12
12.573 12.573 4.888 40.248 5.955 12.573 12.573 40.234 40.234 40.234 234°57'20" 234°57'20" 234°57'20" 323°26'10" 54°57'20" 54°57'20" 54°57'20" 144°57'20" 144°57'20" 144°57'20" 2 RP619288 3 RP602024 1 RP602024 GEORGE LANE 338 (From Records) EHWS Elec Box SL 9.3 (From Records) (From Records) (From Records) SW SW Pit SL 9.45 Kb KbO IL 9.23 9.27 9.37 12.22 12.4 12.39 8 59 9.33 9.25 9.25 9.25 9.09 9.11 9.2 9.22 9.18 9.05 9.18 9.04 9.1 9.08 9.03 9.21 9.27 9.25 9.25 9.17 9.23 9.34 9.29 9.29 9.34 9.36 9.43 9.36 9.44 9.41 9.4 9.51 9.52 9.56 9.49 9.38 9.4 9.46 9.47 9.4 9.49 9.48 9.32 9.36 9.29 9.32 9.48 9.48 9.48 9 . 2 9 9 . 2 1 11.77 1 2 . 2 1 12.29 12.49 12.4 8.84 8.71 8 8.66 8.78 8.7 8.72 8.79 8.67 8 8 64 8.77 9 9.21 9 9.04 9 8.96 8.71 8.71 8.69 8.67 8.98 8.95 8.97 9.08 9.05 9.08 9.18 9.16 9.18 9.2 9.18 9.18 9.21 9.27 9.27 9.27 9.36 9.39 9 9 9.34 9.25 9.12 8.93 8.94 8.89 8.88 8.74 8.94 8.98 9.02 9.04 8.98 9.09 8.94 9.06 9.09 9.13 9.18 9.01 9.17 9.21 9.2 9.2 9.52 9.51 9.28 Steps Conc Path c P a t h Conc Spoon Drain Drain veway FL 9.48 FL 9.59 Conc Kerb & Channel Gate Gate Gate GI Shed on FL9.51 Conc Slab Lowset Brick Building FL 9.48/FL9.59 Lowset Block Retail Building FL9.44 G r a s s V e r g e Vacant Land Sew MH SL 9.30 Sew MH SL 9.16 IL 7.61 I L 7 . 5 7 IL 8.51 100 50 1 5 0 Sew IO SL 9.29 Sew IO x 2 SL 9.35 Records) (From Records) (Unable to open) EXISTING TREES TO BE REMOVED SHOWN DASHED EXISTING SHED TO BE DEMOLISHED SHOWN DASHED PROPOSE NEW LOCATION OF SEWERAGE LINE APPROX. SHOWN BLUE EXISTING BUILDING TO BE DEMOLISHED SHOWN DASHED EXISTING TREES TO BE REMOVED SHOWN DASHED S S S S S S S S PROPOSED RELOCATION POSITION OF SEWER MANHOLE PROPOSE TO REMOVE EXISTING SEWERAGE LINE TO NEW LOCATION DENHAM ST OSD TANK BY STORMWATER ENG. DETAILS GENERAL NOTES - DEMOLITION: UNDERTAKE OTHER DEMOLITION WORK AS REQUIRED, IN ORDER TO PRODUCE THE FINAL BUILDING AS ILLUSTRATED IN THESE DRAWINGS DURING DEMOLITION, ENSURE THAT ALL NECESSARY HOARDINGS, SCREENS, PROPPING & PROCEDURES ARE CARRIED OUT, AS REQUIRED UNDER THE WORKPLACE HEALTH & SAFETY ACT AND TO PROVIDE STRUCTURAL ADEQUACY WHERE JUNCTIONS/ ELEMENTS BETWEEN DEMOLISHED AND REMAINING ITEMS AR TO REMAIN, THESE AREAS ARE TO BE MADE GOOD. WHERE PRACTICAL, RETAIN REMOVED MATERIALS FOR RE-USE, PARTICULARLY ITEMS LISTED AS SUCH ON THE DRAWINGS. STORE ITEMS FOR RE-USE AWAY FROM THE ELEMENTS, OR AS APPROPRIATE IF ASBESTOS BASED MATERIALS ARE ENCOUNTERED, SPECIALIST REMOVERS MUST BE ENGAGED, AND ALL OTHER PERSONS REMOVED FROM SITE AND ALL NEIGHBOURING PROPERTIES TO BE INFORMED 1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPE AND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE. OWNER / CLIENT DRAWINGS APPROVED APPROVED BY: DATE SIGNATURE DESIGNER PROJECT MANAGER APPROVAL TENDER CONSTRUCTION CHECKED BY: SIGNATURE DATE PRELIMINARY PROJECT & CLIENT JOB NO: DRAWN BY: DATE: CHECKED BY: PROJECT MGR: SCALE @ A3: DRAWING NO: TOTAL PAGES: REV: DRAWING TITLE: File Path: Drawing Plotted: L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 099 [email protected] HY CHHENG ABN 80 621 185 064 www.arkexpressdesign.com.au NOMINATED ARCHITECT NSW 8921 - VIC 19176 - QLD 5464 As indicated 11.06.2019 A H:\Temp Job Folder - Work from home\19.06.11 Rockhampton\112-114 Denham St, Rockhampton City - DA 02.rvt 11/06/2019 9:09:44 AM DR NICHOLAS MANNING A0001 112-114 DENHAM ST, ROCKHAMPTON CITY QLD 4700 LOT 1&3 SP602024 & LOT 2 SP619288 1191 (19288) SP PROPOSED HEALTH CARE SERVICES HC EXISTING SITE & DEMOLITION PLAN 12 1 : 200 EXISTING SITE & DEMOLITION PLAN 1 REV. DESCRIPTION BY DATE 8 DRAFT DA ISSUE - MINOR CHANGES HC 31.03.2019 9 DRAFT DA ISSUE & CONSULTANT COORDINATION SP 12.04.2019 10 ISSUE TO LANDSCAPE CONSULTANT SP 7.05.2019 11 DRAFT DA ISSUE SP 6.06.2019 A DA ISSUE HC 11.06.2019

File Path: A0001 Drawing Plotted · b L w se t B ri ck B ui di n g F L 9. 4 8/ F L. 5 9 L o w se t Bl c k R et ail B uil di n g F L 9 4 4 G ra s V eg a a nt L a d S e w M H S L 9

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: File Path: A0001 Drawing Plotted · b L w se t B ri ck B ui di n g F L 9. 4 8/ F L. 5 9 L o w se t Bl c k R et ail B uil di n g F L 9 4 4 G ra s V eg a a nt L a d S e w M H S L 9

12.57312.5734.888

40.248

5.955 12.573 12.573

40.23440.234

40.234

234°57'20"234°57'20"

234°57'20"

323°26'10"

54°57'20" 54°57'20" 54°57'20"

144°57'20"

144°57'20"

144°57'20"

2RP619288

3RP602024

1RP602024

GEO

RG

E LANE

338

(From R

ecords)

EHWS

Elec BoxSL 9.3

(From Records)

(From R

ecords)

(From Records)

