Upload
others
View
30
Download
1
Embed Size (px)
Citation preview
FG Wilson Control Systems
www.FGWilson.com
Contents
1002T Analogue Control Panel
FG Wilson DCP-10 and DCP-20 Digital Control Panels
PowerWizard 1.1, 1.1+ and 2.1 Digital Control Panels
PowerWizard Remote Monitoring Options
PowerWizard Remote Monitoring and Control Options
easYgen–2500SynchronisingControlPanel
easYgen–3200SynchronisingControlPanel
easYgenControlPanelOptions–NetBiterFGW200
easYgenControlpanelOptions–I/OExpansionModule
Load Transfer Panels
CTIPanelFeatures
ATIPanelFeatures
Features and Options
Putting You in Control
Whateveryourpowerrequirements,FGWilsoncanprovideacontrolsystemtosuityourneeds.Ourgeneratorsetexperts
designandvalidateFGWilsoncontrolsystemstooptimiseyourgeneratorsetperformanceandputyouincontrol.
AllFGWilsoncontrolpanelsarecompact,versatileandeasytouse.Ourcomprehensiverangeincludeskey-start
analoguecontrolpanelsforstraightforwardfunctionalityandreliability;digitalcontrolpanelssuitableforuseinmains
failureapplications,providingadvancedmetering,protectionanddiagnostics;andthenextgenerationofadvanced
synchronisingpanelswithintegratedloadmanagementcapability,suitableforsynchronisingupto32generatorsets.
Ourrangeofloadtransferpanelsaredesignedtoenhancetheoperationofyourstandbygeneratorsetinconjunctionwith
ourelectroniccontrolpanels,toprovideautomaticcontrolofyourstandbygeneratorsetintheeventofapoweroutage,
24hoursaday,365daysayear.
Formorechallengingpowerrequirements,ourPowerSolutionsTeamisdedicatedtothedesignandproductionof
bespokecontrolsystemstomeetyourindividualneeds,regardlessofcomplexity.
FG Wilson Control Systems
1002T
The1002TControlPanelisequippedwithallthenecessarygeneratorsetinstrumentationandprotectiondevices,whilstprovidingthestraightforwardfunctionalityandreliabilityofakey-startpanel.
1002TAnalogue Control Panel
• Simplifiedmonitoringofgeneratorsetconditionsata glance• Heavyduty,reliableindustrialpushbuttonsandswitches
• Visualindividualwarningandshutdownsthrough LED’s• Universalpictorialfaultlampindicators
Features• Analoguemetering:voltmeter,ammeter,hours-run counter,combinedfrequencyandtachometer• 7positionvoltmeterphaseselectorswitch• 4positionammeterphaseselectorswitch• Preheat(startaidactiveLEDindicator)• DCsupplyfromstartingbatteryprotectedbyMCB’s• Printedcircuitboardassemblies• Multi-pinplugandsocketconnectionsforeaseof servicing• Engineprotectionthroughcriticalshutdowns• ACinstrumentsare90°deflection,flushmounted• ACinstrumentsinaccordancewithIEC60051and 60529,DIN43700and43718,BSEN60051and 61010,UL94
Benefits
FG Wilson DCP-10 and DCP-20
TheFGWilsonDCPrangeallowsyoutomonitorandcontrolyourgeneratorsetwithease,providingimportantdiagnosticinformationwhilstensuringyourunitoperateswithinsafeparameters.
FGWilsonDCPdigitalcontrolpanels,providesimple, intuitivemenunavigationandcontrolofyourgenerator setoperations.KeyinformationisdisplayedviatheLCDscreenandLED’susinguniversallyrecognisedsymbols,eliminatingtheneedforcomplexinstructionsorlanguagesettings.
• Automaticstartcontrolmodule
• Integratedmetering&controls
• Monitoring,protection,operationalstatus,fault conditionsandmeteringdisplayedviaLCD&LED’s
• Configurationofparametersvialicencefreesoftware
• Robustelectronicspackage
• Symbolsforsimple,intuitivecontrol
Features• Configurationofparametersbyfrontpanelpush buttonsorbyPCviaminiUSBinterface(DCP-10)or communicationsoftware(DCP-20)• TrueRMSVoltageSensing• Engine&ACmonitoring• Run/AutokeyswithLEDindicators• Under/Overvoltageprotection• Larger128×64graphicLCD(DCP-20only)• RS485,RS232orUSBportforremotecommunication (DCP-20only)• Powermetering(DCP-20only)
Benefits
FG Wilson DCPDigital Control Panels
FG Wilson DCP-10 is standard on 5.5 – 220 kVA range
PowerWizardPowerWizard – Providing safe control of your generator setTheFGWilsonPowerWizardrangeofdigitalcontrolpanels,combinestraightforwardmenunavigationwith advanced metering and protection technology. They are used in automatic mains failureapplicationsinconjunctionwithtransferpanels.
