SHENZHEN POCE TECHNOLOGY CO., LTD. REPORT NO.:POCE16071933XRF
H Building, Hongfa science and Technology Park, Tangtou, Shiyan, Bao’an District, Shenzhen, China page 1 of 18 Tel: +86-755-29113252 Fax: +86-755-29113135 http://www. poce-cert.com
FCC TEST REPORT For
Shenzhen Yihexin Technology Co., Ltd.
Product Name: LED Headlamp
Model No.: Reference page 3
Note: This test report is limited to the above client company and the product model only. It may not be duplicated without prior written consent of Shenzhen POCE Technology Co., Ltd.
Prepared for : Shenzhen Yihexin Technology Co., Ltd.
Address : 4F, 2B Building, No. 91 Lixin Road, Danzhutou Community,
Nanwan Street, Longgang District, Shenzhen, Guangdong
Province, China
Prepared by : SHENZHEN POCE TECHNOLOGY CO., LTD.
Address : H Building, Hongfa Science And Technology Park, Tangtou,
Shiyan, Bao’an District, Shenzhen, China
Date of receipt of test sample : Jul. 14, 2016
Number of tested samples : 1
Serial number : Prototype
Date of Test : Jul. 14, 2016 –Jul. 19, 2016
Date of Report : Jul. 19, 2016
SHENZHEN POCE TECHNOLOGY CO., LTD. REPORT NO.:POCE16071933XRF
H Building, Hongfa science and Technology Park, Tangtou, Shiyan, Bao’an District, Shenzhen, China page 3 of 18 Tel: +86-755-29113252 Fax: +86-755-29113135 http://www. poce-cert.com
Traceability of Device EUT..................................... : LED Headlamp Type / Model.............. : B5, B6, B7, B8, B9, B10, B11, B12, B13, B14, B15, B16, B17,
B18, B19, B20, B21, B22, B23, B24, B25, B26, B27, B28, B29, B30, B31, B32, B33, B34, B35, B36, B37, B38, B39, B40, B41, B42, B43, B44, B45, B46, B47, B48, B49, B50
Applicant........................... : Shenzhen Yihexin Technology Co., Ltd. Address............................. : 4F, 2B Building, No. 91 Lixin Road, Danzhutou Community,
Nanwan Street, Longgang District, Shenzhen, Guangdong Province, China
Telephone........................... : / Fax..................................... : / Manufacturer...................... : Shenzhen Yihexin Technology Co., Ltd. Address.............................. : 4F, 2B Building, No. 91 Lixin Road, Danzhutou Community,
Nanwan Street, Longgang District, Shenzhen, Guangdong Province, China
Telephone........................... : / Fax..................................... : / Factory................................ : Shenzhen Yihexin Technology Co., Ltd. Address.............................. : 4F, 2B Building, No. 91 Lixin Road, Danzhutou Community,
Nanwan Street, Longgang District, Shenzhen, Guangdong Province, China
Telephone........................... : / Fax..................................... : /
Test Result: PASS
The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory.
SHENZHEN POCE TECHNOLOGY CO., LTD. REPORT NO.:POCE16071933XRF
H Building, Hongfa science and Technology Park, Tangtou, Shiyan, Bao’an District, Shenzhen, China page 4 of 18 Tel: +86-755-29113252 Fax: +86-755-29113135 http://www. poce-cert.com
TABLE OF CONTENTS
Description Page The Report Description
1.GENERAL INFORMATION ........................................................................................................................ 5 1.1. Client Details ........................................................................................................................................... 5 1.2. Test Lab Details ....................................................................................................................................... 5 1.3. Description of E.U.T................................................................................................................................ 5 1.4. AE used during the test............................................................................................................................ 5 1.5. Description of test facility........................................................................................................................ 5 1.6. Test Standards .......................................................................................................................................... 6 1.7. Test Summary .......................................................................................................................................... 6 1.8. Measurement Uncertainty........................................................................................................................ 6
2.POWER LINE CONDUCTED MEASUREMENT..................................................................................... 7 2.1. Test Equipment ........................................................................................................................................ 7 2.2. Block Diagram of Test Setup................................................................................................................... 7 2.3. Power Line Conducted Emission Measurement Limits (Class B)........................................................... 7 2.4. Configuration of EUT on Measurement .................................................................................................. 8 2.5. Operating Condition of EUT ................................................................................................................... 8 2.6. Test Procedure ......................................................................................................................................... 8 2.7. Power Line Conducted Emission Measurement Results ......................................................................... 8
3.RADIATED EMISSION MEASUREMENT ............................................................................................... 9 3.1. Test Equipment ........................................................................................................................................ 9 3.2. Block Diagram of Test Setup................................................................................................................... 9 3.3. Radiated Emission Limit (Class B) ....................................................................................................... 10 3.4. EUT Configuration on Measurement..................................................................................................... 10 3.5. Operating Condition of EUT ................................................................................................................. 10 3.6. Test Procedure ....................................................................................................................................... 10 3.7. Radiated Emission Measurement Results.............................................................................................. 11
4.TEST SETUP PHOTO ................................................................................................................................. 13
SHENZHEN POCE TECHNOLOGY CO., LTD. REPORT NO.:POCE16071933XRF
H Building, Hongfa science and Technology Park, Tangtou, Shiyan, Bao’an District, Shenzhen, China page 5 of 18 Tel: +86-755-29113252 Fax: +86-755-29113135 http://www. poce-cert.com