SW

SW Pit

S L 9.45

Kb Kb O

IL

9.23

9.27

9.37

12.2212.4

12.39

859

9.33

9.25

9.25

9.25

9.09

9.11

9.2

9.22

9.18 9.05

9.18

9.04

9.1

9.089.039.219.27

9.25

9.259.17

9.23

9.349.299.299.349.36

9.439.36

9.449.41

9.4

9.51

9.529.56

9.499.38

9.49.469.479.4

9.49

9.48 9.329.36

9.29

9.32

9.48

9.489.48

9.299.21

11.77

12.2112.29

12.4912.4

8.848.71 88.668.78

8.78.72

8.798.6788 64

8.77

99.21

9

9.04

9

8.96

8.71

8.718.698.67

8.988.958.97

9.089.059.08

9.189.169.18

9.29.189.18

9.21

9.279.279.279.36

9.39 9

9

9.34

9.25

9.12

8.93

8.94

8.898.88

8.74

8.94

8.98

9.02

9.04

8.98

9.09

8.94

9.06

9.09

9.13

9.18

9.01

9.17

9.21

9.2

9.2

9.52

9.51

9.28

Steps

Conc

Path

c Path

Conc S poon D

rainD

rain

ve way

FL 9.48

FL 9.59

Conc Kerb & Channel

Gate

Gate

Gate

GI Shed onFL9.51

Conc Slab

Lowset BrickBuilding

FL9.48/FL9.59

Lowset Block

Retail BuildingFL9.44

Grass Verge

Vacant Land

Sew MHSL 9.30

Sew MHSL 9.16

IL 7. 61

IL 7.57

IL 8.51100

50

150

Sew IO

S L 9.29

Sew IO x 2SL 9.35

Records )

(From R

ecords)

(Unable to open)

EXISTING TREES TO BE REMOVED SHOWN DASHED

EXISTING SHED TO BE DEMOLISHED SHOWN DASHED

PROPOSE NEW LOCATION OF SEWERAGE LINE APPROX. SHOWN BLUE

EXISTING BUILDING TO BE DEMOLISHED SHOWN DASHED

EXISTING TREES TO BE REMOVED SHOWN DASHED

S S S S S

SS

S

PROPOSED RELOCATION POSITION OF SEWER MANHOLE

PROPOSE TO REMOVE EXISTING SEWERAGE LINE TO NEW LOCATION

DENHAM ST

OSD TANK BY STORMWATER ENG. DETAILS

GENERAL NOTES - DEMOLITION:• UNDERTAKE OTHER DEMOLITION WORK AS REQUIRED, IN ORDER

TO PRODUCE THE FINAL BUILDING AS ILLUSTRATED IN THESE DRAWINGS

• DURING DEMOLITION, ENSURE THAT ALL NECESSARY HOARDINGS, SCREENS, PROPPING & PROCEDURES ARE CARRIED OUT, AS REQUIRED UNDER THE WORKPLACE HEALTH & SAFETY ACT AND TO PROVIDE STRUCTURAL ADEQUACY

• WHERE JUNCTIONS/ ELEMENTS BETWEEN DEMOLISHED AND REMAINING ITEMS AR TO REMAIN, THESE AREAS ARE TO BE MADE GOOD.

• WHERE PRACTICAL, RETAIN REMOVED MATERIALS FOR RE-USE, PARTICULARLY ITEMS LISTED AS SUCH ON THE DRAWINGS. STORE ITEMS FOR RE-USE AWAY FROM THE ELEMENTS, OR AS APPROPRIATE

• IF ASBESTOS BASED MATERIALS ARE ENCOUNTERED, SPECIALIST REMOVERS MUST BE ENGAGED, AND ALL OTHER PERSONS REMOVED FROM SITE AND ALL NEIGHBOURING PROPERTIES TO BE INFORMED

1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.

OWNER / CLIENT

DRAWINGS APPROVED

APPROVED BY: DATE SIGNATURE

DESIGNER

PROJECT MANAGER

APPROVAL TENDER CONSTRUCTION

CHECKED BY: SIGNATUREDATE

PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:

DATE:CHECKED BY:

PROJECT MGR: SCALE @ A3: DRAWING NO:

TOTAL PAGES:

REV:DRAWING TITLE:

File

Path

:Dr

awing

Plot

ted:

L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG

ABN 80 621 185 064

www.arkexpressdesign.com.au

NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464

As indicated

11.06.2019

A

H:\T

emp J

ob F

older

- W

ork f

rom

home

\19.06

.11 R

ockh

ampto

n\112

-114

Den

ham

St, R

ockh

ampto

n City

- DA

02.rv

t11

/06/20

19 9:

09:44

AM

DR NICHOLAS MANNING

A0001

112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288

1191 (19288)SPPROPOSED HEALTHCARE SERVICES

HC

EXISTING SITE &DEMOLITION PLAN

12

1 : 200

EXISTING SITE & DEMOLITION PLAN1

REV. DESCRIPTION BY DATE8 DRAFT DA ISSUE - MINOR

CHANGESHC 31.03.2019

9 DRAFT DA ISSUE & CONSULTANTCOORDINATION

SP 12.04.2019

10 ISSUE TO LANDSCAPECONSULTANT

SP 7.05.2019

11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019

mcdonaldk
New Stamp
Page 2: File Path: A0001 Drawing Plotted · b L w se t B ri ck B ui di n g F L 9. 4 8/ F L. 5 9 L o w se t Bl c k R et ail B uil di n g F L 9 4 4 G ra s V eg a a nt L a d S e w M H S L 9

EOEOEOEOEUEUEUEUFOFOFOFOGGGGSSSS

SWSWSWSWTTTTWWWW

EXISTING TREES TO BE DEMOLISHED SHOWN DASHED

PROPOSED MEDICAL CENTREAREA: 400m²

SHARED ZONE

0209 08 07 06 05 04 03

2400 2600 2600 2700 2600 2600 2600 2600 2600 2600

01

10

11

5800

EXISTING BUILDING TO BE DEMOLISHED SHOWN DASHED

1000

2600 24005400

TURNINGBAY

DR SPACE(COVERED)

+S.F.L RL: 9.450

+S.F.L RL: 9.465

2400

5400

5400

3000 x 3000 PROHIBITED PLANTING AREA TO ALLOW FOR SAFE ENTRY AND EXIT FROM GEORGES LANE SHOWN HATCHED

PROPOSE NEW LOCATION OF SEWERAGE LINE APPROX. SHOWN BLUE

BIN

STO

RAG

E AR

EA

PROPOSED 1600mm HIGH SANDSTONE PIER AND "LEVEL SPEAR" FENCE TO PRIMARY AND SECONDARY BOUNDARIES FOR SAFETY AND VISIBILITY WITH AUTOMATED SLIDING "LEVEL SPEAR" GATE AT PATIO AND DRIVEWAY ENTRIES

1200

1700

1269

8

6298

1162

S S S S S

SS

S

PROPOSED RELOCATION POSITION OF SEWER MANHOLE

PROPOSED AUTO SECURITY SLIDING GATE

PROPOSED 1600mm HIGH SECURITY AUTO SLIDING GATES

6096

2000L SLIMLINE RAINWATER TANK

2000L SLIMLINE RAINWATER TANK

2802

3401

AREA SHOWN HATCHED TO BE MULCHED

DENHAM ST

PEDESTRIAN ACCESS ENTRY CROSS OVER

ALLOW TO SEAL BITUMEN

LOCATION OF A/C UNIT

PROPOSE TO REMOVE EXISTING SEWERAGE LINE TO NEW LOCATION

+F.F.L. RL: 9.50

METAL AWNING ROOF OVER CARSPACES SHOWN DASHED

OSD TANK BY STORMWATER ENG. DETAILS

PROPOSED STORMWATER PITS TO STORMWATER ENGINEER'S DETAILS.