OurPowerWizardrangeallowsyoutomonitorandcontrolyourgeneratorsetwithease,whilstensuringyourunitoperateswithinsafeparametersandprovidesimportantdiagnosticinformationwhenneeded.
Digital Control Panels
PowerWizard 1.1, 1.1+ and 2.1
• Robustelectronicspackageforindustryleadingreliability• Singlemenulayoutforeaseofnavigationandmonitoringwithshortcutkeysforimmediateaccesstoengine or AC metering
• 10.5-32VDCprovidingasinglemoduletocoverthe wholeFGWilsongeneratorsetrange• Comprehensiverangeofstandardfeaturesandoptions toensurethemostappropriateconfigurationforyour needs• ServicedusingstandardEST
Features• TrueRMSVoltageSensing• CAN1DataLinkforcommunicationtoelectronic engines,CAN2(2.1only)AccessoryDataLinkfor additional modules• 40uniqueeventslogconfigurationincludingfirst,last andnumberofoccurancesandrealtimeclock• EngineandACMonitoring• Twodisplaylanguages(CustomerLanguage& TechnicianLanguage)• Upto5sparefaultchannels• Configurablesenderinput• Dedicatedkeytoresetallfaultsandmainmenushort cutkey• Run/Auto/StopkeyswithLEDindicators• Integratedmeteringandcontrolsreducingcomponents andwiring,aidingreliabilityandeaseofservice• Generatorsetvoltageandover/underfrequency protection(1.1+and2.1only)• MODBUSconnectiontobuildingmanagementsystem viaRS485(2.1only)• Powermetering(2.1only)
Benefits
PowerWizard 1.1+ is standard on 275 – 2500 kVA range
PowerWizardRemote Monitoring Options
Remote MonitoringThePowerWizardAnnunciatorisa16-channneldisplayunitforremotelymonitoringthestatusofFGWilsongeneratorsetsatadistanceofupto240metres.TheAnnunciatorcommunicatesviatheCAN2datalinkwhichcomesasstandardongeneratorsetsfittedwiththePowerWizard 2.1 Control Panel. Eachofthe16channelsontheAnnunciatorhastwoLEDstodisplaystatusandalarmsignalsdirectlyfromthePowerWizard2.1ControlPanelonthegeneratorset.Thepre-setchannelslinkedtoeachLEDdisplaycanbeindividuallyconfiguredusingtheElectronicServiceTool(EST).ThisallowsOperatorstomonitordifferentgeneratorsetstatusandalarmsignalstosuitsite-specificrequirements.InadditiontotheLEDdisplay,theAnnunciatorincludesanaudiblealarm,analarmacknowledgepushbuttonandalamptestpushbutton.
PW Panel Option Codes Annunciator Dimensions
A mm (in) B mm (in) C mm (in)
PW 2.1 ANN16 158(6.22) 130(5.12) 288(11.34)
AB
C
AB
C
The FG Wilson Communications Interface Module andSoftwarePackageallowsoperatorstomonitorandcontrolallgeneratorsetfunctionsfromavirtualcontrolpanelontheirPC.
Dependingontheoperator’sdistancefromthegeneratorset and the type of connection available to link to thegenerator set, two options are offered:
• Fordistancesupto1,000metres,whereitisconvenienttohaveahard-wiredconnection,ageneratorsetcanbe monitored using the Communications InterfaceModuleandSoftwarePackageontheoperator’sPCor laptop.
• Alternatively, when laying a hard-wired connectionis not convenient, the samemonitoring and controlfunctionalityisavailable,butcommunicationbetweentheoperator’sPCorlaptopandtheControlPanelismadethroughamodemandthetelephonenetwork.Dependingontheoperator’sdistancefromthegeneratorsetandthetypeofconnectionavailabletolinktothe generator set, two options are offered:
Remote Monitoring and Control
Additional remote monitoring and control options,via the internet, GSM and GPRS are available withPowerWizard2.1ControlPanels.Pleasecontactyourlocal FGWilsonDealerforfurtherinformation.
