User Manual

D012-000000

Flat Panel User Manual

May 2015

Daisy Data Displays, Inc. 2850 Lewisberry Road York Haven, PA 17370 717.932.9999

Page 2: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

User Manual

2

1 Disclaimer Daisy Data Displays, Inc. (Daisy) makes no representations or warranties with respect to the contents or use of this manual, and specifically disclaims any express or implied warranties of merchantability or fitness for any particular purpose. Further, DAISY reserves the right to revise this publication and to make changes to its content at any time, without obligation to notify any person or entity of such revisions or changes. Further, DAISY makes no representations or warranties with respect to any DAISY manufactured equipment, and specifically disclaims any express or implied warranties of merchantability or fitness for any particular purpose. Further, DAISY reserves the right to make changes to any and all DAISY manufactured equipment, at any time, without obligation to notify any person or entity of such changes.

1.1 FCC Warning Computing devices and peripherals manufactured by DAISY generate, use, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions in this manual may cause interference to radio communications. Such equipment has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of the FCC Rules, which are designed to provide reasonable protection against radio interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user, at his own expense will be required to take whatever measures may be required to correct the interference. Some components may not have been manufactured by DAISY. If not, DAISY has been advised by the manufacturer of the component that the component has been tested and complies with the Class A computing device limits as described above. Copyright 2009 Daisy Data Displays, Inc. (DAISY) All rights reserved. No part of this publication may be reproduced, photocopied, stored on a retrieval system, or transmitted without express prior written consent.

Daisy Data Displays, Inc. 2850 Lewisberry Road

York Haven, PA 17370 USA Phone (717) 932-9999 Fax (717) 932-8000 www.makeitdaisy.com

May 2015 Edition

Manual Revision 3.0 Part Number D012-000000

Page 3: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

Warranty and Liability

D012-000000 3

1.2 Limited Warranty and Liability Statement To the original purchaser, DAISY hereinafter referred to collectively as SELLER, warrants each of its manufactured products, and all components therein contained to be free from defects in materials and/or workmanship for a period of 12 months from the date of purchase. Should a malfunction or other indication of defect attributable directly to faulty materials and/or workmanship occur, Seller will, at its option, and without charge to the customer for labor and parts, repair or replace the defective product, F.O.B. Seller’s plant, but Seller will not be responsible for freight from Purchaser to Seller’s plant. In no event shall Seller be liable for any loss, inconvenience or damage, whether direct, incidental, consequential or otherwise resulting from abuse, misapplication or modification of the product, improper or faulty power, damage resulting from repairs or alterations performed by unauthorized persons, or conditions resulting from any other equipment attached to the product. Seller assumes no liability for damage occurring in transit due to the product not being returned in its original shipping material. This warranty is exclusive and is in lieu of any warranty of merchantability or fitness for a particular purpose or other warranty of quality whether expressed or implied, except of title and against patent infringement. Correction of nonconformities, in the manner and for the period of time provided above, shall constitute fulfillment of all liabilities of the Seller to the Purchaser with respect to, or arising out of the goods, whether based on contract, negligence, strict tort or otherwise.

1.3 Limitation of Liability The Seller shall not under any circumstances be liable for special or consequential damages, such as, but not limited to, damage or loss of other property or equipment, loss of profits or revenues, cost of capital, cost of purchased or replacement goods, or claims of customers of Purchaser for service interruptions. The remedies of the Purchaser set forth herein are exclusive, and the liability of Seller respect to any contract, or anything done in connection therewith such as the performance or breach thereof, of from the manufacture, sale, delivery, resale, installation or use of any goods covered by or furnished under this contract whether arising out of contract, negligence, strict tort or breach of warranty or otherwise, shall not, except as expressly provided herein, exceed the price of the goods upon which such liability is based. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. Seller makes every effort to provide clear and accurate technical information on the application of its products in the Operator's Manual, and assumes no liability for misuse of the information.

Page 4: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

HAZARDOUS AREA SAFETY METHODS

D012-000000 4

Table of Contents

1 Disclaimer .................................................................................................................................................................... 1

1.1 .... FCC Warning ............................................................................................................................................................... 2

1.2 .... Limited Warranty and Liability Statement .................................................................................................... 3

1.3 .... Limitation of Liability .............................................................................................................................................. 3

2 Hazardous Area Safety Methods: ....................................................................................................................... 6

2.1 .... Theory of Operation ................................................................................................................................................ 6

2.2 .... Division 1: Y-Purge Protection ............................................................................................................................ 6

2.3 .... Division 1: X-Purge Protection ............................................................................................................................ 6

2.4 .... Division 2: Non-Incendive Protection .............................................................................................................. 6

3 Pre-Installation Testing .......................................................................................................................................... 8

3.1 .... Division 1: Y-Purge Testing .................................................................................................................................. 8

3.1.1 Equipment Required ................................................................................................................................................................. 8

3.1.2 Procedure ....................................................................................................................................................................................... 8

3.2 .... Division 1: X-Purge Test ...................................................................................................................................... 10

3.2.1 Equipment Required .............................................................................................................................................................. 10

3.2.2 Procedure .................................................................................................................................................................................... 10

4 Division 1 Installation .......................................................................................................................................... 12

4.1 .... PAC-Seal Connection Instructions .................................................................................................................. 12

4.1.1 Equipment Required .............................................................................................................................................................. 12

4.1.2 Procedure .................................................................................................................................................................................... 12

4.2 .... Purge Air Line Connection Instructions for Division 1 Y-Purge Systems ....................................... 13

4.2.1 Equipment Required .............................................................................................................................................................. 14

4.2.2 Procedure .................................................................................................................................................................................... 14

4.3 .... Purge Air Line Connection Instructions for Division 1 X-Purge Systems ....................................... 14

4.3.1 Equipment Required .............................................................................................................................................................. 14

4.3.2 Procedure .................................................................................................................................................................................... 14

5 Start-Up Operation ................................................................................................................................................ 16

5.1 .... Division 1 Y-Purge Start-Up Operation ......................................................................................................... 16

5.2 .... Division 1 X-Purge Start-Up Operation ......................................................................................................... 16

Page 5: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

HAZARDOUS AREA SAFETY METHODS

D012-000000 5

6 Operation Notes...................................................................................................................................................... 18

6.1 .... Division 1 Y-Purge ................................................................................................................................................. 18

6.2 .... Division 1 Y-Purge ................................................................................................................................................. 19

7 Customer Service ................................................................................................................................................... 22

8 Trouble-Shooting Guide ...................................................................................................................................... 23

8.1 .... Division 1 Y-Purge Trouble Shooting ............................................................................................................ 23

8.2 .... Division 1 X-Purge Trouble Shooting ............................................................................................................ 24

9 Specifications ........................................................................................................................................................... 26

10 Revision History ..................................................................................................................................................... 27

THIS PAGE LEFT BLANK INTENTIONALLY ................................................................................................................ 28

11 Drawings ................................................................................................................................................................ ... 29

Page 6: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

HAZARDOUS AREA SAFETY METHODS

D012-000000 6

2 Hazardous Area Safety Methods: 2.1 Theory of Operation [What do Y Purge and X Purge protections have in common? Is there something that summarizes the significance of both protective devices in hazardous areas? ]

2.2 Division 1: Y-Purge Protection Y-purge systems are used for installing electrical equipment in Division 1 hazardous areas*. By installing a Y-purge on an enclosure in a Division 1 area, the rating inside of the enclosure can be reduced to a Division 2 classification. As a result, less costly Division 2 electronic equipment can be safely used in Division 1 areas. A Y-purge system provides the protective purge and safe gas flow to the enclosure. This system is controlled by the operator, in place of the automatic control provided by X purge systems. To provide more alerts for the operator, the purge system includes alarm contacts, a visible indicator to alert the user and if applicable, an automated control system. This control system is important if pressure is lost within the enclosure, which may be caused by a failure of the protective safe gas flow or of enclosure integrity. Prior standards required four volumes of air to be circulated through the enclosure. Now, the standards require that the volume of air passed through a given enclosure eliminate any possible flammable concentration of substances within the enclosure (the minimum of four volumes of exchange still applies). Factory Mutual Class Number 3620 (section 4.2, page 5) states that when “concern exists that all compartments may not be purged, purging tests shall be conducted.” Thus, it is necessary to take into consideration the airflow, pressure, shape of the enclosure and effect of equipment installed within the enclosure. Please note that DAISY’s systems have been fully tested under the supervision of Factory Mutual to ensure compliance with the standards of FM 3620: 4.2, and include all of the features described above. *See National Electrical Code articles 500-504 and the NFPA 496, section 2-9.

2.3 Division 1: X-Purge Protection X-purge systems are used for installing electrical equipment in Division 1 hazardous areas. By installing an X-purge system on an enclosure in a Division 1 area, the area can then be considered a non-rated environment. As a result, normally rated equipment may be installed within the enclosure (within reasonable limits, such as complying with temperature and power restrictions). An X-purge system is fully automated. The system not only provides the protective purge and maintains positive pressure, but it also automatically controls the connection and disconnection of power supplies and signal paths. A well-designed X-purge system also automatically controls flow rates, internal pressure regulation, purge timing, and switching of states between purge flow and normal operation. Please note that DAISY’s systems have been fully tested under the supervision of Factory Mutual to ensure compliance with the standards of FM 3620: 4.2, and include all of the features described above.

2.4 Division 2: Non-Incendive Protection The NEC defines a non-incendive circuit as “one other than field wiring, in which any arc or thermal effect produced under intended operating conditions of the equipment is not capable, under specified test conditions, of igniting the flammable gas-air, vapor-air or dust-air mixture.” Non-incendive circuit designs do not take component failure into consideration, and therefore

Page 7: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

HAZARDOUS AREA SAFETY METHODS

D012-000000 7

have a reduced safety level compared to IS circuit design. They can be worked on while energized without a hot-work permit. Non-incendive devices can be rated for Division 2 as well as Zone 2 areas without a purge control or other protective device. Please note that DAISY’s systems have been fully tested under the supervision of Factory Mutual to ensure compliance with the standards, and are approved as non-incendive devices for all Division 2 areas. *Part of the NEC definition of Division 2 areas.

Page 8: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

PRE-INSTALLATION TESTING

D012-000000 8

3 Pre-Installation Testing Before installing your system in its final location, the system should be tested to verify that the purge system is functioning correctly.

Please note that all pre-installation testing should always be conducted in a safe area.

3.1 Division 1: Y-Purge Testing

3.1.1 Equipment Required • Clean, dry purge air or inert gas supply equipped with local water/oil separator or filter

capable of supplying 150 SCFH at 20 - 100 PSI • Fittings and tubing for purge air or inert gas supply (0.25” NPT Male to connect to the

inlet of the purge system) • Local air pressure shutoff valve

3.1.2 Procedure 1. Place the unit in a safe area near a source of the purge gas to be used (compressed air

line or other inert gas source). 2. Through a cord grip or other cable-sealing device, bring AC power into the enclosure.

Be sure that the AC power is off. Connect the AC power temporarily to the Y-purged unit (see drawing E010 or E013 at the end of this manual).

3. Temporarily install a pressure regulator, water/oil separator or filter, shutoff valve, pressure relief valve, and pressure gauge in the purge air or inert gas line (see drawing P002 at the end of this manual.).

4. Bleed the purge air or inert gas line to insure that dirt, moisture, and other contaminants are cleared from the line prior to connecting the line to the unit.

5. Connect the purge gas line to the inlet of the regulator on the Purge Unit. 6. Apply air or inert gas to the enclosure. The enclosure may “swell” slightly as the

internal pressure increases. This is normal and is not a cause for concern. DAISY enclosures are designed to release excess pressure. DO NOT ATTEMPT TO OPEN THE ENCLOSURE WHILE IT IS PRESSURIZED.

7. Turn the control valve to PURGE. Look at the flow meter on the front panel to verify that the flow rate is 150 SCFH. If not, readjust the purge regulator to set the flow to 150 SCFH.

8. If the flow meter does not read 150 SCFH, inspect the enclosure for blockage in the purge gas lines and take appropriate action to clear the blockage. If blockages are not obvious, verify that the purge air or inert gas is clean and dry.

9. Slowly turn the control valve to OPERATE. If the control valve is turned rapidly, the indicator ball in the flow meter may start oscillating. Look at the pressure gauge on the front panel to be certain that the internal pressure is 1.0” of Water Column. If not, reset the adjustment on the exhaust assembly on the so that the pressure gauge reads 1.0” of Water Column.

10. Slowly turn the control valve to PURGE. Make sure that the flow meter reads 150 SCFH. If not, readjust the regulator for 150 SCFH.

11. Slowly return the control valve to OPERATE and apply power to the enclosure. The “Pressure Good” LED should be illuminated green. If not, check the internal pressure, it should be between 0.4” and 10.0” of Water Column. The pressure good led must be illuminated green at this time. If it is not, please consult the factory.

Page 9: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

PRE-INSTALLATION TESTING

D012-000000 9

12. If the “Pressure Good” LED is not illuminated green, the internal pressure is below 0.4” Water Column and the alarm is on. Turn the enclosure power off and repeat steps 2 though 6.

13. Keyboard button legend (See Image and Diagram below)

(Example image: Button style and location may vary per model.)

Button Label Control Function

CPU-Reset Computer Control

Press both buttons simultaneously to power on and off the computer.

OSD Menu/Enter

(On-Screen-Display)

Monitor Settings

Opens the OSD menu and selects/deselects the highlighted item for adjustment.

OSD - Monitor Settings

Moves through the menu or decreases the value of the selected item.

OSD + Monitor Settings

Moves through the menu or increase the value of the selected item.

LCD Power Monitor Power

Turns LCD monitor on and off. Does not affect PC.

Page 10: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

PRE-INSTALLATION TESTING

D012-000000 10

3.2 Division 1: X-Purge Test

3.2.1 Equipment Required • Clean, dry purge air or inert gas supply equipped with local water/oil separator or

filter capable of supplying 40 to 300 SCFH at 30 to 60 PSI. • Fittings and tubing for purge air or inert gas supply (0.25” NPT Male to connect to

the inlet of the purge system). • Local air pressure shutoff valve. • AC power line (with ground) to pigtails (tinned bare wire, stripped 0.25”), 120V,

10A or 240V, 5A

3.2.2 Procedure 1. Place the unit in a safe area near a source of the purge gas to be used (compressed

air line or other inert gas source). 2. Temporarily install a pressure regulator, water/oil separator or filter, shutoff

valve, pressure relief valve, and pressure gauge in the purge air or inert gas line (see drawing P007).

3. Bleed the purge air or inert gas line to insure that dirt, moisture, and other contaminants are cleared from the line prior to connecting the line to the unit.

4. Connect the purge gas line to the inlet of the regulator on the Purge Unit. 5. Remove the cover of the explosion-proof I/O casting (see drawing P007 at the end

of this manual). 6. Connect an AC power line (not plugged into AC power outlet.) to the power

interface board (see drawing P008). For connection location and wiring, see drawing E017.

7. Close all access doors and covers. 8. Apply purge gas to the system by opening the shutoff valve (if installed). Adjust

the pressure regulator on the air-in box (see drawing P008) so that the pressure gauge indicates 35 PSI.

9. Apply AC power to the unit. 10. Once the pressure inside the unit reaches 1.0” Water Column and at least 40 SCFH, the

Purge Status LED will illuminate yellow, indicating that it is purging. If the purge status indicator does not turn yellow, inspect the unit for leakage. The gasketed panels can be checked with a soap solution. If leaks are not obvious, verify that the purge air of inert gas is clean and dry and that the pressure at the inlet is 35 PSI.

11. DO NOT ATTEMPT TO OPEN THE ENCLOSURE WHILE IT IS PRESSURIZED. 12. Note the reading on the Pressure Gauge while slowly turning the Air Input Regulator

up until the purging process stops and the Purge Status LED flashes red with an error code of 2 – 2 (over pressure) or 3 –2 (over flow).

13. Remove AC power from the enclosure for a minimum of 30 seconds. Decrease the pressure reading on the pressure gauge by 5 PSI. This change may vary slightly on some units; if in later testing the unit fails with an over flow error (3-2 blink code), decrease the inlet pressure by another 2 PSI. Note this pressure for use during start-up.

14. Re-apply AC power. The Purge Status LED will illuminate yellow. The system should purge for a minimum of 8 minutes. The time will vary according to the flow rate of the air into the enclosure; lower flow rates will result in a longer purge time.

Page 11: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

PRE-INSTALLATION TESTING

D012-000000 11

15. After the purge is complete, the Purge Status indicator will illuminate green. AC power is now applied to the internal electronics so you should be able to power on the display or PC

16. If the purge status light blinks red, one of several possible errors has been detected. Please refer to Table 2 on page 19Error! Bookmark not defined. for an explanation of the possible error codes.

Page 12: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

DIVISION 1 INSTALLATION

D012-000000 12

4 Division 1 Installation 4.1 PAC-Seal Connection Instructions A conduit seal is necessary for most equipment enclosures in hazardous areas. For Y-purge and X-purge systems, they are always required. Please consult your local code for other circumstances. The sealing compound generally used for PAC-seals is an inorganic, chemically setting, magnesium oxide base material. This compound develops a slight expansion, while hardening into a porcelain-like body. A powder sealing compound is supplied and should only be mixed with water for application. The sealing compound powder has a shelf life of six months when stored in unopened, tightly sealed containers in a dry location at 70°F. Any equipment accidentally splashed with sealing compound should be cleaned with soap and water before the sealing compound cures. Approximately one ounce of sealing compound is needed per cubic inch of space to be filled. Please note to always follow all NEC, NFPA, and local codes when installing conduit and PAC-seals in hazardous areas. All knowledgeable personnel, familiar with national and local codes, must supervise hazardous area equipment installations. In Europe your equipment will most likely be installed with cable and cable glands. Refer to EN 60079-14:2003 and local codes when applicable.

4.1.1 Equipment Required • Four PAC-Seal fittings, 1” NPT or 0.75” NPT for the Y-Purge, 0.75”NPT only for the X-

Purge (2 for conduit connection at the enclosure or I/O casting, 2 for connection in the safe area), or sealing conduits. The PAC Seal and conduit size selected will depend on the size and number of conductors, which must be run to the unit. Check the NEC tables (Chapter 9, Table 4) to determine the conduit size necessary

• Conduit for electrical signals and for electrical power (separate runs), NEC and NFPA approved for use in hazardous areas

• NEC and NFPA approved flexible conduit if needed for difficult installations • Fittings as required for permanent conduit installation NEC and NFPA approved for use

in hazardous areas • Signal cables, power cables, and connectors as required to mate with the equipment

within the enclosure or cast aluminum box • AC power switch for use in the safe area

4.1.2 Procedure 1. Threaded surfaces and pour locations should be cleaned with soap and water and

thoroughly dried before proceeding. 2. On a Y-purge system, no entryway is provided by DAISY for power and signal

conduits. These entries must be made by the end user. Select a point on the enclosure that matches well with the location of the incoming conduit. Be careful to ensure that the point you have selected is free from obstructions within the DAISY enclosure. Being careful to protect the internal electronics, air pathways, and keyboard surface from filings and other debris, drill or punch holes for the installation of the PAC-Seal fitting (1” NPT or 0.75” NPT, depending on application) in the wall of the enclosure.

Page 13: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

DIVISION 1 INSTALLATION

D012-000000 13

3. Install two conduit runs (one signal, one power) between the enclosure (Y-Purge) or the I/O casting (X-Purge) and AC power source (located in a safe area or in an explosion-proof box). See drawing P002 or P007 at the end of this manual.

4. Shake the sealing compound powder well before mixing with water. The recommended mix ratio is 5 parts powder to 1 part clean water, by weight. Place 70°F water into a clean mixing container and gradually add powder to water while mixing. Continue mixing until a uniform consistency is obtained. Mixing may be done with a slow-speed mixer or by hand with a spatula. The minimum amount of water (as specified above) should be used as excess water reduces mechanical strength, increases shrinkage, and delays set time. Failure of the cement to adhere indicates setting has begun, discard cement, do not attempt to re-temper by adding more water.

5. The compound may be applied by pouring, casting, or mechanical dispenser. The sealing compound hardens with an internal chemical-setting action in 18 to 24 hours at ambient temperature. Working time of the sealing compound when the powder is mixed with water is approximately 30 minutes at 70°F. If accelerated curing is desired, low temperature oven drying at 180°F can be used. Do not expose the sealing compound to higher temperatures, constant water immersion, or steam environments while curing. If high humidity resistance is required in the cured product, a moisture-resistant lacquer or silicone coating should be applied to the exposed surfaces.