DEVELOPMENT CALCULATION:SITE AREA

LOT 1LOT 2LOT 3TOTAL SITE AREA

SITE COVER & LANDSCAPE CALCULATION

MAXIMUM SITE COVERAGE (80%)

PROPOSED SITE COVER AREA PROPOSED LANDSCAPED AREA

PROPOSED MEDICAL CENTRE (incl. medical rooms, waiting area, garage & wet areas)PROPOSED MEDICAL CENTRE(excl. waiting area, garage & wet areas)

= 218m²= 506m²= 506m²= 1230m²

= 983.88m²

= 449m² COMPLIES= 223.79m² COMPLIES

= 449m²

= 300m²

SETBACKS

FRONT SETBACK(avg. front setback)SIDE SETBACK GROUND FLOORREAR SETBACK

HEIGHT RESTRICTION 12m MAX.

= 3.50m COMPLIES

= 2.7 & 5.50m COMPLIES= 14.2m COMPLIES

= 5.83m COMPLIES

ELECTRICITY OVERHEADELECTRICITY UNDERGROUNDFIBRE OPTICGASSEWERSTORMWATERTELSTRAWATER

SERVICES LEGEND:

TERMITE NOTE:ALL TERMITE PROTECTION TO BE IN ACCORDANCE WITH AS 3660. GRANITGUARD OR SIMILAR AS PER MANUFACTURERS SPECIFICATION.

1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.

OWNER / CLIENT

DRAWINGS APPROVED

APPROVED BY: DATE SIGNATURE

DESIGNER

PROJECT MANAGER

APPROVAL TENDER CONSTRUCTION

CHECKED BY: SIGNATUREDATE

PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:

DATE:CHECKED BY:

PROJECT MGR: SCALE @ A3: DRAWING NO:

TOTAL PAGES:

REV:DRAWING TITLE:

File

Path

:Dr

awing

Plot

ted:

L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG

ABN 80 621 185 064

www.arkexpressdesign.com.au

NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464

As indicated

11.06.2019

A

H:\T

emp J

ob F

older

- W

ork f

rom

home

\19.06

.11 R

ockh

ampto

n\112

-114

Den

ham

St, R

ockh

ampto

n City

- DA

02. rv

t11

/06/20

19 9:

09:48

AM

DR NICHOLAS MANNING

A0002

112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288

1191 (19288)SPPROPOSED HEALTHCARE SERVICES

HC

PROPOSED SITE PLAN

12

1 : 200

PROPOSED SITE PLAN1

REV. DESCRIPTION BY DATE8 DRAFT DA ISSUE - MINOR

CHANGESHC 31.03.2019

9 DRAFT DA ISSUE & CONSULTANTCOORDINATION

SP 12.04.2019

10 ISSUE TO LANDSCAPECONSULTANT

SP 7.05.2019

11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019

mcdonaldk
New Stamp
Page 3: File Path: A0001 Drawing Plotted · b L w se t B ri ck B ui di n g F L 9. 4 8/ F L. 5 9 L o w se t Bl c k R et ail B uil di n g F L 9 4 4 G ra s V eg a a nt L a d S e w M H S L 9

200

100

- SLOPE LENGHT 50M MAX- SLOPE GRAIDENT 1:2 MAX- DRAINAGE AREA 0.5HA MAX

WIRE OR STEEL MESH

GEOTEXTILE FILTER FABRIC

DISTURBED AREA

UNDISTURBED AREA

min length 15 m

0.2 mmin. width 3 m

berm (0.3 m min. high)

existing roadwaydirected to sediment traprun off from pad

fabricgeotextile

50-75 mmgravel

construction site

SHARED ZONE

0209 08 07 06 05 04 03

01

10

DR SPACE

INSTALL APPROVED EROSION AND SEDIMENT CONTROL BARRIER/FENCE (FULL EXTENT TO BE DETERMINED ON SITE TO ENSURE 100% CAPTURE)

TEMPORARY SITE ENTRY/ EXIT FENCE

WASTE BINS FOR TIMBER. BRICK, TILE, CONCRETE, METAL AND MIXED WASTE

STOCKPILING OF "STRIPPED" TOP SOIL AND EXCAVATED MATERIAL TO BE ADEQUATELY PROTECTED WITH GEOTEXTILE MATERIAL. SILT FENCES SHOULD BE PROVIDED IF ASSISTANCE IS NEEDED IN CONTAINING AND SEPARATED STOCKPILES

DENHAM ST

PROPOSED FILL TO 310mm BELOW F.L. 9.50m

PROPOSED FILL TO 310mm BELOW F.L. 9.45m

PROPOSED FILL TO 310mm BELOW F.L. 9.465m

ABBREVIATION:AJ ARTICULATION JOINTBSN BASINDP DOWNPIPESFW FLOOR WASTEHP HOT PLATERH RANGEHOODREF REFRIGERATORSHR SHOWERTUB LAUNDRY TUBVB VANITY BASINWC WATER CLOSETWM WASHING MACHINESD SMOKE DETECTOR

HARDWIRED TO MAINTRH TOILET ROLL HOLDERDTR DOUBLE TOWEL RAILTH TOWEL HOOKMH MAN HOLE

SEDIMENT RUN-OFF CONTROL DURING EARTHWORKS:THE CONTRACTOR SHALL INSTALL AND MAINTAIN SOIL EROSION AND SEDIMENT CONTROL MEASURES GENERALLY IN ACCORDANCE WITH GUIDELINES OF THE NEW SOUTH WALES SOIL CONSERVATION SERVICE AND AS NESASSARY TO PREVENT RUN OFF FROM THE SITE OF ANY SEDIMENT RESULTING FROM HIS WORKS ALL MEASURES ARE TO COMPLY WITH THE REQUIREMENTS OF THE APPROVING COUNCIL TRUCKS AND VEHICLES LEAVING THE SITE ARE NOT TO SPREAD SPOIL ONTO THE ROADWAY OR ALLOW SPOIL TO ENTER THE STORMWATER SYSTEM. ALL DISTURBED GROUND AREAS AND STOCKPILES OF EXCAVATED OR IMPORTED MATERIAL IS TO BE STABILIZED WITHIN 48 HOURS. DUST IS TO BE SUPPRESSED BY WATERING

WASTE LEGEND:BRICK,TILE,CONCRETE DISPOSAL BIN 3 CUBIC METRESTIMBER DISPOSAL BIN 3 CUBIC METRES

MIXED WASTE DISPOSAL BIN 3 CUBIC METRESMETALS DISPOSAL BIN 3 CUBIC METRES

1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.

OWNER / CLIENT

DRAWINGS APPROVED

APPROVED BY: DATE SIGNATURE

DESIGNER

PROJECT MANAGER

APPROVAL TENDER CONSTRUCTION

CHECKED BY: SIGNATUREDATE

PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:

DATE:CHECKED BY:

PROJECT MGR: SCALE @ A3: DRAWING NO:

TOTAL PAGES:

REV:DRAWING TITLE:

File

Path

:Dr

awing

Plot

ted:

L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG

ABN 80 621 185 064

www.arkexpressdesign.com.au

NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464

As indicated

11.06.2019

A

H:\T

emp J

ob F

older

- W

ork f

rom

home

\19.06

.11 R

ockh

ampto

n\112

-114

Den

ham

St, R

ockh

ampto

n City

- DA

02. rv

t11

/06/20

19 9:

09:51

AM

DR NICHOLAS MANNING

A0003

112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288

1191 (19288)SPPROPOSED HEALTHCARE SERVICES

HC

PROPOSED CUT & FILL,WASTE & SITEMANAGEMENT PLAN(DURINGCONSTRUCTION)

