FLEX SERIES™ HP FLEX SERIES™ The patented series of modular packaged chiller and heat pump with scroll compressors and R-410A refrigerant oriented towards

higher energy efficiency and low noise emissions.

MODULAR Due to the multiple configuration available, Flex Series™ is suitable for air conditioning any environment. More than 200 compositions are possible and the power range can be increased over time in a simple and economical way, thus following the development of the projects.

ECOLOGICAL The ecological refrigerant gas R-410A is not dangerous for the ozone; it allows high efficiency systems (ODP = 0) and convenient electrical consumption, and therefore, lower emissions of CO2 in the atmosphere. The scroll compressor, optimized for R410A are more efficient, compact and silent.

EFFICIENT The unit assure coefficients ESEER and IPLV extremely high and a perfect continuous response to the installation load variation. FLEX SERIES™ HP single circuit units operating with R410A are characterized by an ESEER clearly superior to the traditional

dual-circuit units operating with R407C.

HIGH PERFORMANCES IN HEAT PUMP OPERATING MODE By the point of view of the energy saving and the new European Vision, the FLEX SERIES™ HP family has been designed to provide the highest energy performances. The unit is characterized by oversized heat exchanger on both source-side and user-side, properly selected to reach the best energy efficiency in heating mode. All the FLEX SERIES™ HP units are ranked in A class for the heat pump

operating mode.

SILENT Due to the special axial fans with owlet or Hy Blade profile of the shovels, Flex Series™ is more silent: it reaches a noise reduction of

6 dB(A) compared to standard axial fans version.

PATENTED Flex Series™ is covered by international patents: External Air Recover® In heat pump mode it allows free heating of external air, avoiding the use of an external heat recovery with an increase of 40% for the COP. Energy Multiplier Water Storager® Regenerative recovery system to increase the power and efficiency by using chilled water storage at medium heat. Hybrid Smart Cooling® With the hybrid smart cooling system the unit can match the load request at any outdoor temperature. Flex Series™ is the only chiller able to increase capacity with the increase of the outdoor temperature.

BASIC VERSIONS C Heat Pump HM Heat pump condensing unit

MH Modular heat pump

ENERGETIC VERSIONS D Partial recovery stainless steel brazed plate type desuperheater, externally insulated.

ACOUSTIC VERSIONS LN Low Noise includes condensing control with variable fan speed regulation up to size 1130 and 2 speed condensing control from size 1140 to 1300 and sound compressors jackets. Compared to basic versions, LN versions allows a reduction of about 2 dB(A) in sound levels. SL Super Low Noise includes condensing control with variable fan speed modulation, oversized coils, muffler on the compressor

delivery lines and soundproof box. Compared to basic versions, SL versions allows a reduction of about 5 Db(A) in sound levels.

HYDRAULIC VERSIONS B/M/A Hydraulic kit including: N.1 or N.2 pumps, available head pressure (B) Low (150 kPa), (M) Medium (250 kPa), (A) High (450 kPa), expansion vessel. SB/SM/SA Hydraulic kit including N.1 pump, available head pressure (B) Low (150 kPa), (M) Medium (250 kPa), (A) High (450 kPa), expansion vessel, buffer tank. XB/XM/XA Hydraulic kit including N.2 pumps, available head pressure (B) Low (150 kPa), (M) Medium (250 kPa), (A) High (450 kPa), expansion vessel, buffer tank.

08/02/2016 Page 2 of 25

FLEX SERIES™ HP

MAIN FEATURES

PERSONALIZATION ON INDUSTRIAL SCALE Medium and high powered cooling units have always been built on order, each time personalized according to the client requirements. Thanks to Flex Series™ , Trane introduces the big mass production into this sector, without renouncing the flexibility obtained thanks

to a more personalized production, on the contrary enforcing it thanks to the concept of modularity.

HIGH ENERGETIC EFFICIENCY All basic modules are fitted out with twinned scroll compressors in order to assure constantly very high classes of energetic efficiency and seasonal energetic indexes (ESEER and IPLV). This allows to perfectly and quickly follow system load variations.

Moreover, the Hybrid Smart Cooling enables to increase to 40% the energetic efficiency.

HYBRID SMART COOLING, A NEW LOGIC TO CHOOSE A COOLING UNIT The choice isn’t anymore at 35°C, but at a lower temperature, as for instance at 30°C. It’s from this temperature on that Hybrid Smart Cooling works and the cooling unit is able to exactly satisfy the system power demand. Hybrid Smart Cooling is the only system in the world which allows to reduce consumption of energy and meanwhile to reduce the initial investment costs. Hybrid Smart Cooling uses water. Anyway consumptions are extremely low. If outdoor temperature is up to a 30°C there is no consumption, at 35°C the water consumption is equal to 7 litres/hour for each cooling kWh produced, increasing to 10 litres/hour for each kWh when the outdoor temperature raises to 45°C. The water requirements can be compared to an evaporative tower (about 7/litres/h kWh) but it is just necessary when the air

temperature is higher than 30°C.

PARTIAL LOAD HIGH EFFICIENCY THANKS TO THE HUGE NUMBER OF CHOKING STEPS Thanks to the combination of multiple machines it is possible to increase efficiencies at partial loads. For the sizes equipped with two compressors of different power, it is possible to obtain 3 capacity steps. This increases partial load efficiency and the seasonal

average efficiencies of the individual machine and the system of n machines.

HIGH PERFORMANCES IN HEAT PUMP OPERATING MODE By the point of view of the energy saving and the new European Vision, the FLEX SERIES™ HP family has been designed to provide the highest energy performances. The unit is characterized by oversized heat exchanger on both source-side and user-side, properly selected to reach the best energy efficiency in heating mode. All the FLEX SERIES™ HP units are ranked in A class for the heat pump

operating mode.

INNOVATIVE COOLING CIRCUIT H setting: reversible cooling circuit entirely made of copper, it includes: refrigerant charging, thermostatic expansion valve (up to size 1190 Z) and electronic expansion valve (from size 1200Z up to size 1280 Z) dehydrating filter, liquid indicator, solenoid valve, high and low pressure transducers, high and low pressure switches, 4-ways valve for inversion cycle, liquid receiver and suction coil. The cooling circuits are made up of controlled atmosphere welds and they are evacuated, desiccated, pressure tested, loaded with

precision by means of specially provided electronic instrumentation.

08/02/2016 Page 3 of 25

FLEX SERIES™ HP ELECTRONICS FOR SINGLE UNITS electrical and control panel; made up according to CEI 44-5/IEC 204-2 laws. It includes the isolator door block handle; protection fusibles for compressors, contactors for compressors, protection fusibles for fans, contactors for fans; 220 V auxiliary circuit protection fusibles; 24 V circuit voltage transformer; 24V auxiliary circuit protection; user junction-box with low voltage clamps. The unit is equipped with FG7 cables, with a very good behaviour in an outside installation thanks to their resistance to UV exposure, more higher in comparison with others standard cables. Microprocessor A multi-function 6 button controller with graphic display to set up the adjustment set point of the device power; to monitor the system analog state variables (in/out water temperature, pressure); to monitor the implement state (on-off compressors, valves, antifreeze strengths, etc.); to read the text and code of the activated alarm; to switch on/off the unit and change the function cycle; to change the device function parameters and through password input: proportional calling band of power steps, on-off compressor timing, antifreeze timing (for heat pumps), intervention threshold for antifreeze protection, eventual ventilator speed regulation curve in function of the condensation pressure, etc. ALARM MANAGEMENT: the user interface provides complete information about the unit state and the possibility to decode in a direct and easy way eventual alarm situations, such as: lack of water flow; high/low pressure; thermal compressor; thermal ventilator; broken/ unrelated temperature/pressure drill, etc. CONNECTIONS: Through the contacts (with standard equipment) over the electric panel, it is possible to manage the unit fundamental functions in remote mode: to switch on/off the unit; to select the function cycle (heating and cooling) in remote mode for heat pump versions; to detect the activation of the external water pump; to detect the general state alarm over the device; to detect the compressor on/off state. The controller can be interfaced to a supervisor software via a local or remote PC (via modem), or through complex BMS systems using Modbus protocol.

ELECTRONICS FOR MODULAR APPLICATIONS Flex Series™ , for the modular installations, is equipped with the most innovative control system: Trane applies the most recent hardware technology avalaible on the market and has developed its own control software, properly implemented for this product line, with the purpose to maximize efficiency and performances. 16 bit microprocessors with a 2MB storage capacity, real time clock in order to have an alarm archive, multilingual control software. Conceived to be inserted into a local network of electronic cards for the coordinated management of many cooling circuits on the basis of a single power regulation probe, with diversified control and alarm signals of condensation which just stop their circuit instead of the whole network. The card addressed as master calls the power steps allotted on the whole system and manages the general alarms. The slave cards manage their own compressors according to the timing suggested by the master one, to condensation and to their circuit alarms. It is possible to manage each single network card by means of a unique 6 buttons terminal with LCD graphical display; to set the device power regulation setpoint; to monitor the analogical variables of the system status (in/out water temperatures, pressure on each circuit); to monitor the actuators status on each circuit (on/off compressors, antifreeze resistances, etc.); to read text and code of the intervened alarm; to switch on/off the unit and to change the functioning cycle; to modify the functioning parameters of the device by means of the input of a password: proportional calling band of power steps, on/off compressors timing, defrosting timing (for heat pumps), intervention threshold of antifreeze protection, possible regulation curve of fans speed depending on the condensation pressure, pre-starting timing and post switching off of the water circulation pump. There are three types of alarms: SERIOUS ALARMS: managed by a master card, they have as consequence the deactivation of the whole system, warning on the display, alarm buzzer, relay exit activation of the general alarm (mail on the master card). They are: lack of water flow; possible warning of serious alarm on digital input (lack/inversion of the triad of power supply voltages of the machine, current leakage to ground). CIRCUIT ALARMS: they deactivate only the circuit where they have occurred, give a text alarm on the display, activate the buzzer and the general alarm output relay fitted on the master card. They are: high/low pressure; compressor thermal protection; fans thermal protection; temperature or pressure probe failure; SIGNAL-ONLY ALARMS: they only give a signal text on the display and activate the general alarm output relay fitted on the master card, but they don't deactivate any circuit of the machine. They are: unit maintenance time; compressor maintenance time; water pump maintenance time; net self-control failure: for the multi-card cooling units, this means that one ore more slave-addressed cards are off-line.