6. The packing fiber is made from an environmentally safe, non-asbestos material. It is easy to use and forms a positive dam to hold the compound. The fiber is placed around each individual wire or cable at both ends of the cavity for horizontal pouring in the PAC Seal so that the Sealing Compound can encapsulate each completely. For vertical pouring, the packing fiber need only be placed at one end. See drawing P002 at the end of this manual.

7. We recommend a special blend of lubricants, LUBT-2, for use with threaded joints. This lubricant is to be used to prevent galling of the pipe threads when threaded into a coupling, junction box, etc. It insures a quick release and undamaged male and female threads when parts are disassembled. The thread lubricant is high quality lubricant to be used in temperatures ranging from -40° to +50° F. It is recommended for use in a hazardous location. The PAC Seal Compound, packing fiber and LUBT-2 are available from Killark at http://www.killark.com/.

8. For enhanced reliability of the unit, install an AC line conditioner. AC power lines should be no smaller than 14 gauge and have a TRUE EARTH GROUND.

4.2 Purge Air Line Connection Instructions for Division 1 Y-Purge Systems This section applies to the following models: 2513, 2516, 2518, 2613, 2616, 2618, 4513, 4516, 4518, 4613, 4616 and 4618. After the unit has been mounted in its final location in the hazardous area, it must be permanently connected to a purge air or inert gas line and checked for leaks and proper operation of the purge/pressurization system. Only when its pressure integrity has been established should electrical signals and power be brought “live” to the unit. Please note to always follow all NEC, NFPA, and local codes when installing conduit and PAC-seals in hazardous areas. All knowledgeable personnel, familiar with national and local codes, must supervise hazardous area equipment installations.

Page 14: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

DIVISION 1 INSTALLATION

D012-000000 14

4.2.1 Equipment Required • Clean, dry purge air or inert gas supply equipped with local water/oil separator or filter

capable of supplying 150 SCFH at 20 - 100 PSI • Fittings and tubing for purge air or inert gas supply (0.25” NPT Male to connect to the

inlet of the purge system) • Local air pressure shutoff valve

4.2.2 Procedure 1. Mount the enclosure in the location in which it will be installed. This must be near the

source of air or inert gas to be used for the purge system. 2. Install the pressure regulator, water/oil separator or filter, shutoff valve, pressure

relief valve, and pressure gauge in the purge air or inert gas line (see drawing P002). 3. Bleed the purge air or inert gas line to insure that dirt, moisture, and other

contaminants are cleared from the line prior to connecting the line to the unit. 4. Connect the line to the inlet of the regulator on the Purge Unit. 5. Apply air or inert gas to the enclosure. The enclosure may “swell” slightly as the

internal pressure increases. This is normal and is not a cause for concern. DAISY enclosures are designed to release excess pressure. DO NOT ATTEMPT TO OPEN THE ENCLOSURE WHILE IT IS PRESSURIZED.

4.3 Purge Air Line Connection Instructions for Division 1 X-Purge Systems This section applies to the following models: 2563, 2566, 2568, 2663, 2666, 2668, 4563, 4566, 4568, 4663, 4666 and 4668. After the unit has been mounted in its final location in the hazardous area, it must be permanently connected to a purge air or inert gas line and checked for leaks and proper operation of the purge/pressurization system. Only when its pressure integrity has been established should electrical signals and power be brought “live” to the unit. Please note to always follow all NEC, NFPA, and local codes when installing conduit and PAC-seals in hazardous areas. All knowledgeable personnel, familiar with national and local codes, must supervise hazardous area equipment installations.

4.3.1 Equipment Required • Clean, dry purge air or inert gas supply equipped with local water/oil separator or filter

capable of supplying 40 to 300 SCFH at 30 to 60 PSI. • Fittings and tubing for purge air or inert gas supply (0.25” NPT Male to connect to the

inlet of the purge system). • Local air pressure shutoff valve.

4.3.2 Procedure 1. Mount the enclosure in the location in which it will be installed. This must be near the

source of air or inert gas to be used for the purge system. 2. Install the pressure regulator, water/oil separator or filter, shutoff valve, pressure

relief valve, and pressure gauge in the purge air or inert gas line (see drawing P007 at the end of this manual).

3. Bleed the purge air or inert gas line to insure that dirt, moisture, and other contaminants are cleared from the line prior to connecting the line to the unit.

4. Connect the purge gas line to the inlet of the regulator on the Purge Unit.

Page 15: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

DIVISION 1 INSTALLATION

D012-000000 15

5. The PAC-Seals bringing the power and signals to the explosion-proof I/O casting should already be installed. Connect the signal lines to the interlock system (see drawings E018, E019, E022, E025, and E016).

6. Ensure that the power to the AC supply lines is disconnected. Connect the power line(s) to the X-purge system (see drawing E017).

7. If the area can be made safe, you may want to test your connections before closing the explosion-proof I/O casting. If you test the system in place, it is VITAL that you ENSURE THAT THE AREA IS SAFE during the test and FOLLOW ALL APPLICABLE SAFETY PROCEDURES for “hot work” in a hazardous area. You can test connections without purging by holding down the “Bypass Purge” button (see drawing E020) while applying power; you must release the button within 30 seconds of power application to prevent a diagnostic error. When the button is released, power and signals are immediately “live” to the system; you can test operation to make sure that the connections have been made correctly. Disconnect power IMMEDIATELY upon completion of this test to ensure that the unit is not erroneously operated in bypass mode.

8. When the signal and power connections are complete, replace the cover on the I/O casting and secure with the supplied 14 hex-head bolts. Torque these bolts to 7.5 ft. lbs.

Page 16: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

START-UP OPERATION

D012-000000 16

5 Start-Up Operation 5.1 Division 1 Y-Purge Start-Up Operation

1. When the air, signal, and power connections are complete, replace and close all access doors and covers.

2. Turn the Control valve to PURGE. Look at the Flow Meter on the front panel to verify that the flow rate is 150 SCFH. If not, readjust the Purge Regulator to set the flow to 150 SCFH.

3. If the Flow Meter does not read 150 SCFH, inspect the enclosure for blockage in the purge gas lines and take appropriate action to clear the blockage. If blockages are not obvious, verify that the purge air or inert gas is clean and dry.

4. Slowly turn the Control Valve to OPERATE. If the Control Valve is turned rapidly, the ball in the Flow Meter may start oscillating. Look at the pressure gauge on the front panel to be certain that the internal pressure is 1.0” of Water Column. If not, reset the adjustment on the exhaust assembly on the so that the pressure gauge reads 1.0” of Water Column.

5. Slowly turn the Control Valve to PURGE. Make sure that the Flow Meter reads 150 SCFH. If not, readjust the regulator for 150 SCFH.

6. After a 10-minute purge cycle, slowly turn the control valve to OPERATE. 7. Apply power to the enclosure. The Pressure Good LED should be illuminated green. If

not, check the internal pressure: it should be between 0.4” and 10.0” of Water Column. The pressure good led must

8. If the Pressure Good LED is not illuminated green, the internal pressure is below 0.4” Water Column and the Alarm is on. Turn power off to the enclosure and repeat steps 2 though 6.

be illuminated green at this time. If it is not, please consult the factory.

5.2 Division 1 X-Purge Start-Up Operation 1. When the air, signal, and power connections are complete, replace and close all access

doors and covers. 2. Apply AC power. The Purge Status LED will illuminate red. Power is now applied

though the Intrinsic Safety Barriers to the purge/pressurization control circuits only. 3. Apply purge gas to the system by opening the shutoff valve (if installed). If the pre-

installation test has been performed, the air-in pressure regulator will be preset – you should begin the start-up process at the pressure noted during testing. Otherwise, adjust the pressure regulator on the air-in box (see drawing P008) so that the pressure gauge indicates 35 PSI.

4. Once the pressure inside the unit reaches 1.0” Water Column and at least 40 SCFH, the Purge Status LED will illuminate yellow, indicating that it is purging. If the purge status indicator does not turn yellow, inspect the unit for leakage. The gasketed panels can be checked with a soap solution. If leaks are not obvious, verify that the purge air of inert gas is clean and dry and that the pressure at the inlet is 35 PSI (or, if a pre-installation test was completed, at the pressure noted during that test).

5. DO NOT ATTEMPT TO OPEN THE ENCLOSURE WHILE IT IS PRESSURIZED. 6. If the pre-installation test was completed and the unit appears to be functioning

correctly within the same parameters as during the test, you may skip the remaining steps of this procedure.

7. Note the reading on the Pressure Gauge while slowly turning the Air Input Regulator until the Purge Status LED flashes red with an error code of 2 – 2 (over pressure) or 3 –2 (over flow).

Page 17: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

START-UP OPERATION

D012-000000 17

8. Remove AC power from the enclosure for a minimum of 30 seconds. Decrease the pressure reading on the pressure gauge by 5 PSI. This change may vary slightly on some unit; if the unit fails during purging with an over flow error (3-2 blink code), decrease the inlet pressure by another 2 PSI.

9. Re-apply AC power. The Purge Status LED will illuminate yellow. The purge time is set for a minimum of 8 minutes. The time will vary according to the flow rate of the air into the enclosure.

10. After the purge is complete, the Purge Status indicator will illuminate green. AC power is now applied to the internal electronics and the signal relays are closed.

11. If the purge status light blinks red, one of several possible errors has been detected. Please refer to Table 2 on page 21 for an explanation of the possible error codes.

Page 18: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

OPERATION NOTES

D012-000000 18

6 Operation Notes 6.1 Division 1 Y-Purge When using a Y-purge system, it is the operator’s responsibility to disconnect power and signal paths in the event of a purge failure if the pressure in the unit falls below a preset level. DAISY units are equipped with both an indicator light (the “Pressure Good” LED shown on drawing P008) and an internal pressure meter (shown on the same drawing). If the “Pressure Good” indicator is extinguished, or if the internal pressure meter is in the red zone below 1” of water column, the operator should immediately disconnect power and signal connections to the unit using switches in a safe area. DAISY’s Y-purge systems are also equipped with alarm contacts that switch state simultaneously with the “Pressure Good” indicator. These can be connected to an alarm system or supervisory control system to provide further indications to the operator and/or the supervisory system. The operation of the alarm contacts and the “Pressure Good” indicator light is detailed in the flowchart shown in Figure 1 on page 18 and in Table 1 on page 19.

Figure 1 – Y-Purge Alarm Logic

Page 19: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

CUSTOMER SERVICE

D012-000000 19

Power is Pressure is NC1 & NC2 are NO1 & NO2 are Pressure Good LED

Off < 0.4” W.C. Closed Open Off

Off > 0.4” W.C. Closed Open Off

On < 0.4” W.C. Open Closed Off

On > 0.4” W.C. Closed Open On

Table 1 Y-Purge Alarm and Indicator States

6.2 Division 1 Y-Purge X-purge systems are fully automatic. The system safely disconnects power and signal paths in the event of a purge failure. The DAISY purge control also performs automatic self-diagnostics and can report other errors. Table 2 details both the normal conditions and the errors (fatal and non-fatal) that are reported by the purge status LED (see drawing P008, indicated by note 9). Please note that blink codes can be read in forward or reverse; that is, code 2-3 is the same is code 3-2. A “0” in the code column indicates steady (non-blinking) light. The status column indicates the nature of the information being given: “informative” is simply a status indication and no action needs to be taken, “non-fatal” is a condition that can be corrected and operation will then proceed normally, and “fatal” are errors that require that the purge system be shut down before correcting the problem and restarting the purge cycle.

Color Code Meaning Status Recommended Action

Green 0 Operate, purge complete

Informative n/a

Yellow 0 Purge in progress

Informative n/a

Yellow 1-1 Minor over flow

Non-fatal Turn the air in regulator down a few PSI.

Red 0 Waiting to begin purge

Non-fatal Turn the purge gas supply on. If it is on, the enclosure may not be developing enough internal pressure – make sure all doors and access panels are closed. Also, the air inlet pressure may not be high enough – try turning the regulator up.

Red 1-1 System Error Fatal Contact DAISY customer service (see section 7

Page 20: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

CUSTOMER SERVICE

D012-000000 20

Customer Service on page 22 in this manual).

Red 2-1 Under pressure

Fatal Loss of pressure is usually due to a door being opened or failure of the purge gas supply. Check both.

Red 2-2 Over pressure

Fatal Turn the air inlet regulator down at least 5 PSI. Repeat until purge will complete without error. If problems continue, or occur during operation, contact DAISY customer service (see section 7 Customer Service on page 22 in this manual).

Red 3-2 Major over flow

Fatal Turn the air inlet regulator down at least 5 PSI.

Red 3-3 Water detected

Fatal This should only occur if a water sensor option is installed. If it is installed, the unit must be opened and dried completely out. Ensure that no water remains in the unit and that there is no damage to the internal components resulting from the water. In case of serious water incursion, DO NOT ATTEMPT TO REAPPLY POWER TO THE EQUIPMENT; the equipment should be returned to DAISY for evaluation.

Red 4-1 Faulty pressure sensor

Fatal A purge system component has failed. Please contact DAISY customer service (see section 7 Customer Service on page 22 Error! Bookmark not defined.in this manual).

Red 4-2 Faulty flow sensor

Fatal A purge system component has failed. Please contact DAISY customer service (see section 7 Customer Service on page 22 in this manual).

Red 4-3 Short purge switch is stuck

Fatal The “Short Purge” switch on the DIP switch mounting board (see drawing E020) is either shorted or stuck, or the operator has held it down too long while beginning a test. Ensure that there is nothing holding the switch closed or shorting the circuit. If you continue to experience problems, contact DAISY customer service (see section 7 Customer Service on page 22 in this manual).

Page 21: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

CUSTOMER SERVICE

D012-000000 21

Red 4-4 Bypass purge switch is stuck

Fatal The “Bypass Purge” switch on the DIP switch mounting board (see drawing E020) is either shorted or stuck, or the operator has held it down too long while beginning a test. Ensure that there is nothing holding the switch closed or shorting the circuit. If you continue to experience problems, consult DAISY contact DAISY customer service (see section 7 Customer Service on page 22 in this manual).

Table 2 – X-Purge Status Light Key

Page 22: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

GENERAL TROUBLESHOOTING

D012-000000 22

7 Customer Service Chapter 8 has a complete trouble-shooting guide to help you quickly identify any problems that may occur. Should you have any further inquiries or comments, please contact DAISY’s customer service department. Business Phone (1) 717-932-9999 x 222 Fax (1) 717-932-8000 Email [email protected] Equipment returned to DAISY for service must be accompanied by a valid return merchandise authorization (RMA) number. Items or products shipped to DAISY without a valid RMA number will be refused. An RMA will be generated upon receipt of Company Name, Address, Contact, Product Model and Serial Numbers. Typical Model/Serial Number Tag

Daisy Data Displays Inc. prides itself on offering best in class support for your products. Our technical support team can help you with installation, configuration, troubleshooting, and other support issues for all DAISY’ products.

Page 23: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

TROUBLE-SHOOTING GUIDE

D012-000000 23

8 Trouble-Shooting Guide 8.1 Division 1 Y-Purge Trouble Shooting

PROBLEM POSSIBLE CAUSE SUGGESTED SOLUTION

The flow cannot be adjusted up to 150 SCFH during purge

Improper flow meter reading

For correct operation, the purge unit must be mounted vertically so that the flow meter is vertically plumb

Improper regulator adjustment

Adjust the air inlet regulator to increase air supply

The purge control is not set to purge

Check the position of the control valve to ensure that it is set to “Purge”

Insufficient air supply Check your purge gas supply to ensure that it can supply 150 SCFH. If you cannot achieve 150 SCFH, then purge times must be recalculated. Contact DAISY customer service for assistance.

Restrictions in the air supply line

Check your air supply line for blockages and kinks

Contamination in the air supply

Ensure that the purge gas supply is clean, dry, and free of oil – a water/oil separator should be installed near the connection to the purge control

Restrictions in the purge line from the purge control into the enclosure

Ensure that the purge line from the purge control into the enclosure is not kinked, has no internal obstructions, and is unrestricted at its open end (at least 0.5” from any object in the path of the air flow)

During operation (control valve set to “Operate”), the internal pressure does not reach/will not maintain 1” of water column

The enclosure is not sealed and is leaking

Ensure that all access doors are closed and latched. Ensure that all access panels are closed and sealed. Make sure no unsealed holes or openings are present in the enclosure.

Insufficient air flow Adjust the regulator on the purge control to increase the air flow

PAC-Seals are not poured PAC-Seals must be poured in conduits entering the enclosure to prevent air from escaping via the conduit entry. Ensure that this has been done.

Exhaust control valve Adjust the purge control exhaust valve for a

Page 24: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

SPECIFICATIONS

D012-000000 24

setting incorrect higher internal pressure. It may take several minutes for adjustments to this setting to take effect.

During operation (control valve set to “Operate”), the internal pressure does not reach/will not maintain 1” of water column

Restrictions in the air connections

Ensure that the air connection at the regulator is not kinked, has no obstructions, and is firmly connected.

The “Pressure Good” indicator does not light when the unit is powered

Incorrect power-up sequence

Power should only be applied to the enclosure after the internal pressure has reached 1” of water column or higher and when the full purge time has elapsed

Insufficient internal pressure

The pressure within the enclosure must be within the operating (or “safe”) range. If you are having trouble maintaining a suitable pressure, see the previous section of this trouble-shooting guide.

Alarm board is not receiving power

Ensure that AC power has been connected to the unit, and that the power is turned on

Voltage is set incorrectly Ensure that the 120/240 VAC switch on the alarm board is set appropriately for your power source

8.2 Division 1 X-Purge Trouble Shooting PROBLEM POSSIBLE CAUSE SUGGESTED SOLUTION

When power is applied, the purge status indicator light does not come on

Power is not connected to the unit

Connect AC power to the power connection on the purge system. Ensure that the power switch is on. Ensure that AC power is on.

Improper line voltage selection

Ensure that the 120/240 VAC switch on the purge control is set appropriately for your power source.

After power is applied, the purge status indicator stays solid red; it does not switch to yellow or blink

No air supply to unit Ensure that a purge gas line is connected to the unit and that the supply line is “on.” The pressure gauge on the air-in box should indicate a higher pressure than 20 PSI

Restrictions in air line Ensure that supply line and inlet connect have no restrictions and that the supply line is not kinked

Restrictions in main purge line inside enclosure

Ensure that the main purge line (terminating in a brass tee fitting) is not kinked or disconnected

Leaks in the enclosure Ensure that all access doors are closed and latched. Ensure that all access panels are

Page 25: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

SPECIFICATIONS

D012-000000 25

closed and sealed. There should be no holes or openings in the enclosure.

The purge status indicator is yellow, but the enclosure takes an excessively long time to complete the purge (when the status indicator turns green)

Low purge gas supply pressure

Increase purge gas inlet pressure at the air-in regulator or on the main supply line

Restriction in the main purge line

Ensure that the main purge line within the enclosure (ending in a brass tee fitting) is not kinked or obstructed

Purge status indicator flashes yellow and purge takes an excessively long time to complete.

Low purge gas supply pressure

Increase purge gas inlet pressure at the air-in regulator or on the main supply line

Purge or operation stops and purge status indicator flashes red code

Fatal purge error See Table 2 on page 19

Page 26: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

SPECIFICATIONS

D012-000000 26

9 Specifications Materials All materials comply with NEMA 4X standards Enclosure and Hardware ........................................... Stainless Steel Explosion-proof I/O Casting .................................... Cast Aluminum (Division 1 X-purge) Explosion-proof I/O Casting Bolts ......................... Hardened Steel (Division 1 X-purge) Mechanical See drawings for dimensions Environmental Operating Temperature ............................................. -17.78° – +29.4° C (0° – +85° F) Storage Temperature .................................................. -17.78° – +60° C (0°– +140°F) Relative Humidity ......................................................... 5% - 95% RH Non-condensing Electrical Voltage............................................................................... 120/240 VAC Frequency ........................................................................ 60/50 Hz Power (Monitors) ......................................................... 60W Maximum Power (PCs) .................................................................... 360W Maximum Air Requirements NEMA 12 and NEMA 4X ............................................. No air required Division 2 Non-incentive ........................................... No air required Division 1 Y-Purge ........................................................ 150 SCFH Minimum Division 1 X-Purge ........................................................ 40 SCFH Minimum 300 SCFH Optimum 20 - 60 PSI Recommended at Inlet Display (based on 60 Hz refresh frequency) Resolution Maximum .................................................. 1024 x 768 (15”) 1280 x 1024 (19”) 1680 x 1050 (22”) Dot Pitch ........................................................................... 0.297mm (15”) 0.294mm (19”) 0.282 x 0.282mm (22”) Viewable Size .................................................................. 232.664(H) x 308.864mm (V) (15”) 376.32(H) x 301.056mm (V) (19”) 473.76(H) x 296.1mm (V) (22”) Viewing Angle ............................................................... *NOTE Typical Brightness ........................................................ 15” 350-600 nits 19” 300 nits 22” 300 nits Color Depth ..................................................................... 24 bits *NOTE Due to frequent technology changes please call for specific model specifications.

