CONNECT NEW TO EXISTING # REFERENCE DRAWING NUMBER * ISOMETRIC OR ELEVATION LETTER ISOMETRIC OR ELEVATION BUBBLE # REFERENCE DRAWING NUMBER * SECTION OR ELEVATION LETTER SECTION OR ELEVATION BUBBLE REVISION NUMBER REFERENCE BUBBLE # SHEET NUMBER * SECTION NUMBER DRAWING NOTE DEMOLITION NOTE 75 PSIG NOT TO SCALE 1 1. INFORMATION OBTAINED FROM ARVADA WATER DEPT. ON 07-08-2016. STATIC PRESSURE RESIDUAL PRESSURE FLOW GPM 90 PSIG 1,500 GPM FIRE PROTECTION WATER SUPPLY FIRE DEPARTMENT CONNECTION SPRINKLER SYSTEM PIPING STAND PIPE SYSTEM PIPING COMBINATION SPRINKLER/STANDPIPE PIPING DRAIN PIPING FLOW SWITCH ISOLATION VALVE W/ TAMPER SWITCH ANGLE VALVE PRESSURE GAUGE REDUCER BALL VALVE CHECK VALVE SIAMESE SIDEWALL SPRINKLER UPRIGHT SPRINKLER PENDANT SPRINKLER EXISTING FIRE SPRINKLER NEW FIRE SPRINKLER NEW FIRE SPRINKLER RELOCATED TO NEW LOCATION FIRE SPRINKLER TO BE REMOVED AND REPLACED IN THE SAME LOCATION ROOF MANIFOLD ALL SYMBOLS MAY NOT BE USED DESCRIPTION SYMBOL HORN AND STROBE SPRINKLER BRANCHLINE STAINLESS STEEL BRAIDED SPRINKLER DROP ADJUSTABLE HUB CEILING TILE SPRINKLER HEAD SUSPENDED T-BAR GRID MULTI-PORT CEILING GRID MOUNTING BRACKET FIRE SPRINKLER SERVICE ENTRY DETAIL (EXISTING) PIPE SADDLE SUPPORT (TYP.) (E) CAP (E) FLOW SWITCH (TYP.) (E) 2" ANGLE MAIN DRAIN VALVE (TYP.) (E) MANIFOLD MAIN DRAINS & EXTEND TO FLOOR SINK TO FDC (E) FBFP TO ZONE #1 TO ZONE #2 TO ZONE #3 (E) BUTTERFLY VALVE W/ INTEGRAL TAMPER SWITCH (TYP.) FINISHED GRADE (E) ROD AND SLEEVE PER NFPA 5'-0" FEBCO FEBCO FLOW TEST DATA FIRE SPRINKLER GENERAL NOTES 1. FIELD VERIFY BUILDING CONDITIONS PRIOR TO COMMENCING DESIGN RELATED WORK. 2. COORDINATE FIRE SPRINKLER SYSTEM INSTALLATION WITH OTHER TRADES AND BUILDING COMPONENTS PRIOR TO COMMENCING FABRICATION; RELOCATE SPRINKLER SYSTEM COMPONENTS FOUND TO BE IN CONFLICT WITH OTHER BUILDING SYSTEMS. 3. INSTALL SPRINKLER SYSTEM COMPONENTS AND PIPING TO ALLOW FOR ACCESS TO CEILING CAVITY AND TO OTHER SYSTEMS EQUIPMENT MOUNTED ABOVE CEILING. 4. PROVIDE ADDITIONAL OR MODIFY EXISTING SIGNAGE, LABELING AND IDENTIFICATION AS REQUIRED BY NFPA AND LOCAL JURISDICTIONAL AUTHORITY. 5. DESIGN AND INSTALLATION OF THE FIRE SPRINKLER SYSTEM SHALL COMPLY WITH ALL APPLICABLE NFPA AND LOCAL JURISDICTIONAL REQUIREMENTS, REVISE SPRINKLER SYSTEM INSTALLATION FOR FULL COMPLIANCE AS REQUIRED AT NO ADDITIONAL COST TO THE OWNER. 6. DRAIN AND TEST OUTLET CONNECTIONS SHALL BE DISCHARGED TO THE BUILDING EXTERIOR OR TO A PROPERLY SIZED RECEPTOR WITHIN THE BUILDING; DRAIN AND TEST OUTLET LOCATIONS SHALL BE IDENTIFIED ON SHOP DRAWINGS FOR REVIEW AND APPROVAL. 7. COORDINATE ALL ELECTRICAL AND FIRE ALARM CONNECTIONS WITH EC PRIOR TO INSTALLATION. 8. REFER TO PROJECT MANUAL FOR SPRINKLER TYPES AND INSTALLATION REQUIREMENTS. 9. THE FIRE SPRINKLER SYSTEM INFORMATION CONTAINED ON THE PLANS IS PROVIDED AS A GUIDE FOR THE FIRE SPRINKLER SYSTEM DESIGNER/INSTALLER AND IS NOT INTENDED TO SHOW ALL REQUIRED SYSTEM COMPONENTS; IT SHALL BE THE FIRE SPRINKLER SYSTEM DESIGNER/INSTALLERS RESPONSIBILITY TO PROVIDE A COMPLETE, APPROVED AND OPERATIONAL FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA AND THE LOCAL JURISDICTIONAL REQUIREMENTS. 10. COORDINATE INSTALLATION LOCATION OF ALL EXPOSED SPRINKLER SYSTEM PIPING WITH ARCHITECT AND GENERAL CONTRACTOR PRIOR TO INSTALLATION. 11. ALL WORK SHALL COMPLY WITH THE LATEST EDITION OF NFPA 13. 12. REFER TO PROJECT MANUAL FOR OCCUPANCY HAZARD CLASSIFICATIONS. ALL AREAS OF THE BUILDING SHALL BE CONSIDERED LIGHT HAZARD OCCUPANCY UNLESS REQUIRED OTHERWISE BY NFPA OR LOCAL JURISDICTIONAL FIRE AUTHORITY. DESCRIPTION SYMBOL GENERAL # * # # * # * F FDC SP ST SP/ST D E N R D FIRE PROTECTION LEGEND 2 FLEXIBLE FIRE SPRINKLER HEAD DETAIL NOT TO SCALE REFER TO PLUMBING PLANS (E)ST (E)SP (E)SP (E)SP 1 1 1 1 (E) FBFP (E)B-1 B-2 (E)GWH-1 (E)GWH-2 E.E E.F E.2 E.3 E.4 (E)FDC DRAWING NOTES # 1. ADD SIGNAGE FOR ZONE ARRANGEMENT AT EXISTING FIRE RISERS. ENVISION MECHANICAL ENGINEERS INC. 9777 Pyramid Court, Suite 120 Englewood, CO 80112 Tel- 303-688-0223 Fax- 303-688-3584 envisionengrs.com Project # Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF MOA ARCHITECTURE NOT FOR C ONSTRUCTION ADDITIONS AND RENOVATIONS 016-009 7/29/2016 10:38:09 AM FP-001 FIRE PROTECTION LEGENDS & SCHEDULES SIERRA ELEMENTARY SCHOOL JJR 08.04.16 16100.00 7771 Oak St. Arvada, CO 80005 BID SET JCF 1/4" = 1'-0" ENLARGED FIRE PROTECTION PLAN - BOILER ROOM 1 PLAN NORTH REVISION DATE

FIRE PROTECTION LEGEND - Himmelman · PDF filesprinkler system piping ... all symbols may not be used ... coordinate fire sprinkler system installation with other trades

  • Upload
    lamcong

  • View
    243

  • Download
    3

Embed Size (px)

Citation preview

CONNECT NEW TO EXISTING

# REFERENCE DRAWING NUMBER

* ISOMETRIC OR ELEVATION LETTER

ISOMETRIC OR ELEVATION BUBBLE

# REFERENCE DRAWING NUMBER

* SECTION OR ELEVATION LETTER

SECTION OR ELEVATION BUBBLE

REVISION NUMBER

REFERENCE BUBBLE # SHEET NUMBER * SECTION NUMBER

DRAWING NOTE

DEMOLITION NOTE

75 PSIG

NOT TO SCALE1

1. INFORMATION OBTAINED FROM ARVADA WATER DEPT. ON 07-08-2016.

STATIC PRESSURE RESIDUAL PRESSURE FLOW GPM

90 PSIG 1,500 GPM

FIRE PROTECTION WATER SUPPLY

FIRE DEPARTMENT CONNECTION

SPRINKLER SYSTEM PIPING

STAND PIPE SYSTEM PIPING

COMBINATION SPRINKLER/STANDPIPE PIPING

DRAIN PIPING

FLOW SWITCH

ISOLATION VALVE W/ TAMPER SWITCH

ANGLE VALVE

PRESSURE GAUGE

REDUCER

BALL VALVE

CHECK VALVE

SIAMESE

SIDEWALL SPRINKLER

UPRIGHT SPRINKLER

PENDANT SPRINKLER

EXISTING FIRE SPRINKLER

NEW FIRE SPRINKLER

NEW FIRE SPRINKLER RELOCATED TO NEW LOCATION

FIRE SPRINKLER TO BE REMOVED AND REPLACED IN THESAME LOCATION

ROOF MANIFOLD

ALL SYMBOLS MAY NOT BE USED

DESCRIPTIONSYMBOL

HORN AND STROBE

SPRINKLERBRANCHLINE

STAINLESS STEEL BRAIDEDSPRINKLER DROP

ADJUSTABLE HUB

CEILING TILE

SPRINKLER HEAD

SUSPENDED T-BAR GRID

MULTI-PORT CEILINGGRID MOUNTING

BRACKET

FIRE SPRINKLER SERVICE ENTRY DETAIL (EXISTING)

PIPE SADDLESUPPORT (TYP.)

(E) CAP

(E) FLOW SWITCH (TYP.)

(E) 2" ANGLE MAINDRAIN VALVE (TYP.)

(E) MANIFOLD MAINDRAINS & EXTEND TOFLOOR SINK

TO FDC

(E) FBFP

TO Z

ON

E #

1

TO Z

ON

E #

2

TO Z

ON

E #

3

(E) BUTTERFLY VALVE W/INTEGRAL TAMPERSWITCH (TYP.)

FINISHED GRADE

(E) ROD AND SLEEVEPER NFPA

5'-0"

FEBCO

FEBCO

FLOW TEST DATA

FIRE SPRINKLER GENERAL NOTES1. FIELD VERIFY BUILDING CONDITIONS PRIOR TO COMMENCING DESIGN

RELATED WORK.

2. COORDINATE FIRE SPRINKLER SYSTEM INSTALLATION WITH OTHER TRADES

AND BUILDING COMPONENTS PRIOR TO COMMENCING FABRICATION;

RELOCATE SPRINKLER SYSTEM COMPONENTS FOUND TO BE IN CONFLICT

WITH OTHER BUILDING SYSTEMS.

3. INSTALL SPRINKLER SYSTEM COMPONENTS AND PIPING TO ALLOW FOR

ACCESS TO CEILING CAVITY AND TO OTHER SYSTEMS EQUIPMENT MOUNTED

ABOVE CEILING.

4. PROVIDE ADDITIONAL OR MODIFY EXISTING SIGNAGE, LABELING AND

IDENTIFICATION AS REQUIRED BY NFPA AND LOCAL JURISDICTIONAL

AUTHORITY.

5. DESIGN AND INSTALLATION OF THE FIRE SPRINKLER SYSTEM SHALL COMPLY

WITH ALL APPLICABLE NFPA AND LOCAL JURISDICTIONAL REQUIREMENTS,

REVISE SPRINKLER SYSTEM INSTALLATION FOR FULL COMPLIANCE AS

REQUIRED AT NO ADDITIONAL COST TO THE OWNER.

6. DRAIN AND TEST OUTLET CONNECTIONS SHALL BE DISCHARGED TO THE

BUILDING EXTERIOR OR TO A PROPERLY SIZED RECEPTOR WITHIN THE

BUILDING; DRAIN AND TEST OUTLET LOCATIONS SHALL BE IDENTIFIED ON

SHOP DRAWINGS FOR REVIEW AND APPROVAL.

7. COORDINATE ALL ELECTRICAL AND FIRE ALARM CONNECTIONS WITH EC

PRIOR TO INSTALLATION.

8. REFER TO PROJECT MANUAL FOR SPRINKLER TYPES AND INSTALLATION

REQUIREMENTS.

9. THE FIRE SPRINKLER SYSTEM INFORMATION CONTAINED ON THE PLANS IS

PROVIDED AS A GUIDE FOR THE FIRE SPRINKLER SYSTEM

DESIGNER/INSTALLER AND IS NOT INTENDED TO SHOW ALL REQUIRED

SYSTEM COMPONENTS; IT SHALL BE THE FIRE SPRINKLER SYSTEM

DESIGNER/INSTALLERS RESPONSIBILITY TO PROVIDE A COMPLETE,

APPROVED AND OPERATIONAL FIRE SPRINKLER SYSTEM IN ACCORDANCE

WITH NFPA AND THE LOCAL JURISDICTIONAL REQUIREMENTS.

10. COORDINATE INSTALLATION LOCATION OF ALL EXPOSED SPRINKLER SYSTEM

PIPING WITH ARCHITECT AND GENERAL CONTRACTOR PRIOR TO

INSTALLATION.

11. ALL WORK SHALL COMPLY WITH THE LATEST EDITION OF NFPA 13.

12. REFER TO PROJECT MANUAL FOR OCCUPANCY HAZARD CLASSIFICATIONS.

ALL AREAS OF THE BUILDING SHALL BE CONSIDERED LIGHT HAZARD

OCCUPANCY UNLESS REQUIRED OTHERWISE BY NFPA OR LOCAL

JURISDICTIONAL FIRE AUTHORITY.

DESCRIPTIONSYMBOL

GENERAL

#*

#

#*

#*

F

FDC

SP

ST

SP/ST

D

E

N

R

D

FIRE PROTECTION LEGEND

2 FLEXIBLE FIRE SPRINKLER HEAD DETAILNOT TO SCALE

REFER TOPLUMBING

PLANS

(E)S

T

(E)S

P

(E)S

P

(E)S

P

1

1

1

1

(E)FBFP

(E)B-1B-2

(E)GWH-1

(E)GWH-2

E.E E.F

E.2

E.3

E.4

(E)F

DC

DRAWING NOTES #

1. ADD SIGNAGE FOR ZONE ARRANGEMENT AT EXISTING FIRE RISERS.

ENVIS

ION

MEC

HA

NIC

AL

EN

GIN

EER

S I

NC

.

9777 P

yramid

Court, S

uit

e 1

20

Engle

wood, C

O 8

0112

Tel-

303-6

88-0

223

Fax- 303-6

88-3

584

envis

ionengrs.c

om

Proje

ct #

Date

Drawn By

Checked By:

Project Number

Sheet Name

Copyright:

ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE

DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF

MOA ARCHITECTURE

NOT FOR

CONSTRUCTION

AD

DIT

ION

S A

ND

RE

NO

VA

TIO

NS

016-0

09

7/29

/201

6 10

:38:

09 A

M

FP-001

FIRE PROTECTIONLEGENDS &SCHEDULES

SIE

RR

A E

LE

ME

NT

AR

Y S

CH

OO

L

JJR

08.04.16

16100.00

7771

Oak

St.