UNIT DESCRIPTION

SCROLL COMPRESSORS Hermetic scroll compressors, complete with a heating protection of the electric engine with automatic reinsertion and a crankcase resistance in order to prevent the refrigerant thinning in the oil during device downtimes.

The junction-box is contained into a covering with an IP 54 protection degree.

08/02/2016 Page 4 of 25

FLEX SERIES™ HP

FRAME Lattice framework piece of furniture with elements made of varnished zinc-coated steel able to withstand the mechanical stress both during transport and functioning. The high corrosion strength, assured by an epoxy powder based treatment, and the weather events strength allows the outdoor installation. The building shape assures a perfect air transition through finned parcel exchangers and

allows accessibility to internal components so as to simplify repairs and maintenance.

CONDENSING COILS Condenser coils with seamless copper tubes expanded into aluminum corrugated fins . They are of high efficiency type, complete with subcoling circuit which allows an increase of cooling capacity without an increase of the power input. FOR SL VERSIONS: air side high efficiency and low by-pass impact finned parcel exchangers occupying a wide area, with aluminium gills and copper pipes mechanically expanded. The ranks number has increased in order to assure a full load functioning up to an

outdoor temperature equal to 45°C even with a reduced air delivery.

EVAPORATORS Directly expanded braze welded plated, externally isolated with closed cells anti-condensate mat, fitted with antifreeze electrical

resistance driven by thermostat and water differential gear pressure switch.

RECOVERY OF HEAT EXCHANGERS D VERSION: brazed plate heat exchanger with partial recovery (desuperheater), externally insulated.

FANS The technology of ECOPROFILE propeller fans, has blades statically and dynamically balanced, driven directly by the electric motors, closed type, external rotor and thermal protection for outdoor installation. Class F windings, internal protection according to VDE 0730. Ecoprofile are characterized by low speed and "owlet" profile to reduce the effect of vortices, thereby reducing the energy consumed for operation and noise, reducing it by an average of 6dB (A) compared with standard fans. ECOPROFILE ELECTRONIC fans are available as well in the brushless version, which uses brushless electric motors, further improving both power consumption and noise emissions. In addition, these fans provide a continuous adjustment of condensation. Condensing control by variable fans speed modulation is included on all Flex Series™ version up to 1140 Z size. CONDENSING CONTROL IN THE ACOUSTIC VERSIONS: LN (Low Noise) • variable fan speed modulation up to size 1130; • 2 steps condensing/evaporating control control from size 1140 up to size 1300 (Δ/Y); Fan speed is automatically increased if the units works in extreme outdoor conditions. SL (Super Low Noise) • Condensing control with variable fan speed modulation for all the sizes. Fan speed is automatically increased if the units works in extreme outdoor conditions.

08/02/2016 Page 5 of 25

FLEX SERIES™ HP

08/02/2016 Page 6 of 25

GENERAL TECHNICAL DATA

1105 Z 190 Z 180 Z 170 Z 165 Z 150 Z 145 Z 140 Z MODEL

104,9 89,4 82,8 72,6 64,9 47,5 43,8 38,4 kW Total capacity in cooling mode

40,5 35,4 27,8 23,9 23,5 19,1 16,2 15,0 kW Compressors power input in cooling mode

2,41 2,33 2,69 2,70 2,60 2,31 2,48 2,33 Total EER

127,8 108,9 96,9 87,7 74,0 59,4 52,0 47,2 kW Total capacity in heating mode

35,2 30,3 25,5 26,1 19,4 16,5 14,1 13,1 kW Compressors power input in heating mode

3,35 3,27 3,40 3,01 3,54 3,29 3,33 3,23 Total COP

COMPRESSORS

2 2 2 2 2 2 2 2 n Compressors number

1 1 1 1 1 1 1 1 n Refrigerant circuits

3 3 2 3 2 3 3 2 n Part load

13,2 13,0 13,0 8,7 7,9 5,6 5,6 3,9 kg Refrigerant charge

13,4 13,4 13,4 6,9 6,6 6,3 6,3 6,0 kg Oil charge

WATER EXCHANGER

18 15 14 12 11 8 8 7 m³/h Water flow

53,6 56,9 48,9 58,2 30,0 49,8 42,3 43,0 kPa Water pressure drop

22 19 17 15 13 10 9 8 m³/h Water flow (PDC)

79,7 84,4 66,8 84,9 38,8 77,8 59,6 65,1 kPa Water pressure drop (PDC)

FANS

2 2 2 2 1 1 1 1 n Fans number

43440 45840 43440 45360 20480 22200 22200 22480 m³/h Air flow

1,50 1,50 1,50 1,50 1,50 1,50 1,50 1,50 kW Power input for each fan

3,00 3,00 3,00 3,00 3,00 3,00 3,00 3,00 A Absorbed current for each fan

SOUND LEVEL

86,0 86,0 85,0 83,0 79,0 79,0 79,0 78,0 db Sound power level (ISO 3744)

db Sound pressure level at 1 m (ISO 3744)

DIMENSIONS AND WEIGHT

2558 2558 2558 2558 1460 1460 1460 1460 mm Length

1100 1100 1100 1100 1100 1100 1100 1100 mm Deepth

2090 2090 2090 2090 1990 199 1990 1990 mm Height

961 889 907 809 587 535 522 507 kg Weight

08/02/2016 Page 7 of 25

FLEX SERIES™ HP

GENERAL TECHNICAL DATA

1230 Z 1200 Z 1190 Z 1180 Z 1160 Z 1150 Z 1130 Z 1120 Z MODEL

229,9 201,6 188,6 176,0 159,9 149,7 132,5 117,3 kW Total capacity in cooling mode

89,8 75,3 77,9 67,3 58,5 54,7 50,2 46,1 kW Compressors power input in cooling mode

2,40 2,48 2,29 2,45 2,54 2,53 2,49 2,39 Total EER

280,0 243,6 234,4 214,5 189,3 176,1 158,0 142,4 kW Total capacity in heating mode

80,4 67,4 67,2 60,5 53,4 49,7 43,4 40,0 kW Compressors power input in heating mode

3,24 3,32 3,27 3,30 3,27 3,25 3,41 3,31 Total COP

COMPRESSORS

3 2 3 2 2 2 2 2 n Compressors number

1 1 1 1 1 1 1 1 n Refrigerant circuits

2 2 2 3 2 3 3 3 n Part load

41,0 40,6 30,6 30,6 30,4 30,2 27,0 20,5 kg Refrigerant charge

21,6 13,4 20,1 13,9 14,4 13,9 13,9 13,4 kg Oil charge

WATER EXCHANGER

39 35 32 30 27 26 23 20 m³/h Water flow

53,4 50,0 58,0 50,5 50,9 50,0 63,0 61,0 kPa Water pressure drop

49 42 41 37 33 31 28 25 m³/h Water flow (PDC)

79,2 73,0 89,6 75,0 71,3 69,1 89,1 90,0 kPa Water pressure drop (PDC)

FANS

4 4 3 3 3 3 2 2 n Fans number

85120 88640 63720 63720 63840 66480 40400 42480 m³/h Air flow

1,50 1,50 1,50 1,50 1,50 1,50 1,50 1,50 kW Power input for each fan

3,00 3,00 3,00 3,00 3,00 3,00 3,00 3,00 A Absorbed current for each fan

SOUND LEVEL

89,0 91,0 88,0 89,0 87,0 87,0 87,0 86,0 db Sound power level (ISO 3744)

db Sound pressure level at 1 m (ISO 3744)

DIMENSIONS AND WEIGHT

2558 2558 3599 3599 3599 3599 2558 2558 mm Length

2200 2200 1100 1100 1100 1100 1100 1100 mm Deepth

2205 2205 2205 2205 2205 2205 2090 2090 mm Height

1830 1620 1514 1406 1387 1333 1038 966 kg Weight

08/02/2016 Page 8 of 25

FLEX SERIES™ HP

GENERAL TECHNICAL DATA

1280 Z MODEL

286,2 kW Total capacity in cooling mode

114,3 kW Compressors power input in cooling mode

2,32 Total EER

354,1 kW Total capacity in heating mode

100,3 kW Compressors power input in heating mode

3,24 Total COP

COMPRESSORS

3 n Compressors number

1 n Refrigerant circuits

2 n Part load

41,9 kg Refrigerant charge

20,1 kg Oil charge

WATER EXCHANGER

49 m³/h Water flow

73,2 kPa Water pressure drop

62 m³/h Water flow (PDC)

112,1 kPa Water pressure drop (PDC)