1. GENERAL INFORMATION
1.1. Client Details Applicant: Shenzhen Yihexin Technology Co., Ltd.
Address: 4F, 2B Building, No. 91 Lixin Road, Danzhutou Community, Nanwan Street,
Longgang District, Shenzhen, Guangdong Province, China
Manufacturer: Shenzhen Yihexin Technology Co., Ltd.
Address: 4F, 2B Building, No. 91 Lixin Road, Danzhutou Community, Nanwan Street,
Longgang District, Shenzhen, Guangdong Province, China
1.2. Test Lab Details Name : Shenzhen POCE Technology Co., Ltd.
Address: H Building, Hongfa science and Technology Park, Tangtou, Shiyan, Bao’an
District, Shenzhen, China
Telephone: 86-755-29113252
Fax: 86-755-29113135
Site Listed with Federal Communication Commission
Registration Number: 222278
For 3m chamber
1.3. Description of E.U.T. Product: Shenzhen Yihexin Technology Co., Ltd.
Model No.: B22
Brand Name: N/A
Power supply: DC 3.7V
1.4. AE used during the test
1.5. Description of test facility All measurement required was performed at laboratory of Shenzhen POCE Technology Co.,
Ltd. H Building, Hongfa Science and Technology Park, Tangtou, Shiyan, Bao’an District,
Shenzhen, China
Equipment type Model Manufacturer FCC Approval Remark
SHENZHEN POCE TECHNOLOGY CO., LTD. REPORT NO.:POCE16071933XRF
H Building, Hongfa science and Technology Park, Tangtou, Shiyan, Bao’an District, Shenzhen, China page 6 of 18 Tel: +86-755-29113252 Fax: +86-755-29113135 http://www. poce-cert.com
The test facility is recognized, certified, or accredited by the following organizations:
FCC – Registration No.: 222278
Shenzhen POCE Technology Co., Ltd. EMC Laboratory has been registered and fully
described in a report filed with the (FCC) Federal Communications Commission. The
acceptance letter from the FCC is maintained in our files. Registration 222278, June 08, 2010.
1.6. Test Standards The following Declaration of Conformity report of EUT is prepared in accordance with
47CFR Part 15(2014): Radio Frequency Device: Subpart B; Unintentional radiators Class B
ANSI C63.4(2009): Interim Standard for Methods of Measurement of Radio-Noise Emissions
from Low-Voltage Electrical and Electronic Equipment in the Range of 9KHz to 40GHz.
1.7. Test Summary
1.8. Measurement Uncertainty Item Uncertainty
1 Conducted Emission Test ±1.38dB 2 All emissions, radiated(<1G) ±4.68dB 3 All emissions, radiated(>1G) ±4.89dB
TEST ITEMS RESULT NOTE Disturbance voltage at a.c. mains terminal N/A
Radiated emission PASS
SHENZHEN POCE TECHNOLOGY CO., LTD. REPORT NO.:POCE16071933XRF
H Building, Hongfa science and Technology Park, Tangtou, Shiyan, Bao’an District, Shenzhen, China page 7 of 18 Tel: +86-755-29113252 Fax: +86-755-29113135 http://www. poce-cert.com
2. POWER LINE CONDUCTED MEASUREMENT
2.1. Test Equipment The following test equipments are used during the power line conducted measurement:
Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval
1. Test Receiver Rohde &
Schwarz
ESCI3 ID:1166.5950K03
-101431-Jq
Oct. 09, 2015 1 Year
2. L.I.S.N. Rohde &
Schwarz
ESH3-Z5 831.5518.52 Oct. 09, 2015 1 Year
3. Pulse Limiter SCHWARZ BECK VTSD 9561-F 9561-G071 Oct. 09, 2015 1 Year
4. RF Cable FUJIKURA RG-55/U LISN Cable Oct. 09, 2015 1 Year
2.2. Block Diagram of Test Setup 2.2.1.Block diagram of connection between the EUT and simulators
2.2.2.Block diagram of test setup
2.3. Power Line Conducted Emission Measurement Limits (Class B)
Limits dB(μV) Frequency
MHz Quasi-peak Level Average Level
0.15 ~ 0.50 66 ~ 56* 56 ~ 46*
0.50 ~ 5.00 56 46
5.00 ~ 30.00 60 50 Notes: 1. *Decreasing linearly with logarithm of frequency.
