7
FLANGED VALVES PENTAIR CLEAN AIR SYSTEMS

FLANGED VALVES - · PDF file1.Prepare inlet flanges and blowtube pipesouit t s valve specification. Avoidnstalling i valves underneath theank. t 2. Ensureank t and pipes are free

  • Upload
    doanh

  • View
    220

  • Download
    4

Embed Size (px)

Citation preview

Page 1: FLANGED VALVES - · PDF file1.Prepare inlet flanges and blowtube pipesouit t s valve specification. Avoidnstalling i valves underneath theank. t 2. Ensureank t and pipes are free

FLANGED VALVESPENTAIR CLEAN AIR SYSTEMS

Page 2: FLANGED VALVES - · PDF file1.Prepare inlet flanges and blowtube pipesouit t s valve specification. Avoidnstalling i valves underneath theank. t 2. Ensureank t and pipes are free

02

•EMC2004/108/EC(CA)

•LowVoltageDirective2006/95/EC(CA)

INSTALLATION1.Prepareinletflangesandblowtube

pipestosuitvalvespecification.Avoidinstallingvalvesunderneaththetank.

2. Ensuretankandpipesarefreefromdirt,rustorotherparticulate.

3.Ensuresupplyairiscleananddry.

4.Mountvalvestoinletflangeandblowtubetovalveswithallsealsinplace.Tightenflangeboltsto10Nm(7.4ft–lbs)Ensureblowtubeispushedallthewayintothevalveoutlet.

5.Tanksandpipesmustbeindependentlysupportedfromvalve.

6.MakeelectricalconnectionstosolenoidorconnectRCApilotporttopilotvalve(RCAvalvesonly).

7.Applymoderatepressuretosystemandcheckforinstallationleaks.

8.Fullypressurisesystem.

9.Testfireandlistenforproperactuationandcrisppulsenoise.

Valve is not a structural component. Do not rely on valve to retain tanks or pipe. Whereused,refertoDEINC-002productspecificationforinstallationdetails.

DESCRIPTIONVeryhighperformancediaphragmvalvewithflangedinletportandslidesealoutletportforeasyvalveinstallationandremoval.Availablewithintegralpilotorasremotelypilotedvalve.Outletat90°toinlet.

SUITABLE FORDustcollectorapplications,inparticularforreversepulsejetfiltercleaninganditsvariations,includingbagfilters,cartridgefiltersandenvelopefilters,ceramicfiltersandsinteredmetalfibrefilters.

CONSTRUCTIONBody:Diecastaluminiumor316stainlesssteelFerrule: 305SSArmature: 430FRSSSeals: NitrileorVitonSpring:304SSScrews: 302or304SSOutlet Slide Seal: EPDMorVitonDiaphragm Seat:PA-66(standard),Vitoncoatedmildsteel

RefertoQSeriesSolenoidproductdatasheetforsolenoidconstructiondetails.

OPERATIONRecommended on-time range: 50–500msRecommended time between pulses:1minuteorgreater

MAINTENANCEBeforeconductinganymaintenanceactivityonthesystemensurethatcomponentsarefullyisolatedfrompressureandpowersupplies.Pressureandpowershouldnotbereapplieduntilthevalvehasbeenfullyassembled.

Diaphragmandpilotinspectionshouldbeconductedannually.

APPROVALS•AtexII2DMechanical(RCAOnly)

•CSA(C,US)[C22.2No139–10andUL429:2009](CA&RCA)

•C-Tick(CA)

SIZE OD mm OD inches

1.5˝ 48.3 1.900

WerecommendSchedule40thickness.

WEIGHTS

SIZE INTEGRAL PILOT (CA) kg (lb)

REMOTE PILOT (RCA) kg (lb)

45 1.830(4.03) 1.610(3.55)

MAINTENANCE KITS

MODEL NITRILE VITON INCLUDES

CA/RCA45FS K4502 K4503K4542(Viton/SS)K4544(Viton/SSMainDiaphragmonly)

Diaphragmkitsincludemainandsecondarydiaphragmsandallsprings.

CAC45FStoCA45FSIntegralpilotcoverconversionkit

K4532(NPT)K4538(RC)

K4537(NPT)K4539(RC)

ThecompleteCAintegrallypilotedvalvecoverassembly.Doesnotincludecoverboltsormainbleedpin.

RCAC45FStoRCA45FSRemotepilotcoverconversionkit

K4533(RC)K4535(NPT)

K4534(RC)K4536(NPT)K4543(NPT/SS)

ThecompleteRCAremotelypilotedvalvecoverassemblywithmaindiaphragmandspring.Doesnotincludecoverboltsormainbleedpin.

Integralpilotrepairkit(CA45FSandCAC25FS)

K0380 K0384 O-ringarmatureassembly,armaturespring,ferrule.

