FERRITE CONTENT MEASUREMENT 1) Why ferrite measurement is required ? 2) What is acceptable limit for SS O/L weld? 3) Which instrument is used for Ferrite check 4) What is measurement application capabilities? 5) What is memory capacity OR application ? 6) Which power supply is used ? 7) Which factors affect

Ferrite Content Measurement

Embed Size (px)

DESCRIPTION

Ferrite Content Measurement

Citation preview

Page 1: Ferrite Content Measurement

FERRITE CONTENT MEASUREMENT

1) Why ferrite measurement is required ?

2) What is acceptable limit for SS O/L weld?

3) Which instrument is used for Ferrite check

4) What is measurement application capabilities?

5) What is memory capacity OR application ?

6) Which power supply is used ?

7) Which factors affect the ferrite content measurement with

feritscope m30 ?

Page 2: Ferrite Content Measurement

Technical Data and Contents

Instrument types : FERITSCOPE MP30

Display : LC display with symbols and

prompts to guide the users

Measurement : ferrite content measurement in

application weld metal and clade layers of

austenitic or Duplex SS

Dimensions : Instrument :160 L x 80 W x 30 T

Display : 60 L X 30 W

Weight ; 250 g

Temperature range: 5 …. 45 ‘ C

During operation

Application : 100 for up to 10,000 measurement.

Accuracy : Depending on the connected probe.

Power supply : 9V battery for up to 25 hrs of operation

or

9V rechargeable NiCd battery for up to 5

hrs operation (battery can be recharge)

Power consumption : 0.2 W

Page 3: Ferrite Content Measurement

Environmental Condition ,handling the probes and handling the base and the

calibration standards

• Instrument and accessories are designed for use at temperature between 5 and 45 ‘ c (41 … 113’f) .the equipment may be stored at temperature between 5 and 60 ‘C.

• Make sure to avoid direct contact of acid or acid solution with the instrument or the accessories.

• Place the probes rapidly, but gently on the surface of the measuring

• Do not drag the probe over the surface of the measuring object

• do not dirt or scratch the calibration standards! Corroded, dirtied or scratched calibration standards or standards with deep gouges have to be replaced by new standards

• To protect the calibration standards from dirt or damage ,keep and store the standards in the supplied calibration case.

Page 4: Ferrite Content Measurement

Conversion curve of FN to Fe%

100

80

60 %

40

20 20 40 60 80 100 120

fn

Page 5: Ferrite Content Measurement

Correction Factors

• The following factorrs affect the ferrite content measurement with the FERITSCOPE MP 30

curvature of the measuring object

Thickness for the measuring object

Layer thickness

Distance of the measuring position to the edge