2. The lower limit shall apply at the transition frequencies.
SHENZHEN POCE TECHNOLOGY CO., LTD. REPORT NO.:POCE16071933XRF
H Building, Hongfa science and Technology Park, Tangtou, Shiyan, Bao’an District, Shenzhen, China page 8 of 18 Tel: +86-755-29113252 Fax: +86-755-29113135 http://www. poce-cert.com
2.4. Configuration of EUT on Measurement The following equipments are installed on Power Line Conducted Emission Measurement to
meet the commission requirement and operating regulations in a manner, which tends to
maximize its emission characteristics in a normal application.
EUT : Shenzhen Yihexin Technology Co., Ltd.
Model Number : B22
2.5. Operating Condition of EUT 2.5.1. Setup the EUT and simulator as shown as Section 2.2.
2.5.2. Turn on the power of all equipment.
2.5.3. Let the EUT work in test mode (Normal) and measure it.
2.6. Test Procedure The EUT system is connected to the power mains through a line impedance stabilization
network (L.I.S.N.). This provides 50ohm-coupling impedance for the EUT system. Please refer
the block diagram of the test setup and photographs. Both sides of AC line are checked to find
out the maximum conducted emission. In order to find the maximum emission levels, the
relative positions of equipment and all of the interface cables shall be changed according to
FCC/ANSI C63.4-2009 on Conducted Emission Measurement.
The bandwidth of test receiver (R & S ESCI 3) is set at 9KHz.
The frequency range from 150KHz to 30MHz is checked.
The test result is reported on Section 2.7.
2.7. Power Line Conducted Emission Measurement Results
N/A
SHENZHEN POCE TECHNOLOGY CO., LTD. REPORT NO.:POCE16071933XRF
H Building, Hongfa science and Technology Park, Tangtou, Shiyan, Bao’an District, Shenzhen, China page 9 of 18 Tel: +86-755-29113252 Fax: +86-755-29113135 http://www. poce-cert.com
3. RADIATED EMISSION MEASUREMENT
3.1. Test Equipment The following test equipments are used during the radiated emission measurement:
3.1.1. For Anechoic Chamber
Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval
1. Spectrum Analyzer Agilent E4408B CFG006 Oct. 09, 2015 1 Year
2. Test Receiver R&S ESCI3 ID:1166.5950K0
3-101431-Jq
Oct. 09, 2015 1 Year
3. Bilog Antenna Sunol Sciences Model JB6
Antenna A090414 Oct. 09, 2015 1 Year
4. 50 Coaxial Switch Anritsu Corp MP59B 6100237248 Oct. 09, 2015 1 Year
5. Horn Ant Schwarzbeck Model
DRH-118
A091114 Oct. 09, 2015 1 Year
6. Cable Schwarzbeck AK9513 ACRX1 Oct. 09, 2015 1 Year
7. Cable Rosenberger N/A FP2RX2 Oct. 09, 2015 1 Year
8. Cable Schwarzbeck AK9513 CRPX1 Oct. 09, 2015 1 Year
9. Cable Schwarzbeck AK9513 CRRX2 Oct. 09, 2015 1 Year
3.2. Block Diagram of Test Setup 3.2.1. Block diagram of connection between the EUT and simulators
3.2.2. Anechoic Chamber Test Setup Diagram
SHENZHEN POCE TECHNOLOGY CO., LTD. REPORT NO.:POCE16071933XRF
H Building, Hongfa science and Technology Park, Tangtou, Shiyan, Bao’an District, Shenzhen, China page 10 of 18 Tel: +86-755-29113252 Fax: +86-755-29113135 http://www. poce-cert.com
3.3. Radiated Emission Limit (Class B)
FIELD STRENGTHS LIMIT FREQUENCY
MHz
DISTANCE
Meters μV/m dB(μV)/m
30 ~ 88 3 100 40.0
88 ~ 216 3 150 43.5
216 ~ 960 3 200 46.0
960 ~ 1000 3 500 54.0 Remark:(1) Emission level (dB)μV = 20 log Emission level μV/m
(2) The smaller limit shall apply at the cross point between two frequency bands.