FANS

6 n Fans number

134400 m³/h Air flow

1,50 kW Power input for each fan

3,00 A Absorbed current for each fan

SOUND LEVEL

92,0 db Sound power level (ISO 3744)

db Sound pressure level at 1 m (ISO 3744)

DIMENSIONS AND WEIGHT

3530 mm Length

2260 mm Deepth

2400 mm Height

2440 kg Weight

08/02/2016 Page 9 of 25

FLEX SERIES™ HP

PERFORMANCE IN COOLING MODE

Twout 140 145

Outdoor air temperature Outdoor air temperature

43 25 30 32 35 40 43 25 30 32 35 40

38,6 41,5 43,3 44,4 47,1 32,1 33,8 36,4 37,9 38,9 41,3 kW Pf 5,0 36,7

17,6 15,9 15,0 14,4 13,1 17,3 16,3 14,7 13,9 13,4 12,2 kW Pa 18,7

6,61 7,12 7,42 7,61 8,07 5,51 5,79 6,23 6,49 6,66 7,07 m³/h qw 6,30

32,8 37,9 41,2 43,3 48,8 30,1 33,3 38,6 41,9 44,1 49,6 kPa dpw 29,7

39,6 42,7 44,5 45,6 48,4 33,0 34,7 37,4 38,9 40,0 42,4 kW Pf 6,0 37,7

17,7 16,0 15,1 14,5 13,2 17,4 16,4 14,8 14,0 13,5 12,3 kW Pa 18,8

6,80 7,32 7,63 7,82 8,30 5,66 5,95 6,41 6,68 6,85 7,27 m³/h qw 6,47

34,6 40,1 43,5 45,8 51,6 31,8 35,2 40,7 44,3 46,6 52,5 kPa dpw 31,4

40,7 43,8 45,7 46,9 49,8 33,9 35,6 38,4 40,0 41,1 43,6 kW Pf 7,0 38,7

17,9 16,2 15,2 14,7 13,3 17,6 16,5 15,0 14,1 13,6 12,4 kW Pa 19,0

6,99 7,52 7,84 8,04 8,54 5,82 6,12 6,58 6,86 7,04 7,48 m³/h qw 6,65

36,6 42,3 46,0 48,4 54,6 33,6 37,1 43,0 46,8 49,3 55,5 kPa dpw 33,1

41,8 45,0 46,9 48,2 51,1 34,8 36,6 39,4 41,1 42,2 44,8 kW Pf 8,0 39,8

18,0 16,3 15,4 14,8 13,4 17,7 16,7 15,1 14,2 13,7 12,5 kW Pa 19,2

7,18 7,73 8,05 8,27 8,78 5,97 6,28 6,77 7,05 7,24 7,69 m³/h qw 6,83

38,6 44,7 48,6 51,2 57,6 35,4 39,2 45,4 49,4 52,1 58,7 kPa dpw 34,9

42,9 46,2 48,2 49,5 52,5 35,7 37,6 40,5 42,2 43,3 46,0 kW Pf 9,0 40,8

18,2 16,4 15,5 14,9 13,6 17,9 16,8 15,2 14,4 13,8 12,6 kW Pa 19,3

7,37 7,94 8,28 8,49 9,02 6,13 6,45 6,95 7,25 7,44 7,90 m³/h qw 7,01

40,7 47,2 51,3 54,0 60,9 37,4 41,4 48,0 52,2 55,0 62,0 kPa dpw 36,8

44,0 47,4 49,5 50,8 53,9 36,6 38,6 41,5 43,3 44,5 47,3 kW Pf 10,0 41,9

18,3 16,6 15,6 15,0 13,7 18,0 17,0 15,3 14,5 13,9 12,7 kW Pa 19,5

7,58 8,16 8,51 8,74 9,28 6,30 6,63 7,15 7,45 7,65 8,13 m³/h qw 7,20

43,0 49,9 54,2 57,1 64,4 39,5 43,7 50,7 55,2 58,1 65,6 kPa dpw 38,9

Twout 150 165

Outdoor air temperature Outdoor air temperature

43 25 30 32 35 40 43 25 30 32 35 40

57,1 61,6 64,2 66,0 70,1 39,6 41,7 45,0 47,0 48,3 51,3 kW Pf 5,0 54,2

25,5 23,1 21,8 20,9 19,0 22,1 20,8 18,8 17,7 17,0 15,4 kW Pa 27,2

9,79 10,56 11,01 11,31 12,02 6,78 7,15 7,72 8,05 8,27 8,80 m³/h qw 9,30

23,2 26,9 29,3 30,9 34,9 34,5 38,3 44,6 48,5 51,2 57,9 kPa dpw 20,9

58,6 63,3 66,0 67,8 72,0 40,7 42,8 46,3 48,3 49,6 52,8 kW Pf 6,0 55,7

25,7 23,3 21,9 21,1 19,2 22,3 20,9 18,9 17,8 17,1 15,6 kW Pa 27,4

10,06 10,85 11,31 11,62 12,35 6,97 7,35 7,93 8,28 8,51 9,05 m³/h qw 9,55

24,5 28,5 31,0 32,7 36,9 36,4 40,4 47,1 51,3 54,2 61,3 kPa dpw 22,0

60,2 65,0 67,8 69,6 74,0 41,7 44,0 47,5 49,6 51,0 54,2 kW Pf 7,0 57,1

26,0 23,5 22,1 21,3 19,3 22,5 21,1 19,1 18,0 17,3 15,7 kW Pa 27,6

10,33 11,14 11,62 11,94 12,70 7,16 7,55 8,16 8,51 8,75 9,30 m³/h qw 9,80

25,8 30,0 32,7 34,5 39,0 38,4 42,7 49,8 54,2 57,3 64,8 kPa dpw 23,2

61,8 66,7 69,5 71,4 76,0 42,8 45,2 48,8 50,9 52,4 55,7 kW Pf 8,0 58,6

26,2 23,7 22,3 21,5 19,5 22,6 21,3 19,2 18,1 17,4 15,8 kW Pa 27,8

10,60 11,45 11,94 12,27 13,05 7,36 7,76 8,38 8,75 8,99 9,57 m³/h qw 10,06

27,2 31,7 34,5 36,4 41,2 40,5 45,0 52,6 57,3 60,5 68,5 kPa dpw 24,5

63,4 68,4 71,4 73,3 78,0 44,0 46,4 50,1 52,3 53,8 57,2 kW Pf 9,0 60,1

26,4 23,9 22,5 21,6 19,6 22,8 21,5 19,4 18,3 17,6 16,0 kW Pa 28,0

10,89 11,75 12,26 12,60 13,40 7,55 7,97 8,61 8,99 9,24 9,83 m³/h qw 10,33

28,7 33,4 36,4 38,4 43,4 42,7 47,5 55,5 60,5 63,9 72,4 kPa dpw 25,8

65,0 70,2 73,2 75,3 80,1 45,1 47,6 51,5 53,7 55,2 58,8 kW Pf 10,0 61,7

26,6 24,1 22,7 21,8 19,8 23,0 21,6 19,6 18,4 17,7 16,1 kW Pa 28,3

11,18 12,08 12,60 12,95 13,78 7,77 8,19 8,86 9,24 9,50 10,12 m³/h qw 10,62

30,2 35,3 38,4 40,5 45,9 45,2 50,2 58,7 63,9 67,5 76,6 kPa dpw 27,3

08/02/2016 Page 10 of 25

FLEX SERIES™ HP Twout 170 180

Outdoor air temperature Outdoor air temperature

43 25 30 32 35 40 43 25 30 32 35 40

73,0 78,4 81,5 83,5 88,3 61,1 64,1 68,9 71,7 73,5 77,6 kW Pf 5,0 69,7

30,5 27,4 25,8 24,8 22,4 27,6 26,0 23,5 22,2 21,3 19,4 kW Pa 32,5

12,52 13,44 13,97 14,31 15,13 10,47 10,98 11,81 12,28 12,59 13,30 m³/h qw 11,95

37,9 43,7 47,2 49,5 55,3 41,1 45,2 52,3 56,6 59,4 66,4 kPa dpw 34,5

75,1 80,6 83,8 85,8 90,8 62,7 65,8 70,7 73,6 75,4 79,8 kW Pf 6,0 71,7

30,7 27,6 26,0 24,9 22,5 27,9 26,2 23,7 22,4 21,5 19,6 kW Pa 32,7

12,87 13,82 14,37 14,72 15,56 10,75 11,28 12,13 12,62 12,94 13,68 m³/h qw 12,29

40,1 46,2 49,9 52,4 58,6 43,4 47,7 55,2 59,8 62,8 70,2 kPa dpw 36,5

77,2 82,8 86,1 88,3 93,3 64,3 67,5 72,6 75,6 77,5 81,9 kW Pf 7,0 73,6

30,9 27,8 26,1 25,1 22,7 28,1 26,4 23,9 22,5 21,7 19,7 kW Pa 32,9

13,24 14,22 14,78 15,14 16,01 11,04 11,59 12,46 12,97 13,29 14,06 m³/h qw 12,63

42,4 48,9 52,8 55,5 62,0 45,7 50,3 58,2 63,1 66,3 74,1 kPa dpw 38,6

79,3 85,1 88,5 90,7 95,9 66,0 69,3 74,5 77,6 79,5 84,2 kW Pf 8,0 75,6

31,1 28,0 26,3 25,3 22,8 28,3 26,6 24,1 22,7 21,9 19,9 kW Pa 33,1

13,61 14,62 15,20 15,57 16,47 11,33 11,90 12,79 13,32 13,66 14,45 m³/h qw 12,98

44,8 51,7 55,9 58,7 65,6 48,1 53,1 61,4 66,5 69,9 78,3 kPa dpw 40,8