Operator laptopor PC
Using Telephone Network
TelephoneNetwork
Modem
Using Hard-wired Connection
Generator set withPowerWizard 2.1
Control Panel
CommunicationsInterfaceModule
CommunicationsInterfaceModule
Generator set withPowerWizard 2.1
Control Panel
Connection Via Panel Option Codes
PW2.1
Hand-wiredConnection(Upto1,000m) REM1
TelephoneNetwork REM2*
*Modemtolinktheoperator’sPCorlaptopwiththetelephonenetworkisnotincluded.Note:PCorlaptopisnotincludedinanyoftheaboveoptions.
PowerWizardRemote Monitoring and Control Options
easYgen–2500Synchronising Control Panel
easYgen–2500
• Capableofset-to-setsynchronisingforupto16generator sets
• Userfriendlyinterface• Easysystemnavigationviaprogrammablesoftkeys• MultiplecommunicationprotocolsforcommunicationwithEngineControlUnits(ECUs),externalI/Oboards,PLCs and modems
• Multilingualcapability:English,Chinese,French,German,Italian,Japanese,Polish,Portuguese,Russian,SpanishandTurkish
• Capableofworkingwithallcommonindustrialinterfaces
Features
• Powerandreactivepowerloadsharingupto16unitsincludingload-dependentstart/stop
• Enginestart/stopandgeneratorsetmeasuringandprotection
• Runninghoursbalancing• Breakercontrol:synchronization,open-closecontrol, only-opencontrol,breakermonitoring• Deadbusclosurenegotiation• PLC-likeprogrammingwithLogicsManager• 300-entry,timeanddatestamplog• Operatinghours/start/maintenancecounters• Configurabletriplevels/delays/alarmclasses• Fieldconfigurableapplicationsettings• Multi-levelpasswordprotection
Benefits
The easYgen-2500 offers industry leading power management and control
TheeasYgen-2500isageneratorset-to-setcontrollerforparallelingandloadsharingapplicationsofupto16generatorsets.AspecialfeatureoftheeasYgen-2500istheenhancedloadsharingsystem.Thisprovidesadvancedgeneratorloaddependentstart/stopfunctionalitywithautomaticgeneratorsetselectiontoensureoptimalsystemefficiency.
Generator Set• Over/undervoltage• Over/underfrequency• Deadbusdetection• Overload• Reverse/reducedpower• Timeovercurrent• Instantaneousovercurrent• Inversetimeovercurrent• Phaserotation• Unbalancedload• Powerfactor
Engine• Over/underspeed• Batteryover/undervoltage• Speed/frequencymismatch
Inputs / Outputs (I/O)
• 3phasetruer.m.s.generatorsetcurrent/power• 1speedinput(magnetic/switching)• 10configurablediscretealarminputs• Fiveconfigurableanalogueinputs• Fourconfigurableanalogueoutputs (+/–10V,+/–20mA,PWM;configurable)
• TwoCANbusinterface(loadshare,Toolkit)• 11RelayOutputsIsolated• RS485Modbusinterface• ServicePort (RS232–WoodwardDPCcablerequired)
ProtectionService / Configuration
Loadshare Line57/58
CAN 1
CAN BusEngine Level
MPU
Measuring
FrequencyBiasing
VoltageBiasing
10 Digital Inputs
11 Digital Outputs
5 Analogue Inputs
ECU
2 x I / OExpansion
board
USB toCAN
DPCCable
SCADA
87/90
CAN 22 Analogue Outputs
Service Port RJ45
55/56
USB
• J 1939
• 16 Digital Inputs• 16 Digital Outputs
easYgen–2500
easYgen–3200†
Synchronising Control Panel
easYgen–3200
• Capableofgeneratorset-to-set,set-to-mainsandmultiple set-to-mainssynchronisationforupto32generatorsets• Enhancedsystemflexibilitymeetsdemandingcustomer specifications• Userfriendlyinterfacevia320x240pixelgraphical interactive5.7”LCD• Easysystemnavigationviaprogrammablesoftkeys• Multilingualcapability:English,Chinese,French, German,Italian,Japanese,Polish,Portuguese, Russian,Spanish,TurkishandFinnish• Multiplecommunicationprotocolsforcommunication withEngineControlUnits(ECUs),externalI/Oboards, PLCs and modems
Features
• Powerandreactivepowerloadsharingupto32unitsincludingload-dependentstart/stop
