Fisher Scientific MaximaDry ® Vacuum Pump Rugged Diaphragm Vacuum Pumps, Oil-Free, Low Maintenance, Reliable Operation Oil-free, low maintenance. No more downtime to add or change pump oil. Consider a MaximaDry pump for quiet, reliable operation without the mess of pump oil, or the operating costs and environmental problems associated with water aspirators. Corrosion resistant materials. Why worry about pump damage? The thick, solid PTFE resin heads will not peel or corrode when exposed to most aggressive solvents. The sturdy FFPM valve system handles occasional liquids without degrading performance. Quick and easy setup. You are up and running in minutes because everything connects together without tools or fittings. All that is necessary is 3/8” ID tubing. Compact, stylish design. For convenient access, your MaximaDry oil-free pump fits easily where you need it...on your bench or inside your fume hood. With its clean, modern appearance and quiet operation, you won’t want to hide it under your bench. Designed and built with the highest grade, corrosion-resistant materials available, these pumps will withstand even the most aggressive gases and vapors without the risk of damaging the pump.* The smooth, single-piece diaphragm is coated with premium PTFE. Our exclusive, high-flow valves, made of tough FFPM elastomer, enable the pump to handle liquid condensate without loss of performance. In addition, the ball-bearing, totally- enclosed fan-cooled (TEFC) motor is rated for continuous duty and never needs lubrication. By selecting a MaximaDry pump, you are freeing yourself from the hassle of stocking, checking, changing and disposing of hazardous pump oil. Even occasional diaphragm replacement takes only a few minutes, on-site, using simple tools, saving valuable equipment down time. With advantages like these, what are you waiting for? Start saving time and order one today.

Fisher Scientific MaximaDry Vacuum Pumpbeta-static.fishersci.com/content/dam/fishersci/en_US/documents/programs/...13-880-18 Two Stage 20 6 15 15 x 6.5 x 8.5 21 1/6 $1,766.33 13-880-20

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Fisher Scientific MaximaDry Vacuum Pumpbeta-static.fishersci.com/content/dam/fishersci/en_US/documents/programs/...13-880-18 Two Stage 20 6 15 15 x 6.5 x 8.5 21 1/6 $1,766.33 13-880-20

Fisher Scientific MaximaDry® Vacuum PumpRugged Diaphragm Vacuum Pumps, Oil-Free, Low Maintenance, Reliable Operation

Oil-free, low maintenance. No more downtime to add or change pump oil. Consider a MaximaDry pump for quiet, reliable operation without the mess of pump oil, or the operating costs and environmental problems associated with water aspirators.

Corrosion resistant materials. Why worry about pump damage? The thick, solid PTFE resin heads will not peel or corrode when exposed to most aggressive solvents. The sturdy FFPM valve system handles occasional liquids without degrading performance.

Quick and easy setup. You are up and running in minutes because everything connects together without tools or fittings. All that is necessary is 3/8” ID tubing.

Compact, stylish design. For convenient access, your MaximaDry oil-free pump fits easily where you need it...on your bench or inside your fume hood. With its clean, modern appearance and quiet operation, you won’t want to hide it under your bench.

Designed and built with the highest grade, corrosion-resistant materials available, these pumps will withstand even the most aggressive gases and vapors without the risk of damaging the pump.*

The smooth, single-piece diaphragm is coated with premium PTFE. Our exclusive, high-flow valves, made of tough FFPM elastomer, enable the pump to handle liquid condensate without loss of performance. In addition, the ball-bearing, totally-enclosed fan-cooled (TEFC) motor is rated for continuous duty and never needs lubrication.

By selecting a MaximaDry pump, you are freeing yourself from the hassle of stocking, checking, changing and disposing of hazardous pump oil. Even occasional diaphragm replacement takes only a few minutes, on-site, using simple tools, saving valuable equipment down time.

With advantages like these, what are you waiting for? Start saving time and order one today.

Page 2: Fisher Scientific MaximaDry Vacuum Pumpbeta-static.fishersci.com/content/dam/fishersci/en_US/documents/programs/...13-880-18 Two Stage 20 6 15 15 x 6.5 x 8.5 21 1/6 $1,766.33 13-880-20

115V/60Hz Cat No.

Head Configuration

Cap L/min.

Vacuum Torr

Pressure psig

DimensionsL x W x H in.

ShippingWt. lbs.

Motor HP

Price Each

13-880-14 Single Stage 20 75 15 13 x 6.5 x 8.5 21 1/6 $1,422.29

13-880-16 Single Stage 40 65 15 15 x 6.5 x 8.5 21 1/6 $1,853.13

13-880-18 Two Stage 20 6 15 15 x 6.5 x 8.5 21 1/6 $1,766.33

13-880-20 Two Stage 35 6 15 16 x 7 x 9 27 1/3 $2,378.03

13-880-22 Two Stage 35 1.5 15 16 x 7 x 9 27 1/3 $3,513.49

For rotary evaporation and distillation of high boiling point solvents, choose from these MaximaDry two stage pumps.

13-880-22 35 1.5

13-880-20 35 6

MaximaDry Application Guide Cat No. Cap. L/min

Vacuum Torr

For rotary evaporation and distillation of medium boiling point solvents, choose from these MaximaDry two stage pumps.

13-880-20 35 6

13-880-18 20 6

For rotary evaporation and distillation of low boiling point solvents, choose from these MaximaDry single stage pumps.

13-880-14 20 75

13-880-16 40 65

For filtration, blotting, solid phase extraction, choose from these MaximaDry single stage pumps.

13-880-14 20 75

13-880-16 40 65

For gel drying, choose from these MaximaDry two stage pumps. Use of a trap is advised.

13-880-20 35 6

13-880-18 20 6

For vacuum concentration, choose from these MaximaDry two stage pumps. Use of a trap is advised.

13-880-22 35 1.5

13-880-20 35 6

For small vacuum ovens with < 0.5 cu.ft.chamber capacity, choose from these MaximaDry two stage pumps. Use of a trap is advised.

13-880-20 35 6

13-880-18 20 6

For vacuum ovens with > 0.5 cu.ft. chamber capacity; choose from these MaximaDry two stage pumps. Use of a trap is advised.

13-880-22 35 1.5

13-880-20 35 6

*You should always check corrosion resistance charts for compatibility with the chemicals used in your laboratory. Specifications are subject to change without notice. You should consider the boiling point of the solvent in use and the volume of solvent to be distilled when selecting a pump.

MaximaDry Vacuum Pump Specifications and Ordering Information

BN0324111