Arv

ada,

CO

800

05

BID SET

JCF

1/4" = 1'-0"

ENLARGED FIRE PROTECTION PLAN - BOILER ROOM1

PLAN NORTH

REVISION DATE

lmedina
Ellipse

1

FP-001

1 2 3 4

6

5

89 10

12

13

A

B

C

E

G

K

L

J

M

D

F

H

6.5

E.AE.B E.C E.D E.EE.FE.G E.H E.J

E.1

E.2

E.3E.4

E.5

E.6

E.7

E.8

E.9

E.10

7

SP

4

3

2

SP

SP

SPSP

(E) FDC

4

5

FDC

SPSP

SP

1

6

8

10

9

10

9

9

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

1 2 3

89 10

12

A

B

C

E

G

K

L

J

M

D

F

H

6

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

SP

DRAWING NOTES #

1. FIRE SPRINKLER ZONE 2. EXTEND FIRE SPRINKLER PIPING THIS FLOOR.

2. FIRE SPRINKLER PIPING DOWN INTO ELEVATOR SHAFT, PROVIDE SIDEWALL SPRINKLERAT ELEVATOR PIT PER NFPA.

3. CONNECT TO EXISTING FIRE SPRINKLER PIPING STUBS ABOVE CEILING AND EXTEND TOZONES INDICATED.

4. MODIFY EXISTING FIRE SPRINKLER TO ACCOMMODATE NEW CEILING PER NFPA 13.

5. PROVIDE ISOLATION VALVE WITH TAMPER SWITCH AND FLOW SWITCH FOR ELEVATOR FIRE SPRINKLER, COORDINATE WITH FIRE ALARM SYSTEM INSTALLER FOR REQUIRED ALARM CONNECTION.

6. PROVIDE UPRIGHT SPRINKLERS WITH WIRE GUARDS IN ELECTRICAL ROOMS, COORDINATESPRINKLER PIPE ROUTING AND SPRINKLER LOCATIONS WITH E.C. PRIOR TO INSTALLATION.

7. FIRE SPRINKLER ZONE 3 MAIN UP TO FLOOR ABOVE, SEE PLAN AT LEFT FOR CONTINUATION.

8. PROVIDE INTERMEDIATE TEMPERATURE SPRINKLERS AT KILN ROOM, COORDINATE LOCATION OF SPRINKLERS WITH KILN AND ASSOCIATED HOOD LOCATIONS PRIOR TO INSTALLATION.

9. PROVIDE SPRINKLER COVERAGE BELOW EXPOSED STAIR, PROVIDE WIRE GUARDS WHERESPRINKLERS ARE LOCATED 8'-0" OR LESS ABOVE FINISHED FLOOR.

10. PROVIDE UPRIGHT SPRINKLERS WITH WIRE GUARDS IN STORAGE AREAS.

ENVIS

ION

MEC

HA

NIC

AL

EN

GIN

EER

S I

NC

.

9777 P

yramid

Court, S

uit

e 1

20

Engle

wood, C

O 8

0112

Tel-

303-6

88-0

223

Fax- 303-6

88-3

584

envis

ionengrs.c

om

Proje

ct #

Date

Drawn By

Checked By:

Project Number

Sheet Name

Copyright:

ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE

DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF

MOA ARCHITECTURE

NOT FOR

CONSTRUCTION

AD

DIT

ION

S A

ND

RE

NO

VA

TIO

NS

016-0

09

7/29

/201

6 10

:38:

14 A

M

FP-101

FIRE PROTECTIONPLANS

SIE

RR

A E

LE

ME

NT

AR

Y S

CH

OO

L

JJR

08.04.16

16100.00

7771

Oak

St.

Arv

ada,

CO

800

05

BID SET

JCF

PLAN NORTH

AREA 'A'EXISTINGBUILDING

AREA 'B'

AREA 'C'

KEYPLANPLA

N N

OR

TH

PLAN NORTH

1" = 20'-0"

01.Fire Protection Level 1 - Overall1 1" = 20'-0"

02.Fire Protection Level 2 - Overall2

REVISION DATE

lmedina
Ellipse

F

P

PLUMBING LEGENDALL SYMBOLS MAY NOT BE USED

DESCRIPTIONSYMBOL

PLUMBING GENERAL NOTES

DESCRIPTIONSYMBOL

GENERAL

STORM DRAIN, RAINWATER DRAINSD

OVERFLOW STORM DRAINOD

SUBSOIL DRAIN, FOOTING DRAINSSDSOIL, WASTE, OR SANITARY SEWERSAN

STORM / RAINWATER DRAIN BELOW FLOORSD

SOIL / WASTE / SANITARY SEWER BELOW FLRSAN

GREASE DRAINGDVENT

ACID WASTEAW

ACID VENTAV

INDIRECT DRAINDPUMP DISCHARGE LINEPD

COLD WATER

HOT WATER SUPPLY (140° F)

HOT WATER RECIRCULATING (140° F)TEMPERED HOT WATER (110° F)TW

TEMPERED HW RECIRCULATING (110° F)TWR

(CHILLED) DRINKING WATER SUPPLYDWS

(CHILLED) DRINKING WATER RECIRCULATINGDWRSOFT WATERSW

CONDENSATE DRAINCD

DISTILLED DRAINDI

DEIONIZED WATERDELAWN SPRINKLER SUPPLYLS

FIRE PROTECTION WATER SUPPLYF

GAS, LOW-PRESSUREG

GAS, MEDIUM-PRESSUREMGGAS, HIGH-PRESSUREHG

GAS VENTGV

FUEL OIL SUPPLYFOS

FUEL OIL RETURNFORFUEL OIL VENTFOV

LUBRICATING OILLO

LUBRICATING OIL VENTLOV

WASTE OILWOWASTE OIL VENTWOV

OXYGENOX

LIQUID OXYGENLOX

COMPRESSED AIRAMEDICAL COMPRESSED AIRMA

LABORATORY COMPRESSED AIRLA

VACUUMV

MEDICAL VACUUMMVSURGICAL VACUUMSV

LABORATORY VACUUMLV

NITROGENN

NITROUS OXIDENO²CARBON DIOXIDECO²

WET VACUUM CLEANINGWVC

DRY VACUUM CLEANINGDVC

ISOLATION VALVE

GLOBE VALVE

ANGLE VALVE

BALL VALVE

BUTTERFLY VALVE

GAS COCK, GAS STOP

COMBINATION FLOW MEASURINGDEVICE AND BALANCING VALVE

CHECK VALVE

PLUG VALVE

SOLENOID VALVE

S

MOTOR-OPERATED VALVE [SPECIFY TYPE]

M

PRESSURE REDUCING VALVE

PRESSURE-RELIEF VALVEP

TEMPERATURE-PRESSURE-RELIEF VALVET

HOSE BIBB

VALVE IN YARD BOX (VALVE TYPE SYMBOLAS REQUIRED FOR VALVE USE)

RECESSED-BOX HOSE BIBB ORWALL HYDRANT

UNION (SCREWED)

UNION (FLANGED)

STRAINER

PIPE ANCHOR

PIPE GUIDE

EXPANSION JOINT

FLEXIBLE CONNECTOR

TEE

CONCENTRIC REDUCER

ECCENTRIC REDUCER

AQUASTAT

FLOW SWITCH

PRESSURE SWITCH

WATER HAMMER ARRESTER

PRESSURE GAUGE WITH GAUGE COCK

THERMOMETER

VALVE IN RISERRISER DOWN (ELBOW)

RISER UP (ELBOW)

AIR CHAMBER

RISE OR DROP

BRANCH-TOP CONNECTION

BRANCH-BOTTOM CONNECTION

BRANCH-SIDE CONNECTION

CAP ON END OF PIPE

CLEANOUT PLUG

CIRCULATION PUMP

FLOOR CLEANOUT

WALL CLEANOUT

YARD CLEANOUT OR CLEANOUT TO GRADE

FLOOR DRAIN

FLOOR SINK

CONDUCTOR NOZZLE

DIRECTION OF FLOW

INDICATES PIPE SLOPE DOWN

NEW TO EXISTING CONNECTION

INDICATES ITEMS TO BE REMOVED

GAS TURRET

NOTE:

1. COORDINATE AND SCHEDULE WITH GAS SERVICE AND METER PROVIDER PRIOR TO COMMENCING WORK. LOW PRESSURE GAS (14" W.C.) REQUIRED

FROM THE METER TO THE BUILDING. CONTACT THE BUILDER CALL LINE PRIOR TO COMMENCING WORK.

2. GAS PIPE SIZING BASED UPON 200 LINEAR FEET OF GAS PIPING, LOW PRESSURE GAS (14"W.C.) AT 831 BTU/CF.

CONNECTED GAS LOAD SCHEDULE

1 (E)GWH-1 300,000 300,000 7"W.C. MECHANICAL ROOM EXISTING

6,435,000TOTAL CONNECTED LOAD

NO OF UNITS EQUIPMENT LOAD EACH (BTU/H) TOTAL LOADPRESSURE REQUIRED

MIN. / MAX.LOCATION REMARKS

1 (E)GWH-2 400,000 400,000 7"W.C. MECHANICAL ROOM

1 (E)B-1 2,000,000 2,000,000 7"W.C. MECHANICAL ROOM

1 (E)MAU-1 300,000 300,000 7"W.C. ROOF

1 (E)MAU-2 305,000 305,000 7"W.C. ROOF

EXISTING

EXISTING

EXISTING

EXISTING

1 B-2 3,000,000 3,000,000 7"W.C. MECHANICAL ROOM ADDED

1 MAU-3 130,000 130,000 7"W.C. ROOF ADDED

NOTES:

1. REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL INSULATION REQUIREMENTS.

2. (ASTM E84) ALL INSULATION MATERIALS INSTALLED WITHIN THE PLENUM SHALL MEET THE FLAME/SMOKE REQUIREMENTS OF 25/50.

REMARKS:

1. FOR PIPING SMALLER THAT 1-1/2" INSTALLED WITHIN A BUILDING PARTITION WITHIN A CONDITIONED SPACE WITHIN A CONDITIONED SPACE. INSULATION

REDUCTION OF UP TO 1" BUT NOT LESS THAN 1" PER IECC TABLE C403.2.1, NOTE A.

DOMESTIC

COLD WATER

DOMESTIC

COLD WATER

DOMESTIC

HOT WATER & RECIRC.

DOMESTIC

HOT WATER & RECIRC.

STORM & OVERFLOW

DRAINAGE

ROOF & OVERFLOW

DRAIN BOWLS

INTERIOR

INTERIOR

(WITHIN PARTITION)

INTERIOR

INTERIOR

(WITHIN PARTITION)

INTERIOR

GLASS FIBER

WITH ASJ-SSL

GLASS FIBER

WITH ASJ-SSL

GLASS FIBER

WITH ASJ-SSL

GLASS FIBER

WITH ASJ-SSL

GLASS FIBER

GLASS FIBER

YES

YES

NONE

NONE

YES

YES

NONE

NONE

NONE

NONE

PVC

NONE

40 - 60

120 - 140

NA

NA

0.21 - 0.27 75

0.21 - 0.27 75

0.21 - 0.28 100

0.21 - 0.28 100

0.21 - 0.27 75

0.21 - 0.27 75

0.5 1 1 1 -

0.5 1 1 1 1

1 1.5 1.5 1.5 -

1 1.5 1.5 1.5 1

1 1 1 1 -

1 1 1 1 -

0.5

0.5

1

1

1

1INTERIOR

40 - 60

120 - 140

SERVICE

INSULATION CONDUCTIVITY

CONDUCTIVITY BTU * IN / (H * FT * °F )

LOCATIONINSULATION

MATERIAL

VAPOR

BARRIERJACKET

OPERATING

TEMPERATURE( ° F )

MEAN TEMP RATING ( ° F )

NOMINAL PIPE SIZE (IN)REMARKS

< 1 1 TO < 1-1/2 1-1/2 TO < 4 4 TO < 8 ≤ 8

PIPE INSULATION SCHEDULE

1. ALL INFORMATION SHOWN ON THESE DRAWINGS INCLUDING

LOCATION AND SIZES ARE BASED ON THE BEST INFORMATION

AVAILABLE. INFORMATION SHOWN IS TO INDICATE THE INTENT OF

THE PLUMBING SYSTEM WORK BUT MAY NOT REFLECT THE

EXACT ROUTING AND LOCATION. IT IS THE RESPONSIBILITY OF

THE CONTRACTOR TO FIELD VERIFY EXISTING EQUIPMENT,

PIPING, CONNECTIONS, STRUCTURE, ELECTRICAL, LIGHTING AND

ARCHITECTURAL INFLUENCES PRIOR TO INSTALLATION OF THE

NEW WORK TO AVOID ANY CONFLICTS WITH SYSTEMS

REQUIRING MODIFICATIONS. NOTIFY ENGINEER OF ANY

CONFLICTS, PRIOR TO PERFORMING WORK.

2. OFFSET ALL PIPING AS REQUIRED TO AVOID STRUCTURAL

MEMBERS, FLASHING, MECHANICAL AND ELECTRICAL EQUIPMENT.

3. DO NOT SCALE DRAWINGS, SEE ARCHITECTURAL DRAWINGS FOR

FINAL LOCATIONS OF ALL PLUMBING FIXTURES, GENERAL

PURPOSE FLOOR DRAINS, AND ADDITIONAL EQUIPMENT

REQUIRING PLUMBING CONNECTIONS.

4. COORDINATE SANITARY DRAINAGE UTILITY LOCATIONS AND

INVERT ELEVATIONS PRIOR TO COMMENCING WORK, NOTIFY

ARCHITECT IMMEDIATELY IF CONDITIONS DISCOVERED WILL NOT

ALLOW SYSTEM INSTALLATION AS DESIGNED.

5. SEE ISOMETRICS AND DIAGRAMS FOR BRANCH PIPE SIZES NOT

INDICATED IN PLAN.

6. COORDINATE PLACEMENT OF SLEEVES THROUGH FLOORS,

WALLS AND ROOF CONSTRUCTION PRIOR TO COMMENCING

WORK.

7. SEE ARCHITECTURAL PLANS AND DETAILS FOR MOUNTING

ELEVATIONS OF ALL PLUMBING FIXTURES.

8. MOUNT WALL HYDRANTS AND HOSE BIBBS AT 18" ABOVE

SURROUNDING GRADE OR FINISHED FLOOR ELEVATIONS UNLESS

SPECIFICALLY NOTED OTHERWISE.

9. FIELD VERIFY EXACT LOCATION OF ALL EXISTING UTILITIES AND

EQUIPMENT PRIOR TO COMMENCING WORK.

10. PROTECT EXISTING UTILITIES AND EQUIPMENT TO REMAIN

DURING ENTIRE CONSTRUCTION PERIOD; REPLACE DAMAGED

MATERIALS IMMEDIATELY AT NO ADDITIONAL COST TO THE

OWNER.

11. COORDINATE EXACT ROUGH-IN CONNECTION LOCATIONS AND

SIZES WITH EQUIPMENT SUPPLIER PRIOR TO COMMENCING

WORK ASSOCIATED WITH EQUIPMENT BEING FURNISHED BY

OTHERS.

12. SEE HVAC PLANS FOR FINAL LOCATION OF ALL HVAC EQUIPMENT,

COORDINATE PIPING SYSTEM CONNECTION PRIOR TO

INSTALLATION.

13. ALL WORK SHALL COMPLY WITH IPC 2015 AND IFGC 2015.

14. ALL MATERIALS IN THE PLENUM SPACE SHALL MEET THE FLAME

SPREAD AND SMOKE DEVELOPMENT INDEX PER

IMC/2015-SECTION 602.2.1. AND SHALL BE LISTED AND LABELED

FOR INSTALLATION WITHIN A PLENUM.