• Enginestart/stopandgeneratorsetmeasuringandprotection
• Automaticbaseloading• Runninghoursbalancing• Import/exportcontrol• Deadbusclosurenegotiation• ECUmonitoringandalarmmanagementaswellas remotestart/stopandcontrolcommands• PLC-likeprogrammingwithLogicsManager• 300-entry,timeanddatestamplog• Operatinghours/start/maintenancecounters• Configurabletriplevels/delays/alarmclasses• Fieldconfigurableapplicationsettings• Multi-levelpasswordprotection• RP3000remotedisplaypanelavailablefor managementandcontrolfromadjacentplantroom
Benefits
The easYgen-3200 offers industry leading power management and control
The easYgen-3200 is a versatile control unit, incorporating all the features of the easYgen-2500includingenhancedloadsharing,andisadaptabletoeveryapplication.Typicalapplicationsinclude co-generation, standby,AMF,peak shaving, import / exportordistributedgeneration. This controlpanelissuitableforsynchronisingupto32generatorsetsrunninginislandmode,mainsparallelandmultiple unit mains parallel operations.
† Available through Power Solutions
Generator Set• Over/undervoltageandfrequency• Deadbusdetection• Overload• Unbalancedload• Reverse/reducedpower• Timeovercurrent• Instantaneousovercurrent• Measured ground fault• Phaserotation• Powerfactor
Engine• Over/underspeed• Batteryover/undervoltage• Auxiliaryexcitation• Speed/frequencymismatch
Mains• Over/undervoltageandfrequency• Phaseshift• Rotation field
Inputs / Outputs (I/O)
• Twoseparatesetsof3-phasetruer.m.s.voltage measuringinputsforthegeneratorsetand mains,and2-phasebusbarvoltage• 3-phasetruer.m.s.generatorsetcurrent/power• 1-phasetruer.m.s.currentinputfreelyconfigurable• 1speedinput(magnetic/switching)• 10configurablediscretealarminputs
Protection Service / Configuration
Guidance / LoadShare Level
RS232
CAN 1
RS485 1
CAN Bus Engine Level
CA
N 2
MPU
FrequencyBiasing
VoltageBiasing
10 Digital Inputs
12 Digital Outputs
3 Analogue Inputs
AC Measurement:• 4 x U Gen, 3 x l Gen• 2 x U Bus• 4 x U Mains, 1 x l Mains
MCB GCB
• J 1939 including 100 SPN text events
• 16 Digital Inputs• 16 Digital Outputs
ECU
2 x I/OExpansion
board
PLC /SCADA
• Upto12programmablediscreteoutputs• Threeconfigurableanalogueinputs• Twoconfigurableanalogueoutputs• TwoCANbuscommunicationnetworks(upto 32participants,isolated)• TwoserialportssupportingModbusRTU Protocol,RS-485andRS-232(isolated)
easYgen–3200
easYgen Control Panel OptionsNetBiter® FGW200Remote management for new and existing generator set installations
With softwaredesignedexclusively forFGWilson, theFGW200offersnewopportunities for remote accessovertheinternetandmobilephone.TheNetBiterunitissuitableforuseinnewandexistinginstallationsduetocontrolpanelAutoDetectsoftwarewhichoffersplugandplaycapability.
Remote management that takes customer service to a new level by:
Features
• NewAutoDetectsoftwareallowsretrofittoPowerWizard2.1,easYgen-2500, easYgen-3200controlpanelsandATItransferpanels
• Builtinwebinterfacefordatamonitoring• BuiltinalarmmanagerforSMS,emailandSNMP• Builtindataloggerofhistoricaltrends• GSM/GPRSmodemincluded• Allsoftwareincluded,easilyupgradedremotelyandprovidedwithnolicensingcost
• Reducingtheneedtotraveltoremotesitesfor maintenancepurposes• Minimisingdowntimewithinstantinformationabout equipmenthealth• Theftpreventionthroughgeneratorsettracking• Fuellevelmonitoringtooptimisefuelinventory• Startuploggingtohelppreventgeneratorsetmisuse• AllowingmultipleprojectanddevicemanagementthroughNetBiter.net
I/O Expansion Module†
Connection to and from external system devices enabling more flexibility to meet your specfic power requirements.