Integralpilotrepairkit(CAC45FS)

K0390 N/A O-ringarmatureassembly,armaturespring,ferrule.

45FSOutletseal G690864 G690864-2 Outletseal

GOYEN ‘FS’ SERIESPULSEJETVALVES

FSSeries

Page 3: FLANGED VALVES - · PDF file1.Prepare inlet flanges and blowtube pipesouit t s valve specification. Avoidnstalling i valves underneath theank. t 2. Ensureank t and pipes are free

03

RCA 45 FS 0 1 0 301

RCA=remotely pilotedCA=integral pilot

Pilot type

45 mm

Valve size

0=1/8″ or CA1=1/4″

Pilot size

0=NPT1=RC9=NPT and stainless-steel valve body

Pilot thread type (RCA), Exhaust thread (CA)

0=Nitrile1=Viton

Diaphragm material

Coil type for CA only. See the RCA3 Solenoid Pilot Valvesbrochure for coil options.

Solenoid type

PRODUCT CHARACTERISTICS AND PERFORMANCE

NOM. SIZE PORT SIZE NUMBER OF DIAPHRAGMS

FLOW PRESSURE RANGE TEMPERATURE RANGE °C °(F)

mm in KV CV kPa (psi) NITRILE SEALS VITON SEALS

45 40 1.5 2 56 65 30(5)–860(125) –40(–40)to82(179.6) –29(–20.2)to232(449.6)

ORDER CODE

Examples: CA45FS010-3001.5˝FSvalvewithnitrilesealsand220/240VACintegralpilotwithDINsocketterminals.

RCAC45FS0911.5˝FSvalvewith1 8˝NPTremotepilotport,stainlesssteelbodyandvalvecover,andvitonseals.

DIMENSIONS(Dimensionsinmmand[inches])

CA/RCA45FS

GOYEN ‘FS’ SERIESPULSEJETVALVES

Page 4: FLANGED VALVES - · PDF file1.Prepare inlet flanges and blowtube pipesouit t s valve specification. Avoidnstalling i valves underneath theank. t 2. Ensureank t and pipes are free

04

GOYEN RCAC20FS4

SUITABLE FORDustcollectorapplications,inparticularforreversepulsejetfiltercleaninganditsvariations,includingbagfilters,cartridgefiltersandenvelopefilters,ceramicfiltersandsinteredmetalfibrefilters.

CONSTRUCTIONBody:Aluminium(diecast)

Screws: 304StainlesssteelSeals: Inlet O-ring:Nitrileusedwithshockwavediaphragm,VitonwithVitondiaphragm

Outlet:EPDMusedwithshockwavediaphragm,VitonwithVitondiaphragm

Diaphragm:Proprietaryhigh-performanceengineeringthermoplasticElastomerorViton

OPERATIONRecommended on-time range: 50to500msRecommended time between pulses:1minuteorgreater

MAINTENANCEBeforeconductinganymaintenanceactivityonthesystemensurethatcomponentsarefullyisolatedfrompressureandpowersupplies.Pressureandpowershouldnotbereapplieduntilthevalvehasbeenfullyassembled.

Diaphragmandpilotunitinspectionshouldbeconductedannually.

APPROVALSTheRCAC20FS4meetstherequirementsoftheEuropeanLowVoltageDirective2006/95/EC,whenfittedwiththeRCA3PVpilot.

REVERSEPULSEJETVALVES

Please Note:WerecommendusingSchedule40pipe.ThicknessODisasshownbelow.

SIZE OD mm OD inches

¾˝ 26.67 1.05

WEIGHTS

VALVE kg (lb)

RCAC20FS4 0.51(1.12)

MAINTENANCE KITS

MODEL SHOCKWAVE VITON

Diaphragm KitRCAC20FS4 K2034 K2033

20FS4 Outlet SealRCAC20FS4 G690338 G690338-2

PRODUCT CHARACTERISTICS AND PERFORMANCE

NOMINAL PORT SIZE mm (in.)

NO. OF DIAPH.

FLOW KV (CV)

PRESSURE RANGE kPa (psi)

TEMPERATURE RANGE °C (°F)

SHOCKWAVE VITON

20(¾) 1 19(26) 30(5)to860(125)

–40(–40)to82(179.6)

–29(–20.2)to232(449.6)

DESCRIPTIONHigh-performancediaphragmvalvewithaflangedinletportandslidesealoutletport.Equippedwith‘Shockwave’springlessdiaphragm.The4seriesvalvesareavailableasremotepilotvalvesandmaybeconvertedtointegralpilotusingeithertheRCA3DMorRCA3PVscrew-inpilots.Outletisat90°toinlet.TheFSvalverangefeaturesalargerdiameterinletprovidinghigherperformancethantheDD,TorSTbodystyles.