81,4 87,5 91,0 93,2 98,6 67,7 71,1 76,5 79,6 81,6 86,4 kW Pf 9,0 77,7

31,3 28,2 26,5 25,4 23,0 28,6 26,9 24,3 22,9 22,1 20,1 kW Pa 33,4

13,99 15,02 15,63 16,01 16,93 11,62 12,21 13,14 13,68 14,03 14,85 m³/h qw 13,34

47,3 54,6 59,0 62,0 69,3 50,7 55,9 64,7 70,2 73,8 82,6 kPa dpw 43,0

83,6 89,8 93,4 95,8 101,3 69,4 72,9 78,4 81,7 83,8 88,7 kW Pf 10,0 79,7

31,5 28,4 26,7 25,6 23,1 28,8 27,1 24,5 23,1 22,3 20,3 kW Pa 33,6

14,39 15,46 16,08 16,48 17,43 11,94 12,55 13,50 14,06 14,42 15,27 m³/h qw 13,72

50,1 57,8 62,5 65,6 73,4 53,4 59,0 68,3 74,1 77,9 87,4 kPa dpw 45,5

Twout 190 1105

Outdoor air temperature Outdoor air temperature

43 25 30 32 35 40 43 25 30 32 35 40

92,3 99,4 103,6 106,4 113,0 74,1 78,3 84,6 88,3 90,8 96,5 kW Pf 5,0 87,7

44,3 39,9 37,5 36,0 32,6 41,6 38,9 34,9 32,7 31,3 28,2 kW Pa 47,2

15,81 17,03 17,76 18,23 19,37 12,70 13,41 14,50 15,14 15,55 16,54 m³/h qw 15,03

41,5 48,1 52,3 55,1 62,2 39,0 43,5 50,9 55,4 58,5 66,2 kPa dpw 37,4

94,8 102,1 106,5 109,3 116,1 76,1 80,4 87,0 90,8 93,3 99,2 kW Pf 6,0 90,0

44,6 40,2 37,8 36,3 32,8 41,9 39,2 35,1 32,9 31,5 28,4 kW Pa 47,5

16,25 17,51 18,26 18,74 19,91 13,05 13,79 14,91 15,57 16,00 17,02 m³/h qw 15,44

43,8 50,8 55,2 58,2 65,7 41,2 46,0 53,8 58,6 61,9 70,0 kPa dpw 39,5

97,3 104,9 109,3 112,3 119,3 78,2 82,6 89,4 93,3 95,9 102,0 kW Pf 7,0 92,4

44,9 40,5 38,1 36,6 33,1 42,2 39,5 35,4 33,1 31,7 28,6 kW Pa 47,8

16,69 17,99 18,76 19,26 20,46 13,41 14,17 15,33 16,01 16,45 17,50 m³/h qw 15,86

46,2 53,6 58,3 61,5 69,4 43,5 48,6 56,9 61,9 65,4 74,0 kPa dpw 41,7

99,9 107,7 112,2 115,3 122,5 80,3 84,8 91,8 95,8 98,5 104,8 kW Pf 8,0 94,9

45,3 40,8 38,4 36,8 33,3 42,5 39,7 35,6 33,4 32,0 28,7 kW Pa 48,2

17,14 18,48 19,27 19,79 21,03 13,78 14,56 15,76 16,45 16,91 17,99 m³/h qw 16,29

48,7 56,6 61,5 64,9 73,3 45,9 51,3 60,1 65,4 69,1 78,3 kPa dpw 44,0

102,5 110,5 115,2 118,3 125,8 82,4 87,0 94,3 98,4 101,1 107,7 kW Pf 9,0 97,3

45,6 41,1 38,7 37,1 33,6 42,8 40,0 35,8 33,6 32,2 29,0 kW Pa 48,5

17,60 18,98 19,79 20,33 21,60 14,16 14,95 16,20 16,90 17,37 18,49 m³/h qw 16,72

51,4 59,7 64,9 68,5 77,4 48,5 54,1 63,4 69,1 73,0 82,7 kPa dpw 46,3

105,1 113,4 118,2 121,4 129,1 84,6 89,3 96,8 101,0 103,9 110,6 kW Pf 10,0 99,9

45,9 41,4 38,9 37,4 33,8 43,0 40,3 36,1 33,8 32,4 29,2 kW Pa 48,9

18,09 19,51 20,34 20,89 22,21 14,56 15,37 16,66 17,38 17,87 19,03 m³/h qw 17,18

54,2 63,1 68,6 72,4 81,8 51,2 57,1 67,1 73,1 77,2 87,5 kPa dpw 48,9

08/02/2016 Page 11 of 25

FLEX SERIES™ HP

Twout 1120 1130

Outdoor air temperature Outdoor air temperature

43 25 30 32 35 40 43 25 30 32 35 40

116,3 125,6 131,1 134,6 142,9 98,0 103,2 111,2 116,0 119,1 126,5 kW Pf 5,0 110,3

54,9 49,5 46,5 44,6 40,3 53,8 50,5 45,4 42,6 40,8 36,8 kW Pa 58,6

19,94 21,52 22,46 23,07 24,50 16,80 17,68 19,05 19,87 20,41 21,68 m³/h qw 18,90

48,5 56,5 61,5 64,9 73,2 42,5 47,1 54,7 59,6 62,8 70,9 kPa dpw 43,6

119,4 129,0 134,6 138,3 146,9 100,6 105,9 114,2 119,1 122,3 130,0 kW Pf 6,0 113,2

55,4 49,8 46,8 44,9 40,6 54,2 50,9 45,7 42,9 41,1 37,1 kW Pa 59,0

20,48 22,12 23,09 23,71 25,19 17,25 18,17 19,58 20,42 20,97 22,28 m³/h qw 19,41

51,1 59,7 65,0 68,5 77,3 44,9 49,8 57,8 62,9 66,3 74,9 kPa dpw 45,9

122,6 132,5 138,3 142,0 150,9 103,3 108,7 117,3 122,3 125,6 133,5 kW Pf 7,0 116,2

55,8 50,2 47,2 45,3 40,9 54,6 51,2 46,1 43,2 41,4 37,4 kW Pa 59,4

21,03 22,73 23,72 24,36 25,89 17,72 18,66 20,12 20,98 21,55 22,90 m³/h qw 19,93

53,9 63,0 68,6 72,4 81,7 47,4 52,5 61,0 66,4 70,0 79,1 kPa dpw 48,4

125,8 136,0 141,9 145,8 155,0 106,0 111,6 120,4 125,6 128,9 137,1 kW Pf 8,0 119,2

56,2 50,6 47,5 45,6 41,2 55,0 51,6 46,4 43,6 41,8 37,6 kW Pa 59,9

21,59 23,35 24,37 25,03 26,60 18,20 19,16 20,67 21,55 22,14 23,53 m³/h qw 20,46

56,9 66,5 72,4 76,4 86,3 49,9 55,4 64,4 70,1 73,9 83,5 kPa dpw 51,0

129,0 139,6 145,7 149,7 159,1 108,7 114,5 123,6 128,9 132,4 140,7 kW Pf 9,0 122,2

56,6 50,9 47,9 46,0 41,5 55,4 52,0 46,8 43,9 42,1 37,9 kW Pa 60,3

22,17 23,97 25,02 25,71 27,33 18,68 19,67 21,23 22,14 22,74 24,17 m³/h qw 21,00

59,9 70,1 76,4 80,6 91,1 52,6 58,4 67,9 73,9 78,0 88,1 kPa dpw 53,8

132,4 143,2 149,5 153,6 163,4 111,6 117,5 126,8 132,2 135,8 144,5 kW Pf 10,0 125,4

57,0 51,3 48,2 46,3 41,8 55,9 52,4 47,1 44,2 42,4 38,3 kW Pa 60,8

22,78 24,64 25,72 26,43 28,11 19,19 20,22 21,82 22,75 23,37 24,85 m³/h qw 21,57

63,2 74,0 80,7 85,2 96,3 55,6 61,6 71,8 78,1 82,4 93,2 kPa dpw 56,7

Twout 1150 1160

Outdoor air temperature Outdoor air temperature

43 25 30 32 35 40 43 25 30 32 35 40

140,8 151,8 158,1 162,2 171,8 125,6 132,0 142,1 148,0 151,9 160,9 kW Pf 5,0 133,8

63,7 57,6 54,3 52,2 47,4 63,3 59,6 53,8 50,7 48,7 44,2 kW Pa 67,7

24,12 26,01 27,10 27,80 29,45 21,53 22,62 24,35 25,37 26,03 27,58 m³/h qw 22,94

39,3 45,7 49,6 52,2 58,6 35,1 38,8 44,9 48,8 51,3 57,6 kPa dpw 35,6

144,5 155,8 162,4 166,6 176,5 128,9 135,5 145,9 152,0 155,9 165,3 kW Pf 6,0 137,3

64,1 58,0 54,7 52,6 47,8 63,8 60,0 54,3 51,1 49,1 44,5 kW Pa 68,2

24,78 26,72 27,85 28,57 30,27 22,11 23,23 25,01 26,06 26,74 28,35 m³/h qw 23,55

41,5 48,3 52,4 55,2 61,9 37,0 40,9 47,4 51,5 54,2 60,9 kPa dpw 37,5

148,3 159,9 166,7 171,1 181,4 132,3 139,1 149,7 156,0 160,1 169,8 kW Pf 7,0 140,9