Features
easYgen Control Panel Options
• 8configurablediscretealarminputs• 8configurablerelayoutputs• ConnectiontoeasYgencontrolpanelviaCANbus• InputandoutputconfigurationviaonboardeasYgenrelaymanager
• RemotecontrolofoutputrelaysviaCANbus• TheI/OExpansionModulecanbeusedwithothermanufacturer’scontrols.ConsultWoodwardproductmanual37135forinformationregardingtheaddressassignmentsoftheCANbusinterface
† Available through Power Solutions
Load Transfer Panels24 Hour Power Protection 365 days a year...
Load Transfer Panel Range
• Fullyautomaticmainsfailuresensingandgeneratorsetstart signal
• Pre-programmedenablingthepaneltorunoninstallationwiththeabilitytocustomiseifnecessary
• Fastactingswitchesreducetransfertimesbetweensetandutilitypower
• Availablefrom63–3200A• SeamlessintegrationwithFGWilsondigitalcontrol
panels
Benefits
FG Wilson’s range of intelligent Load Transfer Panels offer you peace of mind.
TheFGWilsonLoadTransferPanelrangeoffersanelectronicallycontrolledresponsetopoweroutages. Withflexible,upgradeableoptionsandahighleveloffunctionalityFGWilsontransferpanelsprovide24-hourautomaticcontrolofstandbygeneratorsets,365daysayear.
• Automaticandmanualoperation• Automaticallyprovidesgeneratorsetstartsignalupon detectionofmainsfailure,overvoltageorlossofphase• Automaticmainsre-transferfunction• Flexible,upgradeableoptions• Testoperationsandsequencesaccessiblefrompanelorremotely
• Manualswitchoperationpossibleviaexternalhandle• LEDfunctionsdisplayshowinggeneratorset/mains availabilityandswitchposition• LCDdisplayforvoltageandtimers• LoadtransferpanelrangemeetsATSIEC60947-6-1 standard
Features
Model Rating ATI Transfer Dimensions Weight
A mm (in) B mm (in) C mm (in) kg (Ib)
ATI250 250A 900(35.4) 600(23.6) 323(12.7) 39(86.0)
ATI400 400A 900(35.4) 600(23.6) 323(12.7) 44(97.0)
ATI630* 630A 1100(43.3)† 600(23.6) 398(15.7) 66(145.5)
ATI800* 800A 1375(54.1) 775(30.5) 600(23.6) 125(275.6)
ATI1000* 1000A 1375(54.1) 775(30.5) 600(23.6) 130(286.6)
ATI1250* 1250A 1800(70.8) 1005(39.6) 775(30.5) 230(507.1)
ATI1600* 1600A 1800(70.8) 1005(39.6) 775(30.5) 330(727.7)
ATI2000* 2000A 2200(86.6) 1000(39.4) 1000(39.4) 400(881.8)
ATI2500* 2500A 2200(86.6) 1000(39.4) 1000(39.4) 400(881.8)
ATI3200* 3200A 2200(86.6) 1000(39.4) 1000(39.4) 400(881.8)
Model Rating ATI Transfer Dimensions Weight
A mm (in) B mm (in) C mm (in) kg (Ib)
CTI63 63A 600(23.6) 400(15.7) 200(7.9) 19(41.8)
CTI100 100A 600(23.6) 400(15.7) 200(7.9) 19(41.8)
CTI125 125A 600(23.6) 400(15.7) 200(7.9) 19(41.8)
CTI160 160A 600(23.6) 400(15.7) 200(7.9) 19(41.8)
*Floorstanding.†DimensionAforthetopcableentrymodelwillchangeto1350mm(53.1in)
ATI wall mountedCTI wall mounted Floor standing (ATI only)
Load Transfer Panels
CTI Panel Features
CTI Load Transfer Panel – Ratings 63 – 160 AmpsKey: – Standard Feature – Optional Feature
Programmable Countdown Timers
Setroutinetimesfordelayonstarts,delayontransfer,delay
on re-transfer and run on timer.
Manual HandleFullyintegratedhandleformanual operation.
PadlockableSwitchcanbepadlockedinallthreepositionsforaddedsecurityandsafety.Onlypossibleinmanualoperationmode.
