4
Touch, Near Contact & Non-Contact Enucleation End- ring Fiber Ablation Side- ring Fiber CONVERGENT LASER TECHNOLOGIES Diode Laser System A Soft Tissue Laser For All Techniques ! ProTouch Laser System for BPH www.convergentlaser.com

FINAL- 3.9.15 - Surgical and Laser Equipment Solutionswehnever.com/pdfs/Convergent_1470protouch.pdfThe Optimum Diode Laser Wavelength for Treatment of Soft Tissue and BPH The T-1470

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: FINAL- 3.9.15 - Surgical and Laser Equipment Solutionswehnever.com/pdfs/Convergent_1470protouch.pdfThe Optimum Diode Laser Wavelength for Treatment of Soft Tissue and BPH The T-1470

Touch, Near Contact & Non-Contact

EnucleationEnd-firing Fiber

AblationSide-firing Fiber

CONVERGENT LASER TECHNOLOGIES

Diode Laser System

A Soft Tissue Laser For All Techniques !

ProTouchLaser System for BPH

w w w . c o n v e r g e n t l a s e r . c o m

Page 2: FINAL- 3.9.15 - Surgical and Laser Equipment Solutionswehnever.com/pdfs/Convergent_1470protouch.pdfThe Optimum Diode Laser Wavelength for Treatment of Soft Tissue and BPH The T-1470

Ablation and Coagulation Effect Comparisons

The T-1470 ProTouch effectively ablates tissue and leaves a controlled zone of necrosis to seal off tissue surface with minimal post-operative irritation symptoms.

The Optimum Diode Laser Wavelength for Treatment of Soft Tissue and BPH

The T-1470 ProTouch Surgical Laser System combines the optimum absorption characteristics of the 1470nm laser wavelength with the proprietary laser power control system technology to offer the best surgical laser tool for most sof t t issue cl inical appl icat ions. The combinat ion of high absorbent efficiency in water, oxyhemoglobin, and lipids at 1470nm wavelength makes the T-1470 ProTouch the most effect ive and hemostatic cutting tool delivered through flexible fiberoptics. The patented and proprietary SuperPulse control settings further enhance the ability of the T-1470 ProTouch to adapt to a variety of open and endoscopic surgical techniques.

0 mm

5 mm

4 mm

1 mm

532nmKTP

2100nmHolmium

980nmDiode

T-1470Diode

Zone of Thermal Necrosis

Zone of Ablation

Sample Zones of Penetration10 mm

1600nm 1800nm 2100nm532nm 800nm 1000nm 1200nm 1400nm

0.0001

0.10

10.00

1,000.00

0.001

0.01

1.00

100.00

KTP/532nm Diode/980nm Diode/1470nm Thulium/Holmium

Water

Oxyhemoglobin

980

Ab

sorp

tio

n C

oeffi

cien

t

(1/c

m)

Fat/Lipids

T-1470

T-1470

532

Eric J. Sacknoff, M.D., F.A.C.S. Assistant Clinical ProfessorHarvard Medical School Smyth County Community Hospital

“ The T-1470 ProTouch Diode laser is a clinically unique new laser. After 30 yearsexperience using multiple wavelengths in urologic laser surger y, I found the T-1470 ProTouch laser provides excellentvaporization and coagulation for resection of prostate tissue, bladder tumors, bladderneck contractures, urethral strictures, andexcis ion of peni le neoplasms. Af ter completing over 32 cases I have been impressed with this laser’s efficacy andminimal side effects. This cost effectivelaser uses standard 110 volt current andweighs only 55 pounds. This unit i s significantly smaller than its competitorswhile delivering remarkably complete lasertissue interaction.”

“The T-1470 laser allows the surgeon to enucleate prostate tissue similar to the high-powered holmium laser but with better coagulation than the holmium laser. The ablative properties of the T-1470 laser are superior to the holmium laser and comparable to the KTP laser. The T-1470 laser may also help surgeons transition from ablative technique to enucleation techniques. The T-1470 laser should prove to be an impor tant tool in the laser management of BPH.”

Akhil K. Das, M.D., F.A.C.S. Assistant Professor Thomas Jefferson University Hospital

“It’s like a “Bovie” on a tip of a laser fiber,only it coagulates better with less unwantedcollateral tissue damage. The huge advantageof this laser is that it allows urologists toperform surgery without bleeding-enablinga clear field and controlled operation.”

Paul M. Arnold, M.D., F.A.C.S. Chief of StaffFlorida Hospital North PinellasUrology Specialists of West Florida

532

2100

2100

Page 3: FINAL- 3.9.15 - Surgical and Laser Equipment Solutionswehnever.com/pdfs/Convergent_1470protouch.pdfThe Optimum Diode Laser Wavelength for Treatment of Soft Tissue and BPH The T-1470

Post-OperativePre-Operative

CONVERGENT LASER TECHNOLOGIES

Diode Laser System

Innovative TechnologyThe T-1470 ProTouch laser system is the latest in Cutting Edge Laser Technologyfor the Treatment of Symptomatic BPH and has been demonstrated to controlbleeding and improve patient outcome.