64,6 58,5 55,1 53,0 48,1 64,3 60,5 54,7 51,5 49,5 44,9 kW Pa 68,7

25,45 27,44 28,61 29,36 31,12 22,70 23,86 25,69 26,77 27,47 29,13 m³/h qw 24,18

43,8 50,9 55,3 58,2 65,4 39,0 43,1 50,0 54,3 57,1 64,3 kPa dpw 39,5

152,2 164,1 171,2 175,7 186,2 135,7 142,7 153,6 160,1 164,3 174,3 kW Pf 8,0 144,5

65,1 58,9 55,5 53,4 48,5 64,8 60,9 55,1 51,9 49,9 45,2 kW Pa 69,2

26,13 28,18 29,38 30,16 31,97 23,29 24,50 26,37 27,49 28,21 29,92 m³/h qw 24,81

46,2 53,7 58,4 61,5 69,1 41,1 45,5 52,7 57,2 60,3 67,8 kPa dpw 41,6

156,2 168,3 175,7 180,3 191,2 139,1 146,4 157,6 164,3 168,6 178,9 kW Pf 9,0 148,2

65,6 59,4 56,0 53,8 48,8 65,3 61,4 55,5 52,3 50,3 45,6 kW Pa 69,8

26,83 28,90 30,17 30,97 32,85 23,90 25,14 27,07 28,22 28,96 30,73 m³/h qw 25,46

48,6 56,5 61,5 64,8 72,9 43,3 47,9 55,5 60,3 63,5 71,5 kPa dpw 43,8

160,2 172,8 180,2 185,0 196,3 142,7 150,1 161,7 168,5 173,0 183,6 kW Pf 10,0 151,9

66,1 59,8 56,4 54,2 49,2 65,8 61,9 55,9 52,7 50,7 46,0 kW Pa 70,3

27,56 29,73 31,01 31,83 33,77 24,55 25,83 27,82 29,00 29,76 31,59 m³/h qw 26,14

51,3 59,7 65,0 68,5 77,1 45,6 50,5 58,6 63,7 67,1 75,6 kPa dpw 46,2

08/02/2016 Page 12 of 25

FLEX SERIES™ HP Twout 1180 1190

Outdoor air temperature Outdoor air temperature

43 25 30 32 35 40 43 25 30 32 35 40

166,0 179,0 186,7 191,8 204,1 147,4 155,1 167,1 174,2 178,8 189,7 kW Pf 5,0 157,7

84,9 76,7 72,1 69,2 62,6 77,6 73,1 66,3 62,6 60,2 54,7 kW Pa 90,3

28,44 30,67 32,00 32,87 34,97 25,26 26,58 28,63 29,85 30,64 32,51 m³/h qw 27,02

44,8 52,1 56,7 59,8 67,7 35,3 39,1 45,4 49,3 52,0 58,5 kPa dpw 40,4

170,4 183,8 191,7 196,9 209,6 151,2 159,2 171,5 178,8 183,5 194,8 kW Pf 6,0 161,9

85,6 77,3 72,7 69,8 63,1 78,2 73,7 66,8 63,1 60,7 55,1 kW Pa 91,0

29,21 31,51 32,87 33,77 35,94 25,93 27,29 29,41 30,66 31,47 33,41 m³/h qw 27,76

47,2 55,0 59,8 63,1 71,5 37,2 41,2 47,9 52,0 54,8 61,8 kPa dpw 42,6

174,8 188,6 196,8 202,2 215,2 155,1 163,3 176,0 183,5 188,4 200,1 kW Pf 7,0 166,1

86,3 77,9 73,3 70,3 63,6 78,8 74,3 67,3 63,5 61,1 55,5 kW Pa 91,7

30,00 32,37 33,76 34,69 36,92 26,60 28,01 30,20 31,48 32,32 34,33 m³/h qw 28,50

49,8 58,0 63,1 66,6 75,4 39,2 43,4 50,5 54,9 57,8 65,2 kPa dpw 45,0

179,4 193,6 201,9 207,5 220,9 159,0 167,4 180,6 188,3 193,3 205,4 kW Pf 8,0 170,5

86,9 78,5 73,8 70,9 64,1 79,4 74,8 67,8 64,0 61,6 55,9 kW Pa 92,4

30,80 33,23 34,66 35,62 37,92 27,30 28,75 31,00 32,32 33,19 35,26 m³/h qw 29,27

52,5 61,1 66,5 70,2 79,6 41,3 45,8 53,2 57,8 61,0 68,8 kPa dpw 47,4

184,0 198,6 207,1 212,9 226,7 163,0 171,7 185,3 193,1 198,4 210,8 kW Pf 9,0 174,9

87,6 79,1 74,4 71,5 64,7 80,0 75,4 68,4 64,5 62,0 56,2 kW Pa 93,1

31,61 34,12 35,58 36,57 38,93 28,00 29,49 31,82 33,18 34,08 36,21 m³/h qw 30,05

55,3 64,5 70,1 74,0 83,9 43,4 48,2 56,1 60,9 64,3 72,6 kPa dpw 50,0

188,7 203,8 212,5 218,4 232,6 167,1 176,0 190,0 198,1 203,5 216,3 kW Pf 10,0 179,5

88,3 79,7 75,0 72,0 65,2 80,6 76,0 68,9 64,9 62,5 56,6 kW Pa 93,8

32,47 35,06 36,56 37,57 40,01 28,76 30,29 32,69 34,09 35,01 37,22 m³/h qw 30,89

58,4 68,0 74,0 78,1 88,6 45,8 50,8 59,2 64,3 67,9 76,7 kPa dpw 52,8

Twout 1200 1230

Outdoor air temperature Outdoor air temperature

43 25 30 32 35 40 43 25 30 32 35 40

201,8 218,2 227,9 234,1 248,8 170,1 178,4 191,4 199,2 204,2 216,4 kW Pf 5,0 191,1

97,9 88,5 83,4 80,1 72,7 86,3 81,5 74,1 70,0 67,4 61,2 kW Pa 104,1

34,58 37,40 39,05 40,12 42,64 29,14 30,58 32,79 34,14 35,00 37,08 m³/h qw 32,75

41,0 48,0 52,3 55,2 62,4 35,5 39,1 44,9 48,7 51,2 57,5 kPa dpw 36,8

207,0 224,0 234,0 240,4 255,5 174,4 183,0 196,4 204,4 209,7 222,2 kW Pf 6,0 196,0

98,6 89,1 84,0 80,8 73,3 87,0 82,2 74,7 70,6 67,9 61,7 kW Pa 104,9

35,50 38,42 40,12 41,22 43,82 29,91 31,39 33,68 35,06 35,96 38,10 m³/h qw 33,61

43,2 50,6 55,2 58,3 65,9 37,4 41,2 47,4 51,4 54,0 60,7 kPa dpw 38,8

212,4 229,9 240,1 246,8 262,4 178,9 187,7 201,6 209,8 215,2 228,1 kW Pf 7,0 201,0

99,4 89,8 84,6 81,4 73,8 87,7 82,8 75,3 71,1 68,4 62,1 kW Pa 105,7

36,44 39,45 41,20 42,34 45,03 30,69 32,21 34,58 36,00 36,92 39,15 m³/h qw 34,49

45,6 53,4 58,2 61,5 69,6 39,4 43,4 50,0 54,1 57,0 64,0 kPa dpw 40,8

217,8 236,0 246,4 253,3 269,4 183,4 192,5 206,8 215,3 220,8 234,2 kW Pf 8,0 206,1

100,1 90,5 85,3 82,0 74,4 88,4 83,4 75,8 71,6 68,9 62,5 kW Pa 106,5

37,40 40,51 42,31 43,48 46,26 31,49 33,05 35,50 36,96 37,91 40,21 m³/h qw 35,39

48,0 56,3 61,4 64,9 73,4 41,4 45,6 52,7 57,1 60,1 67,5 kPa dpw 43,0

223,4 242,1 252,8 259,9 276,6 188,0 197,4 212,1 220,8 226,6 240,4 kW Pf 9,0 211,3

100,9 91,2 85,9 82,6 74,9 89,1 84,1 76,4 72,1 69,4 62,9 kW Pa 107,3

38,37 41,58 43,43 44,65 47,51 32,30 33,91 36,44 37,93 38,92 41,29 m³/h qw 36,30

50,5 59,3 64,7 68,4 77,4 43,6 48,0 55,5 60,1 63,3 71,2 kPa dpw 45,2

229,0 248,3 259,3 266,6 283,8 192,7 202,4 217,5 226,5 232,4 246,6 kW Pf 10,0 216,7

101,6 91,9 86,6 83,2 75,5 89,7 84,7 76,9 72,6 69,8 63,3 kW Pa 108,1

39,41 42,72 44,62 45,88 48,84 33,16 34,82 37,43 38,97 39,99 42,44 m³/h qw 37,29

53,3 62,6 68,3 72,2 81,8 46,0 50,7 58,5 63,4 66,8 75,2 kPa dpw 47,7

08/02/2016 Page 13 of 25

FLEX SERIES™ HP

Twout 1280

Outdoor air temperature Outdoor air temperature

43 25 30 32 35 40 43 25 30 32 35 40

240,5 252,7 271,6 282,8 290,2 307,8 kW Pf 5,0 131,1 123,8 112,6 106,4 102,4 93,1 kW Pa