15. ALL EQUIPMENT AND MATERIALS USED IN THE DISTRIBUTION OF

DOMESTIC POTABLE WATER SHALL BE APPROVED AND TESTED

FOR SUCH APPLICATION WITH DOCUMENTED LISTINGS AND

LABELING IN ACCORDANCE WITH THE LATEST EDITION OF THE

INTERNATIONAL PLUMBING CODE, PUBLIC LAW 111-380 AND

ANSI/NSF-61, ANNEX G.

16. EXTEND ALL VENT TERMINATIONS THROUGH THE ROOF A

MINIMUM OF 20' FROM ALL OUTSIDE AIR INTAKES, AND OTHER

BUILDING OPENINGS.

CONNECT NEW TO EXISTING

REFERENCE BUBBLE

REVISION NUMBER

SECTION OR ELEVATION BUBBLE

DRAWING NOTE

DEMOLITION NOTE

* SECTION NUMBER# SHEET NUMBER#

*

#

#*

* SECTION OR ELEVATION LETTER

*#

ISOMETRIC OR ELEVATION BUBBLE

# REFERENCE DRAWING NUMBER

* ISOMETRIC OR ELEVATION LETTER# REFERENCE DRAWING NUMBER

#

#

DEMOLITION NOTE, ALTERNATEX

DRAWING NOTE, ALTERNATE#

ABOVEABV

AMERICANS WITH DISABILITIES ACTA.D.A.ABOVE FINISHED FLOORAFF

ABOVE FINISHED GRADEAFG

ACID NEUTRALIZATION TANKANT

ACCESS PANELAPARCHITECT, ARCHITECTURALARCH

ACID VENT THROUGH ROOFAVTR

BACK FLOW PREVENTERBFP

BELOWBLWBALL VALVEBV

COMMONC

CUBIC FEET PER HOURCFH

CAST IRON PIPINGC.I.CEILINGCLG

COLUMNCOL

CONCRETECONC

CONNECTCONNCONTINUECONT

CONSTRUCT, CONSTRUCTIONCONST

COORDINATECOOR

CRAWLSPACECSCHECK VALVECV

DOWNDN

DISHWASHERDW

EXISTING(E)EACHEA

ELECTRICAL CONTRACTOREC

ELECTRIC, ELECTRICALELEC

ELEVATIONELEVELECTRIC WATER COOLEREWC

FAHRENHEITF

FLOORFLR

GENERAL CONTRACTORGC

GALLONS PER MINUTEGPM

HEADERHDR

HORIZONTALHORIZHORSEPOWERHP

INVERT ELEVATIONIE

INDIRECT WASTEIW

INTEGRALINTJOIST(S)JST(S)

KITCHEN EQUIPMENT CONTRACTORKEC

LOCATIONLOC

MANUFACTUREMANUFMAXIMUMMAX

THOUSAND BRITISH THERMAL UNIT PER HOURMBH

MECHANICAL CONTRACTORMC

MEDIUM PRESSURE GASMGMINIMUMMIN

MEMORY STOPMS

NEW(N)

NORMALLY CLOSEDNCNORMALLY OPEN / NUMBERNO

NOT TO SCALENTS

OUTSIDE AIROA

PLUMBING CONTRACTORPCPHASEPH

POINT OF CONNECTIONP.O.C.

PROVIDEPROV

PRESSURE REDUCING VALVEPRVPRESSURE PER SQUARE INCH GAUGEPSIG

PRESSURE AND TEMPERATURE RELIEFPTR

POLYVINYL CHLORIDE PIPINGPVC

RELOCATED(R)RETURN AIRRA

REFERENCERE

REQUIREDREQD

SUPPLY AIRSASANITARY PIPINGSAN

SHEETSHT

SQUARESQ

SIMILARSIMSAFETY RELIEF VALVESRV

STAINLESS STEELSS

TEMPERATURE CONTROLTCC

TYPICALTYPVENT PIPINGV

VERTICALVERT

VACUUM BREAKERVB

VENT THROUGH ROOFVTRWITHW

DESCRIPTIONSYMBOL

PLUMBING ABBREVIATIONS

FIELD VERIFYFV

ENVIS

ION

MEC

HA

NIC

AL

EN

GIN

EER

S I

NC

.

9777 P

yramid

Court, S

uit

e 1

20

Engle

wood, C

O 8

0112

Tel-

303-6

88-0

223

Fax- 303-6

88-3

584

envis

ionengrs.c

om

Proje

ct #

Date

Drawn By

Checked By:

Project Number

Sheet Name

Copyright:

ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE

DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF

MOA ARCHITECTURE

NOT FOR

CONSTRUCTION

AD

DIT

ION

S A

ND

RE

NO

VA

TIO

NS

016-0

09

7/29

/201

6 10

:38:

15 A

M

P-001

PLUMBING CODESHEET

SIE

RR

A E

LE

ME

NT

AR

Y S

CH

OO

L

JJR

08.04.16

16100.00

7771

Oak

St.

Arv

ada,

CO

800

05

BID SET

JCF

REVISION DATE

lmedina
Ellipse

SYMMONS S-6080

LK-35ELKAYDRAIN STRAINER

1,31/2" 1/2"2"2"1-1/2"LRAD-1919

CHICAGOELKAY

FAUCET1-COMPT. CR SINK

S-1

1,21/2"--2"2"1 1/4"0355.012

0700J.R. SMITH

AM. STD.

SUPPORT CARRIERFAUCET

WALL HUNG LAVATORYL-2

HWCWCWVWREMARKS

TRAP

ROUGH-IN CONNECTIONSMODEL NOMANUFACTURERTAG DESCRIPTION

8

L-1 1 1/4" 2" 2" -- 1/2" 2

--1"2"2"INT.TUE1LN12CP0637

UT447E

J.R. SMITHTOTOTOTO

CARRIERFLUSH VALVEUR-1

WALL HUNG URINAL

S-22-COMPARTMENT SINK

FAUCETELKAY

CHICAGO 1-1/2" 2" 2" 1/2"1/2" 4

1/2"1-1/4" 2" 2" -- 1EWC-1J.R. SMITH

ELKAY VRCGRNTL8C0830

LRAD-3319

ELECTRIC WATER COOLERSUPPORT CARRIER

1/2" 1/2" -3" 3"FIAT

CHICAGOMSB-2424MOP SERVICE BASIN

MSB-1FAUCET

2"

1,8--1"2"2"INT.TUE1LN12CPUT447E

TOTOTOTO

CARRIERFLUSH VALVEUR-2

WALL HUNG URINAL

WALL. MTD. WATER CLOSET TOTO CT708EWC-1 FLUSH VALVE

SEATINT. 2"4" --1"TOTO TET1LN32#CP 9

WALL. MTD. WATER CLOSET TOTO CT708ELWC-2 FLUSH VALVE

SEATINT. 2"4" --1"TOTO TET1LN32#CP 1,9

NOTES:

1. REFER TO ARCHITECTURAL DRAWINGS AND ELEVATIONS FOR EXACT LOCATION AND MOUNTING HEIGHT ELEVATIONS OF ALL PLUMBING FIXTURES PRIOR

TO INSTALLATION.

2. PROVIDE ALL FIXTURES WITH CHROME PLATED CAST BRASS, ADJUSTABLE 'P' TRAPS WITH CLEANOUT PLUGS, TUBING OUTLETS AND WALL FLANGES

UNLESS FIXTURE IS FURNISHED WITH AN INTEGRAL TRAP OR IS PROVIDED ONE AS A STANDARD ACCESSORY.

3. PROVIDE ALL FIXTURES WITH CHROME PLATED SUPPLIES WITH ANGLE OR STRAIGHT PATTERN LOOSE KEY 1/4 TURN STOPS UNLESS FIXTURE IS

FURNISHED WITH INTEGRAL STOPS OR STOPS ARE PROVIDED AS STANDARD ACCESSORIES.

4. ALL LAVATORIES AND SINKS DESIGNATED TO BE IN COMPLIANCE WITH ANSI-A117.1 SHALL BE PROVIDED WITH OFFSET TAILPIECE CONNECTIONS AND

PROTECTIVE TRAP AND SUPPLY WRAPPING KITS, REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

5. FURNISH ALL BATTERY POWERED FAUCETS AND FLUSH VALVES WITH NEW SET OF BATTERIES FOLLOWING FINAL ACCEPTANCE OF THE PROJECT,

COORDINATE WITH THE OWNER'S DESIGNATED REPRESENTATIVE.

6. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION WHICH MAY NOT BE NOTED HERE.

7. ALL EQUIPMENT AND MATERIALS USED IN THE DISTRIBUTION OF DOMESTIC POTABLE WATER SHALL BE APPROVED AND TESTED FOR SUCH APPLICATION

WITH DOCUMENTED LISTINGS AND LABELING IN ACCORDANCE WITH THE LATEST EDITION OF THE INTERNATIONAL PLUMBING CODE, PUBLIC LAW 111-380

AND ANSI/NSF-61, ANNEX G .

REMARKS:

445897SRCXKCP

CHURCH 9500SSC

CHURCH 9500SSC

0637J.R. SMITH

SYMMONS S-60800355.012

0700J.R. SMITH

AM. STD.

SUPPORT CARRIERFAUCET

WALL HUNG LAVATORY

LK-35ELKAYDRAIN STRAINER

1,51/2" 1/2"2"2"SI-1LFRAD-191816

CHICAGOELKAY

FAUCET1-COMPT. ART SINK

S-3

S-42-COMPARTMENT ART SINK

FAUCETELKAY

CHICAGO SI-1 2" 2" 1/2"1/2" 6LRAD-3321

1100-GN2AE35-317ABLK-35ELKAYDRAIN STRAINER

WC-3SEAT

INT. 2"4" --1" 1,7FLOOR. MTD. WATER CLOSET 2282.010AM. STD.

FLUSH VALVE TOTO TET1LN32#CPCHURCH 9500SSC

BRONZE FINISH WITH WALL FLANGE.

CAST IRON ADJUSTABLE CLEANOUT WITH ROUND

BRONZE TOP AND ABS PLUG.

6" Ø STRAINER W/ VANDAL RESISTANT SCREWS.

PROVIDE WITH TRAP GUARD.

GALVANIZED FLANGED HOUSING WITH HEAVY DUTY

COVER, VANDAL RESISTANT SCREWS.

NO-HUB BOTTOM OUTLET, PVC OVERFLOW STANDPIPE

WITH UNDER DECK CLAMP, CAST IRON DOME STRAINER

NO HUB BOTTOM OUTLET, UNDER DECK CLAMP, CAST

IRON DOME STRAINER.

STAINLESS STEEL SHALLOW COVER, ROUND FACE W/

VANDAL RESISTANT CENTER SCREW.

1/2" INLINE DUAL CHECK VALVE ASSEMBLY. NSF-61.

BOX TYPE, 1/2" INLET, POLISHED CHROME

ON FLOOR TYPE 2" INLET/OUTLET CONNECTIONS

REMOVABLE SEDIMENT BUCKET, ALLOW 9-1/2" ABOVE

UNIT FOR BASKET REMOVAL

BOX TYPE, 3/4" INLET, POLISHED CHROME

COMPLETE WITH SERVICE ISOLATION VALVE

COMPLETE WITH SERVICE ISOLATION VALVE

COMPLETE WITH SERVICE ISOLATION VALVE

COMPLETE WITH SERVICE ISOLATION VALVE

TAG DESCRIPTION MANUFACTURER MODEL NO REMARKS

BFP-1 BACKFLOW PREVENTER FEBCO 510

CN-1 CONDUCTOR NOZZLE J.R. SMITH 1770

FCO-1 FLOOR CLEANOUT J.R. SMITH 4220

FD-1 FLOOR DRAIN (GENERAL) J.R. SMITH 2005Y

GCO-1 GRADE CLEANOUT J.R. SMITH 4880-U

HB-1 HOSE BIBB WOODFORD B75

OD-1 OVERFLOW ROOF DRAIN J.R. SMITH 1070Y-C-CID

SI-1 PLASTER TRAP ZURN Z1181-E-SS

RD-1 ROOF DRAIN J.R. SMITH 1010Y-C-CID

WCO-1 WALL CLEANOUT J.R. SMITH 4710-U

WH-1 WALL HYDRANT WOODFORD B67

WHA-1 WATER HAMMER ARRESTOR PPP SC-500A

WHA-2 WATER HAMMER ARRESTOR PPP SC-750B

WHA-3 WATER HAMMER ARRESTOR PPP SC-1000C

WHA-4 WATER HAMMER ARRESTOR PPP SC-1250D

BARRIER TRAP SEAL GUARD (ASSE 1072). PROVIDE SIZE

AS REQUIRED.

2" = 2692-02

3" = 2692-03

4" = 2692-04

TG-1 TRAP GUARD J.R. SMITH

WATER MIXING VALVE SCHEDULE

SYMBOL SERVICE MANUF. MODEL NUMBERINLETSIZE

OUTLETSIZE

INLETTEMPERATURE ( ° F )

OUTLETTEMPERATURE

( ° F )

MINIMUM FLOWGPM

REMARKS

TMV-1 LAVS/SINK BRADLEY S59-3080-B 1" 1-1/4" 40 110 2.0 1.2,3140

CW HW

REMARKS:

1. SURFACE MOUNTED, PROVIDE COMPLETE WITH WALL MOUNTING BRACKET; LEAD FREE DESIGN, INLET STRAINER CHECKSTOPS, INTEGRAL DIAL

THERMOMETER.

2. MINIMUM FLOW OF 0.5 GOM WITH OPERATIONAL CIRCULATION.

3. SINK AND LAVATORY TO MEET ASSE 1070.

PLUMBING EQUIPMENT SCHEDULE PLUMBING FIXTURE SCHEDULE

DOMESTIC WATER CIRCULATION PUMP SCHEDULE

MODEL NUMBERMANUF.SYMBOL REMARKS

CP-1 B&G NBF-25 1

REMARKS:

1. WATER TEMP 110F.

INLETSIZE

OUTLETSIZE

FLOW RATE

10.5 GPM3/4"3/4"

HEAD

10 FT.

WATTS RPM

2950125

ELECTRICALCHARACTER

115 VOLT / 1 PHASE

SERVICE

110F SERVICE

1. FIXTURE DESIGNATED TO BE IN COMPLIANCE WITH ANSI-A117.1.

2. WALL MOUNTED LAVATORY, BATTERY POWERED SENSOR FAUCET, 0.5 GPM, 4" CENTERS, PROVIDE WITH TMV-1.

3. STAINLESS STEEL SINGLE COMPARTMENT SINK, 6" DEEP. MANUAL FAUCET, 8" CENTERS, RIDGID GOOSENECK FAUCET, 2.2 GPM, WRISTBLADE HANDLES.

PROVIDE WITH TMV-1.

4. STAINLESS STEEL DOUBLE COMPARTMENT SINK, 6" DEEP, MANUAL FAUCET, 2.2 GPM, WRISTBLADE HANDLES. PROVIDE WITH TMV-1.

5. STAINLESS STEEL SINGLE COMPARTMENT SINK, 6" DEEP. TWO MANUAL FAUCETS, 8" CENTERS, RIDGID GOOSENECK FAUCET, 2.2 GPM, WRISTBLADE HANDLES.

PROVIDE WITH TMV-1.

6. 2 COMPARTMENT STAINLESS STEEL SINK, MANUAL FAUCET, 8" CENTERS, RIDGID GOOSENECK FAUCET, 2.2 GPM, WRISTBLADE HANDLES. PROVIDE WITH

TMV-1.

