    2 3PRODUCT DIMENSIONS CABINETRY DIMENSIONS

    N

    BC

    E

    D

    F

    J

    G

    H

    MI

    Installation diagrams for illustration purposes only

    K

    L

    AMG

    C

    I

    Product dimensions(inches (mm))Prefnished

    LCD

    DD24D

    Prefnished

    Flatdoor

    DD24D

    Integrated

    DD24D

    A overall height* o product 2 - 4 58(.- .)

    2 - 4 58(.- .)

    2 - 4 58(.- .)

    B overall width o product 2 916() 2 916() 2 916()

    C overall depth o product(excl. curvature/handle) 22 716 (0) 22 716 (0) 22 716 (0)

    D depth o drawer(open) (excl. curvature/handle) 2 316 () 2 316 () 2 316 ()

    E height* o chassis 78 (0) 78 (0) 78 (0)

    F height range o levelling eet 2 38 (0) 2 38 (0) 2 38 (0)

    G depth o chassis (incl. trimseal) 2 (2) 2 (2) 2 (2)

    H depth o drawer ront panel (excl. curvature/handle) 16 () 16 () 16 ()

    I depth o curvature or handle 716 () 58 (4) n/a

    J depth o toekick 2 - 4 516 (0 - 0) 2 - 4 516 (0 - 0) 2 58 - ( - 2)**

    K height o upper drawer ront (4) 16 () 16 () min

    L height o lower drawer ront 4 () 4 () 2 (.) min

    M height o installation bracket slots(on top o chassis) 16 (2) 16 (2) 16 (2)

    N height o drawer ronts 2 916 () 0 16 (4) 2 (.) min

    * Chassis heights include bracket slots

    ** less the Toekick Panel thickness (Minimum Panel thickness using the supplied screws is 38( mm)).

    Note: or Prefnished Flat door models, height rom top o handle to top o drawer - 2 (4 mm).

    Cabinetry dimensions(inches (mm))Prefnishe

    d

    LC

    D

    DD24

    D

    Prefnishe

    d

    Flatdoor

    DD24

    D

    Integrate

    d

    DD24

    D

    A inside height o cavity2 516 - 4

    (20- 2.)

    2 516 - 4 (20- 2.)

    2 516 - 4 (20- 2.)

    B inside width o cavity 2 58 (00) 2 58 (00) 2 58 (00)

    C inside depth o cavity(inside) 22 78 (0) 22 78 (0) 22 78 (0)

    D height o adjacent cabinetry 0 (2) 0 (2) min. 2 38 (20)

    E height o toekick space 516 - 516 (00-0) 516 - 516 (00-0) 516 - 516 (00-0)

    Minimum clearances(inches (mm))

    8 (2. mm)

    8 (

    2. mm)

    A

    B

    C

    D

    E

    Installation diagrams for illustration purposes only

    ( mm)

    (1,2) -1- 599618C DD24D install A2 USCA.indd 15/4/09 10:01:39 AM(1,2) -1- 599618C DD24D install A2 USCA.indd 15/4/09 10:01:39 AM

  • 8/2/2019 Fisher Paykel Dishwasher Install

    3/8

    PARTS SUPPLIED

    Clamp (1)Wire clip (2) Phillips16 mmscrews (9)

    Drain hosesupport (1)

    Moisture protectiontape (1)(to prevent moisturedamage)

    Drain hosejoiner (1)

    Topmountingbrackets (2)

    Prefinished toekick (1)white or black

    Washer (1) Edge protector (1)(if services holepartition i s metal)

    Hexagonalsocket (2)(long & short)

    4

    2 x 4

    If the Drain hose(s) supplied are not long enough to reach your services, you must use a Drain Hose Extension Kit P/N 525798 which will extend the drain hose(s) by 11 10 (3.6 m). The kit is available from the nearest

    Fisher & Paykel Authorized Service Agent, or Toll free 1.888.936.7872 or www.fisherpaykel.com.

    Important!Be sure the edges of the services hole are smooth or covered. If the services

    hole is through a metal partition the hole must be protected with the Edge

    protector supplied to prevent damage to the power cord or hoses.

    These marks indicate mounting bracket screw locations

    Preferred position. If adequate clearance, services hole can be

    higher to clear toekick space.

    If hole is higher, ensure drain hose(s) are routed straight into thewaste connection.

    Water Connection

    Recommended HOT (Maximum 140F/60C).

    Supplied hose to suit / (9 mm) male compression fitting.

    *

    110-120 VAC

    max. 15 A

    Note:Servic

    escanbelo

    cated

    eithersideo

    fDishDrawe

    r.

    max. ( mm)

    * *

    min. 78

    (200 mm)

    38(10 mm)

    max. 16(450 mm)

    If no side partition, use abrace for securing.

    Moistureprotectiontape mustbe applied.

    CAVITY PREPARATION5

    Water Pressure Max Min Water softener models 1 MPa (145 psi) 0.1 MPa (14.5 psi) Other models 1 MPa (145 psi) 0.0 MPa (4. psi)

    Drains will need to be separated to satisfy kosher requirements. We suggest you confirm

    acceptability with your local rabbi in respect to kosher installations.

    Max. distance of

    hoses and cord from

    chassis edge

    Left hand

    side

    Right hand

    side

    Drain hose 78 (2000 mm)

    70 (1800 mm)

    Inlet hose 64 (1650 mm)

    49(1250 mm)

    Power cord(excl. plug) 29 (750 mm)

    27 (700 mm)

    Left hand

    side

    Right hand

    side

    Water supply

    (2,1) -1- 599618C DD24D install A2 USCA.indd 15/4/09 10:01:39 AM(2,1) -1- 599618C DD24D install A2 USCA.indd 15/4/09 10:01:39 AM

  • 8/2/2019 Fisher Paykel Dishwasher Install

    4/8

    30 mm

    3

    2

    1

    4

    5

    6

    7

    7

    8

    8

    13

    17

    14

    15

    15

    16

    912

    11

    11

    10

    A

    Ensure the drawer is removedand then rotated counter-clockwise to prevent kinkedhoses.

