1992308
1992309
1992310
1992311
1992312
1992313
1998314
1998315
1998316
1998317
1998318
1998319
1998320
3x1,5
3x2,5
3x4
3x6
3x10
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
9,0
9,9
11,1
12,3
14,3
16,5
20,0
23,3
24,9
29,2
32,5
36,7
40,6
44,3
50,8
115
155
205
275
415
600
905
1.265
1.550
2.160
2.790
3.545
4.395
5.315
7.020
40
40
45
50
60
70
80
95
100
150
165
185
205
225
305
20
26
36
46
65
87
110
137
167
214
259
301
353
391
468
23
30
38
48
64
82
106
129
152
187
222
253
286
320
370
23,61
14,199
8,839
5,919
3,458
2,218
1,458
1,057
0,759
0,556
0,438
0,358
0,302
0,262
0,215
29,37
17,62
10,932
7,288
4,218
2,672
1,723
1,224
0,852
0,601
0,455
0,356
0,285
0,234
0,177
Code
Composition no. conduct. x
(mm2)
Outer diameter
(mm)Weight(kg/km)
Min. bend radius (mm)
Air current 40 ºC
(A)
Buried current 25 ºC
(A)
Voltage drop
cos_=0.8(V/A.km)
Voltage drop
cos_=1(V/A.km)
CHARACTERISTICS:
1992506
1992507
1992508
1992509
1992510
1992511
1992512
1992513
1992514
1992515
1992516
1992517
1992518
1992519
1992520
5x1,5
5x2,5
5x4
5x6
5x10
5x16
5x25
5x35
5x50
5x70
5x95
5x120
5x150
5x185
5x240
10,8
11,9
13,4
14,9
17,5
20,2
24,8
28,4
33,1
39,0
43,4
49,4
54,7
60,3
69,1
170
225
315
420
645
930
1.410
1.950
2.735
3.870
4.985
6.350
7.975
9.755
12.835
45
50
55
60
70
85
100
145
170
195
220
250
330
365
415
20
26
36
46
65
87
110
137
167
214
259
301
353
391
468
23
30
38
48
64
82
106
129
152
187
222
253
286
320
370
23,61
14,199
8,839
5,919
3,458
2,218
1,458
1,057
0,759
0,556
0,438
0,358
0,302
0,262
0,215
29,37
17,62
10,932
7,288
4,218
2,672
1,723
1,224
0,852
0,601
0,455
0,356
0,285
0,234
0,177
Code
Composition no. conduct. x
(mm2)
Outer diameter
(mm)Weight(kg/km)
Min. bend radius(mm)
Air current 40 ºC
(A)
Buried current 25 ºC
(A)
Voltage drop
cos_=0,8(V/A.km)
Voltage drop
cos_=1(V/A.km)
Edit
ion
: Apr
il 20
10
FRANCETel.: +33 (0)1 60 57 30 [email protected]
ITALYTel.: +39 02 660 [email protected]
NORWAYTel.: +47 64955900 [email protected]
PORTUGALTel.: +351 219 678 [email protected]
UNITED KINGDOMTel.: +44 1244 893 245 [email protected]
RUSSIATel.: +7 495 617 [email protected]
ABU DHABITel.: +971 -2- 6338991 [email protected]
ALGIERSTel.: +213 21676174/[email protected]
GERMANYTel.: +49 4731 82 [email protected]
BISKRATel.: +213 33754321/[email protected]
EGYPTTel.: +2017 38 5555 [email protected]
SPAINTel.: 93 227 97 00 [email protected]
Casanova, 150 - 08036 Barcelona (Spain)
www.generalcable.es
Ваш поставщик:
ООО "КОМПАНИЯ ОПТУЛС"Москва, ул. Иловайская, д.3
Тел.: +7 (495) 646-00-96