Page 27: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

REVISION HISTORY

D012-000000 27

10 Revision History

REVISION CHANGE DESCRIPTION DATE AUTHOR

3.0 Preliminary 05/01/2015 MR

Page 28: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

D012-000000 28

THIS PAGE LEFT BLANK INTENTIONALLY

Page 29: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

DRAWINGS

D012-000000 29

11 Drawings Drawing Model Description Page M001 2570 Panel Monitors: Mechanical and mounting drawings 32

E001 2573 Panel Mount 15” Monitors: Electrical block diagram 33

E098 2576 Panel Mount 19” Monitor: Electrical block diagram 34

E099 2578 Panel Mount 22” Monitor: Electrical block diagram 35

M018 2550KP/ 4550KP

NEMA4X monitors and PCs: Mechanical and mounting drawings

36

M019 2520KP/ 4520KP

Div. 2 non-incedive monitors and PCs: Mechanical and mounting drawings

37

M006 2650/4350 NEMA 4X integrated monitors and PCs: Mechanical and mounting drawings

38

M007 2620/4320 Div. 2 non-incedive integrated monitors and PCs: Mechanical and mounting drawings

39

P001 2620/2650 4320/4350 2520KP/2550KP 4520KP/4550KP

NEMA 4X and Div. 2 non-incendive monitor and PCs conduit and cable entry drawings

40

E003 2620/2650 2520KP/2550KP

NEMA 4X and Div. 2 non-incendive monitor electrical connection drawings

41

E100 2523KP/ 2553KP

NEMA 4X and Div. 2 non-incendive keypad 15” monitor electrical block diagram

42

E101 2623/2653 NEMA 4X and Div. 2 non-incendive integrated 15” monitor electrical block diagram

43

E102 2526KP/ 2556KP

NEMA 4X and Div. 2 non-incendive keypad 19” monitor electrical block diagram

44

E103 2626/2656 NEMA 4X and Div. 2 non-incendive integrated 19” monitor electrical block diagram

45

E104 2528KP/ 2558KP

NEMA 4X and Div. 2 non-incendive keypad 22” monitor electrical block diagram

46

E105 2628/2658 NEMA 4X and Div. 2 non-incendive integrated 22” monitor electrical block diagram

47

E006 4320/4350 4520KP/4550KP

NEMA 4X and Div. 2 non-incendive PC electrical connection drawings

48

E106 4323/4353 NEMA 4X and Div. 2 non-incendive integrated 15” PC electrical block diagram

49

E107 4523KP/ 4553KP

NEMA 4X and Div. 2 non-incendice keypad 15” PC electrical block diagram

50

E108 4326/4356 NEMA 4X and Div. 2 non-incendive integrated 19” PC electrical block diagram

51

E109 4526KP/ 4556KP

NEMA 4X and Div. 2 non-incendive keypad 19” PC electrical block diagram

52

Page 30: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

DRAWINGS

D012-000000 30

E110 4328/4358 NEMA 4X and Div. 2 non-incendive integrated 22” PC electrical block diagram

53

E111 4528KP/ 4558KP

NEMA 4X and Div. 2 non-incendive keypad 22” PC electrical block diagram

54

M008 2510KP/ 4510KP

Div. 1 Y-Purge monitors and PCs: Mechanical and mounting drawings

55

M009 2610/4310 Div. 1 Y-Purge integrated monitors and PCs: Mechanical and mounting drawings

56

P002 2510KP/2610 4310/4510KP

Div. 1 Y-Purge monitor and PC conduit, cable entry, and air connection drawings

57

P003 2510KP/2610 4310/4510KP

Div. 1 Y-Purge air flow block diagram 58

P004 2510KP/2610 4310/4510KP

Div. 1 Y-Purge front panel diagram and locator drawing 59

P005 2510KP/2610 4310/4510KP

Div. 1 Y-Purge back panel diagram and locator drawing 60

P006 2510KP/2610 4310/4510KP

Div. 1 Y-Purge over pressure exhaust diagram 61

E009 2510KP/2610 4310/4510KP

Div. 1 Y-Purge alarm/logic board diagram and locator drawing

62

E010 2510KP/2610 Div. 1 Y-Purge monitor electrical connection drawings 63

E112 2513KP Div. 1 Y-Purge keypad 15” monitor electrical block diagram

64

E113 2613 Div. 1 Y-Purge integrated 15” monitor electrical block diagram

65

E114 2516KP Div. 1 Y-Purge keypad 19” monitor electrical block diagram

66

E115 2616 Div. 1 Y-Purge integrated 19” monitor electrical block diagram

67

E116 2518KP Div. 1 Y-Purge keypad 22” monitor electrical block diagram

68

E117 2618 Div. 1 Y-Purge integrated 22” monitor electrical block diagram

69

E013 4310/4510KP Div. 1 Y-Purge PC electrical connection drawings 70

E118 4313 Div. 1 Y-Purge integrated 15” PC electrical block diagram

71

E119 4513KP Div. 1 Y-Purge keypad 15” PC electrical block diagram 72

E120 4316 Div. 1 Y-Purge integrated 19” PC electrical block diagram

73

E121 4516KP Div. 1 Y-Purge keypad 19” PC electrical block diagram 74

E122 4318 Div. 1 Y-Purge integrated 22” PC electrical block diagram

75

Page 31: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

DRAWINGS

D012-000000 31

E123 4518KP Div. 1 Y-Purge keypad 22” PC electrical block diagram 76

M010 2560KP/ 4560KP

Div. 1 X-Purge monitors and PCs: Mechanical and mounting drawings

77

M011 2660/4360 Div. 1 X-Purge integrated monitors and PCs: Mechanical and mounting drawings

78

P007 2560KP/2660 4360/4560KP

Div. 1 X-Purge monitor and PC conduit, cable entry, and air connection drawings

79

P008 2560KP/2660 4360/4560KP

Div. 1 X-Purge front panel diagram and locator drawing 80

P009 2560KP/2660 4360/4560KP

Div. 1 X-Purge back panel diagram and locator drawing 81

P010 2560KP/2660 4360/4560KP

Div. 1 X-Purge air flow block diagram 82

E016 2560KP/2660 4360/4560KP

Div. 1 X-Purge electrical block diagram 83

E017 2560KP/2660 4360/4560KP

Div. 1 X-Purge power interface board diagram and locator drawing

84

E018 2560KP/2660 4360/4560KP

Div. 1 X-Purge signal switching board diagram and locator drawing

85

E019 2560/2660 4360/4560KP

Div. 1 X-Purge signal interface board diagram and locator drawing

86

Chart 2560KP/2660 4360/4560KP

Div. 1 X-Purge signal switching board and internal signal interface board connections

87

E020 2560KP/2660 4360/4560KP

Div. 1 X-Purge DIP switch mounting board diagram and locator drawing

88

E021 2560KP/2660 4360/4560KP

Div. 1 X-Purge purge control board diagram and locator drawing

89

E022 2560KP/2660 Div. 1 X-Purge monitor electrical connection drawings 90

E124 2563KP Div. 1 X-Purge keypad 15” monitor electrical block diagram

91

E125 2663 Div. 1 X-Purge integrated 15” monitor electrical block diagram

92

E126 2566KP Div. 1 X-Purge keypad 19” monitor electrical block diagram

93

E127 2666 Div. 1 X-Purge integrated 19” monitor electrical block diagram

94

E128 2568KP Div. 1 X-Purge keypad 22” monitor electrical block diagram

95

E129 2668 Div. 1 X-Purge integrated 22” monitor electrical block diagram

96

E025 4360/4560KP Div. 1 X-Purge PC electrical connection drawings 97

E130 4363 Div. 1 X-Purge integrated 15” PC electrical block diagram

98

Page 32: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

DRAWINGS

D012-000000 32

E131 4563KP Div. 1 X-Purge keypad 15” PC electrical block diagram 99

E132 4366 Div. 1 X-Purge integrated 19” PC electrical block diagram

100

E133 4566KP Div. 1 X-Purge keypad 19” PC electrical block diagram 101

E134 4368 Div. 1 X-Purge integrated 22” PC electrical block diagram

102

E135 4568KP Div. 1 X-Purge keypad 22” PC electrical block diagram 103

E086 2500KP/ 4500KP

Monitor and PC keypad layout 104

E097 2500KP/2600 4300/4500KP

Monitor and PC on screen display keypad layout 105

8985 2753 NEMA 4X 15” flat panel monitor, electrical block diagram

106

8984 2756 NEMA 4X 19” flat panel monitor, electrical block diagram

107

8987 4753KB NEMA 4X 15” flat panel PC, integrated/non-integrated keyboard electrical block diagram

108

8988 4756KB NEMA 4X 19” flat panel PC, integrated/non-integrated keyboard electrical block diagram

109

8990 2723KB Monitor 15”, non-integrated, non-incendive electrical block diagram

110

8989 2726KB Monitor 19”, non-integrated, non-incendive electrical block diagram

111

8991 4723KB Workstation, non-integrated, non-incendive, 15” PC electrical block diagram

112

8993 4726KB Workstation, non-integrated, non-incendive, 19” PC electrical block diagram

113

8997 2576AA Monitor 19”, non-integrated panel mount, non-incendive electrical block diagram

114

8996 4576AA PC 19”, non-integrated panel mount, non-incendive electrical block diagram

115

DAISY03-000439

Modification drawing, 19” ST05 unit, ½“ conduit holes 116

DAISY03-100107

2758KB NEMA 4X 22” flat panel monitor, integrated/non-integrated electrical block diagram

117

DAISY03-100170

4758AA NEMA 4X 22” flat panel PC, electrical block diagram 118

DAISY03-100215

4758KB NEMA 4X 22” flat panel PC, integrated/non-integrated keyboard electrical block diagram

119

Page 33: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

PANEL MOUNT ENCLOSURE ,----------------------------------------------------,

15" I DI35!.,EP lO24x768 POOo-OOOl29

LVDSVIDEO ~~ // P070-000S74 ........ OSD

P070-000481

~ ~ P13o-00000S ~~ ~ ~ ~

I§!!!!l" // VGA

LEDDRNER // Pl3l-000020 .... , ........ P l3l'()OOO03

POOS'()00003 "- " VIDEO CARD POSO-OOO24S I

] VGA DE-IS Mating Cable: P07o-000038

I I

MODEL 2573: NEMA 4X PANELMOUNT FLAT PANEL 15" MONITOR

~~

VIDEO POWER 1I00-0019S8

~

DIMENSIONS ARE IN INCHES

THIS DOCUMENT IS PROPRIETARY TO DAISY DATA. INC.

1I00-001333'()1 , ...... 1101220

PDB

~ <tl'S;C 1047-100050 S&12VDC 12VDC ...

"

I I I I I

POWERINI

1I00-OOIS6~ //

"-

~ POWER IN -llOmOVAC lEC - CI4 (Male Inlet) Mating Cable: EOOO-030000

D' D t I PANEL MOUNT alSY a a, nco 15" ENCLOSURE THE USE OF OR REPRODUCTION OF THIS DOCUMENT IS PROHIBITED EXCEPT AS AUTHORIZED BY JECTRIoobBLoCKDiAGRAMDRA WINd DRA~NG NUMBEOO 1 DAISY DATA IN WRITING_ SPECIFICATIONS A~ SUBJECT TO CHANGE WITHOUT NOTIC ..

We Thrive ill the Harshest Envrromnents VOIce: (717) 932-9999 FAX: (717) 932-8000 or VlSlt Us At www.daisydata.com SHEET 1 OF 1 I""B

Page 34: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

® TABLE 1

"ODEI. l£N01H

sa73 ... .... 0It .... 100"

... 7 150" .... .,.,. .... ....

.570 JOO"

9071 -.572 40CY

157. 500·

NOTES:

TO aJSTOMER INPUT CORD GRIP

;Ie 1&.1 I'=ZI&.II&.I

~~~n~

F ACT'ORY WIRED TO DAISY DATA

EQUIPMENT

CD lHE 120 VAC POIIER INPUT CONNECllON IS LOCATED ON lHE INSIDE REAR WALL IN lHE UPPER LEFT CORNER FOR ALL MODELS SHO\\lOl. USE lHE CONNEC1l0N PIN-OUT OF lHE 6 POSI11ON TERMINAL STRIP.

MODELS I'.1lH lHE "NO KVM INSTALLED" OP1l0N REQUIRE A CUSTOMER SUPPUED HD15 PLUG SVGA VIDEO CABLE CONNECTED TO lHE UNIT. lHE HD15 VIDEO INPUT CONNEC110N IS LOCATED ON lHE REAR OF lHE FRONT DOOR FOR ALL MODELS SHO\\lOl.

SEE TABLE 1 FOR lHE DAISY DATA KVIM CATS INPUT CABLE MODEL NUMBER & LENGlH.

FOR CABLE & CONDUIT ENTRY INTO lHE ENCLOSURE, REFER TO DRAI'.1NG "POO,".

• <2>~<S>

SHO\\lOl FOR MODELS I'.1lH lHE KVM RECEIVER INSTALLED

MODEL 2653: NEMA 4X FLAT PANEL INTEGRATED IS" MONITOR MODEL 2656: NEMA 4X FLAT PANEL INTEGRATED 19" MONITOR MODEL 2656: NEMA 4X FLAT PANEL INTEGRATED 22" MONITOR MODEL 2623: DIlnSiON 2 NON-INCENDIVE FLAT PANEL INTEGRATED IS" MONITOR MODEL 2626: DIVISION 2 NON-INCENDIVE FLAT PANEL INTEGRATED '9" MONITOR MODEL 2626: DIVISION 2 NON-INCENDIVE FLAT PANEL INTEGRATED 22" MONITOR

CD

<2>~<S> SHO\\lOl FOR MODELS I'.1lHOUT lHE KVIM RECEIVER INSTALLED

MODEL 2553KP: NatA 4X FLAT PANEl 15- MONITOR wI KEYPAD MODEL 2S56KP: NEMA 4X FLAT PANEL '9" MONITOR w/ KEYPAD MODEL 2556KP: NEMA 4X FLAT PANEL 22" MONITOR w/ KEYPAD MODEL 2S2:lKP: DIlnSION 2 NON-INCENDIVE FLAT PANEL IS" MONITOR w/ KEYPAD MODEL 2S26KP: DIlnSION 2 NON-INCENDIVE FLAT PANEL 19" MONITOR w/ KEYPAD MODEL 2S26KP: DIlnSION 2 NON-INCENDIVE FLAT PANEL 22" MONITOR w/ KEYPAD

DIMENSIONS ARE IN INCHES

12~~E~~~~!~£· I CONNECTIONS FOR REMOTE

THIS DOCUMENT IS PROPRIETARY TO DAISY DATA, INC. NON-PURGED ENCLOSURES THE USE OF OR REPRODUCllON OF THIS DOCUMENT IS PROHIBITED EXCEPT AS AUTHORIZED BY I ORAMNG NU"E003 I~A DAISY DATA IN WRITlNG. SPECIFICATIONS ARE ELECTRICAL INPUT DRAWING SUB,JECT TO CHANGE WITHOUT NOTICE. . .

We Thrive ill !he Harshe.' Envrronmenls VOIce: (717) 932-9999 FAX: (717) 932-8000 or VlSlt U. At www.dai.yda1a.com SHEET 1 OF 1

Page 35: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

@ TABLE 1

MODEL lDIGlH

8573 25' .... !lO' .... 100'

."7 1!lO' .... 200' .... "",,'

.570 300'

•• 71 "",,'

.572 400'

9574 500'

NOTES:

TO ruSTOMER INPUT CORD GRIP

:c!§!

~d~n

FACTORY WIRED TO DAISY DATA

EQUIPMENT

'1' THE 120 VAC POWER INPUT CONNECllON IS LOCATED ON THE INSIDE REAR WALL \"II IN THE UPPER LEFT CORNER FOR ALL MODELS SHOWN. USE THE CONNECllON

PIN-OUT OF THE 6 POSIllON TERMINAL STRIP.

THE SlNGAL BOARD COMPUTER IS LOCATED ON THE CENTER OF THE INSIDE REAR WALL FOR ALL MODELS SHOWN. THE 10/1OD BASET NETWORK IS STANDARD FOR ALL PC's. THE RJ45 - RJ45 CATS CABLE CAN BE UP TO 328 FEET LONG.

SEE TABLE I FOR THE DAISY DATA CATS INPUT CABLE MODEL NUMBER '" LENGTH.

FOR CABLE '" CONDUIT ENTRY INTO THE ENCLOSURE, REFER TO DRAIMNG "POOl".

MODEL 4353: NEMA 4X IS" FLAT PANEL INTEGRATED PC MODEL 4356: NEMA 4X 19" FLAT PANEL INTEGRATED PC MODEL 4358: NEMA 4X 22" FLAT PANEL INTEGRATED PC MODEL 4323: DIVISION 2 NON-INCENDIIIE IS" FLAT PANEL INTEGRATED PC MODEL 4326: DIVISION 2 NON-INCENDIIIE 19" FLAT PANEL INTEGRATED PC MODEL 4328: DIVISION 2 NON-INCENDIIIE 22" FLAT PANEL INTEGRATED PC

MODEL 4553KP: NEMA 4X IS" FLAT PANEL PC w/ KEYPAD MODEL 4556KP: NEMA 4X 19" FLAT PANEL PC w/ KEYPAD MODEL 4558KP: NEMA 4X 22" FLAT PANEL PC w/ KEYPAD MODEL 4523KP: DIVISION 2 NON-INCENDIIIE NDN-INTEGRATED IS" FLAT PANEL PC w/ KEYPAD MODEL 4526KP: DIVISION 2 NON-INCENDIIIE NDN-INTEGRATED 19" FLAT PANEL PC w/ KEYPAD MODEL 4528KP: DIVISION 2 NON-INCENDIIIE NON-INTEGRATED 22" FLAT PANEL PC w/ KEYPAD

DIMENSIONS ARE IN INCHES Daisy Data, Inc. I CONNECTIONS FOR LCD-PC

THIS DOCUMENT IS PROPRIETARY TO DAISY DATA" INC. NON-PURGED ENCLOSURES THE USE OF OR REPRODUCTION OF THIS DOCUMENT 2850 Lewisberry Road, York Haven, PA 17370 IS PROHIBITED EXCEPT AS AUTHORIZED BY I DRAWING NUMBER I~A DAISY DATA IN WRITING. SPECIFICATIONS ARE ELECTRICAL INPUT DRAWING EOO6 SUB.JECT TO CHANGE WITHOUT NOTICE.

. . We Thrive m the Harshest Envrronments Vo,ce: (717) 932-9999 FAX: (717) 932-8000 orV,s,t Us Atwww.daisydata.com SHEET 1 OF 1

Page 36: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

.... ,~ ~ (08NQWd_'''_ 'I!!- 5

11" ..,..."

.... ,~

~5°~ ""'T

NOTEs.

CD Wi 1HE IIEIIIEIICML'I" SMa) ABA'I" tHAT CIII1IIIU 'Hi: aJI'IUIBI CIINTM:'II.

CD 1ts"H~ Cl'lM1N WLTAIE CI" 1H! Y/Z-I'UIZ III.NW IDMIL tHE WLTMES ME 11& ~ DD \lAC.

C5J Itis" Q.25 ... 210 WIlT FIJIE,

(!) ~ .. \lAC N'UT. 'ME VlLTMIE 1'IPE • E.IC'IIII CIiII 1HE ZPA IDMIL 1111 SI'PUEII PGiDmEiacm: 1IIi: RELAY II w.lAtE 1HE LID. '!HE CIIINIIEC'IIIIi • YMIE AT 111£ FIICRIt'I" ... ......., MOT • .nHD W'II 1HE CUIIaIER catfI'ACI'I,

1+-'''''10 .. -'"'''' SwItoh

...... """ .... IlfMS ARE HID stQMIII m Fe! E

• AII'IMI! '-'0 CWF! MI'! CPtfM"'"

yoof! 8'21 1- ------------------TA-i------------------------------~ ~A~

• I IEAY,. , C 'I!!-

:~~~::::~~~:L::::::::::::::~~~::~::::::~--J j["'''' ~ +24V DC POWER A

WSUPPLY

", .... pmrH!!VWI At:

IN'UT AC POWER

lB:1

F E

NEU'TR"'I.!l!l D c • •

....

""', ...... .. NOr

.. " .. '"

"''"'"'''' ..

e, .' '"

lID ' L ______________________________ ~

Page 37: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

TAII.E 1 ..... """" .... ... - '" ... , ... .., '''' - ... ... ..,

..,. ... 1071 .... .... ... "",. ""

NOTES:

<D ~nk20~~~W:~C:~~~~U:~~WAU. @

PIN-OUT or THE 8 POSITION TERNIMAL STRIP.

11£ 1M! REMOTE RECEIVER IS LOCATED ON 11£ CENTER OF' 11£ INSIJE REAR WALL FCR AU. MODELS SI-IOVtI. 11£ 1M! RECEIVER IIPJT DATA CABLE IS A R.I46 CA'M CABlE. 1HS CABLE CAN BE .... 10 400 FEET UN1 "IE THE PlN_QIII FBCIf THE SIPPI ED KW H,,"IIN EQR lH§ Gee E D£ KW RfW'£R NAX II' D.WAGFJ) F THE "hAlT 1$ HQI m,!?'fIl MODELS fIfTH THE ~o KW INSTALLED- OPllCJt REQUIRE A aJSTOMER SUPPLED HD1!S PI..OO SVGA \/IDEO CAII.E CCNlEClED 10 THE UNIT. 11£ HD1!S \/lEO INPUT cotf£C1ION IS LOCATED ON 1l£ REAR OF' 1l£ FRONT DOOR FOR ALL MODEl.S SHQIMt.

SEE TAII.E 1 FCR THE DAISY DATA KW CA1l5 IIPJT CAEI.E MOOEL NUMBER • LENGTH. 11£ Y-PJRGE AL.ARM BOARD (1033-000002-0.:5) IS LOCAlED ON THE RIGHT SIDE FOR AU. WODELS SH01lI. CXlNTACTt " .t: 12 CAN BE II1RED NORMALLY OPEN OR NORMAL a.osm. A SIX CONIIJUC'ItIR CABLE IS REQUIRED.

FOR CABLE a: cotIlUIT ENTRY INlO THE ENa.osuRE" REFER 10 DRAWNG -pc)Q2-,

11£ ~ INPUT FlT11NG IS A 1/4- NPT FEMALE. THE Aft SOURCE MUST BE a.EAN DRY INSTRUMENT GRADE AR eAPABLE OF SlJIPI..'tIIG J!I TO 1!1O sa:H FROM 20 10 100 PSI.

• SHOM! ~ MODELS YltTHOUT THE leW RECEMR tlSTALLED

MODEL. 2813: DM9(J11 1 V-PURGE FLAT PANEL 10· INTEGRATED MONITOR MODEL 2818: DMSION 1 Y-PURGE FlAT PANEL , .... 1EGRAlED MONITOR MODEl.. 2811k DMSION 1 Y-PURGE FLAT PANEl. 22- IN1EGRATED MONITCR

YPA

Page 38: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

"""""' ... 10 DAIS'I' DATA ..........

G TABLE 1 ..... ......

"" '" .. ., ... ,,.. ""

,., ... "'" ... .., ..,. ... ""

.., .." ... ..,. ...

NOlES:

(]) ~~20~~=Jt~~~LOCA~~USE1HE~~~~WIU. PlN-CIJT CF 1l£ I POST1ON TERMINAL STRIP.

If\\. 1HE SINGAI.. BOARD CCMPUlER IS LOCAlED 01 lHE CENTER OF 11£ INSIDE REAR WALL v.1 FOR ALL IIIOOEI.S SHOIM\I. lHE 101100 BASEr NETWORK IS STANDARD FOR

AU. PC's. 11£ R.Me - RJ46 CA18 CABLE eNol IE UP 10 _ FEET LONG.

SEE TABLE 1 FOR 1HE DAISY DATA CATS IIfIUT CABLE MODEl.. NUMBER II LENGlH. 11£ Y-PURGE ALARN BOARD (m3-OOOOCI2-CD) IS LOCAlED art lHE RIGHT SlIE FOR

~lICIELSa.o::,.mr'9~~N~~~ =:"~AU.y CI'EN OR FOR CABlE II: CONDUIT ENTRY INTO 11£ ENa..OSI.R, REFER TO DRA'MNG "1"002". 11£ AR INPUT FIT1IfG IS A 1/4- NPT FEMALE. lHE AR SOURCE IIJST IE a.EAN DRY INSlRUNENT GRADE AR CAPABLE OF' SUPPLYING 35 TO 150 SCFH AT 20 - 100 PSI.

MODEL ~'J: DMSIClN 1 V-PURGE 1$" FLAT PANEL .nEGRA-lED PC MODEL ~'I: DMSIQN 1 V-PURGE 1r FLAT PANEL lN1EGRAlED PC MODEL ~llt DMSIClN 1 V-PURGE :zr FlAT PN£L INTEGRATED PC

MODEL. 461JKP: DMSICN 1 V-PURGE 115" FLAT PANEl.. MODEL 4&18ICP: DMSICN 1 V-PURGE 1V FLAT PANEL MODEL 4&111CP: DMSICN 1 V-PURGE 22" FLAT PAtEL.

WAlL

YPA

QJS'RJMER SUPUED ALARM CABLE - II ~

Page 39: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

(j)

RII'BMB 81- ED ""." H

CA15 NA1WDRK

N'UT DATA. I PAR

N'UT DATA. I PAR

FRONT PANE! EXTERNAL EQUIPMENT (IN CAST AWMINUM BOX).

ElP. PROCF SOlENOI)

+24V

~ ." 0

~ I1DO-~

... --------- lCPl r--- / 1.5. BARRIERS I.S. POIER .. --------- BOARD I.S. POIER 6Y, BY, I INlIER wrIT. 6/16V

~pr" ... -------h ... -------

I

RACK pANEl

INlERNAL EQUIPMENT

+~ I noo-~ DJ), PIN: I

I .,,4-000008 I D.D. Phi:

I

! 1.5.

LO POIIER SAPe DMB "Al:"=~- BOARD

~ I BOARD

;J:;~- r-

PURGE STAlUS LED

+~ ~

DJ), PIN: I~I D.D.P,M'.:EIN-ODDDDI I 1).1). PIN: 1D88-ODDDDI-ot ~ I01'I-DDDDDD EIID3-ODDD1Q, aKD-DDDD'lI .. " .. ,---------...1 DJL Phi: BARRIER" 1).1). pIN: nDD-0DD704

~ 0.0.':':" : n .. noo-

~U:al'~ , .....

SSB - ------....... 7-<11 BOARD +24V -p~~r ... CA15NE1WDRK - ------... --------- OAT • ... --------- DATA II ---- -.,

D.D. PIN: I053-OOODDD I

~.:-..: I I I I I

1).1). PIN: I o.o.PJIt ~ 12DY AC PCNER H1I1I-01IU1 11 111

I CA'" NE1W1RC CA1&NElWDRIC SIB BOARD

~u IIDD-OOII2O ~ ----~!~

OAT. ----~!~ I).I).Vp ,

HOO-,,"~ DJ), PIN: IDI2-ODDDDD

.. mEL 2INI DMSIDN 1 X-PI.RGE FLAT PANEL IN1EGRAlED 1e- .. m«nR

.. mEL 2tIIII; DMSIDN 1 IC-PURGE FLAT PANEL IN1EGRAlED 1r .. m«nR

.. mEL .. DMSION 1 IC-PUROE FLAT PANEL IH1EGRAlED 22" MOfrI'Iat

.. mEL 4313:; DMSIDN 1 IC-PURGE 15" FLAT PANEL IN1EGRAlED PC

.. mEL 4aI; DMSION 1 IC-PUROE 1r FLAT PANEL IH1EGRAlED PC

.. mEL 4318; DMSION 1 X-PURGE 22" FLAT PANEl IN1ECRAlED PC

.. mEL 2III3ICP: II\IISION 1 x-Pt.RGE FLAT PANEl 15" MOfrI'Iat w/ KEYPAD

..mEL 2IIIIIICP: II\IISION 1 x-Pt.RGE FLAT PANEl 1r MOfrI'Iat -Z KEYPAD

.. mEL 2l!IaCPl DI\IISION 1 lC-PI.RGE FLAT PANEl 22" MDNITDR _/ ICE'l'PAD

.. mEL 4M3ICP: II\IISION 1 lC-PI.RGE 15" FLAT PANEl PC _/ KEYPAD

.. mEL 4MIICPl II\IISION 1 X-PlRCE Ir FLAT PANEl PC _/ICE'IPAD

.. mEL 4IIII!CP; DI\IISION 1 x-PURGE 22" FLAT PANEl PC w/ICE'l'PAD

NOlES, (]) =.,:u:":"'~T ENTRY IN10 'D£ ENC1.CIIlIE, REFER 10

(2) REFER 10 NIIYIJIJAL QRQIIT BOARD PAGES FOR DETALED INFOIIIAlION.

DIM':N.ION. "'I'I1II': IN INCH':. DalS:X Data Inc I STAND ALONE X PURGED I. ~~ EJICUI'T _ AUlH_ ~ 28,OLewilr Road, yadtHavca,.PAl7370 :::~II~1J.-=":A-TA,mlNC. . ,. ELECTRICAL BLOCK DIAGRAM iOr~TA-r: =.=&~.m.n ECTRICAL BLOCK DIAGRAM DRAWING! ~6 rA

WeThrivem1helllnhestFm1romnen1B Voice: (117) 932-9999 F.AX:(717)932-8000 orVI81tUsAtwww.daisydata..com. SHEET 1 CF 1

Page 40: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

OPTION #1

AC POWER INPUT to BOTH PURGE CONTROL

INTERNAL EQIPMENT

AC POWER INPUT to INTERNAL

EQUIPMENT ONLY

INNER EDGE OF BOARD

OUTER EDGE OF BOARD

1051-000000 POWER INTERFACE BOARD

DIMENSIONS ARE IN INCHES

lHlS DOCUMENT IS PROPRETARY TO DAISY DATA. INC-THE USE OF OR REPROOUClION OF THIS DOCUMENT IS PROHIBITED EKCEPT AS AUTHORIZED BY

AC POWER INPUT to PURGE CONTROL from U.P.S.

NOTES:

CD THE CUSTOMER SUPPUED 115/230 VAt. THIS INPUT UNE WILL SUPPLY THE INlERNAL EQUIPMENT 'MlH At POWER 'MiEN THE ENCLOSURE IS SAFELY PURGED. IT CAN ALSO SUPPLY VOLTAGE TO RUN THE PURGE SYSlEM IF 51 IS CLOSED (TO OUlER EDGE OF BOARD). SEE OPllON ".

ALARM RELAY;

~~~~~!iii~ INTRINSIC SAFETY BARRIERS MOUNTING RAIL GROUND. ::. 'MLL BE MADE BY DAISY DATA. THE OTHER TWO MUST

OF TRUE EARTH GROUND.

THE CONNECTION POINT FOR AN EXTERNAL ALARM. THE CURRENT RAllNG FOR THIS IS 10 AMPS. THE -Ne· CONTACT IS OPEN 'MiEN THE PURGE CYCLE IS COMPLETE OR IN BYPASS MOOE. THE -NO· CONTACT IS CLOSED WHEN THE PURGE CYa.E IS COMPLElE OR IN BYPASS MODE.

AUXIliARY AC POER INpUT' THE C(JIINECllON POINT FOR THE CUSTOMER SUPPUED 11~/230 VAC. THIS INPUT 'MLL PROVIDE VOLTAGE TO RUN THE PURGE SYSTEM WHEN 51 IS OPEN (TO THE INNER EDGE OF THE BOARD). THIS MAY BE CONNEClED TO AN UNIN1ERRUPTABLE POWER SUPPLY IN A SAFE AREA. THIS WILL ENSURE THE PURGE IS NOT LOST DURING SHORT POWER FAlWRES. SEE OPllON f2. TO INSERT YolRES INTO THE CONNECTORS SUPPUED FOR MAIN 1£ POWER. BARRIER GROUNDS. ALARM RELAY'" AUlCIUARY 1£ POWER. STRIP THE YolRE INSULATION OFF 1/4" '" TIN. UNSCREW THE TERMINAL UNTIL THE YolRE YolLL AT IN ... SCREW TILL THE YolRE IS SECURE.

lil.:. S1 SHOULD BE OPEN (TO THE INNER EDGE OF THE BOARD) YlHEN USING THE AUXlUARY POWER CONNECllON. 51 SHOULD BE a.OSED (TO THE OUTER EDGE OF THE BOARD) WHEN USING THE MAIN AC POWER CONNECllON FOR BOTH THE PURGE CONlROL a: INTERNAL AC POWER.

S2:. THIS IS THE INPUT VOLTAGE SELECTOR SYolTCH FOR BOTH THE MAIN'" AUXIUARY INPUTS. IT IS FOR 115 OR 230 VAC.

fli. THIS IS A O.SA • 115V OR A o.25A 0 2JOV FUSE. F1 CONlROLS THE I.S. POWER TO THE PURGE CONlROL BOARD.

f2:. THIS IS A lOA 0 115V OR A 5A 0 230V FUSE. F2 CONTROLS THE 1£ POWER TO THE INTERNAL EQUIPMENT.

12~~~!?~!~~!1}£· I POWER INTERFACE BOARD ITEM LOCATION I DRAWING NUMBO 17 rA DAISY DATA IN WRIl1NG. SPECIFlCA110NS ARE ITEM LOCATION DIAGRAM DRAWING SUB,JECT TO CHANGE WITHOUT NOTICE. . .

We Thrive m the Harshest EnvtrOnmen1s VOice: (717) 932-9999 FAX: (717) 932-8000 or VlSlt Us At www.daisydata.com Sl-lEET 1 OF 1

Page 41: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

(@) 0 Green/N0t2

Blue/NetJ ( ® ) Red/NeI1 J5

(@)) J6 CDJA

J7 l~tEntEntEntEntEntEntEntEntEntEn~~1 (2) !!'.'.'.'.';:;""'.'.'.'!! 00 00

1053-000000 SIGNAL SWITCHING BOARD

NOTES:

CD

® ® <L>

.JAi. JA IS CONNECTED TO J13 ONE TO ONE. SEE lHE SSB-SIB CONNECTION TABLE FOR A MORE DETAILED PIN-OUT. J13 IS CONNECTED TO JA ON lHE INTERNAL SIGNAL INTERFACE BOARD lHOUGH lHE PAC-SEAL.

&. JB IS CONNECTED TO J12 ONE TO ONE. SEE lHE SSB-SIB CONNECTION TABLE FOR A MORE DETAILED PIN-OUT. J12 IS CONNECTED TO JB ON lHE INTERNAL SIGNAL INTERFACE BOARD lHOUGH lHE PAC-SEAL.

~ JC IS CONNECTED TO J13 ONE TO ONE. SEE lHE SSB-SIB CONNECTION TABLE FOR A MORE DETAILED PIN-OUT. J3 IS CONNECTED TO JC ON lHE INTERNAL SIGNAL INTERFACE BOARD lHOUGH lHE PAC-SEAL.

TO INSERT I'I1RES INTO lHE CONNECTORS SUPPUED AT JA, JB & JC, STRIP lHE I'I1RE INSULATION OFF 1/4" & TIN. UNSCREW lHE TERMINAL UNTIL lHE I'I1RE I'I1LL FIT IN & SCREW TILL lHE I'I1RE IS SECURE.

,[£. SHORT WHEN NET3 (J5) IS USED FOR ARCNET.

J15 & J16; SHORT BOlH WHEN NET1 (J6) & NET2 (J4) ARE USED FOR lHINNET.

J1 & J2· FOR ARCNET NETWORK LOOPBACK. CONSULT FACTORY FOR MORE INFOMATION.

DIMENSIONS ARE IN INCHES Daisy Data, Inc. SIGNAL SWITCHING THIS DOCUMENT IS PROPRIETARY TO DAISY DATA. INC. BOARD ITEM LOCATION THE USE OF OR REPRODUCTION OF THIS DOCUMENT

2850 Lewisberry Road, York Haven, PA 17370 IS PROHIBITED EXCEPT AS AUTHORIZED BY I DRAIIlNG NUMBEO 18 I"OA DAISY DATA IN WRITING. SPECIFICATIONS ARE ITEM LOCATION DIAGRAM DRAWING SUBJECT TO CHANGE WITHOUT NOTICE. . . We Thrive m the Harshest EnVIronments VOlce: (717) 932-9999 FAX: (717) 932-8000 or VlSlt Us At www.datsydata.com SHEET 1 OF 1

Page 42: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

0 Jl J2 ~

0 •

@

J3 JC @

0 J8

J/ NOTES:

<D ..!A;.

(i) JA IS CONNEClED TO J13 ONE TO ONE. SEE lHE SSB-SIB CONNECTION TABLE FOR A MORE DETAILED PIN-OUT. J13 IS CONNEClED TO JA ON lHE SIGNAL SWITCHING

J12 J9 BOARD lHOUGH lHE PAC-SEAL

(i) .JIl;.

0 JB IS CONNEClED TO J12 ONE TO ONE. SEE lHE SSB-SIB CONNECTION TABLE FOR A MORE DETAILED PIN-OUT. J12 IS CONNEClED TO JB ON lHE SIGNAL SWITCHING

JB BOARD lHOUGH lHE PAC-SEAL

0 Jl0 0 JI1 (i) @ ,!Q;.

JC IS CONNEClED TO J13 ONE TO ONE. SEE lHE SSB-SIB CONNECTION TABLE FOR

<D ~ A MORE DETAILED PIN-OUT. J3 IS CONNEClED TO JC ON lHE SIGNAL SWITCHING BOARD lHOUGH lHE PAC-SEAL

J13 @) TO INSERT WIRES INTO lHE CONNECTORS SUPPLIED AT JA. JB & JC. J14 SllRlP lHE WIRE INSULATION OFF 1/4" & TIN. UNSCREW lHE lERMINAL

~ <D UNTIL THE WIRE WILL FIT IN & SCREW TILL lHE WIRE IS SECURE.

JA

o o o

1052-000000 INTERNAL SIGNAL INTERFACE BOARD

DIMENSIONS ARE IN INCHES Daisy Data, Inc. INTERNAL SIGNAL INTERFACE THIS DOCUMENT IS PROPRIETARY TO DAISY DATA. INC. BOARD ITEM LOCATION THE USE OF OR REPRODUCTION OF THIS DOCUMENT IS PROHIBITED EXCEPT AS AUTHORIZED BY 2850 Lewisberry Road. York Haven. PA 17370 I DRA'MNG NUMBEO 19 I~"~ DAISY DATA IN WRITING. SPECIFICATlONS ARE ITEM LOCATION DIAGRAM DRAWING SUB.JECT TO CHANGE WITHOUT NOTICE. . .

We Thrive ill the Harshest Envrronments VOIce: (717) 932-9999 FAX: (717) 932-8000 or VISIt Us At www.daisydata.com SHEET 1 OF 1

Page 43: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

o

o

<D ~ S1 S2

[1][1] BYPASS SHORT PURGE PURGE

o @

i~~l:~URE SIZE

SENSOR lYPE SECONDARY ENCLOSURE SIZE

o 1071-000000

DIP SWITCH MOUNTING BOARD

DIMENSIONS ARE IN INCHES

lHlS DOCUMENT IS PROPRIETARY TO DAISY DATA. INC. lHE USE OF OR REPRODUCTION OF lHlS DOCUMENT IS PROHIBITED EXCEPT AS AUTHORIZED BY DAISY DATA IN WRITING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

NOTES:

<D BYPASS PURGE' ]HIS TEST MUST BE PONE IN A SAFE ENVIRONMENT! BYPASS pURGE IS FOR TEST ONLY! THE PURGE CONTROL SYSTEM IS COMPLETELY BYPASSED & THE ISOLATION RELAYS CLOSE IMMEDIATELY. APPLYING POWER & SIGNALS TO ANY CONNECTED INTERNAL ELECTRONICS. THE PURGE STATUS LED ON THE FRONT PANEL WILL BE ILLUMINATED FLASHING GREEN. NO PURGE AIR IS REQUIRED. REMOVIE MAIN AC POWER. PRESS & HOLD THE BYPASS PURGE SWITCH & APPLY MAIN POWER IN TO THE XPI BOARD (SEE NOTES 1 & 4 ON DRAWING "E017"). THEN RELEASE THE SWITCH WITHIN 30 SECONDS. NOW THE UNIT IS IN BYPASS PURGE. ]HE UNITs INTERNAL ENViRONMENT WILL NOT BE SAFE UNLESS A NORMAL pURGE CYCLE IS PONE

SHORT pURGE SWITCH: THIS TEST MUST BE DONE IN A SAFE ENVIRONMENT! SHORT PURGE IS FOR TEST ONLY! THE PURGE CONTROL SYSTEM WILL SET THE PURGE TIME TO 30 SECONDS REGARDLESS OF THE SETIING ON THE ENCLOSURE SIZE SELECT DIP SWITCHES. THE PURGE WILL THEN CONTINUE AS NORMAL. THE PURGE STATUS LED WILL BE ILLUMINATED GREEN. PURGE AIR IS REQUIRED. REMOVIE MAIN AC POWER IN. PRESS & HOLD THE SHORT PURGE SWITCH & APPLY MAIN POWER IN TO THE XPI BOARD (SEE NOTES 1 & 4 ON DRAWING "E017"). THEN RELEASE THE SWITCH WITHIN 30 SECOND . CLOSE THE SWITCH COVIER & THE ENCLOSURE DOOR. APPLY AIR TO THE PURGE SYSTEM. THE UNIT IS NOW OPERATING NORMALLY. THE UNIT'S INTERNAL ENVIRONMENT WILL NOT BE SAFE UNLESS A NORMAL PURGE CYCLE IS DONE.