12

1 : 200

PROPOSED CUT & FILL, WASTE & SITE MANAGEMENT PLAN - DURINGCONSTRUCTION

1REV. DESCRIPTION BY DATE

8 DRAFT DA ISSUE - MINORCHANGES

HC 31.03.2019

9 DRAFT DA ISSUE & CONSULTANTCOORDINATION

SP 12.04.2019

10 ISSUE TO LANDSCAPECONSULTANT

SP 7.05.2019

11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019

mcdonaldk
New Stamp
Page 4: File Path: A0001 Drawing Plotted · b L w se t B ri ck B ui di n g F L 9. 4 8/ F L. 5 9 L o w se t Bl c k R et ail B uil di n g F L 9 4 4 G ra s V eg a a nt L a d S e w M H S L 9

SHARED ZONE

0209 08 07 06 05 04 03

01

10

11

3500

TURNINGBAY

DR SPACE

+S.F.L RL: 9.450

+S.F.L RL: 9.465

+S.F.L RL: 9.505

BIN

STO

RAG

E AR

EA

S S S S S

SS

S

PROPOSED RELOCATION POSITION OF SEWER MANHOLE

PROPOSE TO REMOVE EXISTING SEWERAGE LINE TO NEW LOCATION

OSD TANK BY STORMWATER ENG. DETAILS

600M TO CBD ROCKHAMPTON

1160M TO ROCKHAMPTON HOSPITAL

PROXIMITY TO PLACES OF SIGNIFICANT:

1000M TO ROCKHAMPTON TRAIN STATION

3400M TO STOCKLAND ROCKHAMPTON SHOPPING CENTRE

WINTER - COLD BREEZE

SPRING - EASTERLY

BREEZE

SUMMER - SOUTH

BREEZE

WINTER SUNSUMMER SUN

SUNRISE

SUNSET

EXIS

TING N

ATURAL

SIT

E FA

LL

DENHAM ST

1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.

OWNER / CLIENT

DRAWINGS APPROVED

APPROVED BY: DATE SIGNATURE

DESIGNER

PROJECT MANAGER

APPROVAL TENDER CONSTRUCTION

CHECKED BY: SIGNATUREDATE

PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:

DATE:CHECKED BY:

PROJECT MGR: SCALE @ A3: DRAWING NO:

TOTAL PAGES:

REV:DRAWING TITLE:

File

Path

:Dr

awing

Plot

ted:

L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG

ABN 80 621 185 064

www.arkexpressdesign.com.au

NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464

1 : 200

11.06.2019

A

H:\T

emp J

ob F

older

- W

ork f

rom

home

\19.06

.11 R

ockh

ampto

n\112

-114

Den

ham

St, R

ockh

ampto

n City

- DA

02. rv

t11

/06/20

19 9:

09:53

AM

DR NICHOLAS MANNING

A0004

112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288

1191 (19288)SPPROPOSED HEALTHCARE SERVICES

HC

PROPOSED SITEANALYSIS

12

1 : 200

PROPOSED SITE ANALYSIS1

REV. DESCRIPTION BY DATE8 DRAFT DA ISSUE - MINOR

CHANGESHC 31.03.2019

9 DRAFT DA ISSUE & CONSULTANTCOORDINATION

SP 12.04.2019

10 ISSUE TO LANDSCAPECONSULTANT

SP 7.05.2019

11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019

mcdonaldk
New Stamp
Page 5: File Path: A0001 Drawing Plotted · b L w se t B ri ck B ui di n g F L 9. 4 8/ F L. 5 9 L o w se t Bl c k R et ail B uil di n g F L 9 4 4 G ra s V eg a a nt L a d S e w M H S L 9

EOEOEOEOEUEUEUEUFOFOFOFOGGGGSSSS

SWSWSWSWTTTTWWWW

1

A3001

1

A3001

DOCTOR'SSPACE

1550

OVE

RAL

L

2403

6

OVERALL

21823

2802

5500

TREATMENT AREAVINYL FINISH5.05 x 15.5m OFFICE

CARPET FINISH3.90 x 4.55m ADMIN

CARPET FINISH2.03 x 4.56m

RECEPTIONCARPET FINISH3.34 x 3.96m

CONS - 2VINYL FINISH4.01 x 4.0m

CONS - 1VINYL FINISH4.01 x 4.0m

STERILISATIONVINYL FINISH3.80 x 3.39m

DIG LABVINYL FINISH1.89 x 1.93m

LABCARPET FINISH2.9 x 4.20m

GARAGE - 2CONC. FINISH2.99 x 6.0m

GARAGE - 1CONC. FINISH3.96 x 6.0m

PLANT ROOM

PROCEDURE/ SURG - 1VINYL FINISH3.90 x 3.90m

SURG - 2VINYL FINISH3.50 x 3.90m

STAFF WCTILE FINISH1.79 x 1.72m

KIDS AREACARPET FINISH4.20 x 2.50m

ACCESSIBLE W.CTILE FINISH2.10 x 2.70m

WCTILE FINISH2.04 x 0.90m

DR'S OFFICECARPET FINISH2.30 x 2.98m

OPG/ CEPHVINYL FINISH1.66 x 1.63m

STAFFVINYL FINISH3.49 x 3.24

WAITING AREAVINYL FINISH4.20 x 9.27m

PATIOTILE FINISH7.93 x 4.26m

SIGN

AGE

KITCHENVINYL FINISH3.60 x 4.77m

7550 11188 3086

2875 2875 2875 2875 2875 7449

1200

5166

1236

853

00

OVE

RAL

L

2403

4

RAM

P 1:

14

3.77 x 1.90m

3.77 x 1.90m

3.77 x 1.90m

3.77 x 1.90m

3.77 x 1.90m

3.77 x 1.90m

BIN

STO

RAG

E AR

EA

+S.F.L RL: 9.465

+RL: 9.45

STORAGE

STORAGE

STO

RAG

E

CUPBOARD

2

A3001

2

A3001

PHOTOWALL (WITH LIGHTBOX)

SCREEN

MAGAZINE RACK

VENDING MACHINE

VENDING MACHINE

1500

mm

H

IGH

WA

LL15

00m

m

HIG

H W

ALL

1500

mm

H

IGH

WA

LL15

00m

m

HIG

H W

ALL

1500

mm

H

IGH

WA

LL

TV

TV

TV

GATE

GATE

A/C UNIT

2,000L R.W.T

2,000L R.W.T

PLANTER

PLANTER

+RL: 9.25

+RL: 9.43

+RL: 9.20+F.F.L. RL: 9.50

1

3710

TERMITE NOTE:ALL TERMITE PROTECTION TO BE IN ACCORDANCE WITH AS 3660. GRANITGUARD OR SIMILAR AS PER MANUFACTURERS SPECIFICATION.

ABBREVIATION:AJ ARTICULATION JOINTBSN BASINDP DOWNPIPESFW FLOOR WASTEHP HOT PLATERH RANGEHOODREF REFRIGERATORSHR SHOWERTUB LAUNDRY TUBVB VANITY BASINWC WATER CLOSETWM WASHING MACHINESD SMOKE DETECTOR

HARDWIRED TO MAINTRH TOILET ROLL HOLDERDTR DOUBLE TOWEL RAILTH TOWEL HOOKMH MAN HOLE

ELECTRICITY OVERHEADELECTRICITY UNDERGROUNDFIBRE OPTICGASSEWERSTORMWATERTELSTRAWATER

SERVICES LEGEND:

1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.