7. PRIMARY HEIGHT WATER CLOSET, BATTERY POWERED SENSOR FLUSH VALVE, 1.28 GPF.

8. BATTERY POWERED SENSOR FLUSH VALVE, 0.5GPF.

9. BATTERY POWERED SENSOR FLUSH VALVE, 1.28 GPF.

REMARKS:

1. CONTROLS CONTRACTOR TO CONNECT RELAY FOR PUMP TO DDC SYSTEM.

2. PROVIDE WITH OIL-MINDER CONTROL SYSTEM WITH VISUAL AND AUDIBLE ALARM. COORDINATE ALARM LOCATION WITH ARCHITECT.

SUMP PUMP SCHEDULE (ELEVATOR)

MODEL NUMBERMANUFACTURERSYMBOL REMARKS

ESP-1 STANCOR SE50 1, 2

OUTLET SIZE

2"

FLOW RATE

50 GPM

ELECTRICALCHARACTER

115V / 1 PHASE / 60 Hz

HEAD HP / WATTS

0.5 HP20 FT.

DRAIN STRAINER LK-35ELKAY

1100-G2E3-317AB

1100-GN2AE35-317AB

1100-GN2AE35-317AB

SIDE OUTLET, UNDER DECK CLAMP, CAST

IRON DOME STRAINER.RD-2 CANOPY DRAIN J.R. SMITH 1025-C-CID

12" Ø STRAINER W/ SLOTTED SEDIMENT BUCKET.

PROVIDE WITH TRAP GUARD.FD-2 FLOOR DRAIN (ART) J.R. SMITH 2240Y

VC-1 J.R. SMITHVENT CAP CAST IRON, VANDAL PROOF HOODED VENT CAP.1748

FS-1 FLOOR SINK (KITCHEN) J.R. SMITH12" SQ. 8" DEEP W/ ALUMINUM DOME BOTTOMSTRAINER AND 1/2 A.R.C. GRATE. PROVIDE WITHTRAP GUARD.

3430Y-PDBS-12

GDU-1 DISPOSER I.S.E. BADGER 5 120/1/60, 1/2 HP, 6.3 AMP., 1725 RPM

ENVIS

ION

MEC

HA

NIC

AL

EN

GIN

EER

S I

NC

.

9777 P

yramid

Court, S

uit

e 1

20

Engle

wood, C

O 8

0112

Tel-

303-6

88-0

223

Fax- 303-6

88-3

584

envis

ionengrs.c

om

Proje

ct #

Date

Drawn By

Checked By:

Project Number

Sheet Name

Copyright:

ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE

DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF

MOA ARCHITECTURE

NOT FOR

CONSTRUCTION

AD

DIT

ION

S A

ND

RE

NO

VA

TIO

NS

016-0

09

7/29

/201

6 10

:38:

15 A

M

P-002

PLUMBINGSCHEDULES

SIE

RR

A E

LE

ME

NT

AR

Y S

CH

OO

L

JJR

08.04.16

16100.00

7771

Oak

St.

Arv

ada,

CO

800

05

BID SET

JCF

REVISION DATE

lmedina
Ellipse

(E)GD (E)GD

(E)G

D

(E)G

D

(E)SAN

(E)S

AN

(E)S

AN

(E)SAN (E)SAN

(E)S

AN

(E)S

AN

(E)S

AN

I.E. =93'-6"

(E)SAN

I.E. =93'-8"

(E)SAN(E)SAN (E)SAN

RE: CIVIL FORCONTINUATION

(E)SAN

(E)S

AN

(E)S

AN

I.E. =92'-2"

I.E. =94'-6"I.E. =94'-8"

(E) 2500 GALLONGREASEINTERCEPTOR

(E)PD

(E)D

(E)S

AN

1

6

5

13

E

K

L

J

M

F

H

6.5

4"

4"

2"

2"

4"

4"

2"

4"

6" 6"6"6"6"

2"

4"

2"4"

3"

3"

4"

4" 4"

2"

2"

2"

4"

2"

6"

4"

6"

3"4"

4"

6"

6"

6"

2"2"

2"

2"

3"

2"

2"

3"

2"

4"

4

E.A E.B E.C E.D E.E E.F E.G E.H E.J

E.1

E.2

E.3

E.4

E.5

E.6

E.7

E.8

E.9

E.10

2

2

2

3

3

2

(E) G

(E) SP-1

PHASE 1B

6

5

13

E

K

L

J

M

F

H

6.5

E.A E.B E.C E.D E.E E.F E.G

E.H

E.J

E.1

E.2

E.3

E.4

E.5

E.6

E.7

E.8

E.9

E.10

DEMOLITION NOTES #

1. (E) 6" SAN STUBBED FOR FUTURE CONNECTION, FIELD VERIFY EXACT LOCATION AND DEPTH PRIOR TO COMMENCING WORK.

2. DEMOLISH EXISTING PERFORATED PERIMETER DRAIN.

3. TEMPORARY CAP EXISTING PERFORATED PERIMETER DRAIN FOR RECONNECTION. REFER TO SHEET P-100A FOR NEW WORK.

4. (E) 4" SAN STUBBED AND CAPPED FOR FUTURE CONNECTION, FIELD VERIFY EXACT LOCATION AND DEPTH BEFORE COMMENCING WORK.

ENVIS

ION

MEC

HA

NIC

AL

EN

GIN

EER

S I

NC

.

9777 P

yramid

Court, S

uit

e 1

20

Engle

wood, C

O 8

0112

Tel-

303-6

88-0

223

Fax- 303-6

88-3

584

envis

ionengrs.c

om

Proje

ct #

Date

Drawn By

Checked By:

Project Number

Sheet Name

Copyright:

ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE

DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF

MOA ARCHITECTURE

NOT FOR

CONSTRUCTION

AD

DIT

ION

S A

ND

RE

NO

VA

TIO

NS

016-0

09

7/29

/201

6 10

:38:

52 A

M

PD-100A

UNDERFLOORPLUMBING

DEMOLITION PLAN- AREA A -

PHASES 1A & 1B

SIE

RR

A E

LE

ME

NT

AR

Y S

CH

OO

L

JJR

08.04.16

16100.00

7771

Oak

St.

Arv

ada,

CO

800

05

BID SET

JCF

PLAN NORTHPLAN NORTH

AREA 'A'EXISTINGBUILDING

AREA 'B'

AREA 'C'

KEYPLAN 1/8" = 1'-0"

UNDERFLOOR PLUMBING DEMOLITION PLAN - AREA A1

REVISION DATE

lmedina
Ellipse

DN

(E)UR

(E)UR

(E)WC

(E)2"FD

(E)2"FD (E)2"FD

(E)2"FD

(E)DF

(E)WC

(E)WC (E)WC

(E)WC

(E)WC

(E)WC

(E)WC

(E)LAV(E)LAV

(E)LAV(E)LAV

(E)LAV(E)DF

(E)MSB

(E)LAV

(E)LAV

(E)WC

(E)WC

(E)2"FD

(E)2"FD

(E)SINK (E)WB

(E)SINK

(E)SINK

(E)SH(E)LAV(E)WC(E)2"FD

(E)2"FD

(E)LAV

(E)LAV

(E)DF

(E)SCO (E)SCO(E)SCO

(E)SCO

(E)SCO

(E) 2500 GALLONGREASEINTERCEPTOR

(E)WCO

(E)WCO

(D)SINK

(E)SINK

(E)SINK

(E)4"FCO

(E)3"VTR

(E)S

D

TO (E)6"RD

(E)3"VTR

(E)3"VTR

(E)OD(E)OD

(E)O

D

TO (E)4"ODTO (E)6"OD

(E)3"VTR

(E)SD TO (E)4"RD(E)SD

(E)S

D

TO (E)6"RD

(E)6"FCO

(E)SD

TO (E)4"RD TO (E)4"RD

(E)SD

TO (E)4"RD

TO (E)3"RD

(E)S

D

(E)S

D

(E)S

D

2 GPM

(E)3"VTR

1 GPM

(E)WB

(E)SH

E.A E.B E.C E.D E.E E.F E.G E.H E.J

E.1

E.2

E.3

E.4

E.5

E.6

E.7

E.8

E.9

E.10

3

2

KITCHENOFFICE

135A

COOLERS

135C

STORAGE &RECEIVING

136

UNISEX TOILET

135B

KITCHEN

135

STORAGE

106C

OUTDOORSTORAGE

107

CHAIRSTORAGE

106B

FACILITYMANAGER

OFFICE

101N

OFFICE

106A

MUSIC

105

PRINCIPAL

101A

CLOSET

101B

CLINIC

101L

UNISEX

101H

UNISEX

101M

STORAGE

101K

ASSIST.PRIN.

101G

RESOURCEROOM

101D

TEST

102A

TOILET

102B

MDF ROOM

143

CHALLENGE

102

STORAGE

102F

WORKROOM

102E

CORRIDOR

101J

CONFERENCE

102C

VESTIBULE

100

MECHANICAL

141

JAN.

139

VESTIBULE

142

ELECTRICAL

140STORAGE

134A

GIRLS

138

BOYS

137

CORRIDOR

103

TOILET

102D

RECEPTION

101

DRY STORAGE

135D

CORRIDOR

103A

CORRIDOR

103B

VESTIBULE

104

MULTI-PURPOSEGYMNASIUM

106

WORK ROOM

101E

PHASE 1B

1

DEMOLITION NOTES #

1. RE-CONFIGURE WATER SERVICE FOR IRRIGATION MODIFICATIONS. RE: 16/P-500.

2. DEMOLISH EXISTING SINK AND ALL ASSOCIATED PIPING AS SHOWN.

3. REMOVE AND HOLD EXISTING SINK AND ASSOCIATED ACCESSORIES FOR REINSTALLATIONDEMOLISH EXISTING ASSOCIATED PIPING AS SHOWN. REFER TO DRAWING P-101A FORE NEW WORK.

ENVIS

ION

MEC

HA

NIC

AL

EN

GIN

EER

S I

NC

.

9777 P

yramid

Court, S

uit

e 1

20

Engle

wood, C

O 8

0112

Tel-

303-6

88-0

223

Fax- 303-6

88-3

584

envis

ionengrs.c

om

Proje

ct #

Date

Drawn By

Checked By:

Project Number

Sheet Name

Copyright:

ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE

DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF

MOA ARCHITECTURE

NOT FOR

CONSTRUCTION

AD

DIT

ION

S A

ND

RE

NO

VA

TIO

NS

016-0

09

7/29

/201

6 10

:38:

54 A

M

PD-101A

FIRST FLOORPLUMBING

DEMOLITION PLAN- AREA A -

PHASES 1A & 1B

SIE

RR

A E

LE

ME

NT

AR

Y S

CH

OO

L

JJR

08.04.16

16100.00

7771

Oak

St.

Arv

ada,

CO

800

05

BID SET

JCF

PLAN NORTH

AREA 'A'EXISTINGBUILDING

AREA 'B'

AREA 'C'

KEYPLAN 1/8" = 1'-0"

FIRST FLOOR PLUMBING DEMOLITION PLAN - AREA A1

PLAN NORTH

REVISION DATE

lmedina
Ellipse

(E)GD (E)GD

(E)G

D

(E)G

D

(E)SAN

(E)S

AN

(E)S

AN

(E)SAN (E)SAN

(E)S

AN

(E)S

AN

(E)S

AN

I.E. =93'-6"

(E)SAN

(E)SAN(E)SAN (E)SAN

RE: CIVIL FORCONTINUATION

(E)SAN

(E)S

AN

(E)S

AN

I.E. =92'-2"

I.E. =94'-6"I.E. =94'-8"

(E) 2500 GALLONGREASEINTERCEPTOR

(E)PD

(E)D

(E)S

AN

TO (E) PERIMETER DRAIN

(E) WATER ENTRY,RE: CIVIL FOR

CONTINUATION

(E) FIRE SERVICEENTRY,

RE: CIVIL FORCONTINUATION

(E)3" (E)6"

6

5

13

E

K

L

J

M

F

H

6.5

3"

12

3

(E)SAN

E.A E.B E.C E.D E.E E.F E.G E.H E.J

E.1

E.2

E.3

E.4

E.5

E.6

E.7

E.8

E.9

E.10

RE

:

MA

TC

HLIN

E

MA

TC

HLIN

E

P-1

00

B

RE

:

MA

TC

HLIN

E

MA

TC

HLIN

E

P-1

00

B

2"

4

5GD

GD54 4

3"

3"

3"

77

7

3

2"

6

(E)4"

(E)2"

(E)4"

(E)2"

(E)6"

(E)6"

(E)3"

(E)4"

(E)6"

(E)4"

(E)4"

(E)4"

3"

3"

(E)4"

(E)6"

PHASE 1B

FINISHED FLOOR ELEVATION100'-0"

5643.30 USGS

FINISHED FLOOR ELEVATION100'-0"

5643.30 USGS

3" IRRIGATION. REFERTO CIVIL PLANS FORCONTINUATION.

CONNECT NEW 3"IRRIGATION TO (E) 3"IRRIGATION.

3"

3"

3"3"

DRAWING NOTES #

1. CONNECT 3" SANITARY LINE TO (E) 4" SANITARY LINE. FIELD VERIFY LOCATION AND ELEVATION.

2. 3" SANITARY UP TO FCO.

3. 2" SAN UP TO SINK ABOVE.

4. 3" GREASE DRAIN DOWN TO (E) GREASE DRAIN.

5. 3" GREASE DRAIN WITH P-TRAP UP TO FLOOR SINK.

6. CONNECT 2" SANITARY LINE TO (E) 2" SANITARY LINE.

7. 2" VENT RISE UP THRU FLOOR.

ENVIS

ION

MEC

HA

NIC

AL

EN

GIN

EER

S I

NC

.

9777 P

yramid

Court, S

uit

e 1

20

Engle

wood, C

O 8

0112

Tel-

303-6

88-0

223

Fax- 303-6

88-3

584

envis

ionengrs.c

om

Proje

ct #

Date

Drawn By

Checked By:

Project Number

Sheet Name

Copyright:

ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE

DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF

MOA ARCHITECTURE

NOT FOR

CONSTRUCTION

AD

DIT

ION

S A

ND

RE

NO

VA

TIO

NS

016-0

09

7/29

/201

6 10

:38:

17 A

M

P-100A

UNDERFLOORPLUMBING PLAN -AREA A - PHASES

1A & 1B

SIE

RR

A E

LE

ME

NT

AR

Y S

CH

OO

L

JJR

08.04.16

16100.00

7771

Oak

St.