Wall Mounting KitPanelcanbewallmounted
forgreaterflexibilityinpositioning.
Auto/Manual/Test Mode Status IndicationAllowson/offloadtestsatroutineservicechecks.
LCD DisplayShowsdetailedstatusofsystematalltimesfor
greater awareness and control.
Control TerminalsGenerator set remote start signal and terminals for remotelymonitoringthesystem.
System Status Indicators
Showsstatusofutilitypower,generatorsetandswitchat
all times.
Voltage Sensing Tap
Allows for pole voltagesensing.
KeypadForstraightforwardprogramming and testing. Passwordprotectionisincluded.
Terminal shroudForaddedprotection.
Auxiliary ContactsAuxiliary/voltfreecontactsforremotelymonitoringtheswitchposition.
Solid Neutral KitAllowstheconnectionofneutralcablesfromutilitypower, generator set and loadwithouthavingthe
neutralbrokenbytheswitchduring transfer operations.
Auxiliary ControlsAuxiliaryinputsforautomaticcontrol,remotetestonloadandmanual re-transfer.
Top and Bottom Cable Entry Aids ease of installation
Lightning Protection Ensuringsystemsafety
Load Terminal Extensions Improvingeaseofinstallation
Ingress Protection IP54 Protectionforthecontrolpanel
Load Transfer Panels
ATI series
ATI Load Transfer Panel – Ratings 250 – 1600 Amps
RS485 Communications ModuleEnablesaccesstothesystemremotelythrough
telephoneorPCviamodem.
LCD DisplayShowsdetailedstatusofsystematalltimesforgreater awareness and control.
Programmable Countdown TimersSetroutinetimesfordelayonstarts,delayontransfer,delayonre-transferandrunon timer.
Wall Mounting KitPanelcanbewallmounted
forgreaterflexibilityinpositioning(ATI250and
400).
Power MeteringTomeasureloadcurrent,kW,kVAr,kVA,powerfactor.
Manual HandleFullyintegratedhandlefor
manual operation.
PadlockableSwitchcanbepadlockedinallthreepositionsforadded
securityandsafety.
Solid NeutralAllowstheconnectionofneutralcablesfromutilitypower, generator set and loadwithouthavingthe
neutralbrokenbytheswitchduring transfer operations.
Auto/Manual/Test Mode Status IndicationAllowson/offloadtestsatroutineservicechecks.
Auxiliary ContactsAuxiliary/voltfreecontactsforremotelymonitoringsystem;switchposition,padlockandautomaticormanualoperation.
Volt Free ContactsForpoweravailableandgeneratoravailable.
Lightning ProtectionEnsuresthesafetyofsystemduringlightningstorms(includesvoltfreecontactsforutilitypowerandgeneratorset).
System Status Indication
Showsstatusofutilitypower,generatorsetandswitchat
all times.
KeypadForstraightforwardprogramming and testing. Passwordprotectionisincluded.
Two Wire Start Signal
Simpletwowireconnectionforautomaticcontrol.
Bottom Gland PlateRemovableglandplateproviding
increasedaccessibilitywithasizeableareaforutilitypowerandgeneratorsetcablestobe
connected.
Installation Typicalinstallationsetup
Ingress Protection IP54Protectionforthecontrolpanel
Wall Mounting PanelsWallmountwithease–includesfittings
Top Cable Entry Aids eased installation
Key: – Standard Feature – Optional Feature
ATI Panel Features
ATI series
ATI Load Transfer Panel – Ratings 2000 – 3200 Amps
RS485 Communications ModuleEnablesaccesstothesystemremotelythrough
telephoneorPCviamodem.
LCD DisplayShowsdetailedstatusofsystematalltimesforgreater awareness and control.
Programmable Countdown TimersSetroutinetimesfordelayonstarts,delayontransfer,delayonre-transferandrunon timer.
Manual HandleFullyintegratedhandlefor
manual operation.
PadlockableSwitchcanbepadlockedinallthreepositionsforadded
securityandsafety.
Auto/Manual/Test Mode Status IndicationAllowson/offloadtestsatroutineservicechecks.
Auxiliary ContactsAuxiliary/voltfreecontactsforremotelymonitoringsystem;switchposition,padlockandautomaticormanualoperation.
Volt Free ContactsForpoweravailableandgeneratoravailable.