OWNER / CLIENT

DRAWINGS APPROVED

APPROVED BY: DATE SIGNATURE

DESIGNER

PROJECT MANAGER

APPROVAL TENDER CONSTRUCTION

CHECKED BY: SIGNATUREDATE

PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:

DATE:CHECKED BY:

PROJECT MGR: SCALE @ A3: DRAWING NO:

TOTAL PAGES:

REV:DRAWING TITLE:

File

Path

:Dr

awing

Plot

ted:

L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG

ABN 80 621 185 064

www.arkexpressdesign.com.au

NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464

1 : 100

11.06.2019

A

H:\T

emp J

ob F

older

- W

ork f

rom

home

\19.06

.11 R

ockh

ampto

n\112

-114

Den

ham

St, R

ockh

ampto

n City

- DA

02. rv

t11

/06/20

19 9:

10:00

AM

DR NICHOLAS MANNING

A1101

112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288

1191 (19288)SPPROPOSED HEALTHCARE SERVICES

HC

PROPOSED FLOORPLAN

12

REV. DESCRIPTION BY DATE8 DRAFT DA ISSUE - MINOR

CHANGESHC 31.03.2019

9 DRAFT DA ISSUE & CONSULTANTCOORDINATION

SP 12.04.2019

10 ISSUE TO LANDSCAPECONSULTANT

SP 7.05.2019

11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019

mcdonaldk
New Stamp
Page 6: File Path: A0001 Drawing Plotted · b L w se t B ri ck B ui di n g F L 9. 4 8/ F L. 5 9 L o w se t Bl c k R et ail B uil di n g F L 9 4 4 G ra s V eg a a nt L a d S e w M H S L 9

3500

12°

20°

20° 20°

12°12°

SELECTED COLORBOND ROOF SHEETING

SELECTED FASCIA, GUTTER AND DOWNPIPES

METAL AWNING ROOF OVER CARSPACES WITH SELECTED COLORBOND ROOF SHEETING

DENHAM ST

1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.

OWNER / CLIENT

DRAWINGS APPROVED

APPROVED BY: DATE SIGNATURE

DESIGNER

PROJECT MANAGER

APPROVAL TENDER CONSTRUCTION

CHECKED BY: SIGNATUREDATE

PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:

DATE:CHECKED BY:

PROJECT MGR: SCALE @ A3: DRAWING NO:

TOTAL PAGES:

REV:DRAWING TITLE:

File

Path

:Dr

awing

Plot

ted:

L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG

ABN 80 621 185 064

www.arkexpressdesign.com.au

NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464

1 : 200

11.06.2019

A

H:\T

emp J

ob F

older

- W

ork f

rom

home

\19.06

.11 R

ockh

ampto

n\112

-114

Den

ham

St, R

ockh

ampto

n City

- DA

02. rv

t11

/06/20

19 9:

10:02

AM

DR NICHOLAS MANNING

A1102

112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288

1191 (19288)SPPROPOSED HEALTHCARE SERVICES

HC

PROPOSED ROOF PLAN

12

1 : 200

PROPOSED ROOF PLAN1

REV. DESCRIPTION BY DATE8 DRAFT DA ISSUE - MINOR

CHANGESHC 31.03.2019

9 DRAFT DA ISSUE & CONSULTANTCOORDINATION

SP 12.04.2019

10 ISSUE TO LANDSCAPECONSULTANT

SP 7.05.2019

11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019

mcdonaldk
New Stamp
Page 7: File Path: A0001 Drawing Plotted · b L w se t B ri ck B ui di n g F L 9. 4 8/ F L. 5 9 L o w se t Bl c k R et ail B uil di n g F L 9 4 4 G ra s V eg a a nt L a d S e w M H S L 9

DOCTOR'SSPACE

SIGN

AGE

+S.F.L RL: 9.505

+S.F.L RL: 9.465

+RL: 9.45

12

12

STORAGE

STORAGE

STO

RAG

E

CUPBOARD

AREA CALCULATION:

PROPOSED MEDICAL AREA 300m²

PROPOSED WET AREAS 12.5m²

PROPOSED WAITING AREA 85.3m²

TOTAL 449m²

PROPOSED GARAGE & PLANT 51.2m²

1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.

OWNER / CLIENT

DRAWINGS APPROVED

APPROVED BY: DATE SIGNATURE

DESIGNER

PROJECT MANAGER

APPROVAL TENDER CONSTRUCTION

CHECKED BY: SIGNATUREDATE

PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:

DATE:CHECKED BY:

PROJECT MGR: SCALE @ A3: DRAWING NO:

TOTAL PAGES:

REV:DRAWING TITLE:

File

Path

:Dr

awing

Plot

ted:

L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG

ABN 80 621 185 064

www.arkexpressdesign.com.au

NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464

1 : 100

11.06.2019

A

H:\T

emp J

ob F

older

- W

ork f

rom

home

\19.06

.11 R

ockh

ampto

n\112

-114

Den

ham

St, R

ockh

ampto

n City

- DA

02. rv

t11

/06/20

19 9:

10:08

AM

DR NICHOLAS MANNING

A1103

112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288

1191 (19288)SPPROPOSED HEALTHCARE SERVICES

HC

AREA DIAGRAM

12

1 : 100

AREA DIAGRAM1

REV. DESCRIPTION BY DATE9 DRAFT DA ISSUE & CONSULTANT

COORDINATIONSP 12.04.2019

10 ISSUE TO LANDSCAPECONSULTANT

SP 7.05.2019

11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019

mcdonaldk
New Stamp
Page 8: File Path: A0001 Drawing Plotted · b L w se t B ri ck B ui di n g F L 9. 4 8/ F L. 5 9 L o w se t Bl c k R et ail B uil di n g F L 9 4 4 G ra s V eg a a nt L a d S e w M H S L 9

GROUND FLOOR

9.50

GF CEILING

12.60

BOU

ND

ARY

BOU

ND

ARY

RIDGE RL: 14.91

RIDGE RL: 14.06

SELECTED 540x300 AND 340x300(ALTERNATE) SANDSTONE QUOIN

SELECTED EXTERNAL TIMBERHORIZONTAL CLADDING

SELECTED COLORBOND ROOF SHEETING

SELECTED 'LEVEL SPEAR' ANDSANDSTONE PIER FENCE AND SLIDINGGATE TO PATIO AND DRIVEWAY ENTRIES

TIMBER POSTS WITH SELECTED PAINTFINISH AND FINIALS SELECTED ALUMINIUM POWDERCOATED

FRAMED WINDOWSSELECTED TIMBER FRAMED DOOR ANDGLAZED WINDOWS

SELECTED FACEBRICK

SELECTED METAL FASCIA AND GUTTERS

OVE

RAL

L BU

ILD

ING

HEI

GH

T

5413

PROPOSED 1600mm HIGH AUTO SLIDING GATES

3100

MEDICAL CENTRE SIGNAGE

GROUND FLOOR

9.50

GF CEILING

12.60

3100

BOU

ND

ARY

BOU

ND

ARY

2450

SELECTED 'LEVEL SPEAR' ANDSANDSTONE PIER FENCE AND SLIDINGGATE TO PATIO AND DRIVEWAY ENTRIES

TIMBER POSTS WITH SELECTED PAINTFINISH AND FINIALS

SELECTED COLORBOND ROOF SHEETING

SELECTED METAL FASCIA AND GUTTERS

SELECTED 540x300 AND 340x300(ALTERNATE) SANDSTONE QUOINSELECTED ALUMINIUM POWDERCOATED

HIGHLIGHT WINDOWSELECTED ALUMINIUM POWDERCOATEDFRAMED WINDOWS

RIDGE RL: 14.91

RIDGE RL: 14.06SELECTED EXTERNAL TIMBERHORIZONTAL CLADDING

SELECTED FACEBRICK

1411

PROPOSED 1600mm HIGH AUTO SLIDING GATE

METAL AWNING ROOF OVER CARSPACES

CARPORT

1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.