Arv

ada,

CO

800

05

BID SET

JCF

PLAN NORTH

AREA 'A'EXISTINGBUILDING

AREA 'B'

AREA 'C'

KEYPLAN 1/8" = 1'-0"

UNDERFLOOR PLUMBING PLAN - AREA A1

PLAN NORTH

REVISION DATE

lmedina
Ellipse

I.E. =93'-8"(E)6"

11

SANSAN

SA

N

SAN

SA

N

1 2 3 4

6

5

8 9 10 1213

E

G

K

L

J

M

D

F

H

6.5

E.A E.B

E.1

E.2

E.3

E.4

E.5

E.6

E.7

E.8

E.9

RE

:

MA

TC

HLIN

E

MA

TC

HLIN

E

P-1

00

A

RE

:

MA

TC

HLIN

E

MA

TC

HLIN

E

P-1

00

A

RE

:

MA

TC

HLIN

E

MA

TC

HLIN

E

P-1

00C

RE:

MATCHLINE

MATCHLINE

P-100C

6"

I.E.=97'-10"(5,441 SQ.FT.)RE: CIVIL FORCONTINUATION

I.E.=96'-4"(4,012 SQ.FT.)RE: CIVIL FORCONTINUATION

SD

6"

SANSAN

2" 3"

SA

N

3"

3"

2"

2"

4"

SAN

2"

2" 4"

2"

4" 6" 6"

4"

2"2"

2" 2"

4"

4"

SA

N

8

6"

1

3"

1

SA

N

SAN

SA

N

3"

3"

3"

1

2"

3

5' - 0"

5 4

6

3

2

4

3

1111

11

11

5

3

2

2"4"

1

1

8

3

52

6

1

14 2 2

2

14

2

13

5

3 12 3

14

8"

SD

3"

SD

SD

9I.E.=96'-4"(10,255 SQ.FT.)RE: CIVIL FORCONTINUATION

5' - 0"

7

I.E.=97'-10"(106 SQ.FT.)RE: CIVIL FORCONTINUATION

7

3"

SD

2"

17

17

4"

4"

4"

4"

4"

6"

163"

5

4

4

2"2"

PIPE SLEEVETYPICAL

FINISHED FLOOR ELEVATION100'-0"

5643.30 USGS

FINISHED FLOOR ELEVATION100'-0"

5643.30 USGS

1/8" / 1'-0"1/8" / 1'-0"

1/4" / 1'-0"

1/8" / 1'-0"

1/8

" / 1'-0"

FINISHED FLOOR ELEVATION100'-0"

5643.30 USGS

1/8

" / 1'-0"

SA

N

1/8

" / 1'-0"

4

4

DRAWING NOTES #

1. 2" SAN UP TO SINK ABOVE.

2. 2" SAN UP TO LAV ABOVE.

3. 4" SAN UP TO WATER CLOSET ABOVE.

4. 2" SAN WITH P-TRAP UP TO FLOOR DRAIN ABOVE.

5. 2" VENT UP TO FLOOR ABOVE.

6. 4" SAN UP TO CLEANOUT ABOVE.

7. 3" SD DOWN FROM ABOVE.

8. 6" SD DOWN FROM ABOVE.

9. 8" SD DOWN FROM ABOVE.

10. 4" SD UP TO FCO.

11. CONNECT 6" SANITARY LINE TO (E) 6" SANITARY LINE. APPROX. I.E.= XXXX, FIELD VERIFYPRIOR TO COMMENCING WORK.

12. 2" SAN UP TO URINAL.

13. 3" SAN UP TO MOP BASIN.

14. 2" SAN UP THRU FLOOR.

15. 4" SAN UP THRU FLOOR.

16. 3" SAN UP TO FLOOR DRAIN ABOVE.

17. CONNECT NEW 4" SOLID WALL PERIMETER DRAIN PIPE TO EXISTING TEMPORARY CAPPED PERFORATED PERIMETER DRAIN. FIELD VERIFY EXACT LOCATION AND ELEVATION.

ENVIS

ION

MEC

HA

NIC

AL

EN

GIN

EER

S I

NC

.

9777 P

yramid

Court, S

uit

e 1

20

Engle

wood, C

O 8

0112

Tel-

303-6

88-0

223

Fax- 303-6

88-3

584

envis

ionengrs.c

om

Proje

ct #

Date

Drawn By

Checked By:

Project Number

Sheet Name

Copyright:

ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE

DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF

MOA ARCHITECTURE

NOT FOR

CONSTRUCTION

AD

DIT

ION

S A

ND

RE

NO

VA

TIO

NS

016-0

09

7/29

/201

6 10

:38:

18 A

M

P-100B

UNDERFLOORPLUMBING PLAN -AREA B - PHASE

1A

SIE

RR

A E

LE

ME

NT

AR

Y S

CH

OO

L

JJR

08.04.16

16100.00

7771

Oak

St.

Arv

ada,

CO

800

05

BID SET

JCF

PLAN NORTH

AREA 'A'EXISTINGBUILDING

AREA 'B'

AREA 'C'

KEYPLANPLAN NORTH

1/8" = 1'-0"

UNDERFLOOR PLUMBING PLAN - AREA B1

REVISION DATE

lmedina
Ellipse

SA

N

SA

N

1 2 3 4

8

910

12

A

B

C

E

G

D

SA

N

RE

:

MA

TC

HLIN

E

MA

TC

HLIN

E

P-1

00B

RE:

MATCHLINE

MATCHLINE

P-100B

I.E.=97'-6"(3,584 SQ.FT.)RE: CIVIL FORCONTINUATION

6"

SD

I.E.=96'-4"(2,931 SQ.FT.)RE: CIVIL FORCONTINUATION

I.E.=96'-4"(2,942 SQ.FT.)RE: CIVIL FORCONTINUATION

I.E.=96'-4"(1,284 SQ.FT.)RE: CIVIL FORCONTINUATION

I.E.=97'-2"(1,900 SQ.FT.)RE: CIVIL FORCONTINUATION

I.E.=96'-10"(893 SQ.FT.)RE: CIVIL FORCONTINUATION

SD

SD

SD

SD

SD

4"

3"

4"

6"

6"

2"

2"

2"3"

2"

2"

4"

2"

2"

2"

SANESP-1

5' - 0"

5' - 0"

5' - 0"

5' - 0"

5' - 0"

5' - 0"

1

12

8

8

1

1

8

7

9

7

1

1

6

1

1

112"

SAN

10

3

12

1

1

2"

2"

3"

1

2" 2"

SAN

SA

N

SA

N

SAN

SAN

SAN

SAN

4"

1/8

" / 1'-0"

1/8" / 1'-0"

1/8" / 1'-0"

1/8

" / 1'-0"

1/8

" / 1'-0"

1/8" / 1'-0"

4

FINISHED FLOOR ELEVATION100'-0"

5643.30 USGS

FINISHED FLOOR ELEVATION100'-0"

5643.30 USGS

5

1/8

" / 1'-0"

I.E.=5641.42'

I.E.=5640.15'

SA

N

1/8

" / 1'-0"

1/4" / 1'-0"

4

4

DRAWING NOTES #

1. 2" SAN UP TO SINK ABOVE.

2. 2" SAN UP TO LAV ABOVE.

3. 4" SAN UP TO WATER CLOSET ABOVE.

4. 2" SAN UP TO FLOOR DRAIN ABOVE.

5. 2" VENT UP TO FLOOR ABOVE.

6. 4" SAN UP TO CLEANOUT ABOVE.

7. 4" SD DOWN FROM ABOVE.

8. 6" SD DOWN FROM ABOVE.

9. 3" SD DOWN FROM ABOVE.

10. 4" SAN UP TO FLOOR ABOVE.

11. 2" SAN UP TO WATER COOLER.

12. 2" PUMPED DRAIN UP FROM ELEVATOR SUMP PUMP.

ENVIS

ION

MEC

HA

NIC

AL

EN

GIN

EER

S I

NC

.

9777 P

yramid

Court, S

uit

e 1

20

Engle

wood, C

O 8

0112

Tel-

303-6

88-0

223

Fax- 303-6

88-3

584

envis

ionengrs.c

om

Proje

ct #

Date

Drawn By

Checked By:

Project Number

Sheet Name

Copyright:

ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE

DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF

MOA ARCHITECTURE

NOT FOR

CONSTRUCTION

AD

DIT

ION

S A

ND

RE

NO

VA

TIO

NS

016-0

09

8/3/

2016

2:4

1:34

PM

P-100C

UNDERFLOORPLUMBING PLAN -AREA C - PHASE

1A

SIE

RR

A E

LE

ME

NT

AR

Y S

CH

OO

L

JJR

08.04.16

16100.00

7771

Oak

St.

Arv

ada,

CO

800

05

BID SET

JCF

PLAN NORTH

AREA 'A'EXISTINGBUILDING

AREA 'B'

AREA 'C'

KEYPLANPLAN NORTH

1/8" = 1'-0"1

UNDERFLOOR PLUMBING PLAN - AREA C

REVISION DATE

lmedina
Ellipse

DN

(E)UR

(E)UR

(E)WC

(E)2"FD

(E)2"FD (E)2"FD

(E)2"FD

(E)DF

(E)WC

(E)WC (E)WC

(E)WC

(E)WC

(E)WC

(E)WC

(E)LAV(E)LAV

(E)LAV(E)LAV

(E)LAV(E)DF

(E)MSB

(E)LAV

(E)LAV

(E)WC

(E)WC

(E)2"FD

(E)2"FD

(E)SINK (E)WB

(E)SINK

(E)SINK

(E)SH(E)LAV(E)WC(E)2"FD

(E)2"FD

(E)LAV

(E)LAV

(E)SCO (E)SCO(E)SCO

(E)SCO

(E)SCO

(E) 2500 GALLONGREASEINTERCEPTOR

(E)WCO

(E)WCO

(E)SINK

(E)4"FCO

P-140

1

(E)3"VTR

(E)S

D

TO (E)6"RD

(E)2"

(E)2"

(E)3"VTR

(E)3"VTR

(E)OD(E)OD

TO (E)4"ODTO (E)6"OD

(E)4"(E)6"

(E)SD TO (E)4"RD(E)SDTO (E)6"RD

(E)3"(E)2"(E)1"

(E)6"FCO

(E)SD

TO (E)4"RD TO (E)4"RD

(E)SD(E)4"(E)4"

(E)6"

TO (E)4"RD

TO (E)3"RD(E)3"

(E)4"

(E)4"(E)4"

(E)S

D

(E)S

D

(E)S

D

2 GPM(E)1"(E)2"(E)2 1/2"

CWHW

HWC

(E)H

WC

(E)H

W(E

)CW

HWCHW

CW

(E)2"(E)1"

(E)3/4"

(E)3/4"

(E)2"

(E)4"

(E)2 1/2"

(E)2"(E)1"

(E)3"VTR

1 GPM

(E)WB

(E)1"(E)3/4"(E)3/4"

(E)1"(E)1"(E)3/4"

(E)3/4"(E)3/4"(E)3/4"

(E)SH

CWHW

HWC

CW

HW

HW

C

(E)1 1/2"(E)1"

(E)3/4"

6

5

13

K

L

J

M

F

H

6.5

RE

:

MA

TC

HLIN

E

MA

TC

HLIN

E

P-1

01

B

RE

:

MA

TC

HLIN

E

MA

TC

HLIN

E

P-1

01

B

(E)G(E)G

TO (E)MAU-2 ABOVE

4"FCO

1

1/2"

3/4"3/4"

1/2"

2

E.A E.B E.C E.D E.E E.F E.G E.H E.J

E.1

E.2

E.3

E.4

E.5

E.6

E.7

E.8

E.9

E.10

G

1 1/4"

1/2"1/2"

2"3

(R)SINK

PHASE 1B

WAITING

101F

OFFICE

101E

KITCHENOFFICE

135A

COOLERS

135C

STORAGE &RECEIVING

136

UNISEX TOILET

135B

KITCHEN

135

STORAGE

106C

OUTDOORSTORAGE

107

CHAIRSTORAGE

106B

FACILITYMANAGER

OFFICE

101N

OFFICE

106A

MUSIC

105

PRINCIPAL

101A

CLOSET

101B

CLINIC

101L

UNISEX

101H

UNISEX

101M

STORAGE

101K

ASSIST.PRIN.

101G

RESOURCEROOM

101D

TEST

102A

TOILET

102B

MDF ROOM

143

CHALLENGE

102

STORAGE

102F

WORKROOM

102E

CORRIDOR

101J

CONFERENCE

102C

VESTIBULE

100

MECHANICAL

141

JAN.

139

VESTIBULE

142

ELECTRICAL

140STORAGE

134A

GIRLS

138

BOYS

137

CORRIDOR

103

TOILET

102D

RECEPTION

101

DRY STORAGE

135D

CORRIDOR

103A

CORRIDOR

103B

VESTIBULE

104

MULTI-PURPOSEGYMNASIUM

106

DRAWING NOTES #

1. CONNECT 1/2" CW, 3/4" HW & HWC TO EXISTING LINES AND RUN TO SINK AT LOCATION SHOWN.

2. 2" VENT UP TO STRUCTURAL SPACE, THEN TRANSITION TO 3" VTR IN VERTICAL STRUCTURALSPACE.

3. 2" VENT, 1/2" CW AND 1/2" HW DOWN TO SINK.

ENVIS

ION

MEC

HA

NIC

AL

EN

GIN

EER

S I

NC

.

9777 P

yramid

Court, S

uit

e 1

20

Engle

wood, C

O 8

0112

Tel-

303-6

88-0

223

Fax- 303-6

88-3

584

envis

ionengrs.c

om

Proje

ct #

Date

Drawn By

Checked By:

Project Number

Sheet Name

Copyright:

ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE

DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF

MOA ARCHITECTURE

NOT FOR

CONSTRUCTION

AD

DIT

ION

S A

ND

RE

NO

VA

TIO

NS

016-0

09

7/29

/201

6 10

:38:

22 A

M

P-101A

FIRST FLOORPLUMBING PLAN -AREA A - PHASES

1A & 1B

SIE

RR

A E

LE

ME

NT

AR

Y S

CH

OO

L

JJR

08.04.16

16100.00

7771

Oak

St.

Arv

ada,

CO

800

05

BID SET

JCF

PLAN NORTH

AREA 'A'EXISTINGBUILDING

AREA 'B'

AREA 'C'

KEYPLAN 1/8" = 1'-0"

FIRST FLOOR PLUMBING PLAN - AREA A1

PLAN NORTH

REVISION DATE

lmedina
Ellipse

F.E

.C.

F.E.C.

F.E

.C.

(E)S

D

4"FCO

2 1/2"2"

3/4"

4

S-1

P-140

3

S-1S-1S-1

S-1S-1

S-1S-1

WC-3L-1

2 1/2"

WC-3

L-1S-1

S-1

S-1

P-140

2

2"

2 1/2"

3/4"

1 2 3 4

6

5

8 9 10 1213

E

G

K

L

J

M

D

F

H

6.5

RE

:

MA

TC

HLIN

E

MA

TC

HLIN

E

P-1

01

A

RE

:

MA

TC

HLIN

E

MA

TC

HLIN

E

P-1

01

A

RE

:

MA

TC

HLIN

E

MA

TC

HLIN

E

P-1

01C

RE:

MATCHLINE

MATCHLINE

P-101C

2

P-142

4" FCO-1

E.A E.B

E.1

E.2

E.3

E.4

E.5

E.6

E.7

E.8

E.9

ODSD

8"8"

4"SD

G

G

1 1/4"

1"1"

3/4"3/4"

3/4"

3/4"3/4" 1/2"

2"

1 1/2"

3/4"3/4"

1 1/4"

3/4"3/4"

1 1/2"

2"

1/2" 3/4"3/4"S-3

S-4

S-3

8

WH-1

3/4"

3/4"

3/4"

3/4"

9 9

9

1"1"

3/4"

3/4"

2"

2 1/2"

10

2"

2"2"

10

11

S-1

9

3/4"3/4"

1 1/4"

8

WH-1

WH-1

3/4"

3/4"3/4"

13

2"

2 1/2"

4" FCO-1

1/2"3/4"

2"1 1/4"

3/4"

9

9

9

9

9

9

99

141110

15

19

CN-1

2

15

1

16

15

6

9

123/4"

3/4"

3/4"

1 1/4"

3/4"

1 1/2"

3/4" 3/4"

1 1/2"

1"

4"4"

ODSD

8"8"

8"8"

18

CN-1

3" RD-2

106 S.F.

3" RD-2

52 S.F.

6" CN-1

20

17

OD

6"6"

SD

OD

OD

6"

6"

SD

8

8

8

2"

2"

2"

2"

2"

3"

6

21

21

22

2"

22

3" FD-2W/ TG-1

2"FD-1W/ TG-1 2"FD-1

W/ TG-1

22

1"1" 1 1/4"

2"

22

20

2"

2"

3/4"

2"

2 1/2"

2 1/2"

1 1/2"

3/4"

22

1 1/4"3/4"

3/4"

1"

9

FLEXCLASSROOM

113

CLASSROOM

126

BOYS

112

CLASSROOM

127

CLASSROOM

128

CLASSROOM

129

KINDERGARTEN

130

KINDERGARTEN

131 KINDERGARTEN

132

KINDERGARTEN

133

COMMONS

134

ART

108

STORAGE

130B

RR

130A

STORAGE

131B

RR

131A

STORAGE

132B

RR

132A

RR

133B

STORAGE

133A

LIBRARY MEDIACENTER

109

GIRLS

110

CUST.