Advantages of T-1470 ProTouch™

* Ambient Beam Sensing Stray beam monitoring to protect operating room personnel

* SuperPulse Technology Resting time between high peak power pulses enhances precision * Most Effective Laser Wavelength for Hemostasis Proper combination of absorption coefficients for high vessel sealing strength

* Powerful and Fast A powerful 100 Watt laser that works precisely and efficiently

* Lightweight and Compact 55 pounds and powered by a standard 110 VAC wall outlet

* High Water and Fat Absorptions Safer cutting and coagulation with shallow thermal necrosis

* Real-Time Temperature Monitoring Fiber tip temperature monitoring for treatment control

“This extremely versatile and hemostatic laser energy is optimally suited for BPH adenoma enucleation, however it can bejust as valuable and performing partial nephrectomy and cr it ical aspects of minilap open radical prostatectomy.”

Frazier T. Fortenberry Jr., M.D.UrologistMartha Jefferson HospitalUniversity of Virginia Medical Center

“The shallow depth of penetration of theProTouch prevents injury to the nerveendings and very reliably preserves sexualpotency. It enucleates tissue circumferentiallyin a very comfortable fashion and allowsthorough opening of the prostatic urethra.The end result has been as good as asuprapubic prostatectomy.”

James E. Rotolo, M.D., F.A.C.S. Chief of UrologyOcean Medical Center

“Patients have been very pleased with the Transurethral Laser Enucleation of the Prostate (TLEP). The ProTouch provides a u n i q u e c o m b i n a t i o n o f t h o r o u g h enucleation, low risk and rapid recovery. Quality of life is markedly improved while protecting and preserving bladder and renal function.”

Charles Seabury, M.D.UrologistVirginia UrologyVirginia Urology Center

“Due to its thorough hemostatis, utilizatingthe ProTouch 1470 in the surgery centersetting allows me to confidently dischargethe patients with less concern for post-procedure bleeding. It is user friendly, requiring only a standard 110V outlet, instead of special plugs. With both resection and vaporization capacity, it allows surgeons to easily obtain pathology specimen if desired.”

Page 4: FINAL- 3.9.15 - Surgical and Laser Equipment Solutionswehnever.com/pdfs/Convergent_1470protouch.pdfThe Optimum Diode Laser Wavelength for Treatment of Soft Tissue and BPH The T-1470

© 2015 Convergent Laser Technologies. All rights reserved. Printed in U.S.A.

CONVERGENTL A S E R T E C H N O L O G I E S

1660 South Loop Road, Alameda, CA 94502

E - m a i l : i n fo @ c o nve rg e n t l a s e r. c o mWebsite: www.convergentlaser.com

Made in theUSA

CLASS IV LASER PRODUCT

180W MAX 975nm100W MAX1470nm

LASER RADIATION---AVOID EYE OR SKINEXPOSURE TO DIRECT OR SCATTERED

VISIBLE AND INVISIBLE RADIATION

REGISTERED

ISO5

3

84

1

1470nm (Also available in 980nm)

Diode Laser, 635nm (red) or 532nm (green)

ProTouch 100 Watts

110 VAC, 20 Amps, 50/60 Hz

Thermo-Electric. No water required

55°F (13° C) - 85°F (30°C)

50°F (10°C) - 104°F (40°C)

W16” (40.6 cm), D24” (61 cm), Hx” (33 cm)

55 lbs (25 kg)

Diode, SuperPulsed and Continuous Wave

Wavelength

Aiming Beam

Maximum Average Power

Electrical Requirement

Cooling

Operating Temperature

Storage Temperature

Dimensions

Weight

Laser Type

Features & specifications subject to change without prior notice. Document Number: 211184-01

Specifications

1470nm

635nm (red)

100 Watts

110 VAC

Air Cool. No water required

55°F (13° C) - 85°F (30°C)

50°F (10°C) - 104°F (40°C)

16” W (41cm) x 24” D (61 cm) x 14“ H (36 cm)

55 lbs (25 kg)

Continuous, Pulse, SuperPulse

Wavelength

Aiming Beam

Maximum Average Power

Electrical Requirement

Cooling

Operating Temperature

Storage Temperature

Dimensions

Weight

Laser Modes

ProTouch™

onvergent Laser Technologies is dedicated to the development of advance medical lasersystems for cardiovascular, general surgical, dental, aesthetic, ENT, GI, GYN and urologicalapplications. Convergent laser systems are especially designed to be highly efficient, stable, reliable, and user-friendly by utilizing its proprietary control systems to be lighter, more compact and requires less electrical power compared to other medical lasers.

The Odyssey product line is the leading stone management lithotripsy laser that is soldworldwide and well acknowledged as the premium holmium laser lithotripsy system. The newT-1470 ProTouch is the multi-specialty laser system designed to be the perfect complementfor treating soft tissue indications.

The entire Convergent team of highly skilled engineers, technicians, customer support and field sales personnel are committed to excellence in quality and service as mandated by its company founders. All Convergent products are proudly designed and manufactured in the USA.

C