OWNER / CLIENT

DRAWINGS APPROVED

APPROVED BY: DATE SIGNATURE

DESIGNER

PROJECT MANAGER

APPROVAL TENDER CONSTRUCTION

CHECKED BY: SIGNATUREDATE

PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:

DATE:CHECKED BY:

PROJECT MGR: SCALE @ A3: DRAWING NO:

TOTAL PAGES:

REV:DRAWING TITLE:

File

Path

:Dr

awing

Plot

ted:

L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG

ABN 80 621 185 064

www.arkexpressdesign.com.au

NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464

1 : 100

11.06.2019

A

H:\T

emp J

ob F

older

- W

ork f

rom

home

\19.06

.11 R

ockh

ampto

n\112

-114

Den

ham

St, R

ockh

ampto

n City

- DA

02. rv

t11

/06/20

19 9:

10:18

AM

DR NICHOLAS MANNING

A2001

112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288

1191 (19288)SPPROPOSED HEALTHCARE SERVICES

HC

ELEVATIONS 1

12

1 : 100

SOUTH EAST ELEVATION1

1 : 100

NORTH EAST ELEVATION2

REV. DESCRIPTION BY DATE8 DRAFT DA ISSUE - MINOR

CHANGESHC 31.03.2019

9 DRAFT DA ISSUE & CONSULTANTCOORDINATION

SP 12.04.2019

10 ISSUE TO LANDSCAPECONSULTANT

SP 7.05.2019

11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019

mcdonaldk
New Stamp
Page 9: File Path: A0001 Drawing Plotted · b L w se t B ri ck B ui di n g F L 9. 4 8/ F L. 5 9 L o w se t Bl c k R et ail B uil di n g F L 9 4 4 G ra s V eg a a nt L a d S e w M H S L 9

GROUND FLOOR

9.50

GF CEILING

12.60

3100

BOU

ND

ARY

BOU

ND

ARY

RIDGE RL: 14.91RIDGE RL: 14.74

RIDGE RL: 14.06

RIDGE RL: 12.65

RIDGE RL: 13.55

OVE

RAL

L BU

ILD

ING

HEI

GH

T

5433

SELECTED 540x300 AND 340x300(ALTERNATE) SANDSTONE QUOIN

SELECTED ALUMINIUM POWDERCOATEDFRAMED WINDOWS

SELECTED 540x300 AND 340x300(ALTERNATE) SANDSTONE QUOIN

SELECTED COLORBOND ROOF SHEETING

SELECTED FACEBRICK

TIMBER POSTS WITH SELECTED PAINTFINISH AND FINIALS

SELECTED EXTERNAL TIMBERHORIZONTAL CLADDING

DOCTOR'S CAR SPACE

2,000L SLIMLINE RAINWATER TANK

2,000L SLIMLINE RAINWATER TANK

CARPORT

METAL AWNING ROOF OVER CARSPACES

GROUND FLOOR

9.50

GF CEILING

12.60

3100

BOU

ND

ARY

BOU

ND

ARY

RIDGE RL: 14.91 RIDGE RL: 14.74

RIDGE RL: 13.55

SELECTED COLORBOND ROOF SHEETING

SELECTED EXTERNAL TIMBERHORIZONTAL CLADDING

SELECTED METAL FASCIA AND GUTTERS

TIMBER POSTS WITH SELECTED PAINTFINISH AND FINIALS

SELECTED 540x300 AND 340x300(ALTERNATE) SANDSTONE QUOIN SELECTED ROLLER PANEL DOOR

SELECTED FACEBRICK

SELECTED ALUMINIUM POWDERCOATEDFRAMED WINDOWS

400MM HIGH SANDSTONE BAND AROUND PERIMETER OF MEDICAL CENTRE

OVE

RAL

L BU

ILD

ING

HEI

GH

T'

5433

DOCTOR'S CAR SPACE

BIN STORE

1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.

OWNER / CLIENT

DRAWINGS APPROVED

APPROVED BY: DATE SIGNATURE

DESIGNER

PROJECT MANAGER

APPROVAL TENDER CONSTRUCTION

CHECKED BY: SIGNATUREDATE

PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:

DATE:CHECKED BY:

PROJECT MGR: SCALE @ A3: DRAWING NO:

TOTAL PAGES:

REV:DRAWING TITLE:

File

Path

:Dr

awing

Plot

ted:

L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG

ABN 80 621 185 064

www.arkexpressdesign.com.au

NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464

1 : 100

11.06.2019

A

H:\T

emp J

ob F

older

- W

ork f

rom

home

\19.06

.11 R

ockh

ampto

n\112

-114

Den

ham

St, R

ockh

ampto

n City

- DA

02. rv

t11

/06/20

19 9:

10:29

AM

DR NICHOLAS MANNING

A2002

112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288

1191 (19288)SPPROPOSED HEALTHCARE SERVICES

HC

ELEVATIONS 2

12

1 : 100

SOUTH WEST ELEVATION2

1 : 100

NORTH WEST ELEVATION1

REV. DESCRIPTION BY DATE8 DRAFT DA ISSUE - MINOR

CHANGESHC 31.03.2019

9 DRAFT DA ISSUE & CONSULTANTCOORDINATION

SP 12.04.2019

10 ISSUE TO LANDSCAPECONSULTANT

SP 7.05.2019

11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019

mcdonaldk
New Stamp
Page 10: File Path: A0001 Drawing Plotted · b L w se t B ri ck B ui di n g F L 9. 4 8/ F L. 5 9 L o w se t Bl c k R et ail B uil di n g F L 9 4 4 G ra s V eg a a nt L a d S e w M H S L 9

GROUND FLOOR

9.50

GF CEILING

12.60

WAITING AREAACCESSIBLE W.C

OPG/ CEPHSTERILISATIONTREATMENT AREA

BOU

ND

ARY

BOU

ND

ARY

RAKED CEILING WITH EXPOSED RAFTERS TO RECEPTION AND WAITING AREA

INTERNAL WALLS LINED WITH 10mm PLASTERBOARD WITH SELECTED PAINT FINISH

250mm EXTERNAL BRICK VENEER WALL CONSTRUCTION

COMPACTED FILL TO STRUCTURAL ENGINEER'S DETAILS SHOWN HATCHED

CONCRETE SLAB AND FOOTINGS TO STRUCTURAL ENGINEER'S DETAILS

TRUSS ROOF CONSTRUCTION TO MANUFACTURER'S SPECIFICATIONS

SELECTED METAL FASCIA AND GUTTERS

SELECTED COLORBOND ROOF SHEETING

CEILING LINING TO UNDERSIDE OF TRUSS BOTTOM CHORD

INSULATION TO EXTERNAL WALLS

INSULATION TO CEILING

3100

TERMITE NOTE:ALL TERMITE PROTECTION TO BE IN ACCORDANCE WITH AS 3660. GRANITGUARD OR SIMILAR AS PER MANUFACTURERS SPECIFICATION.

GROUND FLOOR

9.50

GF CEILING

12.60

WAITING AREAKIDS AREAPATIO

CONCRETE SLAB AND FOOTINGS TO STRUCTURAL ENGINEER'S DETAILS

TRUSS ROOF CONSTRUCTION TO MANUFACTURER'S SPECIFICATIONS

SELECTED COLORBOND ROOF SHEETING

RAKED CEILING WITH EXPOSED RAFTERS TO RECEPTION AND WAITING AREA

20° 20°

COMPACTED FILL SHOWN HATCHED

3100

1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.