111

CORRIDOR

103

OFFICE

109B

VESTIBULE

109A

STAIR 1

S1.1

STORAGE

108B

VESTIBULE

106D

KILN

108A

3

4

P-142

DRAWING NOTES #

1. 5" SD DOWN THRU FLOOR. RE: P-100B FOR CONTINUATION.

2. 5" OD DOWN TO CONDUCTOR NOZZLE.

3. 6" OD DOWN FROM ABOVE CEILING, FIELD VERIFY EXACT LOCATION. PIPE TO LOCATIONINDICATED, DROP IN CHASE AND CONNECT TO 6" CN-1.

4. (E) 6" SD DOWN FROM ROOF. CONNECT TO NEW 6" SD AND ROUTE AS SHOWN.

5. 6" SD DOWN TO UNDERGROUND.

6. 1/2" CW AND 1/2" HW UP TO SINK ON FLOOR ABOVE AND 1/2" CW AND 1/2" HW DROP TO SINK.

7. REMOVE CAP AND CONNECT 2-1/2" CW, 2" HW, & 1" HWC TO EXISTING DOMESTIC WATER.

8. BALANCE CIRCUIT SETTER TO 0.5 GPM.

9. 2" VENT, 1/2" CW AND 1/2" HW DROP TO SINK.

10. 2" VENT RISE TO 3" VTR.

11. 4" SD AND 4" OD DOWN FROM ROOF DRAIN.

12. 2" SANITARY, 1/2" CW AND 1/2" HW UP TO SINK ABOVE.

13. 1-1/4" GAS RISE UP TO MAU-3 ON ROOF.

14. 5" SD AND 5" OD FROM DRAINS ABOVE, INCREASE TO 8" SD AND 8" OD AND OFFSET ABOVECEILING AS INDICATED.

15. 3/4" CW DOWN IN WALL TO WALL HYDRANT.

16. 6" SD DOWN THRU FLOOR. RE: P-100B FOR CONTINUATION.

17. 6" OD DOWN TO CONDUCTOR NOZZLE.

18. 8" SD DOWN THRU FLOOR. RE: P-100B FOR CONTINUATION.

19. 8" OD DOWN TO CONDUCTOR NOZZLE.

20. 3" SD DOWN THRU FLOOR. RE: P-100B FOR CONTINUATION.

21. 2" SANITARY DOWN FROM ABOVE.

22. 2" VENT RISE.

ENVIS

ION

MEC

HA

NIC

AL

EN

GIN

EER

S I

NC

.

9777 P

yramid

Court, S

uit

e 1

20

Engle

wood, C

O 8

0112

Tel-

303-6

88-0

223

Fax- 303-6

88-3

584

envis

ionengrs.c

om

Proje

ct #

Date

Drawn By

Checked By:

Project Number

Sheet Name

Copyright:

ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE

DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF

MOA ARCHITECTURE

NOT FOR

CONSTRUCTION

AD

DIT

ION

S A

ND

RE

NO

VA

TIO

NS

016-0

09

7/29

/201

6 10

:38:

25 A

M

P-101B

FIRST FLOORPLUMBING PLAN -AREA B - PHASE

1A

SIE

RR

A E

LE

ME

NT

AR

Y S

CH

OO

L

JJR

08.04.16

16100.00

7771

Oak

St.

Arv

ada,

CO

800

05

BID SET

JCF

PLAN NORTH

AREA 'A'EXISTINGBUILDING

AREA 'B'

AREA 'C'

KEYPLANPLAN NORTH

1/8" = 1'-0"

FIRST FLOOR PLUMBING PLAN - AREA B1

REVISION DATE

lmedina
Ellipse

F.E

.C.

F.E.C.

S-1

P-140

4

S-1

S-1

S-1

S-1

1 2 3 4

8

910

12

A

B

C

E

G

D

RE

:

MA

TC

HLIN

E

MA

TC

HLIN

E

P-1

01B

RE:

MATCHLINE

MATCHLINE

P-101B

6

P-142

7

9

3/4"3/4"

9

S-1

S-1

10

10

7

8

8

10

7

8

4" FCO-1

3/4"3/4"3/4"

3/4"3/4"

WH-1 3/4"

1 1/4"

3/4"

1 1/4"

3/4"3/4"3/4"

8

8910

1 1/4"

3/4"

1 1/4"

3/4"3/4"

3/4"3/4"

1"

3/4"

2"

3/4"

1 1/2"1 1/2"

1 1/2"1 1/2"

8

3/4"

1"

8

3/4"

1 1/2"

2"

3/4"

3/4"

2"

3/4"3/4"3/4"

EWC-1

14

4" CN-112

11

5" CN-1

2

1

2

1

5" CN-1

6" CN-1

6

5

3" CN-1

3

4

4" CN-1

11

12

15

WH-1

153/4"

7

9

9

10

7

7

9

13

16

18

17

10

3" RD-2

121 S.F.

3" RD-2

109 S.F.

S-1

9

107

3/4"3/4"3/4"

3/4"3/4"3/4"

S-1

9

10

7

1"

9

10

7

S-1

1"

1"

3/4"

1"

1"

3/4"

3

7

9

1"

CLASSROOM

119

CLASSROOM

118

CLASSROOM

117

CLASSROOM

116

CLASSROOM

122

CLASSROOM

120

CLASSROOM

123

CLASSROOM

115

RESOURCE

ROOM

125

TEACHER

WORK ROOM

121

STAFF RR

124

ELEC.

125A

STAIR 2

S2.1

VESTIBULE

114

FLEX

CLASSROOM

113

CLASSROOM

126

DRAWING NOTES #

1. 5" SD DOWN THRU FLOOR. RE: P-100C FOR CONTINUATION.

2. 5" OD DOWN TO CONDUCTOR NOZZLE.

3. 3" SD DOWN THRU FLOOR. RE: P-100C FOR CONTINUATION.

4. 3" OD DOWN TO CONDUCTOR NOZZLE.

5. 6" SD DOWN THRU FLOOR. RE: P-100C FOR CONTINUATION.

6. 6" OD DOWN TO CONDUCTOR NOZZLE.

7. 1/2" CW AND 1/2" HW UP TO SINK ON FLOOR ABOVE AND 1/2" CW AND 1/2" HW DROP TO

SINK.

8. BALANCE CIRCUIT SETTER TO 0.5 GPM.

9. 2" SANITARY DOWN FROM SINK ABOVE.

10. 2" VENT RISE.

11. 4" SD DOWN THRU FLOOR. RE: P-100C FOR CONTINUATION.

12. 4" OD DOWN TO CONDUCTOR NOZZLE.

13. 2" VENT DROP TO ELECTRIC WATER COOLER.

14. 2" PUMPED DISCHARGE FROM SUMP PUMP.

15. 3/4" CW DOWN IN WALL TO WALL HYDRANT.

16. 2" SANITARY UP TO ELECTRIC WATER COOLER ABOVE.

17. 1/2" CW UP TO ELECTRIC WATER COOLER ON FLOOR ABOVE

18. 1/2" CW DROP TO ELECTRIC WATER COOLER.

ENVIS

ION

MEC

HA

NIC

AL

EN

GIN

EER

S I

NC

.

9777 P

yramid

Court, S

uit

e 1

20

Engle

wood, C

O 8

0112

Tel-

303-6

88-0

223

Fax- 303-6

88-3

584

envis

ionengrs.c

om

Proje

ct #

Date

Drawn By

Checked By:

Project Number

Sheet Name

Copyright:

ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE

DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF

MOA ARCHITECTURE

NOT FOR

CONSTRUCTION

AD

DIT

ION

S A

ND

RE

NO

VA

TIO

NS

016-0

09

8/3/

2016

2:4

7:51

PM

P-101C

FIRST FLOORPLUMBING PLAN -AREA C - PHASE

1A

SIE

RR

A E

LE

ME

NT

AR

Y S

CH

OO

L

JJR

08.04.16

16100.00

7771

Oak

St.

Arv

ada,

CO

800

05

BID SET

JCF

PLAN NORTH

AREA 'A'EXISTINGBUILDING

AREA 'B'

AREA 'C'

KEYPLANPLAN NORTH

1/8" = 1'-0"

Overall First Floor Plumbing Plan1

REVISION DATE

lmedina
Ellipse

F.E.C.

F.E

.C.

LIBRARY MEDIACENTER

109

BOY'S

203

CLASSROOM

216

CLASSROOM

217

CLASSROOM

218

4TH GRADE

219

GIRLS

201

CUSTODIAL

202

CORRIDOR

200

STAIR 1

S1.2

P-140

6

S-1

S-1

S-1

1 2 3 4

6

5

8 9 10 1213

E

G

K

L

J

M

D

F

H

6.5

RE

:

MA

TC

HLIN

E

MA

TC

HLIN

E

P-1

02C

RE:

MATCHLINE

MATCHLINE

P-102C

2

P-142

E.A E.B

E.1

E.2

E.3

E.4

E.5

E.6

E.7

E.8

E.9

4"4"

SD

OD

SD

OD

2

7

85

6

3

4

1

7

2" 2"

2"

2"

2"

2"

67

3" VTR

5

5

DRAWING NOTES #

1. 5" SD DOWN THRU FLOOR. RE: P-101B FOR CONTINUATION.

2. 5" OD DOWN THRU FLOOR. RE: P-101B FOR CONTINUATION.

3. 5" SD UP TO ROOF DRAIN.

4. 5" OD UP TO ROOF DRAIN.

5. 1/2" CW AND 1/2" HW UP TO SINK FROM BELOW.

6. 2" VENT RISE.

7. 2" SANITARY DOWN THRU FLOOR.

8. 2" VENT RISE TO 3" VTR.

ENVIS

ION

MEC

HA

NIC

AL

EN

GIN

EER

S I

NC

.

9777 P

yramid

Court, S

uit

e 1

20

Engle

wood, C

O 8

0112

Tel-

303-6

88-0

223

Fax- 303-6

88-3

584

envis

ionengrs.c

om

Proje

ct #

Date

Drawn By

Checked By:

Project Number

Sheet Name

Copyright:

ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE

DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF

MOA ARCHITECTURE

NOT FOR

CONSTRUCTION

AD

DIT

ION

S A

ND

RE

NO

VA

TIO

NS

016-0

09

7/29

/201

6 10

:38:

29 A

M

P-102B

SECOND FLOORPLUMBING PLAN -AREA B - PHASE

1A

SIE

RR

A E

LE

ME

NT

AR

Y S

CH

OO

L

JJR

08.04.16

16100.00

7771

Oak

St.

Arv

ada,

CO

800

05

BID SET

JCF

PLAN NORTH

AREA 'A'EXISTINGBUILDING

AREA 'B'

AREA 'C'

KEYPLANPLAN NORTH

1/8" = 1'-0"

SECOND FLOOR PLUMBING PLAN - AREA B1

REVISION DATE

lmedina
Ellipse

F.E

.C.

F.E.C.

CLASSROOM

209

CLASSROOM

208

CLASSROOM

207

CLASSROOM

206

FLEXCLASSROOM

204

RESOURCEROOM

215

ELEC.

215A

CLASSROOM

213

CLASSROOM

212

CLASSROOM

210

TEACHERWORK ROOM

211

STAFF RR

214

STAIR 2

S2.2

P-140

5

S-1

S-1

S-1

CLASSROOM

205

S-1

S-1

S-1

S-1

S-1

S-1

1 2 3 4

8

910

12

A

B

C

E

G

D

RE

:

MA

TC

HLIN

E

MA

TC

HLIN

E

P-1

02B

RE:

MATCHLINE

MATCHLINE

P-102B

6

P-142

EWC-1

OD

SD

OD

SD

5"5"

4"4"

5"5"

OD

SD

3"3"

OD

SD

4"4"

OD

SD

6"6"

4"4"

S-1

14

13

15

16

11

12

10

9

14

13

15

16

17

18

16

15

2

1

4

3

2

1

3

4

6

5

68

5

67

6 7

5

6

567

68

6 768

5

6 8

7

6 7

5

6

2"

2"

2"

6

5

6 7

2"

6

19

7

6 867

5

6 7

5

6

2"

6 8

567

5

DRAWING NOTES #

1. 5" SD DOWN THRU FLOOR. RE: P-101B FOR CONTINUATION.

2. 5" OD DOWN THRU FLOOR. RE: P-101B FOR CONTINUATION.

3. 5" SD UP TO ROOF DRAIN.

4. 5" OD UP TO ROOF DRAIN.

5. 1/2" CW AND 1/2" HW UP TO SINK FROM BELOW.

6. 2" VENT RISE.

7. 2" SANITARY DOWN THRU FLOOR.

8. 2" VENT RISE TO 3" VTR.

9. 3" SD DOWN THRU FLOOR. RE: P-101C FOR CONTINUATION.

10. 3" OD DOWN THRU FLOOR. RE: P-101C FOR CONTINUATION.

11. 3" SD UP TO ROOF DRAIN.

12. 3" OD UP TO ROOF DRAIN.

13. 4" SD DOWN THRU FLOOR. RE: P-101C FOR CONTINUATION.

14. 4" OD DOWN THRU FLOOR. RE: P-101C FOR CONTINUATION.

15. 4" SD UP TO ROOF DRAIN.

16. 4" OD UP TO ROOF DRAIN.

17. 6" SD DOWN THRU FLOOR. RE: P-101C FOR CONTINUATION.

18. 6" OD DOWN THRU FLOOR. RE: P-101C FOR CONTINUATION.

19. 1/2" CW UP TO WATER COOLER FROM BELOW.

ENVIS

ION

MEC

HA

NIC

AL

EN

GIN

EER

S I

NC

.

9777 P

yramid

Court, S

uit

e 1

20

Engle

wood, C

O 8

0112

Tel-

303-6

88-0

223

Fax- 303-6

88-3

584

envis

ionengrs.c

om

Proje

ct #

Date

Drawn By

Checked By:

Project Number

Sheet Name

Copyright:

ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE

DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF

MOA ARCHITECTURE

NOT FOR

CONSTRUCTION

AD

DIT

ION

S A

ND

RE

NO

VA

TIO

NS

016-0

09

8/3/

2016

2:4

1:38

PM

P-102C

SECOND FLOORPLUMBING PLAN -AREA C - PHASE

1A

SIE

RR

A E

LE

ME

NT

AR

Y S

CH

OO

L

JJR

08.04.16

16100.00

7771

Oak

St.