Lightning ProtectionEnsuresthesafetyofsystemduringlightningstorms(includesvoltfreecontactsforutilitypowerandgeneratorset).
System Status Indication
Showsstatusofutilitypower,generatorsetandswitchat
all times.
KeypadForstraightforwardprogramming and testing. Passwordprotectionisincluded.
Two Wire Start Signal
Simpletwowireconnectionforautomaticcontrol.
Bottom Gland PlateRemovableglandplateproviding
increasedaccessibilitywithasizeableareaforutilitypowerandgeneratorsetcablestobe
connected.
Installation Typicalinstallationsetup
Ingress Protection IP54Protectionforthecontrolpanel
Key: – Standard Feature – Optional Feature
ATI Panel Features
Features and Options1002T DCP-10 DCP-20 PW 1.1 PW 1.1+ PW 2.1 easYgen
2500easYgen3200+
Instrumentation
LCDDisplaywithAutoPowerff – – –
BatteryTrickleChargeAmmeter – – –
AudibleAlarm –
RemoteAnnunciator – – – – –
AC
Met
erin
g
Voltmeter3-phase(L-L&L-N)
Amps(perphaseandaverage)
Frequency
kW(total&perphase) – – – –
kVA(total&perphase) – – – –
kVAr(total&perphase) – – – –
PowerFactor(overallandperphase) – – – –
kWHours – – – –
kVArHours – – – –
DC
Met
erin
g
BatteryVoltmeter –
EngineHoursRun
EngineJacketWaterTemperature(in°Cor°F) –
LubeOilPressure(inPsi,kPAorbar) –
EngineSpeed(rpm) – –
CrankAttemptCounter – – – –
StartCounter – – – –
Protection
FailtoStart –
Low Oil Pressure
HighEngineTemperature
Underspeed,Overspeed –
LossofEngineSpeedDetection – – –
Low/HighBatteryVoltage –
BatteryChargerFailure(ifBatteryChargerfitted) – – –
UnderVolts,OverVolts – –
UnderFrequency,OverFrequency – – – –
Overcurrent – – – – –
ConfigurableSenderInput (for'OilTemperature'or'FuelLevel'optionsonly) – – – –
EarthLeakageProtection – – –
EarthFault Protection – – –
Low Fuel LevelAlarm –
Low Fuel LevelShutdown – – –
HighFuel LevelAlarm – – –
FuelTransferSystemControl – –
Low CoolantLevelShutdown – – –
Low Coolant Temperature Alarm –
HighLubeOilTemperatureShutdown – – –
OverloadviaAlarmSwitchonBreaker – – – –
OverloadviaOverCurrentRelay – – – – –
Low Gas Pressure – – – – – – –
HighGasPressure – – – – – – –
HighExhaustTemperatureAlarm – – –
1002T DCP-10 DCP-20 PW 1.1 PW 1.1+ PW 2.1 easYgen 2500
easYgen3200+
Protection Monitoring
NameofEachEvent – – –
EngineHoursatFirstOccurrenceofEvent – – –
TimeandDateofFirstOccurrenceofEvent – – – – –
EngineHoursatLastOccurrenceofEvent – – –
NumberofOccurrencesofEvent – – –
Instrumentation
SpareFaultChannels
NumberofChannelsAvailable 0 0 4 3 5 5 5 6
Exceptions:
OnmodelsP730P1–P1100E1 – – – – 3 3 4 5
OnmodelsP1250–P2500-1 – – – – 2 2 3 4
Controls
2LEDStatusIndicators(1redshutdown,1amberwarning) – –
Runkey,AutoKeyandStopKeywithLEDindicators –
Lamp Test
AlarmAcknowledgeKey –
MenuNavigationKeys –
DedicatedKeytoresetallevents – – – – –
EngineandACMeteringShortCutKeys – – – – –
MainMenuandEventLogShortCutKeys – – –
ControlModuleKeyswithTactileFeedback – – –
CAN1DataLink-J1939forcommunicatingwith electronicenginecontrolmodules – – –
CAN2AccessoryDataLink-foradditionalmodulesremoteannuncia-tor,digitalinput/outputmodule – – – – –
RemoteMonitoringandControlDataLink(ModBus) – – – – –
RealTimeClock – – – – –
ServiceMaintenanceIntervalWarning – – – – –
Remote Monitoring and Control – – – – –
StaticBatteryCharger – – –
StaticBatteryChargerwithAutoBoost –
VoltFreecontactsfor:CommonAlarm&GeneratorSetRunning –
EngineCoolantHeaterControls – – –
Control Panel Heater – – – – –
VoltsAdjustPotentiometer – – –
SpeedAdjustPotentiometer – – –
SpeedAdjustSwitch – – –
OilTemperatureDisplay – – – –
Oil Temperature Gauge – – – – –
LubeOilTemeperaturedisplayedonLCDscreen – – –
FuelLevelSwitch – – – –
FuelLevelSender&Display – – –
PanelLockdownStopPushButtonwithsecuritykey – – – – –
NetbiterInternetMonitoringandControlUnit – – – – – –
MainsLoadSensingUnit – – – – – – –
Additional8inputsand8outputs – – – – – – –
Key: –Standard;–Optional
Panel Display languagesArabic*,Bulgarian*,Chinese,Czech*,Danish*,Dutch*,English,Estonian*,Finnish*,French,German,Greek*,Hungarian*,Icelandic*,Italian,Janpanese,Latvian*, Lithuanian*,Norwegian*,Polish,Portuguese,Romanian*,Russian,Slovak*,Slovene*,Spanish,Swedish*,Turkish.
