2
mesaproducts.com FENCE TO FENCE: The Complete Terminal Package MESA’s expanding services division encompasses engineering, cathodic protection and integrity services for tanks, terminals, and pipelines. From assessment to maintenance, including analysis, installation and corrective action, MESA provides the expertise, qualifications, and capabilities to satisfy virtually all corrosion control requirements. Fence to Fence, MESA is the complete integrity solutions provider for terminal operators. MESA’s approach for pipeline integrity is based on an EDCA process. Through the four-step process, MESA engineers and technicians provide comprehensive evaluations and develop remediation schemes designed specifically for terminal piping facilities. Beginning with the initial evaluation of the existing cathodic protection program, MESA gathers information from single bottom and double bottom tanks, as well as tanks equipped with environmental liner. Our tank evaluation plan ensures that every tank is assessed and corrective action is developed to either meet industry standards or your specific policy and accepted criteria. MESA’s installation crews provide a unique combination of technologies, equipment, skills, and experience, which enables us to evaluate and implement appropriate corrective actions. MESA designs and installs corrosion rate probes and/or vapor-phase corrosion inhibitors to control corrosion within the inaccessible interstitial space on double bottom tanks, or those equipped with environmental liners. MESA’s horizontal directional drilling equipment provides the capability to design and install under-tank reference electrodes and replaceable cathodic systems for new and existing ASTs. The knowledge and experience of MESA’s team ensures that your project will be completed timely and correctly, with follow-up measures identified to ensure the continued success of your corrosion control and integrity program. MESA’s comprehensive CP and integrity expertise enables us to complete any job safely and with complete confidence. Call us today for an assessment of an existing terminal, pipeline, or other application. Above-ground Storage Tanks Piping Manifolds Loading Racks Transmission Pipelines Terminal Piping Delivery Lines Refineries Headquarters 4445 S. 74th E. Ave Tulsa, OK 74145 918.627.3188 [email protected]  Southeast- Services P.O. Box 14325 Tallahassee, FL 32317 850.893.9366  Southeast- Materials 843.271.8069  Gulf Coast 16740 Hedgecroft Suite 412 Houston, TX 77060 281.445.8700  West Coast 17461 Apex Circle Huntington Beach, CA 92647 714.963.6202  Dallas/Ft. Worth 12441 Bus. Hwy. 287N Ft. Worth, TX 76179 817.230.4249  Midwest 1208 Lunar Drive Wapakoneta, OH 45895 419.738.7402

FENCE TO FENCE - MESA Cathodic Protection & … · Beginning with the initial evaluation of the existing cathodic protection program, MESA gathers information from ... Refineries

Embed Size (px)

Citation preview

mesaproducts.com

FENCE TO FENCE: The Complete Terminal Package

MESA’s expanding services division encompasses engineering, cathodic protection and integrity services for tanks,

terminals, and pipelines. From assessment to maintenance, including analysis, installation and corrective action,

MESA provides the expertise, qualifications, and capabilities to satisfy virtually all corrosion control requirements.

Fence to Fence, MESA is the complete integrity solutions provider for terminal operators.

MESA’s approach for pipeline integrity is based on an EDCA process. Through the four-step process, MESA engineers

and technicians provide comprehensive evaluations and develop remediation schemes designed specifically for

terminal piping facilities.

Beginning with the initial evaluation of the existing cathodic protection program, MESA gathers information from

single bottom and double bottom tanks, as well as tanks equipped with environmental liner. Our tank evaluation

plan ensures that every tank is assessed and corrective action is developed to either meet industry standards or your

specific policy and accepted criteria.

MESA’s installation crews provide a unique combination of technologies, equipment, skills, and experience, which enables

us to evaluate and implement appropriate corrective actions. MESA designs and installs corrosion rate probes and/or

vapor-phase corrosion inhibitors to control corrosion within the inaccessible interstitial space on double bottom tanks,

or those equipped with environmental liners. MESA’s horizontal directional drilling equipment provides the capability to

design and install under-tank reference electrodes and replaceable cathodic systems for new and existing ASTs.

The knowledge and experience of MESA’s team ensures that your project will be completed timely and correctly,

with follow-up measures identified to ensure the continued success of your corrosion control and integrity program.

MESA’s comprehensive CP and integrity expertise enables us to complete any job safely and with complete confidence.

Call us today for an assessment of an existing terminal, pipeline, or other application.

Above-ground Storage Tanks

Piping Manifolds Loading Racks

Transmission Pipelines

Terminal PipingDelivery Lines

Refineries

Headquarters4445 S. 74th E. AveTulsa, OK [email protected] Southeast- ServicesP.O. Box 14325 Tallahassee, FL 32317850.893.9366 Southeast- Materials843.271.8069 Gulf Coast16740 Hedgecroft Suite 412Houston, TX 77060281.445.8700 West Coast17461 Apex CircleHuntington Beach, CA 92647714.963.6202 Dallas/Ft. Worth12441 Bus. Hwy. 287NFt. Worth, TX 76179817.230.4249 Midwest1208 Lunar DriveWapakoneta, OH 45895419.738.7402

Directional Drill Rig

Underground and Above-ground Piping

Above-ground Storage Tanks (ASTs)

• Step 1: Pre-Assessment (Data Gathering)

• Determine Feasibility of ECDA

• Selection of Regions

• Define Assessment Tools

• Step 2: Indirect Inspection

• Pipeline Centerline, GPS, Flag

• Close Interval Survey

• Direct Current Voltage Gradient

• Soil to Air Interface Evaluations

• Electrical Isolation Piping Support

• Step 3: Direct Examination

• Corrosion Mapping

• Coating Condition

• Ultrasonic Thickness Measurements

• Visual Documentation

• Magnetic Particle Testing

• Step 4: Post Assessment

• Remaining Life Calculations

• Re-assessment Interval

• Program Validation

• ECDA Effectiveness

• Root Cause Analysis

• Continuous Improvement Evaluation

• Evaluate Existing Cathodic Protection Program

• Gather CP information

• Type of Tank Bottoms

• Single Bottoms

• Double Bottoms

• Single Bottom/Liner

• Evaluate Existing Tanks

• Tank Bottom Evaluation Plan

• Single Bottom Tanks and CP

- Install Reference Electrodes

• Double Bottom Tanks and CP

- Install Corrosion Rate Probes

• Corrective Action

• Set up Monitoring Program

• Vapor-phase Corrosion Inhibitor (VpCI)

- Double Bottom

- Single Bottom/Liner

• Add Cathodic Protection

• Assessment and Maintenance

• Perform monitoring

• Annual Survey and Assessment