41,22 43,30 46,55 48,47 49,73 52,75 m³/h qw

51,6 56,9 65,8 71,4 75,1 84,5 kPa dpw

246,7 259,3 278,8 290,4 298,0 316,2 kW Pf 6,0 132,2 124,8 113,5 107,2 103,2 93,8 kW Pa

42,31 44,46 47,81 49,79 51,10 54,22 m³/h qw

54,4 60,0 69,4 75,3 79,3 89,3 kPa dpw

253,1 266,0 286,2 298,0 305,9 324,7 kW Pf 7,0 133,2 125,8 114,3 108,0 104,0 94,5 kW Pa

43,42 45,64 49,10 51,14 52,48 55,71 m³/h qw

57,3 63,3 73,2 79,4 83,6 94,3 kPa dpw

259,6 272,8 293,7 305,8 313,9 333,4 kW Pf 8,0 134,3 126,8 115,2 108,8 104,7 95,1 kW Pa

44,56 46,84 50,41 52,51 53,90 57,23 m³/h qw

60,3 66,6 77,2 83,7 88,2 99,5 kPa dpw

266,2 279,8 301,3 313,8 322,2 342,2 kW Pf 9,0 135,3 127,7 116,1 109,6 105,5 95,7 kW Pa

45,73 48,07 51,75 53,90 55,34 58,79 m³/h qw

63,5 70,2 81,3 88,2 93,0 104,9 kPa dpw

273,0 286,9 309,0 321,9 330,5 351,2 kW Pf 10,0 136,4 128,7 117,0 110,4 106,2 96,4 kW Pa