OWNER / CLIENT

DRAWINGS APPROVED

APPROVED BY: DATE SIGNATURE

DESIGNER

PROJECT MANAGER

APPROVAL TENDER CONSTRUCTION

CHECKED BY: SIGNATUREDATE

PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:

DATE:CHECKED BY:

PROJECT MGR: SCALE @ A3: DRAWING NO:

TOTAL PAGES:

REV:DRAWING TITLE:

File

Path

:Dr

awing

Plot

ted:

L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG

ABN 80 621 185 064

www.arkexpressdesign.com.au

NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464

1 : 100

11.06.2019

A

H:\T

emp J

ob F

older

- W

ork f

rom

home

\19.06

.11 R

ockh

ampto

n\112

-114

Den

ham

St, R

ockh

ampto

n City

- DA

02. rv

t11

/06/20

19 9:

10:35

AM

DR NICHOLAS MANNING

A3001

112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288

1191 (19288)SPPROPOSED HEALTHCARE SERVICES

HC

SECTIONS

12

1 : 100

SECTION A-A1

1 : 100

SECTION B-B2

REV. DESCRIPTION BY DATE8 DRAFT DA ISSUE - MINOR

CHANGESHC 31.03.2019

9 DRAFT DA ISSUE & CONSULTANTCOORDINATION

SP 12.04.2019

10 ISSUE TO LANDSCAPECONSULTANT

SP 7.05.2019

11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019

mcdonaldk
New Stamp
Page 11: File Path: A0001 Drawing Plotted · b L w se t B ri ck B ui di n g F L 9. 4 8/ F L. 5 9 L o w se t Bl c k R et ail B uil di n g F L 9 4 4 G ra s V eg a a nt L a d S e w M H S L 9

EXTERNAL FINISHES SCHEDULE:

MAIN EXTERNAL WALL - BRICKWORK -AUSTRALCOLOUR: TOPAZ OR SIMILAR

SANDSTONE BAND AND QUOINSCOLOUR: BROWN YELLOW OR SIMILAR

ROOF - COLORBOND STEELCOLOUR: MONUMENT OR SIMILAR

GARAGE DOOR - ALUMINIUM PRESSED METAL - COLORBOND COLOUR: SHALE GREY - PLAIN

FASCIA & DOWNPIPES - ALUMINIUM/ PRESSED METALCOLOUR: BASALT OR SIMILAR

FRONT ENTRY DOOR - TIMBER FRAME WITH GLASS PANELS

GUTTER - COLORBONDCOLOUR: BASALT OR SIMILAR

WINDOW FRAMES - ALUMINIUM -POWDERCOATEDCOLOUR: WHITE OR SIMILAR

POSTS AND FASCIA FINIALS -TIMBERCOLOUR: WHITE OR SIMILAR

GABLE CLADDING - TIMBER COLOUR: OFF WHITE HORIZONTAL CLADDING OR SIMILAR

FENCE PANELLING - LOW SPEAR COLOUR: MONUMENT OR SIMILAR

1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALE 2. ALL DIMENSIONS ARE IN MILLIMETRES 3. ALL DIMENSIONS TO BE VERIFIED ON SITE AND DISCREPANCIES CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 4. ANY DISCREPANCIES BETWEEN DRAWINGS, SCOPEAND/OR SPECIFICATIONS TO BE CLARIFIED WITH THIS OFFICE PRIOR TO CONSTRUCTION 5. NO CLAIM ARISING FROM NEGLECT OF THESE PRECAUTIONS SHALL BE ADMITTED 6. COPYRIGHT REMAINS THE PROPERTY OF THIS OFFICE.

OWNER / CLIENT

DRAWINGS APPROVED

APPROVED BY: DATE SIGNATURE

DESIGNER

PROJECT MANAGER

APPROVAL TENDER CONSTRUCTION

CHECKED BY: SIGNATUREDATE

PRELIMINARYPROJECT & CLIENT JOB NO:DRAWN BY:

DATE:CHECKED BY:

PROJECT MGR: SCALE @ A3: DRAWING NO:

TOTAL PAGES:

REV:DRAWING TITLE:

File

Path

:Dr

awing

Plot

ted:

L1, SUITE 3, 233 CANLEY VALE ROAD CANLEY HTS NSW 2166 0408 646 [email protected] HY CHHENG

ABN 80 621 185 064

www.arkexpressdesign.com.au

NOMINATED ARCHITECT NSW 8921 -VIC 19176 - QLD 5464

1 : 100

11.06.2019

A

H:\T

emp J

ob F

older

- W

ork f

rom

home

\19.06

.11 R

ockh

ampto

n\112

-114

Den

ham

St, R

ockh

ampto

n City

- DA

02. rv

t11

/06/20

19 9:

10:49

AM

DR NICHOLAS MANNING

A7001

112-114 DENHAM ST,ROCKHAMPTON CITY QLD4700 LOT 1&3 SP602024 &LOT 2 SP619288

1191 (19288)SPPROPOSED HEALTHCARE SERVICES

HC

PERSPECTIVES &FINISHES SCHEDULE

12

DENHAM STREET PERSPECTIVE1

GEORGE LANE PERSPECTIVE2

REV. DESCRIPTION BY DATE8 DRAFT DA ISSUE - MINOR

CHANGESHC 31.03.2019

9 DRAFT DA ISSUE & CONSULTANTCOORDINATION

SP 12.04.2019

10 ISSUE TO LANDSCAPECONSULTANT

SP 7.05.2019

11 DRAFT DA ISSUE SP 6.06.2019A DA ISSUE HC 11.06.2019

mcdonaldk
New Stamp
Page 12: File Path: A0001 Drawing Plotted · b L w se t B ri ck B ui di n g F L 9. 4 8/ F L. 5 9 L o w se t Bl c k R et ail B uil di n g F L 9 4 4 G ra s V eg a a nt L a d S e w M H S L 9

Figured dimensions take precedence over those

Copyright of all drawings and documents and of the

Verify all dimensions on site before commencingany work or shop drawings. If any doubt ask.

work executed is vested in the Principal's Consultants.

ARCHITECTSLANDSCAPEASSOCIATESALDERSON +

PROJECT NO.:

DATE:

DRAWING TITLE:

NORTH:

PROJECT:

CLIENT:

scaled.

REV. DATE

SCALE:

DWG NO.: REVISION:

DRAWN:

DETAILS INITIAL

THIS DOCUMENT DESCRIBES THE FULL INTENTOF LANDSCAPE DESIGN.ALDERSON+ ASSOCIATES TAKE NORESPONSIBILITY FOR ANY 'AS CONSTRUCTED'VARIATION FROM THEIR DRAWINGS ANDDOCUMENTS, INCLUDING HARD LANDSCAPING SETOUT AND SOFTLANDSCAPING INSTALLATION.

EMAIL: [email protected]

LISMORE: P.O. BOX 6282 SOUTH LISMORE, NSW 2480PH:040 991 5853 PH:07 4974 1184A.B.N. 72 537 115 625

GLADSTONE: OLD MANY PEAKS SCHOOLBOYNE VALLEY, QLD 4680

A 10.5.2019 ISSUE FOR APPROVALS. DB

112-114 DENHAM STREET, ROCKHAMPTON

DR. N. MANNING

MEDICAL CENTREPROPOSED

909

APRIL 2019

LANDSCAPE

A

1:100 AT A1

909-LCP01

DB

CONCEPT PLAN

21

SHAREDZONE

TURNINGBAY

PROPOSED

PROPOSED AUTOMATIC SECURITY SLIDING GATE

D E N H A M S T .

F.F.L. 9.500

GATE

GATE

A/CUNIT

R.L. 9.250

12.57312.5734.888

40.2 48

5.955 12.573 12.573

40.234

40.234

40.234

234°57'20"234°57'20"234°57'20"

323° 26 '10 "

54°57'20" 54°57'20" 54°57'20"

144°57'20"

144°57'20"

144°57'20"

2RP619288

3RP602024

1RP602024

G E O R G E L A N E

EXISTING PATH

LOW SET BLOCKRETAIL BUILDINGF.L. 9.44

EXISTING GRASSED VERGE

WM

PP

SMH

EXISTING

SMH

RELOCATEDSEWER ACCESS.