ENCLOSURE SIZE PIP SWITCHES' THE DIP SWITCHES CONTROL THE TIMING OF THE NORMAL PURGE CYCLE. FOR BOTH THE 15" & 18" DISPLAY MODELS THE PURGE TIME WILL BE 8 MINUTES. THE FOLLOW ARE THE CORRECT SETTINGS OF THE SWITCHES. 1: OFF 2: OFF 3: ON 4: OFF 5: ON 6: ON 7: ON 8: ON

Daisy Data, Inc. DIP SWITCH MOUNTING (DMB) BOARD ITEM LOCATION

2850 Lewisberry Road, York Haven. PA 17370

ITEM LOCATION DIAGRAM DRAWING I DRAI't1NG NUt,48

E020 IREB

. . We Thrive III the Harshest Envrronments VOice: (717) 932-9999 FAX: (717) 932-8000 or VISit Us At www.dwsydata.com SHEET 1 OF 1

Page 44: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

o@ @

1068-000001-01 PURGE CONTROL BOARD

DIMENSIONS ARE IN INCHES

THIS DOCUMENT IS PROPRIETARY TO DAISY DATA. INC. THE USE OF OR REPRODUCTION OF THIS DOCUMENT IS PROHIBITED EXCEPT AS AUTHORIZED BY DAISY DATA IN WRITING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

0

~ro:s

NOTES: G)

(Z)

Q)

@

EPROM: THIS IS THE FACTORY SUPPLIED EPROM WITH THE SOFTWARE FOR THE PURGE SYSTEM.

JUMpER SETTINGS' ALL JUMpERS ARE SET AT THE FACTORY! PO NOT CHANGE!

FLOW & PRESSURE ADJUSTMENTS: ALL POTENTIOMETERS ARE SET AT THE FACTORYI PO NOT CHANGEI

FLOW SENSOR: THIS IS THE SENSOR THAT MEASURES THE AIR FLOW INTO THE ENCLOSURE. THE RED HOSE IS CONNECTED TO PORT "A".

PRESSURE SENSOR: [J- @ THIS IS THE SENSOR THAT MEASURES THE AIR PRESSURE INSIDE OF THE ENCLOSURE. THE BLUE HOSE IS CONNECTED TO PORT "A".

0

Daisy Data, Inc. PURGE CONTROL BOARD ITEM LOCATION

2850 Lewisberry Road, York Haven, PA 17370 I DRA'MNG NUMB

E021 IRE~ ITEM LOCATION DIAGRAM DRAWING We Thrive in the Harshest Environments Voice: (717) 932-9999 FAX: (717) 932-8000 or Visit Us At www.daisydata.com SHEET 1 OF 1

Page 45: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

nOD-OOlJ47-ot

11£ IMI REMOTE RECEMR IS LOCATED ON lHE CENTER (F 11£ INaE REM WALL FOR AU. MOOELS !!HOM. lHE ICW RECEI\U IFUT DATA CAlLE IS A RJ40 CATD CABLE. lHlS CAEIl.E CAN BE l.P 10 400 FEET LONG. liE n£ f"HIIT m'N n£ • .,.. ED KW HAMIN EPI DIS 'WI E

n£ KW 11m'" NAY BE' D'N''fQ F n£ fill-PIT IS NQI m, CWIl

SEE TABLE 1 FOR 11£ DAISY DATA CATS INPUT CAlLE IIIQDEl NUMBER. LENGTH.

FOR CABLE .til cotaIT ENTRY INTO 11£ ENQ.OSURE, REFER 10 IRA.Me "POOT.

11£ AIR IFUT FlTTWG IS A 1/4- NPT FEYALL lHE oWl SOURCE MUST BE a.EAN

IIIQDEl 2IIIJ; DMSlON 1 IIIQDEl 2IIH: DMSlON 1 IIIQDEl 2188:: DMSlON 1

DRY INS1RtAIENT GRADE oWl CAPABLE (F SUPPI..'l'lNG 40 10 JOO SCFH AT 3D 10 10 PSI.

MODELS .lH 11£ "NO Ie ..... 1fSTALLED" CPIION REQURE SVIM \'IDEO 10 CXlNI£CT 10 11£ lHREE BNC'S (RED. GREEN II a.uE) ON lHE S!II BONI).

(J) 11:111 0 ---I051-'8CloOOO

o

'-E:NC~OSUI~E WALL

FLAT PANEL 15" IlDlITOR _/ICE"IPAD FLAT PANEL 1V IlDlITOR _/ICE"IPAD FLAT PANEL 22" MctI'RlA _/KEYPAD

-Q&~x'!?~~.z.!~£· ELECTRICAL INPUT DRAWING

I CONNECTIONS FOR REMOTE X-PURGED ENCLOSURES 1-' EU22 rio.

We Thrive in the Harshest Enviromnent!I VOIOO: (717) 932-9999 FAX: (717) 932-8000 or Visit Us At www.daisydata.com stEEl 1 OF'

G.l TABlE 1 ..... ...... "" rtf - or - ,,.. ... 'w - "'" - "'" "'" Df

"" -"" "'" ..,. "'"

(J)

CUS'RlMER SUPPLED AI..ARM CABLE - ;, CCfIllICTCR

Page 46: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

IICIlEL 4.18J:: DMIION 1 15- FLAT PANEL NlEGRAlED PC IICIlEL 4.1M: DMIION 1 lC-PLRGE , .. FLAT PANEL NlEGRAlED PC MODEL 4JI&: DlWiION 1 X-PURGE 22" FLAT PANEL IN1ECRAlED PC

NOlES:

CD :i1:U~CClN~~1l£~~~=V~= =~~~ ~J.UM BOX BOARD 0051-000000). 11£ ALARM RELAY CONNECTION IS ALSO ON 1t£ )(pi BOARD. A lHREE CClNDUCTClR CABlE IS REQUIRED.

1HE DATA SIGNAL INPIIlS CCIhtEClIONS ARE ON THE SSB ~ccm). 1t£ CATS NE1WORIC CAN PLUG INlO CABLE nDO-OO13407-o1 wtlat IS 'M1H 1HE UNT.

1HE SINGAL BOARD COMPUTER IS LOCATED ON 11£ CENTER OF 11£ INSIDE REAR WALl. FOR AU. MOOELS SHQIMII. 11£ 101100 BASET NE1WORIC IS STNCIARD FOR AU. PC'$. 1l£ RJ45 - RJ45 CAD CABLE CAN BE IF 10 J28 FEET LJ:ItC.

SEE TABLE 1 FOR 1HE DAISY DATA CA1S IN"UT CABlE MODEL IU&R • LENGlH.

FOR CABLE • COfOJIT ENTRY INN 11£ ENCI.OSURE. REFER 10 DRAWING ~.

1HE Aft INPUT FlTlI«J IS A 11.- NPT FEMALE. 11£ AIR SOURCE MUST BE a.EAN DRY IG1Rt.IENT GRADE All CAPABLE OF 5U'PLYING 40 10 JOO sa=H AT 3D 10 10 PSI.

'-I'NCILOSIJRE WALL

IICIlEL 4Ml:: DMIION 1 X-PURGE 15- FLAT PANEL PC IICIlEL <eH: DMaON 1 X-PUlGE , .. fLAT PANEL PC IIODEL «IH: DMSION 1 lC-PLRGE 22" FLAT PN£L PC

(J) 11:111 0 ---

DIMENSIONS ARE IN INCI-oIIi':. D· D t I I CONNECTIONS FOR LCD PC ='~.~1l-"=~ 23S~R.oud.!~l..PA~390· X-PURGED ENCLOSURES fo'v~~=*ci~Tn~ ELECTRICAL INPUT DRAWING 1- rl

We Thrive m the Harshest Enviromnents Vou:e: (717) 932-9999 FAX: (717) 932-8000 01" Visit Us At www.daisydata.com SI£ET 1 OF'

® TABLE 1 ..... ...... .... .. ... of - ...

"" ... .. .., ... "'" ... Df

"" "'" .... at ..,. "'"

(J)

CUSlOMER SUPPLED ALARM CABlE - ~ CClNDUCTCR

Page 47: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

DIMENSIONS ARE

1301-000026 28 KEY KEYPAD

STANDARD LEGEND CD o 0

B88GGGG 80000w8 8 GGGBBB 000008CD

o 0

NOTE: CD KEyPAD LAYOUT:

THIS IS THE STANDARD LAYOUT OF THE KEyPAD. FOR SPECIAL LAYOUTS, PLEASE CONTACT DAISY DATA.

IN INCHES

o

o

28 Daisy Data, Inc. 'THIS DOCUMENT IS PROPRIETARY TO DAISY DATA, INC. KEYPAD THE USE OF OR REPRODUCTION OF THIS DOCUMENT

KEY LAYOUT

IS PROHIBITED EXCEPT AS AUTHORIZED BY 2850 Lewisberry Road, York Haven, PA 17370 I DRAWING NUMB

E086 DAISY DATA IN WRITING. SPECIFICATIONS ARE ITEM LOCATION DIAGRAM DRAWING SUBJECT TO CHANGE WITHOUT NOTICE.

We Thrive in the Harshest Environments Voice: (717) 932-9999 FAX: (717) 932-8000 or Visit Us At www.daisydata.com SHEET 1 OF 1

I~e~

Page 48: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

1301-000029 KEYPAD FOR THE

LCD ON SCREEN DISPLAY

8 8 @B DIMENSIONS ARE IN INCHES

THIS DDCUMENT IS PROPRIETARY TO DAISY DATA, INC. THE USE OF OR REPRODUCTION OF THIS DOCUMENT IS PROHIBITED EXCEPT AS AUTHORIZED BY DAISY DATA IN WRITING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

NOTES ON THE KEY FUNCTIONS: ON SCREEN DISPLAY PURPOSE: CD THE O.S.D. BUnONS CONTROL THE BRIGHTNESS, CONTRAST AND SCREEN ON THE DISPLAY.

GEOMETRY OF THE IMAGE

SELECT: SELECTS AN ITEM FROM THE MENU.

_+": MOVES TO THE RIGHT ITEM IN THE MENU, OR MOVES THE HI-LIGHT BAR RIGHT. THE VALUE OF THE SELECTED ITEM. INCREASES

. " - . --' MOVES TO THE LEFT ITEM IN THE MENU, OR MOVES THE HI-LIGHT BAR LEFT. THE VALUE OF THE SELECTED ITEM DECREASES

Menu OPENS AND CLOSES THE O.S.D. MENU

ON SCREEN DISPLAY Daisy Data, Inc. KEYPAD LAYOUT 2850 Lewisberry Road, York Haven, PA 17370 I DRAWING NUMB

E097 ITEM LOCATION DIAGRAM DRAWING IREA

We Thrive in the Harshest Environments Voice: (717) 932-9999 FAX: (717) 932-8000 or Visit Us At www.daisydata.com SHEET 1 OF 1

Page 49: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

PANEL MOUNT ENCLOSURE

i-------------------------l I I

19.0" 10 Cd,pol I 1280.1024 I POO()'OOOl15-01 1301-000034-01

// ~ ~ I

" OSD I 1100-001848 PART OF VIDEO CARD KIT

~ ? I ~~

" ~ J INVERTER

N

/, P130-000022 " P005-000004 " " VIDEO CARD KIT P050-000238

" N

VGA DE-15 Mating Cable: P070-000038

~ J VIDEO POWER P07()'()()()544 MODEL 2576: NEMA 4X PANELMOUNT FLAT PANEL 19" MONITOR

~ PDB 1100-001333-01 "11-

1047-100050 1/ S&12VDC " II

, ... ~ 110!220 S;C 12VDC ....

"

//

I'" POWERIN I 1100-001569 L

I

I I L ________________________ ~

DIMENSIONS ARE IN INCHES Daisy Data, THIS DOCUMENT IS PROPRIETARY TO DAISY DATA. INC. THE USE OF OR REPRODUCTION OF THIS DOCUMENT

POWER IN -1l01220VAC me -C14 (Male Inlet) Mating Cab1.: EOOO-030000

Inc. PANEL MOUNT 1 9" ENCLOSURE

IS PROHIBITED EXCEPT AS AUTHORIZED BY ELEcTrucAL"BLocltbIA:GAAMDRA WING I DRA~NG NUMBE098 DAISY DATA IN WRITING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

We Thrive in the Harshest Environments Voice: (717) 932-9999 FAX: (717) 932-8000 or Visit Us Atwww.daisydata.com SHEET 1 OF 1

I~~~

Page 50: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

PANEL MOUNT ENCLOSURE

i-------------------------l I I

22" IDg~P DI I 1680.1050 I301-00~34-01 I poOO-Ooo 131

* // I "" OSD I 1O()'002048'()1

~~ ~ ~ I PART OF KIT '" ~ tJ INVERTER

N

P005-000007 V/ PARTOFKIT ~

VIDEO CARD KIT I"" N

P050-0oo262

" N

VGA DE-15 Mating Cable: P07().OO0038

VIDEO POWER P070-000460

~ ~ MODEL 2578: NEMA 4X PANELMOUNT FLAT PANEL 22" MONITOR

I ,

~ PDB 11/ 1100-00\333-01 '"

1047-100050

... ~ 110/220 S;C // POWERIN I 1" // 5&12VDC 12VDC ... ""

" 1100-001569 L

I I L ________________________ ~

DIMENSIONS ARE IN INCHES Daisy Data, THIS DOCUMENT IS PROPRIETARY TO DAISY DATA. INC. THE USE OF OR REPRODUCTION OF THIS DOCUMENT

POWER IN -llOf220VAC IEC - CI4 (Male Inlet) Mating Cable: EOo()'03OOoo

Inc. PANEL MOUNT 22" ENCLOSURE

IS PROHIBITED EXCEPT AS AUTHORIZED BY ELECTIuCALBLOcKDIAoiUl1DRA WING I DRAYI1NG NUMBE099 DAISY DATA IN WRITING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

We Thrive in the Harshest Environments Voice: (717) 932-9999 FAX: (717) 932-8000 or Visit Us Atwww.daisydata.com SHEET 1 OF 1

I""~

Page 51: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

EQUIPMENT ENCLOSURE

r,;;;----------1Il.00R OsD SWITCH :l

1301-000034-01 1 1""I.J1k.T" 1

1640-001615-06

I INVERTER L 19" LCD

1 P005-000004 I POOO-000115-01 OSD

~~ 1

""IIIA1 /

~: C2>

TABLE 1 ...... ....... 1 ~~

1

1

1 , .... 1

P050-000238

OSD 1100-001848

//

1

1

1

1

1

1073 .... .... -.... .... ..,. 0&71

to72

157.

,.. ... ,'" , ... fIf1It .... .... .... ... "'"

~/ CD MCDEL 2M1SI<P: DI't'ISION 1 X-PURGE FlAT PANEl1a- MONTOR wi KEYPAD

NOTES:

CD MODEl. 2586KP HAS KEYPAD DOES NOT INQ.UOE THE KEYBOARD ,. POINTING DE\1CE.

1

~---1

_ P_070-_000~~ ___ P070_-000_5~ -I-==--=l=--==,-

~~

M\ SEE TABLE 1 Fa. THE DAISY DATA CA15 INPUT CABlE "'" MODEl. Nut.lBER a: LENGTH. 19\ FOR CABLE ,. CONDUIT ENTRY INTO THE ENa.o5URE. REFER TO \tU ORA'MNG -P0D7-,

1

1

1

1

1

1

1

1

, ......

11 00-00202 ~

100-000863-02

~~ ICK

1024-000017-01

KVM P070-000559 -

FAN 1640-001435

LED

100-001601

11 00-001701~ ; \ ~ TERMINAL STRIP ~ 1640-001168

11 00-000396-0~ ,

--------l I OJSTOt.IER SUPPUED

STAND ALONE PURGE <-"-~~~---i-~---~~":~~!T CABLE 1640-000864-09 "" 1'1\ FROM LOCAl. lRANSU'TlER

KVM DATA L "'" \lIP MODEL e508AC D.D. PIN, ,~-------------<

POWER SUPPLY P010-000062

, ..... '-------,,,-----' 1100-001347-(11 I

I .... , // ffi 1100-001475f " _ ~100-000831 ___ J

~ ~ ~ 1100-001757/~ ~ ~ ~ POWER SUPPLY //

~~ 1640-001426 ........

1100-002024

'---------=---=---=----'--~

1 I KEYPAD 28 KEY

1301-000026 ENCLOSURE

~ ___________ 1640-001406-~

OIMIliii:NSIONS AFltIliii: IN INCI-lIliii:S Daisl Data Inc I REMOTE DIV. 1 X-PURGED THIS DOCUMENT IS PROPAIETARY 10 DAISY DAT .... INC. ,. 19" ENCLOSURE 11£ USE OF' OR REPRa:IIJC'nON OF' THIS OOCUNEf\lT 'S PIilCHIBlTI!D EXCEPT AS AU'THOftIZE~~ 28:50Lewi9 Road, York Haven, PA 17370 r ~ DAISY DATA IN ""'TINa. SPEal"1CATlONS ECTRICAL BLOCK DIAGRAM DRA WINaI-- "£126 sua.JECT TO CHANGE WITHOUT NOTIC ..

We Thrive m the Harshest Environments VOIce. (717) 932-9999 FAX. (711) 932-8000 or ViSit Us At www.daisydata.com SHEET 1 OF 1

Page 52: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

--

WALL MOUNT

isplay H1 H2 H3 W1 Size

o

15.0" 13.97" 12.35" N/A 17.13"

I_I!IIIIIIIIIIIIJI 19.0" 16.62" 15.00" N/A 19.12"

22.0" 18.00" 16.00" N/A 25.00"

BASIC OVERALL DIMENSIONS

15.0"LCDCUT-QUTPATIERN :

L I 19.0" LCO CUT-OUT PATTERN _________________ --1..- ___________________ _

L ____________ ~~·O"LC~_CUT~~PA~~~ _____________ _

W2 01

15.50" 3.50"

17.50" 4.00"

23.00" 3.76"

WALL MOUNT CUT-OUT DIMENSIONS MODEL 2573: NEMA 4X PANELMOUNT FLAT PANEL 15" MONITOR MODEL 2576: NEMA 4X PANELMOUNT FLAT PANEL 19" MONITOR MODEL 2578: NEMA 4X PANELMOUNT FLAT PANEL 22" MONITOR

O2 0 3 VH VW

N/A N/A 9.16" 12.16" N/A N/A 12.01" 14.93" N/A N/A 11 .815" 18.807"

Q~x12~~~!~,s" MECHANICAL ASSEMBLY DRAWING

We Thrive in the HanhCit EnvironmcntII Voice: (717) 932-9999 FAX: (717) 932-11000 or Visit UI Atwww.dailydlta.com B

Page 53: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

II·: :·11

BASIC OVERALL DIMENSIONS

WALL MOUNT

TABLETOP MOUNT DISPLAY SIZE x Y Z

15.0" 21.00" 15.44" 7.72" 19.0" & 22.0" 27.00" 18.98" 9.49"

L ____________________ ~ _________________ _____'

MODEL 2553: NEMA 4X MODEL 2556: NEMA 4X MODEL 2558: NEMA 4X MODEL 4553: NEMA 4X MODEL 4556: NEMA 4X MODEL 4558: NEMA 4X

DISPLAY H1 H2 H3 SIZE

15.0" 19.75" N/A N/A 19.0" 24.75" N/A N/A 22.0" 24.75" N/A N/A

FLAT PANEL 15" MONITOR FLAT PANEL 19" MONITOR FLAT PANEL 22" MONITOR 15" FLAT PANEL PC 19" FLAT PANEL PC 22" FLAT PANEL PC

W1 W2 D1 D2

19.00" N/A 7.50" N/A 25.00" N/A 7.50" N/A 25.00" N/A 7.50" N/A

DIMENSIONS ARE IN INCHES

I

I -,-~~IJ.~~D~WPLCS.)