46,98 49,36 53,18 55,38 56,87 60,43 m³/h qw

67,0 74,0 85,9 93,1 98,2 110,9 kPa dpw

08/02/2016 Page 14 of 25

FLEX SERIES™ HP PERFORMANCE IN HEATING MODE

Ta 140 145

Twout Twout

50 45 40 35 30 55 50 45 40 35 30 55

- 38,6 39,1 39,7 40,4 - - 35,1 35,5 36,0 36,6 kW Pt -5°C -

- 13,8 12,5 11,3 10,2 - - 12,8 11,6 10,5 9,5 kW Pat -

- 6,72 6,80 6,89 6,99 - - 6,11 6,18 6,25 6,34 m³/h qw -

- 32,8 33,6 34,5 35,5 - - 36,0 36,8 37,7 38,7 kPa dpw -

- 41,6 42,3 43,1 43,9 - - 37,8 38,4 39,1 39,8 kW Pt -2°C -

- 13,9 12,6 11,4 10,3 - - 12,9 11,7 10,6 9,6 kW Pat -

- 7,24 7,35 7,47 7,59 - - 6,58 6,68 6,78 6,88 m³/h qw -

- 38,1 39,3 40,5 41,9 - - 41,7 42,9 44,3 45,7 kPa dpw -

- 43,8 44,6 45,5 46,4 - - 39,8 40,5 41,3 42,1 kW Pt 0°C -

- 14,0 12,6 11,4 10,4 - - 13,0 11,7 10,6 9,7 kW Pat -

- 7,62 7,76 7,90 8,04 - - 6,93 7,04 7,16 7,29 m³/h qw -

- 42,2 43,7 45,3 46,9 - - 46,2 47,8 49,4 51,1 kPa dpw -

48,3 49,4 50,7 51,9 53,1 - 44,0 44,9 46,0 47,0 48,1 kW Pt 5°C -

15,6 14,1 12,7 11,6 10,5 - 14,5 13,1 11,8 10,8 9,8 kW Pat -

8,59 8,61 8,81 9,00 9,19 - 7,81 7,82 7,99 8,16 8,33 m³/h qw -

53,6 53,9 56,3 58,8 61,3 - 58,8 58,9 61,5 64,2 66,8 kPa dpw -

50,7 52,0 53,4 54,7 56,1 45,0 46,1 47,2 48,4 49,6 50,8 kW Pt 7°C 49,5

15,6 14,1 12,8 11,6 10,6 16,1 14,5 13,1 11,9 10,8 9,8 kW Pat 17,3

9,02 9,06 9,28 9,50 9,71 7,88 8,19 8,22 8,42 8,61 8,80 m³/h qw 8,65

59,0 59,6 62,5 65,5 68,4 59,8 64,7 65,1 68,3 71,4 74,6 kPa dpw 54,4

Ta 150 165

Twout Twout

50 45 40 35 30 55 50 45 40 35 30 55

- 54,5 55,3 56,2 57,2 - - 44,1 44,7 45,3 46,0 kW Pt -5°C -

- 19,0 17,1 15,5 14,0 - - 16,2 14,6 13,2 12,0 kW Pat -

- 9,50 9,62 9,75 9,90 - - 7,68 7,77 7,86 7,97 m³/h qw -

- 21,1 21,6 22,2 22,9 - - 42,9 43,8 44,9 46,1 kPa dpw -

- 58,9 59,9 61,0 62,2 - - 47,5 48,3 49,1 50,0 kW Pt -2°C -

- 19,1 17,2 15,6 14,2 - - 16,3 14,7 13,3 12,1 kW Pat -

- 10,26 10,42 10,59 10,77 - - 8,28 8,40 8,52 8,66 m³/h qw -

- 24,6 25,3 26,1 27,0 - - 49,7 51,2 52,8 54,4 kPa dpw -

- 62,1 63,3 64,5 65,9 - - 50,0 50,9 51,9 52,9 kW Pt 0°C -

- 19,1 17,3 15,7 14,3 - - 16,4 14,8 13,4 12,2 kW Pat -

- 10,81 11,00 11,20 11,40 - - 8,71 8,86 9,01 9,16 m³/h qw -

- 27,3 28,2 29,3 30,3 - - 55,1 57,0 58,9 61,0 kPa dpw -

68,7 70,3 72,0 73,7 75,4 - 55,3 56,5 57,8 59,2 60,5 kW Pt 5°C -

21,4 19,3 17,5 15,9 14,4 - 18,3 16,5 14,9 13,5 12,3 kW Pat -

12,20 12,25 12,52 12,78 13,05 - 9,83 9,84 10,05 10,27 10,48 m³/h qw -

34,7 35,0 36,6 38,1 39,8 - 70,1 70,3 73,4 76,6 79,8 kPa dpw -

72,2 74,0 75,9 77,8 79,7 56,6 58,0 59,4 60,9 62,4 63,9 kW Pt 7°C 70,4

21,5 19,4 17,6 16,0 14,5 20,3 18,3 16,6 15,0 13,6 12,4 kW Pat 23,8

12,82 12,89 13,20 13,50 13,80 9,90 10,31 10,35 10,59 10,83 11,07 m³/h qw 12,31

38,4 38,8 40,6 42,5 44,4 71,2 77,2 77,8 81,5 85,3 89,0 kPa dpw 35,4

08/02/2016 Page 15 of 25

FLEX SERIES™ HP

Ta 170 180

Twout Twout

50 45 40 35 30 55 50 45 40 35 30 55

71,2 72,0 73,0 74,3 75,8 - - 65,6 66,5 67,4 68,4 kW Pt -5°C 70,5

29,0 26,0 23,4 21,1 19,0 - - 25,8 23,3 21,0 19,1 kW Pat 32,4

12,64 12,54 12,70 12,89 13,12 - - 11,42 11,56 11,70 11,85 m³/h qw 12,33

37,5 36,9 37,8 39,0 40,4 - - 47,5 48,6 49,8 51,1 kPa dpw 35,7

76,3 77,5 78,9 80,4 82,1 - - 70,5 71,7 73,0 74,2 kW Pt -2°C 75,3

28,8 25,9 23,3 21,0 18,9 - - 25,9 23,4 21,2 19,2 kW Pat 32,2

13,56 13,50 13,71 13,94 14,21 - - 12,28 12,47 12,66 12,84 m³/h qw 13,16

43,1 42,7 44,1 45,6 47,4 - - 54,9 56,6 58,3 60,0 kPa dpw 40,7

80,1 81,5 83,1 84,8 86,7 - - 74,1 75,6 77,0 78,4 kW Pt 0°C 78,8

28,7 25,8 23,2 20,9 18,9 - - 25,9 23,4 21,2 19,3 kW Pat 32,0

14,23 14,20 14,46 14,72 15,01 - - 12,91 13,14 13,36 13,57 m³/h qw 13,78

47,5 47,3 49,0 50,8 52,9 - - 60,6 62,8 64,9 67,0 kPa dpw 44,5

90,0 92,1 94,3 96,5 98,9 - 81,6 83,5 85,5 87,5 89,4 kW Pt 5°C 88,0

28,5 25,6 23,1 20,8 18,8 - 28,9 26,1 23,6 21,4 19,5 kW Pat 31,7

16,00 16,05 16,40 16,75 17,11 - 14,49 14,54 14,87 15,18 15,47 m³/h qw 15,38

60,0 60,4 63,1 65,8 68,7 - 76,4 76,9 80,4 83,8 87,1 kPa dpw 55,5

94,5 96,9 99,4 101,8 104,3 83,3 85,5 87,7 90,0 92,2 94,3 kW Pt 7°C 92,2

28,4 25,5 23,0 20,8 18,8 32,2 28,9 26,1 23,7 21,5 19,6 kW Pat 31,6

16,80 16,88 17,28 17,67 18,06 14,57 15,19 15,28 15,65 16,00 16,32 m³/h qw 16,11

66,2 66,8 70,0 73,2 76,6 77,2 84,0 84,9 89,1 93,1 96,9 kPa dpw 60,9

Ta 190 1105

Twout Twout

50 45 40 35 30 55 50 45 40 35 30 55

- 95,3 96,6 98,1 99,7 - - 81,2 82,2 83,3 84,7 kW Pt -5°C -

- 35,3 31,8 28,6 25,8 - - 30,6 27,5 24,7 22,2 kW Pat -

- 16,60 16,80 17,02 17,27 - - 14,14 14,28 14,45 14,66 m³/h qw -

- 44,3 45,4 46,6 47,9 - - 46,9 47,9 49,0 50,4 kPa dpw -

- 102,5 104,3 106,1 108,1 - - 87,3 88,7 90,1 91,7 kW Pt -2°C -

- 35,2 31,8 28,6 25,9 - - 30,6 27,4 24,6 22,1 kW Pat -

- 17,86 18,13 18,41 18,71 - - 15,22 15,41 15,63 15,88 m³/h qw -

- 51,3 52,9 54,5 56,3 - - 54,3 55,7 57,3 59,2 kPa dpw -

- 107,8 109,9 112,0 114,2 - - 91,9 93,4 95,1 96,9 kW Pt 0°C -

- 35,2 31,7 28,6 25,9 - - 30,5 27,4 24,6 22,1 kW Pat -

- 18,78 19,10 19,43 19,77 - - 16,00 16,24 16,50 16,78 m³/h qw -

- 56,7 58,7 60,7 62,9 - - 60,1 61,9 63,8 66,0 kPa dpw -

118,9 121,6 124,5 127,3 130,2 - 101,5 103,6 105,8 108,1 110,5 kW Pt 5°C -

39,1 35,2 31,7 28,7 25,9 - 33,9 30,4 27,3 24,5 22,1 kW Pat -

21,13 21,18 21,64 22,09 22,54 - 18,04 18,05 18,40 18,76 19,12 m³/h qw -

71,8 72,1 75,3 78,4 81,7 - 76,4 76,4 79,4 82,5 85,8 kPa dpw -

124,8 127,8 131,0 134,2 137,4 104,1 106,5 108,9 111,4 114,0 116,6 kW Pt 7°C 121,8

39,0 35,2 31,8 28,7 26,0 37,8 33,8 30,3 27,2 24,5 22,0 kW Pat 43,4

22,17 22,26 22,78 23,28 23,79 18,21 18,93 18,97 19,37 19,78 20,19 m³/h qw 21,30

79,0 79,7 83,4 87,2 91,0 77,8 84,0 84,4 88,1 91,8 95,6 kPa dpw 72,9

08/02/2016 Page 16 of 25

FLEX SERIES™ HP Ta 1120 1130

Twout Twout

50 45 40 35 30 55 50 45 40 35 30 55

- 118,2 119,8 121,4 123,2 - - 106,3 107,7 109,2 110,7 kW Pt -5°C -

- 43,3 39,0 35,2 31,8 - - 39,9 35,9 32,3 29,1 kW Pat -

- 20,60 20,83 21,07 21,33 - - 18,52 18,73 18,94 19,17 m³/h qw -

- 49,9 51,0 52,2 53,5 - - 50,2 51,3 52,5 53,8 kPa dpw -

- 127,1 129,2 131,3 133,4 - - 114,4 116,2 118,1 120,0 kW Pt -2°C -

- 43,3 39,1 35,3 31,8 - - 39,9 35,9 32,3 29,1 kW Pat -

- 22,14 22,46 22,78 23,10 - - 19,93 20,21 20,49 20,78 m³/h qw -

- 57,6 59,3 61,0 62,7 - - 58,1 59,7 61,4 63,2 kPa dpw -

- 133,6 136,0 138,5 140,9 - - 120,3 122,4 124,6 126,9 kW Pt 0°C -

- 43,3 39,1 35,3 31,8 - - 40,0 36,0 32,4 29,1 kW Pat -

- 23,26 23,65 24,03 24,40 - - 20,95 21,29 21,62 21,96 m³/h qw -

- 63,6 65,7 67,9 70,0 - - 64,2 66,3 68,4 70,6 kPa dpw -

147,1 150,4 153,9 157,2 160,5 - 132,7 135,5 138,6 141,6 144,6 kW Pt 5°C -

48,2 43,4 39,1 35,3 31,9 - 44,5 40,0 36,0 32,4 29,2 kW Pat -

26,14 26,20 26,75 27,28 27,79 - 23,58 23,61 24,09 24,56 25,04 m³/h qw -

80,3 80,7 84,1 87,5 90,8 - 81,4 81,6 84,9 88,3 91,7 kPa dpw -

154,2 158,0 161,9 165,7 169,3 136,0 139,2 142,4 145,8 149,2 152,6 kW Pt 7°C 150,4

48,2 43,4 39,1 35,4 31,9 49,6 44,5 40,1 36,0 32,4 29,3 kW Pat 53,6

27,40 27,52 28,15 28,75 29,31 23,78 24,73 24,81 25,35 25,89 26,42 m³/h qw 26,30

88,3 89,1 93,2 97,1 101,0 82,8 89,5 90,0 94,0 98,1 102,1 kPa dpw 81,3

Ta 1150 1160

Twout Twout

50 45 40 35 30 55 50 45 40 35 30 55

- 142,3 144,4 146,6 148,8 - - 132,2 134,1 136,1 138,1 kW Pt -5°C -

- 53,2 48,1 43,5 39,5 - - 49,3 44,6 40,3 36,5 kW Pat -

- 24,80 25,11 25,44 25,76 - - 23,02 23,32 23,62 23,91 m³/h qw -

- 40,3 41,4 42,4 43,5 - - 38,9 39,9 41,0 42,0 kPa dpw -

- 152,8 155,5 158,3 161,0 - - 141,9 144,5 147,1 149,5 kW Pt -2°C -

- 53,2 48,1 43,6 39,6 - - 49,4 44,7 40,4 36,6 kW Pat -

- 26,61 27,04 27,47 27,87 - - 24,73 25,12 25,51 25,89 m³/h qw -

- 46,4 48,0 49,5 50,9 - - 44,9 46,4 47,8 49,3 kPa dpw -

- 160,4 163,7 166,9 169,9 - - 149,1 152,1 155,1 157,9 kW Pt 0°C -

- 53,2 48,2 43,7 39,6 - - 49,5 44,7 40,5 36,6 kW Pat -

- 27,94 28,46 28,96 29,42 - - 25,97 26,44 26,90 27,34 m³/h qw -

- 51,2 53,1 55,0 56,8 - - 49,6 51,4 53,2 54,9 kPa dpw -

176,1 180,3 184,9 189,2 193,2 - 163,9 167,7 171,9 175,9 179,7 kW Pt 5°C -

59,0 53,3 48,3 43,8 39,8 - 55,0 49,6 44,9 40,6 36,8 kW Pat -

31,28 31,41 32,14 32,83 33,46 - 29,12 29,22 29,88 30,52 31,11 m³/h qw -

64,2 64,7 67,8 70,7 73,4 - 62,3 62,7 65,6 68,4 71,1 kPa dpw -

184,4 189,3 194,4 199,3 203,7 167,3 171,8 176,1 180,8 185,3 189,5 kW Pt 7°C 179,4

59,1 53,4 48,4 43,9 39,9 61,0 55,0 49,7 44,9 40,7 36,9 kW Pat 65,6

32,77 32,98 33,80 34,57 35,27 29,25 30,52 30,68 31,43 32,14 32,81 m³/h qw 31,37

70,4 71,3 74,9 78,4 81,6 62,9 68,4 69,1 72,6 75,9 79,1 kPa dpw 64,5

08/02/2016 Page 17 of 25

FLEX SERIES™ HP

Ta 1180 1190

Twout Twout

50 45 40 35 30 55 50 45 40 35 30 55

- 175,6 178,0 180,5 183,0 - - 161,2 163,4 165,7 168,0 kW Pt -5°C -

- 66,4 60,0 54,2 48,9 - - 59,6 54,1 49,1 44,7 kW Pat -

- 30,59 30,95 31,32 31,68 - - 28,08 28,41 28,75 29,09 m³/h qw -

- 50,3 51,5 52,7 53,9 - - 42,4 43,4 44,4 45,4 kPa dpw -

- 188,8 191,9 195,1 198,3 - - 173,1 176,0 179,0 181,9 kW Pt -2°C -

- 66,7 60,2 54,3 49,1 - - 59,8 54,3 49,4 44,9 kW Pat -

- 32,88 33,37 33,86 34,33 - - 30,15 30,60 31,05 31,49 m³/h qw -

- 58,1 59,8 61,6 63,3 - - 48,8 50,3 51,8 53,2 kPa dpw -

- 198,4 202,1 205,8 209,5 - - 181,8 185,2 188,7 192,0 kW Pt 0°C -

- 66,8 60,3 54,4 49,2 - - 60,0 54,5 49,5 45,1 kW Pat -

- 34,55 35,14 35,71 36,28 - - 31,66 32,21 32,74 33,24 m³/h qw -

- 64,1 66,3 68,5 70,7 - - 53,8 55,7 57,6 59,3 kPa dpw -

218,6 223,2 228,4 233,6 238,7 - 199,8 204,3 209,2 213,9 218,3 kW Pt 5°C -

74,3 67,1 60,5 54,7 49,4 - 66,6 60,4 54,9 49,9 45,3 kW Pat -

38,84 38,89 39,72 40,53 41,32 - 35,51 35,60 36,37 37,11 37,80 m³/h qw -

81,0 81,2 84,7 88,2 91,7 - 67,7 68,1 71,1 74,0 76,7 kPa dpw -

229,1 234,4 240,3 246,1 251,8 204,1 209,4 214,5 220,0 225,2 230,1 kW Pt 7°C 223,7