PROPOSED RELOCATION OF SEWER LINE- REFER ARCHITECTURAL DOCUMENTS.

EXISTING SEWERAGE LINE TO BE REMOVED.

EXTENSION OF BITUMEN SEALINGTO FENCE LINE AS PER ARCHITECTURALSCHEME.

EXISTING FENCING TO BE REMOVED.

EXTENT OF PROHIBITED PLANTING ZONE FOR TRAFFIC SIGHT LINES (SHOWN HATCHED).PLANTING LIMITED TO LOW HEIGHT HEDGINGAND GROUNDCOVERS.

1600mm H SANDSTONE PIERED FENCEWITH STEEL PICKET INFILL PANELS AS PERARCHITECTURAL SCHEME.

NEWPATHCONC.

RWT

RWT

EXISTING SHED TO BE DEMOLISHED.

MEDICAL CENTREPROPOSED

CAR PORT

ROOF OVER PARKING BAYS AS PERARCHITECTURAL SCHEME.

PROPOSED RELOCATEDSEWER ACCESS.

BINSTORE

F.F.L. 9.465

PATIO

ENTRY

3

UP

STAIR

RAMP(1:14GRAD.)

R.L. 9.200UP

The landscape treatment for the proposed development is directedtowards the establishment of an attractive setting for the built forms,emphasising site integration and amenity.Treatment is fully integrated with storm water requirements and based on water sensitive design principles e.g.: efficient irrigation design, maximising storm water infiltration etc.CPTED principals will be incorporated throughout the

surveillance requirements.The garden layouts are based on simple geometric forms, reflecting the built forms set within. This ensures visual unity, integration and

LANDSCAPE TREATMENT- GENERALLY

Plant arrangements are designed to maximise visual amenity

Plant layering produces simple and easily maintained visual

Planting is designed to reinforce elements of the built form and site

sense of enclosure, establishing focal points and emphasis on elements, providing amenity shade and establishing visual screening.

Plant selection is based on site suitability and longevity, with an emphasis on native plants.

PLANTING APPROACH

landscape.

Shrubs in particular, are selected for hardiness, longevity and according to their ability to retain vigour with periodic pruning to

LEGEND:GRASSED AREA

MULCHED GARDEN BED

BARK MULCH ONLY

CONCRETE PATH

EXISTING TREE / SHRUBTO BE REMOVED.

AMENITY SHADE TREE

SCREENING SHRUBS

GB

BM

SELECT COLOURED, ROCK SALT

Planting of varying heights, to the street frontage softens the built

arrival and visual appeal of the development, and provides a simple spatial definition between public and private space.

for casual surveillance in accordance with CPTED principles.

STREET BOUNDARY ALIGNMENT

form, visually integrates it with the site, enhances the sense of

Low height planting to street frontages maximises opportunities

The provision of shade trees is an integral theme of the proposed

Shade trees are located where possible, adjacent paved areasto reduce heat and glare reflected from these hard surfaces.Shade trees also reduce the amount of heat load on the building.Shade trees further aid the integration of the building by modifyingits scale and acting as a partial visual screen from the surrounding

Shade tree species are carefully selected based on their suitability

AMENITY SHADE

for incorporation around buildings and infrastructure.

The incorporation of densely planted garden beds to boundaries

properties.

SCREEN PLANTING

provides a visual screen between the development and adjoining

This planting can also significantly reduce reflected heat and glare

BM

GB GB GB

GB

GB

GB

GB

GB

GB

GB

GB

GB

GB

GB

GB

TEXTURED CONCRETE.

RR

R

R

R

R

LOW HEIGHT CLIPPED HEDGE

POTTED PLANTING

VINE PLANTINGS TO TRELLIS SCREENINGEXISTING WALL AND PROVIDINGPLEASANT OUTLOOK FROM INTERIOR OFPROPOSED CLINIC.

LOW HEIGHT SHADE TOLERANT PLANTINGSTO FOREGROUND OF TRELLIS.

RAINWATER TANK AS PER ARCHITECTURALSCHEME- MOUNT ON CONCRETE SLAB.

RAINWATER TANK AS PER ARCHITECTURALSCHEME- MOUNT ON CONCRETE SLAB.

LOW HEIGHT CLIPPED HEDGING TO FENCE LINE.HEDGE TO BE KEPT AT SUITABLE HEIGHT TOBLOCK FOREGROUND BUT MAINTAIN VISTAS TOPARK OPPOSITE.

LOW HEIGHT MASS PLANTING BETWEEN HEDGING AND PATH.

NEW PATH

1600mm H SANDSTONE PIERED FENCEWITH STEEL PICKET INFILL PANELS AS PERARCHITECTURAL SCHEME.

EXISTING GRASSED VERGE- TO BE MADE GOODWHERE DISTURBED BY WORKS.

EXISTING PATH

AMENITY SHADE TREE TYP.- EG: Brachychiton acerifolium

LOW HEIGHT CLIPPED HEDGING TO FENCE LINEPARTIALLY RETURNING ALONG GEORGE LANEFRONTAGE.

RAISED PLANTER TYP. AS PER ARCHITECTURALDETAILS.

MASS PLANTED GROUNDCOVERS UNDERLINE OF SHADE TREES.

SCREEN PLANTING TO BOUNDARY.SYZIGIUM SPECIES LIGHTLY PRUNEDTO ENCOURAGE DENSE GROWTH.

EXISTING COLORBOND FENCETO BE RETAINED.

SHADE TREE WITH VERTICAL HEIGHT TO PROVIDE PRIVACYFROM ADJACENT PREMISES(NORTH-WEST OF SITE).

EXISTING FENCE TO BE RETAINED.

PLANTING IN LARGE URNS ORPLANTER BOXES TYP.

TOTAL SITE AREAPROPOSED LANDSCAPED AREA 223.79 Sq.m

1230 Sq.m

SITE DETAILS:

from hard paved surfaces, glazed facades and roofs.

treatment.

landscape.

(attractiveness) and visual coherence.

layout e.g.: articulating entry points and circulation, creating a

maintain shape.

development with species selected being compatible with casual

interest.

ROCK SALT FINISHED COLOURED

EXAMPLE IMAGE.CONCRETE

BRACHYCHITON ACERIFOLIUM(ILLAWARRA FLAME TREE)EXAMPLE IMAGE.

LOW HEIGHT SYZIGIUM HEDGEAND GROUNDCOVERS.EXAMPLE IMAGE.

LOW HEIGHT MASS PLANTINGEXAMPLE IMAGE.

TO FACADE RECESSES.

PLANTER BOXEXAMPLE IMAGE.

(ILLAWARRA FLAME TREE)

AS PER ARCHITECTURAL SCHEME.PARKING

R

UNDERGROUND STORMWATER DETENTION TANK(13000 L) AS PER CIVIL WORKS DETAILS.BARK MULCH OVER PLASTIC SHEETING ONLYTO THIS AREA- ALL PLANTINGS CLEAR OF TANK.

OVER PLASTIC SHEETING.

ALTERNATIVE EXTERNAL 'VIEW' TREATMENT- MURAL TO EXISTING PARTY WALL BY OTHERS.(SHOWN DASHED).SECTION OF TRELLIS NOT INCLUDED TOACCOMMODATE MURAL.

(REFER ALTERNATIVE 'VIEW' TREATMENT ABOVE).

mcdonaldk
New Stamp