(3) Distance is the distance in meters between the measuring instrument, antenna and the
closest point of any part of the device or system.
3.4. EUT Configuration on Measurement The following equipment are installed on Radiated Emission Measurement to meet the
commission requirements and operating regulations in a manner which tends to maximize its
emission characteristics in normal application.
Shenzhen Yihexin Technology Co., Ltd.(EUT)
Model Number : B22
Serial Number : N/A
3.5. Operating Condition of EUT 3.5.1.Setup the EUT as shown in Section 3.2.
3.5.2.Let the EUT work in test mode (Normal) and measure it.
3.6. Test Procedure EUT and its simulators are placed on a turntable, which is 0.8 meter high above ground. The
turntable can rotate 360 degrees to determine the position of the maximum emission level. EUT
is set 3.0 meters away from the receiving antenna, which is mounted on an antenna tower. The
antenna can be moved up and down between 1.0 meter and 4 meters to find out the maximum
emission level. Broadband antenna (calibrated bilog antenna) is used as receiving antenna.
Both horizontal and vertical polarization of the antenna is set on measurement. In order to find
the maximum emission levels, all of the interface cables must be manipulated according to
ANSI C63.4-2009 on radiated emission measurement.
The bandwidth of the EMI test receiver (R&S ESCI 3) is set at 120KHz.
The frequency range from 30MHz to 1000MHz is investigated.
SHENZHEN POCE TECHNOLOGY CO., LTD. REPORT NO.:POCE16071933XRF
H Building, Hongfa science and Technology Park, Tangtou, Shiyan, Bao’an District, Shenzhen, China page 11 of 18 Tel: +86-755-29113252 Fax: +86-755-29113135 http://www. poce-cert.com
3.7. Radiated Emission Measurement Results
SHENZHEN POCE TECHNOLOGY CO., LTD. REPORT NO.:POCE16071933XRF
H Building, Hongfa science and Technology Park, Tangtou, Shiyan, Bao’an District, Shenzhen, China page 12 of 18 Tel: +86-755-29113252 Fax: +86-755-29113135 http://www. poce-cert.com
SHENZHEN POCE TECHNOLOGY CO., LTD. REPORT NO.:POCE16071933XRF
H Building, Hongfa science and Technology Park, Tangtou, Shiyan, Bao’an District, Shenzhen, China page 13 of 18 Tel: +86-755-29113252 Fax: +86-755-29113135 http://www. poce-cert.com
4. TEST SETUP PHOTO
SHENZHEN POCE TECHNOLOGY CO., LTD. REPORT NO.:POCE16071933XRF
H Building, Hongfa science and Technology Park, Tangtou, Shiyan, Bao’an District, Shenzhen, China page 14 of 18 Tel: +86-755-29113252 Fax: +86-755-29113135 http://www. poce-cert.com
FIGURE GENERAL APPEARANCE OF EUT
Fig.1
Fig.2
SHENZHEN POCE TECHNOLOGY CO., LTD. REPORT NO.:POCE16071933XRF
H Building, Hongfa science and Technology Park, Tangtou, Shiyan, Bao’an District, Shenzhen, China page 15 of 18 Tel: +86-755-29113252 Fax: +86-755-29113135 http://www. poce-cert.com
Fig.3
Fig.4
SHENZHEN POCE TECHNOLOGY CO., LTD. REPORT NO.:POCE16071933XRF
H Building, Hongfa science and Technology Park, Tangtou, Shiyan, Bao’an District, Shenzhen, China page 16 of 18 Tel: +86-755-29113252 Fax: +86-755-29113135 http://www. poce-cert.com
Fig.5
Fig.6
SHENZHEN POCE TECHNOLOGY CO., LTD. REPORT NO.:POCE16071933XRF
H Building, Hongfa science and Technology Park, Tangtou, Shiyan, Bao’an District, Shenzhen, China page 17 of 18 Tel: +86-755-29113252 Fax: +86-755-29113135 http://www. poce-cert.com
Fig. 7
Fig.8
SHENZHEN POCE TECHNOLOGY CO., LTD. REPORT NO.:POCE16071933XRF
H Building, Hongfa science and Technology Park, Tangtou, Shiyan, Bao’an District, Shenzhen, China page 18 of 18 Tel: +86-755-29113252 Fax: +86-755-29113135 http://www. poce-cert.com
Fig.9
Fig.10
*************************THE END OF REPORT***************************