74,4 67,2 60,6 54,8 49,6 73,7 66,7 60,5 55,0 50,0 45,4 kW Pat 82,4

40,71 40,83 41,77 42,70 43,59 35,68 37,20 37,37 38,24 39,08 39,84 m³/h qw 39,11

89,0 89,6 93,7 97,9 102,1 68,4 74,3 75,0 78,6 82,0 85,3 kPa dpw 82,1

Ta 1200 1230

Twout Twout

50 45 40 35 30 55 50 45 40 35 30 55

- 210,7 213,6 216,6 219,6 - - 182,8 185,4 188,0 190,6 kW Pt -5°C -

- 80,2 72,4 65,6 59,4 - - 65,8 59,9 54,6 49,8 kW Pat -

- 36,71 37,13 37,58 38,02 - - 31,85 32,23 32,62 33,01 m³/h qw -

- 44,8 45,9 47,0 48,1 - - 41,1 42,1 43,1 44,1 kPa dpw -

- 226,1 229,9 233,8 237,6 - - 196,4 199,8 203,1 206,4 kW Pt -2°C -

- 80,2 72,5 65,7 59,6 - - 66,2 60,3 55,0 50,2 kW Pat -

- 39,38 39,98 40,57 41,14 - - 34,22 34,73 35,24 35,74 m³/h qw -

- 51,6 53,2 54,8 56,3 - - 47,4 48,9 50,3 51,8 kPa dpw -

- 237,3 241,9 246,5 250,8 - - 206,3 210,3 214,2 217,9 kW Pt 0°C -

- 80,2 72,5 65,7 59,6 - - 66,5 60,6 55,3 50,4 kW Pat -

- 41,34 42,07 42,77 43,43 - - 35,94 36,56 37,16 37,73 m³/h qw -

- 56,9 58,9 60,9 62,8 - - 52,4 54,2 56,0 57,7 kPa dpw -

260,7 266,7 273,2 279,5 285,3 - 227,0 232,1 237,5 242,8 247,8 kW Pt 5°C -

89,0 80,3 72,7 66,0 59,9 - 73,9 67,2 61,2 55,7 50,7 kW Pat -

46,32 46,46 47,51 48,49 49,39 - 40,34 40,43 41,29 42,12 42,90 m³/h qw -

71,4 71,9 75,1 78,3 81,2 - 66,0 66,2 69,1 71,9 74,6 kPa dpw -

273,1 280,0 287,3 294,3 300,7 232,0 237,9 243,6 249,7 255,6 261,2 kW Pt 7°C 265,9

89,0 80,4 72,9 66,1 60,0 81,6 74,1 67,4 61,4 55,9 50,7 kW Pat 98,8

48,53 48,78 49,96 51,07 52,07 40,57 42,27 42,43 43,41 44,34 45,22 m³/h qw 46,49

78,4 79,2 83,1 86,8 90,2 66,7 72,4 73,0 76,4 79,7 82,9 kPa dpw 71,9

08/02/2016 Page 18 of 25

FLEX SERIES™ HP Ta 1280

Twout Twout

50 45 40 35 30 55 50 45 40 35 30 55

- - 266,6 269,9 273,5 277,1 kW Pt -5°C - - 97,8 88,9 81,0 73,9 kW Pat

- - 46,44 46,93 47,45 47,97 m³/h qw

- - 63,5 64,9 66,3 67,8 kPa dpw

- - 286,1 290,7 295,3 299,9 kW Pt -2°C - - 98,5 89,6 81,7 74,5 kW Pat

- - 49,84 50,54 51,23 51,92 m³/h qw

- - 73,2 75,2 77,3 79,4 kPa dpw

- - 300,4 305,8 311,2 316,5 kW Pt 0°C - - 98,9 90,1 82,1 74,9 kW Pat

- - 52,33 53,17 54,00 54,81 m³/h qw

- - 80,7 83,3 85,9 88,5 kPa dpw

- 330,5 337,5 345,1 352,6 359,8 kW Pt 5°C - 109,9 99,9 91,0 82,9 75,5 kW Pat

- 58,73 58,79 60,00 61,18 62,29 m³/h qw

- 101,6 101,8 106,1 110,3 114,3 kPa dpw

338,0 346,2 354,1 362,7 371,1 379,1 kW Pt 7°C 121,4 110,3 100,3 91,3 83,1 75,6 kW Pat

59,10 61,51 61,68 63,06 64,39 65,64 m³/h qw

102,9 111,5 112,1 117,2 122,1 126,9 kPa dpw

ELECTRICAL DATA

MODEL Compressors Fans TOTAL MAX VALUE

F.L.I. F.L.A. L.R.A. E.P. O.C. F.L.I. F.L.A. S.A. F.L.I. F.L.A. S.A.

kW A A kW A A kW A A kW A

140 Z 15,0 24,1 98,0 1,5 3,0 27,1 113,0 26,6 47,0 123,0 16,5

145 Z 16,2 26,0 142,0 1,5 3,0 29,0 157,0 28,4 50,0 167,0 17,7

150 Z 19,1 30,8 147,0 1,5 3,0 33,8 162,3 31,2 55,0 172,0 20,6

165 Z 23,5 37,1 147,0 1,5 3,0 40,1 168,6 35,8 63,0 180,0 25,0

170 Z 23,9 41,3 197,0 3,0 6,0 47,3 221,8 43,6 77,0 238,0 26,9

180 Z 27,8 48,0 170,0 3,0 6,0 54,0 200,0 46,4 82,0 214,0 30,8

190 Z 35,4 56,9 215,0 3,0 6,0 62,9 246,2 53,9 95,0 259,0 38,4

1105 Z 40,5 61,0 260,0 3,0 6,0 67,0 290,9 60,1 106,0 304,0 43,5

1120 Z 46,1 67,3 260,0 3,0 6,0 73,3 297,3 67,6 119,0 317,0 49,1

1130 Z 50,2 75,8 320,0 3,0 6,0 81,8 357,2 77,3 136,0 377,0 53,2

1150 Z 54,7 79,1 320,0 4,5 9,0 88,1 364,3 85,1 150,0 391,0 59,2

1160 Z 58,5 87,3 320,0 4,5 9,0 96,3 372,6 94,8 167,0 408,0 63,0

1180 Z 67,3 101,8 413,0 4,5 9,0 110,8 467,0 101,1 178,0 501,0 71,8

1190 Z 77,9 109,8 260,0 4,5 9,0 118,8 342,2 110,8 195,0 393,0 82,4

1200 Z 75,3 112,7 413,0 6,0 12,0 124,7 481,4 108,9 192,0 515,0 81,3

1230 Z 89,8 135,2 320,0 6,0 12,0 147,2 422,1 141,4 249,0 490,0 95,8

1280 Z 114,3 171,1 413,0 9,0 18,0 189,1 545,1 163,3 288,0 611,0 123,3

08/02/2016 Page 19 of 25

FLEX SERIES™ HP

SOUND POWER LEVEL FULL LOAD

Octave band (Hz)

MODEL 63 125 250 500 1000 2000 4000 8000 Lw

Sound power level (dB) dB(A)

140 Z 55,7 51,7 47,1 42,9 40,5 55,7 38,2 27,2 78,0

145 Z 56,7 52,7 48,1 43,9 41,5 56,7 39,2 28,2 79,0

150 Z 57,1 53,1 48,5 44,3 41,9 57,1 39,6 28,6 79,0

165 Z 56,7 52,7 48,1 43,9 41,5 56,7 39,2 28,2 79,0

170 Z 60,5 56,5 51,9 47,7 45,3 60,5 43,0 32,0 83,0

180 Z 62,5 58,5 53,9 49,7 47,3 62,5 45,0 34,0 85,0

190 Z 63,5 59,5 54,9 50,7 48,3 63,5 46,0 35,0 86,0

1105 Z 63,5 59,5 54,9 50,7 48,3 63,5 46,0 35,0 86,0

1120 Z 63,5 59,5 54,9 50,7 48,3 63,5 46,0 35,0 86,0

1130 Z 64,5 60,5 55,9 51,7 49,3 64,5 47,0 36,0 87,0

1150 Z 64,3 60,3 55,7 51,5 49,1 64,3 46,8 35,8 87,0

1160 Z 64,3 60,3 55,7 51,5 49,1 64,3 46,8 35,8 87,0

1180 Z 66,3 62,3 57,7 53,5 51,1 66,3 48,8 37,8 89,0

1190 Z 65,3 61,3 56,7 52,5 50,1 65,3 47,8 36,8 88,0

1200 Z 68,3 64,3 59,7 55,5 53,1 68,3 50,8 39,8 91,0

1230 Z 66,3 62,3 57,7 53,5 51,1 66,3 48,8 37,8 89,0

1280 Z 69,1 65,1 60,5 56,3 53,9 69,1 51,6 40,6 92,0

08/02/2016 Page 20 of 25

FLEX SERIES™ HP

08/02/2016 Page 21 of 25

FLEX SERIES™ HP

08/02/2016 Page 22 of 25

FLEX SERIES™ HP

08/02/2016 Page 23 of 25

FLEX SERIES™ HP

08/02/2016 Page 24 of 25

FLEX SERIES™ HP

08/02/2016 Page 25 of 25