I I

L __ ~

D3 VH VW

N/A 9.16" 12.16" N/A 12.01" 14.93" N/A 11.815" 18.807"

12~lR~~.!.!~,~·

1\ • 0) D •

WALL MOUNT HOLE DIMENSIONS

THIS DOCUMENT IS PROPRIETARY TO DAISY OAT .... INC. THE USE OF OR REPRODUCTION OF THIS DOCUMENT IS PROHIBITED EXCEPT AS AUTl-iORIZEC BY DAISY DATA IN _lllNO. SPECIFICATIONS ARE SUB..JECT TO CHANGE Wlll-iOUT NOTICE. MECHANICAL ASSEMBLY DRAWING B

We Thrive in 1IlII Hanib.llIIt Enviromnents VoieI!: (717) 932-9999 FAX: (717) 932-8000 or Visit Us Atwww.daisydata.oom.

Page 54: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

BASIC OVERALL DIMENSIONS

DIII5Y U~T

aJSTOMER TAaLTOP

TABLETOP MOUNT

DIII5Y U~T

DAISY PElESTN..

~~~::~ ~ I ~!roll

~-:.[>,;llJi

WALL MOUNT

DISPLAY SIZE 15.0"

19.0" & 22.0"

x Y

21.00" 18.98" 27.00" 18.98"

Z

9.49" 9.49"

PEDESTAL MOUNT : f------------------~--------------------~ -,-

MODEL 2653: MODEL 2656: MODEL 2658: MODEL 4353: MODEL 4356: MODEL 4358:

DISPLAY H1 SIZE

15.0" 23.25" 19.0" 28.25" 22.0" 28.25"

NEMA 4X FLAT PANEL INTEGRATED 15" MONITOR NEMA 4X FLAT PANEL INTEGRATED 19" MONITOR NEMA 4X FLAT PANEL INTEGRATED 22" MONITOR NEMA 4X 15" FLAT PANEL INTEGRATED PC NEMA 4X 19" FLAT PANEL INTEGRATED PC NEMA 4X 22" FLAT PANEL INTEGRATED PC

H2 H3 W1 W2 D1 D2

N/A 3.50" 19.00" N/A 7.50" 16.50" N/A 3.50" 25.00" N/A 7.50" 16.50" N/A 3.50" 25.00" N/A 7.50" 16.50"

D3

N/A N/A N/A

I I

L--i

1\ • J! D

VH VW

9.16" 12.16" 12.01" 14.93" 11.815" 18.807"

I I

I

• j

: WALL MOUNT IHOLE DIMENSIONS

DIMENSIONS ARE IN INCHES

THIS DOCUMENT 15 P~OP~IETARY TO DAISY DATA, INC. THE USE OF CR REPRODUCTION OF THIS DOCUMENT IS PFiOHIBITED EXCEPT AS AUTl-iOFlIZED BY DAISY DATA IN _ITlNQ. SPECIFICATIONS ARE 5UB..JECT TO CHANCE WITHOUT NonCE.

12~xR~~!~,~· NEMA 4X INTEGRATED

MECHANICAL ASSEMBLY DIAGRAMS

MECHANICAL ASSEMBLY DRAWING B We Thrive in the Harshest Enviromncnts Voice: (717) 932-9999 FAX: (717) 932-8000 or Visit Us Atwww.daisyda1a.com

Page 55: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

BASIC OVERALL DIMENSIONS

DMIT UNIT

aJSTOMER TAaLTOP

TABLETOP MOUNT

DIII5T U~T

DAISY PElESTN..

~~~::~ ~ I ~!roll

~-:.[>,;llJi PEDESTAL MOUNT :

f------------------~--------------------~ I I

WALL MOUNT

DISPLAY SIZE 15.0"

19.0" & 22.0"

x Y

21.00" 18.98" 27.00" 18.98"

-,-

MODEL 2623: MODEL 2626: MODEL 2628:

DIVISION DIVISION DIVISION DIVISION DIVISION DIVISION

2 NON-INCENDIVE 2 NON-INCENDIVE 2 NON-INCENDIVE 2 NON-INCENDIVE 2 NON-INCENDIVE 2 NON-INCENDIVE

FLAT PANEL INTEGRATED 15" MONITOR FLAT PANEL INTEGRATED 19" MONITOR FLAT PANEL INTEGRATED 22" MONITOR 15" FLAT PANEL INTEGRATED PC

L--i

1\ •

D MODEL 4323: MODEL 4326: MODEL 4328:

DISPLAY H1 H2 H3 W1 SIZE

19" FLAT PANEL INTEGRATED PC 22" FLAT PANEL INTEGRATED PC

W2 D1 D2 D3 VH VW

I I

I

Z

9.49" 9.49"

J! j

15.0" 23.25" N/A 3.50" 19.00" N/A 7.50" 16.50" N/A 9.16" 12.16" 19.0" 28.25" N/A 3.50" 25.00" N/A 7.50" 16.50" N/A 12.01" 14.93"

: WALL MOUNT IHOLE DIMENSIONS

22.0" 28.25" N/A 3.50" 25.00" N/A 7.50" 16.50" N/A 11.815" 18.807"

DIMENSIONS ARE IN INCHES

THIS DOCUMENT IS P~OP~IET""T TO DAISY DATA, ItlC. THE USE OF OR REPRODUCTION OF THIS DOCUMENT IS PROHIBITED EXCEPT AS AUTl-iORIZED 8Y OAISY DATA IN _ITlNQ. SPECIFICATIONS ARE 5UB..JECT TO CHANGE WITHOUT NonCE.

12~xR~~!~,~· MECHANICAL ASSEMBLY DRAWING

DIVISION 2 NON-INCENDIVE MECHANICAL ASSEMBLY DIAGRAMS

B We Thrive in the Harshest Environments Voice: (717) 932-9999 FAX: (717) 932-8000 or Visit Us Atwww.daisyda1a.com

Page 56: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

lOR KEY

BASIC OVERALL DIMENSIONS

ENCLDSIJRE ASSElELY

DAISY U~T

MODEL 9113

IIA9iER

BOLT

DAISY PElESTN..

WALL MOUNT

TABLETOP MOUNT

~'~!~'~ , .·r [ 22!03[ DISPLAY

SIZE x Y Z

~llJ 15.0" 21.00" 18.98" 9.49" 19.0" & 22.0" 27.00" 18.98" 9.49"

PEDESTAL MOUNT ~---------------------------~--------------------------------~

: \?41J.0~DB~ WPLCS.)

MODEL 2613: MODEL 2616: MODEL 2618: MODEL 4313: MODEL 4316: MODEL 4318:

DISPLAY Hl SIZE

DIVISION DIVISION DIVISION DIVISION DIVISION DIVISION

H2

15.0" 23.25" 30.50" 19.0" 28.25" 35.50" 22.0" 28.25" 35.50"

Y-PURGE FLAT PANEL INTEGRATED 15" MONITOR Y-PURGE FLAT PANEL INTEGRATED 19" MONITOR Y-PURGE FLAT PANEL INTEGRATED 22" MONITOR Y-PURGE 15" FLAT PANEL INTEGRATED PC Y-PURGE 19" FLAT PANEL INTEGRATED PC Y-PURGE 22" FLAT PANEL INTEGRATED PC

H3 Wl W2 Dl D2 D3

3.50" 19.00" 12.50" 7.50" 16.50" 5.00" 3.50" 25.00" 12.50" 7.50" 16.50" 5.00"

L_-i ·1iHf-r-,

D •

VH VW

9.16" 12.16" 12.01 " 14.93" WALL MOUNT

3.50" 25.00" 12.50" 7.50" 16.50" 5.00" 11.815" 18.807" I HOLE DIMENSIONS

DIMENSIONS ARE IN INCHES

THIS DOCUMENT IS PROPRIETARY TO DAISY OAT .... INC. THE USE OF OR REPRODUCTION OF THIS DOCUMENT IS PROHIBITED EXCEPT AS AUrnORIZED BY DAISY DATA IN ....,.,llN~. SPECIFlCAllONS ARE SUB.JECT TO CHANGE WITHOUT NonCE.

12~1.!?~~~!~,~· MECHANICAL ASSEMBLY DRAWING

STAND ALONE V-PURGE MECHANICAL ASSEMBLY DIAGRAMS

B We Thrive in the Harshest Enviromncots Voice: (717) 932-9999 FAX: (J17) 932-8000 or Visit Us Atwww.daisydata..oom

Page 57: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

ir\ w , rr=w, -vw-

:[ ~O J ~ '. f--,

0 I " 0-~ ,-0

BASIC OVERALL DIMENSIONS

DAISY U~T

WALL MOUNT

DISPLAY SIZE x Y Z

TABLETOP MOUNT 15.0" 21.00" 15.44" 7.72" 19.0" & 22.0" 27.00" 18.98" 9.49"

L ____________________ ~ _________________ _____'

MODEL 2563KP: DIVISION MODEL 2566KP: DIVISION MODEL 2568KP: DIVISION MODEL 4563KP: DIVISION MODEL 4566KP: DIVISION MODEL 4568KP: DIVISION

DISPLAY SIZE H1 H2

15.0" 19.75" 31.25" 19.0" 24.75" 36.25" 22.0" 24.75" 36.25"

I

I I ~~IJ.~~D~WPLCS.) I

X-PURGE FLAT PANEL 15" MONITOR w/ KEYPAD I X-PURGE FLAT PANEL 19" MONITOR w/ KEYPAD I

X-PURGE FLAT PANEL 22" MONITOR w/ KEYPADL • X-PURGE 15" FLAT PANEL PC w/ KEYPAD ------, D X-PURGE 19" FLAT PANEL PC w/ KEYPAD X-PURGE 22" FLAT PANEL PC w/ KEYPAD •

I I

H3 W1 W2 D1 D2 D3 VH VW I N/A 19.00" 17.50" 7.50" N/A 11.25" 9.16" 12.16" I

I

N/A 25.00" 17.50" 7.50" N/A N/A 25.00" 17.50" 7.50" N/A

11.25" 12.01" 11.25" 11.815"

14.93" I 18.807" I

WALL MOUNT HOLE DIMENSIONS

DIMENSIONS ARE IN INCHES

THIS DOCUIoiENT IS PROPRIETARY TO DAISY OAT .... INC. THE USE OF OR REPRODUCTION OF THIS DOCUMENT IS PROHIBITED EXCEPT AS AU""",ORIZEC BY DAISY CATA IN _lllNG. SPECIFICATIONS ARE SUB.JECT TO CHANGE Wlll-iOUT NOnCE.

12~lR~~.!.!~,~· MECHANICAL ASSEMBLY DRAWING

We Thrive in the Hanib.llIIt Enviromnents VoieI!: (717) 932-9999 FAX: (717) 932-8000 or Visit Us Atwww.daisydata.oom. SHEET 1 OF 1 B

Page 58: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

IDR MEV

~-=------- -BASIC OVERALL

DIMENSIONS

DAIST UNT

TABLETOP MOUNT

PEDESTAL MOUNT

DAISY UNT

MODEL 9113

WASHER

DIIIST PEDESTAL

,,'g;,,~ ~~:,:,.oo: .

• 22.03 ... : I1I WALL MOUNT

DISPLAY SIZE 15.0"

19.0" & 22.0"

x Y

21.00" 18.98" 27.00" 18.98"

Z

9.49" 9.49"

f-------------------- ------------------~

MODEL 2663: MODEL 2666: MODEL 2668: MODEL 4363: MODEL 4366: MODEL 4368:

DISPLAY H1 SIZE

DIVISION DIVISION DIVISION DIVISION DIVISION DIVISION

H2

15.0" 23.25" 34.75" 19.0" 28.25" 39.75" 22.0" 28.25" 39.75"

X-PURGE FLAT PANEL INTEGRATED 15" MONITOR X-PURGE FLAT PANEL INTEGRATED 19" MONITOR X-PURGE FLAT PANEL INTEGRATED 22" MONITOR X-PURGE 15" FLAT PANEL INTEGRATED PC X-PURGE 19" FLAT PANEL INTEGRATED PC X-PURGE 22" FLAT PANEL INTEGRATED PC

H3 W1 W2 D1 D2 D3

3.50" 19.00" 17.50" 7.50" 16.50" 11.25" 3.50" 25.00" 17.50" 7.50" 16.50" 11.25" 3.50" 25.00" 17.50" 7.50" 16.50" 11.25"

I I

L--i •

D •

VH VW

9.16" 12.16" 12.01" 14.93" 11.815" 18.807"

I WALL MOUNT I HOLE DIMENSIONS

DIMENSIONS ARE IN INCHES

THIS DOCUMENT IS P~OP~IET""T TO DAISY DATA, INC. THE USE OF OR REPRODUCTION OF THIS DOCUMENT IS PROHIBITED EXCEPT AS AUTl-iORIZED 8Y CAISY DATA IN _'TlNQ. SPECIFICATIONS AFlE: 5UB..JECT TO CHANGE WITHOUT NonCE.

12~xR~~!~,~· STAND ALONE X-PURGE

MECHANICAL ASSEMBLY DIAGRAMS

MECHANICAL ASSEMBLY DRAWING B We Thrive in the Harshest Environments Voice: (717) 932-9999 FAX: (717) 932-8000 or Visit Us Atwww.daisyda1a.com

Page 59: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

II·:

BASIC OVERALL DIMENSIONS

ENa..o&URE ASlBI3LT

WALL MOUNT

TABLETOP MOUNT DISPLAY SIZE x Y Z

15.0" 21.00" 15.44" 7.72" 19.0" & 22.0" 27.00" 18.98" 9.49"

L ____________________ ~ _________________ _____'

MODEL 2553KP: NEMA 4X MODEL 2556KP: NEMA 4X MODEL 255BKP: NEMA 4X MODEL 4553KP: NEMA 4X MODEL 4556KP: NEMA 4X MODEL 455BKP: NEMA 4X

DISPLAY H1 H2 SIZE

15.0" 22.50" N/A 19.0" 27.50" N/A 22.0" 27.50" N/A

FLAT PANEL 15" MONITOR wi KEYPAD FLAT PANEL 19" MONITOR wi KEYPAD FLAT PANEL 22" MONITOR wi KEYPAD 15" FLAT PANEL PC wi KEYPAD 19" FLAT PANEL PC wi KEYPAD 22" FLAT PANEL PC wi KEYPAD

H3 W1 W2 D1 D2 D3

N/A 19.00" N/A 7.50" N/A N/A N/A 25.00" N/A 7.50" N/A N/A N/A 25.00" N/A 7.50" N/A N/A

I

I -,-~~IJ.~~WPLCS.)

I I

L __ ~

VH VW

9.16" 12.16" 12.01" 14.93" 11.815" 18.807"

1\ a

0) D = a

c:::x::::::J :

WALL MOUNT HOLE DIMENSIONS

DIMENSIONS ARE IN INCHES

THIS DOCUMENT IS PROPRIETARY TO DAISY OAT .... INC. THE USE OF OR REPRODUCTION OF THIS DOCUMENT IS PROHIBITED EXCEPT AS AUTl-iORIZEC BY DAISY DATA IN _111NO. SPECIFICATIONS ARE SUB..JECT TO CHANCE WITHOUT NOTICE.

12~lR~~!~,~· NEMA 4X NON-INTEGRATED "KP"

MECHANICAL ASSEMBLY DRAWING A We Thrive in 1IlII Hanib.llIIt Enviromnents VoieI!: (717) 932-9999 FAX: (717) 932-8000 or Visit Us Atwww.daisydata.oom.

Page 60: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

II·:

BASIC OVERALL DIMENSIONS

~~ ASSEMBLY

WALL MOUNT

TABLETOP MOUNT DISPLAY SIZE x Y Z

15.0" 21.00" 15.44" 7.72" 19.0" & 22.0" 27.00" 18.98" 9.49"

L ____________________ ~ _________________ _____<

r---'-

MODEL 2523KP: MODEL 2526KP: MODEL 2528KP: MODEL 4523KP: MODEL 4526KP: MODEL 4528KP:

DISPLAY SIZE

DIVISION DIVISION DIVISION DIVISION DIVISION DIVISION

H1 H2

15.0" 22.50" N/A 19.0" 27.50" N/A 22.0" 27.50" N/A

, L ~'4IJ-D~.DB~ Whcs.)

FLAT PANEL 15" MONITOR wi KEYP:~I FLAT PANEL 19" MONITOR wi KEYPAD FLAT PANEL 22" MONITOR wi KEYPAD

2 NON-INCENDIVE 2 NON-INCENDIVE 2 NON-INCENDIVE 2 NON-INCENDIVE 2 NON-INCENDIVE 2 NON-INCENDIVE

H3 W1 N/A 19.00" N/A 25.00" N/A 25.00"

15" FLAT PANEL PC wi KEYPAD 19" FLAT PANEL PC wi KEYPAD 22" FLAT PANEL PC wi KEYPAD

W2 D1 D2 D3 VH VW

N/A 7.50" N/A N/A 9.16" 12.16" N/A 7.50" N/A N/A 12.01" 14.93" N/A 7.50" N/A N/A 11.815" 18.807"

DIMENSIONS ARE IN INCHES

12~lR~~!~,~·

\ •

D J ! I ~ •

==:

WALL MOUNT HOLE DIMENSIONS

DIVISION 2 NON-INCENDIVE "KP" THIS DOCUMENT IS PROPRIETARY TO DAISY OAT .... INC. THE USE OF OR REPRODUCTION OF THIS DOCUMENT IS PROHIBITED EXCEPT AS AUTl-iORIZEC BY DAISY DATA IN _111NO. SPECIFICATIONS ARE SUB..JECT TO CHANCE WITHOUT NOTICE. MECHANICAL ASSEMBLY DRAWING A

We Thrive in the Hanib.llIIt Enviromnents VoieI!: (717) 932-9999 FAX: (717) 932-8000 or Visit Us Atwww.daisydata.oom. SHEET 1 OF 1

Page 61: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

"' If "' L

II·: I : I :-11

-~

~ , ~0~o~'

~d = 0

[:::::][:::::J :

BASIC OVERALL DIMENSIONS

-­ASSDlI LY

WALL MOUNT

TABLETOP MOUNT DISPLAY SIZE x Y Z

15.0" 21.00" 15.44" 7.72" 9.0" & 22.0' 27.00" 18.98" 9.49"

L ____________________ ~ _________________ ~

MODEL 2513KP: MODEL 2516KP: MODEL 2518KP: MODEL 4513KP: MODEL 4516KP: MODEL 4518KP:

DISPLAY SIZE

DIVISION DIVISION DIVISION DIVISION DIVISION DIVISION

H1 H2

15.1" 22.50" 30.00" 19.0" 27.50" 35.00" 22.0" 27.50" 35.00"

, ,

Y-PURGE Y-PURGE Y-PURGE Y-PURGE Y-PURGE Y-PURGE

FLAT PANEL 15" MONITOR w/ KEYPAD L~&:l.'or"/I'="h rl-----+--, FLAT PANEL 19" MONITOR w/ KEYPAD I FLAT PANEL 22" MONITOR w/ KEYPAD 15" FLAT PANEL PC w/ KEYPAD 19" FLAT PANEL PC w/ KEYPAD 22" FLAT PANEL PC w/ KEYPAD

H3 W1 W2 D1 D2 D3

N/A 19.00" 12.25" 7.50" N/A 5.00"

N/A 25.00" 12.25" 7.50" N/A 5.00"

N/A 25.00" 12.25" 7.50" N/A 5.00"

VH VW

9.16" 12.16" 12.01 " 14.93"

11.815" 18.807"

D •

c:::Jc:::J

WALL MOUNT HOLE DIMENSIONS

Page 62: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

"' r "'

Pm r---vw~O

[0 = 0

c:::Jc:::J : ---.r0.625"

--,

BASIC OVERALL DIMENSIONS

DAISY UNIT

WALL MOUNT

DISPLAY SIZE x Y Z

TABLETOP MOUNT 15.0" 21.00" 15.44" 7.72" 19.0" & 22.0" 27.00" 18.98" 9.49"

L ____________________ ~ _________________ ~

MODEL 2563KP: DIVISION MODEL 2566KP: DIVISION MODEL 2568KP: DIVISION MODEL 4563KP: DIVISION MODEL 4566KP: DIVISION MODEL 4568KP: DIVISION

DISPLAY H1 H2 SIZE

15.0" 22.50" 34.00" 19.0" 27.50" 39.00" 22.0" 27.50" 39.00"

I I

X-PURGE FLAT PANEL 15" MONITOR wi KEYPAD L~'·~~r."~)_rh~~9f_n X-PURGE FLAT PANEL 19" MONITOR wi KEYPAD --I X-PURGE FLAT PANEL 22" MONITOR wi KEYPAD X-PURGE 15" FLAT PANEL PC wi KEYPAD X-PURGE 19" FLAT PANEL PC wi KEYPAD X-PURGE 22" FLAT PANEL PC wi KEYPAD

D •

H3 W1 W2 D1 D2 D3 VH VW

N/A 19.00" 17.50" 7.50" N/A 11.75" 9.16" 12.16" N/A 25.00" 17.50" 7.50" N/A 11.75" N/A 25.00" 17.50" 7.50" N/A 11.75"

12.01" 11.815"

14.93" 18.807"

WALL MOUNT HOLE DIMENSIONS

DIMENSIONS ARE IN INCHES

THIS DOCUMENT IS PROPRIETARY TO DAISY OAT .... INC. THE USE OF OR REPRODUCTION OF THIS DOCUMENT IS PROHIBITED EXCEPT AS AUTl-iORIZEC BY DAISY DATA IN _111NO. SPECIFICATIONS ARE SUB..JECT TO CHANCE WITHOUT NOTICE.