*NotavailableforeasYgencontrolpanels.+AvailablethroughPowerSolutions.
Features and Options
CTI ATI < 1600A ATI > 2000AMotorised Mechanically Held Switch
Facilityformanualchangeover
Protection
Utlitypoweravailable
Utilitypoweronload
Generatoravailable/Generatoronload
Utilitypowerandgeneratoroffload
Manualmode/Automaticmode
Testonload/Testoffload
Manualre-transferforenabled/required
Power/Errorindication(LED)
Facia
Universalsymbolstoallowformultiplelanguages
Liquid Crystal Display
UtilityPowerL1-2,L1-3,L2-3voltage
UtilityPowerL1-N,L2-N,L3-Nvoltage
GeneratorSetL1-N,L2-N,L3-Nvoltage
GeneratorSetL1-2,L1-3,L2-3voltage
UtilityPowerFrequency/GeneratorSetFrequency
Numberoftimesswitchtransfersfrommainstogeneratorset
Timer settings
Standards
CompleteenclosuremeetsstandardIEC60947-6-1
SwithmeetsstandardAC31B
Controls
Under/Overfrequencyfailure
Under/Overfrequencyrestoration
Manual/Autore-transfer
Modeselectpushbutton
Under/OverVoltsFailure
Under/OverVoltsRestoration
DelayonStartTimer
DelayonTransfer
DelayonRe-Transfer
DeadBandTimer
Run On Timer
Auto/ManualControlKeyswitch
LampTestPushbutton
Padlockfacility
SelectionbetweenContactororSwitchMode – –
Cable entry
Top –
Bottom
Load Terminal Extensions
Improvingeaseofinstallation – –
Features and Options
CTI ATI < 1600A ATI > 2000AAuxiliary Contacts
Formonitoringofswitchposition(Includingpadlocking&auto/manual) –
Lightning Protection
Ensuringthesafetyofsystemduringlightningstorms
Ingress Protection IP54
Protectionforcontrolmodule
Power Metering
Tomeasureloadcurrent,kW,kVAr,kVA,Powerfactor –
Volt Free Cotacts
Forutilitypoweravailability&generatoravailable
Communication Module
PluginmodulethatusesJbus/modbusprotocoltoallowremotecommunicationofthechangeoversystem –
Voltage Sensing Tap
Allowingforpolevoltagesensing – –
Solid Neutral Kit
Toconnectneutralcablesfromthemains,generatorsetandload –
Terminal Shroud
Foraddedprotection – –
Key: –Standard;–Optional
Note:Optionsavailabledependsontheexactconfigurationofthegeneratorsetpackage.Notalloptionsareavailableonallpackages.PleasecontactyourlocalFGWilsonDealerformoreinformation
FG Wilson manufactures product in the following locations:Northern Ireland • Brazil • China • India • USAWith headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network.To contact your local Sales Office please visit the FG Wilson website at www.FGWilson.com.
FG Wilson is a trading name of Caterpillar (NI) Limited.In line with our policy of continuous product development, we reserve the right to change specification without notice. ControlPanelRange/0513/GB