Arv

ada,

CO

800

05

BID SET

JCF

PLAN NORTH

AREA 'A'EXISTINGBUILDING

AREA 'B'

AREA 'C'

KEYPLANPLAN NORTH

1/8" = 1'-0"

SECOND FLOOR PLUMBING PLAN - AREA C1

REVISION DATE

lmedina
Ellipse

6

5

13

E

K

L

J

M

F

H

6.5

(E)6"RD (E)4"RD

(E)4"OD(E)6"OD

(E)4"RD (E)4"RD

(E)6"RD

(E)GAS VENT (E)3"VTR (E)3"VTR

(E)3"VTR

(E)3"VTR

(E)3"VTR

(E)6"RD

(E)3"VTR

(E)4"RD

(E)3"RD

RE

:

MA

TC

HLIN

E

MA

TC

HLIN

E

P-1

21

B

RE

:

MA

TC

HLIN

E

MA

TC

HLIN

E

P-1

21

B

(E)3"VTR

(E)4"RD

(E)GPR

(E)3/4"

(E)1"

RE: MECH

(E)G

(E)GPR

RE: MECH

(E)1"

(E)1 1/2"

(E)3"VTR

E.A E.B E.C E.D E.E E.F E.G E.H E.J

E.1

E.2

E.3

E.4

E.5

E.6

E.7

E.8

E.9

E.10

1

PHASE 1B

6

5

13

E

K

L

J

M

F

H

6.5

E.A E.B E.C E.D E.E E.F E.G

E.H

E.J

E.1

E.2

E.3

E.4

E.5

E.6

E.7

E.8

E.9

E.10

RTU-7RE: MECH

EF-10RE: MECH

EF-9RE: MECH

1

3"RD-2

99 S.F.

1

DRAWING NOTES #

1. 3" ROOF DRAIN PIPING TO OFFSET TO EXTERNAL DOWNSPOUT.

ENVIS

ION

MEC

HA

NIC

AL

EN

GIN

EER

S I

NC

.

9777 P

yramid

Court, S

uit

e 1

20

Engle

wood, C

O 8

0112

Tel-

303-6

88-0

223

Fax- 303-6

88-3

584

envis

ionengrs.c

om

Proje

ct #

Date

Drawn By

Checked By:

Project Number

Sheet Name

Copyright:

ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE

DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF

MOA ARCHITECTURE

NOT FOR

CONSTRUCTION

AD

DIT

ION

S A

ND

RE

NO

VA

TIO

NS

016-0

09

8/3/

2016

2:4

1:41

PM

P-121A

ROOF PLUMBINGPLAN - AREA A -PHASES 1A & 1B

SIE

RR

A E

LE

ME

NT

AR

Y S

CH

OO

L

JJR

08.04.16

16100.00

7771

Oak

St.

Arv

ada,

CO

800

05

BID SET

JCF

PLAN NORTH

AREA 'A'EXISTINGBUILDING

AREA 'B'

AREA 'C'

KEYPLAN 1/8" = 1'-0"

ROOF PLUMBING PLAN - AREA A1

PLAN NORTH

REVISION DATE

lmedina
Ellipse

1 2 3 4

6

5

8 9 10 1213

E

G

K

L

J

M

D

F

H

6.5

RE

:

MA

TC

HLIN

E

MA

TC

HLIN

E

P-1

21

A

RE

:

MA

TC

HLIN

E

MA

TC

HLIN

E

P-1

21

A

RE

:

MA

TC

HLIN

E

MA

TC

HLIN

E

P-1

21C

RE:

MATCHLINE

MATCHLINE

P-121C

5"OD-1

5"RD-1

4"RD-1

4"OD-11,450 S.F.

4,012 S.F.

4"OD-1

4"RD-12,468 S.F.

8"RD-1

8"OD-17,787 S.F.

E.A E.B

E.1

E.2

E.3

E.4

E.5

E.6

E.7

E.8

E.9

4"RD-1

4"OD-12,427 S.F.

G

1 1/4"

3" VTR

3" VTR

3" VTR

3" VTR

3" VTR

3" VTR

3" VTR

1

1

1

1

1

1

22

P-500

1 2 3 4

6

5

7 8 9 10 11 1213

E

G

K

L

J

M

D

F

H

6.5

E.A E.B

E.2

E.3

E.4

E.5

E.6

E.7

E.8

E.9

RTU-6RE: MECH

RTU-7RE: MECH

EF-10RE: MECH

EF-9RE: MECH

EF-12RE: MECH

RTU-8RE: MECH

MAU-3RE: MECH

EF-11RE: MECH

1

DRAWING NOTES #

1. PROVIDE VENT CAP AT THE TERMINATION OF THE VTR.

2. 1-1/4" GAS PIPING FROM BELOW. ROUTE TO MAU-3.

ENVIS

ION

MEC

HA

NIC

AL

EN

GIN

EER

S I

NC

.

9777 P

yramid

Court, S

uit

e 1

20

Engle

wood, C

O 8

0112

Tel-

303-6

88-0

223

Fax- 303-6

88-3

584

envis

ionengrs.c

om

Proje

ct #

Date

Drawn By

Checked By:

Project Number

Sheet Name

Copyright:

ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE

DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF

MOA ARCHITECTURE

NOT FOR

CONSTRUCTION

AD

DIT

ION

S A

ND

RE

NO

VA

TIO

NS

016-0

09

7/29

/201

6 10

:38:

33 A

M

P-121B

ROOF PLUMBINGPLAN - AREA B -

PHASE 1A

SIE

RR

A E

LE

ME

NT

AR

Y S

CH

OO

L

JJR

08.04.16

16100.00

7771

Oak

St.

Arv

ada,

CO

800

05

BID SET

JCF

PLAN NORTH

AREA 'A'EXISTINGBUILDING

AREA 'B'

AREA 'C'

KEYPLANPLAN NORTH

1/8" = 1'-0"

ROOF PLUMBING PLAN - AREA B1

REVISION DATE

lmedina
Ellipse

1 2 3 4

8

910

12

A

B

C

E

G

D

RE

:

MA

TC

HLIN

E

MA

TC

HLIN

E

P-1

21B

RE:

MATCHLINE

MATCHLINE

P-121B

4"RD-1

4"OD-1

5"OD-1

5"RD-1

5"OD-1

5"RD-1

4"OD-1

4"RD-1

4"OD-1

4"RD-1

3"OD-1

3"RD-1

2,134 S.F.

1,900 S.F.

893 S.F.

1,284 S.F.

2,942 S.F.

2,931 S.F.

3" VTR

3" VTR

3" VTR

3" VTR

3" VTR

3" VTR

3" VTR

1 2 3 4

78

910

11 12

A

B

C

E

G

D

RTU-9RE: MECH

RTU-10RE: MECH

EF-13RE: MECH

EF-14RE: MECH

1

1

1

1

1

1

1

DRAWING NOTES #

1. PROVIDE VENT CAP AT THE TERMINATION OF THE VTR.

ENVIS

ION

MEC

HA

NIC

AL

EN

GIN

EER

S I

NC

.

9777 P

yramid

Court, S

uit

e 1

20

Engle

wood, C

O 8

0112

Tel-

303-6

88-0

223

Fax- 303-6

88-3

584

envis

ionengrs.c

om

Proje

ct #

Date

Drawn By

Checked By:

Project Number

Sheet Name

Copyright:

ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE

DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF

MOA ARCHITECTURE

NOT FOR

CONSTRUCTION

AD

DIT

ION

S A

ND

RE

NO

VA

TIO

NS

016-0

09

7/29

/201

6 10

:38:

35 A

M

P-121C

ROOF PLUMBINGPLAN - AREA C -

PHASE 1A

SIE

RR

A E

LE

ME

NT

AR

Y S

CH

OO

L

JJR

08.04.16

16100.00

7771

Oak

St.

Arv

ada,

CO

800

05

BID SET

JCF

PLAN NORTH

AREA 'A'EXISTINGBUILDING

AREA 'B'

AREA 'C'

KEYPLANPLAN NORTH

1/8" = 1'-0"

ROOF PLUMBING PLAN - AREA C1

REVISION DATE

lmedina
Ellipse

(E)4"FS

(E)SINK

(E)SINK

(E)4"FS(E)SINK

(E)4"FS

(E)3"FS

(E)3"FS

(E)SINK(E)2"FD

(E)2"FD

(E)2"FD

(E)6"FS (E)4"FS(E)WC(E)2"FD

(E)LAV

(E)WB

(E)MSB

(E)4"FCO

(E)4"FCO

REFER TO FIREPROTECTIONPLANS

(E)PRV-1(E)PRV-2(E)PRV-3

(E)BFP-1(E)BFP-2

(E)D

(E)SD(E)SD(E)SD

(E)P

D(E)3"

(E)6"(E)6"

TO (E)6"RD(E)3"

(E)1 1/2"(E)3"(E)3/4"

TO (E)4"RD

(E)S

D

(E)HB

(E)G

(E)G

(E)G

(E)G

(E)GAS METER BY XCEL

(E)6"

(E)6"

(E)1 1/4"

(E)2"

(E)GWH-2

(E)GWH-1

(E)C

W

(E)6"

(E)B-1B-2

1

RE: MECH RE: MECH

G

(E)G

(E)G

(E)G

(E)C

W

(E)H

W

(E)H

WC

(E)3"V UPTO (E)3"VTR

(E)4" GASVTR

(E)3"V UPTO (E)3"VTR

(E)GPR

(E)G

(E)G

(E)G

(E)1 1/2"

(E)G

(E)G

(E)GPR

(E)HW

(E)HWC

(E)1 1/2"

E.C E.D E.E E.F

E.1

E.2

E.3

E.4

1 1/4"

1 1/4"

G

3"FS-1

G

2

42 40

2"

3"FS-1 3"FS-1

3

3

3939

3

1/2"

1/2"1/2"

1/2" 2"

41

4

4

41

4

CP-1 24

25

38

L-1L-1 L-1

L-1L-2

L-1L-1

L-1 L-1L-2

UR-1

UR-2

WC-1WC-1

WC-2

WC-1WC-1

WC-1WC-2

GIRL'S

110

BOY'S

112

CUSTODIAL

111

CORRIDOR

103

3

10

F

H

MSB-1

23

2"

1 1/2"

3/4"

26

26

26

2626

26

2" FD-1W/ TG-1

2" FD-1W/ TG-1

2" FD-1W/ TG-1

2" FD-1W/ TG-1

1"1"

1"1"

1"1"

2"

3/4"1 1/2"2 1/2"

12

6 30

36

12

37

12

33

3/4"3/4"3/4"

2"

HB-1

HB-1

31

31

21

21

35

29

21

21

376

29

29

29

2 1/2"

WC-2

L-2

S-2 W/GDU-1

STAFF RR

124

2ND GRADE

123

RESOURCEROOM

125

9

D

WCO-1

1 1/2"

2"

1" 3/4"

3/4"

4"

2"

12

1314

1615

6

6

17

18

2"

2" FD-1W/ TG-1

21

RR

132A

RR

131A

WC-3WC-3

2" FD-1W/ TG-1

2" FD-1W/ TG-1

WCO-1

L-1L-1

3/4"3/4"3/4"

6

18

19

20

1 1/2"

2"3/4"

WC-2

L-2

S-2 W/GDU-1

RESOURCEROOM

215

STAFF RR

214

CLASSROOM

213

9

D

WCO-1

2"

2"

2"

6

5

76

9

10

11

2" FD-1W/ TG-1

8

L-1L-1

L-1L-1

L-2

L-1L-1

L-1L-1

L-2

UR-1UR-2

WC-1

WC-1

WC-2

WC-1WC-1

WC-1WC-1

WC-2

GIRLS

201

BOY'S

203

CUSTODIAL

202

CORRIDOR

200

3

10

F

H

MSB-1

2"

2" 2926 26

26 26

22

28

27

SD

OD 4"

4"

4"4"

2"

SD

OD

2" FD-1W/ TG-1

2" FD-1W/ TG-1

2" FD-1W/ TG-1

2" FD-1W/ TG-1

8

33

HB-1

HB-11"

3/4"30

29

294" WCO-1

31

31

2"34

66

6

DRAWING NOTES #

1. CONNECT 4" GAS TO EXISTING 6" GAS FOR BOILER.

2. CONNECT 1-1/4" GAS TO EXISTING 6" GAS.

3. CONNECT 2" VENT TO EXSITING 3" VENT.

4. 2" VENT DROP IN WALL TO FLOOR SINK.

5. 1/2" CW AND 1/2" HW UP TO SINK FROM BELOW.

6. 2" VENT RISE.

7. 2" SANITARY DOWN THRU FLOOR.

8. 2" VENT RISE TO 3" VTR.

9. 1/2" CW AND 1/2" HW UP TO LAVATORY FROM BELOW. 2" SANITARY DOWN AND 2" VENT RISE FROM LAVATORY.

10. 4" SANITARY DOWN THRU FLOOR.

11. 4" SANITARY DOWN, 2" VENT RISE FROM WATER CLOSET. 1" CW RISE UP TO WATER CLOSET FROM BELOW.

12. BALANCE CIRCUIT SETTER TO 0.5 GPM.

13. 1/2" CW AND 1/2" HW DOWN TO LAVATORY. 2" SANITARY DOWN AND 2" VENT RISE FROM LAVATORY.

14. 1/2" CW AND 1/2" HW UP TO LAVATORY ABOVE. 2" SANITARY DOWN FROM LAVATORY ABOVE.

15. 1/2" CW AND 1/2" HW UP TO SINK ON FLOOR ABOVE AND 1/2" CW AND 1/2" HW DROP TO SINK.

16. 2" SANITARY DOWN FROM SINK ABOVE.

17. 1" CW UP TO WATER CLOSET ABOVE AND 1" CW DOWN TO WATER CLOSET.

18. 2" VENT RISE FROM WATER CLOSET.

19. 1" CW DOWN TO WATER CLOSET.

20. 2" VENT, 1/2" CW AND 1/2" HW DOWN TO LAVATORY.

21. 2" SANITARY WITH P-TRAP UP TO FLOOR DRAIN.

22. 2" VENT RISE FROM MOP BASIN. 1/2" CW AND 1/2" HW TO MOP BASIN FROM BELOW.

23. 2" VENT RISE FROM MOP BASIN. 1/2" CW AND 1/2" HW DOWN TO MOP BASIN.

24. REPLACE EXISTING CIRCULATION PUMP WITH NEW CP-1 FOR ADDED LOAD.

25. NEW 4" GAS LINE DROP TO SERVICE B-2.

26. 1/2" CW AND 1/2" HW TO LAVATORY. 2" SANITARY DOWN AND 2" VENT RISE FROM LAVATORY.

27. 4" SD UP TO ROOF DRAIN.

28. 4" OD UP TO ROOF DRAIN.

29. 4" SANITARY, 2" VENT AND 1" CW TO WATER CLOSET.

30. 2" SANITARY, 2" VENT AND 3/4" CW TO URINAL.

31. 1/2" CW TO HOSE BIBB.

32. WHA-2, PROVIDE ACCESS TO WATER HAMMER ARRESTOR.

33. WHA-4, PROVIDE ACCESS TO WATER HAMMER ARRESTOR.

34. 2-1/2" CW UP FROM FLOOR BELOW.

35. 2-1/2" CW UP TO FLOOR ABOVE.

36. 2" DRAIN FROM ELEVATOR SUMP PUMP TO DISCHAGE IN TO MOP BASIN WITH AIRGAP.

37. 3/4" HWC DOWN FROM LAVS ABOVE.

38. REFER TO DETAIL 15/P-500 FOR BYPASS OF PRV STATION FOR IRRIGATION SYSTEM.

39. 1/2" HW CONNECT TO EXISTING HW AS SHOWN.

40. 1/2" CW CONNECT TO EXISTING CW AS SHOWN.

41. 1/2" HW DOWN TO HOT FOOD WELL.

42. 1/2" CW AND 1/2" HW DOWN TO TILTING KETTLE.

ENVIS

ION

MEC

HA

NIC

AL

EN

GIN

EER

S I

NC

.