12~lR~~!~,~· MECHANICAL ASSEMBLY DRAWING

We Thrive in 1IlII Hanib.llIIt Enviromnents VoieI!: (717) 932-9999 FAX: (717) 932-8000 or Visit Us Atwww.daisydata.oom. A

Page 63: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

Q) NOTES: TABLE 1

<D REFER m ALL LOCAL COPES FOR CONPUIT ENIRY ~F'pRMA]ONI THE TOP PLATE ON THE ENCLOSURE HAS THREE, 1 4 PILOT HOLES FOR CABLE ENTRY. DRILL ANY OF THE 3 HOLES TO THE CORRECT SIZE FOR YOUR CONDUIT OR CORD GRIP. IF CHOOSING TO ENTER THE ENCLOSURE AT ANOTHER POINT, EXAMINE THE INSIDE OF THE ENCLOSURE SO THE INTERNAL EQUIPMENT WILL NOT BE DAMAGED. CAREFULLY CLEAN THE INSIDE AFTER ATIACHING YOUR CONDUIT OR CORD GRIP.

'MiEN USING A CORD GRIP, SELECT A SIZE THAT WILL "GRIP" THE CABLES WITHOUT DAMAGING THE CABLES. DAISY DATA CAN PROIilDE THE FOLLOWING CORD GRIP SIZES: M290-0000OB: 0.25NPT, 0.156" CABLE DIA. M290-000001: 0.375NPT, 0.25" CABLE DIA. M290-000015: 0.375NPT, 5.5., 0.25" CABLE DIA. M290-000014: 0.375NPT, 0.3125" CABLE DIA. M290-000003: 0.5NPT, 0.1875" CABLE DIA. M290-000009: 0.5NPT, 5.5.. 0.187" CABLE DIA. M290-000014: 0.5NPT, 0.25" CABLE DIA. M290-000010: 0.5NPT, 5.5., 0.25" CABLE DIA. M290-000002: 0.5NPT, 0.375" CABLE DIA. M290-000012: 0.5NPT, 0.5" CABLE DIA. M390-000012: 0.5NPT, SEAL NUT ALL CORD GRIPS ARE ZINC PLATED STEEL EXCEPT M290-oo0015, M290-000oo9 &: M290-000010. THESE ARE STAINLESS STEEL

SEE TABLE 1 FOR THE DAISY DATA K'IM CATS INPUT CABLE MODEL NUMBER &: LENGTH.

MODEL 2553KP: NEMA 4X FLAT PANEL 15" MONITOR wi KEYPAD MODEL 2556KP: NEMA 4X FLAT PANEL 19" MONITOR wi KEYPAD MODEL 2558KP: NEMA 4X FLAT PANEL 22" MONITOR wi KEYPAD MODEL 2523KP: DIIIISION 2 FLAT PANEL 15" MONITOR wi KEYPAD MODEL 2526KP: DIIIISION 2 FLAT PANEL 19" MONITOR wi KEYPAD MODEL 2528KP: DIIilSION 2 FLAT PANEL 22" MONITOR wi KEYPAD MODEL 4553KP: NEMA 4X 15" FLAT PANEL PC wi KEYPAD MODEL 4556KP: NEMA 4X 19" FLAT PANEL PC wi KEYPAD MODEL 4558KP: NEMA 4X 22" FLAT PANEL PC wi KEYPAD MODEL 4523KP: DIIilSION 2 15" FLAT PANEL PC wi KEYPAD MODEL 4526KP: DIIilSION 2 19" FLAT PANEL PC wi KEYPAD MODEL 4528KP: DIIilSION 2 22" FLAT PANEL PC wi KEYPAD

.OOEL

9573

9565

9566

9567

9568

9"".

9570

9571

9572

9574

MODEL 2653: NEMA 4X FLAT PANEL INTEGRATED 15" MONITOR MODEL 2656: NEMA 4X FLAT PANEL INTEGRATED 19" MONITOR MODEL 2658: NEMA 4X FLAT PANEL INTEGRATED 22" MONlmR

LENG1Ii

25'

50'

100'

150'

200'

250'

JOD'

350'

<DO'

500'

MODEL 2623: DIIilSION 2 NON-INCENDIVE FLAT PANEL INTEGRATED 15" MONITOR MODEL 2626: DIIilSION 2 NON-INCENDIVE FLAT PANEL INTEGRATED 19" MONITOR MODEL 2628: DIIilSION 2 NON-INCENDIVE FLAT PANEL INTEGRATED 22" MONITOR MODEL 4353: NEMA 4X 15" FLAT PANEL INTEGRATED PC MODEL 4356: NEMA 4X 19" FLAT PANEL INTEGRATED PC MODEL 4358: NEMA 4X 22" FLAT PANEL INTEGRATED PC MODEL 4323: DIIilSION 2 NON-INCENDIVE 15" FLAT PANEL INTEGRATED PC MODEL 4326: DIIilSION 2 NON-INCENDIVE 19" FLAT PANEL INTEGRATED PC MODEL 4328: DIIilSION 2 NON-INCENDIVE 22" FLAT PANEL INTEGRATED PC

DIMENSIONS ARE IN INCHES

I2~~~l.?~~~~!~£. CABLE & CONDUIT ENTRY NON-

THIS DOCUMENT IS PROPRIETARY TO DAISY DATA. INC. PURGED 15" 19" & 22" ENCL. THE USE OF OR REPRODUCTION OF THIS DOCUMENT IS PROHIBITED EXCEPT AS AUTHORIZED BY I DRAWING NU··

POO 1 10"A DAISY DATA IN WRITING. SPECIFICATIONS ARE ELECTRICAL INPUT DRAWING SUB.JECT TO CHANGE WITHOUT NOTICE.

We Thrive ill the Harshest Envrronments V Olee: (717) 932-9999 FAX: (717) 932-8000 or Visit Us At www.daisydata.eom SHEET 1 OF 1

Page 64: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

OVER PRESSURE

EXHAUST

Main AC Power

Power

Boxes

• COSO-Ol POOO

MODEL 9026

~3~ES~§~= Signal Cables F -Only In thl. Conduit

PAC-SEAL KIT. 1" NPT REFER m pAC SEAl INSTRUCTIONS

MODEl. 2813: MODEl. 2816: MODEl. 2818: MODEL 4JIl: MODEl. 4.118: MODEL 4318:

Seal Fittings NPT

PAC Seal FIttings 1· NPT. 18- max from Enclosure

1 Y-PURGE FLAT PANEL ttTEGRAlED 1S- MONITOR 1 Y-PURGE FlAT PANEL INlEGRAlED 19- MONITOR 1 Y-PURGE FlAT PANEL INlEGRAlED 22- MONITOR 1 V-PURGE ,~ FLAT PANEL. IN1EGRAlED PC 1 V-PURGE U.- FLAT PANEl. IN1EGRAlED PC 1 V-PURGE 22- FLAT PANEL INTEGRAlED PC

Pressure Gouge, 0-160 PSI

@) TABLE 1

...... ....... ..,. '" .... 51 .... IIXI' OVER

PRESSURE /"")J34O M~:a~~al

ENCLOSURE '''''.L-, ~h;}-~~~~=~~/=~~:~~~3:f~~ ,,:pre •• ure RegUlator. 0-100 PSI I " M34Q 000171

0007 '''' .... "'" .... .... .... "" 11071 ""

MODEL 2S131CP: DIVISION 1 Y-PUVE FLAT PANEL 15- MONlroR _/ KEYPAD MODEl. 25181CP: DIVISION 1 Y-PUVE FLAT PANEL U.- MONlroR _I KEYPAD MODEl. 25181CP: DIVISION 1 Y-PUVE FLAT PANEL 2:2"' MONlroR _/ICE'l'PAD MODEL 45131CP: DIVISION 1 Y-PUVE 15- FLAT PANEL PC w/ KEYPAD MODEl. 45181CP: DIVISION 1 Y-PUVE 1.- FLAT PANEL PC w/ KEYPAD MODEl. 46181CP: DIVISION 1 Y-PUVE 22- FLAT PANEL PC wI KEYPAD

Pressure Relief Valve 2-125 PSI M34Q 000043

@

- Water &: 011 Separator FIlter M340-0QQQ24 Dassleant Refill COW-PODOl §

MODEL 9047 AIR CONNECTION KIT

REFER TO AIR CONNECTION INSTRUCTIONS

0072 .... ..,. ..... NOTES:

1'1\ RffFR m AI I 'mAl mJfS FQR CQMllIT ENTRY INBBlA'D(ItI1 \.II 1l£ USER ASSUMES TOTAl. RESPallSiBlUTY FOR CQIIIPlJANCE YI11H ALL APPLICABLE

COOES a: PROCEDURES IN THE FINAL "STAL.LATlON.

"" 1l£ PAC SEAl. FlTllNCilS CM BE A MAXNUM OF' 18- FROM 1l£ ENa.OSURE. v.I PAC SEAl.S MAY BE ATTAatED DIRECTlY TO THE ENa.osuRE a: THE RIGID CONDUIT

EXTENDED IN ANY CON't'ENENT DRC'nON. 11£ PAa<JNG FIBER I: THE SEAlING COMPOUND MUST COMPLE1EL Y SURROUNJ EAa-I CONDUCTOR OR CABLE.

11£ AR INPUT FIniNG IS A 1/4- NPT FEMALE. THE AIR SQlJRCE MUST BE a.EAN DRY tlSTRUMENT GRADE AIR CAPABLE OF' SUPPLYING 38 TO lao SCFH AT 20 - 100 PSI.

SEE TArI.E 1 FOR THE DAISY DATA CATS IIIFUT CABLE MODEl. NUMBER I: LENQ1H.

SHEET 1 OF 1

Page 65: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

CUSTOMER SUPPLIED AIR INPU TUNE

eD

AIR INPUT

Y-PURGE ASSEMBLY FRONT PANEL

REGULATOR, 20PSI BAll. VALVE FLOW .Em!

20 - 2DO sa:H

r----- ---- r----- r-- ;;;';-l I I I

1/'" HOSE 1/'" HOSE "'" HOSE

3/8"

I 1/'" NPIF 1/4- NPT I CONNECTION CONNECTION

1/4- NPT CONNECTlON

1/8- NPT CONNECTION

AIR INPUT I TO ENa.o5URE I

I INTERNAL PRESSURE SPARK PART (F EXHAUST I

I :ll~~~ ______________ ,-.m ~:I 1/8" HOSE

r-------------------~~----~ I YPA BOARD I

r-PRESSURE-----------, i I S'MlCH I I I 11100t"""""" I HIGH SIDE I I I LOW SIDE OTAS I I

STATUS I IE)

11~000852

RESET I S'MTCH

ALARM RELAY CONNECllON I I CONNECTIONS I I I OJSTOMER suppum

! D----------+-+-------~~;~;;Q' _~~~:;IE I SCREW TEROINALS I I EXHAUST

I L ______________ ~ I I L ________ ~~~-~ ______ ~ ________ ~

EQUIPMENT ENCLOSURE - -

MODEL 2613: DIVISION 1 V-PURGE FlAT PANEL INTERGRAlED 1ew MONITOR MODEL 2618: DIVISION 1 V-PURGE FlAT PANEL INTERGRAlED 19- MONITOR MODEL 2618: DIVISION 1 V-PURGE FLAT PANEL INTERGRAlED 22- MONITOR MODEL 4313: DIVISION 1 V-PURGE US· FlAT PANEL IN1ERGRAlED PC MODEl. 4318: DIVISION 1 V-PURGE 19- FlAT PANEl. IN1ERGRAlED PC MODEL 4318: DIVISION 1 V-PURGE 22- FlAT PANEL INlERGRAlED PC

MalEL 25131CP: DIVISION 1 V-PURGE leW FlAT PANEL MONITOR w/ KEYPAD MODEL 2516KP: 1 V-PURGE 19- FLAT PANEL MONITOR w/ KEYPAD MODEL 25181<P: 1 Y-PURGE 22- FLAT PANEL MONITOR w/KEYPAD hlOOEl. 451JKP: I 1 V-PURGE 15- FLAT PANEL PC w/ KE'tPAD hlOOEl. 4518KP: I 1 V-PURGE 19- FLAT PANEL PC _/ KE'tPAD MOOEL 451BKP: 1 V-PURGE 22- FLAT PANEL PC _I KE'tPAD

NOTES: "" THE AIR INPUT ATTlNG IS A 1/4· NPF FEMALE. THE AIR SOUCRE MUST BE CLEAN, DRY \.II INSTRUMENT GRADE AIR CAPABLE OF' SUPPLYING M TO 1eo SCFH FROM 20 TO 100 PSI.

"" THE V-PURGE ALARM BOARD (1DJJ-DD0002-03) IS LDCAlED ON THE RIGHT SIDE ~ FOR ALL MODELS SHOWN. A SIX CDNNCUCTOR CABl.E IS REQUIRED.

19\ FOR CABLE Ie CONDUIT ENTRY INTO THE ENa.DSURE, REFER TO \tU DRAWING ·POO2-.

CIMII!!!:N!510N!5 A"II!!!: IN INCI-III!!!:!5 D" D t I I Y-PURGE THIS DOCUMENT IS PRCPRETARY TO DAISY DATA. INC. 28'~~~Rood.!k!z..PAl}£" BLOCK DIAGRAM THE USE CIF OR REPRCIDUCTlC* CIF THIS DOCI.JMENT IS PROHIBllED EXCEPT AS AUTHORIZED ~~ rA DAISY DATA IN WRlTlNQ. SPECIFICATIONS AR NEUMATIC BLOCK DIAGRAM DRA WINGI-- POO3 SU""'~CT TO CHAN~ WITHOUT NOTIC ..

We Thrive m the Harshest EnVlI'OIllD.ents VOice. (717) 932-9999 FAX. (717) 932-8000 or Vl8lt Us At www.daisydata.com SHEET 1 OF 1

Page 66: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

Internal Pressure Meter ® M390-000086

o

Mounting Holes (14)~

<2> Flow Meter 0

20 200 SCFH---+--'---M 340- 00001 0 -

o II\WJ'''' IIII'cIl~~

=r:.::-"::='ft-==:

o o Exhaust Adjustment

@

NOTES: Exhaust

CD CONJROL VALVE: ADJUSTS THE AMOUNT OF AIR ENTERING THE ENCLOSURE I'I1TH THE PURGE/OPERATE CONTROL. SI'I1TCHES THE AIRFLOW INTO THE ENCLOSURE FROM PURGE TO OPERATE.

REGULATOR· ADJUSTS THE FLOW TO 150 SCFH DURING PURGE.

PRESSURE GOOD LED (pART OF JHE ALARM BOARD OPTION): THIS LED ILLUMINATES GREEN WHENEVER THE INTERNAL PRESSURE IS ABOVE 0.4" we &: THE ALARM RELAY IS RESET.

ALARM RESET SI'!1TCH (pART OF JHE ALARM BOARD OP]ON)· USED TO RESET THE CUSTOMER CONTACTS AFTER AN ALARM CONDITION.

DIFFERENTIAL PRESSURE BETWEEN THE ENCLOSURE &: THE EXTERNAL ENVIRONMENT. THE HOSE TO THE ZPA BOARD IS 1/8" BLUE.

®

®

Cl'ERATE

Control Valve <D M390-000087

0

0

0 Regulator, 20 PSI M 340- 000001 (2)

0

-Mi1 Pressure Good LED @

00 0 -~ Alarm Reset Switch ® - -

Atmosphere Sense ®

EXHAUST ADJUSTMENT &: EXHAUST ASSEMBLY; THE ASSEMBLY IS THE POINT AT WHICH PURGE AIR EXITS THE ENCLOSURE. THE ASSEMBLY ALSO INCLUDES THE ADJUSTMENT WHICH CAN CONTROL THE INTERNAL PRESSURE OF THE ENCLOSURE. WHEN THE CONTROL VALVE IS SET TO "OPERATE", ADJUST FOR A READING OF 1" we ON THE INTERNAL PRESSURE METER.

FLOW METER· MEASURES THE AMOUNT OF AIR WHICH IS ENTERING THE ENCLOSURE. THE READING IS TAKEN FROM THE MIDDLE OF THE SILVER BALL. DURING PURGE THE FLOW SHOULD BE 150 SCFH.

INTERNAL PRESSURE METER· READS THE INTERNAL PRESSURE OF THE ENCLOSURE. THE DIAL ON THE METER IS CUSTOMIZED TO READ OPERATE, OVER PRESSURE &: UNDER PRESSURE REGIONS.

DIMENSIONS ARE IN INCHES

THIS DOCUoIIENT IS PROPRIETARY TO DAISY DATA. INC. 1)£ USE OF OR REPROOUcnON OF THIS DOCUMENT IS PROHIBITED EXCEPT AS AUTHORIZED BY DAISY DATA IN WRI11NG. SPEClFlCAll0NS ARE SUB.JECT TO CHANOE WITHOUT NO"TlCE.

Dal" s Data Inc I Y-PURGE FRONT Y , " PANEL ITEM LOCATION

ITEM'LOCArtON'DIAGRAM DRAWING lORA .... ·"P004 I-A We Thrive m the Harshest Envrromnents VOIce: (717) 932-9999 FAX: (717) 932-8000 or Visit Us At www.daisydata.com Sl-lEET 1 OF 1

Page 67: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

1/4" n~'._,

Mounting Hole. (14)_-+0

Regulator. 20 ~~II-+_ K @ M34Q-OOQOOl

o

o

aD Breal:her-+--

Air Input_I-_-ID) for Y-Purge

(7)

CB)Atmoephere to VPA, 1/8" Hose

CD Control Valve

Exhaust

DIMII!!!:NSIONS A~II!!!: IN INCI-II!!!:&

lHIS DOCUMENT IS PRCFIIETARY TO DAISY DATA. INC. TI£ USE OF OR REPRODUC1IOH OfF lHlI DOCUMENT IS ~II!IITED EXC~ AS AUTHORIZED BY DAISY DATA IN 'MII.TlNa. "EaI"lCAT1ONB AllIE IIUIiiI..JIi:CT TO CHANGE W'lTHOUT NOT1CE.

Internal Pressure Meter (2)

o

o Flow Met.r Gl

o

o Hose

NOTES:

CD ~ ='t.ouNT Of AIR ENTERING THE ENa.osuRE "1H THE PURGE/OPERATE CDlTRCL SMfT'OtES THE AIRFLOW INTO THE ENa.osIJRE FROM PURGE TO OPERATE.

'"DNA! pefSS BE MElEB; READS THE INTERNAL. PRESSJRE OF THE ENa.DSURE. 11£ DIAl.. ON THE METER IS CUSTOMIZED TO READ OPERATE. O'e PRESSURE I: UNDER PRESSURE REGIONs.

BOW Mf!ER; MEASURES 11£ AMOUNT OF' AIR '"at IS ENlERING THE ENa.OSURE. THE READING IS TAICEN FROM THE MIDDLE Of THE Sl.\9 BAU.. DURING PURGE 1l£ FLOW SHOULD BE 150 saH.

ENg Q5' 'BE AIR HIUT; THIS IS AIR INPUT INTO 1l£ ENa.osuRE. 1l£ OUTPUT Of THE FlOW ME1ER IS A 3M lUBE. THE EN) OF lHS rulE IS PLACED AT THE OPPOSITE CORNER FROIII THE EXHAUST ASSEMEl. Y. THIS n&: MUST BE UNEII..OQ(ED.

ExtfN 1ST ApUilMfNT " EXHAUST WifHII 'C THE ASSEMELY IS 1l£ POINT AT Mtlat PURGE AIR EXITS THE ENa.osuRE. THE ASSEt.a..V ALSO INQ.UDES THE AD..USTWENT YHat CAN CON1RQL THE INTERNAL PRESSURE OF' 11£ ENQ.OSIJRE. IIHEN 11£ CONTROL VALVE IS 'SET 10 -OPERATE", AO..UST Fm A READING OF' ,- we ON 11£ INTERNAL PRESSURE MElER.