Examples:RCAC20FS4012¾˝FSvalvewith1 8˝RCpilotportthreads,Shockwavediaphragm.”

Note:1 8PilotavailableinNPT,RCandGThread.¼PilotisonlyavailableinGThread.

ORDER CODE

DIMENSIONS(Dimensionsinmmand[inches])

0=1/8″1=1/4″

RCAC20FS4Diaphragm material

1=Viton2=Shockwave

Pilot size

Thread type

0=NPT1=RC2=G

0 1 2

Page 5: FLANGED VALVES - · PDF file1.Prepare inlet flanges and blowtube pipesouit t s valve specification. Avoidnstalling i valves underneath theank. t 2. Ensureank t and pipes are free

05

GOYEN RCAC25FS4

CONSTRUCTIONBody:Aluminium(diecast)

Screws: 304Stainlesssteel

Seals: Nitrile&EPDMorViton

Diaphragm:Proprietaryhigh-performanceengineeringthermoplasticElastomerorViton

OPERATIONRecommended on-time range: 50to500ms

Recommended time between pulses:1minuteorgreater

MAINTENANCEBeforeconductinganymaintenanceactivityonthesystemensurethatcomponentsarefullyisolatedfrompressureandpowersupplies.Pressureandpowershouldnotbereapplieduntilthevalvehasbeenfullyassembled.

Diaphragmandpilotunitinspectionshouldbeconductedannually.

APPROVALSTheRCAC25FS4meetstherequirementsoftheEuropeanLowVoltageDirective2006/95/EC,whenfittedwiththeRCA3PVpilot.

REVERSEPULSEJETVALVES

Please Note:WerecommendusingSchedule40pipe.ThicknessODisasshownbelow.

SIZE OD mm OD inches

1˝ 33.4 1.315

WEIGHTS

VALVE kg (lb)

RCAC25FS4 0.85(1.87)

MAINTENANCE KITS

MODEL SHOCKWAVE VITON

Diaphragm KitRCAC25FS4 K2546 K2551

FS Outlet SealRCAC25FS4 G690763 G690763-2

PRODUCT CHARACTERISTICS AND PERFORMANCE

NOMINAL PORT SIZE mm (in.)

NO. OF DIAPH.

FLOW KV (CV)

PRESSURE RANGE kPa (psi)

TEMPERATURE RANGE °C (°F)

SHOCKWAVE VITON

25(1) 1 34(40) 30(5)to860(125)

−40(−40)to82(179.6)

−29(−20.2)to232(449.6)

DESCRIPTIONHigh-performancediaphragmvalvewithaflangedinletportandslidesealoutletport.Equippedwith‘Shockwave’springlessdiaphragm.The4seriesvalvesareavailableasremotepilotvalvesandmaybeconvertedtointegralpilotusingeithertheRCA3DMorRCA3PVscrew-inpilots.Outletisat90°toinlet.TheFSvalverangefeaturesalargerdiameterinletprovidinghigherperformancethantheDDorTbodystyles.

SUITABLE FORDustcollectorapplications,inparticularforreversepulsejetfiltercleaninganditsvariations,includingbagfilters,cartridgefiltersandenvelopefilters,ceramicfiltersandsinteredmetalfibrefilters.

Examples:RCAC25FS40121˝FSvalvewith1 8˝RCpilotportthreads,Shockwavediaphragm.

Note:1 8PilotavailableinNPT,RCandGThread.¼PilotisonlyavailableinGThread.

ORDER CODE

0=1/8″1=1/4″

RCAC25FS4Diaphragm material

1=Viton2=Shockwave

Pilot size

Thread type

0=NPT1=RC2=G

0 1 2

DIMENSIONS(Dimensionsinmmand[inches])

Page 6: FLANGED VALVES - · PDF file1.Prepare inlet flanges and blowtube pipesouit t s valve specification. Avoidnstalling i valves underneath theank. t 2. Ensureank t and pipes are free

06

DIAPHRAGM SERVICE KITSFORDELETEDVALVES

MAINTENANCE KITS

MODEL NITRILE VITON LOW TEMPERATURE –60°C (–76°F) min.

INCLUDES

CA/RCA20FS K2000 K2007 NA

CA/RCA25FS K2501 K2503 K2504

Diaphragmkitsincludemainandsecondarydiaphragms(whererequired)andallsprings.

Page 7: FLANGED VALVES - · PDF file1.Prepare inlet flanges and blowtube pipesouit t s valve specification. Avoidnstalling i valves underneath theank. t 2. Ensureank t and pipes are free

CLEANAIRSYSTEMS.COM

©2014PentairCleanAirSystemsreservestherighttochangeproductdesignsandspecificationswithoutnotice.

Goy

enF

lang

edV

alve

sR

ev02

11/

14