9777 P

yramid

Court, S

uit

e 1

20

Engle

wood, C

O 8

0112

Tel-

303-6

88-0

223

Fax- 303-6

88-3

584

envis

ionengrs.c

om

Proje

ct #

Date

Drawn By

Checked By:

Project Number

Sheet Name

Copyright:

ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE

DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF

MOA ARCHITECTURE

NOT FOR

CONSTRUCTION

AD

DIT

ION

S A

ND

RE

NO

VA

TIO

NS

016-0

09

7/29

/201

6 10

:38:

47 A

M

P-140

ENLARGED PLANS

SIE

RR

A E

LE

ME

NT

AR

Y S

CH

OO

L

JJR

08.04.16

16100.00

7771

Oak

St.

Arv

ada,

CO

800

05

BID SET

JCF

1/4" = 1'-0"

ENLARGED PLUMBING PLAN - BOILER ROOM & KITCHEN1

PLAN NORTH

1/4" = 1'-0"

ENLARGED PLUMBING PLAN - FIRST FLOOR RESTROOM GROUP2

PLAN NORTH

1/4" = 1'-0"

ENLARGED PLUMBING PLAN - FIRST FLOOR STAFF RESTROOM4 1/4" = 1'-0"

ENLARGED PLUMBING PLAN - KINDERGARTEN RESTROOMS3 1/4" = 1'-0"

ENLARGED PLUMBING PLAN - SECOND FLOOR STAFF RESTROOM5

PLAN NORTHPLAN NORTH PLAN NORTH

1/4" = 1'-0"

ENLARGED PLUMBING PLAN - SECOND FLOOR RESTROOM GROUP6

PLAN NORTH

REVISION DATE

lmedina
Ellipse

WC-3

WC-3

L-1

L-1

1"

1"

1/2"

1/2"

3/4"

3/4"

1-1/2"

WCO-1

2"FD-1

W/ TG-1

2"FD-1

W/ TG-1

L-1

L-1

WC-3

WC-3

2"

2"

2"

2"

2"

2"2"

4"4"

4"

WC-2

L-2

L-2

S-2

W/ GDU-1

S-2

W/ GDU-1

WC-2

2"

1-1/2"

3/4"

3/4"

3/4"

3/4"

1"1/2"

1/2"1/2"

1/2"

1"

1"

WCO-1

WCO-1

WC-2

WC-2

2"FD-1

W/ TG-1

2"FD-1

W/ TG-1

L-2

L-2

S-2

W/ GDU-1

S-2

W/ GDU-1

4"

2"

2"

2"

2"2"

2"

2"2"

2"

4"

4" 4"

4"

2"

2"2"

2"

4"

4"

3"

S-1

HB-1

HB-1

3/4"3/4"

UR-1

UR-1

WC-1

WC-2

WC-2

WC-1

WC-1

1"

3/4"

3/4"

1"

1"1"

WC-1

WC-1

WC-1

3/4"3/4"

2 1/2"

2 1/2" 2"

1 1/2"

3/4"3/4"

3/4"3/4"3/4"

HB-1

HB-1

WC-2

WC-2

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

L-1

L-2

L-1

L-1

L-1

1"

1/2"

3/4"

1"1/2"

1/2"

L-1

L-1

L-1

L-1

L-2

L-1

L-1

L-1

L-1

L-2

1/2"

3/4"

1"

1/2"

1/2" 1/2"

1/2"

1"1/2"

L-1

L-1

L-1

L-1

L-2

3/4"

L-1

L-1

L-1

L-1L-2

2"

2"

2"

2"2"

4"

2"

2"

S-1

FD-1

FD-1

FD-1

FD-1

FD-1

L-2

L-1

L-1

L-1L-1

3"

4"

4"

4"

2" 2"

2"4"

2"

4"

3"

2"

3"

2"

2"

2"

2"

2"

2"

2"

2"

2" 2"

2"

2"

2"2"2"

2"

2"

4"

4"

2"

2"

L-2

L-1

L-1

L-1

L-1

L-2

L-1

L-1

L-1

L-1

WC-1

WC-1

WC-2

WC-2

WC-1

WC-1

WC-2

WC-2

2"WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

3"

2"

2"

2"

2"

2"2"

2"

2"

2"

2"

ENVIS

ION

MEC

HA

NIC

AL

EN

GIN

EER

S I

NC

.

9777 P

yramid

Court, S

uit

e 1

20

Engle

wood, C

O 8

0112

Tel-

303-6

88-0

223

Fax- 303-6

88-3

584

envis

ionengrs.c

om

Proje

ct #

Date

Drawn By

Checked By:

Project Number

Sheet Name

Copyright:

ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE

DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF

MOA ARCHITECTURE

NOT FOR

CONSTRUCTION

AD

DIT

ION

S A

ND

RE

NO

VA

TIO

NS

016-0

09

7/29

/201

6 10

:38:

49 A

M

P-142

PLUMBINGISOMETRICS

SIE

RR

A E

LE

ME

NT

AR

Y S

CH

OO

L

JJR

08.04.16

16100.00

7771

Oak

St.

Arv

ada,

CO

800

05

BID SET

JCF

1RESTROOM GROUP ISOMETRIC - DOMESTIC WATER

2RESTROOM GROUP ISOMETRIC - SANITARY & VENT

REVISION DATE

3RESTROOM GROUP ISOMETRIC - DOMESTIC WATER 131A & 132A

4RESTROOM GROUP ISOMETRIC - SANITARY & VENT 131A & 132A

5RESTROOM GROUP ISOMETRIC - DOMESTIC WATER 214 & 124

6RESTROOM GROUP ISOMETRIC - SANITARY & VENT 214 & 124

lmedina
Ellipse

LOCKING NUT

SUPPORT NUT

NUT AND BOLT

180° GALVANIZED SHEET STEELSADDLE MIN. 9" LONG, RE: SPEC.

HANGER ROD

HEAVY DUTY CLEVIS HANGER

VAPOR BARRIER INSULATION, RE:SPEC

180° INSERT CALCIUM SILICATE INSULATION OFSAME THICKNESS AS PIPE INSULATION

METAL BOX FASTEN TO STUDS OR WALL

INTEGRAL WATER HAMMER ARRESTOR

1/4 TURN STOP VALVE

3/8" OUTLET CONNECTION

1/2" INLET CONNECTION

1/2"HW, SEE PLAN

1/2"TW TO LAVATORY/ SINK

1/2"CW TO LAVATORY/SINK

SERVICE UNION (TYP.)

TMV-1

1/2"CW, SEE PLAN

WALL CABINET AS SPECIFIED

ROUND SECURED CHROME COVERWITH VANDAL RESISTANT CENTERSCREW

WALL

WASTE

CLEANOUT PLUG

4"

SINK, SEEPLANS FORDESIGNATION

2" WCO-1

2"W & V WITHINWALL

1-1/2" WASTE TO WALLW/ ESCUTCHEON

INLET

OUTLETHO-HUBCOUPLING

1-1/2" THREADEDADAPTER

FINISHED FLOOR

BASE CABINETFLOOR

2" CHROMEPLATED WASTE

14" SPACE FORBASKET REMOVAL

SPACING DISTANCE TO EXISTINGROOF DRAIN. RE: ARCH CLAMPING RING RE: SPECS.

BALLAST

DRAIN RECEIVER CLIP

DRAIN RECEIVER

ROOF SYSTEM RE: ARCH.

UNDERDECK CLAMPROOF DRAIN CONDUCTOR

PIPING. RE: SPECS. RE: SPECS FOR INSTALLATIONCOORDINATE OPENING IN

EXISTING ROOF W/ ARCHITECTAND GENERAL CONTRACTOR

SLEEVE

GAS VENT

PATE PIPE SEAL

ROOF

GAS VALVE

GAS PIPE SUPPORTSTANDARD TYPE

UNION @ CONNECTION

ROOF LINE

DRIP LEG

1'-0" MIN.

GAS-FIRED

EQUIPMENT

SPACING DISTANCE TO EXISTINGROOF DRAIN. RE: ARCH

COORDINATE OPENING INEXISTING ROOF W/ ARCHITECTAND GENERAL CONTRACTOR

NEW CLAMPING RINGRE: SPECS.

EXISTING ROOF SYSTEMRE: ARCH.

ROOF DRAIN CONDUCTOR PIPING.RE: SPECS.

2" HIGH STANDPIPE.RE: SPECS.

OD-1

DRAIN RECEIVER

DRAIN RECEIVER CLIP

EXISTING BALLAST

NEW UNDERDECK CLAMP

MEDIUM PRESSURE GAS,SEE PLAN FOR CONT.

MANUAL GAS VALVE

SERVICE UNION

6" LONG DIRT LEGGAS PRESSURE REGULATOR

(GPR) SEE PLAN AND SCHEDULEFOR REQUIREMENTS

LOW PRESSURE GAS, SEEPLAN FOR CONTINUATION

INCREASER AS REQUIRED

PRESSURE GUAGE

(4) PIPE DIAMETERS

VENT TO ROOF FULL SIZEOF UNIT DISCHARGE W/

GOOSENECK

NOTE: SEE PLAN FOR PIPE

SIZES NOT INDICATED HERE.

2'-0" x 2'-0" x 6" CONCRETERETAINING RING BY P.C.

4" CAST IRONEXTENSION

4" - 45°ELBOW

BEDDING

45° WYEFITTING

SEWER, SEEPLANS CAST IRON SEWER FROM

BUILDING,RE: PLANS

FINISHEDGRADE

FLOW

CLEANOUT COVER, SEEPLUMBING EQUIPMENTSCHEDULE

GCO-1

STANCOR OIL-MINDER 115V, 1∅ CONTROL SYSTEM W/ BUILT IN AUDIBLE AND VISUALALARM WHEN PUMP DOESN'T RUN DUE TO OIL IN PIT, HIGH AMPERAGE OR HIGH

LIQUID CONDITION. PROVIDE SILENCING BUTTON FOR AUDIBLE ALARM BUILT INTOPANEL. PANEL SHALL HAVE ADDITIONAL CONTACT FOR A REMOTE ALARM LOCATION.

ELECTRICALOUTLET

POWERSUPPLY

MULTI-PIN CONNECTOR

MULTI-PIN CONNECTOR & CORD INCONDUIT LENGTHS AS REQUIRED

FLOOR

HIGH LIQUID ALARM FLOAT W/ CLAMP DEVICE TOMOUNT TO PUMP DISCHARGE PIPING

CHECK VALVE

SUMP PIT CAST IN PLACE COOR. W. G.C.

SUMP PUMP

COVER

GATE VALVE

OIL-MINDER POWER CABLE,PROBE CABLE & FLOAT CABLE

JUNCTION BOX PROVIDED W/ MULTI-PINCONNECTOR & CORD IN LENGTHS AS

REQUIRED

MULTI-PIN CONNECTOR

2"PD, SEE PLAN

WATER HAMMER ARRESTOR, SEE PLAN FORDESIGNATION, PROVIDE WITH ACCESSPANEL.

BALL VALVE

FULL SIZE OF SHOCK ABSORBER INLET

REDUCE IN VERTICAL AS INDICATED

WATER SUPPLY TO EQUIPMENT,SEE PLAN AND SCHEDULES

WATER HAMMER ARRESTOR,SEE PLAN FOR DESIGNATION,PROVIDE WITH ACCESS PANEL.

BALL VALVE

REDUCE IN VERTICAL ASINDICATED

WATER SUPPLY TO EQUIPMENT,SEE PLAN AND SCHEDULES

WATER HAMMER ARRESTOR,SEE PLAN FOR DESIGNATION,PROVIDE WITH ACCESS PANEL.

BALL VALVE

FINAL FIXTURE SERVED

CW HEADER WITHIN CHASE, SEEPLAN

WATER SUPPLY ABOVE CEILING, SEE PLAN

S.A. MAY BE POSITIONED ABOVE CEILING

FULL SIZE OF SHOCK ABSORBERINLET

FULL SIZE OF SHOCK ABSORBERINLET

5 PIPE

DIAMETERMINIMUM

BALL VALVE

CHECK VALVE

UNION

NEOPRENE ISOLATED CLAMP

IN-LINE CIRCULATION PUMP,

SEE PLAN FOR DESIGNATION

UNI-STRUT MOUNTED ON WALL

UNION

BALL VALVE

3/4" HWC FROM SYSTEM

(E)BFP

(E)BFP

(E) 3" TO IRRIGATIONWATER SYSTEMRE: PLANS

3" DOMESTIC CW FROMWATER SERVICE MAINRE: PLANS

(E)PRV

(E)PRV

(E)PRV

(E)BYPASS

FINISHED FLOOR

CONNECT NEW 3" CWTO EXSITING 3" CW TOBY-PASS PRV STATIONFOR IRRIGATIONMODIFICATIONS

CONNECT NEW 3" CWTO EXSITING 3"IRRIGATION BACKFLOWDEVICE

REPAIR CONNECTIONTO EXISTINGDOMESTIC BACKFLOWDEVICE

(E) 3" CW TODOMESTIC SYSTEM

(E)BFP

(E)BFP

(E) 3" TO IRRIGATIONWATER SYSTEMRE: PLANS

3" DOMESTIC CW FROMWATER SERVICE MAINRE: PLANS

(E)PRV

(E)PRV

(E)PRV

(E)BYPASS

FINISHED FLOOR

REMOVE EXISTING TEEFOR IRRIGATIONMODIFICATIONS.

(E) 3" CW TODOMESTIC SYSTEM

REMOVE SECTION OFRISER FORIRRIGATIONMODIFICATIONS.

1 CLEVIS HANGER DETAILNOT TO SCALE6 ICE MAKER BOX DETAIL

NOT TO SCALE10 THERMOSTATIC MIXING VALVE DETAILNOT TO SCALE13 WALL CLEANOUT DETAIL

NOT TO SCALE

11 PLASTER TRAP DETAIL (PT-1)NOT TO SCALE

7 ROOF DRAIN DETAILNOT TO SCALE 2 GAS PIPE ROOF PENETRATION DETAIL

NOT TO SCALE

3 ROOFTOP GAS CONNECTION DETAILNOT TO SCALE8 OVERFLOW ROOF DRAIN DETAIL

NOT TO SCALE

4 GAS PRESSURE REGULATOR PIPING DETAILNOT TO SCALE

5 GRADE CLEANOUT - EXTERIORNOT TO SCALE9 ELEVATOR SUMP PUMP DETAIL

NOT TO SCALE12 WATER HAMMER ARRESTOR DETAILSNOT TO SCALE

15 WATER ENTRY DETAIL (NEW)NOT TO SCALE

16 WATER ENTRY DETAIL (DEMO)NOT TO SCALE

14 CIRCULATION PUMP DETAILNOT TO SCALE

ENVIS

ION

MEC

HA

NIC

AL

EN

GIN

EER

S I

NC

.

9777 P

yramid

Court, S

uit

e 1

20

Engle

wood, C

O 8

0112

Tel-

303-6

88-0

223

Fax- 303-6

88-3

584

envis

ionengrs.c

om

Proje

ct #

Date

Drawn By

Checked By:

Project Number

Sheet Name

Copyright:

ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE

DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF

MOA ARCHITECTURE

NOT FOR

CONSTRUCTION

AD

DIT

ION

S A

ND

RE

NO

VA

TIO

NS

016-0

09

7/29

/201

6 10

:38:

50 A

M

P-500

PLUMBINGDETAILS

SIE

RR

A E

LE

ME

NT

AR

Y S

CH

OO

L

JJR

08.04.16

16100.00

7771

Oak

St.

Arv

ada,

CO

800

05

BID SET

JCF

REVISION DATE

lmedina
Ellipse