AJl4QSPHfBE VSE· USED BY THE PRESSURE SWI10t ON THE VPA BOARD 10 GET DFFEREN1IAL PRESSURE BE1WEEN THE ENa.OSURE It THE EX1ERNAI.. EN't'IRDNIIIENT. THE HOSE 10 11£ "tPA BOARD IS 1/8- BLUE.

NB 'M'l'T FpB Y-fl'R· ATTAatIllENT POIIIT Fm THE ENa..05URE'S PURGE AIR OR .. ERT GAS. THE Aft SOl.RCE MUST BE a.EAN DRY INSTRUMENT GRADE AIR CAPABLE OF' SUPPL"I'ING :so 10 150 SCFH AT 20 - 100 PSI. THE ENQ.OSIJRE IS PURGE AFTER 10 MINUlES 11TH A FLOW OF' 150 SCFH. AFTER 11£ PURGE IS CONPI.E1E. THE SYSTEM 11Ll. REQUIRE ON..Y AN AMOUNT OF AIR ENOUGH 10 MAlfTAIN THE ENQ.OSIJRE PRESSURE AT 1- we. :pARK MPE5'JEB PRE\9ITS Fl.ANE FROM EXJ'l'WQ 11£ ENQ.OSURE.

PEP' A1T'B. AO..USTS 11£ FLOW 10 150 SCFH DURING PURGE.

D · D t I I Y-PURGE BACK PANEL 28S~~XRood.~~J..PA~£· I_ITEM LOCATION

ITEM LOCATION DIAGRAM DRAWING POOS r: We Thrive m the Harshest Environments Vmce. (717) 932·9999 FAX. (717) 932-8000 or Visit Us At www.daisydata.com SHEET 1 OF 1

Page 68: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

OUTSIDE ENCLOSURE

Seal Nut, 3/4NPT----.... M390-000015 "

Breather, 3/4NPT __ 0-M3Z3-000010 0-

<2> ~

INSIDE ENCLOSURE

Check Valve, O.5PSI, 3/4NPT -M390-000094

CD

n Coupling, 3/4NPT, F-F W -M390 000060

Elbow, 3/4NPT, M-F -M390-000058

NOTES: '1' CHECK VALVE Q 5 pSI· \JI lHE CHECK VALVE \\1LL OPEN IF lHE INTERNAL PRESSURE IS GREATER lHAN 0.5 PSI.

lHlS \\1LL PREVENT OVER PRESSURIZATION OF lHE ENCLOSURE.

BREATHER· lHE BREAlHER ALLOWS AIR TO EXHAUST FROM lHE ENCLOSURE, BUT DOES NOT ALLOW SPARKS TO EXIT lHE ENCLOSURE.

SHEET 1 <F 1

Page 69: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

Pour Sealing Compound here

Enclosure Wall /

for Horizontal Installation. C040-Q1QQQl

gl~~~:~~:~~:~d here

MODB.. 2683: DIVlSlCIII 1 X-PURGE FLAT PANB.. 15" INlEGRATED MONTCR MODB.. 2688: DIVlSlCIII 1 X-PURGE FLAT PANB.. 19- INlEGRATED MONTCR MODEL 2888: DI\1S1C111 1 X-PURGE FLAT PAt£I.. 22- INlEGRATED MONITCR MODEL ~ DIVISION 1 X-PURGE usM FLAT PANB.. IN1EGRATED PC MODEL 43S0: DIVISION 1 x-PURGE 19" FLAT PANB.. IN1EGRATED PC MODEL 4368: DI\1S1C111 1 X-PURGE 22M FLAT PANB.. INlEGRATED PC

Power Cables thOU9h __ ~§i~~~i~i~~~;;~~:~~~~~c:' PAC Seal PAC Seal. 1"NPT

EXPlosion~~.~i.:=--1IiOR- ~1I"""'I1 I/o CD

OlQDOQ

Boxes MODEL 9026 MJl1ll:::llll!i1lllI~ PAC-SEAL KIT. 1" NPT

Cables ==='--O~y In this Conduit

Seal Fittings NPT Fittings

REFER TO pAC SEAl INSTRLJC]QNS

1· NPT. 18* max from Enclosure

Enclosure Wall

Pressure Gauge. 0-160 PSI M340-000042

/ Mechanical / Shut Off Valve 100 PSI r M390-000004 ~Pressure Regulator. 0-

}-~~~~~~~~~~~~/===f-~-=-=-==-=-~-~-:-:-~~/~=>M340-0QQ171 "--Pressure

Relief Valve 2-125 PSI M34Q QQQ043

@

- Water &: 011 Separator Filter M34Q-OQQQ24 Desslcant Refill CQ4Q-QQQQ16 NOTES:

CD

® TAII.E 1

M ..... ...... 1573 s· .... Sf .... ,GO' ..., ,,.. .... "'" .... 2JIJt ..,.

"" 1071 "" 01172 ..... .. ,. ....

ALL APPUCAEIlE

MODEL 9047 lHE PAC SEAL FITTINGS CAN BE A MAXIMUM OF IBM FROM Tl£ ENa.osuRE. AIR CONNECTION KIT

REFER TO AIR CONNEC]QN INSJRUC]ONS PAC SEALS MAY BE ATTACHED DIRECTLY TO lHE ENa.osuRE 6: lHE RIGID CClllDUIT EXlENDED IN ANY CONVENIENT DlRECllCIII. lHE PAO<iNG FIBER a: lHE SEALING COt.IPOUND MUST COMPLETELY SURROUND EAai CONJUCTOR OR CABLE.

lHE ~ INPUT FITTING IS A 1/4M NPT FEMAlE. lHE AIR SOURCE MUST BE a.EAN DRY INSTRUMENT GRADE AIR CAPABLE <F SUPPLYING 40 TO 300 saH AT 30 - 80 PSI.

SEE TABLE 1 FOR lHE DAISY DATA CAT5 INPUT CAEIlE MODEL NUMBER a: LENGlH.

MODEL 2583KP: DIVlSlCIII 1 X-PURGE FLAT PANB.. usM MCIIIITOR w/ KEYPAD MODEL 2588KP: DIVlSlCIII 1 x-PURGE FLAT PANB.. 19- MCIIIITOR w/ KEYPAD MOOB.. 258E1(P: DIVISION 1 X-PURGE FLAT PANB.. 22- MCIIIITOR w/ KEYPAD MODEL 4583KP: DIVlSlCIII 1 X-PURGE usM FLAT PANB.. PC w/ KEYPAD MODEL 4M8KP: DIVlSlCIII 1 X-PURGE 19M FLAT PANB.. PC w/ KEYPAD

MOOB.. 4eS8KP: DIVISION 1 X-PURGE 22" FLATrP~ANgEL~P~C~'~/~K""~~AD~~~~g~~~~-lr~i1~~;-"r~rl;~lTiiC;--1::-~~~~~Jg;~5.P~J],~~::l ~OI"'ENSIONS ARE IN INCHES D· D tIl CABLE & CONDUIT ENTRY lI:~''f..,.'''',l':;\''u'J~J;og.~V8£,\~ alSV a a, nco X-PURGED 15" 19"& 22" ENCL. IS PftOHllIlTI!:D EXCEPT AS AU'THO"IZED lilY 2850 Lewisb4Road. York Haven,. PA 17370 IDRA.NGNlMERpnnn~ I-;BO g~;~E~~TA,.bN ~~8E s:.~'6~.rC:JT1~l ELECTRICAL INPUT DRAWING t"uv I I t

We Thrive in 'the Harshest Environments Voice: (717) 932-9999 FAX: (717) 932-8000 or Visit Us At www.daisydata.com SHEET 1 OF

Page 70: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

@ Air In Connection Reaulatl>r (j)

Point - 1/'r4=-"-...:.:N=-P.:.T:::::::~ ______ +~~~~~~.r_~A~ir~l~n~B~ox@z='l&

Mounting Holes

Exhaust Valve Assembly Kit @ 1640-000449-04 Under the Air In Box

Intrinsic 8 Volt -

Intrinsic Safety ® 6 Volt - E903-000009

o

o

o

Intrinsic Safety Barrier-+-+lo.L..-t 6/16 Valt - E903 000016

pur&;, Status Cable

~ ==--= • o -..:~:. ---o

o

o

o

o o o

o

Explosion Solenoid

E114-00001 0 (l)

Casting Screws (14) ®

Power Interface Board I I

I/O Conduit Connection I--F-+-~Inin+ 3/4" NPT CB)

I/O Conduit Connection """""'=---+-Pnin+ - 3/4" NPTCB)

Board ~~-------1[~~~~e

o o o

NOTES:

(J) r::.=..:: RElWLA~ GIVES 1t£ USER CONTROL OVER 1t£ AIR PRESSURE. .Ii: THEREFCRE. THE FLOW COIG INTO 1t£ ENa.DSURE.. lHE PRESSURE SHOll.D IE SET IE'T1EEN 20 • 80 PSI. AN ADJJsn.tENT CF' 80 PSI WIll. GI'.£ A FLOW RATE CF' APPROXIMAlELY ~ 5a'H wmt AN INTERNAL PRESSI.R: .. SIDE THE ENCt..05I.R: OF' 8- OF' WA1ER COLLIIN.

PRES' BE t€JEB; READS 11£ PRESSURE OF THE Aft ItAll FOR 1t£ ENa..OSI.IE

E!'P' OSK'" pacq 91 fN"D nlS ALLOWS 1l£ PLACED Aft INTO 1l£ ENaDSURE.. IPERATES ON +24 Valbi DC.

,tgc·5D'P~

PfWB pt'll'Rl"&CE...EID!'''l: SEE DRAYIiNCf"E61¥FOR DETAL ItEaWAllCN. lin .QIII IIr <p!NfGIK!!' A 37..,. ENTRANCE INTO TI£ CAST AWMINUM BOX. SEE I:RAIING -poor FeR CCNlUIT ~ECTION 10 THE ENa..osuRE. _N .. 1lH!III. .......

SEE DRAflllNii'EOifi?Oi( IETAL IN'tRIAllCN.

SEE DRAWl; FOR DETAL INFCRMAlION.

B'RQE ljI6D'S GeB E' TI£ CMLE. "00-000705. IS Tl£ lRI-coL.ORED LED STATUS 1N:IICA'RlR USE 10 RELAY IJRRMAlION TO lHE USER. A STEADY RED AT STARlU'" IlCIICAlED 11£ INTERNAL PRESSURE and/or Aft FLOW IS 100 LOW FOR ADEQUATE PURClNG. A STEADY YELLOW INDICATES THE PURGE IS IN PROGRESS. A FLASHING YEll.OW INDICATES OVERFLOW, 11£ REGULAlOR SHOll.D IE lURNm DCMI SUGHlLY. Ii STEADY GREEN INDICATES 11£ PlRGE IS COMPLE1E. A FLASHING GREEN INDICATES 11£ PURGED IS B'l'PASSED. F AN ERROR OCCLRS DURING OR AF'1ER Tl£ PlRGE Tl£ LED WIll. FLASH RED IN A CXIDE. TI£ ERROR CODES ARE US1ED BY TI£ Il.INGNG CF THE RED LEO. 1-1= SYSTEM ERROR. (CDISULT FACltIRY) 2-1: lItDER PRESSURE 2-2: 0't'ER PRESSURE ~2: OVER FLOW 3-3: WATER DE1EC1ED (ONLY WITH WAlEA COOLER CPTlON ON ENCLOSURE) 4-1: FMlLTY PRESSURE SENSOR 4-2: FAl.LTY FLOW SENSOR 4-~ 5tORT PURGE BIJT'T'C»I IS STUCK a.osm 4-41 PUReE BYPASS III.IT1'CW IS STUD< a.osm

EItINI!iJ' YN \IE !S5fMW r KID lItS YALI£ OPENS DI.RIIG PURGE 10 EXHAUST 11£ Pl.RCE Aft. ONCE THE PURGE IS COMPLETE 11£ YALI£ a.osES <II: Wu. NOT REOPEN LroILESS 11£ INTERNAL PRESSURE RISES ABO't'E r 'lit: OR 11£ PlRGE IS LOST.

11£ ATTADiMENT POINT Fa:« 11£ ENa..OSI.RE"s PURCE AIR IS 11 ... - NPT FEMALE FmlNG. THE AR SOURCE MUST EE a.EAN DRY INSTRUMENT GRADE AlMNERT GAs CAPABLE OF SUPPI. VlNG 40 -300 9a'H • 3D - eo PSI. 11£ ENa..OSI.RE IS pURGEb AFTER ... \'OI.UNES OF AIR HAI£ PASSED THOUGH IT. AF1ER 11£ PUReE IS cot.Ft.E1E THE SYS1DI Wu. REQURE ON. 'I' ENOUGH AR 10 MAINTAIN 11£ ENa..OSURE PRESSURE ABO't'E 1.0" OF 1IC.

Page 71: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

<D Air Inlet

0 0

0 0 • Exhua.t Valve A •• ebmly Kit I C2>

NOlES: 0 0 <D flUg AIR INI fT"

0 0 THIS IS THE POINT lHE PURGE AR Wl.L ENlER 1l£ ENa.OSURE. 1l£ 1/4- lUBE SHOULD BE FREE OF' DIRT • KN<S.

(2) EXHAI'ST \IN \If !'§fHBI Y KID

® THIS VALVE IPENS DlRNG PURGE TO EXHAUST 11£ PlRGE AIR. ONCE 11£ PURGE IS COMPLETE THE VALVE a.osES Ii: YIILL NOT RECJIEN UNLESS THE INTERNAL PRESSURE RI!ES ABOVE 8- we

1.5. Pack OR THE PURGE IS LOST.

• (3) 6D4mFttf8f VSE-Internal Interface Board ALLOWS THE PRESSURE SENSOR ON THE PURGE CON1RClL BOARD 10 MEASURE THE DlFFERENlIAL

I 5 @) PRESS!..-: BETWEEN 11£ ENa...cJSlR I:: THE SlRWUNDlNG EN\1RONMENT.

@) "1[BNAI 5'~ '~MJ:' M!,,): SEE DRAWING 01 FOirDETAl. INFllRIIIAllON

® 0 • • 0 @ fltiV qwmq ene' Power I/O Pack ~ ~ m

LOCAlED UNDER THE RF SHELD BOX. SEE DRAWING -E021· FOR DETAIL INFeRlAlION.

es> lip 5'!JQt M~ Mepp' SEE ORA.Nt FOR DETAL INF'ORMATION.

0

~ (2) Rf SHE! D AQX:;

~ ~ PROTECTS TI£ PlRGE CONTROl. BOARD FROM RF RADIATION THAT YIOOLD RESET THE PURGE SYSmI.

@ ® PnWnf -;r PAC $EAI' 'THJSiV5EAL CONTAINS Tl£ AC POYI£R CAlLE FOR THE INTERNAL EQUIPMENT. +24V CAlLE FOR THE SOLENOI) I: 3 DATA CABlES WITH e PAIRS IN EAQt CABlE. Tl£ PAC SEAL HAS THE SEAlING

0 COMPOUN) THOUGH rrs LENGTH .t CAN NOT BE RE-POSIS1IONED.

~ ~ @ 'S PAC SEA"

THIS PAC SEAL CONTAINS 11£ .. 1RINSICALLY SAFE POWER CAlLE I: THE ENa.osuRE REDUNDANT 0 0 GRQtN) ~ THE PAC SEAL HAS THE SEAUNG COMPOUND THOUGH IT'S LENGTH

• • I: CAN NOT BE RE-POiSISllONED •

® pll QI AIR EEfD' THIS AR L.N: PROVIDES THE PLOT PRESSURE FOR THE EXHAUST SOLENOID •

• Board RF Shield (l)

0 0

0 0 0 0

WeThriveintbeHarrihe!itEuviromnenIli Voice: (1\1) 932-9999 FAX:fll7)932-l1OOO orVJSitUsAtwww.daisydatLcom stEEl' 1 CF 1

Page 72: Flat Panel User ManualUser Manual D012-000000 . Flat Panel User Manual . May 2015 . Daisy Data Displays, Inc. 2850 Lewisberry Road . York Haven, PA 17370 . 717.932.9999

CUSTDNER SUPPUED AIR INPUT UNE

EQUIPMENT ENCLOSURE ,-------,

AIR INPUT ,-----,

REGULATOR 125 PSI

----- f---

EXPLOSION PRCXF SOLENOID

,-----,

ENQ.OSURE I AIR INPUT I

1/," HOSE

L..-,----' 1/4" HOSE '-0---."'" HDSI_L-r--:-'

, "'" NPlF ' 1/'" NPT 1/'" NPT 'I ICONNECTION I CONNECTION CONNECTION I 1/8" HOSE 1/8" HOSE 1, _________ --1

I II I III P'LOT PRESSURE I I AIR 'NPUT

I AIR 'NPUT PRESSURE II 1/8" I METER, 0 - 100 PSI HOSE

I ---I i: L _____ I- __ -.l I 1/8" NPT

AIR IN BOX CONNECTION

r-------------J I

-y- F1T11NG FLOW lUBE

EXHAUST SOLENOID

10-32 CONNEC11C111

1/8" HOSE

I I

1/," lUBE I ----'- I

I I I I I

EXHAUST I PLUNGER

10-32 .! FONNECTI"'1

MODEL 2663: DIVISION 1 X-PURGE FLAT PANEL INTEGRAlED 15- MONITOR MODEL 2666: DIVISION 1 X-PURGE FlAT PANEL INTEGRAlED 19- MONITOR MODEl 2868: DIVlSIQII 1 X-PURGE FLAT PANEL INTEGRAlED 22- MONITOR MODEl 4363: DIVl5IQII 1 X-PURGE 1~· FLAT PANEL INTEGRAlED PC MODEl 4366: DIVl5IQII 1 X-PURGE 19- FLAT PANEL INTEGRAlED PC MODEL 4388: DIVISION 1 X-PURGE 22- FLAT PANEL INTEGRATED PC

II A TIMOSPHERE

SENSE r'----, AIR INPUT

TO ENQ.OSURE 1/'" NPT

CONNECTION

I

1/8" HOSE

1/8" HOSE

SAPC BOARD r---------------,

PORT A

PRESSURE SENSOR

PORTA

J17

MTA3

J15

FLOW I SENSOR I

I I I

MTA< I

STATUS LED

1100-000705

SHORT I PURGE

1100-000704

MODEl 2563KP: DIVISION 1 X-PURGE FLAT PANEL 15- MONITOR wi KEYPAD MODEl 2566KP: DIVISION 1 X-PURGE FLAT PANEL 19- MONITOR w/ KEYPAD MODEL 2568KP: DIVISION 1 X-PURGE FLAT PANEL 22- MONITOR w/ICE'YPAD MODEL 4563KP: DIVISION 1 X-PURGE 15- FLAT PANEL PC w/ KEYPAD MODEL 4566KP: DIVISION 1 X-PURGE 19- FLAT PANEL PC w/ KEYPAD MODEL 4568KP: DI\1S1ON 1 X-PURGE 22w FLAT PANEL PC w/ KEYPAD

NOTES: (j) lHE AIR INPUT FlTTlNG IS A 1/4- NPF FEMALE. lHE AIR SOUCRE MUST BE CLEAN,

DRY INSTRUMENT GRADE AIR CAPABLE OF SUPPLYING 40 TO 300 SCFH AT 30 TO 80 PSI.

(2)

C3> L ___ ~-~~~'~8-~-~~~~~~ ____________ J lHE SHORT" BYPASS PURGE SWiTaiES ARE LOCAlED UNDER lHE

4.:Sw x 2- COVER ON lHE LEFT OF lHE PURGE PANEL

FOR CABLE Ie CONDUIT ENlRY INTO lHE ENa.OSURE. REFER TO DRAWING wpoor.

DIMENSIONS ARE IN INCHES D" D t I I STAND ALONE X-PURGE THS DOCUMENT IS PROPRETARY 10 DAISY DATA, INC. alSY a a, nco PNEUMATIC BLOCK DIAGRAM THE USE OF' OR REPRCOUCllON OF' THIS DOCUMENT IS PROHIBITED EXCEPT AS AUTHORIZED ~S NEuMATICBLOCKDrAG'RAM3DRA WINGI ........ ""·POlO I~A DAISY DATA IN WftIl1NG. 5P~II"1CAl1ONS A SUB,JECT TO CHANCE WITHOUT NOTICE ..

We Thrive m the Harshest EnVllOIlIDents VOIce: (717) 932-9999 FAX: (717) 932-8000 or VISlt Us Atwww.daisydata.com SHEET 1 OF 1