    Access cover

    Remove theaccess cover

    Before refitting the drawer,ensure the hoses are nottwisted and the latches atthe rear of each drawerrunner are facing forward.

    Ensure the drawer clips onboth sides are reset.

    Ensure the draweris now rotatedclockwise back.

    Remove knock-out for cableclamp. Fit suitable cable clampfor the conduit and terminatethe wiring as shown.

    Use copperconductors only.

    78(150 mm)

    C D

    Remove Power supply

    B

    OPTIONALLY HARD WIRING THE PRODUCT6

    (2,2) -1- 599618C DD24D install A2 USCA.indd 15/4/09 10:01:39 AM(2,2) -1- 599618C DD24D install A2 USCA.indd 15/4/09 10:01:39 AM

  • 8/2/2019 Fisher Paykel Dishwasher Install

    5/8

    x 4

    1 2 34

    5

    1

    2

    Tie together to avoid kinking.

    Ensure product is level and aligning with cabinetry. Using themost appropriate length Hexagonal socket supplied, fully extendlevelling feet up to required distance by hand.

    Hexagonal socket

    A A

    B

    ROUTE THE HOSES AND MOVE INTO THE CAVITY7

    REMOVE THE DRAWER AND LEVEL THE PRODUCT8

    2

    1

    13

    3

    optionaloptional(x2)

    Ensure hoses and cordare not kinked or twisted.

    B

    30 mm

    1

    2

    3

    4

    5

    5

    5

    (150 mm)

    Ensure the drawer is removed andthen rotated counter-clockwiseto prevent kinked hoses.

    78(150 mm)

    A

    OR Loosen feet only andtake care when pushingthe product into thecavity that you do notbend the feet.

    If top mounting brackets are beingused, ensure theyre securely fittedbefore sliding product into cavity.

    (1,1) -2- 599618C DD24D install A2 USCA.indd 15/4/09 10:02:23 AM(1,1) -2- 599618C DD24D install A2 USCA.indd 15/4/09 10:02:23 AM

    (1 2) 2 599618C DD24D i t ll A2 USCA i dd 15/4/09 10 02 23 AM(1 2) 2 599618C DD24D i t ll A2 USCA i dd 15/4/09 10 02 23 AM

  • 8/2/2019 Fisher Paykel Dishwasher Install

    6/8

    1

    2

    4

    5

    4

    3B

    A

    C C

    BB

    A

    1

    2

    3

    A

    optional

    max. ( mm)

    4 5 6 7

    8 9

    10

    19

    Important!D o not overtighten screw.

    SECURE THE PRODUCT AND REFIT THE DRAWER9

    A

    B

    FIT THE TOEKICK10

    Before refitting the drawer,ensure the hoses are nottwisted and the latches atthe rear of each drawerrunner are facing forward.

    Ensure the drawer clips onboth sides are reset.

    Ensure the drawer isnow rotatedclockwise back.

    B

    The product has threepairs of mountingbrackets: a pair ofoptional bracketson the top (C) andtwo pairs of formedbrackets in the side of

    the chassis (A,B). Useat least two out of thethree pairs to securethe product.

    Ensure the soundinsulation isrepositionedcorrectly.

    Where the toekickmeets the bottomof the tub is thecut-off point

    (1,2) -2- 599618C DD24D install A2 USCA.indd 15/4/09 10:02:23 AM(1,2) -2- 599618C DD24D install A2 USCA.indd 15/4/09 10:02:23 AM

    (2 1) 2 599618C DD24D install A2 USCA indd 15/4/09 10:02:23 AM(2 1) 2 599618C DD24D install A2 USCA indd 15/4/09 10:02:23 AM

  • 8/2/2019 Fisher Paykel Dishwasher Install

    7/8

    PLUMBING AND DRAINAGE OPTIONS11

    29 - 34

    (750 -

    882.5 mm)

    1 (38 mm)

    1

    max. 4

    (120 mm)

    21

    6

    5

    4

    7

    2

    29 - 34

    (750 -882.5 mm)

    1

    3

    6

    5

    4

    5

    6

    5

    4

    5

    A

    If space is limited for fixing, pushhose through drain hose supportto required height

    DishDrawer with Waste Disposal

    29

    -34

    (750-882.5mm)

    min. R (200 mm)

    Supplied drain hose joiner( (19 mm)) waste tee)

    HIGHLOOPmin. 6(150 mm)

    DishDrawer using Air Breakwith Drain Hose Joiner

    Supplied drain hose joiner( (19 mm)) waste tee)

    Air Break

    7 38 (950 mm)

    Max. height totop of Air Break(countertop orwall mounted)

    Fit suppliedwasher

    Ensure hoses are routedstraight to joiner. Removeexcess hose material ifnecessary.

    DishDrawer and Standpipe 1 1/2 (38 mm)

    29-

    34

    (750-882.5mm)

    min. R (200 mm)

    Waste Disposal

    (optional)

    B

    Fit suppliedwasher

    10o 10o 10o

    Ensure hoses are routedstraight to joiner. Removeexcess hose material ifnecessary.

    Fit suppliedwasher

    C

    If space is limited for fixing, pushhose through drain hose supportto required height

    (2,1) -2- 599618C DD24D install A2 USCA.indd 15/4/09 10:02:23 AM(2,1) -2- 599618C DD24D install A2 USCA.indd 15/4/09 10:02:23 AM

  • 8/2/2019 Fisher Paykel Dishwasher Install

    8/8